RCR11 FEATURES RCR11 is part of the ProAir™ Series which combines state-of-the-art design with pleasing aesthetics. This rack mount model is an excellent, high-efficiency model with a patented airflow system that allows it to be mounted anywhere within the enclosure. RCR11 stock models have thermostat control and EMI/RFI noise suppressor. Rack mount models are ideal when it is important to keep an application self-contained within the enclosure. Unique condensate management system evaporates moisture from enclosure to ambient air eliminating drain tubes, buckets and wet floors. High CFM blowers are used for maximum airflow throughout enclosure. 100% functionally tested. Mounting gaskets, drawings and instruction manual furnished. All units use a CFC-free or environmentally safe refrigerant that is universally accepted. Some LB16 Series and LB14 Series models available with UL listing at additional cost. (UL File SA6453) Please contact the factory. NEMA 12 per UL 50 Type 12 approval on all models. OPTIONS (SEE PGS. 80-81) RCR11 LB14 LB16 Thermostat Package Thermostat/Malfunction Package Special Voltage Package Corrosive Environment Package Stainless Steel Package Heater Package N/A RACK-MOUNT Air Conditioners 2000-10000 BTU/HR. 586-2930 WATTS McLEAN MIDWEST CLOSED-LOOP COOLING Within the air conditioner, the recirculated clean enclosure air is kept separate from the ambient airflow system. This protects the electronic controls and prevents shutdowns caused by heat, humidity, dust and other contaminants. LB16 LB14 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz

Upload: dangxuyen

Post on 29-Nov-2018

216 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union ... · • Mounting gaskets, drawings and instruction manual furnished. •All units use a CFC-free or environmentally safe

RCR11

FEATURES

• RCR11 is part of the ProAir™ Series which combines state-of-the-art design

with pleasing aesthetics. This rack mount model is an excellent, high-efficiency

model with a patented airflow system that allows it to be mounted anywhere

within the enclosure. RCR11 stock models have thermostat control and EMI/RFI

noise suppressor.

• Rack mount models are ideal when it is important to keep an application

self-contained within the enclosure.

• Unique condensate management system evaporates moisture from enclosure to

ambient air eliminating drain tubes, buckets and wet floors.

• High CFM blowers are used for maximum airflow throughout enclosure.

• 100% functionally tested.

• Mounting gaskets, drawings and instruction manual furnished.

• All units use a CFC-free or environmentally safe refrigerant that is

universally accepted.

Some LB16 Series and LB14 Series models available with UL listing at additional

cost. (UL File SA6453) Please contact the factory. NEMA 12 per UL 50 Type 12

approval on all models.

OPTIONS (SEE PGS. 80-81)

RCR11 LB14 LB16

Thermostat Package ✔ ✔ ✔

Thermostat/Malfunction Package ✔ ✔ ✔

Special Voltage Package ✔ ✔ ✔

Corrosive Environment Package ✔ ✔ ✔

Stainless Steel Package ✔ ✔ ✔

Heater Package ✔ ✔ N/A

RACK-MOUNT Air Conditioners 2000-10000 BTU/HR.586-2930 WATTS

McLEAN MIDWEST CLOSED-LOOP COOLING

Within the air conditioner, the recirculated clean enclosure air is kept separate

from the ambient airflow system. This protects the electronic controls and

prevents shutdowns caused by heat, humidity, dust and other contaminants.

LB16 LB14

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz

Page 2: Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union ... · • Mounting gaskets, drawings and instruction manual furnished. •All units use a CFC-free or environmentally safe

FEATURES

• Water-Cooled air conditioners are for especially hostile, dirty environments or

where temperatures exceed 125°F/52°C. Varied sizes, capacities and mounting

options provide a wide range of choice.

• 33WC and 47WC Series are side-mount models, and the LB11WC is a rack

mount unit.

• 33WC will mount to 12" deep enclosure.

• Operate quietly, consume low power, no condenser blower or filter to clean, and

have an extra-long operating life.

• Add no heat to surroundings and require no fresh air ducting.

• Water regulating valve and water interruption shut-down switch is standard.

• 100% functionally tested.

• Mounting gaskets, drawings and instruction manual furnished.

• All units use a CFC-free or environmentally safe refrigerant that is

universally accepted.

NEMA 12 per UL 50 Type 12 approval on all models.

OTHER UNITS TO CONSIDER

33 Water-Cooled: Genesis™ 33NSM, pg. 32

47 Water-Cooled: 47N Series, pg. 32

OPTIONS (SEE PGS. 80-81)

33WC 47WC LB11WC

Thermostat Package ✔ ✔ ✔

Thermostat/Malfunction Package ✔ ✔ ✔

Condensate Evaporator Package ✔ ✔ N/A

Special Voltage Package ✔ ✔ ✔

Corrosive Environment Package* ✔ ✔ ✔

Stainless Steel Package* ✔ ✔ ✔

Heater Package ✔ ✔ ✔

* Please refer to pgs. 36-39 for our air conditioners that have been engineered and manufacturedspecifically for demanding applications.

4000-12000 BTU/HR.1172-3516 WATTS

LB11WC33WC

47WC

WATER-COOLED Air Conditioners

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz

Page 3: Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union ... · • Mounting gaskets, drawings and instruction manual furnished. •All units use a CFC-free or environmentally safe

33WC Series4000 BTU/Hr. (1172 Watts) H x W x D: 34.13" (867) x 12.38" (314) x 8.75" (222)

Full BTU/Hr @ Max °F/°C Max Water Shipping

Load 125°F Enclosure Water Usage Weight

Model Voltage Hz Amps Phase Air Temp Temp (GPM)* Lbs/Kgs

33-0416-GW0XX 115 50/60 6.0/5.8 1 3800/4000 90/32 0.5 86/39

33-0426-GW0XX 230 50/60 3.3/3.2 1 3800/4000 90/32 0.5 86/39

-XX will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers.*Rated at 90°F inlet water and full air conditioning load. Actual usage will vary.

LB11WC Series4000 BTU/Hr. (1172 Watts) H x W x D: 10.47" (266) x 19" (483) x 19.63" (499)

Full BTU/Hr @ Max °F/°C Max Water Shipping

Load 125°F Enclosure Water Usage Weight

Model Voltage Hz Amps Phase Air Temp Temp (GPM)* Lbs/Kgs

LB11-0416-GW0XX 115 50/60 9.0 1 3300/4000 90/38 1.0 105/48

LB11-0426-GW0XX 230 50/60 4.5 1 3300/4000 90/38 1.0 100/45

-XX will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers.*Rated at 90°F inlet water and full air conditioning load. Actual usage will vary.

47WC Series8000-12000 BTU/Hr. (2344-3516 Watts) H x W x D: 47.25" (1200) x 19" (483) x 10" (254)

Full BTU/Hr @ Max °F/°C Max Water Shipping

Load 125°F Enclosure Water Usage Weight

Model Voltage Hz Amps Phase Air Temp Temp (GPM)* Lbs/Kgs

47-0815-W0XX 115 50/60 10.0 1 6600/8000 90/32 2.0 160/73

47-0816-W0XX 115 60 10.0 1 8000 90/32 2.0 155/70

47-0825-W0XX 230 50 5.5 1 8000 90/32 2.0 155/70

47-0826-W0XX 230 60 5.0 1 8000 90/32 2.0 155/70

47-1215-W0XX 115 50/60 14.0 1 10000/12000 90/32 2.0 160/73

47-1216-W0XX 115 60 14.0 1 12000 90/32 2.0 155/70

47-1225-W0XX 230 50 7.0 1 12000 90/32 2.0 155/70

47-1226-W0XX 230 60 7.0 1 12000 90/32 2.0 155/70

-XX will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers.*Rated at 90°F inlet water and full air conditioning load. Actual usage will vary.Most models available with Hz selector switch, if desired. Contact factory.The 50/60 Hz units, because of the addition of an autotransformer, cost more that straight 60 Hz models. Units wired for 50 Hz operation when shipped. Asingle internal wiring change is required for 60 Hz operation.

WA

TE

R-C

OO

LE

D

McLEAN MIDWEST CLOSED-LOOP COOLING

Within the air conditioner, the recirculated clean enclosure air is kept

separate from the ambient airflow system. This protects the electronic

controls and prevents shutdowns caused by heat, humidity, dust and

other contaminants.

AIR

CO

ND

ITIO

NE

RS

33W

C,

47W

C,

LB

11W

C❑ Clean air flow

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz

Page 4: Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union ... · • Mounting gaskets, drawings and instruction manual furnished. •All units use a CFC-free or environmentally safe

CUT-OUT NOTES

1. Cord is routed

through the 2" x 11.13"

return air opening (top).

2. Dash lines

represent air

conditioner.

▲3. Bottom opening

will accommodate air

conditioner or heat

exchanger.

4. Cut-out dimensions

for standard product

only.33W

C S

ER

IES

47W

C S

ER

IES

LB

11W

C S

ER

IES

CUT-OUT NOTES

▲1. This cord hole may

be deleted if the service

cord is routed through

the 3" x 16.75" return

air opening.

2. Dash lines

represent air

conditioner.

▲3. This cut-out

accommodates units to

12000 BTU/Hr.

4. Cut-out dimensions

for standard product

only.

