overview 1/1 overvie€¦ · connect the network cable to the lan port on the srm ethernet torque...

28
Overview 1/1 Overview The SRM Ethernet Torque Analysis software is designed to display pedaling torque inputs in real time and provide the user with the ability to record and analyze data. Torque data is useful when working to determine optimum bike fit, the result of changes made to position, athlete pedaling dynamics, and when working to rehabilitate after injury. Data collected can be saved, reloaded, and exported for use in various other applications and formats.

Upload: others

Post on 19-Oct-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Overview 1/1 Overvie€¦ · Connect the network cable to the LAN port on the SRM Ethernet Torque Analysis Box and to your computer Software setup 1. Configure the network address

Overview 1/1Overview

The SRM Ethernet Torque Analysis software is designed to display pedaling torque inputs in real time and provide the user with the ability to record and analyze data.

Torque data is useful when working to determine optimum bike fit, the result of changes made to position, athlete pedaling dynamics, and when working to rehabilitate after injury.

Data collected can be saved, reloaded, and exported for use in various other applications and formats.

Page 2: Overview 1/1 Overvie€¦ · Connect the network cable to the LAN port on the SRM Ethernet Torque Analysis Box and to your computer Software setup 1. Configure the network address

Requirements 1/1

RequirementsSRM Ethernet Torque Analysis BoxSRM Powermeter with wired coil and sensor cablePC or laptop running either: MS Windows XP, Vista, or 7; Mac OSX 10.5 or higher; or Linux Kernel 2.6 or higher.Java Interpreter installed on the computerOne LAN port available on the computer

Page 3: Overview 1/1 Overvie€¦ · Connect the network cable to the LAN port on the SRM Ethernet Torque Analysis Box and to your computer Software setup 1. Configure the network address

SRM Ethernet Torque Analysis Box 1/2

SRM Ethernet Torque Analysis Box

Sensor: Analogic sensor cable connectionDigital: Digital sensor cable connectionCadence: Cadence LED, flash once a revolutionOn: Power LED, on when powered

Ethernet: RJ45 LAN connecion+5V DC: Power connection

Page 4: Overview 1/1 Overvie€¦ · Connect the network cable to the LAN port on the SRM Ethernet Torque Analysis Box and to your computer Software setup 1. Configure the network address

SRM Ethernet Torque Analysis Box 2/2

Ethernet: RJ45 LAN connecion+5V DC: Power connection

Note: Power delivery from USB port on a computer is not sufficient to run the SRM Ethernet Torque box. Please use the AC power supply.

Page 5: Overview 1/1 Overvie€¦ · Connect the network cable to the LAN port on the SRM Ethernet Torque Analysis Box and to your computer Software setup 1. Configure the network address

System setup 1/1

System setup

Hardware setup

1. Ensure current set-up of PowerMeter, including positioning of the sensor cable

2. Connect SRM Ethernet Torque Analysis Box to the sensor cable

When using 4-pin sensor cable from Powercontrol 4 Torque output, use the digital input port of the SRM Ethernet Torque boxWhen using 5-pin sensor cable, use the analog input port of the SRM Ethernet Torque box

3. Connect AC Power supply to the power input port of the SRM Ethernet Torque Analysis Box, check if power led (green color) is on (see troubleshooting for any problems)

4. Secure SRM Ethernet Torque box in stable position5. Start pedaling and check if the cadence led (amber color) is flashing

when the cadence magnet inside the PowerMeter passes the sensor (see troubleshooting for any problems)

6. Connect the network cable to the LAN port on the SRM Ethernet Torque Analysis Box and to your computer

Software setup

1. Configure the network address on your computer to the same subnetwork of SRM Ethernet Torque Analysis Box (see here for detail)

2. Download the software from SRM website3. Ensure you have Java installed on your computer otherwise download

from Java website4. Launch the SRM Torque Software5. When the software first runs, it will ask you to define a writable folder to

save the data. Select a folder.6. Main screen is now shown; go to Settings by clicking on the lower right

corner button or through the Options-Settings on the top menu and configure the program

7. Start pedaling, and check the connection indicator on the lower left corner of the screen: this indicator should be green, if not go to Log and check the messages

Page 6: Overview 1/1 Overvie€¦ · Connect the network cable to the LAN port on the SRM Ethernet Torque Analysis Box and to your computer Software setup 1. Configure the network address

Views 1/6Views

Main view

The majority of this view is used by a graph showing online data: the x-axis of this graph is measuring the Angle of revolution in degrees, and the y-axis is the Torque in Newton-metersThe left side of this view shows numerically the last revolution value for Power, Torque, and Cadence

