our mission achieve the lowest environmental impact...low environmental impact, r-32 refrigerant gwp...

56
Introducing the new Sky Air A-series with ultra-efficient Bluevolution R-32 technology Our mission Achieve the lowest environmental impact

Upload: others

Post on 16-Sep-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

Introducing the new Sky Air A-series with ultra-efficient Bluevolution R-32 technology

Our mission

Achieve the lowest environmental impact

Page 2: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

2

The new Sky Air with R-32 delivers future proofed, best-in-class climate control.

Page 3: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

3

Geared for comfort Intuitive online control

Variable Refrigerant Temperature for optimal comfort

Tailored to your customers’ needs

Great design flexibility, making planning easier

More compact

Quieter

Extended operating range in all climate conditions

Help is at hand, installer benefits

Faster and easier installation and usability

Quick & reliable replacement

R-32 is an industry revolution. Be part of it. › R-32 is far more environmentally friendly than previous refrigerants

› Daikin leads the market with R-32 developments › First full light commercial range with R-32 in the market

Discover the

Daikin at the heart Unique Daikin technologies

Exceptionally low running costs, SEER up to 8.02

Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A

Equipped with tested and trusted Daikin technology

Page 4: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

4

Geared for comfort

Page 5: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

5

Unrivalled comfortWith the highest energy efficiencies, the Sky Air A-series uses Daikin Variable Refrigerant Technology to optimise comfort and flexibility to meet each customers’ needs. › Eliminates cold drafts › Weather dependent setting › Quiet outdoor units

› R-32 Global Warming Potential (GWP) is 68% lower than the industry standard R-410A

› Highest efficiency (SEER up to 8.02) in the market › Does not require yearly refrigerant containment checks, which reduces maintenance costs

› 16% less refrigerant charge

Online Controller

› Simple control from your smartphone › Control your device at anytime from anywhere › For single shop control › 3rd party products and services integration via IFTTT

From one to ∞ sites

CustomerInstaller/

technical manager

LOCAL CONTROL

DAIKIN CLOUD SERVICE

App ControlWhether you’re a small or large commercial business, our product range provides the solution to meet your needs.

Unique and most extended indoor unit range on the market › Top flexibility › Up to 50 different indoor unit options › Intelligent sensors › Auto cleaning options › Quiet units

Achieving the lowest

environmental impactEurope’s first light commercial system using R-32 refrigerant

Tablet

› User-friendly touch screen to centrally control your A/C and alarms

› Connects to the Daikin Cloud Service › Built for multi-site control and monitoring › Installers and technical managers receive alarm so they can provide remote assistance

› IFTTT is a solution that connects compatible 3rd party products and services (smart meters, lights, thermostats, ...), so they work best for you.

Page 6: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

6

Flexible to design Making planning easier

Page 7: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

7

New replacement technology A quicker, easier and more reliable approach when replacing existing systems

› Reduces any potential disruption and results in a system that significantly reduces energy consumption and bills for customers

› Hepta filtration ensures reliable operation without the need for pipe cleaning

› Cost and time effective solution, as the indoor and outdoor units only need be to changed. while keeping the pipe-work

The new Sky Air A-series, built for any Sky Air application

990 mm770 mm

! Replace indoor and outdoor units Replace any old system (Daikin and other manufacturers)

✓ Reuse existing piping and wiring

52°C DB-20C° DB 52°C DB 15.5°C WB-20C° WB

Push buttonon the PCB

R410-A

Kan niet aders dan met gradient, want vloeistof warmt op en koelt af...

1 v/d 2 kiezen

naam op gas�es eventueel vervangen door echt logo

even checken in de infographics map: ik denk dat er een tekening van een VRV bestaat

even checken in de infographics map: ik denk dat er een tekening van een VRV bestaat

foto in crkeltje zou ik behouden

Push buttonon the PCB

R410-A

Kan niet aders dan met gradient, want vloeistof warmt op en koelt af...

1 v/d 2 kiezen

naam op gas�es eventueel vervangen door echt logo

even checken in de infographics map: ik denk dat er een tekening van een VRV bestaat

even checken in de infographics map: ik denk dat er een tekening van een VRV bestaat

foto in crkeltje zou ik behouden

Lighter and more compact units for easy installation. Unique single fan range up to 14 kW

Full range below 1m in height!

Increased piping length up to 85m

Widest operation range › Cooling operation from -20°C to 52°C › Heating operation down to -20°C

Page 8: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

8

Help is at hand

Page 9: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

9

Faster installation with up to 40m pre-charged pipe

› Up to 60% of applications can be installed without additional refrigerant charge

Redesigned pivoting front plate for easy access to vital system components

New 7-segment display to view errors and systems settings

Guaranteed reliable performance in all weather conditions

› New refrigerant passes Lower part of the outdoor heat exchanger and drain holes are kept completely open and free of ice allowing ice water to evacuate perfectly, eliminating all risk of ice build-up.

› Refrigerant cooled PCB’s Reliable and stable cooling, independent from outdoor conditions

Integrated leak-check function reduces on-site checks and improves reliability

Benefits for installers

bottom plate refrigerant pass

Time

Tem

pera

ture

aro

und

El. B

ox

Daikin

Others

Reliable refrigerant cooled PCB’s

Page 10: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

10

Daikin at the heartUnique Daikin technologies

Page 11: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

11

A future-proof solution,

Daikin Sky Air A-series uses patented Daikin technology at the heart of the system

Jigsaw curved propeller

› Curved discharge grill and Jigsaw curved propeller for minimal turbulence and optimal airflow

Bottom plate and heat exchanger refrigerant pass

Daikin swing compressor

Integration of main moving parts into one component

› No abrasion or friction › No refrigerant leakages › No temperature rise because of leakage

› High compressor efficiencies › Increased system life span

Refrigerant cooled PCB

3-row heat exchanger › Unqiue 3-row heat exchanger to allow compact casing up to 14 kW

UNIQUE &

PATENTED TECHNOLOGY

› Drain holes are kept ice free

› Guaranteed operation down to -20°C

Page 12: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

12

Outdoor units products overview

Outdoor units

The three new leaders

Pair, twin, triple & double twin application

System Type Model Availability Product name PG 71 100 125 140

Air cooled

Heat pump

6.8 kW 9.5 kW 12.1 kW 13.4 kW

- Industry leading technology for commercial applications - Dedicated solution for infrastructure cooling - Variable Refrigerant Temperature - Maximum piping length up to 85m - Replacement technology - Extended operation range down to -20°C in both heating and cooling - Pair, twin, triple and double twin application

June ‘17

RZAG-MV1 15

RZAG-MY1 15

- Technology and comfort combined for commercial applications - Very compact and easy to install outdoor units - Maximum piping length up to 50m - Replacement technology - Operation range down to -15°C both cooling and in heating - Pair, twin, triple and double twin application

July ‘17

RZASG-MV1 16

RZASG-MY1 16

- Ideal solution for busy environments and small shops - Very compact and easy to install outdoor units - Maximum piping length up to 30m - Replacement technology - Easy-to-mount outdoor units: roof, terrace or wall - Exclusively offered for pair applications

July ‘17

AZAS-MV1 17

AZAS-MY1 17

Capacity clas

Page 13: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

13

Outdoor units

RZAG-MV1 / MY1 RZASG-MV1 / MY1 AZAS-MV1 / MY1

We

care

icon

s

Seasonal efficiency - Smart use of energy

Seasonal efficiency gives a more realistic indication on how efficient air conditioners operate over an entire heating or cooling season.

A++ A+ A

Inverter technology In combination with inverter controlled outdoor units Replacement technology

Service and maintenance with R-22 is prohibited after 1/01/2015, meaning repairs will be impossible to R-22 systems. Avoid unexpected downtime for your customers and replace these systems now!

Com

fort Night quiet Lowers the operation sound of the outdoor unit automatically.

Auto cooling-heating changeover

Automatically selects cooling or heating mode to achieve the set temperature.

Oth

er fu

nctio

ns

Variable refrigeration temperature

The intelligent systems ensures highest energy savings with additional comfort to better suit application requirements.

Twin/triple/double twin application

2, 3 or 4 indoor units can be connected to only 1 outdoor unit even if they have different capacities. All indoor units operate within the same mode (cooling or heating) from one remote control.

Swing compressor Outdoor units are fitted with a swing compressor, renowned for its low noise and high reliability

Guaranteed operation down to -20°C

Daikin is suitable for all climates, even withstanding severe winter conditions with an operation range down to -20°C.

Infrastructure coolingFor high sensible, infrastructure cooling applications, dedicated infrastructure cooling settings and allowing asymmetric combinations enhance the system’s reliability.

Technical benefitsCompact single fan casing Increased piping possibility 85 m 50 m 30 m

New frontplate design 7 segment display Increased factory charge Integrated leak check Refrigerant bottom plate pass Refrigerant HEX pass Swing compressor on R-32 Refrigerant cooled PCB’s Intelligent Tablet controller - Online controller app

Main benefit overview

Page 14: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

14

Page 15: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

15

Comfort cooling combination table

RZAG100-140MV1/MY1

Sky Air Alpha-series

Industry leading technology for commercial applications and technical rooms

ʯ Top efficiency: • energy labels up to A++ in both cooling and heating • compressor offers substantial improvements in efficiency

ʯ The perfect balance in efficiency and comfort due to Variable Refrigerant Temperature: top seasonal efficiency throughout most of the year and quick reaction speed on the hot days.

ʯ For high sensible infrastructure cooling applications ʯ Replace existing systems without having to replace the piping

ʯ Extended operation range down to -20°C in heating and cooling ʯ With a gas cooled PCB, reliable cooling is guaranteed, as it is not influenced by ambient temperature

ʯ Maximum piping length up to 85m

RZAG-MV1/MY1

More details and final information can be found our my.daikin.eu RZAG-MV1 RZAG-MY1

Infrastructure cooling combination table

FAA-

A

FHA

-A

FBA

-A

FDX

M-F

3

FUA

-A

FVA

-A

FFA

-A

FCA

HG

-G

FCA

G-A

capacity class 71 100 35 50 60 71 100 125 140 35 50 60 71 100 125 140 35 50 60 71 100 125 71 100 125 140 35 50 60 71 100 125 140 35 50 60 71 100 125 140

RZAG71MV1 RZAG71MY1 P 3 2 P 3 2 P 3 2 P P 3 2 P 3 2 PRZAG100MV1 RZAG100MY1 2 4 3 2 P 4 3 2 P 4 3 2 P 4 3 2 P 4 3 2 PRZAG125MV1 RZAG125MY1 2 4 3 2 P 4 3 2 P 4 3 2 P 4 3 2 P 4 3 2 PRZAG140MV1 RZAG140MY1 2 4 3 2 P 4 3 2 P 4 3 2 P 4 3 2 P 4 3 2 P

P = Pair, 2 = Twin, 3 = Triple, 4 = Double twin; For more information on infrastructure cooling options refer to infrastructure cooling catalogue.

FCAH

G-G

FCAG

-A

FFA

-A

FDA

-A

FDXM

-F3

FBA

-A

FHA

-A

FAA

-A

FUA

-A

FNA

-A

FVA

-A

capacity class 71 100 125 140 35 50 60 71 100 125 140 35 50 60 125 35 50 60 35 50 60 71 100 125 140 35 50 60 71 100 125 140 71 100 71 100 125 35 50 60 71 100 125 140

RZAG71MV1 RZAG71MY1 2 P 2 2 2 P 2 P P P 2 P 2RZAG100MV1 RZAG100MY1 P 3 2 P 3 2 3 2 3 2 P 3 2 P P P 3 2 PRZAG125MV1 RZAG125MY1 P 4 3 2 P 4 3 2 P 4 3 2 4 3 2 P 4 3 2 P P 4 3 2 PRZAG140MV1 RZAG140MY1 2 P 4 3 2 P 4 3 4 3 4 3 2 P 4 3 2 P 2 2 4 3 P

P = application ; 2/3/4 = twin/tripple/double twin application

Outdoor unit RZAG 71MV1 100MV1 125MV1 140MV1 71MY1 100MY1 125MY1 140MY1Dimensions Unit HeightxWidthxDepth mm 990x940x320 1,430x940x320 990x940x320 1,430x940x320Weight Unit kg 70 92 70 92Sound power level Cooling dBA 64 66 69 70 65 66 69 70Sound pressure level Cooling Nom. dBA 46 47 50 51 46 47 50 51

Heating Nom. dBA 49 51 52 49 51 52Operation range Cooling Ambient Min.~Max. °CDB -20~52

Heating Ambient Min.~Max. °CWB -20~18.0Refrigerant Type/GWP R-32/675

Charge kg/TCO2Eq 2.95/1.99 3.75/2.53 2.95/1.99 3.75/2.53Piping connections Liquid/Gas mm 9,52/15.9

Piping length

OU - IU Max. m 55 85 55 85System Equivalent m 75 100 75 100

Chargeless m 40Additional refrigerant charge kg/m See installation manualLevel difference IU - OU Max. m 30.0

Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3~/50/380-415Current - 50Hz Maximum fuse amps (MFA) A 20 32 16

Page 16: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

16

RZASG100-140MV1/MY1

Sky Air Advance-series

Technology and comfort combined for commercial applications

ʯ High efficiency: • Energy labels up to A++ (cooling) /A+ (heating)• compressor offers substantial efficiency improvements

ʯ Very compact and easy to install outdoor units ʯ Replace existing systems without having to replace the piping

ʯ Guarantees operation in both heating and cooling mode down to -15°C

ʯ With a gas cooled PCB, reliable cooling is guaranteed, as it is not influenced by ambient temperature

ʯ Maximum piping length up to 50m.

RZASG-MV1/MY1

More details and final information can be found our my.daikin.eu RZASG-MV1 RZASG-MY1

Pair, twin, triple and double twin application

FCAG-A FFA-A FDXM-F3 FBA-A

capacity class 35 50 60 71 100 125 140 35 50 60 35 50 60 35 50 60 71 100 125 140

RZASG71MV1 2 P 2 2 2 P

RZASG100MV1 RZASG100MY1 3 2 P 3 2 3 2 P

RZASG125MV1 RZASG125MY1 4 3 2 P 4 3 2 4 3 2 4 3 2 P

RZASG140MV1 RZASG140MY1 4 3 2 P 4 3 4 3 4 3 2 P

FDA-A FHA-A FUA-A FAA-A FVA-A FNA-A

capacity class 125 35 50 60 71 100 125 140 71 100 125 71 100 71 100 125 140 35 50 60

RZASG71MV1 2 P P P P 2 2

RZASG100MV1 RZASG100MY1 3 2 P P P P 3 2

RZASG125MV1 RZASG125MY1 P 4 3 2 P P P 4 3 2

RZASG140MV1 RZASG140MY1 4 3 2 P 2 2 P 4 3

Outdoor unit RZASG 71MV1 100MV1 125MV1 140MV1 100MY1 125MY1 140MY1Dimensions Unit HeightxWidthxDepth mm 770x900x320 990x940x320Weight Unit kg 60 70 78 70 77Sound power level Cooling dBA 65 70 71 73 70 71 73Sound pressure level Cooling Nom. dBA 46 53 54 53 54

Heating Nom. dBA 47 57Operation range Cooling Ambient Min.~Max. °CDB -15~46

Heating Ambient Min.~Max. °CWB -15~15.5Refrigerant Type/GWP R-32/675

Charge kg/TCO2Eq 2.45/1.65 2.60/1.76 2.90/1.96 2.60/1.76 2.90/1.96Piping connections Liquid/Gas mm 9,52/15.9

Piping length

OU - IU Max. m 50System Equivalent m 70

Chargeless m 30Additional refrigerant charge kg/m See installation manualLevel difference IU - OU Max. m 30.0

Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3~/50/380-415Current - 50Hz Maximum fuse amps (MFA) A 20 25 32 16

Page 17: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

17

AZAS71MV1/MY1

Sky Air Active-series

Ideal solution for small shops

ʯ High efficiency: • Energy labels up to A+ (cooling) /A (heating) • compressor offers substantial efficiency improvements

ʯ Very compact and easy to install outdoor units ʯ Replace existing systems without having to replace the piping

ʯ Guarantees operation in both heating mode down to -15°C and in cooling mode down to -5°C

ʯ With a gas cooled PCB, reliable cooling is guaranteed, as it is not influenced by ambient temperature

ʯ Maximum piping length up to 30m ʯ Exclusively offered in pair applications

AZAS-MV1/MY1

More details and final information can be found our my.daikin.eu

AZAS-MY1AZAS-MV1

Pair applicationFCAG-A FBA-A FAA-A

Capacity class 71 100 125 140 71 100 125 140 71 100 125 140

AZAS-MV1 P P P P P P P P P P

AZAS-MY1 P P P P P P P

Outdoor unit AZAS 71M2V1B 100M7V1B 125M7V1B 140M7V1B 100M7Y1B 125M7Y1B 140M7Y1BDimensions Unit HeightxWidthxDepth mm 770x900x320 990x940x320Weight Unit kg 60 70 78 70 77Sound power level Cooling dBA 65 70 71 73 70 71 73Sound pressure level Cooling Nom. dBA 46 53 54 53 54

Heating Nom. dBA 47 57Operation range Cooling Ambient Min.~Max. °CDB -5~46

Heating Ambient Min.~Max. °CWB -15~15.5Refrigerant Type/GWP R-32/675

Charge kg/TCO2Eq 2.45/1.65 2.60/1.76 2.90/1.96 2.60/1.76 2.90/1.96Piping connections Liquid/Gas mm 9,52/15.9

Piping length

OU - IU Max. m 30System Equivalent m 50

Chargeless m 30Additional refrigerant charge kg/m See installation manualLevel difference IU - OU Max. m 30.0

Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3~/50/380-415Current - 50Hz Maximum fuse amps (MFA) A 20 25 32 16