CUT-OUT NOTES

1. Dash lines represent

air conditioner.

2. Entire weight of air

conditioner is not

intended to be supported

by the mounting flanges.

Slide rails should be

installed.

3. Cut-out dimensions

for standard product

only.

SIDE MOUNT TO ENCLOSURE

For NEMA type 12 enclosure, interfacing air-out and

air-in openings are required in the enclosure wall.

SIDE MOUNT TO ENCLOSURE

For NEMA type 12 enclosure, interfacing air-out and

air-in openings are required in the enclosure wall.

RACK MOUNT TO ENCLOSURE

Unit may be rack mounted near the bottom of the

enclosure as shown, or use cut-out drawing for

NEMA type 12 enclosures.

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz

Page 5: Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union ... · • Mounting gaskets, drawings and instruction manual furnished. •All units use a CFC-free or environmentally safe

DESIGN NOTES

1. Gasket kit for

mounting to enclosure

included.

2. Service cord

terminated with

appropriate plug cap.

3. Condensate drain

hose included.

DESIGN NOTES

1. Gasket kit formounting to enclosureincluded.

2. Service cordterminated withappropriate plug cap.

3. Condensate drainhose included.

▲4. This 37.06" x 16.75"area is recessed 1.44"from rear surface(referred to as the “plenum”).

▲5. Cool air outletdimensions for 8000-12000 BTU/Hr units.

DESIGN NOTES

1. Gasket kit for

mounting to enclosure

included.

2. Service cord

terminated with

appropriate plug cap.

3. Condensate drain

hose included.

AIR

CO

ND

ITIO

NE

RS

33W

C,

47W

C,

LB

11W

CW

AT

ER

-CO

OL

ED

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz

Page 6: Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union ... · • Mounting gaskets, drawings and instruction manual furnished. •All units use a CFC-free or environmentally safe

FEATURES

• Stock models include thermostat control and EMI/RFI noise suppressor.

UL/CUL listing is standard on CR23, CR29 and CR43 stock models.

• The ProAir™ Series combines state-of-the-art design with pleasing aesthetics. This

highly efficient series offers a broad range of sizes and performance capacities.

• For more sophisticated requirements we offer Levels II and III Smart Control.

This microprocessor-based option provides programmable temperature

management, digital display of enclosure temperature, as well as remote

alarm capabilities.

• Maintenance is made easy by front cover hinging open for quick access to

all components.

• The Flip Filter design on the CR23 and CR29 uses only 50% of the filter surface

so filter can be inverted to double operating time between

cleanings/replacements.

• EZ Mount flanges simplify installation to a two-step, one-person job.

• Filterless operation possible in many applications.

• Unique condensate management system evaporates moisture from enclosure and

eliminates drain tubes, buckets and wet floors.

• High performance fans and blowers are ideal for densely packed enclosures.

• 100% functionally tested.

• Mounting hardware, gaskets, drawings, mounting template and instruction

manual furnished.

• All units use a CFC-free or environmentally safe refrigerant that is

universally accepted.

Most models available with UL and CUL listing. (UL File SA6453) CE available

upon request. Please contact the factory. NEMA 12 per UL 50 type 12 approval

on all models.

OTHER UNITS TO CONSIDER

CR23: CR23 Stainless Steel, pg. 36; Genesis™ 17, pg. 20

CR29: CR29 Stainless Steel, pg. 36; Genesis™ 28, pg. 24

CR43: CR43 Stainless Steel pg. 36

OPTIONS (SEE PGS. 80-81)

CR23 CR29 CR43

Smart Control Package ✔ ✔ ✔

Thermostat Package ✔ ✔ ✔

Thermostat/Malfunction Package ✔ ✔ ✔

Special Voltage Package ✔ ✔ ✔

Outdoor Package* ✔ ✔ ✔

Corrosive Environment Package* ✔ ✔ ✔

Stainless Steel Package SEE PAGES 36-39

Heater Package ✔ ✔ ✔

* Please refer to pgs. 36-39 for our air conditioners that have been engineered and manufacturedspecifically for demanding applications.

COMPACT TO FULL-SIZE Air Conditioners 1600-8500 BTU/HR.469-2490 WATTS

TM

CR43

CR29

CR23

The Ultimate Line

McLEAN MIDWEST CLOSED-LOOP COOLING

Within the air conditioner, the recirculated clean enclosure air is kept separate

from the ambient airflow system. This protects the electronic controls and

prevents shutdowns caused by heat, humidity, dust and other contaminants.

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz

Page 7: Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union ... · • Mounting gaskets, drawings and instruction manual furnished. •All units use a CFC-free or environmentally safe

CR231600 BTU/Hr. (469 Watts) H x W x D: 23" (584) x 10" (254) x 8.75" (222)

Max Shipping

BTU/Hr @ Amps @ BTU/Hr @ Amps @ Amb Temp Weight

Model Voltage Hz Phase 131°F/131°F* 131°F/131°F 95°F/95°F* 95°F/95°F °F/°C Lbs/Kgs

CR23-0216-G002 STOCK 115 50/60 1 1400/1600 4.1/4.5 1500/1700 3.8/3.6 131/55 57/26

CR23-0216-G0XX 115 50/60 1 1400/1600 4.1/4.5 1500/1700 3.8/3.6 131/55 57/26

CR23-0226-G002 STOCK 230 50/60 1 1400/1600 2.2/2.2 1500/1700 2.1/1.8 131/55 57/26

CR23-0226-G0XX 230 50/60 1 1400/1600 2.2/2.2 1500/1700 2.1/1.8 131/55 57/26

-XX will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers.*Two cooling capacities are listed to demonstrate the consistent performance throughout the typical operating range.

CR292000-4000 BTU/Hr. (586-1172 Watts) H x W x D: 29.50" (749) x 15.75" (400) x 8.63" (219)

Max Shipping

BTU/Hr @ Amps @ BTU/Hr @ Amps @ Amb Temp Weight

Model Voltage Hz Phase 131°F/131°F* 131°F/131°F 95°F/95°F* 95°F/95°F °F/°C Lbs/Kgs

CR29-0216-G002 STOCK 115 50/60 1 2000/2200 7.4/7.4 1700/2000 7.0/6.0 131/55 98/44

CR29-0216-G0XX 115 50/60 1 2000/2200 7.4/7.4 1700/2000 7.0/6.0 131/55 98/44

CR29-0226-G002 STOCK 230 50/60 1 2500/2700 4.6/3.9 1900/2300 4.4/3.3 131/55 98/44

CR29-0226-G0XX 230 50/60 1 2500/2700 4.6/3.9 1900/2300 4.4/3.3 131/55 98/44

CR29-0416-G002 STOCK 115 50/60 1 3500/4000 13.5/13.5 2400/2800 10.7/9.6 131/55 118/54

CR29-0416-G0XX 115 50/60 1 3500/4000 13.5/13.5 2400/2800 10.7/9.6 131/55 118/54

CR29-0426-G002 STOCK 230 50/60 1 3500/4000 6.7/6.6 2400/2800 5.9/5.3 131/55 118/54

CR29-0426-G0XX 230 50/60 1 3500/4000 6.7/6.6 2400/2800 5.9/5.3 131/55 118/54

-XX will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers.*Because air conditioners provide less cooling at lower operating temperatures, two cooling capacity ratings are listed for each ProAir™ air conditioner toassist you in your selection.

CR436000-8500 BTU/Hr. (1758-2490 Watts) H x W x D: 43.31" (1100) x 15.75" (400) x 10.25" (260)

Max Shipping

BTU/Hr @ Amps @ BTU/Hr @ Amps @ Amb Temp Weight

Model Voltage Hz Phase 131°F/131°F* 131°F/131°F 95°F/95°F* 95°F/95°F °F/°C Lbs/Kgs

CR43-0616-002 STOCK 115 60 1 6000 13.7 5100 11.0 131/55 133/60

CR43-0615-0XX 115 50/60 1 5800/6000 14.6/13.7 4800/5100 12.5/11.0 131/55 131/59

CR43-0616-0XX 115 60 1 6000 13.7 5100 11.0 131/55 131/59

CR43-0625-0XX 230 50 1 6000 6.8 5100 5.3 131/55 131/59

CR43-0626-002 STOCK 230 60 1 6000 6.9 5100 5.5 131/55 131/59

CR43-0626-0XX 230 60 1 6000 6.9 5100 5.5 131/55 131/59

CR43-0816-002 STOCK 115 60 1 8500 16.0 7500 12.9 131/55 140/64

CR43-0815-0XX 115 50/60 1 7500/8500 15.0/16.0 6700/7500 13.5/12.9 131/55 138/63

CR43-0816-0XX 115 60 1 8500 16.0 7500 12.9 131/55 138/63

CR43-0825-0XX 230 50 1 7500 8.0 7000 6.1 131/55 138/63

CR43-0826-002 STOCK 230 60 1 8500 8.2 7500 6.3 131/55 138/63

CR43-0826-0XX 230 60 1 8500 8.2 7500 6.3 131/55 138/63

-XX will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers.*Because air conditioners provide less cooling at lower operating temperatures, two cooling capacity ratings are listed for each ProAir™ air conditioner toassist you in your selection.