The right side of this view has two buttons: Record and Reset; pressing the Record button begins recording revolutions, pressing the Reset button clears all stored data.The right side of this view also has an area to define the Automatic Stop preferences. Selecting

Page 7: Overview 1/1 Overvie€¦ · Connect the network cable to the LAN port on the SRM Ethernet Torque Analysis Box and to your computer Software setup 1. Configure the network address

Views 2/6

begins recording revolutions, pressing the Reset button clears all stored data.The right side of this view also has an area to define the Automatic Stop preferences. Selecting None will result in recording revolutions until stopped manually with the Stop button, selecting Revolutions will result in recording the specified number of revolutions entered and selecting Time will result in recording the specified seconds of time entered

The Notes area is for entering information specific to the revolution data that you record; any notes entered here will be displayed in the revolution table in the Analysis viewDirectly below the main graph, there is a field showing numerically the index of the revolution with the relative cadence and power

The bottom of the main view has a tracking feature which allows you to see specific angle and torque data as you mouse over the graph

Analysis view

The top part of this view contains a revolution table, showing data from all recorded revolutionsWhen you select a revolution, the relative profile is shown in the Analysis graph

Page 8: Overview 1/1 Overvie€¦ · Connect the network cable to the LAN port on the SRM Ethernet Torque Analysis Box and to your computer Software setup 1. Configure the network address

Views 3/6

Selecting multiple revolutions results in the graphical display of all revolutions (For windows operating system, this is done by pressing Ctrl-Click. When using Mac OS, this is done by pressing Commnand-Click)

The right side of this view has a "Data Operation" area; to export data, first select the output format (CSV, PNG, or PDF), then, pressing the "Export" button will export all selected revolutionsTo calculate the average graph of revolutions just select 2 or more revolutions and press the "Calculate Average" button

Page 9: Overview 1/1 Overvie€¦ · Connect the network cable to the LAN port on the SRM Ethernet Torque Analysis Box and to your computer Software setup 1. Configure the network address

Views 4/6

The "Save" button allows you to save all checked revolutions (see "Save" column in revolution table); the number shown on the "Save" button indicates the number of flagged revolutions. All files will be saved in the data folder defined in the "Settings-System" window. The naming format of the SRM Torque Analysis file (.sta) is: initials-YYYY.MM.DD HH.mm.SS where initials can be changed and the system automatically uses the user default data

The "Load" button allows you to open revolutions previously saved; press the "Load" button, select a file, then press "Load File" button (uncheck "Update Statistics" if you do not want the file to affect current statistics)

Pressing "Select File" allows you to Load another file; when all files are loaded, press "Close" to exit the window

Page 10: Overview 1/1 Overvie€¦ · Connect the network cable to the LAN port on the SRM Ethernet Torque Analysis Box and to your computer Software setup 1. Configure the network address

Views 5/6

The "Marker Info" area is used for reading measurements from the graph. First, select one or more revolutions, then click a starting point, followed by an ending point. The delta of these two points will be displayed in the "Marker Info" area, showing both "Angle" in degrees and "Torque" in Nm. The "Marker Color" button allows you to change the color of the lines used to display the marker. The "Delete Markers" button clears all markers

The menu in the lower right corner allows you to display the data in different torque values

Statistics view

The upper half of this view contains two histograms that show the Cadence and Power distribution for all recorded revolutions

Page 11: Overview 1/1 Overvie€¦ · Connect the network cable to the LAN port on the SRM Ethernet Torque Analysis Box and to your computer Software setup 1. Configure the network address

Views 6/6

The lower half of this view contains a scattergraph that shows the relationship bewteen Cadence and Power for all recorded revolutions

Log view

The Log view contains a complete listing of all relavent events that occured in the software during the current session

Connection informationSave messagesLoad messagesDevice statusError notificationsRecording events

Page 12: Overview 1/1 Overvie€¦ · Connect the network cable to the LAN port on the SRM Ethernet Torque Analysis Box and to your computer Software setup 1. Configure the network address

Settings 1/5

SettingsThe Settings window has 5 tabs:

1. The Graph tab allows you to adjust the number of simultaneous revolutions shown on the main graph, as well as select custom colors for each revolution by clicking on the color. The Add and Delete new revolution buttons allow you to vary the number of revolutions between 1 and 10. Checking the "Automatic Torque Scale" box will result in a self-adjusting y-axis for torque values. By leaving this box unchecked, you can manually select the maximum torque value shown on the y-axis of the main graph.

The User tab contains relavent information for all user profiles. The User profile drop-down box contains a list of all stored users and their Parameters are shown when selected.