Page 18: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

18

TypeModel

Product name PG 25 35 50 60 71 100 125 140Sky Air Alpha-series

Sky Air Advance-

series

Sky Air Active-series

Ceiling mounted cassette

UNIQUEHigh COP, round flow cassette

FCAHG-G 25

360° air discharge for the highest efficiency and comfort - High COP cassette ensures top performance for commercial applications - Auto cleaning function ensures high efficiency - Intelligent sensors save energy and maximize comfort - Flexibility to suit every room layout

UNIQUERound flow cassette

FCAG-A 26-29

360° air discharge for the highest efficiency and comfort - Auto cleaning function ensures high efficiency - Intelligent sensors save energy and maximize comfort - Flexibility to suit every room layout - Lowest installation height in the market - 27~29 dB(A) on low fan speed

UNIQUEFully flat cassette FFA-A 33

Unique design in the market that integrates fully flat into the ceiling - Perfect integration in standard architectural ceiling tiles - Blend of iconic design and engineering excellence with a white or silver and white

finish - Intelligent sensors save energy and maximize comfort - Flexibility to suit every room layout without changing the location of the unit! - Quietest 600 x 600 cassette on the market

Concealed ceiling

Slim concealed ceiling unit FDXM-F3 36

Slim design for flexible installation - Compact dimensions enable installation in narrow ceiling voids

- Medium external static pressure up to 40Pa - Small capacity unit developed for small of well insulated rooms - Auto cleaning function ensures high efficiency and reliability

Concealed ceiling unit with medium ESP FBA-A 37-40

Slimmest yet most powerfull medium static pressure unit on the market! - Slimmest unit in class, only 245mm - Low operating sound level - Medium external static pressure up to 150Pa facilitates using flexible ducts of varying

lengths - Automatic air flow adjustment function measures the air volume and static pressure

and adjusts it towards the nominal air flow, guaranteeing comfort

Concealed ceiling unit with high ESP FDA-A 41

ESP up to 200Pa, ideal for large sized buildings - Discretely concealed in the ceiling: only the grilles are visible - Possibility to change ESP via wired remote control allows optimisation of the supply

air volume - Flexible installation as the air suction direction can be altered from rear to bottom

suction

Wall mounted Wall mounted unit FAA-A 42-44

For rooms with no false ceilings nor free floor space - The air is comfortably spread up- and downwards thanks to 5 different discharge

angles - Easy maintenance as this can be done from the front of the unit - Easy to install: 100 class is 35% lighter than previous model - Flexible to install: pipe connection can be bottom, left or right

Ceiling suspended

Ceiling suspended unit FHA-A 45-47

For wide rooms with no false ceilings nor free floor space - Ideal for comfortable air flow in wide rooms thanks to Coanda effect - Even rooms with ceilings up to 3.8m can be heated up or cooled down very easily! - Can be mounted in corners or narrow spaces without any problem

UNIQUE4-way blow ceiling suspended unit

FUA-A 48-49

Unique Daikin unit for high rooms with no false ceilings nor free floor space - Even rooms with ceilings up to 3.5m can be heated up or cooled down very easily! - Flexibility to suit every room layout without changing the location of the unit! - Optimum comfort guaranteed with automatic air flow adjustment to the required

load - The air is comfortably spread up- and downwards thanks to 5 different discharge

angles

Floor standing

Floor standing unit FVA-A 50-51

For spaces with high ceilings - Ideal solution for commercial spaces with no or narrow false ceilings - Even rooms with very high ceilings can be heated up or cooled down very easily! - Guarantees a stable temperature - Vertical and horizontal outblow

Concealed floor standing unit FNA-A 53

Designed to be concealed in walls, only grilles remain visible - Slimmest unit on the market with a depth of only 200mm! - Both window sill or ducted installation are possible thanks to sufficient ESP - Whisper quiet operation allows installation in any location

1) Twin, triple, double twin application is only possible up to 125 class

Product overviewIndoor units

Page 19: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

19

TypeModel

Product name PG 25 35 50 60 71 100 125 140Sky Air Alpha-series

Sky Air Advance-

series

Sky Air Active-series

Ceiling mounted cassette

UNIQUEHigh COP, round flow cassette

FCAHG-G 25

360° air discharge for the highest efficiency and comfort - High COP cassette ensures top performance for commercial applications - Auto cleaning function ensures high efficiency - Intelligent sensors save energy and maximize comfort - Flexibility to suit every room layout

UNIQUERound flow cassette

FCAG-A 26-29

360° air discharge for the highest efficiency and comfort - Auto cleaning function ensures high efficiency - Intelligent sensors save energy and maximize comfort - Flexibility to suit every room layout - Lowest installation height in the market - 27~29 dB(A) on low fan speed

UNIQUEFully flat cassette FFA-A 33

Unique design in the market that integrates fully flat into the ceiling - Perfect integration in standard architectural ceiling tiles - Blend of iconic design and engineering excellence with a white or silver and white

finish - Intelligent sensors save energy and maximize comfort - Flexibility to suit every room layout without changing the location of the unit! - Quietest 600 x 600 cassette on the market

Concealed ceiling

Slim concealed ceiling unit FDXM-F3 36

Slim design for flexible installation - Compact dimensions enable installation in narrow ceiling voids

- Medium external static pressure up to 40Pa - Small capacity unit developed for small of well insulated rooms - Auto cleaning function ensures high efficiency and reliability

Concealed ceiling unit with medium ESP FBA-A 37-40

Slimmest yet most powerfull medium static pressure unit on the market! - Slimmest unit in class, only 245mm - Low operating sound level - Medium external static pressure up to 150Pa facilitates using flexible ducts of varying

lengths - Automatic air flow adjustment function measures the air volume and static pressure

and adjusts it towards the nominal air flow, guaranteeing comfort

Concealed ceiling unit with high ESP FDA-A 41

ESP up to 200Pa, ideal for large sized buildings - Discretely concealed in the ceiling: only the grilles are visible - Possibility to change ESP via wired remote control allows optimisation of the supply

air volume - Flexible installation as the air suction direction can be altered from rear to bottom

suction

Wall mounted Wall mounted unit FAA-A 42-44

For rooms with no false ceilings nor free floor space - The air is comfortably spread up- and downwards thanks to 5 different discharge

angles - Easy maintenance as this can be done from the front of the unit - Easy to install: 100 class is 35% lighter than previous model - Flexible to install: pipe connection can be bottom, left or right

Ceiling suspended

Ceiling suspended unit FHA-A 45-47

For wide rooms with no false ceilings nor free floor space - Ideal for comfortable air flow in wide rooms thanks to Coanda effect - Even rooms with ceilings up to 3.8m can be heated up or cooled down very easily! - Can be mounted in corners or narrow spaces without any problem

UNIQUE4-way blow ceiling suspended unit

FUA-A 48-49

Unique Daikin unit for high rooms with no false ceilings nor free floor space - Even rooms with ceilings up to 3.5m can be heated up or cooled down very easily! - Flexibility to suit every room layout without changing the location of the unit! - Optimum comfort guaranteed with automatic air flow adjustment to the required

load - The air is comfortably spread up- and downwards thanks to 5 different discharge

angles

Floor standing

Floor standing unit FVA-A 50-51

For spaces with high ceilings - Ideal solution for commercial spaces with no or narrow false ceilings - Even rooms with very high ceilings can be heated up or cooled down very easily! - Guarantees a stable temperature - Vertical and horizontal outblow

Concealed floor standing unit FNA-A 53

Designed to be concealed in walls, only grilles remain visible - Slimmest unit on the market with a depth of only 200mm! - Both window sill or ducted installation are possible thanks to sufficient ESP - Whisper quiet operation allows installation in any location

Capacity class

Indoor units Full R-32

line up

NEW auto

cleaning option

NEW Multi

zoning option

NEW Multi

zoning option

Page 20: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

20

Ceiling mountedcassette

units

Concealed ceiling units

Ceiling suspended

units

4-Way blow ceiling

suspended unit

Wall mounted

unit

Floor standing

units

FCAHG-G FCAG-A FFA-A FDXM-F3 FBA-A FDA-A FHA-A FUA-A FAA-A FVA-A FNA-A

We

care

Seasonal efficiency - Smart use of energy

Seasonal efficiency gives a more realistic indication on how efficient air conditioners operate over an entire heating or cooling season. • • • • • • • • • •

Inverter technology In combination with inverter controlled outdoor units • • • • • • • • • •Home leave operation During absence, the indoor temperature can be maintained at a certain level. • • • • • • • • • •Fan only The air conditioner can be used as fan, blowing air without cooling or heating. • • • • • • • • • • •Auto cleaning filter The filter automatically cleans itself. Simplicity of upkeep means optimum energy efficiency and maximum comfort

without the need for expensive or time-consuming maintenance. • • Floor and presence sensor

The presence sensor directs the air away from any person detected in the room, when the air flow control is on. The floor sensor detects the average floor temperature and ensures an even temperature distribution between ceiling and floor.

• • •

Com

fort

Draught prevention When starting to warm up or when the thermostat is off, the air discharge direction is set horizontally and the fan to low speed, to prevent draught. After warming up, air discharge and fan speed are set as desired. • • • •

Whisper quiet Daikin indoor units are whisper quiet. Also the outdoor units are guaranteed not to disturb the quiet of the neightbourhood. • • • •

Auto cooling-heating changeover Automatically selects cooling or heating mode to achieve the set temperature. • • • • • • • • • •

Air t

reat

men

t

Air filter Removes airborne dust particles to ensure a steady supply of clean air. • • • • • • • • • • •

Hum

idity

co

ntro

l

Dry programme Allows humidity levels to be reduced without variations in room temperature. • • • • • • • • • • •

Air

flow

Ceiling soiling prevention A special function prevents air blowing out too long in horizontal position, to prevent ceiling stains. • • •Vertical auto swing Possibility to select automatic vertical moving of the air discharge louvre, for uniform air flow and temperature

distribution. • • • • • • •Fan speed steps Allows to select up to the given number of fan speed. 5 5 3 3 3 3 3 5 3 3 2

Individual flap control

Individual flap control via the wired remote controller makes it simple to fix the position of each flap individually, to suit any new room configuration. Optional closure kits are available as well. • • • •

Rem

ote

cont

rol &

tim

er Weekly timer Timer can be set to start operation anytime on a daily or weekly basis • • • • depending on controller

• • • • • • •Infrared remote control Infrared remote control with LCD to start, stop and regulate the air conditioner from a distance. optional optional optional optional optional optional optional optional optional optional

Wired remote control Wired remote control to start, stop and regulate the air conditioner from a distance. optional optional optional optional optional optional optional optional optional optional optional

Centralised control Centralised control to start, stop and regulate several air conditioners from one central point. optional optional optional optional optional optional optional optional optional optional optional

Multi zoning NEW Allows up to 6 individual climate zones with one indoor unit

Oth

er fu

nctio

ns

Infrastructure cooling

Remove in a reliable, efficient and flexible way the heat constantly generated by the IT and server equipment to ensure maximum uptime while offering the best return on investment. • • • • • • • •

Auto-restart The unit restarts automatically at the original settings after power failure. • • • • • • • • • • •Self-diagnosis Simplifies maintenance by indicating system faults or operating anomalies. • • • • • • • • • • •Drain pump kit Facilitates condensation draining from the indoor unit. standard standard standard standard standard optional standard optional

Twin/triple/double twin application

2, 3 or 4 indoor units can be connected to only 1 outdoor unit. All indoor units operate within the same mode (cooling or heating) from one remote control. • • • • • • • • •

Multi model application

Up to 5 indoor units (even different capacities) can be connected to a single outdoor unit. All indoor units can individually be operated within the same mode. • • • • • •

Indoor units

Benefits overview

Page 21: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

21

Ceiling mountedcassette

units

Concealed ceiling units

Ceiling suspended

units

4-Way blow ceiling

suspended unit

Wall mounted

unit

Floor standing

units

FCAHG-G FCAG-A FFA-A FDXM-F3 FBA-A FDA-A FHA-A FUA-A FAA-A FVA-A FNA-A

We

care

Seasonal efficiency - Smart use of energy

Seasonal efficiency gives a more realistic indication on how efficient air conditioners operate over an entire heating or cooling season. • • • • • • • • • •

Inverter technology In combination with inverter controlled outdoor units • • • • • • • • • •Home leave operation During absence, the indoor temperature can be maintained at a certain level. • • • • • • • • • •Fan only The air conditioner can be used as fan, blowing air without cooling or heating. • • • • • • • • • • •Auto cleaning filter The filter automatically cleans itself. Simplicity of upkeep means optimum energy efficiency and maximum comfort

without the need for expensive or time-consuming maintenance. • • Floor and presence sensor

The presence sensor directs the air away from any person detected in the room, when the air flow control is on. The floor sensor detects the average floor temperature and ensures an even temperature distribution between ceiling and floor.

• • •

Com

fort

Draught prevention When starting to warm up or when the thermostat is off, the air discharge direction is set horizontally and the fan to low speed, to prevent draught. After warming up, air discharge and fan speed are set as desired. • • • •

Whisper quiet Daikin indoor units are whisper quiet. Also the outdoor units are guaranteed not to disturb the quiet of the neightbourhood. • • • •

Auto cooling-heating changeover Automatically selects cooling or heating mode to achieve the set temperature. • • • • • • • • • •

Air t

reat

men

t

Air filter Removes airborne dust particles to ensure a steady supply of clean air. • • • • • • • • • • •

Hum

idity

co

ntro

l

Dry programme Allows humidity levels to be reduced without variations in room temperature. • • • • • • • • • • •

Air

flow

Ceiling soiling prevention A special function prevents air blowing out too long in horizontal position, to prevent ceiling stains. • • •Vertical auto swing Possibility to select automatic vertical moving of the air discharge louvre, for uniform air flow and temperature

distribution. • • • • • • •Fan speed steps Allows to select up to the given number of fan speed. 5 5 3 3 3 3 3 5 3 3 2

Individual flap control

Individual flap control via the wired remote controller makes it simple to fix the position of each flap individually, to suit any new room configuration. Optional closure kits are available as well. • • • •

Rem

ote

cont

rol &

tim

er Weekly timer Timer can be set to start operation anytime on a daily or weekly basis • • • • depending on controller

• • • • • • •Infrared remote control Infrared remote control with LCD to start, stop and regulate the air conditioner from a distance. optional optional optional optional optional optional optional optional optional optional

Wired remote control Wired remote control to start, stop and regulate the air conditioner from a distance. optional optional optional optional optional optional optional optional optional optional optional

Centralised control Centralised control to start, stop and regulate several air conditioners from one central point. optional optional optional optional optional optional optional optional optional optional optional

Multi zoning NEW Allows up to 6 individual climate zones with one indoor unit

Oth

er fu

nctio

ns

Infrastructure cooling

Remove in a reliable, efficient and flexible way the heat constantly generated by the IT and server equipment to ensure maximum uptime while offering the best return on investment. • • • • • • • •

Auto-restart The unit restarts automatically at the original settings after power failure. • • • • • • • • • • •Self-diagnosis Simplifies maintenance by indicating system faults or operating anomalies. • • • • • • • • • • •Drain pump kit Facilitates condensation draining from the indoor unit. standard standard standard standard standard optional standard optional

Twin/triple/double twin application

2, 3 or 4 indoor units can be connected to only 1 outdoor unit. All indoor units operate within the same mode (cooling or heating) from one remote control. • • • • • • • • •

Multi model application

Up to 5 indoor units (even different capacities) can be connected to a single outdoor unit. All indoor units can individually be operated within the same mode. • • • • • •

Indoor units

NEW

NEW

NEW

Page 22: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

22

Why choose a round flow cassette?• 360° air discharge for optimum comfort

• Intelligent sensors for maximum efficiency

ARGUE CARDS

More energy efficient and user-friendly than any other cassette › Running costs are reduced by 50% compared with standard solutions

› Automatic filter cleaning. › Less time is required to maintain the filter: dust can be removed easily with a vacuum cleaner without opening the unit.

Finer mesh panel › For dust prone areas (i.e. clothing and book shops) a finer mesh panel (BYCQ140DGF9) ensures consistent performance and optimum air distribution

› Clean ceilings ensured thanks to fine mesh and clean filter

BYCQ140DG9 BYCQ140DGF9

Auto-cleaning panelAuto-cleaning panel with fine mesh filter

White with grey louvers White with grey louvers

Auto-cleaning cassette for maintaining the optimum store atmosphere Dust can be removed easily

with a vacuum cleaner without opening the unit.

Air distribution with a clean filter Air distribution with a dusty filter

FCAHG-G/FCAG-A

Auto cleaning cassette

Page 23: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

23

Energy consumption (kWh)

Auto cleaning cassette

Standard round flow cassette

Cumulative energy comparison over 12 months July Aug. Sept. Oct. Nov. Dec. Jan. Feb. March April May June July

9000

8000

7000

6000

5000

4000

3000

2000

1000

0

References Coral shop, UK Running costs were reduced by up to 50% compared with standard solutions thanks to clean filter

Up to 50% savings thanks to

automated cleaning

Marketing tools › Visit the website: https://www.daikin.eu/en_us/product-group/round-flow-cassette.html

Benefits for the installer › Product with unique functions in this market. › Less time needed for onsite maintenance. › Use the controller to individually open or close any of the four flaps to easily adapt to a changing room layout.

› Easy set-up of the sensor option to improve comfort and save energy.

Benefits for the consultant › Product with unique functions in this market. › Designed for use in all types and sizes of commercial offices and retail environments.

› Ideal product for improving BREEAM score/EPBD in combination with Sky Air or VRV IV heat pump units.

Benefits for the end user › Designed for use in all types and sizes of commercial offices and retail environments.

› Perfect environment conditions: no more draughts or cold feet.

› Save up to 50% on running costs with the auto-cleaning panel, which also facilitates maintenance.

› Your customers can save up to 27% on their energy bills thanks to the sensor option.