AIR

CO

ND

ITIO

NE

RS

CR

23,

CR

29,

CR

43

CR43

TM

TM

TM

TMCR29

CR23

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz

Page 8: Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union ... · • Mounting gaskets, drawings and instruction manual furnished. •All units use a CFC-free or environmentally safe

CUT-OUT NOTES

1. Dash lines represent

air conditioner.

2. Cut-out dimensions

for standard product

only.

3. Full-size mounting

template provided.

CR

23C

R29

CR

43

CUT-OUT NOTES

1. Dash lines represent

air conditioner.

2. Cut-out dimensions

for standard product

only.

3. Full-size mounting

template provided.

CUT-OUT NOTES

1. Dash lines represent

air conditioner.

2. Cut-out dimensions

for standard product

only.

3. Full-size mounting

template provided.

SIDE MOUNT TO ENCLOSURE

For NEMA type 12 enclosure, interfacing air-out and

air-in openings are required in the enclosure wall.

SIDE MOUNT TO ENCLOSURE

For NEMA type 12 enclosure, interfacing air-out and

air-in openings are required in the enclosure wall.

SIDE MOUNT TO ENCLOSURE

For NEMA type 12 enclosure, interfacing air-out and

air-in openings are required in the enclosure wall.

TMTM

TMOrder from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz

Page 9: Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union ... · • Mounting gaskets, drawings and instruction manual furnished. •All units use a CFC-free or environmentally safe

DESIGN NOTES

1. Gasket kit for

mounting to enclosure

included.

▲2. Service cord

terminated with

appropriate plug cap.

DESIGN NOTES

1. Gasket kit for

mounting to enclosure

included.

▲2. Service cord

terminated with

appropriate plug cap.

DESIGN NOTES

1. Gasket kit for

mounting to enclosure

included.

▲2. Service cord

terminated with

appropriate plug cap.

AIR

CO

ND

ITIO

NE

RS

CR

23,

CR

29,

CR

43

TM

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz

Page 10: Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union ... · • Mounting gaskets, drawings and instruction manual furnished. •All units use a CFC-free or environmentally safe

FEATURES

• Constructed of high-grade 16-gauge type 304 stainless steel for increased

protection in corrosive and outdoor applications.

• The Corrosive Environment and Outdoor Option Packages can be ordered

separately or together to provide optimum defense against especially harsh

conditions. The Corrosive Environment Package protects components exposed to

the corrosive environment on the ambient side of the air conditioner. The

Outdoor Package includes low temperature controls for operating down to -40°F.

• The ProAir™ Series combines state-of-the-art design with pleasing aesthetics. This

highly efficient series offers a broad range of sizes and performance capacities.

• For more sophisticated requirements we offer Levels II and III Smart Control. This

microprocessor-based option provides programmable temperature management,

digital display of enclosure temperature, as well as remote alarm capabilities.

• Maintenance is made easy by front cover hinging open for quick access to

all components.

• The Flip Filter design on the CR23 and CR29 uses only 50% of the filter surface so

filter can be inverted to double operating time between cleanings/replacements.

• EZ Mount flanges simplify installation to a two-step, one-person job.

• Filterless operation possible in many applications.

• Unique condensate management system evaporates moisture from enclosure and

eliminates drain tubes, buckets and wet floors.

• High performance fans and blowers are ideal for densely packed enclosures.

• 100% functionally tested.

• Mounting hardware, gaskets, drawings, mounting template and instruction

manual furnished.

• All units use a CFC-free or environmentally safe refrigerant that is

universally accepted.

Most models available with UL and CUL listing. CE available upon request.

Please contact the factory. (UL File SA6453) NEMA 12 per UL 50 Type 12 approval

on all models. NEMA 4X per UL 50 Type 4X optional.

OTHER UNITS TO CONSIDER

CR23 Stainless Steel: CR23, pg. 16; Genesis™ 17, pg. 20

CR29 Stainless Steel: CR29, pg. 16; Genesis™ 28, pg. 24

CR43 Stainless Steel: CR43, pg. 16

OPTIONS (SEE PGS. 80-81)

CR23 CR29 CR43

Smart Control Package ✔ ✔ ✔

Thermostat Package ✔ ✔ ✔

Thermostat/Malfunction Package ✔ ✔ ✔

Special Voltage Package ✔ ✔ ✔

Outdoor Package* ✔ ✔ ✔

Corrosive Environment Package* ✔ ✔ ✔

Heater Package ✔ ✔ ✔NEMA 4X Package (see note on pg. 37) ✔ ✔ ✔

* Must be ordered separately to achieve desired protection.

OUTDOOR/CORROSIVE/STAINLESS STEEL 1600-8500 BTU/HR.469-2490 WATTS

TM

CR43CR29 CR23

The Ultimate Protection

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz

Page 11: Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union ... · • Mounting gaskets, drawings and instruction manual furnished. •All units use a CFC-free or environmentally safe

CR43

TM

TM TM

Stainless Steel CR231600 BTU/Hr. (469 Watts) H x W x D: 23" (584) x 10" (254) x 8.75" (222)

Max Shipping

BTU/Hr @ Amps @ BTU/Hr @ Amps @ Amb Temp Weight

Model Voltage Hz Phase 131°F/131°F* 131°F/131°F 95°F/95°F* 95°F/95°F °F/°C Lbs/Kgs

CR23-0216-G0ST 115 50/60 1 1400/1600 4.1/4.5 1500/1700 3.8/3.6 131/55 57/26

CR23-0226-G0ST 230 50/60 1 1400/1600 2.2/2.2 1500/1700 2.1/1.8 131/55 57/26

-0ST will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers.* Two cooling capacities are listed to demonstrate the consistent performance throughout the typical operating range.

Stainless Steel CR292000-4000 BTU/Hr. (586-1172 Watts) H x W x D: 29.50" (749) x 15.75" (400) x 8.63" (219)

Max Shipping

BTU/Hr @ Amps @ BTU/Hr @ Amps @ Amb Temp Weight

Model Voltage Hz Phase 131°F/131°F* 131°F/131°F 95°F/95°F* 95°F/95°F °F/°C Lbs/Kgs

CR29-0216-G0ST 115 50/60 1 2000/2200 7.4/7.4 1700/2000 7.0/6.0 131/55 98/44

CR29-0226-G0ST 230 50/60 1 2500/2700 4.6/3.9 1900/2300 4.4/3.3 131/55 98/44

CR29-0416-G0ST 115 50/60 1 3500/4000 13.5/13.5 2400/2800 10.7/9.6 131/55 118/54

CR29-0426-G0ST 230 50/60 1 3500/4000 6.7/6.6 2400/2800 5.9/5.3 131/55 118/54

-0ST will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers.*Because air conditioners provide less cooling at lower operating temperatures, two cooling capacity ratings are listed for each ProAir™ air conditioner toassist you in your selection.

Stainless Steel CR436000-8500 BTU/Hr. (1758-2490 Watts) H x W x D: 43.31" (1100) x 15.75" (400) x 10.25" (260)

Max Shipping

BTU/Hr @ Amps @ BTU/Hr @ Amps @ Amb Temp Weight

Model Voltage Hz Phase 131°F/131°F* 131°F/131°F 95°F/95°F* 95°F/95°F °F/°C Lbs/Kgs

CR43-0615-0ST 115 50/60 1 5800/6000 14.6/13.7 4800/5100 12.5/11.0 131/55 131/59

CR43-0616-0ST 115 60 1 6000 13.7 5100 11.0 131/55 131/59

CR43-0625-0ST 230 50 1 6000 6.8 5100 5.3 131/55 131/59

CR43-0626-0ST 230 60 1 6000 6.9 5100 5.5 131/55 131/59

CR43-0815-0ST 115 50/60 1 7500/8500 15.0/16.0 6700/7500 13.5/12.9 131/55 138/63

CR43-0816-0ST 115 60 1 8500 16.0 7500 12.9 131/55 138/63

CR43-0825-0ST 230 50 1 7500 8.0 7000 6.1 131/55 138/63

CR43-0826-0ST 230 60 1 8500 8.2 7500 6.3 131/55 138/63

-0ST will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers.*Because air conditioners provide less cooling at lower operating temperatures, two cooling capacity ratings are listed for each ProAir™ air conditioner toassist you in your selection.

McLEAN MIDWEST CLOSED-LOOP COOLING

Within the air conditioner, the recirculated clean enclosure air is kept separate

from the ambient airflow system. This protects the electronic controls and

prevents shutdowns caused by heat, humidity, dust and other contaminants.

OU

TD

OO

R/C

ORR

OSI

VE/

STA

INLE

SS S

TEE

LC

R23,

CR

29,

CR

43

TM

TM

TM

NEMA 4X

The protective shields illustrated

here are required to achieve NEMA

4X. Shield protrudes approximately

2" from the air conditioner. Contact

factory for details.

CR23

CR29

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz

Page 12: Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union ... · • Mounting gaskets, drawings and instruction manual furnished. •All units use a CFC-free or environmentally safe

CUT-OUT NOTES

1. Dash lines represent

air conditioner.

2. Cut-out dimensions

for standard product

only.

3. Full-size mounting

template provided.

Stai

nles

s St

eel C

R23

CUT-OUT NOTES

1. Dash lines represent

air conditioner.

2. Cut-out dimensions

for standard product

only.