Page 13: Overview 1/1 Overvie€¦ · Connect the network cable to the LAN port on the SRM Ethernet Torque Analysis Box and to your computer Software setup 1. Configure the network address

Settings 2/5

To change any parameters to a user, input the new value and click Apply modification button. To Delete a user, select user from drop-down box and press Delete user button. To create a new user, input a user name for the profile, and all the parameter information, then click "Add new user" button; the current user profile is shown in red. To change this, select a different user from the "User profile" drop-down box, and click "Use current user" button; the current user information will be updated. The parameters from the current user provide important information for the accuracy of the data being collected for each revolution, such as the weight and crank length. The status bar on the bottom of the window will provide notification for all actions done.

Page 14: Overview 1/1 Overvie€¦ · Connect the network cable to the LAN port on the SRM Ethernet Torque Analysis Box and to your computer Software setup 1. Configure the network address

Settings 3/5

done.

The PowerMeter tab is needed to change PowerMeter's parameters:

The zero offset value of the PowerMeterThe slope of the PowerMeterThe value where the revolution starts

Page 15: Overview 1/1 Overvie€¦ · Connect the network cable to the LAN port on the SRM Ethernet Torque Analysis Box and to your computer Software setup 1. Configure the network address

Settings 4/5

The Network tab allows to change all network parameter like ip address and port.

The System tab shows all network interfaces on your computer and is important when configuring your network address. Also, the destination folder for stored data is selectable in this tab.

Page 16: Overview 1/1 Overvie€¦ · Connect the network cable to the LAN port on the SRM Ethernet Torque Analysis Box and to your computer Software setup 1. Configure the network address

Settings 5/5

when configuring your network address. Also, the destination folder for stored data is selectable in this tab.

Page 17: Overview 1/1 Overvie€¦ · Connect the network cable to the LAN port on the SRM Ethernet Torque Analysis Box and to your computer Software setup 1. Configure the network address

Commands 1/1

Commands

RecordThe Record button allows you to register revolutions. Data is collected in the revolution table and is the source of the Statistics.

The stop recording process just press the relative "Stop" button.

ResetPressing the Reset button will delete all recorded revolutions. This will also result in the deletion of all Statistics.

Page 18: Overview 1/1 Overvie€¦ · Connect the network cable to the LAN port on the SRM Ethernet Torque Analysis Box and to your computer Software setup 1. Configure the network address

Commands 1/1

Utilities

SimulatorThe simulator is a part of the SRM Torque Analysis software that permits to simulate the revolutions; to enable this goe to "Utilitis - Simulator" menu and than press start. Make sure to select "Simulator" also in the "Network profile" on the settings menu.

Cadence BellThis option will enable a cadence signal for each revolution when the signal is triggered.

Page 19: Overview 1/1 Overvie€¦ · Connect the network cable to the LAN port on the SRM Ethernet Torque Analysis Box and to your computer Software setup 1. Configure the network address

Troubleshooting 1/2

Troubleshooting

Power LED doesn't switch onCheck the power supply and the power cable connection Cadence LED doesn't flash for each revolutionCheck the position of the sensor cable or see PowerMeter battery issues Power and Torque values shown on "Main" screen are not accurateEnsure the PowerMeter settings are correct: check the slope and the zero offset values on Settings-Powermeter window Candence value is visible but not accurateCheck the position of the sensor cable No connection between the computer and the SRM Ethernet Torque BoxCheck the network configuration on your computer, ensure the ip address is the same subnetwork of SRM Ethernet Torque Analysis box SRM Ethernet Torque Box's IP adress lostUse the DeviceInstaller Utility to find and setup a new ip adress The revolution graph is not in the right positionCheck the relative parameter on "PowerMeter profile" considering the activation point

Position of the sensor cable

Check position of sensor cable to ensure it is passing over the cadence switch at a distance in between 3 and 5 [mm].

Page 20: Overview 1/1 Overvie€¦ · Connect the network cable to the LAN port on the SRM Ethernet Torque Analysis Box and to your computer Software setup 1. Configure the network address

Troubleshooting 2/2

PowerMeter battery issues

The PowerMeter battery is not self-replaceable. You will need to send it to the Service Center for replacement. ATTEMPTING TO REPAIR IT YOURSELF WILL INVALIDATE THE WARRANTY, and could cause permanent damage to your PowerMeter. Battery life of the PowerMeter will vary between PowerMeters. General expectancy of wired systems:

DuraAce/FSA/track approximately 1500 hours of usePro and Amateur approximately 1000 hours of useCannondale/Specialized approximately 750 hours of use

General expectancy of wireless systems with ANT technology:

DuraAce/FSA/Pro approximately 1400 hours of useCannondale/Specialized approximately 700 hours of use

If the variance of your zero-offset begins to fluctuate more than normal and your hours of usage is in-line with the above, your battery likely needs to be replaced. Please download the Service Form and send your PowerMeter back to the Service Center for replacement.

