NVLAP LAB CODE 201011-0 Report No.: GZE140411-J3 Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0 Report Format Number STD/QR4909-A/2 Address8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com 1 / 17 LM-79-08 Test Report For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD (Brand Name: GI LED LIGHTING) 4th floor, building 2, Zone 2, Hong Hua Ling Industrial Park, Liu xian Block ,Nan Shan District, Shenzhen, China 518055 Outdoor Wall-Mounted Area Luminaires Model name(s): GI-WP09-CW Model Different: N/A Test & Report By: Review By: Sean Zhuo Engineer: Sean Zhuo Manager: Tommy Liang Date: May 5. 2014 Note: This report does not imply product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government.

Upload: ngodiep

Post on 07-Sep-2018

214 views

Category:

Documents


0 download

TRANSCRIPT

NVLAP LAB CODE 201011-0

Report No.: GZE140411-J3

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

1 / 17

LM-79-08 Test Report

For

GREEN INOVA LIGHTING TECHNOLOGY

(SHENZHEN) LTD

(Brand Name: GI LED LIGHTING)

4th floor, building 2, Zone 2, Hong Hua Ling Industrial Park,

Liu xian Block ,Nan Shan District,

Shenzhen, China 518055

Outdoor Wall-Mounted Area Luminaires

Model name(s): GI-WP09-CW

Model Different: N/A

Test & Report By: Review By:

Sean Zhuo

Engineer: Sean Zhuo Manager: Tommy Liang

Date: May 5. 2014

Note: This report does not imply product certification, approval, or endorsement by NVLAP, NIST, or

any agency of the Federal Government.

NVLAP LAB CODE 201011-0

Report No.: GZE140411-J3

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

2 / 17

U.S. Department of Energy

Lighting FactsTM

Uniform LM-79 Reporting Template

Laboratory Information:

Name of Test Laboratory Standard-Tech Co. Ltd

Date of Test Report May 5. 2014

Test Report No. GZE140411-J3

Laboratory Contact Name Tommy Liang

Product Information:

Organization Name GREEN INOVA LIGHTING TECHNOLOGY

(SHENZHEN) LTD

Brand Name GI LED LIGHTING

Model Number GI-WP09-CW

SKU (if available) N/A

Type of Luminaire

(for integral lamps, list base type and lamp type) Outdoor Wall-Mounted Area Luminaires

Luminaire Aperture (for downlights) -- in.

Luminaire Length -- mm

Luminaires Width -- mm

Number of Units (modular products) N/A s

Electrical Measurements:

Integrating Sphere

Output

Goniophotometer

Output

Input Wattage -- 89.09 W

Input Current -- 0.7470 A

Input Voltage (ac) -- 120 V

Power Factor -- 0.9937

Off-State Power -- 0 W

Photometric Characteristics

Total Initial Lumen Output -- 7070 lm

Initial Lumen Efficacy -- 79.36 lm/w

Correlated color temperature / CCT 5514 -- K

Color rendering index / CRI 72 --

R9 Value 0 --

Duv 0.0028 --

Luminous Intensity Distribution

Center beam candlepower (if applicable)

-----

11491 cd

Beam angle (if applicable) 31.9 °

Zonal lumens in the 0°-60° zone 88.6 %

Zonal lumens in the 60°-90° zone 9.0 %

Zonal lumens in the 90°-120° zone 1.9 %

Zonal lumens in the 120°-180° zone 0.5 %

NVLAP LAB CODE 201011-0

Report No.: GZE140411-J3

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

3 / 17

Test Specifications:

Date of Receipt : April 17.2014

Date of Test : April 24.2014

Test item : Total Luminous Flux, Luminous Distribution Intensity, Luminous

Efficacy, Correlated Color Temperature, Color Rendering Index,

Chromaticity Coordinate, Electrical parameters

Reference Standard IES LM-79-2008 Electrical and Photometric Measurements of Solid-State

Lighting Products

ANSI C78.377-2008 Specifications for the Chromaticity of Solid State

Lighting Products

CIE 13.3-1995 Method of Measuring and Specifying Colour Rendering

Properties of Light Sources

CIE 15-2004 Technical Report Colorimetry

IESNA LM-16-93 Practical Guide to Colorimetry of Light Source

IESNA TM-16-05 Technical Memorandum on Light Emitting Diode (LED)