3. Full-size mounting

template provided.

CUT-OUT NOTES

1. Dash lines represent

air conditioner.

2. Cut-out dimensions

for standard product

only.

3. Full-size mounting

template provided.

SIDE MOUNT TO ENCLOSURE

For NEMA type 12 enclosure, interfacing air-out and

air-in openings are required in the enclosure wall.

SIDE MOUNT TO ENCLOSURE

For NEMA type 12 enclosure, interfacing air-out and

air-in openings are required in the enclosure wall.

SIDE MOUNT TO ENCLOSURE

For NEMA type 12 enclosure, interfacing air-out and

air-in openings are required in the enclosure wall.

TMSt

ainl

ess

Stee

l CR

29TM

Stai

nles

s St

eel C

R43

TMOrder from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz

Page 13: Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union ... · • Mounting gaskets, drawings and instruction manual furnished. •All units use a CFC-free or environmentally safe

DESIGN NOTES

1. Gasket kit for

mounting to enclosure

included.

▲2. Service cord

terminated with

appropriate plug cap.

▲4. Dashed lines

indicate optional shroud

used, along with other

special construction

features, for NEMA 4X.

Please contact factory

for details.

DESIGN NOTES

1. Gasket kit for

mounting to enclosure

included.

▲2. Service cord

terminated with

appropriate plug cap.

▲4. Dashed lines

indicate optional shroud

used, along with other

special construction

features, for NEMA 4X.

Please contact factory

for details.

DESIGN NOTES

1. Gasket kit for

mounting to enclosure

included.

▲2. Service cord

terminated with

appropriate plug cap.

▲4. Dashed lines

indicate optional shroud

used, along with other

special construction

features, for NEMA 4X.

Please contact factory

for details.

OU

TD

OO

R/C

ORR

OSI

VE/

STA

INLE

SS S

TEE

LC

R23,

CR

29,

CR

43

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz

Page 14: Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union ... · • Mounting gaskets, drawings and instruction manual furnished. •All units use a CFC-free or environmentally safe

FEATURES

• Stock models are equipped with a thermostat control that offers convenient digital

display of enclosure temperature and high temperature alarm (125ºF/52ºC). Flashing

display indicates alarm condition. EMI/RFI noise suppressor and UL/CUL and CE listing

are standard on stock models.

• New Genesis™ 33NSM and 36N models offer: improved aesthetics with no changes

to the major internal components so airflow and performance are the same as the

corresponding Slimboy models; unique condensate management system evaporates

moisture from enclosure and eliminates drain tubes, buckets and wet floors in typical

applications; and EZ Mount flanges simplify installation to a two-step, one-person job.

• Genesis™ units are directly interchangeable with the comparable Slimboy Series,

however, the Genesis 33NSM does not come equipped with a backplane like the old

Slimboy model.

• Narrow models offer a broad capacity range with the advantage of mounting on

narrow enclosures. The 33NSM Series is only 12" wide, and the 36N and 47N Series

are only 15" wide.

• High performance, industrial-grade ball bearing fans in the 33NSM, and high

performance blowers in the 36N and 47N, provide maximum heat transfer in densely

packed enclosures.

• Most components accessible by removing air filter.

• 100% functionally tested.

• Mounting gaskets, drawings and instruction manual furnished.

• All units use a CFC-free or environmentally safe refrigerant that is

universally accepted.

UL/CUL listing and CE standard on all Genesis™ 33NSM and 36N models.

(UL File SA6453) Please contact the factory. NEMA 12 per UL 50 type 12

approval on all models.

OTHER UNITS TO CONSIDER

Genesis™ 33NSM: 33 Water-Cooled, pg. 40

47N Series: 47 Water-Cooled, pg. 40

OPTIONS (SEE PGS. 80-81)

33NSM 36N 47N

Thermostat Package ✔ ✔ ✔

Thermostat/Malfunction Package ✔ ✔ ✔

Condensate Evaporator Package ** ** ✔

Special Voltage Package ✔ ✔ ✔

Outdoor Package* ✔ ✔ ✔

Corrosive Environment Package* ✔ ✔ ✔

Stainless Steel Package* ✔ ✔ ✔

Heater Package ✔ ✔ ✔

* Please refer to pgs. 36-39 for our air conditioners that have been engineered and manufacturedspecifically for demanding applications.

** A condensate management system is standard. See features.

NARROW Air Conditioners 4000-10000 BTU/HR.1172-2930 WATTS

47N

33NSM36N

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz

Page 15: Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union ... · • Mounting gaskets, drawings and instruction manual furnished. •All units use a CFC-free or environmentally safe

47N

GENESIS™ 33NSM Series4000 BTU/Hr. (1172 Watts) H x W x D: 34.37" (873) x 12" (305) x 9.88" (251)

Full BTU/Hr @ Max Shipping

Load Max Amb Amb Temp Weight

Model Voltage Hz Amps Phase Temp °F/°C Lbs/Kgs

M33-0416-G010 STOCK 115 50/60 13.0/13.2 1 3700/4000 125/52 105/48

M33-0416-G0XX 115 50/60 13.0/13.2 1 3700/4000 125/52 105/48

M33-0426-G009 STOCK 230 50/60 7.2/7.3 1 3700/4000 125/52 105/48

M33-0426-G0XX 230 50/60 7.2/7.3 1 3700/4000 125/52 105/48

-XX will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers.An “M” in the model number identifies the new Genesis™ Series of air conditioners.

GENESIS™ 36N Series6000 BTU/Hr. (1758 Watts) H x W x D: 38.72" (984) x 15" (381) x 11.33" (288)

Full BTU/Hr @ Max Shipping

Load Max Amb Amb Temp Weight

Model Voltage Hz Amps Phase Temp °F/°C Lbs/Kgs

M36-0616-307 STOCK 115 50/60 14.0/14.0 1 5000/6000 125/52 120/54

M36-0616-3XX 115 50/60 14.0/14.0 1 5000/6000 125/52 120/54

M36-0626-306 STOCK 230 50/60 7.0/7.0 1 5000/6000 125/52 120/54

M36-0626-3XX 230 50/60 7.0/7.0 1 5000/6000 125/52 120/54

-XX will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers.An “M” in the model number identifies the new Genesis™ Series of air conditioners.

47N Series8000-10000 BTU/Hr. (2344-2930 Watts) H x W x D: 49.13" (1248) x 15" (381) x 10.50" (267)

Full BTU/Hr @ Max Shipping

Load Max Amb Amb Temp Weight

Model Voltage Hz Amps Phase Temp °F/°C Lbs/Kgs

47-0815-3XX 115 50/60 18.0 1 6700/8000 125/52 150/68

47-0816-3XX 115 60 18.0 1 8000 125/52 150/68

47-0825-3XX 230 50 9.0 1 8000 125/52 150/68

47-0826-3XX 230 60 9.0 1 8000 125/52 150/68

47-1015-3XX 115 50/60 18.0 1 8300/10000 125/52 155/70

47-1016-3XX 115 60 18.0 1 10000 125/52 155/70

47-1025-3XX 230 50 10.0 1 10000 125/52 155/70

47-1026-3XX 230 60 9.0 1 10000 125/52 155/70

-XX will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers.Most models available with Hz selector switch, if desired. Contact factory.The 50/60 Hz units, because of the addition of an autotransformer, cost more than straight 60 Hz models. Units wired for 50 Hz operation when shipped. Asingle internal wiring change is required for 60 Hz operation.

AIR

CO

ND

ITIO

NE

RS

33N

SM

, 36N

, 47N

NA

RR

OWMcLEAN MIDWEST CLOSED-LOOP COOLING

Within the air conditioner, the recirculated clean enclosure air is kept separate

from the ambient airflow system. This protects the electronic controls and

prevents shutdowns caused by heat, humidity, dust and other contaminants.

33NSM

36N

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz

Page 16: Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union ... · • Mounting gaskets, drawings and instruction manual furnished. •All units use a CFC-free or environmentally safe

CUT-OUT NOTES

1. Cord is routed

through the 2" x 11.12"

return air opening (top).

2. Dash lines represent

air conditioner.

3. Cut-out dimensions

for standard product

only.

▲4. Bottom opening

will accommodate air

conditioner or heat

exchanger.

5. Full-size mounting

template provided.GEN

ESIS

™33

NSM

Ser

ies

GEN

ESIS

™36

N S

erie

s47

N S

erie

s

CUT-OUT NOTES

1. Service cord is

routed through the 3" x

14" return air opening.

2. Dash lines represent

air conditioner.

3. Cut-out dimensions

for standard product

only.

4. Full-size mounting

template provided.

CUT-OUT NOTES

1. Dash lines represent

air conditioner.

2. Cut-out dimensions

for standard product

only.

SIDE MOUNT TO ENCLOSURE

For NEMA type 12 enclosure, interfacing air-out and

air-in openings are required in the enclosure wall.

SIDE MOUNT TO ENCLOSURE

For NEMA type 12 enclosure, interfacing air-out and

air-in openings are required in the enclosure wall.

SIDE MOUNT TO ENCLOSURE

For NEMA type 12 enclosure, interfacing air-out and

air-in openings are required in the enclosure wall.