› Flexible use of space thanks to individual flap control.

www.youtube.com/DaikinEurope

360° air discharge for improved comfort › Industry-first and proven design.

Intelligent sensors improve efficiency and comfort even more › The presence sensor adjusts the set point if no one is detected in the room leading to up to 27% savings. It also automatically directs air flow away from any person to avoid draught.

› The infrared floor sensor detects the average floor temperature and ensures even temperature distribution between ceiling and floor to prevent cold feet.

Flexible installation › Flaps can be individually controlled or closed using the wired remote control, to suit room configuration. Optional closure kits are also available.

presence sensor

floor sensor

Page 24: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

24

Page 25: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

25

BRC1E53A-B-C, BRC7FA532FRZAG100-140MV1_MY1

FCAHG-G

Efficiency data FCAHG + RZAG 71G + 71MV1 100G + 100MV1 125G + 125MV1 140G + 140MV1 71G + 71MY1 100G + 100MY1 125G + 125MY1 140G + 140MY1Cooling capacity Nom. kW 6.80 9.50 12.1 13.4 6.80 9.50 12.1 13.4 Heating capacity Nom. kW 7.50 10.8 13.5 15.5 7.50 10.8 13.5 15.5 Seasonal efficiency (according to EN14825)

Cooling Energy efficiency class A++ - A++ -Pdesign kW 6.80 9.50 12.1 13.4 6.80 9.50 12.1 13.4SEER 7.72 7.35 8.02 7.93 7.72 7.35 8.02 7.93Annual energy consumption kWh 308 452 905 1,014 308 452 905 1,014

Heating (Average climate)

Energy efficiency class A++ - A++ -Pdesign kW 4.70 9.52 4.70 9.52SCOP/A 4.61 4.81 4.53 4.44 4.61 4.81 4.53 4.44Annual energy consumption kWh 1,427 2,771 2,942 3,002 1,427 2,771 2,942 3,002

Indoor unit FCAHG 71G 100G 125G 140G 71G 100G 125G 140GDimensions Unit HeightxWidthxDepth mm 288x840x840Weight Unit kg 25Air filter Type Resin netDecoration panel Model BYCQ140DGF9 - auto cleaning panel with fine mesh filter / BYCQ140DG9 - auto cleaning panel / BYCQ140DW

- full white / BYCQ140D - white with grey louversColour Pure White (RAL 9010)Dimensions HeightxWidthxDepth mm 130x950x950 / 130x950x950 / 50x950x950 / 50x950x950Weight kg 10.3 / 10.3 / 5.4 / 5.4

Fan Air flow rate Cooling Low/Medium/High m³/min 12.2/16.7/21.2 19.0/25.7/32.3 19.9/26.7/33.5 21.1/27.3/33.5 12.2/16.7/21.2 19.0/25.7/32.3 19.9/26.7/33.5 21.1/27.3/33.5Heating Low/Medium/High m³/min 12.2/16.7/21.2 19.0/25.7/32.3 19.9/26.7/33.5 21.1/27.3/33.5 12.2/16.7/21.2 19.0/25.7/32.3 19.9/26.7/33.5 21.1/27.3/33.5

Sound power level Cooling dBA 53 61 53 61Heating dBA 53 61 53 61

Sound pressure level Cooling Low/High dBA 29/36 33/44 35/45 37/45 29/36 33/44 35/45 37/45Heating Low/High dBA 29/36 33/44 35/45 37/45 29/36 33/44 35/45 37/45

Control systems Infrared remote control BRC7FA532FWired remote control BRC1D528 / BRC1E53A7 / BRC1E53B7 / BRC1E53C7

Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220

Outdoor unit RZAG 71MV1 100MV1 125MV1 140MV1 71MY1 100MY1 125MY1 140MY1Dimensions Unit HeightxWidthxDepth mm 990x940x320 1,430x940x320 990x940x320 1,430x940x320Weight Unit kg 70 92 70 92Sound power level Cooling dBA 64 66 69 70 65 66 69 70Sound pressure level Cooling Nom. dBA 46 47 50 51 46 47 50 51

Heating Nom. dBA 49 51 52 49 51 52Operation range Cooling Ambient Min.~Max. °CDB -20~52

Heating Ambient Min.~Max. °CWB -20~18.0Refrigerant Type/GWP R-32/675

Charge kg/TCO2Eq 2.95/1.99 3.75/2.53 2.95/1.99 3.75/2.53Piping connections Liquid/Gas mm 9,52/15.9

Piping length

OU - IU Max. m 55 85 55 85System Equivalent m 75 100 75 100

Chargeless m 40Additional refrigerant charge kg/m See installation manualLevel difference IU - OU Max. m 30.0

Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3~/50/380-415Current - 50Hz Maximum fuse amps (MFA) A 20 32 16

(1) BYCQ140D7W1: pure white standard panel with grey louvers; BYCQ140D7W1W: pure white standard panel with white louvers; BYCQ140D7GW1: pure white auto cleaning panel. (2) EER/COP according to Eurovent 2012, for use outside EU only (3) The BYCQ140D7W1W has white insulations. Be informed that formation of dirt on white insulation is visibly stronger and that it is consequently not advised to install the BYCQ140D7W1W decoration panel in environ-ments exposed to concentrations of dirt. (4) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

High COP, round flow cassette

360° air discharge for optimum efficiency and comfort

ʯ High COP cassette ensures top performance, great savings in energy consumption and a comfortable environment for commercial applications

ʯ Unified indoor unit range for R-32 and R-410A ʯ Combining with R-32 Bluevolution technology, reduces environmental impact with 68% compared to R-410A, leads directly to lower energy consumption thanks to its high energy efficiency and has up to lower 16% refrigerant charge

ʯ Automatic filter cleaning results in higher efficiency & comfort and lower maintenance costs. 2 filters available: standard filter and finer mesh filter (for fine dust applications e.g. clothing shops)

ʯ Two optional intelligent sensors improve energy efficiency and comfort. ʯ Individual flap control: flexibility to suit every room layout without changing the location of the unit!

ʯ Modern style decoration panel is available in 3 different variations: white (RAL9010) with grey louvers, full white (RAL9010) or auto cleaning panel

ʯ 5 different fan speeds available for maximum comfort ʯ Reduced energy consumption thanks to specially developed small tube heat exchanger, DC fan motor and drain pump

ʯ Optional fresh air intake ʯ Branch duct discharge allows to optimize air distribution in irregular shaped rooms or to supply air to small adjacent rooms

FCAHG-G + RZAG-MV1/RZAG-MY1

NEW Online controller

connection

ʯ Standard drain pump with 675mm lift increases flexibility and installation speed

Page 26: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

26

BRC1E53A-B-C, BRC7FA532FRZAG100-140MV1_MY1

FCAG35-71A

Efficiency data FCAG + RZAG 71A + 71MV1 100A + 100MV1 125A + 125MV1 140A + 140MV1 71A + 71MY1 100A + 100MY1 125A + 125MY1 140A + 140MY1Cooling capacity Nom. kW 6.80 9.50 12.1 13.4 6.80 9.50 12.1 13.4 Heating capacity Nom. kW 7.50 10.8 13.5 15.5 7.50 10.8 13.5 15.5 Seasonal efficiency (according to EN14825)

Cooling Energy efficiency class A++ - A++ -Pdesign kW 6.80 9.50 12.1 13.4 6.80 9.50 12.1 13.4SEER 6.86 7.14 7.80 7.17 6.86 7.14 7.80 7.17Annual energy consumption kWh 347 466 931 1,121 347 466 931 1,121

Heating (Average climate)

Energy efficiency class A+ A++ - A+ A++ -Pdesign kW 4.70 7.80 9.52 4.70 7.80 9.52SCOP/A 4.41 4.61 4.34 4.41 4.61 4.34Annual energy consumption kWh 1,492 2,369 3,071 1,492 2,369 3,071

Indoor unit FCAG 71A 100A 125A 140A 71A 100A 125A 140ADimensions Unit HeightxWidthxDepth mm 204x840x840 246x840x840 204x840x840 246x840x840Weight Unit kg 21 24 21 24Air filter Type Resin netDecoration panel Model BYCQ140DGF9 - auto cleaning panel with fine mesh filter / BYCQ140DG9 - auto cleaning panel / BYCQ140DW

- full white / BYCQ140D - white with grey louversColour Pure White (RAL 9010)Dimensions HeightxWidthxDepth mm 130x950x950 / 130x950x950 / 50x950x950 / 50x950x950Weight kg 10.3 / 10.3 / 5.4 / 5.4

Fan Air flow rate Cooling Low/Medium/High m³/min 9.3/12.5/15.3 12.4/17.6/22.8 12.4/19.2/26.0 9.3/12.5/15.3 12.4/17.6/22.8 12.4/19.2/26.0Heating Low/Medium/High m³/min 9.1/12.1/15.0 12.4/17.6/22.8 12.4/19.2/26.0 9.1/12.1/15.0 12.4/17.6)/22.8 12.4/19.2/26.0

Sound power level Cooling dBA 51 54 58 51 54 58Heating dBA 51 54 58 51 54 58

Sound pressure level Cooling Low/High dBA 28/35 29/37 29/41 28/35 29/37 29/41Heating Low/High dBA 28/33 29/37 29/41 28/33 29/37 29/41

Control systems Infrared remote control BRC7FA532FWired remote control BRC1D528 / BRC1E53A7 / BRC1E53B7 / BRC1E53C7

Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220

Outdoor unit RZAG 71MV1 100MV1 125MV1 140MV1 71MY1 100MY1 125MY1 140MY1Dimensions Unit HeightxWidthxDepth mm 990x940x320 1,430x940x320 990x940x320 1,430x940x320Weight Unit kg 70 92 78 70 92Sound power level Cooling dBA 64 66 69 73 65 66 69 70Sound pressure level Cooling Nom. dBA 46 47 50 54 46 47 50 51

Heating Nom. dBA 49 51 52 57 49 51 52Operation range Cooling Ambient Min.~Max. °CDB -20~52 -15~46 -20~52

Heating Ambient Min.~Max. °CWB -20~18.0 -15~15.5 -20~18.0Refrigerant Type/GWP R-32/675

Charge kg/TCO2Eq 2.95/1.99 3.75/2.53 2.90/1.96 2.95/1.99 3.75/2.53Piping connections Liquid/Gas mm 9,52/15.9

Piping length

OU - IU Max. m 55 85 50 55 85System Equivalent m 75 100 70 75 100

Chargeless m 40 30 40Additional refrigerant charge kg/m See installation manualLevel difference IU - OU Max. m 30.0

Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3~/50/380-415Current - 50Hz Maximum fuse amps (MFA) A 20 32 16 (1) BYCQ140D7W1: pure white standard panel with grey louvers; BYCQ140D7W1W: pure white standard panel with white louvers; BYCQ140D7GW1: pure white auto cleaning panel. (2) EER/COP according to Eurovent 2012, for use outside EU only (3) The BYCQ140D7W1W has white insulations. Be informed that formation of dirt on white insulation is visibly stronger and that it is consequently not advised to install the BYCQ140D7W1W decoration panel in environ-ments exposed to concentrations of dirt. (4) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

Round flow cassette

360° air discharge for optimum efficiency and comfort

ʯ Combination with Sky Air Alpha-series ensures best in class quality, highest efficiency and performance

ʯ Unified indoor unit range for R-32 and R-410A ʯ Combining with R-32 Bluevolution technology, reduces environmental impact with 68% compared to R-410A, leads directly to lower energy consumption thanks to its high energy efficiency and has up to lower 16% refrigerant charge

ʯ Automatic filter cleaning results in higher efficiency & comfort and lower maintenance costs. 2 filters available: standard filter and finer mesh filter (for fine dust applications e.g. clothing shops)

ʯ Two optional intelligent sensors improve energy efficiency and comfort. ʯ Individual flap control: flexibility to suit every room layout without changing the location of the unit!

ʯ Lowest installation height in the market: 214mm for class 20-63 ʯ Modern style decoration panel is available in 3 different variations: white (RAL9010) with grey louvers, full white (RAL9010) or auto cleaning panel

ʯ 5 different fan speeds available for maximum comfort ʯ Reduced energy consumption thanks to specially developed small tube heat exchanger, DC fan motor and drain pump

ʯ Optional fresh air intake ʯ Branch duct discharge allows to optimize air distribution in irregular shaped rooms or to supply air to small adjacent rooms

ʯ Standard drain pump with 675mm lift increases flexibility and installation speed

FCAG-A + RZAG-MV1/RZAG-MY1

NEW Online controller connection

Page 27: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

27

BRC1E53A-B-C, BRC7FA532FRZASG100-140MV1_MY1

FCAG35-71A

Efficiency data FCAG + RZASG 71A + 71MV1 100A + 100MV1 125A + 125MV1 140A + 140MV1 100A + 100MY1 125A + 125MY1 140A + 140MY1Cooling capacity Nom. kW 6.80 9.50 12.1 13.4 9.50 12.1 13.4 Heating capacity Nom. kW 7.50 10.8 13.5 15.5 10.8 13.5 15.5 Seasonal efficiency (according to EN14825)

Cooling Energy efficiency class A++ - A++ -Pdesign kW 6.80 9.50 12.1 13.4 9.50 12.1 13.4SEER 6.47 6.55 5.76 6.53 6.55 5.76 6.53Annual energy consumption kWh 368 507 1,261 1,231 507 1,261 1,231

Heating (Average climate)

Energy efficiency class A A+ - A+ -Pdesign kW 4.50 6.00 7.80 6.00 7.80SCOP/A 4.00 4.17 4.05 4.31 4.17 4.05 4.31Annual energy consumption kWh 1,575 2,016 2,074 2,534 2,016 2,074 2,534

Indoor unit FCAG 71A 100A 125A 140A 100A 125A 140ADimensions Unit HeightxWidthxDepth mm 204x840x840 246x840x840Weight Unit kg 21 24Air filter Type Resin netDecoration panel Model BYCQ140DGF9 - auto cleaning panel with fine mesh filter / BYCQ140DG9 - auto cleaning panel / BYCQ140DW - full

white / BYCQ140D - white with grey louversColour Pure White (RAL 9010)Dimensions HeightxWidthxDepth mm 130x950x950 / 130x950x950 / 50x950x950 / 50x950x950Weight kg 10.3 / 10.3 / 5.4 / 5.4

Fan Air flow rate Cooling Low/Medium/High m³/min 9.3/12.5/15.3 12.4/17.6/22.8 12.4/19.2/26.0 12.4/17.6/22.8 12.4/19.2/26.0Heating Low/Medium/High m³/min 9.1/12.1/15.0 12.4/17.6/22.8 12.4/19.2/26.0 12.4/17.6/22.8 12.4/19.2/26.0

Sound power level Cooling dBA 51 54 58 54 58Heating dBA 51 54 58 54 58

Sound pressure level Cooling Low/High dBA 28/35 29/37 29/41 29/37 29/41Heating Low/High dBA 28/33 29/37 29/41 29/37 29/41

Control systems Infrared remote control BRC7FA532FWired remote control BRC1D528 / BRC1E53A7 / BRC1E53B7 / BRC1E53C7

Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220

Outdoor unit RZASG 71MV1 100MV1 125MV1 140MV1 100MY1 125MY1 140MY1Dimensions Unit HeightxWidthxDepth mm 770x900x320 990x940x320Weight Unit kg 60 70 78 70 77Sound power level Cooling dBA 65 70 71 73 70 71 73Sound pressure level Cooling Nom. dBA 46 53 54 53 54

Heating Nom. dBA 47 57Operation range Cooling Ambient Min.~Max. °CDB -15~46

Heating Ambient Min.~Max. °CWB -15~15.5Refrigerant Type/GWP R-32/675

Charge kg/TCO2Eq 2.45/1.65 2.60/1.76 2.90/1.96 2.60/1.76 2.90/1.96Piping connections Liquid/Gas mm 9,52/15.9

Piping length

OU - IU Max. m 50System Equivalent m 70

Chargeless m 30Additional refrigerant charge kg/m See installation manualLevel difference IU - OU Max. m 30.0

Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3~/50/380-415Current - 50Hz Maximum fuse amps (MFA) A 20 25 32 16

Round flow cassette

360° air discharge for optimum efficiency and comfort

ʯ Combination with Sky Air Advance-series ensures good value for money for all types of commercial applications

ʯ Unified indoor unit range for R-32 and R-410A ʯ Combining with R-32 Bluevolution technology, reduces environmental impact with 68% compared to R-410A, leads directly to lower energy consumption thanks to its high energy efficiency and has up to lower 16% refrigerant charge

ʯ Automatic filter cleaning results in higher efficiency & comfort and lower maintenance costs. 2 filters available: standard filter and finer mesh filter (for fine dust applications e.g. clothing shops)

ʯ Two optional intelligent sensors improve energy efficiency and comfort.

ʯ Individual flap control: flexibility to suit every room layout without changing the location of the unit!