Page 21: Overview 1/1 Overvie€¦ · Connect the network cable to the LAN port on the SRM Ethernet Torque Analysis Box and to your computer Software setup 1. Configure the network address

Activation point 1/1

Activation point

Changing the activation point for the revolution is necessary when you wish to view the revolution with a specific starting point.Your powermeter triggers cadence at the point where the reed switch inside the powermeter passes the sensor.To change the activation starting point for the torque revolution, you must first measure the angle in degrees of your sensor cable (see picture below).

This means the revolution starts at 42 degrees from the vertical position

If you want to have the revolutions started from 90 degrees just set the activation point to 48 (90-42=48).

Page 22: Overview 1/1 Overvie€¦ · Connect the network cable to the LAN port on the SRM Ethernet Torque Analysis Box and to your computer Software setup 1. Configure the network address

Network configuration 1/2

Network configuration

Check the SRM Ethernet Torque box ip address; this address is printed on the bottom of the outer case. See "Default IP adress" label.Choose a free and valid ip address on the same subnetwork of your computer: i.e. 192.168.0.10Configure the ip address

If you are using MS Windows Seven Press "Start" buttonOpen "Control Panel"Select "Network and Sharing Center"Click "View Network Connections"Right click on the connection you need to change (i.e. Lan) than "Properties"On "Network" tab double click on "Internet Protocol Version 4 (TCP/IPV4)"Insert the choosen IP address (see point 2.)If you are using Apple OSX Launch "System Preferences" from the Apple menu (or Spotlight)Click on the "Network" iconIn the lower right, click on the "Advanced" buttonIn the pulldown menu next to "Configure IPv4 "select "Manually"Insert the chosen ip address

Page 23: Overview 1/1 Overvie€¦ · Connect the network cable to the LAN port on the SRM Ethernet Torque Analysis Box and to your computer Software setup 1. Configure the network address

Network configuration 2/2

Page 24: Overview 1/1 Overvie€¦ · Connect the network cable to the LAN port on the SRM Ethernet Torque Analysis Box and to your computer Software setup 1. Configure the network address

DeviceInstaller Utility 1/3DeviceInstaller UtilityHow to change parameters on Lantronix onboard network bridge:

1. Download the latest version of DeviceInstaller from Lantronix® website (http://www.lantronix.com/device-networking/utilities-tools/device-installer.html)

2. Open the Lantronix Device Installer and click search to finde the network attached XPort device.

Click on the found device and select the Web Configuration Tab.Click Go to open a connection to the device. No User and Password.

Enter Serial Settings and change the parameters to the values in the picture than click OK.

Page 25: Overview 1/1 Overvie€¦ · Connect the network cable to the LAN port on the SRM Ethernet Torque Analysis Box and to your computer Software setup 1. Configure the network address

DeviceInstaller Utility 2/3

Enter Network and change the parameters to the values in the picture, than click OK.

Page 26: Overview 1/1 Overvie€¦ · Connect the network cable to the LAN port on the SRM Ethernet Torque Analysis Box and to your computer Software setup 1. Configure the network address

DeviceInstaller Utility 3/3

And now finally click Apply Settings.

Page 27: Overview 1/1 Overvie€¦ · Connect the network cable to the LAN port on the SRM Ethernet Torque Analysis Box and to your computer Software setup 1. Configure the network address

Table of symbols 1/2

Table of symbolsCommands

Start recording

Stop recording

Reset all revolution data

 Data operation

Export selected revolutions (you need to select at least one revolution to enable this button)

Save checked revolutions (you need to check at least one revolution to enable this button)

Load a SRM Torque Analysis file (.sta) which contains revolutions data

Makes the calculation of the average of the selected revoltions (you need to select at least two revolutions to enable this button)

 Settings

Add a new profile

Delete selected profile (this profile cannot be the default profile)

Makes selected profile as default

Applies modification

 

Page 28: Overview 1/1 Overvie€¦ · Connect the network cable to the LAN port on the SRM Ethernet Torque Analysis Box and to your computer Software setup 1. Configure the network address

Table of symbols 2/2 Simulator

Starts the simulator

Stops the simulator

 Message icons

Notifies a general message

Notifies a question message

Notifies an error message

 Device connection leds

Device correctly connected

Device not connected

Notifies a warning, click con the icon to be redirect on the log

 Help

Help request (the embedded manual will be open)