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz

Page 17: Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union ... · • Mounting gaskets, drawings and instruction manual furnished. •All units use a CFC-free or environmentally safe

DESIGN NOTES

1. Gasket kit for

mounting to enclosure

included.

▲2. Service cord.

▲3. This 25.58" x 11"

area is recessed 1.12"

from rear surface

(referred to as the

“plenum”).

▲5. Condenser air

discharge out front is

optional.

DESIGN NOTES

1. Gasket kit for

mounting to enclosure

included.

▲2. Service cord.

▲3. This 14" x 29.13"

area is recessed 1.44"

from rear surface

(referred to as the

“plenum”).

▲4. Condenser air

discharge out front is

optional.

DESIGN NOTES

1. Gasket kit for

mounting to enclosure

included.

2. Service cord

terminated with

appropriate plug cap.

▲3. This 36.13" x 14"

area is recessed 1.63"

from rear surface

(referred to as the

“plenum”).

NA

RR

OW

AIR

CO

ND

ITIO

NE

RS

33N

SM

, 36N

, 47N

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz

Page 18: Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union ... · • Mounting gaskets, drawings and instruction manual furnished. •All units use a CFC-free or environmentally safe

FEATURES

• Genesis™ 28 stock models are equipped with a thermostat control that offers

convenient digital display of enclosure temperature and high temperature alarm

(125ºF/52ºC). Flashing display indicates alarm condition. 36 Series stock models

have an electro-mechanical thermostat. Genesis™ 28 stock models are UL/CUL

and CE standard. Both Series include EMI/RFI noise suppressor on stock models.

• New Genesis™ 28 models offer: improved aesthetics with no changes to the

major internal components so airflow and performance are the same as the

corresponding Slimboy models; unique condensate management system

evaporates moisture from enclosure and eliminates drain tubes, buckets and wet

floors in typical applications; and EZ Mount flanges simplify installation to a two-

step, one-person job.

• Genesis™ units are directly interchangeable with the comparable Slimboy Series.

A field retrofit plate is needed only when mounting the Genesis™ 28 to an old

Slimboy model cutout. Plate is free upon request. For Slimboy 28 models with

side mounting rails, field retrofit plate part number is 28-plate. For other

mounting configurations, contact the factory.

• The Mid-Size models offer universal sizes and a broad performance range making

them some of the most popular in the industry.

• High CFM ball-bearing centrifugal blowers are ideal for densely packaged enclosures.

• Most components accessible by removing air filter.

• 100% functionally tested.

• Mounting gaskets, drawings and instruction manual furnished.

• All units use a CFC-free or environmentally safe refrigerant that is

universally accepted.

UL/CUL listing and CE standard on all Genesis™ 28 models. Certain 36 models

available with UL listing. (UL File SA6453). Please contact the factory.

NEMA 12 per UL 50 type 12 approval on all models.

OTHER UNITS TO CONSIDER

Genesis™ 28: CR29, pg. 16; CR29 Stainless Steel, pg. 36

36 Series: Genesis™ 36N, pg. 32

OPTIONS (SEE PGS. 80-81)

28 36

Thermostat Package ✔ ✔

Thermostat/Malfunction Package ✔ ✔

Condensate Evaporator Package ** ✔

Special Voltage Package ✔ ✔

Outdoor Package* ✔ ✔

Heater Package ✔ ✔

Corrosive Environment Package* ✔ ✔

Stainless Steel Package* ✔ ✔

* Please refer to pgs. 36-39 for our air conditioners that have been engineered and manufacturedspecifically for demanding applications.

** A condensate management system is standard. See features.

MID-SIZE Air Conditioners 2000-6000 BTU/HR.586-1758 WATTS

36

28

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz

Page 19: Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union ... · • Mounting gaskets, drawings and instruction manual furnished. •All units use a CFC-free or environmentally safe

36 Series6000 BTU/Hr. (1758 Watts) H x W x D: 36.69" (932) x 19" (483) x 10.88" (276)

Full BTU/Hr @ Max Shipping

Load Max Amb Amb Temp Weight

Model Voltage Hz Amps Phase Temp °F/°C Lbs/Kgs

36-0616-136 STOCK 115 60 14.0 1 6000 125/52 129/59

36-0615-1XX 115 50/60 14.0 1 5000/6000 125/52 131/59

36-0616-1XX 115 60 14.0 1 6000 125/52 126/57

36-0625-1XX 230 50 7.0 1 6000 125/52 126/57

36-0626-113 STOCK 230 60 7.0 1 6000 125/52 126/57

36-0626-1XX 230 60 7.0 1 6000 125/52 126/57

-XX will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers.Most models available with Hz selector switch, if desired. Contact factory.The 50/60 Hz units, because of the addition of an autotransformer, cost more than straight 60 Hz models. Units wired for 50 Hz operation when shipped. Asingle internal wiring change is required for 60 Hz operation.

McLEAN MIDWEST CLOSED-LOOP COOLING

Within the air conditioner, the

recirculated clean enclosure air is kept

separate from the ambient airflow

system. This protects the electronic

controls and prevents shutdowns caused

by heat, humidity, dust and other

contaminants.

3628

GENESIS™ 28 Series2000-6000 BTU/Hr. (586-1758 Watts) H x W x D: 28.50" (724) x 17" (432) x 11.33" (288)

Full BTU/Hr @ Max Shipping

Load Max Amb Amb Temp Weight

Model Voltage Hz Amps Phase Temp °F/°C Lbs/Kgs

M28-0216-G013 STOCK 115 50/60 9.8/9.0 1 2200/2200 125/52 98/45

M28-0216-G0XX 115 50/60 9.8/9.0 1 2200/2200 125/52 98/45

M28-0226-G004 STOCK 230 50/60 5.0/4.5 1 2200/2200 125/52 98/45

M28-0226-G0XX 230 50/60 5.0/4.5 1 2200/2200 125/52 98/45

M28-0416-G007 STOCK 115 50/60 14.6/14.0 1 3800/4000 125/52 116/53

M28-0416-G0XX 115 50/60 14.6/14.0 1 3800/4000 125/52 116/53

M28-0426-G032 STOCK 230 50/60 7.4/6.9 1 3800/4000 125/52 116/53

M28-0426-G0XX 230 50/60 7.4/6.9 1 3800/4000 125/52 116/53

M28-0616-0XX 115 50/60 15.0/15.0 1 5400/6000 125/52 120/55

M28-0626-0XX 230 50/60 7.3/7.3 1 5400/6000 125/52 120/55

-XX will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers.An “M” in the model number identifies the new Genesis™ Series of air conditioners.

MID

-SIZ

EA

IR C

ON

DIT

ION

ER

S28,

36

❑ Ambient air flow❑ Clean air flow

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz

Page 20: Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union ... · • Mounting gaskets, drawings and instruction manual furnished. •All units use a CFC-free or environmentally safe

GENESIS™ 28 Series

CUT-OUT NOTES

1. Dash lines represent

air conditioner.

2. Cut-out dimensions

for standard product

only.

▲3. This hole may be

deleted if the service

cord is routed through

the 3" x 13.50" return

air opening.

4. Full-size mounting

template provided.

DESIGN NOTES

1. Gasket kit for mounting to enclosure included.

▲2. Service cord.

▲4. This 20.50" x 15.50" area is recessed 1.00" from rear surface (referred to as the “plenum”).

▲5. Condenser air discharge out front is optional.

SIDE MOUNT TO ENCLOSURE

For NEMA type 12 enclosure, interfacing air-out and

air-in openings are required in the enclosure wall.

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz

Page 21: Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union ... · • Mounting gaskets, drawings and instruction manual furnished. •All units use a CFC-free or environmentally safe

36 Series

CUT-OUT NOTES

▲1. This cord hole may

be deleted if the service

cord is routed through

the 3" x 16.75" return

air opening.

2. Dash lines represent

air conditioner.

3. Cut-out dimensions

for standard product

only.

DESIGN NOTES

1. Gasket kit for mounting to enclosure included.

2. Service cord terminated with appropriate plug cap.

▲3. This 30.06" x 16.75" area is recessed .94" from rear surface (referred to as the “plenum”).

SIDE MOUNT TO ENCLOSURE

For NEMA type 12 enclosure, interfacing air-

out and air-in openings are required in the

enclosure wall.

MID

-SIZ

EA

IR C

ON

DIT

ION

ER

S28,

36

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz

Page 22: Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union ... · • Mounting gaskets, drawings and instruction manual furnished. •All units use a CFC-free or environmentally safe

FEATURES

• Stock models are equipped with a thermostat control that offers convenient

digital display of enclosure temperature and high temperature alarm (125ºF/52ºC).

Flashing display indicates alarm condition. EMI/RFI noise suppressor and UL/CUL

and CE are standard on stock models of 6,000 and 8,000 BTU/Hr. models. On

10,000 and 12,000 BTU/Hr. models of the Genesis 52 Series, the 115 volt stock

model is UR/CUR recognized.

• New Genesis™ 52 models offer: improved aesthetics with no changes to the

major internal components so airflow and performance are the same as the

corresponding Slimboy models; unique condensate management system

evaporates moisture from enclosure and eliminates drain tubes, buckets and wet

floors in typical applications; and EZ Mount flanges simplify installation to a two-

step, one-person job.

• Genesis™ units are directly interchangeable with the comparable Slimboy Series.