Sources and Systems

Reference Work

Instruction

QD25

Test Methods

1. Photometric and Electrical measurements – Light Distribution Method:

Photometric parameters were measured using the goniophotometer and software. The ambient

temperature shall be maintained at 25° C ± 1° C, measured at a point not more than 1 m from the

sample and at the same height as the sample. The sample was operated at 347 Volts AC, 60Hz. It was

stabilized before measurement was made. Luminous flux, luminaire efficacy, zonal lumen were

calculated from the software taken at 1° vertical intervals and 22.5° horizontal intervals.

2. Photometric and Electrical Measurements – Integrating Sphere Method:

Photometric parameters were measured using an integrating sphere, a spectroradiometer and software.

The ambient temperature condition inside the sphere was maintained at 25º C ± 1º C. The sample

measurements were made using a spectroradiometer connected by a fiber optic cable and detector

through the detector port of the integrating sphere. The sample was operated at 347 Volts AC, 60Hz. It

was stabilized before measurement was made. Chromaticity coordinates, correlated color temperature

and color rendering index were calculated from the spectral radiant flux measurements taken at least 5

nm intervals over the range of 380 to 780 nm.

NVLAP LAB CODE 201011-0

Report No.: GZE140411-J3

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

4 / 17

1. Product Information:

Brand Name GI LED LIGHTING

Model Number GI-WP09-CW

Luminaire Type Outdoor Wall-Mounted Area Luminaires

Rated Voltage / Frequency 100 ~ 277 Vac, 50/60 Hz

Nominal Power 90W

Rated Initial Lamp Lumen --

Declared CCT 5500K

LED Manufacturer CREE

LED Model XB-D

Sample Receipt Date April 30.2014

Sample Number 140411-20

Photo

NVLAP LAB CODE 201011-0

Report No.: GZE140411-J3

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

5 / 17

2.2 Electrical, Photometric and Chromaticity Measurements

(Refer to Work Instruction QD25)

IES LM-79 2008

Test date 2014-05-04 Test Ambient: 25.2 º C

Test Orientation As intended Stabilization Time (min) 90

Model Number GI-WP09-CW

Electrical Measurement:

Sample No. Voltage (Vac) Frequency (Hz ) Current (A) Power (W) Power Factor THD %

140411-20 120 60 0.7470 89.09 0.9937 8.9

277 60 0.3373 89.66 0.9596 9.6

Sphere-Spectroradiometer Method:

Parameter Result Special Color Rendering Indices

Test Voltage (V) 120 R1 71 R9 0

Frequency (Hz) 60 R2 75 R10 39

Color Rendering Index (CRI) 72.0 R3 76 R11 72

R9 0 R4 74 R12 44

CCT (K) 5514 R5 72 R13 70

Chromaticity (x, y) x=0.3321 y=0.3463 R6 66 R14 86

Chromaticity (u’, v’) u'=0.2047 v'=0.4801 R7 80 R15 66

Duv 0.0028 R8 62 -- --

Total Luminous (lm) 7070

Luminous Efficacy (lm/W) 79.36

Goniophotometer Method:

Parameter Result

Test Voltage (V) 120

Frequency (Hz) 60

Total Luminous (lm) 6052.6

Luminous Efficacy (lm/W) 68.72

Beam Angle° 39.5

Center Beam Candle Power (cd) 5313

S/MH(C0/180) 0.74

S/MH(C90/270) 1.01

NVLAP LAB CODE 201011-0

Report No.: GZE140411-J3

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

6 / 17

Spectral Power Distribution

Spectral Power Distribution:

NVLAP LAB CODE 201011-0

Report No.: GZE140411-J3

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

7 / 17

Chromaticity Diagram

NVLAP LAB CODE 201011-0

Report No.: GZE140411-J3

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

8 / 17

Zonal Lumen Tabulation

Zonal Lumen Summary

Zone Lumens % Lamp % Luminaire

0-30 4,103.6 57.9% 57.9%

0-40 5,135.2 72.5% 72.5%

0-60 6,275.8 88.6% 88.6%

60-90 639.2 9% 9%

70-100 353.5 5% 5%

90-120 132.0 1.9% 1.9%

0-90 6,915.0 97.6% 97.6%

90-180 168.9 2.4% 2.4%

0-180 7,083.8 100% 100%

Lumens Per Zone

Zone Lumens % Total Zone Lumens % Total

0-10 816.4 11.5% 90-100 52.1 0.7%

10-20 1,725.3 24.4% 100-110 47.6 0.7%

20-30 1,561.8 22.0% 110-120 32.4 0.5%

30-40 1,031.6 14.6% 120-130 16.3 0.2%

40-50 672.6 9.5% 130-140 7.1 0.1%

50-60 468.0 6.6% 140-150 3.8 0.1%

60-70 337.7 4.8% 150-160 4.0 0.1%

70-80 201.0 2.8% 160-170 3.9 0.1%

80-90 100.4 1.4% 170-180 1.7 0%

NVLAP LAB CODE 201011-0

Report No.: GZE140411-J3

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

9 / 17

Photometric Data

Illuminance Plots

NVLAP LAB CODE 201011-0

Report No.: GZE140411-J3

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

10 / 17

ISOCANDELA DIAGRAM

ISOLUX DIAGRAM

NVLAP LAB CODE 201011-0

Report No.: GZE140411-J3

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

11 / 17

Candela Table - Type C

0 22.5 45 67.5 90 112.5 135 157.5 180 202.5 225 247.5 270 292.5 315 337.5 360

0 9485 9485 9485 9485 9485 9485 9485 9485 9485 9485 9485 9485 9485 9485 9485 9485 9485

1 8653 8747 8971 9250 9484 9711 9855 9929 9902 9861 9723 9572 9367 9097 8823 8661 8653

2 7958 8050 8313 8880 9435 9785 10094 10343 10355 10192 9917 9595 9241 8701 8226 7997 7958

3 7566 7578 7794 8493 9401 9908 10313 10731 10857 10597 10138 9579 9127 8302 7743 7553 7566

4 7337 7264 7487 8101 9271 10007 10639 11077 11280 10972 10350 9559 9049 7968 7391 7318 7337

5 7128 7093 7229 7715 9091 9997 10875 11293 11481 11143 10544 9654 8870 7632 7173 7123 7128

6 6643 6760 7038 7437 9004 10044 11007 11352 11406 11108 10622 9516 8533 7247 7015 6731 6643

7 5917 6182 6890 7251 8924 10091 10985 11341 11425 10969 10450 9256 8230 6911 6731 6115 5917

8 5442 5646 6596 7073 8767 10074 10905 11290 11319 10855 10105 8969 7888 6630 6320 5558 5442

9 5141 5298 6078 6820 8461 9960 10811 11063 11058 10622 9770 8729 7486 6387 5834 5179 5141

10 4990 4980 5539 6561 8166 9718 10672 10710 10837 10328 9430 8353 7066 6140 5339 4929 4990

11 4856 4794 5158 6364 7846 9432 10353 10444 10669 10038 9092 7850 6650 5835 4961 4789 4856

12 4643 4706 4886 6154 7553 9141 9954 10255 10542 9839 8653 7301 6196 5456 4680 4733 4643

13 4462 4563 4617 5941 7299 8877 9478 10050 10193 9611 8099 6765 5775 5104 4447 4601 4462

14 4340 4363 4430 5657 6911 8524 9090 9677 9706 9165 7613 6295 5372 4802 4274 4449 4340

15 4172 4154 4356 5293 6538 8001 8782 9217 9321 8641 7184 5862 5013 4490 4168 4239 4172

16 4096 3967 4259 4943 6239 7524 8530 8871 9159 8182 6898 5515 4704 4155 4055 4003 4096

17 4028 3883 4048 4625 5848 7088 8151 8681 8877 7889 6506 5235 4386 3874 3862 3809 4028

18 3848 3814 3817 4324 5461 6658 7701 8397 8517 7622 6088 4872 4062 3593 3590 3691 3848

19 3595 3670 3570 3993 5082 6137 7169 8042 8088 7220 5663 4562 3734 3323 3308 3520 3595