ʯ Lowest installation height in the market: 214mm for class 20-63 ʯ Modern style decoration panel is available in 3 different variations: white (RAL9010) with grey louvers, full white (RAL9010) or auto cleaning panel

FCAG-A + RZASG-MV1/RZASG-MY1

(1) BYCQ140D7W1: pure white standard panel with grey louvers; BYCQ140D7W1W: pure white standard panel with white louvers; BYCQ140D7GW1: pure white auto cleaning panel. (2) EER/COP according to Eurovent 2012, for use outside EU only (3) The BYCQ140D7W1W has white insulations. Be informed that formation of dirt on white insulation is visibly stronger and that it is consequently not advised to install the BYCQ140D7W1W decoration panel in environ-ments exposed to concentrations of dirt. (4) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

NEW Online controller connection

Page 28: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

28

Efficiency data FCAG + AZAS 71A + 71M2V1B 100A + 100M7V1B 125A + 125M7V1B 140A + 140M7V1B 100A + 100M7Y1B 125A + 125M7Y1B 140A + 140M7Y1BCooling capacity Nom. kW 6.80 9.50 12.1 13.4 9.50 12.1 13.4 Heating capacity Nom. kW 7.50 10.8 13.5 15.5 10.8 13.5 15.5 Seasonal efficiency (according to EN14825)

Cooling Energy efficiency class A+ - A+ -Pdesign kW 6.80 9.50 12.1 13.0 9.50 12.1 13.0SEER 5.87 5.67 5.40 6.00 5.67 5.40 6.00Annual energy consumption kWh 405 586 1,345 1,300 586 1,345 1,300

Heating (Average climate)

Energy efficiency class A - A -Pdesign kW 4.50 6.00 7.80 6.00 7.80SCOP/A 4.00 3.85 3.80 4.31 3.85 3.80 4.31Annual energy consumption kWh 1,575 2,182 2,211 2,534 2,182 2,211 2,534

Indoor unit FCAG 71A 100A 125A 140A 100A 125A 140ADimensions Unit HeightxWidthxDepth mm 204x840x840 246x840x840Weight Unit kg 21 24Air filter Type Resin netDecoration panel Model BYCQ140DGF9 - auto cleaning panel with fine mesh filter / BYCQ140DG9 - auto cleaning panel / BYCQ140DW - full

white / BYCQ140D - white with grey louversColour Pure White (RAL 9010)Dimensions HeightxWidthxDepth mm 130x950x950 / 130x950x950 / 50x950x950 / 50x950x950Weight kg 10.3/5.4/10.3/5.4

Fan Air flow rate Cooling Low/Medium/High m³/min 9.3/12.5/15.3 12.4/17.6/22.8 12.4/19.2/26.0 12.4/17.6/22.8 12.4/19.2 (0.000)/26.0Heating Low/Medium/High m³/min 9.1/12.1/15.0 12.4/17.6/22.8 12.4/19.2/26.0 12.4/17.6/22.8 12.4/19.2 (0.000)/26.0

Sound power level Cooling dBA 51 54 58 54 58Heating dBA 51 54 58 54 58

Sound pressure level Cooling Low/High dBA 28/35 29/37 29/41 29/37 29/41Heating Low/High dBA 28/33 29/37 29/41 29/37 29/41

Control systems Infrared remote control BRC7FA532FWired remote control BRC1D528 / BRC1E53A7 / BRC1E53B7 / BRC1E53C7

Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220

Outdoor unit AZAS 71M2V1B 100M7V1B 125M7V1B 140M7V1B 100M7Y1B 125M7Y1B 140M7Y1BDimensions Unit HeightxWidthxDepth mm 770x900x320 990x940x320Weight Unit kg 60 70 78 70 77Sound power level Cooling dBA 65 70 71 73 70 71 73Sound pressure level Cooling Nom. dBA 46 53 54 53 54

Heating Nom. dBA 47 57Operation range Cooling Ambient Min.~Max. °CDB -5~46

Heating Ambient Min.~Max. °CWB -15~15.5Refrigerant Type/GWP R-32/675

Charge kg/TCO2Eq 2.45/1.65 2.60/1.76 2.90/1.96 2.60/1.76 2.90/1.96Piping connections Liquid/Gas mm 9,52/15.9

Piping length

OU - IU Max. m 30System Equivalent m 50

Chargeless m 30Additional refrigerant charge kg/m See installation manualLevel difference IU - OU Max. m 30.0

Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3~/50/380-415Current - 50Hz Maximum fuse amps (MFA) A 20 25 32 16

BRC1E53A-B-C, BRC7FA532FAZAS71MV1_MY1

FCAG35-71A

Round flow cassette

360° air discharge for optimum efficiency and comfort

ʯ Ideal solution for small businesses and shops ʯ Unified indoor unit range for R-32 and R-410A ʯ Combining with R-32 Bluevolution technology, reduces environmental impact with 68% compared to R-410A, leads directly to lower energy consumption thanks to its high energy efficiency and has up to lower 16% refrigerant charge

ʯ Automatic filter cleaning results in higher efficiency & comfort and lower maintenance costs. 2 filters available: standard filter and finer mesh filter (for fine dust applications e.g. clothing shops)

ʯ Two optional intelligent sensors improve energy efficiency and comfort.

ʯ Individual flap control: flexibility to suit every room layout without changing the location of the unit!

ʯ Lowest installation height in the market: 214mm for class 20-63 ʯ Modern style decoration panel is available in 3 different variations: white (RAL9010) with grey louvers, full white (RAL9010) or auto cleaning panel

FCAG-A + AZAS-MV1/AZAS-MY1

(1) BYCQ140D7W1: pure white standard panel with grey louvers; BYCQ140D7W1W: pure white standard panel with white louvers; BYCQ140D7GW1: pure white auto cleaning panel. (2) EER/COP according to Eurovent 2012, for use outside EU only (3) The BYCQ140D7W1W has white insulations. Be informed that formation of dirt on white insulation is visibly stronger and that it is consequently not advised to install the BYCQ140D7W1W decoration panel in environ-ments exposed to concentrations of dirt. (4) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

NEW Online controller connection

Page 29: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

29

BRC1E53A-B-C_BRC7FA532FRXM20-35M9

FCAG35-71A

Efficiency data FCAG + RXM 35A + 35M9 50A + 50M9 60A + 60M9Cooling capacity Nom. kW 3.50 5.00 5.70Heating capacity Nom. kW 4.20 6.00 7.00Power input Cooling Nom. kW 0.94 1.39 1.72

Heating Nom. kW 1.11 1.62 2.07Seasonal efficiency (according to EN14825)

Cooling Energy efficiency class A++Pdesign kW 3.50 5.00 5.70SEER 6.35 6.54 6.40Annual energy consumption kWh 193 266 312

Heating (Average climate)

Energy efficiency class A++ A+Pdesign kW 3.32 4.36 4.71SCOP/A 4.90 4.30 4.20Annual energy consumption kWh 948 1,419 1,569

Indoor unit FCAG 35A 50A 60ADimensions Unit HeightxWidthxDepth mm 204x840x840Weight Unit kg 18 19Air filter Type Resin netDecoration panel Model BYCQ140DGF9 - auto cleaning panel with fine mesh filter / BYCQ140DG9 - auto cleaning panel / BYCQ140DW

- full white / BYCQ140D - white with grey louversColour Pure White (RAL 9010)Dimensions HeightxWidthxDepth mm 130x950x950 / 130x950x950 / 50x950x950 / 50x950x950Weight kg 10.3 / 10.3 / 5.4 / 5.4

Fan Air flow rate Cooling Low/Medium/High m³/min 8.7/10.6/12.5 8.7/10.7/12.6 8.7/11.2/13.6Heating Low/Medium/High m³/min 9.3/11.6/13.9 8.7/10.7/12.6 8.7/11.2/13.6

Sound power level Cooling dBA 49 51Heating dBA 49 51

Sound pressure level Cooling Low/High dBA 27/31 28/33Heating Low/High dBA 27/31 28/33

Control systems Infrared remote control BRC7FA532FWired remote control BRC1D528 / BRC1E53A7 / BRC1E53B7 / BRC1E53C7

Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220

Outdoor unit RXM 35M9 50M9 60M9Dimensions Unit HeightxWidthxDepth mm 550x765x285 735x825x300Weight Unit kg 32 47Sound power level Cooling dBA 61 62 63

Heating dBA 61 62 63Operation range Cooling Ambient Min.~Max. °CDB -10~46

Heating Ambient Min.~Max. °CWB -15~18Refrigerant Type R-32

GWP 675.0Charge kg/TCO2Eq 0.76/0.52 1.40/0.95 1.45/0.98

Piping connections Liquid OD mm 6,35 6,4Gas OD mm 9.50 12.7Piping length OU - IU Max. m 20.0 30Additional refrigerant charge kg/m 0.02 (for piping length exceeding 10m)Level difference IU - OU Max. m 20.0

Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240Current - 50Hz Maximum fuse amps (MFA) A 10 15(1) EER/COP according to Eurovent 2012, for use outside EU only

(2) BYCQ140D7W1: pure white standard panel with grey louvers; BYCQ140D7W1W: pure white standard panel with white louvers; BYCQ140D7GW1: pure white auto cleaning panel.

(3) The BYCQ140D7W1W has white insulations. Be informed that formation of dirt on white insulation is visibly stronger and that it is consequently not advised to install the BYCQ140D7W1W decoration panel in environments exposed to concentrations of dirt.

(4) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

Round flow cassette

360° air discharge for optimum efficiency and comfort

ʯ Combination with split outdoor units is ideal for small retail, offices or residential applications

ʯ Unified indoor unit range for R-32 and R-410A ʯ Combining with R-32 Bluevolution technology, reduces environmental impact with 68% compared to R-410A, leads directly to lower energy consumption thanks to its high energy efficiency and has up to lower 16% refrigerant charge

ʯ Automatic filter cleaning results in higher efficiency & comfort and lower maintenance costs. 2 filters available: standard filter and finer mesh filter (for fine dust applications e.g. clothing shops)

ʯ Two optional intelligent sensors improve energy efficiency and comfort.

ʯ Individual flap control: flexibility to suit every room layout without changing the location of the unit!

ʯ Lowest installation height in the market: 214mm for class 20-63 ʯ Modern style decoration panel is available in 3 different variations: white (RAL9010) with grey louvers, full white (RAL9010) or auto cleaning panel

FCAG-A + RXM-M9 Split

NEW Online controller connection

Page 30: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

30

Fully Flat Cassette Design & Genius in one

Why choose fully flat cassette• Unique design in the market that integrates

fully flat into the ceiling• Advanced technology and top efficiency combined• Most quiet cassette available on the market

ARGUE CARDS

Benefits for the installer › Unique product in the market! › Most quiet unit (25dBA) › The user-friendly remote control, available in several languages, enables the easy set-up of sensor option and control of the individual flap position › Meeting European design taste.

Benefits for the consultant › Unique product in the market! › Blends seamlessly in any modern office interior design › Ideal product to improve BREEAM score/EPBD in combination with Sky Air (FFQ-C) or VRV IV heat pump units (FXZQ-A).

Benefits for the end user › Engineering excellence and unique design in one › Most quiet unit (25dBA) › Perfect working conditions: no more cold draughts › Save up to 27% on your energy bill thanks to the optional sensors › Flexible usage of space and suits any room configuration thanks to individual flap control › User-friendly remote control, available in several languages.

FFA-A

Choice between grey or white panel

Page 31: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

31

Unique design

› Designed by a European design office to fully meet the European taste.

› Fully flat into the ceiling, leaving only 8mm.

Marketing tools › https://www.daikin.eu/en_us/product-group/fully-flat-cassette.html › www.youtube.com/DaikinEurope

› Fully integrated in the one ceiling tile, enabling lights, speakers and sprinklers to be installed in adjoining ceiling tiles.

› Decoration panel available in 2 colours (white and white-silver).

Differentiating in technology

Optional presence sensor › When the room is empty, it can adjust the set temperature or switch off the unit – saving energy.

› When people are detected, the direction of the airflow is adapted to avoid cold draughts being directed towards occupants.

Top efficiency

› Seasonal labels up to *A+ +

› When the room is empty, the sensor option can adjust the set temperature or switch off the unit – saving up to 27% energy. * for FFQ25,35C in combination with RXS25,35L3

Other benefits

› Individual flap control: easily control one or more flaps via the wired remote controller (BRC1E*) when rearranging the room. When fully closing or blocking the flaps, the option “Sealing member of air discharge outlet” is needed.

› Most silent cassette in the market (25dBA), important for office applications.

Optional floor sensor › Detects the temperature difference and re-directs the airflow to ensure even temperature distribution.

Page 32: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

32

Page 33: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

33

BRC1E53A-B-C, BRC7F530W-SRXM20-35M9

FFA-A

Efficiency data FFA + RXM 25A + 25M9 35A + 35M9 50A + 50M9 60A + 60M9Cooling capacity Nom. kW 2.50 3.40 5.00 5.70Heating capacity Nom. kW 3.20 4.20 5.80 7.00Power input Cooling Nom. kW 0.55 0.89 1.54 1.87

Heating Nom. kW 0.82 1.20 1.66 2.05Seasonal efficiency (according to EN14825)

Cooling Energy efficiency class A++ A+Pdesign kW 2.50 3.40 5.00 5.70SEER 6.17 6.38 5.98 5.76Annual energy consumption kWh 142 186 292 347

Heating (Average climate)

Energy efficiency class A+ A A+Pdesign kW 2.31 3.10 3.84 3.96SCOP/A 4.24 4.10 3.90 4.04Annual energy consumption kWh 762 1,058 1,377 1,372

Indoor unit FFA 25A 35A 50A 60ADimensions Unit HeightxWidthxDepth mm 260x575x575Weight Unit kg 16.0 17.5Air filter Type Resin netDecoration panel Model BYFQ60C2W1W/BYFQ60C2W1S/BYFQ60B2W1/BYFQ60B3W1

Colour White (N9.5)/SILVER/White (RAL9010)/WHITE (RAL9010)Dimensions HeightxWidthxDepth mm 46x620x620 / 46x620x620 / 55x700x700 / 55x700x700Weight kg 2.8/2.8/2.7/2.7

Fan Air flow rate Cooling Low/Medium/High m³/min 6.5/8.0/9.0 6.5/8.5/10.0 7.5/10.0/12.0 9.5/12.5/14.5Heating Low/Medium/High m³/min 6.5/8.0/9.0 6.5/8.5/10.0 7.5/10.0/12.0 9.5/12.5/14.5

Sound power level Cooling dBA 48 51 56 60Sound pressure level Cooling Low/High dBA 25.0/31.0 25.0/34.0 27.0/39.0 32.0/43.0

Heating Low/High dBA 25.0/31.0 25.0/34.0 27.0/39.0 32.0/43.0Control systems Infrared remote control BRC7EB530W (standard panel) / BRC7F530W (white panel) / BRC7F530S (grey panel)

Wired remote control BRC1D528 / BRC1E53A7 / BRC1E53B7 / BRC1E53C7Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240

Outdoor unit RXM 25M9 35M9 50M9 60M9Dimensions Unit HeightxWidthxDepth mm 550x765x285 735x825x300Weight Unit kg 32 47Sound power level Cooling dBA 59 61 62 63

Heating dBA 59 61 62 63Operation range Cooling Ambient Min.~Max. °CDB -10~46

Heating Ambient Min.~Max. °CWB -15~18Refrigerant Type R-32

GWP 675.0Charge kg/TCO2Eq 0.76/0.52 1.40/0.95 1.45/0.98

Piping connections Liquid OD mm 6,35 6,4Gas OD mm 9.50 12.7Piping length

OU - IU Max. m 20.0 30System Chargeless m 10.0 -

Additional refrigerant charge kg/m 0.02 (for piping length exceeding 10m)Level difference IU - OU Max. m 20.0

Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240Current - 50Hz Maximum fuse amps (MFA) A 10 15

(1) EER/COP according to Eurovent 2012, for use outside EU only.

(2) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

Fully flat cassette

Unique design in the market that integrates fully flat into the ceiling

ʯ Fully flat integration in standard architectural ceiling tiles, leaving only 8mm

ʯ Remarkable blend of iconic design and engineering excellence with an elegant finish in white or a combination of silver and white

ʯ Unified indoor unit range for R-32 and R-410A ʯ Combining with R-32 Bluevolution technology, reduces environmental impact with 68% compared to R-410A, leads directly to lower energy consumption thanks to its high energy efficiency and has up to lower 16% refrigerant charge

ʯ Two optional intelligent sensors improve energy efficiency and comfort.

ʯ Individual flap control: flexibility to suit every room layout without changing the location of the unit!

ʯ Reduced energy consumption thanks to specially developed small tube heat exchanger, DC fan motor and drain pump

ʯ Optional fresh air intake ʯ Branch duct discharge allows to optimize air distribution in irregular shaped rooms or to supply air to small adjacent rooms

ʯ Standard drain pump with 630mm lift increases flexibility and installation speed

FFA-A + RXM-M9 Split

NEW Online controller connection

Page 34: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

34

ARGUE CARDS

Combination table

BAE20A62 BAE20A82 BAE20A102

Heigth (mm) 212

Width (mm) 764 964 1164

Width (mm) (incl. hanger bracket)

984 1094 1294

Depth (mm) 201

Specifications

Split / Sky Air VRV

FDXM-F3 FXDQ-A3

25 35 50 60 15 20 25 32 40 50 63

BAE20A62

BAE20A82

BAE20A102

UNIQUEPatents

pending

The unique automatic cleaning filter achieves higher efficiency and comfort with lower maintenance costs Reduce running costs

› Automatic filter cleaning ensures low maintenance costs because the filter is always clean

Minimal time required for filter cleaning Ű The dust box can be emptied with a vacuum cleaner for fast and easy cleaning

Ű No more dirty ceilings

Improved indoor air quality › Optimum airflow eliminates draft and insulates sound

Superb reliability

› Prevents clogged filters for seamless operation

Unique technology

Ű Unique and innovative filter technology inspired by the Daikin auto cleaning cassette

airflow direction

Auto cleaning filter for concealed ceiling units

Efficiency profile change for duct indoor unit during operation

start 6 months 12 months

Gradual loss of efficiency due to dirty filter

100%

0%

Up to 20% Energy saved thanks to automatic filter cleaning

How does it work?1 Scheduled automatic filter

cleaning 2 Dust collects in a dust box that’s

integrated into the unit3 The dust can easily be removed

with a vacuum cleaner

Page 35: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

35

ARGUE CARDS

Plug and play

plenum

Zoning box: fully pre-assembled

plenum with dampers etc.

Increase flexiblity: heat or cool multiple rooms with one indoor unit

How does it work?