A field retrofit plate is needed only when mounting the Genesis™ 52 to an old

Slimboy model cutout. Plate is free upon request. For Slimboy 52 models with

side mounting rails, field retrofit plate part number is 52-plate. For other

mounting configurations, contact the factory.

• Full-Size models offer the highest cooling capacities in McLean's extensive air

conditioner range.

• McLean’s highest performance CFM ball-bearing centrifugal blowers are ideal for

densely packed enclosures.

• Most components accessible by removing air filter.

• 100% functionally tested.

• Mounting gaskets, drawings and instruction manual furnished.

• All units use a CFC-free or environmentally safe refrigerant that is

universally accepted.

UL/CUL listing and CE standard on most Genesis™ 52 models, except the 115 volt,

Genesis 52 series in the 10,000 and 12,000 BTU/Hr. which are UR/CUR

recognized. Certain 52HC models available with UL listing. (UL File SA6453)

Please contact the factory. NEMA 12 per UL 50 type 12 approval on all models.

OPTIONS (SEE PGS. 80-81)

52 52HC

Thermostat Package ✔ ✔

Thermostat/Malfunction Package ✔ ✔

Condensate Evaporator Package ** ✔

Special Voltage Package ✔ ✔

Outdoor Package* ✔ ✔

Corrosive Environment Package* ✔ ✔

Stainless Steel Package* ✔ ✔

Heater Package ✔ ✔

* Please refer to pgs. 36-39 for our air conditioners that have been engineered and manufacturedspecifically for demanding applications.

** A condensate management system is standard. See features.

FULL-SIZE Air Conditioners 6000-20000 BTU/HR.1758-5860 WATTS

52HC52

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz

Page 23: Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union ... · • Mounting gaskets, drawings and instruction manual furnished. •All units use a CFC-free or environmentally safe

52HC Series14000-20000 BTU/Hr. (4100-5860 Watts) H x W x D: 52.50" (1333) x 23" (584) x 12.88" (327)

Full BTU/Hr @ Max Shipping

Load Max Amb Amb Temp Weight

Model Voltage Hz Amps Phase Temp °F/°C Lbs/Kgs

52-1425-0XX 230 50 14.0 1 14000 125/52 220/100

52-1426-0XX 230 60 14.0 1 14000 125/52 220/100

52-1625-0XX 230 50 16.0 1 16000 125/52 225/102

52-1626-0XX 230 60 17.0 1 16000 125/52 225/102

52-1926-0XX 230 50/60 18.8/18.8 1 17500/20000 125/52 235/107

-XX will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers.

McLEAN MIDWEST

CLOSED-LOOP COOLING

Within the air conditioner, the recirculated clean

enclosure air is kept separate from the ambient

airflow system. This protects the electronic

controls and prevents shutdowns caused by heat,

humidity, dust and other contaminants.

GENESIS™ 52 Series6000-12000 BTU/Hr. (1758-3516 Watts) H x W x D: 52.63" (1337) x 17.13" (435) x 11.33" (288)

Full BTU/Hr @ Max Shipping

Load Max Amb Amb Temp Weight

Model Voltage Hz Amps Phase Temp °F/°C Lbs/Kgs

M52-0616-0XX 115 50/60 13.0/13.0 1 5000/6000 125/52 155/70

M52-0626-0XX 230 50/60 6.5/6.5 1 5000/6000 125/52 155/70

M52-0816-032 STOCK 115 50/60 14.5/14.5 1 6700/8000 125/52 160/73

M52-0816-0XX 115 50/60 14.5/14.5 1 6700/8000 125/52 160/73

M52-0826-015 STOCK 230 50/60 8.0/8.0 1 6700/8000 125/52 160/73

M52-0826-0XX 230 50/60 8.0/8.0 1 6700/8000 125/52 160/73

M52-1016-038 STOCK 110/115 50/60 18.9/19.5 1 8300/10000 125/52 165/75

M52-1016-0XX 110/115 50/60 18.9/19.5 1 8300/10000 125/52 165/75

M52-1026-021 STOCK 220/230 50/60 9.5/9.8 1 8300/10000 125/52 165/75

M52-1026-0XX 220/230 50/60 9.5/9.8 1 8300/10000 125/52 165/75

M52-1216-017 STOCK 110/115 50/60 24.0/23.0 1 10000/12000* 125/52 175/79

M52-1216-0XX 110/115 50/60 24.0/23.0 1 10000/12000* 125/52 175/79

M52-1226-034 STOCK 220/230 50/60 12.0/11.6 1 10000/12000* 125/52 175/79

M52-1226-0XX 220/230 50/60 12.0/11.6 1 10000/12000* 125/52 175/79

-XX will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers.Most models available with Hz selector, if desired. Contact factory.The 50/60 Hz units, because of the addition of an autotransformer, cost more than straight 60 Hz models. Units wired for 50 Hz operation when shipped. Asingle internal wiring change is required for 60 Hz operation.* Based on return air temperature slightly above ambient.An “M” in the model number identifies the new Genesis™ Series of air conditioners.

FU

LL

-SIZ

EA

IR C

ON

DIT

ION

ER

S52,

52H

C

❑ Ambient air flow❑ Clean air flow

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz

Page 24: Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union ... · • Mounting gaskets, drawings and instruction manual furnished. •All units use a CFC-free or environmentally safe

GENESIS™ 52 Series

CUT-OUT NOTES

1. Dash lines represent

air conditioner.

2. Cut-out dimensions

for standard product

only.

▲3. This cord hole may

be deleted if the service

cord is routed through

the 4.50" x 15.63" return

air opening (except units

with electric heat).

4. Full-size mounting

template provided.

DESIGN NOTES

1. Gasket kit for mounting to enclosure included.

▲2. Service cord.

▲3. This 42.06" x 15.63" area is recessed 1.44" from rear surface (referred to as the “plenum”).

▲4. Condenser air discharge out front is optional.

SIDE MOUNT TO ENCLOSURE

For NEMA type 12 enclosure, interfacing air-out and

air-in openings are required in the enclosure wall.

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz

Page 25: Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union ... · • Mounting gaskets, drawings and instruction manual furnished. •All units use a CFC-free or environmentally safe

52HC Series

CUT-OUT NOTES

1. Dash lines represent

air conditioner.

2. Cut-out dimensions

for standard product

only.

DESIGN NOTES

1. Gasket kit for mounting to enclosure included.

▲2. This 47" x 20.88" area is recessed 1.69" from rear surface (referred to as the “plenum”).

3. Service cord terminated with appropriate plug cap.

* Dimensional changes required to accommodate autotransformer on 50/60 Hz units.

SIDE MOUNT TO ENCLOSURE

For NEMA type 12 enclosure, interfacing air-

out and air-in openings are required in the

enclosure wall. Refer to mounting dimensions.

FU

LL

-SIZ

EA

IR C

ON

DIT

ION

ER

S52,

52H

C

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz

Page 26: Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union ... · • Mounting gaskets, drawings and instruction manual furnished. •All units use a CFC-free or environmentally safe

1713

FEATURES

• Stock models are equipped with a thermostat control that offers convenientdigital display of enclosure temperature and high temperature alarm (125ºF/52ºC).Flashing display indicates alarm condition. EMI/RFI noise suppressor and UL/CULand CE are standard on stock models.

• New Genesis™ models offer improved aesthetics with no changes to the majorinternal components so airflow and performance are the same as thecorresponding Slimboy models.

• Genesis™ units are directly interchangeable with the comparable Slimboy Series.

• Unique condensate management system evaporates moisture from enclosure andeliminates drain tubes, buckets and wet floors in typical applications.

• Compact models are ideal for cooling smaller enclosures from 25 cu. ft. to 40 cu.ft. The ultra-narrow 17 Series is only 12" wide making it perfect for enclosureswith narrow side walls.

• EZ Mount flanges simplify installation to a two-step, one-person job.

• High-performance, industrial-grade ball-bearing fans used to provide maximumheat transfer.

• Most components accessible by removing grille/filter.

• 100% functionally tested.

• Mounting hardware, gaskets, drawings, mounting template and instruction manualfurnished.

• All units use a CFC-free or environmentally safe refrigerant that is universally accepted.

UL/CUL listing and CE standard on all models. (UL File SA6453).

Please contact the factory. NEMA 12 per UL 50 type 12 approval on all models.

OTHER UNITS TO CONSIDER

Genesis™ 17: CR23, pg. 16; CR23 Stainless Steel, pg. 36

OPTIONS (SEE PGS. 80-81)

13 17

Thermostat Package ✔ ✔

Thermostat/Malfunction Package ✔ ✔

Special Voltage Package ✔ ✔

Outdoor Package* ✔ ✔

Corrosive Environment Package* ✔ ✔

Stainless Steel Package* ✔ ✔

* Please refer to pgs. 36-39 for our air conditioners that have been engineered and manufacturedspecifically for demanding applications.

COMPACT Air Conditioners 1000-1800 BTU/HR.293-527 WATTS

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz

Page 27: Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union ... · • Mounting gaskets, drawings and instruction manual furnished. •All units use a CFC-free or environmentally safe

McLEAN MIDWEST CLOSED-LOOP COOLING

Within the air conditioner, the recirculated clean enclosure air is kept separate

from the ambient airflow system. This protects the electronic controls and

prevents shutdowns caused by heat, humidity, dust and other contaminants.