20 3471 3436 3368 3684 4746 5627 6691 7630 7626 6867 5247 4211 3440 3086 3073 3260 3471

21 3362 3223 3191 3457 4404 5135 6327 7160 7300 6431 4947 3838 3198 2879 2871 3053 3362

22 3087 3095 3035 3274 4066 4773 6004 6752 7121 6002 4726 3528 2973 2689 2699 2937 3087

23 2782 2926 2919 3061 3758 4437 5715 6446 6841 5718 4468 3290 2741 2498 2548 2734 2782

24 2524 2666 2814 2870 3494 4085 5364 6145 6459 5420 4167 3052 2521 2325 2401 2458 2524

25 2295 2395 2664 2701 3234 3794 4929 5781 6015 5094 3892 2815 2348 2169 2249 2225 2295

26 2021 2189 2482 2548 2974 3525 4529 5413 5709 4696 3577 2612 2163 2040 2074 2047 2021

27 1793 1972 2312 2408 2715 3267 4154 5092 5452 4318 3294 2439 2001 1926 1913 1846 1793

28 1618 1751 2162 2274 2516 3008 3851 4798 5242 4044 3010 2256 1838 1802 1790 1651 1618

29 1506 1624 2015 2129 2353 2750 3613 4518 4877 3801 2729 2057 1678 1686 1637 1514 1506

NVLAP LAB CODE 201011-0

Report No.: GZE140411-J3

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

12 / 17

30 1396 1498 1857 1991 2169 2489 3342 4289 4497 3589 2528 1860 1551 1581 1530 1377 1396

31 1319 1373 1694 1897 1967 2283 3071 4010 4195 3322 2317 1702 1425 1477 1424 1274 1319

32 1277 1269 1577 1797 1813 2139 2801 3712 3961 3055 2113 1573 1298 1373 1312 1188 1277

33 1238 1200 1461 1677 1670 1972 2543 3463 3725 2789 1929 1454 1198 1285 1217 1136 1238

34 1185 1165 1345 1579 1543 1799 2327 3232 3463 2608 1779 1352 1111 1202 1121 1103 1185

35 1144 1120 1234 1481 1442 1651 2132 3001 3229 2445 1644 1255 1031 1125 1037 1060 1144

36 1098 1080 1141 1383 1338 1532 1956 2770 2995 2261 1509 1154 966 1056 973 1024 1098

37 1058 1039 1069 1294 1240 1417 1806 2550 2761 2090 1392 1072 904 995 920 995 1058

38 1016 1007 1012 1217 1159 1312 1670 2367 2542 1933 1286 997 849 946 873 954 1016