19°C

20°C

20°C

The zoning kit increases the flexibility of Split, Sky Air and VRV system applications by allowing multiple individually-controlled climate zones to be served by one indoor unit

Connectable to: (preliminary)

› FDXM-F3 › FBQ-D › ADEQ-C › FXDQ-A3 › FXSQ-A

Individual zone thermostats

Blueface - Airzone Main Thermostat

› Color graphic interface for con-trolling zones

› Wired communi-cation

Airzone Zone Thermostat

› Graphic interface with low-energy e-ink screen for controlling zones

› Radio communi-cation

Airzone Zone Thermostat

› Thermostat with buttons for controlling the temperature

› Radio communi-cation

Multi zoning kit for concealed ceiling units

Increased comfort

Ű Increases comfort levels by allowing more individual zone control

- Up to 8 individual zones can be served thanks to separate modulating dampers

- Individual thermostat for room-by-room or zone-by-zone control

Easy to install

Ű Automatic air flow adjustment according to the demand Ű Easy to install, integrates with the Daikin indoor units and system controls

Ű Time saving as plenum comes fully pre-assembled with dampers, and control boards

Ű Reduces the amount of refrigerant required in the installation

Benefits

Page 36: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

36

BRC1E53A-B-CRXM20-35M9

FDXM25-35F3

Efficiency data FDXM + RXM 25F3 + 25M9 35F3 + 35M9 50F3 + 50M9 60F3 + 60M9Cooling capacity Nom. kW 2.40 3.40 5.00 6.00Heating capacity Nom. kW 3.20 4.00 5.80 7.00Power input Cooling Nom. kW 0.64 1.14 1.63 2.05

Heating Nom. kW 0.80 1.15 1.87 2.18Seasonal efficiency (according to EN14825)

Cooling Energy efficiency class A+ A A+ APdesign kW 2.40 3.40 5.00 6.00SEER 5.68 5.26 5.77 5.56Annual energy consumption kWh 148 226 303 315

Heating (Average climate)

Energy efficiency class A+ APdesign kW 2.60 2.90 4.00 4.60SCOP/A 4.24 3.88 3.93 3.80Annual energy consumption kWh 858 1,046 1,424 1,693

Indoor unit FDXM 25F3 35F3 50F3 60F3Dimensions Unit HeightxWidthxDepth mm 200x750x620 200x1,150x620Weight Unit kg 21 28Air filter Type Removable / washableFan Air flow rate Cooling Low/Medium/High m³/min 7.3/8.0/8.7 13.3/14.6/15.8 13.5/14.8/16.0

Heating Low/Medium/High m³/min 7.3/8.0/8.7 13.3/14.6/15.8 13.5/14.8/16.0External static pressure Nom. Pa 30 40

Sound power level Cooling dBA 53 55 56Heating dBA 53 55 56

Sound pressure level Cooling Low/High dBA 27/35 30/38Heating Low/High dBA 27/35 30/38

Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240

Outdoor unit RXM 25M9 35M9 50M9 60M9Dimensions Unit HeightxWidthxDepth mm 550x765x285 735x825x300Weight Unit kg 32 47Sound power level Cooling dBA 59 61 62 63

Heating dBA 59 61 62 63Operation range Cooling Ambient Min.~Max. °CDB -10~46

Heating Ambient Min.~Max. °CWB -15~18Refrigerant Type R-32

GWP 675.0Charge kg/TCO2Eq 0.76/0.52 1.40/0.95 1.45/0.98

Piping connections Liquid OD mm 6,35 6,4Gas OD mm 9.50 12.7Piping length OU - IU Max. m 20.0 30Additional refrigerant charge kg/m 0.02 (for piping length exceeding 10m)Level difference IU - OU Max. m 20.0

Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240Current - 50Hz Maximum fuse amps (MFA) A 10 15

(1) EER/COP according to Eurovent 2012, for use outside EU only,

(2) MFA is used to select the circuit breaker and the ground fault circuit interrupter(earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

Concealed ceiling unit

Compact concealed ceiling unit, with a height of only 200mm

ʯ Invisible unit as the unit is concealed in the ceiling: only the suction and discharge grilles are visible

ʯ Compact dimensions, can easily be mounted in a ceiling void of only 240mm

ʯ Medium external static pressure up to 40Pa facilitates unit use with flexible ducts of varying lengths

ʯ Unified indoor unit range for R-32 and R-410A ʯ Auto cleaning filter option ensures maximum efficiency, comfort and reliability by regular filter cleaning

ʯ Multi zoning kit allows multiple individually-controlled climate zones to be served by one indoor unit

ʯ Online controller (optional): control your indoor from any location with an app, via your local network or internet and keep an overview on your energy consumption

ʯ Low energy consumption thanks to DC fan motor

FDXM-F3 + RXM-M9 Split

NEWwith auto

cleaning and multi zoning

option

NEW Online controller connection

NEW

NEW

Page 37: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

37

NEWwith

multi zoning option

BRC1E53A-B-C, BRC4C65RZAG100-140MV1_MY1

FBA35-50A

Efficiency data FBA + RZAG 71A + 71MV1 100A + 100MV1 125A + 125MV1 140A + 140MV1 71A + 71MY1 100A + 100MY1 125A + 125MY1 140A + 140MY1Cooling capacity Nom. kW 6.80 9.50 12.1 13.4 6.80 9.50 12.1 13.4 Heating capacity Nom. kW 7.50 10.8 13.5 15.5 7.50 10.8 13.5 15.5 Seasonal efficiency (according to EN14825)

Cooling Energy efficiency class A++ - A++ -Pdesign kW 6.80 9.50 12.1 13.4 6.80 9.50 12.1 13.4SEER 6.22 6.47 6.19 6.42 6.22 6.47 6.19 6.42Annual energy consumption kWh 382 514 1,173 1,252 382 514 1,173 1,252

Heating (Average climate)

Energy efficiency class A+ - A+ -Pdesign kW 4.70 7.80 9.52 4.70 7.80 9.52SCOP/A 4.20 4.36 4.12 4.11 4.20 4.36 4.12 4.11Annual energy consumption kWh 1,566 2,505 3,235 3,243 1,566 2,505 3,235 3,243

Indoor unit FBA 71A 100A 125A 140A 71A 100A 125A 140ADimensions Unit HeightxWidthxDepth mm 245x1,000x800 245x1,400x800 245x1,000x800 245x1,400x800Weight Unit kg 35.0 46.0 35.0 46.0Air filter Type Resin netFan Air flow rate Cooling Low/Medium/High m³/min 12.5/15.0/18.0 23.0/26.0/29.0 23.5/29.0/34.0 12.5/15.0/18.0 23.0/26.0/29.0 23.5/29.0/34.0

Heating Low/Medium/High m³/min 12.5/15.0/18.0 23.0/26.0/29.0 23.5/29.0/34.0 12.5/15.0/18.0 23.0/26.0/29.0 23.5/29.0/34.0External static pressure Nom./High Pa 30/150 40/150 50/150 30/150 40/150 50/150

Sound power level Cooling dBA 56 58 62 56 58 62Sound pressure level Cooling Low/High dBA 25.0/30.0 30.0/34.0 32.0/37.0 25.0/30.0 30.0/34.0 32.0/37.0

Heating Low/High dBA 25.0/31.0 30.0/36.0 32.0/38.0 25.0/31.0 30.0/36.0 32.0/38.0Control systems Infrared remote control BRC4C65 / BRC4C66

Wired remote control BRC1D528 / BRC1E53A7 / BRC1E53B7 / BRC1E53C7Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220

Outdoor unit RZAG 71MV1 100MV1 125MV1 140MV1 71MY1 100MY1 125MY1 140MY1Dimensions Unit HeightxWidthxDepth mm 990x940x320 1,430x940x320 990x940x320 1,430x940x320Weight Unit kg 70 92 70 92Sound power level Cooling dBA 64 66 69 70 65 66 69 70Sound pressure level Cooling Nom. dBA 46 47 50 51 46 47 50 51

Heating Nom. dBA 49 51 52 49 51 52Operation range Cooling Ambient Min.~Max. °CDB -20~52

Heating Ambient Min.~Max. °CWB -20~18.0Refrigerant Type/GWP R-32/675

Charge kg/TCO2Eq 2.95/1.99 3.75/2.53 2.95/1.99 3.75/2.53Piping connections Liquid/Gas mm 9,52/15.9

Piping length

OU - IU Max. m 55 85 55 85System Equivalent m 75 100 75 100

Chargeless m 40Additional refrigerant charge kg/m See installation manualLevel difference IU - OU Max. m 30.0

Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3~/50/380-415Current - 50Hz Maximum fuse amps (MFA) A 20 32 16

(1) EER/COP according to Eurovent 2012, for use outside EU only

(2) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

Concealed ceiling unit with medium ESP

Slimmest yet most powerful medium static pressure unit on the market

ʯ Combination with Sky Air Alpha-series ensures best in class quality, highest efficiency and performace

ʯ Slimmest unit in class, only 245mm (300mm built-in height) and therefore narrow ceiling voids are no longer a challenge

ʯ Low operation sound level down to 25dBA ʯ Medium external static pressure up to 150Pa facilitates using flexible ducts of varying lengths

ʯ Unified indoor unit can be combined with R-32 and R-410A outdoor units, symplifying stock

ʯ Combining with R-32 Bluevolution technology, reduces environmental impact with 68% compared to R-410A, leads directly to lower energy consumption thanks to its high energy efficiency and has up to lower 16% refrigerant charge

ʯ Possibility to change ESP via wired remote control allows optimisation of the supply air volume

ʯ Discretely concealed in the ceiling: only the suction and discharge grilles are visible

ʯ Multi zoning kit allows multiple individually-controlled climate zones to be served by one indoor unit

ʯ Reduced energy consumption thanks to specially developed DC fan motor

ʯ Optional fresh air intake

FBA-A + RZAG-MV1/RZAG-MY1

ʯ Flexible installation: air suction direction can be altered from rear to bottom suction and choice between free use or connection to optional suction grilles

ʯ Standard built-in drain pump with 625mm lift increases flexibility and installation speed

NEW Online controller connection

NEW

Page 38: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

38

NEWwith

multi zoning option

BRC1E53A-B-C, BRC4C65RZASG100-140MV1_MY1

FBA35-50A

Efficiency data FBA + RZASG 71A + 71MV1 100A + 100MV1 125A + 125MV1 140A + 140MV1 100A + 100MY1 125A + 125MY1 140A + 140MY1Cooling capacity Nom. kW 6.80 9.50 12.1 13.4 9.50 12.1 13.4 Heating capacity Nom. kW 7.50 10.8 13.5 15.5 10.8 13.5 15.5 Seasonal efficiency (according to EN14825)

Cooling Energy efficiency class A++ A+ - A+ -Pdesign kW 6.80 9.50 12.1 13.4 9.50 12.1 13.4SEER 6.19 5.83 5.27 5.81 5.83 5.27 5.81Annual energy consumption kWh 385 570 1,378 1,384 570 1,378 1,384

Heating (Average climate)

Energy efficiency class A+ A - A -Pdesign kW 4.50 6.00 7.80 6.00 7.80SCOP/A 4.01 3.85 3.63 3.85 3.63 3.85Annual energy consumption kWh 1,571 2,182 2,314 2,836 2,182 2,314 2,836

Indoor unit FBA 71A 100A 125A 140A 100A 125A 140ADimensions Unit HeightxWidthxDepth mm 245x1,000x800 245x1,400x800Weight Unit kg 35.0 46.0Air filter Type Resin netFan Air flow rate Cooling Low/Medium/High m³/min 12.5/15.0/18.0 23.0/26.0/29.0 23.5/29.0/34.0 23.0/26.0/29.0 23.5/29.0/34.0

Heating Low/Medium/High m³/min 12.5/15.0/18.0 23.0/26.0/29.0 23.5/29.0/34.0 23.0/26.0/29.0 23.5/29.0/34.0External static pressure Nom./High Pa 30/150 40/150 50/150 40/150 50/150

Sound power level Cooling dBA 56 58 62 58 62Sound pressure level Cooling Low/High dBA 25.0/30.0 30.0/34.0 32.0/37.0 30.0/34.0 32.0/37.0

Heating Low/High dBA 25.0/31.0 30.0/36.0 32.0/38.0 30.0/36.0 32.0/38.0Control systems Infrared remote control BRC4C65 / BRC4C66

Wired remote control BRC1D528 / BRC1E53A7 / BRC1E53B7 / BRC1E53C7Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220

Outdoor unit RZASG 71MV1 100MV1 125MV1 140MV1 100MY1 125MY1 140MY1Dimensions Unit HeightxWidthxDepth mm 770x900x320 990x940x320Weight Unit kg 60 70 78 70 77Sound power level Cooling dBA 65 70 71 73 70 71 73Sound pressure level Cooling Nom. dBA 46 53 54 53 54

Heating Nom. dBA 47 57Operation range Cooling Ambient Min.~Max. °CDB -15~46

Heating Ambient Min.~Max. °CWB -15~15.5Refrigerant Type/GWP R-32/675

Charge kg/TCO2Eq 2.45/1.65 2.60/1.76 2.90/1.96 2.60/1.76 2.90/1.96Piping connections Liquid/Gas mm 9,52/15.9

Piping length

OU - IU Max. m 50System Equivalent m 70

Chargeless m 30Additional refrigerant charge kg/m See installation manualLevel difference IU - OU Max. m 30.0

Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3~/50/380-415Current - 50Hz Maximum fuse amps (MFA) A 20 25 32 16 20 16

(1) EER/COP according to Eurovent 2012, for use outside EU only

(2) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

Concealed ceiling unit with medium ESP

Slimmest yet most powerful medium static pressure unit on the market

ʯ Combination with Sky Air Advance-series ensures good value for money for all types of commercial applications

ʯ Slimmest unit in class, only 245mm (300mm built-in height) ʯ Low operation sound level down to 25dBA ʯ Medium external static pressure up to 150Pa facilitates using flexible ducts of varying lengths

ʯ Unified indoor unit can be combined with R-32 and R-410A outdoor units, symplifying stock

ʯ Combining with R-32 Bluevolution technology, reduces environmental impact with 68% compared to R-410A

ʯ Possibility to change ESP via wired remote control allows optimisation of the supply air volume

ʯ Discretely concealed in the ceiling: only the suction and discharge grilles are visible

ʯ Multi zoning kit allows multiple individually-controlled climate zones to be served by one indoor unit

FBA-A + RZASG-MV1/RZASG-MY1

Optimised supply air volume

Automatically selects the most appropriate fan curve to achieve the units’ nominal air flow within ±10%

Why?

After installation the real ducting will frequently differ from the initially calculated air flow resistance the real air flow may be much lower or higher than nominal, leading to a lack of capacity or uncomfortable air temperature

Automatic Airflow Adjustment function will adapt the unit’s fan speed to any ducting automatically (10 or more fan curves are available on every model), making installation much faster

External static pressure (Pa)

Air flow (rated)

Air flow (actual)

Duct resistance curves

Air flow (with automatic adjustment)

±10% Air flow (m3/min)

Fan characteristiccurves

NEW Online controller connection

NEW

Page 39: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

39

NEWwith

multi zoning option

BRC1E53A-B-C, BRC4C65AZAS71MV1_MY1

FBA35-50A

Efficiency data FBA + AZAS 71A + 71M2V1B 100A + 100M7V1B 125A + 125M7V1B 140A + 140M7V1B 100A + 100M7Y1B 125A + 125M7Y1B 140A + 140M7Y1BCooling capacity Nom. kW 6.80 9.50 12.1 13.4 9.50 12.1 13.4 Heating capacity Nom. kW 7.50 10.8 13.5 15.5 10.8 13.5 15.5 Seasonal efficiency (according to EN14825)

Cooling Energy efficiency class A - A -Pdesign kW 6.80 9.50 12.1 13.0 9.50 12.1 13.0SEER 5.57 5.25 4.85 5.50 5.25 4.85 5.50Annual energy consumption kWh 427 633 1,497 1,418 633 1,497 1,418

Heating (Average climate)

Energy efficiency class A - A -Pdesign kW 4.50 6.00 7.80 6.00 7.80SCOP/A 3.81 3.55 3.85 3.81 3.55 3.85Annual energy consumption kWh 1,654 2,205 2,366 2,836 2,205 2,366 2,836

Indoor unit FBA 71A 100A 125A 140A 100A 125A 140ADimensions Unit HeightxWidthxDepth mm 245x1,000x800 245x1,400x800Weight Unit kg 35.0 46.0Air filter Type Resin netFan Air flow rate Cooling Low/Medium/High m³/min 12.5/15.0/18.0 23.0/26.0/29.0 23.5/29.0/34.0 23.0/26.0/29.0 23.5/29.0/34.0

Heating Low/Medium/High m³/min 12.5/15.0/18.0 23.0/26.0/29.0 23.5/29.0/34.0 23.0/26.0/29.0 23.5/29.0/34.0External static pressure Nom./High Pa 30/150 40/150 50/150 40/150 50/150

Sound power level Cooling dBA 56 58 62 58 62Sound pressure level Cooling Low/High dBA 25.0/30.0 30.0/34.0 32.0/37.0 30.0/34.0 32.0/37.0

Heating Low/High dBA 25.0/31.0 30.0/36.0 32.0/38.0 30.0/36.0 32.0/38.0Control systems Infrared remote control BRC4C65 / BRC4C66

Wired remote control BRC1D528 / BRC1E53A7 / BRC1E53B7 / BRC1E53C7Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220

Outdoor unit AZAS 71M2V1B 100M7V1B 125M7V1B 140M7V1B 100M7Y1B 125M7Y1B 140M7Y1BDimensions Unit HeightxWidthxDepth mm 770x900x320 990x940x320Weight Unit kg 60 70 78 70 77Sound power level Cooling dBA 65 70 71 73 70 71 73Sound pressure level Cooling Nom. dBA 46 53 54 53 54