AIR

CO

ND

ITIO

NE

RS

13,

17

1713

GENESIS™ 13 Series1000 BTU/Hr. (293 Watts) H x W x D: 13.25" (337) x 14.25" (362) x 7.80" (198)

Full BTU/Hr @ Max Shipping

Load Max Amb Amb Temp Weight

Model Voltage Hz Amps Phase Temp °F/°C Lbs/Kgs

M13-0116-G1014 STOCK 115 50/60 4.0/4.0 1 800/1000 125/52 48/22

M13-0116-G1XXX 115 50/60 4.0/4.0 1 800/1000 125/52 48/22

M13-0126-G1008 STOCK 230 50/60 2.2/2.1 1 800/1000 125/52 48/22

M13-0126-G1XXX 230 50/60 2.2/2.1 1 800/1000 125/52 48/22

-XXX will be replaced with a three-digit number designating all desired options. Consult the factory for specific model numbers.An “M” in the model number identifies the new Genesis™ Series of air conditioners.

GENESIS™ 17 Series1800 BTU/Hr. (527 Watts) H x W x D: 17.65" (448) x 12" (305) x 8.68" (220)

Full BTU/Hr @ Max Shipping

Load Max Amb Amb Temp Weight

Model Voltage Hz Amps Phase Temp °F/°C Lbs/Kgs

M17-0216-G009 STOCK 110/115 50/60 6.6/6.7 1 1500/1800 125/52 56/25

M17-0216-G0XX 110/115 50/60 6.6/6.7 1 1500/1800 125/52 56/25

M17-0226-G004 STOCK 220/230 50/60 4.2/3.7 1 1500/1800 125/52 56/25

M17-0226-G0XX 220/230 50/60 4.2/3.7 1 1500/1800 125/52 56/25

-XX will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers.An "M" in the model number identifies the new Genesis™ Series of air conditioners.

CO

MPA

CT

❑ Ambient air flow❑ Clean air flow

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz

Page 28: Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union ... · • Mounting gaskets, drawings and instruction manual furnished. •All units use a CFC-free or environmentally safe

GENESIS™ 13 Series

CUT-OUT NOTES

1. Dash lines represent

air conditioner.

2. Cut-out dimensions

for standard product

only.

3. Full-size mounting

template provided.

DESIGN NOTES

1. Gasket kit for mounting to enclosure included.

▲2. Service cord.

SIDE MOUNT TO ENCLOSURE

For NEMA type 12 enclosure, interfacing air-out and

air-in openings are required in the enclosure wall.

Generally, the 13 Series is most effective on

enclosures up to 25 cu. ft., unless the application is

only for spot cooling in a larger enclosure.

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz

Page 29: Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union ... · • Mounting gaskets, drawings and instruction manual furnished. •All units use a CFC-free or environmentally safe

GENESIS™ 17 Series

CUT-OUT NOTES

1. Dash lines represent

air conditioner.

2. Cut-out dimensions

for standard product

only.

3. Full-size mounting

template provided.

DESIGN NOTES

1. Gasket kit for mounting to enclosure included.

▲2. Service cord.

3. Condensate from enclosure drains to bottom pan of unit where it is evaporated by condenser heat.

SIDE MOUNT TO ENCLOSURE

For NEMA type 12 enclosure, interfacing air-

out and air-in openings are required in the

enclosure wall. Generally, the 17 Series is

most effective on enclosures up to 40 cu. ft.,

unless the application is only for spot cooling

in a larger enclosure.

CO

MPA

CT

A

IR C

ON

DIT

ION

ER

S13,

17

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz

Page 30: Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union ... · • Mounting gaskets, drawings and instruction manual furnished. •All units use a CFC-free or environmentally safe

HB11

FEATURES

• Stock HB11 models are equipped with a thermostat control that offers

convenient digital display of enclosure temperature and high temperature alarm

(125ºF/52ºC). Flashing display indicates alarm condition. EMI/RFI noise suppressor

and UR/CUR and CE are standard on stock models.

• New Genesis™ HB11 models offer: improved aesthetics with no changes to the

major internal components so airflow and performance are the same as the

corresponding Slimboy model.

• Genesis™ units are directly interchangeable with the comparable Slimboy Series.

• HB11 and HB30 models have a unique condensate management system that

evaporates moisture from enclosure and eliminates drain tubes, buckets and wet

floors in typical applications.

• Top-Mount air conditioners are ideal for use where there is little or no clearance

around the enclosure.

• High CFM ball-bearing centrifugal blowers are ideal for densely packaged enclosures.

• 100% functionally tested.

• Mounting gaskets, drawings and instruction manual furnished.

• All units use a CFC-free or environmentally safe refrigerant that is

universally accepted.

UL recognized, CUL recognized and CE standard on all Genesis™ HB11 models.

Certain HB16 models available with UL listing. (UL File SA6453) Please contact the

factory. NEMA 12 per UL 50 type 12 approval on all models.

OPTIONS (SEE PGS. 80-81)

HB11 HB16 HB30

Thermostat Package ✔ ✔ ✔

Thermostat/Malfunction Package ✔ ✔ ✔

Special Voltage Package ✔ ✔ ✔

Corrosive Environment Package* ✔ ✔ ✔

Stainless Steel Package* ✔ ✔ ✔

Heater Package ✔ ✔ ✔

* Please refer to pgs. 36-39 for our air conditioners that have been engineered and manufacturedspecifically for demanding applications.

TOP-MOUNT Air Conditioners 2000-9000 BTU/HR.586-2637 WATTS

McLEAN MIDWEST CLOSED-LOOP COOLING

Within the air conditioner, the recirculated clean enclosure air is kept separate

from the ambient airflow system. This protects the electronic controls and

prevents shutdowns caused by heat, humidity, dust and other contaminants.

HB16HB30

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz

Page 31: Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union ... · • Mounting gaskets, drawings and instruction manual furnished. •All units use a CFC-free or environmentally safe

AIR

CO

ND

ITIO

NE

RS

HB

11,

HB

16,

HB

30

GENESIS™ HB11 Series2000-4000 BTU/Hr. (586-1172 Watts) H x W x D: 10.25" (260) x 17" (432) x 21.08" (535)

Full BTU/Hr @ Max Shipping

Load Max Amb Amb Temp Weight

Model Voltage Hz Amps Phase Temp °F/°C Lbs/Kgs

MHB11-0216-G306 STOCK 115 50/60 9.7/9.0 1 2200/2200 125/52 90/41

MHB11-0216-G3XX 115 50/60 9.7/9.0 1 2200/2200 125/52 90/41

MHB11-0226-G306 STOCK 230 50/60 5.5/4.6 1 2200/2200 125/52 90/41

MHB11-0226-G3XX 230 50/60 5.5/4.6 1 2200/2200 125/52 90/41

MHB11-0416-G307 STOCK 110/115 50/60 14.7/13.6 1 3300/4000 125/52 108/49

MHB11-0416-G3XX 110/115 50/60 14.7/13.6 1 3300/4000 125/52 108/49

MHB11-0426-G306 STOCK 220/230 50/60 8.0/7.5 1 3300/4000 125/52 108/49

MHB11-0426-G3XX 220/230 50/60 8.0/7.5 1 3300/4000 125/52 108/49

-XX will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers.An “M” in the model number identifies the new Genesis™ Series of air conditioners.

HB16 Series6000-9000 BTU/Hr. (1758-2637 Watts) H x W x D: 15.72" (399) x 19" (483) x 25.19" (640)

Full BTU/Hr @ Max Shipping

Load Max Amb Amb Temp Weight

Model Voltage Hz Amps Phase Temp °F/°C Lbs/Kgs

HB16-0615-0XX 115 50/60 13.0 1 5000/6000 125/52 145/66

HB16-0616-0XX 115 60 13.0 1 6000 125/52 140/64

HB16-0625-0XX 230 50 6.5 1 6000 125/52 140/64

HB16-0626-0XX 230 60 6.5 1 6000 125/52 140/64

HB16-0825-0XX 230 50 8.0 1 8000 125/52 145/66

HB16-0915-0XX 115 50/60 17.0 1 8500/9000 125/52 150/68

HB16-0916-0XX 115 60 19.0 1 9000 125/52 145/66

HB16-0926-0XX 230 60 9.5 1 9000 125/52 145/66

-XX will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers.Most models available with Hz selector, if desired. Contact factory.The 50/60 Hz units, because of the addition of an autotransformer, cost more than straight 60 Hz models. Units wired for 50 Hz operation when shipped. Asingle internal wiring change is required for 60 Hz operation.

HB30 Series6000 BTU/Hr. (1758 Watts) H x W x D: 14.13" (359) x 31.38" (797) x 15" (381)

Full BTU/Hr @ Max Shipping

Load Max Amb Amb Temp Weight

Model Voltage Hz Amps Phase Temp °F/°C Lbs/Kgs

HB30-0615-1XX 115 50/60 14.0 1 5000/6000 125/52 136/62

HB30-0616-1XX 115 60 14.0 1 6000 125/52 131/59

HB30-0625-1XX 230 50 7.0 1 6000 125/52 131/59

HB30-0626-1XX 230 60 7.0 1 6000 125/52 131/59

-XX will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers.Most models available with Hz selector, if desired. Contact factory.The 50/60 Hz units, because of the addition of an autotransformer, cost more than straight 60 Hz models. Units wired for 50 Hz operation when shipped. Asingle internal wiring change is required for 60 Hz operation.