39 975 980 961 1145 1097 1200 1535 2191 2326 1784 1179 931 804 903 843 917 975

40 936 953 921 1082 1034 1095 1410 2019 2135 1652 1093 871 765 866 818 887 936

41 905 921 883 1034 979 1020 1294 1861 1966 1533 1006 817 726 833 795 857 905

42 877 891 855 985 925 957 1201 1712 1810 1428 932 767 693 800 776 830 877

43 848 864 831 929 874 899 1111 1574 1662 1326 862 723 667 764 758 805 848

44 822 835 809 885 835 838 1021 1453 1514 1226 795 682 651 729 745 779 822

45 799 808 789 842 799 778 935 1340 1378 1131 734 641 629 695 732 758 799

46 772 783 767 797 756 720 861 1237 1256 1038 684 599 603 664 717 739 772

47 751 760 752 757 718 669 793 1138 1144 947 637 563 582 635 705 722 751

48 737 737 731 721 686 629 730 1039 1050 864 594 532 560 606 692 706 737

49 719 716 708 686 660 597 672 943 971 790 551 506 541 583 676 690 719

50 702 698 685 651 639 564 619 857 901 722 511 483 525 562 661 676 702

51 681 678 663 623 616 531 572 783 838 663 474 457 511 539 648 662 681

52 660 663 642 596 590 499 531 715 783 612 440 433 503 521 632 647 660

53 645 649 621 569 566 468 495 659 731 567 410 412 495 502 619 633 645

54 633 631 602 545 545 440 460 608 682 526 384 393 490 488 606 618 633

55 607 616 583 525 526 418 427 565 637 489 359 376 485 473 593 599 607

56 594 597 565 506 510 396 396 528 593 456 336 358 483 461 577 583 594

57 578 577 546 489 496 375 368 493 552 426 315 341 479 450 563 569 578

58 551 558 528 474 482 356 344 462 513 400 295 325 472 440 550 552 551

59 541 542 512 459 469 337 322 431 481 375 275 311 465 434 534 534 541

60 520 525 497 444 457 319 302 403 447 352 257 297 457 425 519 516 520

61 498 510 480 433 448 304 282 376 415 328 239 284 449 417 500 499 498

NVLAP LAB CODE 201011-0

Report No.: GZE140411-J3

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

13 / 17

62 482 492 462 421 440 289 264 348 388 304 223 270 438 406 483 486 482

63 473 474 445 409 433 275 245 326 367 285 208 256 424 396 466 473 473

64 456 458 429 398 423 262 227 305 346 267 194 243 407 386 450 455 456

65 441 444 413 386 412 249 212 286 327 251 181 229 386 371 437 441 441

66 427 432 398 373 400 236 198 272 307 237 170 215 360 354 421 427 427

67 412 418 381 361 383 223 185 257 290 225 160 200 330 330 405 412 412

68 399 403 367 347 365 210 173 241 270 212 150 184 296 307 386 397 399

69 387 390 353 330 344 197 160 227 254 199 140 169 262 284 369 385 387

70 375 377 339 311 320 184 150 214 240 186 131 154 229 261 352 370 375

71 359 364 323 291 292 172 141 202 224 175 124 139 195 237 334 355 359

72 346 351 309 268 263 159 133 189 211 166 118 125 165 215 315 343 346

73 334 339 293 246 230 146 126 176 200 156 112 112 140 194 295 330 334

74 324 326 277 222 199 135 118 166 189 147 105 102 118 175 275 316 324

75 316 313 262 200 169 123 111 158 179 139 99 92 100 157 256 304 316

76 308 301 247 179 142 113 105 150 173 132 94 83 85 142 234 292 308

77 299 290 233 161 118 102 100 142 169 125 89 74 74 131 213 281 299

78 289 279 219 145 97 93 95 134 167 120 84 67 66 123 192 270 289

79 278 269 204 131 81 84 89 126 164 115 79 60 61 116 170 259 278

80 269 258 188 119 69 75 84 120 163 111 74 54 58 109 147 247 269

81 260 246 170 108 59 67 79 115 162 107 70 49 55 100 128 234 260

82 250 233 150 98 52 60 75 111 160 103 65 44 51 91 113 219 250

83 233 219 132 89 47 54 70 108 155 100 61 40 46 82 102 197 233

84 199 197 115 81 43 48 65 104 150 96 56 36 41 75 92 163 199

85 170 162 103 74 40 43 60 101 143 92 51 33 35 69 88 136 170

86 146 134 92 67 36 38 55 97 137 87 47 30 30 66 90 115 146

87 127 112 86 62 31 34 51 92 128 83 43 27 25 64 95 100 127

88 123 97 88 59 27 31 46 86 119 78 39 25 21 61 96 100 123

89 127 99 93 58 22 28 41 81 109 72 34 23 18 58 94 102 127

90 123 100 94 56 19 25 36 74 99 66 29 20 16 55 92 101 123

91 113 97 93 54 16 22 31 59 82 43 24 18 14 52 88 96 113

92 102 93 90 52 15 20 26 13 15 4 18 16 12 49 86 93 102

93 102 93 87 49 14 17 19 1 1 1 10 14 11 46 83 102 102

NVLAP LAB CODE 201011-0

Report No.: GZE140411-J3

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

14 / 17

94 119 103 84 46 12 15 10 2 1 2 6 13 10 43 83 114 119

95 137 115 83 43 11 13 5 25 20 25 4 11 9 41 83 126 137

96 157 126 83 40 10 11 3 26 32 20 3 11 9 39 84 137 157

97 173 137 84 38 10 11 3 17 22 9 3 10 9 39 85 142 173

98 178 139 86 37 10 11 3 7 12 1 3 10 9 38 86 140 178

99 175 136 88 37 10 11 3 1 1 1 4 10 10 38 87 137 175

100 171 133 89 38 11 11 3 1 1 1 4 11 11 38 88 134 171

101 168 129 90 39 12 12 3 1 1 1 4 11 12 39 88 131 168

102 164 126 90 41 13 12 3 1 1 1 4 11 13 40 88 128 164

103 161 123 90 44 16 13 4 1 1 1 4 11 15 40 87 125 161

104 157 121 88 47 18 13 4 1 1 1 4 12 16 42 85 122 157

105 154 118 86 49 20 14 4 1 1 1 5 12 18 42 83 119 154

106 152 115 85 51 23 15 4 1 1 1 5 12 19 43 81 116 152

107 147 112 82 52 25 15 4 1 1 1 5 12 20 43 78 114 147

108 142 109 79 53 26 15 4 1 2 1 5 12 20 43 75 111 142

109 134 106 76 53 28 15 4 1 2 1 5 12 21 42 72 108 134

110 126 102 73 53 28 15 4 1 2 1 4 12 21 41 68 104 126

111 118 98 70 51 28 15 4 1 2 1 4 11 21 40 65 100 118

112 110 93 66 49 28 14 4 1 2 1 4 11 21 38 62 95 110

113 103 88 63 47 27 13 4 1 2 1 4 10 20 36 59 90 103

114 98 83 59 45 27 13 3 1 2 1 4 10 20 34 56 85 98

115 94 79 56 43 26 12 3 1 2 1 3 10 19 32 54 81 94

116 90 75 54 40 25 11 3 1 2 1 3 9 18 30 52 77 90

117 87 71 51 38 24 10 3 1 2 2 3 9 17 28 49 73 87

118 80 68 49 36 23 10 3 1 2 2 3 8 16 27 47 70 80

119 69 65 47 33 22 9 2 1 2 2 3 8 16 25 46 67 69

120 56 63 45 31 21 9 2 1 2 2 3 7 15 23 44 64 56

121 47 60 43 29 19 8 2 1 2 2 2 7 14 21 42 61 47

122 40 57 41 26 18 7 2 1 2 2 2 7 13 20 40 57 40

123 31 54 38 24 17 7 2 1 2 2 2 6 12 18 37 54 31

124 40 50 36 22 16 6 2 1 2 2 2 6 12 17 35 50 40

125 50 46 33 20 14 6 2 1 2 2 2 6 11 16 33 47 50

NVLAP LAB CODE 201011-0

Report No.: GZE140411-J3

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

15 / 17

126 48 43 31 18 13 6 2 2 2 2 2 5 10 15 31 44 48

127 47 40 28 16 12 5 2 2 2 2 2 5 10 14 28 42 47

128 45 38 26 15 11 5 2 2 2 2 2 5 9 13 26 39 45

129 43 36 24 14 10 5 2 2 2 2 2 5 8 12 24 37 43

130 41 34 22 13 9 4 2 2 2 2 2 4 8 11 22 35 41

131 39 32 20 12 9 4 2 2 2 2 2 4 7 10 20 33 39

132 37 30 17 11 8 4 2 2 2 2 2 4 7 10 18 31 37

133 35 28 15 10 8 4 2 2 2 2 2 4 7 9 16 28 35

134 33 25 13 9 7 4 2 2 2 2 2 4 6 9 14 25 33

135 31 21 11 9 7 4 2 2 2 2 2 4 6 8 12 21 31

136 28 16 9 8 6 3 2 2 2 2 2 4 6 8 10 16 28

137 21 13 7 7 6 3 2 2 3 2 2 4 6 7 8 14 21

138 14 14 7 7 6 3 2 2 3 3 3 4 5 7 7 15 14

139 6 16 7 7 6 3 2 3 3 3 3 4 5 7 7 17 6

140 11 15 7 6 5 3 2 3 3 3 3 4 5 6 7 15 11

141 18 13 7 6 5 3 3 3 3 3 3 4 5 6 7 13 18

142 18 11 7 6 5 3 3 3 4 4 3 4 5 6 7 11 18

143 16 9 7 6 5 3 3 3 4 4 4 4 5 6 7 10 16

144 14 7 7 6 5 4 3 3 4 4 4 4 4 6 7 8 14

145 12 6 7 6 6 4 4 4 4 4 4 4 4 6 7 7 12

146 10 6 7 6 6 4 4 4 5 4 4 4 4 6 8 7 10

147 9 7 7 6 6 4 4 4 5 5 5 5 4 6 8 8 9

148 9 8 7 6 6 4 4 4 5 5 5 5 4 6 8 8 9

149 10 8 8 6 6 4 5 5 5 5 5 5 4 7 9 9 10

150 10 9 8 6 6 5 5 5 5 5 5 6 4 7 9 9 10

151 11 9 9 6 6 5 6 6 5 6 6 6 4 7 9 10 11

152 12 10 9 6 6 5 6 6 6 6 6 7 5 8 10 11 12

153 12 11 10 7 7 5 7 6 6 6 6 7 5 8 10 11 12

154 13 11 10 7 7 6 7 6 6 6 7 8 5 9 11 12 13

155 13 12 10 8 8 7 8 7 6 7 7 8 6 9 11 12 13

156 14 12 11 8 8 7 8 7 7 7 8 9 6 10 12 13 14

157 15 13 12 9 9 8 9 8 7 8 8 9 7 10 12 14 15

NVLAP LAB CODE 201011-0

Report No.: GZE140411-J3

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

16 / 17

158 15 14 12 9 10 8 9 8 7 8 9 10 7 10 13 14 15

159 16 14 13 10 10 9 10 9 8 9 9 10 8 11 14 15 16

160 16 15 14 10 11 10 10 9 9 9 10 11 8 11 14 15 16

161 16 15 14 11 11 10 11 10 9 10 10 12 9 12 15 15 16

162 17 15 15 12 12 11 11 11 9 10 11 12 10 12 15 15 17

163 17 16 16 12 13 12 12 11 10 11 11 13 10 13 16 16 17

164 17 16 16 13 13 13 13 12 10 11 12 13 10 13 16 16 17

165 18 17 17 14 14 13 13 13 11 12 13 14 11 14 16 18 18

166 19 18 18 14 15 14 14 14 12 12 14 14 12 14 17 18 19

167 20 19 18 15 15 15 14 15 14 13 14 15 12 15 18 19 20

168 20 19 18 15 16 15 15 16 15 15 15 16 12 15 18 19 20

169 21 19 19 16 16 15 16 16 16 16 16 17 13 15 18 19 21

170 21 19 19 16 16 16 16 17 17 17 17 17 13 16 18 19 21

171 22 19 19 17 16 16 17 18 18 18 17 18 14 16 19 19 22

172 22 19 19 17 16 16 17 19 19 19 18 19 14 16 19 19 22

173 22 19 19 17 16 16 18 19 19 20 18 19 14 17 19 19 22

174 22 20 20 18 17 17 18 19 20 20 19 19 15 17 19 20 22

175 23 20 20 18 17 17 18 19 20 21 19 19 15 18 19 20 23

176 22 20 20 18 17 17 18 19 20 21 19 19 16 18 20 20 22

177 22 20 20 18 17 13 18 19 20 21 19 19 16 18 20 20 22

178 22 19 20 18 17 17 17 19 20 21 18 19 16 18 20 20 22

179 21 19 20 18 17 17 17 19 19 20 18 19 16 18 20 20 21

180 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20

NVLAP LAB CODE 201011-0

Report No.: GZE140411-J3

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

17 / 17

3. Test Equipment

Equipment ID Equipment Name Last Calibration Date Next Calibration Date

ST-R-336 2 meter Integrating Sphere 2013-07-08 2014-07-07

ST-R-331 Spectral analysis system HAAS-2000 2013-06-21 2014-06-20

D204 Standard Lamp 2013-06-28 2014-06-27

PF2010 Power Meter for Integrating Sphere 2013-06-20 2014-06-19

EE-09 Goniophotometer system 2013-06-21 2014-06-20

D908S Standard Lamp 2013-07-05 2014-07-04

PF210 Power Meter for Goniophotometer 2013-06-20 2014-06-19

ST-R-181A Temperature Tester 2013-08-14 2014-08-13