Heating Nom. dBA 47 57Operation range Cooling Ambient Min.~Max. °CDB -5~46

Heating Ambient Min.~Max. °CWB -15~15.5Refrigerant Type/GWP R-32/675

Charge kg/TCO2Eq 2.45/1.65 2.60/1.76 2.90/1.96 2.60/1.76 2.90/1.96Piping connections Liquid/Gas mm 9,52/15.9

Piping length

OU - IU Max. m 30System Equivalent m 50

Chargeless m 30Additional refrigerant charge kg/m See installation manualLevel difference IU - OU Max. m 30.0

Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3~/50/380-415Current - 50Hz Maximum fuse amps (MFA) A 20 25 32 16 20

(1) EER/COP according to Eurovent 2012, for use outside EU only

(2) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

Concealed ceiling unit with medium ESP

Slimmest yet most powerful medium static pressure unit on the market

ʯ Ideal solution for small businesses and shops ʯ Slimmest unit in class, only 245mm (300mm built-in height) ʯ Low operation sound level down to 25dBA ʯ Medium external static pressure up to 150Pa facilitates using flexible ducts of varying lengths

ʯ Unified indoor unit can be combined with R-32 and R-410A outdoor units, symplifying stock

ʯ Combining with R-32 Bluevolution technology, reduces environmental impact with 68% compared to R-410A

ʯ Possibility to change ESP via wired remote control allows optimisation of the supply air volume

ʯ Discretely concealed in the ceiling: only the suction and discharge grilles are visible

ʯ Multi zoning kit allows multiple individually-controlled climate zones to be served by one indoor unit

FBA-A + AZAS-MV1/AZAS-MY1

NEW Online controller connectionNEW

Page 40: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

40

BRC1E53A-B-C, BRC4C65RXM20-35M9

FBA35-50A

Efficiency data FBA + RXM 35A + 35M9 50A + 50M9 60A + 60M9Cooling capacity Nom. kW 3.40 5.00 5.70Heating capacity Nom. kW 4.00 5.50 7.00Power input Cooling Nom. kW 0.85 1.41 1.64

Heating Nom. kW 1.00 1.44 1.89Seasonal efficiency (according to EN14825)

Cooling Energy efficiency class A++ A+Pdesign kW 3.40 5.00 5.70SEER 6.23 6.27 5.91Annual energy consumption kWh 191 279 337

Heating (Average climate)

Energy efficiency class A+Pdesign kW 2.90 4.40 4.60SCOP/A 4.07 4.06 4.01Annual energy consumption kWh 996 1,517 1,607

Indoor unit FBA 35A 50A 60ADimensions Unit HeightxWidthxDepth mm 245x700x800 245x1,000x800Weight Unit kg 28.0 35.0Air filter Type Resin netFan Air flow rate Cooling Low/Medium/High m³/min 10.5/12.5/15.0 12.5/15.0/18.0

Heating Low/Medium/High m³/min 10.5/12.5/15.0 12.5/15.0/18.0External static pressure Nom./High Pa 30/150

Sound power level Cooling dBA 60 56Sound pressure level Cooling Low/High dBA 29.0/35.0 25.0/30.0

Heating Low/High dBA 29.0/37.0 25.0/31.0Control systems Infrared remote control BRC4C65 / BRC4C66

Wired remote control BRC1D528 / BRC1E53A7 / BRC1E53B7 / BRC1E53C7Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220

Outdoor unit RXM 35M9 50M9 60M9Dimensions Unit HeightxWidthxDepth mm 550x765x285 735x825x300Weight Unit kg 32 47Sound power level Cooling dBA 61 62 63

Heating dBA 61 62 63Operation range Cooling Ambient Min.~Max. °CDB -10~46

Heating Ambient Min.~Max. °CWB -15~18Refrigerant Type R-32

GWP 675.0Charge kg/TCO2Eq 0.76/0.52 1.40/0.95 1.45/0.98

Piping connections Liquid OD mm 6,35 6,4Gas OD mm 9.50 12.7Piping length OU - IU Max. m 20.0 30Additional refrigerant charge kg/m 0.02 (for piping length exceeding 10m)Level difference IU - OU Max. m 20.0

Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240Current - 50Hz Maximum fuse amps (MFA) A 10 15

(1) EER/COP according to Eurovent 2012, for use outside EU only

(2) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

Concealed ceiling unit with medium ESPSlimmest yet most powerful medium static pressure unit on the market

ʯ Combination with split outdoor units is ideal for small retail, offices or residential applications

ʯ Slimmest unit in class, only 245mm (300mm built-in height) ʯ Low operation sound level down to 25dBA ʯ Medium external static pressure up to 150Pa facilitates using flexible ducts of varying lengths

ʯ Unified indoor unit can be combined with R-32 and R-410A outdoor units, symplifying stock

ʯ Combining with R-32 Bluevolution technology, reduces environmental impact with 68% compared to R-410A

ʯ Possibility to change ESP via wired remote control allows optimisation of the supply air volume

ʯ Discretely concealed in the ceiling: only the suction and discharge grilles are visible

ʯ Multi zoning kit allows multiple individually-controlled climate zones to be served by one indoor unit

FBA-A + RXM-M9 Split

NEWwith

multi zoning option

NEW Online controller connection

NEW

Optimised supply air volume

Automatically selects the most appropriate fan curve to achieve the units’ nominal air flow within ±10%

Why?

After installation the real ducting will frequently differ from the initially calculated air flow resistance the real air flow may be much lower or higher than nominal, leading to a lack of capacity or uncomfortable air temperature

Automatic Airflow Adjustment function will adapt the unit’s fan speed to any ducting automatically (10 or more fan curves are available on every model), making installation much faster

External static pressure (Pa)

Air flow (rated)

Air flow (actual)

Duct resistance curves

Air flow (with automatic adjustment)

±10% Air flow (m3/min)

Fan characteristiccurves

Page 41: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

41

BRC1E53A-B-C

FDA125A

Sky Air Alpha-series Sky Air Advance-seriesEfficiency data FDA + RZAG/RZASG 125A + 125MV1 125A + 125MY1 125A + 125MV1 125A + 125MY1Cooling capacity Nom. kW 12.1Heating capacity Nom. kW 13.5Seasonal efficiency (according to EN14825)

Cooling Energy efficiency class - - - -Pdesign kW 12,1SEER 6,59 5,03Annual energy consumption kWh 1102 1444

Heating (Average climate)

Energy efficiency class - - - -Pdesign kW 9,52 6,00SCOP/A 4,08 3,58Annual energy consumption kWh 3267 2346

Indoor unit FDA 125ADimensions Unit HeightxWidthxDepth mm 300x1,400x700Required ceiling void > mm 350Weight Unit kg 45Decoration panel Model BYBS125DJW1

Colour White (10Y9/0.5)Dimensions HeightxWidthxDepth mm 55x1,500x500Weight kg 6.5

Air filter Type Resin net with mold resistanceFan - Air flow rate Cooling High/Low m³/min 39/28

Heating High/Low m³/min 39/28Fan - External static pressure High/Nom./Maximum available/High Pa 200/50/-Sound power level Cooling dBA 66Sound pressure level Cooling High/Low dBA 40/33

Heating High/Low dBA 40/33Refrigerant Type R-32 / R-410AControl systems Infrared remote control BRC4C65

Wired remote control BRC1D52 / BRC1E53A / BRC1E53B / BRC1E53CPower supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220

Outdoor unit RZAG/RZASG 125MV1 125MY1 125MV1 125MY1Dimensions Unit HeightxWidthxDepth mm 1,430x940x320 1,430x940x320 990x940x320 990x940x320Weight Unit kg 92 92 70 70Sound power level Cooling dBA 69 69 71 71Sound pressure level Cooling Nom. dBA 50 50 53 53

Heating Nom. dBA 52 52 57 57Operation range Cooling Ambient Min.~Max. °CDB -20~52 -15~46

Heating Ambient Min.~Max. °CWB -20~18 -15~15,5Refrigerant Type R-32

Charge kg 3,75 2,6TCO₂eq 2,53 1,76

GWP 675Piping connections Piping length OU - IU Max. m 85 50

System Chargeless m 40 30Power supply Phase / Frequency / Voltage Hz / V 1~/50/220-240 3N~/50 / 380-415 1~/50/220-240 3N~/50 / 380-415

(1) EER/COP according to Eurovent 2012, for use outside EU only

(2) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

Concealed ceiling unit with high ESP

ESP up to 200, ideal for large sized spaces

ʯ Unified range for R-32 and R-410A simplifying stock ʯ High external static pressure up to 200Pa facilitates extensive duct and grille network

ʯ Possibility to change ESP via wired remote control allows optimisation of the supply air volume

ʯ Discretely concealed in the ceiling: only the suction and discharge grilles are visible

ʯ Reduced energy consumption thanks to specially developed DC fan motor

ʯ No optional adapter needed for DIII-connection, link your unit into the wider building management system.

ʯ Flexible installation, as the air suction direction can be altered from rear to bottom suction

ʯ Standard built-in drain pump with 625mm lift increases flexibility and installation speed

FDA-A + RZAG-MV1/MY1, RZASG-MV1/MY1

BRC4C65RZAG100-140MV1/MY1

NEW Online controller connection

Page 42: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

42

BRC1E53A-B-C, BRC7E518RZAG100-140MV1_MY1

FAA100A

Efficiency data FAA + RZAG 71A + 71MV1 100A + 100MV1 71A + 71MY1 100A + 100MY1Cooling capacity Nom. kW 6.80 9.50 6.80 9.50 Heating capacity Nom. kW 7.50 10.8 7.50 10.8 Seasonal efficiency (according to EN14825)

Cooling Energy efficiency class A++Pdesign kW 6.80 9.50 6.80 9.50SEER 6.58 6.42 6.58 6.42Annual energy consumption kWh 362 518 362 518

Heating (Average climate)

Energy efficiency class A+Pdesign kW 4.70 7.80 4.70 7.80SCOP/A 4.02 4.01 4.02 4.01Annual energy consumption kWh 1,637 2,723 1,637 2,723

Indoor unit FAA 71A 100A 71A 100ADimensions Unit HeightxWidthxDepth mm 290x1,050x238 340x1,200x240 290x1,050x238 340x1,200x240Weight Unit kg 13.0 17.0 13.0 17.0Air filter Type -Fan Air flow rate Cooling Low/Medium/High m³/min 14.0/16/18.0 19.0/23/26.0 14.0/16/18.0 19.0/23/26.0

Heating Low/Medium/High m³/min 14.0/16.0/18.0 19.0/23.0/26.0 14.0/16.0/18.0 19.0/23.0/26.0Sound power level Cooling dBA 61 65 61 65

Heating dBA 61 65 61 65Sound pressure level Cooling Low/High dBA 40/45 41/49 40/45 41/49

Heating Low/High dBA 40/45 41/49 40/45 41/49Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240

Outdoor unit RZAG 71MV1 100MV1 71MY1 100MY1Dimensions Unit HeightxWidthxDepth mm 990x940x320 1,430x940x320 990x940x320 1,430x940x320Weight Unit kg 70 92 70 92Sound power level Cooling dBA 64 66 65 66Sound pressure level Cooling Nom. dBA 46 47 46 47

Heating Nom. dBA 49 51 49 51Operation range Cooling Ambient Min.~Max. °CDB -20~52

Heating Ambient Min.~Max. °CWB -20~18Refrigerant Type/GWP R-32/675

Charge kg/TCO2Eq 2.95/1.99 3.75/2.53 2.95/1.99 3.75/2.53Piping connections Liquid/Gas mm 9,52/15.9

Piping length

OU - IU Max. m 55 85 55 85System Equivalent m 75 100 75 100

Chargeless m 40Additional refrigerant charge kg/m See installation manualLevel difference IU - OU Max. m 30.0

Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3~/50/380-415Current - 50Hz Maximum fuse amps (MFA) A 20 32 16

(1) EER/COP according to Eurovent 2012, for use outside EU only

(2) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

Wall mounted unit

For rooms with no false ceilings nor free floor space

ʯ Combination with Sky Air Alpha-series ensures best in class quality, highest efficiency and performance

ʯ Flat, stylish front panel blends easily within any interior décor and is easier to clean

ʯ Can easily be installed in both new and refurbishment projects ʯ Unified indoor unit range for R-32 and R-410A ʯ Combining with R-32 Bluevolution technology, reduces environmental impact with 68% compared to R-410A, leads directly to lower energy consumption thanks to its high energy efficiency and has up to lower 16% refrigerant charge

ʯ Reduced energy consumption thanks to specially developed DC fan motor

ʯ The air is comfortably spread up- and downwards thanks to 5 different discharge angles that can be programmed via the remote control

ʯ Maintenance operations can be performed easily from the front of the unit

ʯ Flexible to install as the largest casing only weighs 17kg and piping connection can be done at the bottom, left or right of the unit

FAA-A + RZAG-MV1/RZAG-MY1

NEW Online controller connection

Page 43: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

43

BRC1E53A-B-C, BRC7E518RZASG100-140MV1_MY1

FAA100A

Efficiency data FAA + RZASG 71A + 71MV1 100A + 100MV1 100A + 100MY1Cooling capacity Nom. kW 6.80 9.50 Heating capacity Nom. kW 7.50 10.8 Seasonal efficiency (according to EN14825)

Cooling Energy efficiency class A++ A+Pdesign kW 6.80 9.50SEER 6.41 5.83Annual energy consumption kWh 371 570

Heating (Average climate)

Energy efficiency class APdesign kW 4.50 6.00SCOP/A 3.90 3.85Annual energy consumption kWh 1,615 2,182

Indoor unit FAA 71A 100A 100ADimensions Unit HeightxWidthxDepth mm 290x1,050x238 340x1,200x240Weight Unit kg 13.0 17.0Air filter Type -Fan Air flow rate Cooling Low/Medium/High m³/min 14.0/16/18.0 19.0/23/26.0

Heating Low/Medium/High m³/min 14.0/16.0/18.0 19.0/23.0/26.0Sound power level Cooling dBA 61 65

Heating dBA 61 65Sound pressure level Cooling Low/High dBA 40/45 41/49

Heating Low/High dBA 40/45 41/49Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240

Outdoor unit RZASG 71MV1 100MV1 100MY1Dimensions Unit HeightxWidthxDepth mm 770x900x320 990x940x320Weight Unit kg 60 70Sound power level Cooling dBA 65 70Sound pressure level Cooling Nom. dBA 46 53

Heating Nom. dBA 47 57Operation range Cooling Ambient Min.~Max. °CDB -15~46

Heating Ambient Min.~Max. °CWB -15~15,5Refrigerant Type/GWP R-32/675

Charge kg/TCO2Eq 2.45/1.65 2.60/1.76Piping connections Liquid/Gas mm 9,52/15.9

Piping length

OU - IU Max. m 50System Equivalent m 70

Chargeless m 30Additional refrigerant charge kg/m See installation manualLevel difference IU - OU Max. m 30.0

Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3~/50/380-415Current - 50Hz Maximum fuse amps (MFA) A 20 25 16

(1) EER/COP according to Eurovent 2012, for use outside EU only

(2) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

Wall mounted unit

For rooms with no false ceilings nor free floor space

ʯ Combination with Sky Air Advance-series ensures good value for money for all types of commercial applications

ʯ Flat, stylish front panel blends easily within any interior décor and is easier to clean

ʯ Can easily be installed in both new and refurbishment projects ʯ Unified indoor unit range for R-32 and R-410A ʯ Combining with R-32 Bluevolution technology, reduces environmental impact with 68% compared to R-410A, leads directly to lower energy consumption thanks to its high energy efficiency and has up to lower 16% refrigerant charge

FAA-A + RZASG-MV1/RZASG-MY1

NEW Online controller connection

Page 44: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

44

BRC1E52A-B, BRC7E518AZAS71MV1_MY1

FAA100A

Efficiency data FAA + AZAS 71A + 71M2V1B 100A + 100M7V1B 100A + 100M7Y1BCooling capacity Nom. kW 6.80 9.50 Heating capacity Nom. kW 7.50 10.8 Seasonal efficiency (according to EN14825)

Cooling Energy efficiency class A+ APdesign kW 6.80 9.50SEER 5.77 5.25Annual energy consumption kWh 412 633

Heating (Average climate)

Energy efficiency class APdesign kW 4.50 6.00SCOP/A 3.81Annual energy consumption kWh 1,654 2,205

Indoor unit FAA 71A 100A 100ADimensions Unit HeightxWidthxDepth mm 290x1,050x238 340x1,200x240Weight Unit kg 13.0 17.0Air filter Type -Fan Air flow rate Cooling Low/Medium/High m³/min 14.0/16/18.0 19.0/23/26.0

Heating Low/Medium/High m³/min 14.0/16.0/18.0 19.0/23.0/26.0Sound power level Cooling dBA 61 65

Heating dBA 61 65Sound pressure level Cooling Low/High dBA 40/45 41/49

Heating Low/High dBA 40/45 41/49Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240

Outdoor unit AZAS 71M2V1B 100M7V1B 100M7Y1BDimensions Unit HeightxWidthxDepth mm 770x900x320 990x940x320Weight Unit kg 60 70Sound power level Cooling dBA 65 70Sound pressure level Cooling Nom. dBA 46 53

Heating Nom. dBA 47 57Operation range Cooling Ambient Min.~Max. °CDB -5~46

Heating Ambient Min.~Max. °CWB -15~15,5Refrigerant Type/GWP R-32/675

Charge kg/TCO2Eq 2.45/1.65 2.60/1.76Piping connections Liquid/Gas mm 9,52/15.9

Piping length

OU - IU Max. m 30System Equivalent m 50

Chargeless m 30Additional refrigerant charge kg/m See installation manualLevel difference IU - OU Max. m 30.0

Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3~/50/380-415Current - 50Hz Maximum fuse amps (MFA) A 20 25 16

(1) EER/COP according to Eurovent 2012, for use outside EU only

(2) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

Wall mounted unit

For rooms with no false ceilings nor free floor space

ʯ Ideal solution for small businesses and shops ʯ Flat, stylish front panel blends easily within any interior décor and is easier to clean

ʯ Can easily be installed in both new and refurbishment projects ʯ Unified indoor unit range for R-32 and R-410A ʯ Combining with R-32 Bluevolution technology, reduces environmental impact with 68% compared to R-410A, leads directly to lower energy consumption thanks to its high energy efficiency and has up to lower 16% refrigerant charge

FAA-A + AZAS-MV1/AZAS-MY1

NEW Online controller connection

Page 45: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

45

Page 46: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

46

BRC1E53A-B-C, BRC7G53RZAG100-140MV1_MY1

FHA60-71A

Efficiency data FHA + RZAG 71A + 71MV1 100A + 100MV1 125A + 125MV1 140A + 140MV1 71A + 71MY1 100A + 100MY1 125A + 125MY1 140A + 140MY1Cooling capacity Nom. kW 6.80 9.50 12.1 13.4 6.80 9.50 12.1 13.4 Heating capacity Nom. kW 7.50 10.8 13.5 15.5 7.50 10.8 13.5 15.5 Seasonal efficiency (according to EN14825)

Cooling Energy efficiency class A++ - A++ -Pdesign kW 6.80 9.50 12.1 13.4 6.80 9.50 12.1 13.4SEER 7.11 6.42 8.22 6.42 7.11 6.42 8.22 6.42Annual energy consumption kWh 335 518 883 1,252 335 518 883 1,252

Heating (Average climate)

Energy efficiency class A+ A++ - A+ A++ -Pdesign kW 4.70 7.80 9.52 4.70 7.80 9.52SCOP/A 4.32 4.61 4.09 4.30 4.32 4.61 4.09 4.30Annual energy consumption kWh 1,523 2,369 3,259 3,100 1,523 2,369 3,259 3,100

Indoor unit FHA 71A 100A 125A 140A 71A 100A 125A 140ADimensions Unit HeightxWidthxDepth mm 235x1,270x690 235x1,590x690 235x1,270x690 235x1,590x690Weight Unit kg 32.0 38.0 32.0 38.0Air filter Type Resin netFan Air flow rate Cooling Low/Medium/High m³/min 14.0/17.0/20.5 20.0/24.0/28.0 23.0/27.0/31.0 24.0/29.0/34.0 14.0/17.0/20.5 20.0/24.0/28.0 23.0/27.0/31.0 24.0/29.0/34.0

Heating Low/Medium/High m³/min 14.0/17.0/20.5 20.0/24.0/28.0 23.0/27.0/31.0 24.0/29.0/34.0 14.0/17.0/20.5 20.0/24.0/28.0 23.0/27.0/31.0 24.0/29.0/34.0Sound power level Cooling dBA 55 60 62 64 55 60 62 64Sound pressure level Cooling Low/High dBA 34/38 34/42 37/44 38/46 34/38 34/42 37/44 38/46

Heating Nom./High dBA 36/38 38/42 41/44 42/46 36/38 38/42 41/44 42/46Control systems Infrared remote control BRC7GA53 / BRC7GA56

Wired remote control BRC1E53A7 / BRC1E53B7 / BRC1E53C7 / BRC1D528 / BRC1E51A7Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240

Outdoor unit RZAG 71MV1 100MV1 125MV1 140MV1 71MY1 100MY1 125MY1 140MY1Dimensions Unit HeightxWidthxDepth mm 990x940x320 1,430x940x320 990x940x320 1,430x940x320Weight Unit kg 70 92 70 92Sound power level Cooling dBA 64 66 69 70 65 66 69 70Sound pressure level Cooling Nom. dBA 46 47 50 51 46 47 50 51

Heating Nom. dBA 49 51 52 49 51 52Operation range Cooling Ambient Min.~Max. °CDB -20~52

Heating Ambient Min.~Max. °CWB -20~18Refrigerant Type/GWP R-32/675

Charge kg/TCO2Eq 2.95/1.99 3.75/2.53 2.95/1.99 3.75/2.53Piping connections Liquid/Gas mm 9,52/15.9

Piping length

OU - IU Max. m 55 85 55 85System Equivalent m 75 100 75 100

Chargeless m 40Additional refrigerant charge kg/m See installation manualLevel difference IU - OU Max. m 30.0

Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3~/50/380-415Current - 50Hz Maximum fuse amps (MFA) A 20 32 16

(1) EER/COP according to Eurovent 2012, for use outside EU only

(2) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

Ceiling suspended unit

For wide rooms with no false ceilings nor free floor space

ʯ Combination with Sky Air Alpha-series ensures best in class quality, highest efficiency and performance

ʯ Ideal for comfortable air flow in wide rooms thanks to Coanda effect: up to 100° discharge angle

ʯ Even rooms with ceilings up to 3.8m can be heated up or cooled down very easily without capacity loss

ʯ Can easily be installed in both new and refurbishment projects ʯ Unified indoor unit range for R-32 and R-410A ʯ Combining with R-32 Bluevolution technology, reduces environmental impact with 68% compared to R-410A, leads directly to lower energy consumption thanks to its high energy efficiency and has up to lower 16% refrigerant charge

ʯ Can easily be mounted in corners and narrow spaces, as it only needs 30mm lateral service space

30 or more 30 or more(Service space) (Service space) Obstruction

Air inlet

Air outlet

ʯ Reduced energy consumption thanks to specially developed small tube heat exchanger, DC fan motor and drain pump

FHA-A + RZAG-MV1/RZAG-MY1

ʯ 5 different fan speeds available for maximum comfort ʯ Stylish unit blends easily with any interior. The flaps close entirely when the unit is not operating and there are no air intake grilles visible

NEW Online controller connection

Page 47: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

47

BRC1E53A-B-C, BRC7G53RZASG100-140MV1_MY1

FHA60-71A

Efficiency data FHA + RZASG 71A + 71MV1 100A + 100MV1 125A + 125MV1 140A + 140MV1 100A + 100MY1 125A + 125MY1 140A + 140MY1Cooling capacity Nom. kW 6.80 9.50 12.1 13.4 9.50 12.1 13.4 Heating capacity Nom. kW 7.50 10.8 13.5 15.5 10.8 13.5 15.5 Seasonal efficiency (according to EN14825)

Cooling Energy efficiency class A+ - A+ -Pdesign kW 6.80 9.50 12.1 13.4 9.50 12.1 13.4SEER 5.95 5.83 5.60 5.88 5.83 5.60 5.88Annual energy consumption kWh 400 570 1,297 1,368 570 1,297 1,368

Heating (Average climate)

Energy efficiency class A - A -Pdesign kW 4.50 6.00 7.80 6.00 7.80SCOP/A 3.90 3.91 3.83 3.81 3.91 3.83 3.81Annual energy consumption kWh 1,616 2,148 2,193 2,866 2,148 2,193 2,866

Indoor unit FHA 71A 100A 125A 140A 100A 125A 140ADimensions Unit HeightxWidthxDepth mm 235x1,270x690 235x1,590x690Weight Unit kg 32.0 38.0Air filter Type Resin netFan Air flow rate Cooling Low/Medium/High m³/min 14.0/17.0/20.5 20.0/24.0/28.0 23.0/27.0/31.0 24.0/29.0/34.0 20.0/24.0/28.0 23.0/27.0/31.0 24.0/29.0/34.0

Heating Low/Medium/High m³/min 14.0/17.0/20.5 20.0/24.0/28.0 23.0/27.0/31.0 24.0/29.0/34.0 20.0/24.0/28.0 23.0/27.0/31.0 24.0/29.0/34.0Sound power level Cooling dBA 55 60 62 64 60 62 64Sound pressure level Cooling Low/High dBA 34/38 34/42 37/44 38/46 34/42 37/44 38/46

Heating Nom./High dBA 36/38 38/42 41/44 42/46 38/42 41/44 42/46Control systems Infrared remote control BRC7GA53 / BRC7GA56

Wired remote control BRC1E53A7 / BRC1E53B7 / BRC1E53C7 / BRC1D528 / BRC1E51A7Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240

Outdoor unit RZASG 71MV1 100MV1 125MV1 140MV1 100MY1 125MY1 140MY1Dimensions Unit HeightxWidthxDepth mm 770x900x320 990x940x320Weight Unit kg 60 70 78 70 77Sound power level Cooling dBA 65 70 71 73 70 71 73Sound pressure level Cooling Nom. dBA 46 53 54 53 54

Heating Nom. dBA 47 57Operation range Cooling Ambient Min.~Max. °CDB -15~46

Heating Ambient Min.~Max. °CWB -15~15.5Refrigerant Type/GWP R-32/675

Charge kg/TCO2Eq 2.45/1.65 2.60/1.76 2.90/1.96 2.60/1.76 2.90/1.96Piping connections Liquid/Gas mm 9,52/15.9

Piping length

OU - IU Max. m 50System Equivalent m 70

Chargeless m 30Additional refrigerant charge kg/m See installation manualLevel difference IU - OU Max. m 30.0

Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3~/50/380-415Current - 50Hz Maximum fuse amps (MFA) A 20 25 32 16

(1) EER/COP according to Eurovent 2012, for use outside EU only

(2) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

Ceiling suspended unit

For wide rooms with no false ceilings nor free floor space

ʯ Combination with Sky Air Advance-series ensures good value for money for all types of commercial applications

ʯ Ideal for comfortable air flow in wide rooms thanks to Coanda effect: up to 100° discharge angle

ʯ Even rooms with ceilings up to 3.8m can be heated up or cooled down very easily without capacity loss

ʯ Can easily be installed in both new and refurbishment projects ʯ Unified indoor unit range for R-32 and R-410A ʯ Combining with R-32 Bluevolution technology, reduces environmental impact with 68% compared to R-410A, leads directly to lower energy consumption thanks to its high energy efficiency and has up to lower 16% refrigerant charge

FHA-A + RZASG-MV1/RZASG-MY1

NEW Online controller connection

Page 48: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

48

BRC1E53A-B-C, BRC7G53RXM20-35M9

FHA60-71A

Efficiency data FHA + RXM 35A + 35M9 50A + 50M9 60A + 60M9Cooling capacity Nom. kW 3.40 5.00 5.70Heating capacity Nom. kW 4.00 6.00 7.20Power input Cooling Nom. kW 0.91 1.56 1.73

Heating Nom. kW 0.98 1.79 2.17Seasonal efficiency (according to EN14825)

Cooling Energy efficiency class A++ A+Pdesign kW 3.40 5.00 5.70SEER 6.24 5.92 6.08Annual energy consumption kWh 191 295 328

Heating (Average climate)

Energy efficiency class A+ APdesign kW 3.10 4.35 4.71SCOP/A 4.43 3.86 3.87Annual energy consumption kWh 979 1,578 1,704

Indoor unit FHA 35A 50A 60ADimensions Unit HeightxWidthxDepth mm 235x960x690 235x1,270x690Weight Unit kg 24.0 25.0 31.0Air filter Type Resin netFan Air flow rate Cooling Low/Medium/High m³/min 10.0/11.5/14.0 10.0/12.0/15.0 11.5/15.0/19.5

Heating Low/Medium/High m³/min 10.0/11.5/14.0 10.0/12.0/15.0 11.5/15.0/19.5Sound power level Cooling dBA 53 54Sound pressure level Cooling Low/High dBA 31/36 32/37 33/37

Heating Nom./High dBA 34/36 35/37Control systems Infrared remote control BRC7GA53 / BRC7GA56

Wired remote control BRC1E53A7 / BRC1E53B7 / BRC1E53C7 / BRC1D528 / BRC1E51A7Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240

Outdoor unit RXM 35M9 50M9 60M9Dimensions Unit HeightxWidthxDepth mm 550x765x285 735x825x300Weight Unit kg 32 47Sound power level Cooling dBA 61 62 63

Heating dBA 61 62 63Operation range Cooling Ambient Min.~Max. °CDB -10~46

Heating Ambient Min.~Max. °CWB -15~18Refrigerant Type R-32

GWP 675.0Charge kg/TCO2Eq 0.76/0.52 1.40/0.95 1.45/0.98

Piping connections Liquid OD mm 6,35 6,4Gas OD mm 9.50 12.7Piping length OU - IU Max. m 20.0 30Additional refrigerant charge kg/m 0.02 (for piping length exceeding 10m)Level difference IU - OU Max. m 20.0

Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240Current - 50Hz Maximum fuse amps (MFA) A 10 15

(1) EER/COP according to Eurovent 2012, for use outside EU only

(2) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

Ceiling suspended unit

For wide rooms with no false ceilings nor free floor space

ʯ Combination with split outdoor units is ideal for small retail, offices or residential applications

ʯ Ideal for comfortable air flow in wide rooms thanks to Coanda effect: up to 100° discharge angle

ʯ Even rooms with ceilings up to 3.8m can be heated up or cooled down very easily without capacity loss

ʯ Can easily be installed in both new and refurbishment projects ʯ Unified indoor unit range for R-32 and R-410A ʯ Combining with R-32 Bluevolution technology, reduces environmental impact with 68% compared to R-410A, leads directly to lower energy consumption thanks to its high energy efficiency and has up to lower 16% refrigerant charge

FHA-A + RXM-M9 Split

NEW Online controller connection

Page 49: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

49

Page 50: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

50

BRC1E52A-B, BRC7CB58RZAG100-140MV1_MY1

FUA-A

Efficiency data FUA + RZAG 71A + 71MV1 100A + 100MV1 125A + 125MV1 71A + 71MY1 100A + 100MY1 125A + 125MY1Cooling capacity Nom. kW 6.80 9.50 12.1 6.80 9.50 12.1 Heating capacity Nom. kW 7.50 10.8 13.5 7.50 10.8 13.5 Seasonal efficiency (according to EN14825)

Cooling Energy efficiency class A++ - A++ -Pdesign kW 6.80 9.50 12.1 6.80 9.50 12.1SEER 7.02 6.42 6.39 7.02 6.42 6.39Annual energy consumption kWh 339 518 1,136 339 518 1,136

Heating (Average climate)

Energy efficiency class A+ - A+ -Pdesign kW 4.70 7.80 9.52 4.70 7.80 9.52SCOP/A 4.20 4.50 4.26 4.20 4.50 4.26Annual energy consumption kWh 1,567 2,427 3,129 1,567 2,427 3,129

Indoor unit FUA 71A 100A 125A 71A 100A 125ADimensions Unit HeightxWidthxDepth mm 198x950x950Weight Unit kg 25.0 26.0 25.0 26.0Air filter Type Resin netFan Air flow rate Cooling Low/Medium/High m³/min 16.0/19.5/23.0 20.0/25.5/31.0 20.5/26.5/32.5 16.0/19.5/23.0 20.0/25.5/31.0 20.5/26.5/32.5

Heating Low/Medium/High m³/min 16.0/19.5/23.0 20.0/25.5/31.0 20.5/26.5/32.5 16.0/19.5/23.0 20.0/25.5/31.0 20.5/26.5/32.5Sound power level Cooling dBA 59 64 65 59 64 65

Heating dBA 59 64 65 59 64 65Sound pressure level Cooling Low/High dBA 35/41 39/46 40/47 35/41 39/46 40/47

Heating Low/High dBA 35/41 39/46 40/47 35/41 39/46 40/47Power supply Phase/Frequency/Voltage Hz/V -/-/-

Outdoor unit RZAG 71MV1 100MV1 125MV1 71MY1 100MY1 125MY1Dimensions Unit HeightxWidthxDepth mm 990x940x320 1,430x940x320 990x940x320 1,430x940x320Weight Unit kg 70 92 70 92Sound power level Cooling dBA 64 66 69 65 66 69Sound pressure level Cooling Nom. dBA 46 47 50 46 47 50

Heating Nom. dBA 49 51 52 49 51 52Operation range Cooling Ambient Min.~Max. °CDB -20~52

Heating Ambient Min.~Max. °CWB -20~18.0Refrigerant Type/GWP R-32/675

Charge kg/TCO2Eq 2.95/1.99 3.75/2.53 2.95/1.99 3.75/2.53Piping connections Liquid/Gas mm 9,52/15.9

Piping length

OU - IU Max. m 55 85 55 85System Equivalent m 75 100 75 100

Chargeless m 40Additional refrigerant charge kg/m See installation manualLevel difference IU - OU Max. m 30.0

Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3~/50/380-415Current - 50Hz Maximum fuse amps (MFA) A 20 32 16

(1) EER/COP according to Eurovent 2012, for use outside EU only

(2) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

4-way blow ceiling suspended unit

Unique Daikin unit for high rooms with no false ceilings nor free floor space

ʯ Combination with Sky Air Alpha-series ensures best in class quality, highest efficiency and performance

ʯ Even rooms with ceilings up to 3.5m can be heated up or cooled down very easily without capacity loss

ʯ Can easily be installed in both new and refurbishment projects ʯ Unified indoor unit can be combined with R-32 and R-410A outdoor units, symplifying stock

ʯ Combining with R-32 Bluevolution technology, reduces environmental impact with 68% compared to R-410A, leads directly to lower energy consumption thanks to its high energy efficiency and has up to lower 16% refrigerant charge

ʯ Individual flap control: flexibility to suit every room layout without changing the location of the unit!

ʯ Stylish modern casing finished in pure white (RAL9010) and iron grey (RAL7011) blends easily with any interior

ʯ Optimum comfort guaranteed with automatic air flow adjustment to the required load

ʯ 5 different discharge angles between 0 and 60°can be programmed via the remote control

FUA-A + RZAG-MV1/RZAG-MY1UNIQUE

ʯ Standard drain pump with 500mm lift increases flexibility and installation speed

NEW Online controller connection

Page 51: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

51

UNIQUE

BRC1E52A-B, BRC7CB58RZASG100-140MV1_MY1

FUA-A

Efficiency data FUA + RZASG 71A + 71MV1 100A + 100MV1 125A + 125MV1 100A + 100MY1 125A + 125MY1Cooling capacity Nom. kW 6.80 9.50 12.1 9.50 12.1 Heating capacity Nom. kW 7.50 10.8 13.5 10.8 13.5 Seasonal efficiency (according to EN14825)

Cooling Energy efficiency class A++ A+ - A+ -Pdesign kW 6.80 9.50 12.1 9.50 12.1SEER 6.16 5.83 5.27 5.83 5.27Annual energy consumption kWh 386 570 1,378 570 1,378

Heating (Average climate)

Energy efficiency class A A+ - A+ -Pdesign kW 4.50 6.00SCOP/A 3.90 4.01 3.84 4.01 3.84Annual energy consumption kWh 1,615 2,095 2,188 2,095 2,188

Indoor unit FUA 71A 100A 125A 100A 125ADimensions Unit HeightxWidthxDepth mm 198x950x950Weight Unit kg 25.0 26.0Air filter Type Resin netFan Air flow rate Cooling Low/Medium/High m³/min 16.0/19.5/23.0 20.0/25.5/31.0 20.5/26.5/32.5 20.0/25.5/31.0 20.5/26.5/32.5

Heating Low/Medium/High m³/min 16.0/19.5/23.0 20.0/25.5/31.0 20.5/26.5/32.5 20.0/25.5/31.0 20.5/26.5/32.5Sound power level Cooling dBA 59 64 65 64 65

Heating dBA 59 64 65 64 65Sound pressure level Cooling Low/High dBA 35/41 39/46 40/47 39/46 40/47

Heating Low/High dBA 35/41 39/46 40/47 39/46 40/47Power supply Phase/Frequency/Voltage Hz/V -/-/-

Outdoor unit RZASG 71MV1 100MV1 125MV1 100MY1 125MY1Dimensions Unit HeightxWidthxDepth mm 770x900x320 990x940x320Weight Unit kg 60 70Sound power level Cooling dBA 65 70 71 70 71Sound pressure level Cooling Nom. dBA 46 53

Heating Nom. dBA 47 57Operation range Cooling Ambient Min.~Max. °CDB -15~46

Heating Ambient Min.~Max. °CWB -15~15.5Refrigerant Type/GWP R-32/675

Charge kg/TCO2Eq 2.45/1.65 2.60/1.76Piping connections Liquid/Gas mm 9,52/15.9

Piping length

OU - IU Max. m 50System Equivalent m 70

Chargeless m 30Additional refrigerant charge kg/m See installation manualLevel difference IU - OU Max. m 30.0

Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3~/50/380-415Current - 50Hz Maximum fuse amps (MFA) A 20 25 32 16

(1) EER/COP according to Eurovent 2012, for use outside EU only

(2) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

4-way blow ceiling suspended unit

Unique Daikin unit for high rooms with no false ceilings nor free floor space

ʯ Combination with Sky Air Advance-series ensures good value for money for all types of commercial applications

ʯ Even rooms with ceilings up to 3.5m can be heated up or cooled down very easily without capacity loss

ʯ Can easily be installed in both new and refurbishment projects ʯ Unified indoor unit can be combined with R-32 and R-410A outdoor units, symplifying stock

ʯ Combining with R-32 Bluevolution technology, reduces environmental impact with 68% compared to R-410A, leads directly to lower energy consumption thanks to its high energy efficiency and has up to lower 16% refrigerant charge

ʯ Individual flap control: flexibility to suit every room layout without changing the location of the unit!

ʯ Stylish modern casing finished in pure white (RAL9010) and iron grey (RAL7011) blends easily with any interior

FUA-A + RZASG-MV1/RZASG-MY1

NEW Online controller connection

Page 52: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

52

Efficiency data FVA + RZAG 71A + 71MV1

100A + 100MV1

125A + 125MV1

140A + 140MV1

71A + 71MY1

100A + 100MY1

125A + 125MY1

140A + 140MY1

Cooling capacity Nom. kW 6.80 9.50 12.1 13.4 6.80 9.50 12.1 13.4Heating capacity Nom. kW 7.50 10.8 13.5 15.5 7.50 10.8 13.5 15.5Seasonal efficiency (according to EN14825)

Cooling Energy efficiency class A++ A+ - A++ A+ -Pdesign kW 6,80 9,50 12,1 13,4 6,80 9,50 12,1 13,4SEER 6,37 6,00 6,41 6,12 6,37 6,00 6,41 6,12Annual energy consumption kWh 374 554 1133 1314 374 554 1133 1314

Heating (Average climate)

Energy efficiency class A+ - A+ -Pdesign kW 4,70 7,80 9,52 9,52 4,70 7,80 9,52 9,52SCOP/A 4,05 4,20 4,15 3,94 4,05 4,20 4,15 3,94Annual energy consumption kWh 1625 2600 3209 3383 1625 2600 3209 3383

Indoor unit FVA 71A 100A 125A 140A 71A 100A 125A 140ADimensions Unit HeightxWidthxDepth mm 1,850x600x270 1,850x600x350 1,850x600x270 1,850x600x350Weight Unit kg 39 47 39 47Air filter Type Resin net with mold resistanceFan - Air flow rate Cooling High/Low m³/min 18/14 28/22 28/24 30/26 18/14 28/22 28/24 30/26

Heating High/Low m³/min 18/14 28/22 28/24 30/26 18/14 28/22 28/24 30/26Sound power level Cooling dBA 55 62 63 65 55 62 63 65

Heating dBA 55 62 63 65 55 62 63 65Sound pressure level Cooling High/Low dBA 43/38 50/44 51/46 53/48 43/38 50/44 51/46 53/48

Heating High/Low dBA 43/38 50/44 51/46 53/48 43/38 50/44 51/46 53/48Refrigerant Type R-32 / R-410AControl systems Wired remote control BRC1D52 / BRC1E53A / BRC1E53B / BRC1E53CPower supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220

Outdoor unit RZAG 71MV1 100MV1 125MV1 140MV1 71MY1 100MY1 125MY1 140MY1Dimensions Unit HeightxWidthxDepth mm 990x940x320 1,430x940x320 990x940x320 1,430x940x320Weight Unit kg 70 92 78 70 92Sound power level Cooling dBA 64 66 69 73 65 66 69 70Sound pressure level Cooling Nom. dBA 46 47 50 54 46 47 50 51

Heating Nom. dBA 49 51 52 57 49 51 52Operation range Cooling Ambient Min.~Max. °CDB -20~52 -15~46 -20~52

Heating Ambient Min.~Max. °CWB -20~18.0 -15~15.5 -20~18.0Refrigerant Type/GWP R-32/675

Charge kg/TCO2Eq 2.95/1.99 3.75/2.53 2.90/1.96 2.95/1.99 3.75/2.53Piping connections Liquid/Gas mm 9,52/15.9

Piping length

OU - IU Max. m 55 85 50 55 85System Equivalent m 75 100 70 75 100

Chargeless m 40 30 40Additional refrigerant charge kg/m See installation manualLevel difference IU - OU Max. m 30.0

Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3~/50/380-415Current - 50Hz Maximum fuse amps (MFA) A 20 32 16

(1) EER/COP according to Eurovent 2012, for use outside EU only

(2) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

Floor standing unit

For commercial spaces with high ceilings

Combination with Sky Air Alpha-series ensures best in class quality, highest efficiency and performance

ʯ Unified range for R-32 and R-410A simplifying stock ʯ Ideal solution for commercial and busy environments ʯ Decrease of temperature variation by automatic fan speed selection or freely selectable 3-step fan speed.

ʯ Improved comfort as a result of better airflow distribution from the vertical out blow which allows manual adjustment of air outlet blades at the top of the unit.

ʯ Selectable horizontal out blow to better suit the layout of the room (via wired remote controller BRC1E52)

ʯ No optional adapter needed for DIII-connection, link your unit into the wider building management system.

FVA-A + RZAG-MV1/MY1

Up

Side view blades air outlet

All up

All down Down

BRC1E53A-B-C

FVA71A

NEW Online controller connection

RZAG100-140MV1_MY1

Page 53: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

53

Floor standing unit

For commercial spaces with high ceilings

Combination with Sky Air Alpha-series ensures best in class quality, highest efficiency and performance

ʯ Unified range for R-32 and R-410A simplifying stock ʯ Ideal solution for commercial and busy environments ʯ Decrease of temperature variation by automatic fan speed selection or freely selectable 3-step fan speed.

ʯ Improved comfort as a result of better airflow distribution from the vertical out blow which allows manual adjustment of air outlet blades at the top of the unit.

ʯ Selectable horizontal out blow to better suit the layout of the room (via wired remote controller BRC1E52)

ʯ No optional adapter needed for DIII-connection, link your unit into the wider building management system.

Up

Side view blades air outlet

All up

All down Down

BRC1E53A-B-C

FVA71A

Efficiency data FVA + RZASG 71A + 71MV1

100A + 100MV1

125A + 125MV1

140A + 140MV1

100A + 100MY1

125A + 125MY1

140A + 140MY1

Cooling capacity Nom. kW 6.80 9.50 12.1 13.4 9.50 12.1 13.4Heating capacity Nom. kW 7.50 10.8 13.5 15.5 10.8 13.5 15.5Power input Cooling Nom. kW - - - - - - -

Heating Nom. kW - - - - - - -Seasonal efficiency (according to EN14825)

Cooling Energy efficiency class A+ - A+ -

Pdesign kW 6,80 9,50 12,1 13,4 9,50 12,1 13,4SEER 5,83 5,72 5,30 5,63 5,72 5,30 5,63Annual energy consumption kWh 408 581 1370 1428 581 1370 1428

Heating (Average climate)

Energy efficiency class A+ A - A -Pdesign kW 4,50 6,00 6,00 7,80 6,00 6,00 7,80SCOP/A 4,04 3,83 3,64 3,81 3,83 3,64 3,81Annual energy consumption kWh 4,04 3,83 3,64 3,81 3,83 3,64 3,81

Nominal efficiency EER 3.21 3.37 2.81 3.16 3.37 2.81 3.16COP 3.69 3.65 3.47 3.41 3.65 3.47 3.41

Annual energy consumption kWh 1559 2193 2308 2866 2193 2308 2866Energy labeling Directive Cooling/Heating - - - - - - -

Indoor unit FVA 71A 100A 125A 140A 100A 125A 140ADimensions Unit HeightxWidthxDepth mm 1,850x600x270 1,850x600x350Weight Unit kg 39 47Air filter Type Resin net with mold resistanceFan - Air flow rate Cooling High/Low m³/min 18/14 28/22 28/24 30/26 28/22 28/24 30/26

Heating High/Low m³/min 18/14 28/22 28/24 30/26 28/22 28/24 30/26Sound power level Cooling dBA 55 62 63 65 62 63 65

Heating dBA 55 62 63 65 62 63 65Sound pressure level Cooling High/Low dBA 43/38 50/44 51/46 53/48 50/44 51/46 53/48

Heating High/Low dBA 43/38 50/44 51/46 53/48 50/44 51/46 53/48Refrigerant Type R-32 / R-410AControl systems Wired remote control BRC1D52 / BRC1E53A / BRC1E53B /BRC1E53ACPower supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220

Outdoor unit RZASG 71MV1 100MV1 125MV1 140MV1 100MY1 125MY1 140MY1Dimensions Unit HeightxWidthxDepth mm 770x900x320 990x940x320Weight Unit kg 60 70 78 70 77Sound power level Cooling dBA 65 70 71 73 70 71 73Sound pressure level Cooling Nom. dBA 46 53 54 53 54

Heating Nom. dBA 47 57Operation range Cooling Ambient Min.~Max. °CDB -15~46

Heating Ambient Min.~Max. °CWB -15~15.5Refrigerant Type/GWP R-32/675

Charge kg/TCO2Eq 2.45/1.65 2.60/1.76 2.90/1.96 2.60/1.76 2.90/1.96Piping connections Liquid/Gas mm 9,52/15.9

Piping length

OU - IU Max. m 50System Equivalent m 70

Chargeless m 30Additional refrigerant charge kg/m See installation manualLevel difference IU - OU Max. m 30.0

Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3~/50/380-415Current - 50Hz Maximum fuse amps (MFA) A 20 25 32 16 20 16

(1) EER/COP according to Eurovent 2012, for use outside EU only

(2) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

FVA-A + RZASG-MV1/MY1

RZASG100-140MV1_MY1

NEW Online controller connection

Page 54: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared
Page 55: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

55

BRC1E53A-B-CRXM35M9

FNQ-A

Concealed floor standing unit

Designed to be concealed in walls

Combination with split outdoor units is ideal for small retail, offices or residential applications

ʯ Unified range for R-32 and R-410A simplifying stock ʯ Ideal for installation in offices, hotels and residential applications

ʯ Blends unobtrusively with any interior design: only the suction and discharge grills are visible

ʯ Its low height (620 mm) enables the unit to fit perfectly beneath a window

ʯ Requires very little installation space as the depth is only 200mm

ʯ High ESP allows flexible installation

FNA-A + RXM-M9

BRC4C65

Efficiency data FNA + RXM 25A + 25M9 35A + 35M9 50A + 50M9 60A + 60M9Cooling capacity Nom. kW 2,60 3,40 5,00 6,00Heating capacity Nom. kW 3,20 4,00 5,80 7,00Power input Cooling Nom. kW 0,68 1,10 1,48 2,22

Heating Nom. kW 0,80 1,15 1,74 2,25Seasonal efficiency (according to EN14825)

Cooling Energy efficiency class A+ APdesign kW 2,60 3,40 5,00 6,00SEER 5,68 5,70 5,77 5,56Annual energy consumption kWh 160 209 303 378

Heating (Average climate)

Energy efficiency class A+Pdesign kW 2,80 2,90 4,00 4,60SCOP/A 4,24 4,05 4,09 4,16Annual energy consumption kWh 924 1002 1369 1547

Nominal efficiency EER 3.80 3.09 3.38 2.70COP 4.00 3.48 3.34 3.11Annual energy consumption kWh - - - -Energy labeling Directive Cooling/Heating - - - -

Indoor unit FNA 25A 35A 50A 60ADimensions Unit HeightxWidthxDepth mm 620 / 720(2)x750x200 620 / 720(2)x1,150x200Weight Unit kg 23 30Air filter Type Resin net with mold resistanceFan - Air flow rate Cooling High/Low m³/min 8.7/7.3 16.0/13.5

Heating High/Low m³/min 8.7/7.3 16.0/13.5Fan - External static pressure High/Nom./Maximum available/High Pa 48/30/- 49/40/-Sound power level Cooling dBA 53 56Sound pressure level Cooling High/Low dBA 33/28 36/30

Heating High/Low dBA 33/28 36/30Refrigerant Type R-32 / R-410AControl systems Infrared remote control BRC4C65

Wired remote control BRC1D52 / BRC1E53A / BRC1E53B / BRC1E53CPower supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220

Outdoor unit RXM 25M9 35M9 50M9 60M9Dimensions Unit HeightxWidthxDepth mm 550x765x285 735x825x300Weight Unit kg 32 47Sound power level Cooling dBA 59 61 62 63

Heating dBA 59 61 62 63Sound pressure level Cooling Low/High dBA 46/- 49/- 48/44

Heating Low/High dBA 47/- 49/- 49/45Operation range Cooling Ambient Min.~Max. °CDB -10~46

Heating Ambient Min.~Max. °CWB -15~18Refrigerant Type R-32

GWP 675.0Charge kg/TCO2Eq 0.76/0.52 1.40/0.95 1.45/0.98

Piping connections Liquid OD mm 6,35 6,4Gas OD mm 9.50 12.7Piping length

OU - IU Max. m 20.0 30System Chargeless m 10.0 -

Additional refrigerant charge kg/m 0.02 (for piping length exceeding 10m)Level difference IU - OU Max. m 20.0

Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240Current - 50Hz Maximum fuse amps (MFA) A 10 15

(1) EER/COP according to Eurovent 2012, for use outside EU only

(2) Including installation legs (3) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). For more detailed information on each combination, please refer to the electrical data drawing.

Split

NEW Online controller connection

Page 56: Our mission Achieve the lowest environmental impact...Low environmental impact, R-32 refrigerant GWP is 68% lower than R-410A Equipped with tested and trusted Daikin technology 4 Geared

The future is in your handsDefine the future of A/C

Introducing the new Sky Air A-series with ultra-efficient Bluevolution R32 technology, available in three models: the world-class Alpha, Advance and Active.

The new Sky Air with R32 delivers future-proofed, best-in-class climate control for your business and customers.

Design flexibility. More compact. Quieter. With an extended operating range in all climate conditions.

Help is at hand. Quicker and easier installation and usability, even for replacement systems.

Daikin at the heart of the system. Exceptionally low running costs. Even lower environmental impact. All thanks to Daikin’s tried, tested and trusted technology.

Geared for comfort. Optimal remote control, geared to your customers’ individual needs.

R32 is an industry revolution. Be part of it.

Get ahead of the competition. Talk to Daikin about Sky Air today.www.daikin.eu/skyairbluevolution

The present publication is drawn up by way of information only and does not constitute an offer binding upon

Daikin Europe N.V. Daikin Europe N.V. has compiled the content of this publication to the best of its knowledge. No

express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its

content and the products and services presented therein. Specifications are subject to change without prior notice.

Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from

or related to the use and/or interpretation of this publication. All content is copyrighted by Daikin Europe N.V.

The present publication supersedes ECPEN17-116. Printed on non-chlorinated paper.

Daikin Europe N.V. Naamloze Vennootschap Zandvoordestraat 300 · 8400 Oostende · Belgium · www.daikin.eu · BE 0412 120 336 · RPR Oostende (Responsible Editor)

ECPEN17 - 116A 08/17

FSCDaikin Europe N.V. participates in the Eurovent Certified

Performance programme for Liquid Chilling Packages and

Hydronic Heat Pumps, Fan Coil Units and Variable Refrigerant

Flow systems. Check ongoing validity of certificate:

www.eurovent-certification.com