TO

P-M

OU

NT

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz

Page 32: Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union ... · • Mounting gaskets, drawings and instruction manual furnished. •All units use a CFC-free or environmentally safe

CUT-OUT NOTES

1. Dash lines represent

air conditioner.

2. Cut-out dimensions

for standard product

only.

3. Full-size mounting

template provided.

GE

NE

SIS

™H

B11 S

ER

IES

HB

16 S

ER

IES

HB

30 S

ER

IES

CUT-OUT NOTES

1. Dash lines represent

air conditioner.

2. Entire weight of air

conditioner is not

intended to be

supported by the

mounting flanges. Slide

rails should be installed.

▲3. Cut-out and duct

or gasket required on

enclosure for condenser

air discharge.

4. Cut-out dimensions

for standard product

only.

CUT-OUT NOTES

1. Dash lines represent

air conditioner.

2. Cut-out dimensions

for standard product

only.

TOP SURFACE MOUNT TO

ENCLOSURE

For NEMA type 12 enclosure, interfacing air-out and

air-in openings are required in the enclosure top.

INTERNAL MOUNT

TO ENCLOSURE

For internal top mounting to NEMA

type 12 enclosures, slide rails should

be used. Cool air blows down.

TOP SURFACE

MOUNT TO

ENCLOSURE

For top mounting of air

conditioner, interfacing

air-out and air-in openings

are required in the top of

the enclosure. Special filter

frame required, consult

factory about model

specifications.

TOP SURFACE MOUNT

TO ENCLOSURE

For top mounting of air conditioner,

interfacing air-out and air-in openings are

required in the enclosure top surface.

TOP RECESSED

MOUNT TO

ENCLOSURE

Cool air blows down.

Consult factory when

ordering Series 30

RM. Air conditioner is

8.5" standard onto

the enclosure.

INTERNAL MOUNT

TOP SURFACE MOUNT

TOP RECESSED MOUNT

TOP SURFACE MOUNT

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz

Page 33: Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union ... · • Mounting gaskets, drawings and instruction manual furnished. •All units use a CFC-free or environmentally safe

DESIGN NOTES

1. Gasket kit for

mounting to enclosure

included.

▲2. Service cord.

3. Condensate from

enclosure drains to

bottom pan of unit

where it is evaporated

by condenser heat.

4. Condensate

overflow drain hose

included.

DESIGN NOTES

1. Gasket kit for

mounting to enclosure

included.

2. Service cord

terminated with

appropriate plug cap.

3. Condensate drain

hose with a “P” trap

included.

DESIGN NOTES

1. Gasket kit for

mounting to enclosure

included.

2. Service cord

terminated with

appropriate plug cap.

3. Condensate drain

hose included.

4. Unit is available

surface mounted as

shown or in partially

recessed mount

configuration.

AIR

CO

ND

ITIO

NE

RS

HB

11,

HB

16,

HB

30

TO

P-M

OU

NT

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz

Page 34: Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union ... · • Mounting gaskets, drawings and instruction manual furnished. •All units use a CFC-free or environmentally safe

AIR

CO

ND

ITIO

NE

RS

RC

R11,

LB

14,

LB

16

RCR11 LB14 LB16

RCR11 Series2000-4000 BTU/Hr. (586-1172 Watts) H x W x D: 10.47" (266) x 19" (483) x 21.47" (545)

Max Shipping

BTU/Hr @ Amps @ BTU/Hr @ Amps @ Amb Temp Weight

Model Voltage Hz Phase 131°F/131°F* 131°F/131°F 95°F/95°F* 95°F/95°F °F/°C Lbs/Kgs

RCR11-0216-G002 STOCK 115 50/60 1 1800/2000 9.0/9.0 1800/2000 8.0/7.4 131/55 95/43

RCR11-0216-G0XX 115 50/60 1 1800/2000 9.0/9.0 1800/2000 8.0/7.4 131/55 95/43

RCR11-0226-G0XX 230 50/60 1 1800/2000 5.1/4.7 1800/2000 4.7/3.9 131/55 95/43

RCR11-0416-G002 STOCK 115 50/60 1 3800/4000 12.9/12.9 3500/3500 11.1/9.9 131/55 107/49

RCR11-0416-G0XX 115 50/60 1 3800/4000 12.9/12.9 3500/3500 11.1/9.9 131/55 105/48

RCR11-0426-G0XX 230 50/60 1 3800/4000 7.1/7.1 3500/3500 5.6/5.0 131/55 105/48

-XX will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers.*Because air conditioners provide less cooling at lower operating temperatures, two cooling capacity ratings are listed for each ProAir™ air conditioner toassist you in your selection.

LB14 Series7000 BTU/Hr. (2051 Watts) H x W x D: 14.75" (375) x 19" (483) x 23.63" (600)

Full BTU/Hr @ Max Shipping

Load Max Amb Amb Temp Weight

Model Voltage Hz Amps Phase Temp °F/°C Lbs/Kgs

LB14-0715-0XX 115 50/60 15.0 1 5800/7000 125/52 140/64

LB14-0716-0XX 115 60 15.0 1 7000 125/52 135/61

LB14-0725-0XX 230 50 8.0 1 7000 125/52 135/61

LB14-0726-0XX 230 60 7.5 1 7000 125/52 135/61

-XX will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers.Most models available with Hz selector, if desired. Contact factory.The 50/60 Hz units, because of the addition of an autotransformer, cost more than straight 60 Hz models. Units wired for 50 Hz operation when shipped. Asingle internal wiring change is required for 60 Hz operation.

LB16 Series10000 BTU/Hr. (2930 Watts) H x W x D: 15.72" (399) x 19" (483) x 25.19" (640)

Full BTU/Hr @ Max Shipping

Load Max Amb Amb Temp Weight

Model Voltage Hz Amps Phase Temp °F/°C Lbs/Kgs

LB16-1016-0XX 115 60 20.0 1 10000 125/52 140/64

LB16-1025-0XX 230 50 10.0 1 10000 125/52 140/64

LB16-1026-0XX 230 60 10.0 1 10000 125/52 140/64

-XX will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers.Most models available with Hz selector, if desired. Contact factory.The 50/60 Hz units, because of the addition of an autotransformer, cost more than straight 60 Hz models. Units wired for 50 Hz operation when shipped. Asingle internal wiring change is required for 60 Hz operation.

RA

CK

-MO

UN

T

TM

❑ Ambient air flow❑ Clean air flow

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz

Page 35: Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union ... · • Mounting gaskets, drawings and instruction manual furnished. •All units use a CFC-free or environmentally safe

CUT-OUT NOTES

1. An envelope of

clean, cool air can

circulate around the

enclosed electronics

without the need for

additional baffling,

ducting or special

arrangement of enclosed

components.

RC

R11 S

ER

IES

LB

14 S

ER

IES

LB

16 S

ER

IES

CUT-OUT NOTES

1. Dash lines represent

air conditioner.

2. Entire weight of air

conditioner is not

intended to be

supported by the

mounting flanges. Slide

rails should be installed.

3. Cut-out dimensions

for standard product

only.

CUT-OUT NOTES

1. Dash lines

represent air

conditioner.

2. Entire weight of air

conditioner is not

intended to be

supported by the

mounting flanges. Slide

rails should be installed.

▲3. Cut-out and duct

or gasket required on

enclosure for condenser

air discharge.

4. Cut-out dimensions

for standard product

only.

RACK MOUNT TO ENCLOSURE

Patented airflow system will direct cool air

throughout enclosure allowing unit to be rack-

mounted at any location in enclosure.

RACK MOUNT TO ENCLOSURE

For mounting air conditioner to NEMA type 12

enclosure, slide rails should be installed. Cool air

blows up.

RACK MOUNT TO ENCLOSURE

For mounting air conditioner to NEMA type 12

enclosure, slide rails should be installed. Cool air

blows up.

TMOrder from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz

Page 36: Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union ... · • Mounting gaskets, drawings and instruction manual furnished. •All units use a CFC-free or environmentally safe

DESIGN NOTES

1. Gasket kit for

mounting to enclosure

included.

2. Service cord

terminated with

appropriate plug cap.

3. Required opening in

enclosure: 13.75" x

17.38"; minimum

enclosure depth: 25".

DESIGN NOTES

1. Gasket kit for

mounting to enclosure

included.

2. Service cord

terminated with

appropriate plug cap.

AIR

CO

ND

ITIO

NE

RS

RC

R11,

LB

14,

LB

16

RA

CK

-MO

UN

T

DESIGN NOTES

1. Gasket kit for

mounting to enclosure

included.

2. Service cord

terminated with

appropriate plug cap.

3. Condensate from

enclosure drains to

bottom pan of unit where

it is evaporated into

condenser air discharge.

4. Evaporator side

discharge chutes hinge

outward and are

reversible to allow

direction of air up or

down. Units are shipped

with chutes pointed up.

To direct air downward,

remove mounting screw

and exchange left and

right chutes. Reinstall

mounting screw in upper

hole.

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz