order from cuny & guerber inc., 2100 kerrigan ave., union ... · • mounting gaskets, drawings...
TRANSCRIPT
RCR11
FEATURES
• RCR11 is part of the ProAir™ Series which combines state-of-the-art design
with pleasing aesthetics. This rack mount model is an excellent, high-efficiency
model with a patented airflow system that allows it to be mounted anywhere
within the enclosure. RCR11 stock models have thermostat control and EMI/RFI
noise suppressor.
• Rack mount models are ideal when it is important to keep an application
self-contained within the enclosure.
• Unique condensate management system evaporates moisture from enclosure to
ambient air eliminating drain tubes, buckets and wet floors.
• High CFM blowers are used for maximum airflow throughout enclosure.
• 100% functionally tested.
• Mounting gaskets, drawings and instruction manual furnished.
• All units use a CFC-free or environmentally safe refrigerant that is
universally accepted.
Some LB16 Series and LB14 Series models available with UL listing at additional
cost. (UL File SA6453) Please contact the factory. NEMA 12 per UL 50 Type 12
approval on all models.
OPTIONS (SEE PGS. 80-81)
RCR11 LB14 LB16
Thermostat Package ✔ ✔ ✔
Thermostat/Malfunction Package ✔ ✔ ✔
Special Voltage Package ✔ ✔ ✔
Corrosive Environment Package ✔ ✔ ✔
Stainless Steel Package ✔ ✔ ✔
Heater Package ✔ ✔ N/A
RACK-MOUNT Air Conditioners 2000-10000 BTU/HR.586-2930 WATTS
McLEAN MIDWEST CLOSED-LOOP COOLING
Within the air conditioner, the recirculated clean enclosure air is kept separate
from the ambient airflow system. This protects the electronic controls and
prevents shutdowns caused by heat, humidity, dust and other contaminants.
LB16 LB14
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz
FEATURES
• Water-Cooled air conditioners are for especially hostile, dirty environments or
where temperatures exceed 125°F/52°C. Varied sizes, capacities and mounting
options provide a wide range of choice.
• 33WC and 47WC Series are side-mount models, and the LB11WC is a rack
mount unit.
• 33WC will mount to 12" deep enclosure.
• Operate quietly, consume low power, no condenser blower or filter to clean, and
have an extra-long operating life.
• Add no heat to surroundings and require no fresh air ducting.
• Water regulating valve and water interruption shut-down switch is standard.
• 100% functionally tested.
• Mounting gaskets, drawings and instruction manual furnished.
• All units use a CFC-free or environmentally safe refrigerant that is
universally accepted.
NEMA 12 per UL 50 Type 12 approval on all models.
OTHER UNITS TO CONSIDER
33 Water-Cooled: Genesis™ 33NSM, pg. 32
47 Water-Cooled: 47N Series, pg. 32
OPTIONS (SEE PGS. 80-81)
33WC 47WC LB11WC
Thermostat Package ✔ ✔ ✔
Thermostat/Malfunction Package ✔ ✔ ✔
Condensate Evaporator Package ✔ ✔ N/A
Special Voltage Package ✔ ✔ ✔
Corrosive Environment Package* ✔ ✔ ✔
Stainless Steel Package* ✔ ✔ ✔
Heater Package ✔ ✔ ✔
* Please refer to pgs. 36-39 for our air conditioners that have been engineered and manufacturedspecifically for demanding applications.
4000-12000 BTU/HR.1172-3516 WATTS
LB11WC33WC
47WC
WATER-COOLED Air Conditioners
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz
33WC Series4000 BTU/Hr. (1172 Watts) H x W x D: 34.13" (867) x 12.38" (314) x 8.75" (222)
Full BTU/Hr @ Max °F/°C Max Water Shipping
Load 125°F Enclosure Water Usage Weight
Model Voltage Hz Amps Phase Air Temp Temp (GPM)* Lbs/Kgs
33-0416-GW0XX 115 50/60 6.0/5.8 1 3800/4000 90/32 0.5 86/39
33-0426-GW0XX 230 50/60 3.3/3.2 1 3800/4000 90/32 0.5 86/39
-XX will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers.*Rated at 90°F inlet water and full air conditioning load. Actual usage will vary.
LB11WC Series4000 BTU/Hr. (1172 Watts) H x W x D: 10.47" (266) x 19" (483) x 19.63" (499)
Full BTU/Hr @ Max °F/°C Max Water Shipping
Load 125°F Enclosure Water Usage Weight
Model Voltage Hz Amps Phase Air Temp Temp (GPM)* Lbs/Kgs
LB11-0416-GW0XX 115 50/60 9.0 1 3300/4000 90/38 1.0 105/48
LB11-0426-GW0XX 230 50/60 4.5 1 3300/4000 90/38 1.0 100/45
-XX will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers.*Rated at 90°F inlet water and full air conditioning load. Actual usage will vary.
47WC Series8000-12000 BTU/Hr. (2344-3516 Watts) H x W x D: 47.25" (1200) x 19" (483) x 10" (254)
Full BTU/Hr @ Max °F/°C Max Water Shipping
Load 125°F Enclosure Water Usage Weight
Model Voltage Hz Amps Phase Air Temp Temp (GPM)* Lbs/Kgs
47-0815-W0XX 115 50/60 10.0 1 6600/8000 90/32 2.0 160/73
47-0816-W0XX 115 60 10.0 1 8000 90/32 2.0 155/70
47-0825-W0XX 230 50 5.5 1 8000 90/32 2.0 155/70
47-0826-W0XX 230 60 5.0 1 8000 90/32 2.0 155/70
47-1215-W0XX 115 50/60 14.0 1 10000/12000 90/32 2.0 160/73
47-1216-W0XX 115 60 14.0 1 12000 90/32 2.0 155/70
47-1225-W0XX 230 50 7.0 1 12000 90/32 2.0 155/70
47-1226-W0XX 230 60 7.0 1 12000 90/32 2.0 155/70
-XX will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers.*Rated at 90°F inlet water and full air conditioning load. Actual usage will vary.Most models available with Hz selector switch, if desired. Contact factory.The 50/60 Hz units, because of the addition of an autotransformer, cost more that straight 60 Hz models. Units wired for 50 Hz operation when shipped. Asingle internal wiring change is required for 60 Hz operation.
WA
TE
R-C
OO
LE
D
McLEAN MIDWEST CLOSED-LOOP COOLING
Within the air conditioner, the recirculated clean enclosure air is kept
separate from the ambient airflow system. This protects the electronic
controls and prevents shutdowns caused by heat, humidity, dust and
other contaminants.
AIR
CO
ND
ITIO
NE
RS
33W
C,
47W
C,
LB
11W
C❑ Clean air flow
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz
CUT-OUT NOTES
1. Cord is routed
through the 2" x 11.13"
return air opening (top).
2. Dash lines
represent air
conditioner.
▲3. Bottom opening
will accommodate air
conditioner or heat
exchanger.
4. Cut-out dimensions
for standard product
only.33W
C S
ER
IES
47W
C S
ER
IES
LB
11W
C S
ER
IES
CUT-OUT NOTES
▲1. This cord hole may
be deleted if the service
cord is routed through
the 3" x 16.75" return
air opening.
2. Dash lines
represent air
conditioner.
▲3. This cut-out
accommodates units to
12000 BTU/Hr.
4. Cut-out dimensions
for standard product
only.
CUT-OUT NOTES
1. Dash lines represent
air conditioner.
2. Entire weight of air
conditioner is not
intended to be supported
by the mounting flanges.
Slide rails should be
installed.
3. Cut-out dimensions
for standard product
only.
SIDE MOUNT TO ENCLOSURE
For NEMA type 12 enclosure, interfacing air-out and
air-in openings are required in the enclosure wall.
SIDE MOUNT TO ENCLOSURE
For NEMA type 12 enclosure, interfacing air-out and
air-in openings are required in the enclosure wall.
RACK MOUNT TO ENCLOSURE
Unit may be rack mounted near the bottom of the
enclosure as shown, or use cut-out drawing for
NEMA type 12 enclosures.
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz
DESIGN NOTES
1. Gasket kit for
mounting to enclosure
included.
2. Service cord
terminated with
appropriate plug cap.
3. Condensate drain
hose included.
DESIGN NOTES
1. Gasket kit formounting to enclosureincluded.
2. Service cordterminated withappropriate plug cap.
3. Condensate drainhose included.
▲4. This 37.06" x 16.75"area is recessed 1.44"from rear surface(referred to as the “plenum”).
▲5. Cool air outletdimensions for 8000-12000 BTU/Hr units.
DESIGN NOTES
1. Gasket kit for
mounting to enclosure
included.
2. Service cord
terminated with
appropriate plug cap.
3. Condensate drain
hose included.
AIR
CO
ND
ITIO
NE
RS
33W
C,
47W
C,
LB
11W
CW
AT
ER
-CO
OL
ED
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz
FEATURES
• Stock models include thermostat control and EMI/RFI noise suppressor.
UL/CUL listing is standard on CR23, CR29 and CR43 stock models.
• The ProAir™ Series combines state-of-the-art design with pleasing aesthetics. This
highly efficient series offers a broad range of sizes and performance capacities.
• For more sophisticated requirements we offer Levels II and III Smart Control.
This microprocessor-based option provides programmable temperature
management, digital display of enclosure temperature, as well as remote
alarm capabilities.
• Maintenance is made easy by front cover hinging open for quick access to
all components.
• The Flip Filter design on the CR23 and CR29 uses only 50% of the filter surface
so filter can be inverted to double operating time between
cleanings/replacements.
• EZ Mount flanges simplify installation to a two-step, one-person job.
• Filterless operation possible in many applications.
• Unique condensate management system evaporates moisture from enclosure and
eliminates drain tubes, buckets and wet floors.
• High performance fans and blowers are ideal for densely packed enclosures.
• 100% functionally tested.
• Mounting hardware, gaskets, drawings, mounting template and instruction
manual furnished.
• All units use a CFC-free or environmentally safe refrigerant that is
universally accepted.
Most models available with UL and CUL listing. (UL File SA6453) CE available
upon request. Please contact the factory. NEMA 12 per UL 50 type 12 approval
on all models.
OTHER UNITS TO CONSIDER
CR23: CR23 Stainless Steel, pg. 36; Genesis™ 17, pg. 20
CR29: CR29 Stainless Steel, pg. 36; Genesis™ 28, pg. 24
CR43: CR43 Stainless Steel pg. 36
OPTIONS (SEE PGS. 80-81)
CR23 CR29 CR43
Smart Control Package ✔ ✔ ✔
Thermostat Package ✔ ✔ ✔
Thermostat/Malfunction Package ✔ ✔ ✔
Special Voltage Package ✔ ✔ ✔
Outdoor Package* ✔ ✔ ✔
Corrosive Environment Package* ✔ ✔ ✔
Stainless Steel Package SEE PAGES 36-39
Heater Package ✔ ✔ ✔
* Please refer to pgs. 36-39 for our air conditioners that have been engineered and manufacturedspecifically for demanding applications.
COMPACT TO FULL-SIZE Air Conditioners 1600-8500 BTU/HR.469-2490 WATTS
TM
CR43
CR29
CR23
The Ultimate Line
McLEAN MIDWEST CLOSED-LOOP COOLING
Within the air conditioner, the recirculated clean enclosure air is kept separate
from the ambient airflow system. This protects the electronic controls and
prevents shutdowns caused by heat, humidity, dust and other contaminants.
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz
CR231600 BTU/Hr. (469 Watts) H x W x D: 23" (584) x 10" (254) x 8.75" (222)
Max Shipping
BTU/Hr @ Amps @ BTU/Hr @ Amps @ Amb Temp Weight
Model Voltage Hz Phase 131°F/131°F* 131°F/131°F 95°F/95°F* 95°F/95°F °F/°C Lbs/Kgs
CR23-0216-G002 STOCK 115 50/60 1 1400/1600 4.1/4.5 1500/1700 3.8/3.6 131/55 57/26
CR23-0216-G0XX 115 50/60 1 1400/1600 4.1/4.5 1500/1700 3.8/3.6 131/55 57/26
CR23-0226-G002 STOCK 230 50/60 1 1400/1600 2.2/2.2 1500/1700 2.1/1.8 131/55 57/26
CR23-0226-G0XX 230 50/60 1 1400/1600 2.2/2.2 1500/1700 2.1/1.8 131/55 57/26
-XX will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers.*Two cooling capacities are listed to demonstrate the consistent performance throughout the typical operating range.
CR292000-4000 BTU/Hr. (586-1172 Watts) H x W x D: 29.50" (749) x 15.75" (400) x 8.63" (219)
Max Shipping
BTU/Hr @ Amps @ BTU/Hr @ Amps @ Amb Temp Weight
Model Voltage Hz Phase 131°F/131°F* 131°F/131°F 95°F/95°F* 95°F/95°F °F/°C Lbs/Kgs
CR29-0216-G002 STOCK 115 50/60 1 2000/2200 7.4/7.4 1700/2000 7.0/6.0 131/55 98/44
CR29-0216-G0XX 115 50/60 1 2000/2200 7.4/7.4 1700/2000 7.0/6.0 131/55 98/44
CR29-0226-G002 STOCK 230 50/60 1 2500/2700 4.6/3.9 1900/2300 4.4/3.3 131/55 98/44
CR29-0226-G0XX 230 50/60 1 2500/2700 4.6/3.9 1900/2300 4.4/3.3 131/55 98/44
CR29-0416-G002 STOCK 115 50/60 1 3500/4000 13.5/13.5 2400/2800 10.7/9.6 131/55 118/54
CR29-0416-G0XX 115 50/60 1 3500/4000 13.5/13.5 2400/2800 10.7/9.6 131/55 118/54
CR29-0426-G002 STOCK 230 50/60 1 3500/4000 6.7/6.6 2400/2800 5.9/5.3 131/55 118/54
CR29-0426-G0XX 230 50/60 1 3500/4000 6.7/6.6 2400/2800 5.9/5.3 131/55 118/54
-XX will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers.*Because air conditioners provide less cooling at lower operating temperatures, two cooling capacity ratings are listed for each ProAir™ air conditioner toassist you in your selection.
CR436000-8500 BTU/Hr. (1758-2490 Watts) H x W x D: 43.31" (1100) x 15.75" (400) x 10.25" (260)
Max Shipping
BTU/Hr @ Amps @ BTU/Hr @ Amps @ Amb Temp Weight
Model Voltage Hz Phase 131°F/131°F* 131°F/131°F 95°F/95°F* 95°F/95°F °F/°C Lbs/Kgs
CR43-0616-002 STOCK 115 60 1 6000 13.7 5100 11.0 131/55 133/60
CR43-0615-0XX 115 50/60 1 5800/6000 14.6/13.7 4800/5100 12.5/11.0 131/55 131/59
CR43-0616-0XX 115 60 1 6000 13.7 5100 11.0 131/55 131/59
CR43-0625-0XX 230 50 1 6000 6.8 5100 5.3 131/55 131/59
CR43-0626-002 STOCK 230 60 1 6000 6.9 5100 5.5 131/55 131/59
CR43-0626-0XX 230 60 1 6000 6.9 5100 5.5 131/55 131/59
CR43-0816-002 STOCK 115 60 1 8500 16.0 7500 12.9 131/55 140/64
CR43-0815-0XX 115 50/60 1 7500/8500 15.0/16.0 6700/7500 13.5/12.9 131/55 138/63
CR43-0816-0XX 115 60 1 8500 16.0 7500 12.9 131/55 138/63
CR43-0825-0XX 230 50 1 7500 8.0 7000 6.1 131/55 138/63
CR43-0826-002 STOCK 230 60 1 8500 8.2 7500 6.3 131/55 138/63
CR43-0826-0XX 230 60 1 8500 8.2 7500 6.3 131/55 138/63
-XX will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers.*Because air conditioners provide less cooling at lower operating temperatures, two cooling capacity ratings are listed for each ProAir™ air conditioner toassist you in your selection.
AIR
CO
ND
ITIO
NE
RS
CR
23,
CR
29,
CR
43
CR43
TM
TM
TM
TMCR29
CR23
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz
CUT-OUT NOTES
1. Dash lines represent
air conditioner.
2. Cut-out dimensions
for standard product
only.
3. Full-size mounting
template provided.
CR
23C
R29
CR
43
CUT-OUT NOTES
1. Dash lines represent
air conditioner.
2. Cut-out dimensions
for standard product
only.
3. Full-size mounting
template provided.
CUT-OUT NOTES
1. Dash lines represent
air conditioner.
2. Cut-out dimensions
for standard product
only.
3. Full-size mounting
template provided.
SIDE MOUNT TO ENCLOSURE
For NEMA type 12 enclosure, interfacing air-out and
air-in openings are required in the enclosure wall.
SIDE MOUNT TO ENCLOSURE
For NEMA type 12 enclosure, interfacing air-out and
air-in openings are required in the enclosure wall.
SIDE MOUNT TO ENCLOSURE
For NEMA type 12 enclosure, interfacing air-out and
air-in openings are required in the enclosure wall.
TMTM
TMOrder from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz
DESIGN NOTES
1. Gasket kit for
mounting to enclosure
included.
▲2. Service cord
terminated with
appropriate plug cap.
DESIGN NOTES
1. Gasket kit for
mounting to enclosure
included.
▲2. Service cord
terminated with
appropriate plug cap.
DESIGN NOTES
1. Gasket kit for
mounting to enclosure
included.
▲2. Service cord
terminated with
appropriate plug cap.
AIR
CO
ND
ITIO
NE
RS
CR
23,
CR
29,
CR
43
TM
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz
FEATURES
• Constructed of high-grade 16-gauge type 304 stainless steel for increased
protection in corrosive and outdoor applications.
• The Corrosive Environment and Outdoor Option Packages can be ordered
separately or together to provide optimum defense against especially harsh
conditions. The Corrosive Environment Package protects components exposed to
the corrosive environment on the ambient side of the air conditioner. The
Outdoor Package includes low temperature controls for operating down to -40°F.
• The ProAir™ Series combines state-of-the-art design with pleasing aesthetics. This
highly efficient series offers a broad range of sizes and performance capacities.
• For more sophisticated requirements we offer Levels II and III Smart Control. This
microprocessor-based option provides programmable temperature management,
digital display of enclosure temperature, as well as remote alarm capabilities.
• Maintenance is made easy by front cover hinging open for quick access to
all components.
• The Flip Filter design on the CR23 and CR29 uses only 50% of the filter surface so
filter can be inverted to double operating time between cleanings/replacements.
• EZ Mount flanges simplify installation to a two-step, one-person job.
• Filterless operation possible in many applications.
• Unique condensate management system evaporates moisture from enclosure and
eliminates drain tubes, buckets and wet floors.
• High performance fans and blowers are ideal for densely packed enclosures.
• 100% functionally tested.
• Mounting hardware, gaskets, drawings, mounting template and instruction
manual furnished.
• All units use a CFC-free or environmentally safe refrigerant that is
universally accepted.
Most models available with UL and CUL listing. CE available upon request.
Please contact the factory. (UL File SA6453) NEMA 12 per UL 50 Type 12 approval
on all models. NEMA 4X per UL 50 Type 4X optional.
OTHER UNITS TO CONSIDER
CR23 Stainless Steel: CR23, pg. 16; Genesis™ 17, pg. 20
CR29 Stainless Steel: CR29, pg. 16; Genesis™ 28, pg. 24
CR43 Stainless Steel: CR43, pg. 16
OPTIONS (SEE PGS. 80-81)
CR23 CR29 CR43
Smart Control Package ✔ ✔ ✔
Thermostat Package ✔ ✔ ✔
Thermostat/Malfunction Package ✔ ✔ ✔
Special Voltage Package ✔ ✔ ✔
Outdoor Package* ✔ ✔ ✔
Corrosive Environment Package* ✔ ✔ ✔
Heater Package ✔ ✔ ✔NEMA 4X Package (see note on pg. 37) ✔ ✔ ✔
* Must be ordered separately to achieve desired protection.
OUTDOOR/CORROSIVE/STAINLESS STEEL 1600-8500 BTU/HR.469-2490 WATTS
TM
CR43CR29 CR23
The Ultimate Protection
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz
CR43
TM
TM TM
Stainless Steel CR231600 BTU/Hr. (469 Watts) H x W x D: 23" (584) x 10" (254) x 8.75" (222)
Max Shipping
BTU/Hr @ Amps @ BTU/Hr @ Amps @ Amb Temp Weight
Model Voltage Hz Phase 131°F/131°F* 131°F/131°F 95°F/95°F* 95°F/95°F °F/°C Lbs/Kgs
CR23-0216-G0ST 115 50/60 1 1400/1600 4.1/4.5 1500/1700 3.8/3.6 131/55 57/26
CR23-0226-G0ST 230 50/60 1 1400/1600 2.2/2.2 1500/1700 2.1/1.8 131/55 57/26
-0ST will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers.* Two cooling capacities are listed to demonstrate the consistent performance throughout the typical operating range.
Stainless Steel CR292000-4000 BTU/Hr. (586-1172 Watts) H x W x D: 29.50" (749) x 15.75" (400) x 8.63" (219)
Max Shipping
BTU/Hr @ Amps @ BTU/Hr @ Amps @ Amb Temp Weight
Model Voltage Hz Phase 131°F/131°F* 131°F/131°F 95°F/95°F* 95°F/95°F °F/°C Lbs/Kgs
CR29-0216-G0ST 115 50/60 1 2000/2200 7.4/7.4 1700/2000 7.0/6.0 131/55 98/44
CR29-0226-G0ST 230 50/60 1 2500/2700 4.6/3.9 1900/2300 4.4/3.3 131/55 98/44
CR29-0416-G0ST 115 50/60 1 3500/4000 13.5/13.5 2400/2800 10.7/9.6 131/55 118/54
CR29-0426-G0ST 230 50/60 1 3500/4000 6.7/6.6 2400/2800 5.9/5.3 131/55 118/54
-0ST will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers.*Because air conditioners provide less cooling at lower operating temperatures, two cooling capacity ratings are listed for each ProAir™ air conditioner toassist you in your selection.
Stainless Steel CR436000-8500 BTU/Hr. (1758-2490 Watts) H x W x D: 43.31" (1100) x 15.75" (400) x 10.25" (260)
Max Shipping
BTU/Hr @ Amps @ BTU/Hr @ Amps @ Amb Temp Weight
Model Voltage Hz Phase 131°F/131°F* 131°F/131°F 95°F/95°F* 95°F/95°F °F/°C Lbs/Kgs
CR43-0615-0ST 115 50/60 1 5800/6000 14.6/13.7 4800/5100 12.5/11.0 131/55 131/59
CR43-0616-0ST 115 60 1 6000 13.7 5100 11.0 131/55 131/59
CR43-0625-0ST 230 50 1 6000 6.8 5100 5.3 131/55 131/59
CR43-0626-0ST 230 60 1 6000 6.9 5100 5.5 131/55 131/59
CR43-0815-0ST 115 50/60 1 7500/8500 15.0/16.0 6700/7500 13.5/12.9 131/55 138/63
CR43-0816-0ST 115 60 1 8500 16.0 7500 12.9 131/55 138/63
CR43-0825-0ST 230 50 1 7500 8.0 7000 6.1 131/55 138/63
CR43-0826-0ST 230 60 1 8500 8.2 7500 6.3 131/55 138/63
-0ST will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers.*Because air conditioners provide less cooling at lower operating temperatures, two cooling capacity ratings are listed for each ProAir™ air conditioner toassist you in your selection.
McLEAN MIDWEST CLOSED-LOOP COOLING
Within the air conditioner, the recirculated clean enclosure air is kept separate
from the ambient airflow system. This protects the electronic controls and
prevents shutdowns caused by heat, humidity, dust and other contaminants.
OU
TD
OO
R/C
ORR
OSI
VE/
STA
INLE
SS S
TEE
LC
R23,
CR
29,
CR
43
TM
TM
TM
NEMA 4X
The protective shields illustrated
here are required to achieve NEMA
4X. Shield protrudes approximately
2" from the air conditioner. Contact
factory for details.
CR23
CR29
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz
CUT-OUT NOTES
1. Dash lines represent
air conditioner.
2. Cut-out dimensions
for standard product
only.
3. Full-size mounting
template provided.
Stai
nles
s St
eel C
R23
CUT-OUT NOTES
1. Dash lines represent
air conditioner.
2. Cut-out dimensions
for standard product
only.
3. Full-size mounting
template provided.
CUT-OUT NOTES
1. Dash lines represent
air conditioner.
2. Cut-out dimensions
for standard product
only.
3. Full-size mounting
template provided.
SIDE MOUNT TO ENCLOSURE
For NEMA type 12 enclosure, interfacing air-out and
air-in openings are required in the enclosure wall.
SIDE MOUNT TO ENCLOSURE
For NEMA type 12 enclosure, interfacing air-out and
air-in openings are required in the enclosure wall.
SIDE MOUNT TO ENCLOSURE
For NEMA type 12 enclosure, interfacing air-out and
air-in openings are required in the enclosure wall.
TMSt
ainl
ess
Stee
l CR
29TM
Stai
nles
s St
eel C
R43
TMOrder from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz
DESIGN NOTES
1. Gasket kit for
mounting to enclosure
included.
▲2. Service cord
terminated with
appropriate plug cap.
▲4. Dashed lines
indicate optional shroud
used, along with other
special construction
features, for NEMA 4X.
Please contact factory
for details.
DESIGN NOTES
1. Gasket kit for
mounting to enclosure
included.
▲2. Service cord
terminated with
appropriate plug cap.
▲4. Dashed lines
indicate optional shroud
used, along with other
special construction
features, for NEMA 4X.
Please contact factory
for details.
DESIGN NOTES
1. Gasket kit for
mounting to enclosure
included.
▲2. Service cord
terminated with
appropriate plug cap.
▲4. Dashed lines
indicate optional shroud
used, along with other
special construction
features, for NEMA 4X.
Please contact factory
for details.
OU
TD
OO
R/C
ORR
OSI
VE/
STA
INLE
SS S
TEE
LC
R23,
CR
29,
CR
43
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz
FEATURES
• Stock models are equipped with a thermostat control that offers convenient digital
display of enclosure temperature and high temperature alarm (125ºF/52ºC). Flashing
display indicates alarm condition. EMI/RFI noise suppressor and UL/CUL and CE listing
are standard on stock models.
• New Genesis™ 33NSM and 36N models offer: improved aesthetics with no changes
to the major internal components so airflow and performance are the same as the
corresponding Slimboy models; unique condensate management system evaporates
moisture from enclosure and eliminates drain tubes, buckets and wet floors in typical
applications; and EZ Mount flanges simplify installation to a two-step, one-person job.
• Genesis™ units are directly interchangeable with the comparable Slimboy Series,
however, the Genesis 33NSM does not come equipped with a backplane like the old
Slimboy model.
• Narrow models offer a broad capacity range with the advantage of mounting on
narrow enclosures. The 33NSM Series is only 12" wide, and the 36N and 47N Series
are only 15" wide.
• High performance, industrial-grade ball bearing fans in the 33NSM, and high
performance blowers in the 36N and 47N, provide maximum heat transfer in densely
packed enclosures.
• Most components accessible by removing air filter.
• 100% functionally tested.
• Mounting gaskets, drawings and instruction manual furnished.
• All units use a CFC-free or environmentally safe refrigerant that is
universally accepted.
UL/CUL listing and CE standard on all Genesis™ 33NSM and 36N models.
(UL File SA6453) Please contact the factory. NEMA 12 per UL 50 type 12
approval on all models.
OTHER UNITS TO CONSIDER
Genesis™ 33NSM: 33 Water-Cooled, pg. 40
47N Series: 47 Water-Cooled, pg. 40
OPTIONS (SEE PGS. 80-81)
33NSM 36N 47N
Thermostat Package ✔ ✔ ✔
Thermostat/Malfunction Package ✔ ✔ ✔
Condensate Evaporator Package ** ** ✔
Special Voltage Package ✔ ✔ ✔
Outdoor Package* ✔ ✔ ✔
Corrosive Environment Package* ✔ ✔ ✔
Stainless Steel Package* ✔ ✔ ✔
Heater Package ✔ ✔ ✔
* Please refer to pgs. 36-39 for our air conditioners that have been engineered and manufacturedspecifically for demanding applications.
** A condensate management system is standard. See features.
NARROW Air Conditioners 4000-10000 BTU/HR.1172-2930 WATTS
47N
33NSM36N
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz
47N
GENESIS™ 33NSM Series4000 BTU/Hr. (1172 Watts) H x W x D: 34.37" (873) x 12" (305) x 9.88" (251)
Full BTU/Hr @ Max Shipping
Load Max Amb Amb Temp Weight
Model Voltage Hz Amps Phase Temp °F/°C Lbs/Kgs
M33-0416-G010 STOCK 115 50/60 13.0/13.2 1 3700/4000 125/52 105/48
M33-0416-G0XX 115 50/60 13.0/13.2 1 3700/4000 125/52 105/48
M33-0426-G009 STOCK 230 50/60 7.2/7.3 1 3700/4000 125/52 105/48
M33-0426-G0XX 230 50/60 7.2/7.3 1 3700/4000 125/52 105/48
-XX will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers.An “M” in the model number identifies the new Genesis™ Series of air conditioners.
GENESIS™ 36N Series6000 BTU/Hr. (1758 Watts) H x W x D: 38.72" (984) x 15" (381) x 11.33" (288)
Full BTU/Hr @ Max Shipping
Load Max Amb Amb Temp Weight
Model Voltage Hz Amps Phase Temp °F/°C Lbs/Kgs
M36-0616-307 STOCK 115 50/60 14.0/14.0 1 5000/6000 125/52 120/54
M36-0616-3XX 115 50/60 14.0/14.0 1 5000/6000 125/52 120/54
M36-0626-306 STOCK 230 50/60 7.0/7.0 1 5000/6000 125/52 120/54
M36-0626-3XX 230 50/60 7.0/7.0 1 5000/6000 125/52 120/54
-XX will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers.An “M” in the model number identifies the new Genesis™ Series of air conditioners.
47N Series8000-10000 BTU/Hr. (2344-2930 Watts) H x W x D: 49.13" (1248) x 15" (381) x 10.50" (267)
Full BTU/Hr @ Max Shipping
Load Max Amb Amb Temp Weight
Model Voltage Hz Amps Phase Temp °F/°C Lbs/Kgs
47-0815-3XX 115 50/60 18.0 1 6700/8000 125/52 150/68
47-0816-3XX 115 60 18.0 1 8000 125/52 150/68
47-0825-3XX 230 50 9.0 1 8000 125/52 150/68
47-0826-3XX 230 60 9.0 1 8000 125/52 150/68
47-1015-3XX 115 50/60 18.0 1 8300/10000 125/52 155/70
47-1016-3XX 115 60 18.0 1 10000 125/52 155/70
47-1025-3XX 230 50 10.0 1 10000 125/52 155/70
47-1026-3XX 230 60 9.0 1 10000 125/52 155/70
-XX will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers.Most models available with Hz selector switch, if desired. Contact factory.The 50/60 Hz units, because of the addition of an autotransformer, cost more than straight 60 Hz models. Units wired for 50 Hz operation when shipped. Asingle internal wiring change is required for 60 Hz operation.
AIR
CO
ND
ITIO
NE
RS
33N
SM
, 36N
, 47N
NA
RR
OWMcLEAN MIDWEST CLOSED-LOOP COOLING
Within the air conditioner, the recirculated clean enclosure air is kept separate
from the ambient airflow system. This protects the electronic controls and
prevents shutdowns caused by heat, humidity, dust and other contaminants.
33NSM
36N
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz
CUT-OUT NOTES
1. Cord is routed
through the 2" x 11.12"
return air opening (top).
2. Dash lines represent
air conditioner.
3. Cut-out dimensions
for standard product
only.
▲4. Bottom opening
will accommodate air
conditioner or heat
exchanger.
5. Full-size mounting
template provided.GEN
ESIS
™33
NSM
Ser
ies
GEN
ESIS
™36
N S
erie
s47
N S
erie
s
CUT-OUT NOTES
1. Service cord is
routed through the 3" x
14" return air opening.
2. Dash lines represent
air conditioner.
3. Cut-out dimensions
for standard product
only.
4. Full-size mounting
template provided.
CUT-OUT NOTES
1. Dash lines represent
air conditioner.
2. Cut-out dimensions
for standard product
only.
SIDE MOUNT TO ENCLOSURE
For NEMA type 12 enclosure, interfacing air-out and
air-in openings are required in the enclosure wall.
SIDE MOUNT TO ENCLOSURE
For NEMA type 12 enclosure, interfacing air-out and
air-in openings are required in the enclosure wall.
SIDE MOUNT TO ENCLOSURE
For NEMA type 12 enclosure, interfacing air-out and
air-in openings are required in the enclosure wall.
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz
DESIGN NOTES
1. Gasket kit for
mounting to enclosure
included.
▲2. Service cord.
▲3. This 25.58" x 11"
area is recessed 1.12"
from rear surface
(referred to as the
“plenum”).
▲5. Condenser air
discharge out front is
optional.
DESIGN NOTES
1. Gasket kit for
mounting to enclosure
included.
▲2. Service cord.
▲3. This 14" x 29.13"
area is recessed 1.44"
from rear surface
(referred to as the
“plenum”).
▲4. Condenser air
discharge out front is
optional.
DESIGN NOTES
1. Gasket kit for
mounting to enclosure
included.
2. Service cord
terminated with
appropriate plug cap.
▲3. This 36.13" x 14"
area is recessed 1.63"
from rear surface
(referred to as the
“plenum”).
NA
RR
OW
AIR
CO
ND
ITIO
NE
RS
33N
SM
, 36N
, 47N
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz
FEATURES
• Genesis™ 28 stock models are equipped with a thermostat control that offers
convenient digital display of enclosure temperature and high temperature alarm
(125ºF/52ºC). Flashing display indicates alarm condition. 36 Series stock models
have an electro-mechanical thermostat. Genesis™ 28 stock models are UL/CUL
and CE standard. Both Series include EMI/RFI noise suppressor on stock models.
• New Genesis™ 28 models offer: improved aesthetics with no changes to the
major internal components so airflow and performance are the same as the
corresponding Slimboy models; unique condensate management system
evaporates moisture from enclosure and eliminates drain tubes, buckets and wet
floors in typical applications; and EZ Mount flanges simplify installation to a two-
step, one-person job.
• Genesis™ units are directly interchangeable with the comparable Slimboy Series.
A field retrofit plate is needed only when mounting the Genesis™ 28 to an old
Slimboy model cutout. Plate is free upon request. For Slimboy 28 models with
side mounting rails, field retrofit plate part number is 28-plate. For other
mounting configurations, contact the factory.
• The Mid-Size models offer universal sizes and a broad performance range making
them some of the most popular in the industry.
• High CFM ball-bearing centrifugal blowers are ideal for densely packaged enclosures.
• Most components accessible by removing air filter.
• 100% functionally tested.
• Mounting gaskets, drawings and instruction manual furnished.
• All units use a CFC-free or environmentally safe refrigerant that is
universally accepted.
UL/CUL listing and CE standard on all Genesis™ 28 models. Certain 36 models
available with UL listing. (UL File SA6453). Please contact the factory.
NEMA 12 per UL 50 type 12 approval on all models.
OTHER UNITS TO CONSIDER
Genesis™ 28: CR29, pg. 16; CR29 Stainless Steel, pg. 36
36 Series: Genesis™ 36N, pg. 32
OPTIONS (SEE PGS. 80-81)
28 36
Thermostat Package ✔ ✔
Thermostat/Malfunction Package ✔ ✔
Condensate Evaporator Package ** ✔
Special Voltage Package ✔ ✔
Outdoor Package* ✔ ✔
Heater Package ✔ ✔
Corrosive Environment Package* ✔ ✔
Stainless Steel Package* ✔ ✔
* Please refer to pgs. 36-39 for our air conditioners that have been engineered and manufacturedspecifically for demanding applications.
** A condensate management system is standard. See features.
MID-SIZE Air Conditioners 2000-6000 BTU/HR.586-1758 WATTS
36
28
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz
36 Series6000 BTU/Hr. (1758 Watts) H x W x D: 36.69" (932) x 19" (483) x 10.88" (276)
Full BTU/Hr @ Max Shipping
Load Max Amb Amb Temp Weight
Model Voltage Hz Amps Phase Temp °F/°C Lbs/Kgs
36-0616-136 STOCK 115 60 14.0 1 6000 125/52 129/59
36-0615-1XX 115 50/60 14.0 1 5000/6000 125/52 131/59
36-0616-1XX 115 60 14.0 1 6000 125/52 126/57
36-0625-1XX 230 50 7.0 1 6000 125/52 126/57
36-0626-113 STOCK 230 60 7.0 1 6000 125/52 126/57
36-0626-1XX 230 60 7.0 1 6000 125/52 126/57
-XX will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers.Most models available with Hz selector switch, if desired. Contact factory.The 50/60 Hz units, because of the addition of an autotransformer, cost more than straight 60 Hz models. Units wired for 50 Hz operation when shipped. Asingle internal wiring change is required for 60 Hz operation.
McLEAN MIDWEST CLOSED-LOOP COOLING
Within the air conditioner, the
recirculated clean enclosure air is kept
separate from the ambient airflow
system. This protects the electronic
controls and prevents shutdowns caused
by heat, humidity, dust and other
contaminants.
3628
GENESIS™ 28 Series2000-6000 BTU/Hr. (586-1758 Watts) H x W x D: 28.50" (724) x 17" (432) x 11.33" (288)
Full BTU/Hr @ Max Shipping
Load Max Amb Amb Temp Weight
Model Voltage Hz Amps Phase Temp °F/°C Lbs/Kgs
M28-0216-G013 STOCK 115 50/60 9.8/9.0 1 2200/2200 125/52 98/45
M28-0216-G0XX 115 50/60 9.8/9.0 1 2200/2200 125/52 98/45
M28-0226-G004 STOCK 230 50/60 5.0/4.5 1 2200/2200 125/52 98/45
M28-0226-G0XX 230 50/60 5.0/4.5 1 2200/2200 125/52 98/45
M28-0416-G007 STOCK 115 50/60 14.6/14.0 1 3800/4000 125/52 116/53
M28-0416-G0XX 115 50/60 14.6/14.0 1 3800/4000 125/52 116/53
M28-0426-G032 STOCK 230 50/60 7.4/6.9 1 3800/4000 125/52 116/53
M28-0426-G0XX 230 50/60 7.4/6.9 1 3800/4000 125/52 116/53
M28-0616-0XX 115 50/60 15.0/15.0 1 5400/6000 125/52 120/55
M28-0626-0XX 230 50/60 7.3/7.3 1 5400/6000 125/52 120/55
-XX will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers.An “M” in the model number identifies the new Genesis™ Series of air conditioners.
MID
-SIZ
EA
IR C
ON
DIT
ION
ER
S28,
36
❑ Ambient air flow❑ Clean air flow
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz
GENESIS™ 28 Series
CUT-OUT NOTES
1. Dash lines represent
air conditioner.
2. Cut-out dimensions
for standard product
only.
▲3. This hole may be
deleted if the service
cord is routed through
the 3" x 13.50" return
air opening.
4. Full-size mounting
template provided.
DESIGN NOTES
1. Gasket kit for mounting to enclosure included.
▲2. Service cord.
▲4. This 20.50" x 15.50" area is recessed 1.00" from rear surface (referred to as the “plenum”).
▲5. Condenser air discharge out front is optional.
SIDE MOUNT TO ENCLOSURE
For NEMA type 12 enclosure, interfacing air-out and
air-in openings are required in the enclosure wall.
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz
36 Series
CUT-OUT NOTES
▲1. This cord hole may
be deleted if the service
cord is routed through
the 3" x 16.75" return
air opening.
2. Dash lines represent
air conditioner.
3. Cut-out dimensions
for standard product
only.
DESIGN NOTES
1. Gasket kit for mounting to enclosure included.
2. Service cord terminated with appropriate plug cap.
▲3. This 30.06" x 16.75" area is recessed .94" from rear surface (referred to as the “plenum”).
SIDE MOUNT TO ENCLOSURE
For NEMA type 12 enclosure, interfacing air-
out and air-in openings are required in the
enclosure wall.
MID
-SIZ
EA
IR C
ON
DIT
ION
ER
S28,
36
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz
FEATURES
• Stock models are equipped with a thermostat control that offers convenient
digital display of enclosure temperature and high temperature alarm (125ºF/52ºC).
Flashing display indicates alarm condition. EMI/RFI noise suppressor and UL/CUL
and CE are standard on stock models of 6,000 and 8,000 BTU/Hr. models. On
10,000 and 12,000 BTU/Hr. models of the Genesis 52 Series, the 115 volt stock
model is UR/CUR recognized.
• New Genesis™ 52 models offer: improved aesthetics with no changes to the
major internal components so airflow and performance are the same as the
corresponding Slimboy models; unique condensate management system
evaporates moisture from enclosure and eliminates drain tubes, buckets and wet
floors in typical applications; and EZ Mount flanges simplify installation to a two-
step, one-person job.
• Genesis™ units are directly interchangeable with the comparable Slimboy Series.
A field retrofit plate is needed only when mounting the Genesis™ 52 to an old
Slimboy model cutout. Plate is free upon request. For Slimboy 52 models with
side mounting rails, field retrofit plate part number is 52-plate. For other
mounting configurations, contact the factory.
• Full-Size models offer the highest cooling capacities in McLean's extensive air
conditioner range.
• McLean’s highest performance CFM ball-bearing centrifugal blowers are ideal for
densely packed enclosures.
• Most components accessible by removing air filter.
• 100% functionally tested.
• Mounting gaskets, drawings and instruction manual furnished.
• All units use a CFC-free or environmentally safe refrigerant that is
universally accepted.
UL/CUL listing and CE standard on most Genesis™ 52 models, except the 115 volt,
Genesis 52 series in the 10,000 and 12,000 BTU/Hr. which are UR/CUR
recognized. Certain 52HC models available with UL listing. (UL File SA6453)
Please contact the factory. NEMA 12 per UL 50 type 12 approval on all models.
OPTIONS (SEE PGS. 80-81)
52 52HC
Thermostat Package ✔ ✔
Thermostat/Malfunction Package ✔ ✔
Condensate Evaporator Package ** ✔
Special Voltage Package ✔ ✔
Outdoor Package* ✔ ✔
Corrosive Environment Package* ✔ ✔
Stainless Steel Package* ✔ ✔
Heater Package ✔ ✔
* Please refer to pgs. 36-39 for our air conditioners that have been engineered and manufacturedspecifically for demanding applications.
** A condensate management system is standard. See features.
FULL-SIZE Air Conditioners 6000-20000 BTU/HR.1758-5860 WATTS
52HC52
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz
52HC Series14000-20000 BTU/Hr. (4100-5860 Watts) H x W x D: 52.50" (1333) x 23" (584) x 12.88" (327)
Full BTU/Hr @ Max Shipping
Load Max Amb Amb Temp Weight
Model Voltage Hz Amps Phase Temp °F/°C Lbs/Kgs
52-1425-0XX 230 50 14.0 1 14000 125/52 220/100
52-1426-0XX 230 60 14.0 1 14000 125/52 220/100
52-1625-0XX 230 50 16.0 1 16000 125/52 225/102
52-1626-0XX 230 60 17.0 1 16000 125/52 225/102
52-1926-0XX 230 50/60 18.8/18.8 1 17500/20000 125/52 235/107
-XX will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers.
McLEAN MIDWEST
CLOSED-LOOP COOLING
Within the air conditioner, the recirculated clean
enclosure air is kept separate from the ambient
airflow system. This protects the electronic
controls and prevents shutdowns caused by heat,
humidity, dust and other contaminants.
GENESIS™ 52 Series6000-12000 BTU/Hr. (1758-3516 Watts) H x W x D: 52.63" (1337) x 17.13" (435) x 11.33" (288)
Full BTU/Hr @ Max Shipping
Load Max Amb Amb Temp Weight
Model Voltage Hz Amps Phase Temp °F/°C Lbs/Kgs
M52-0616-0XX 115 50/60 13.0/13.0 1 5000/6000 125/52 155/70
M52-0626-0XX 230 50/60 6.5/6.5 1 5000/6000 125/52 155/70
M52-0816-032 STOCK 115 50/60 14.5/14.5 1 6700/8000 125/52 160/73
M52-0816-0XX 115 50/60 14.5/14.5 1 6700/8000 125/52 160/73
M52-0826-015 STOCK 230 50/60 8.0/8.0 1 6700/8000 125/52 160/73
M52-0826-0XX 230 50/60 8.0/8.0 1 6700/8000 125/52 160/73
M52-1016-038 STOCK 110/115 50/60 18.9/19.5 1 8300/10000 125/52 165/75
M52-1016-0XX 110/115 50/60 18.9/19.5 1 8300/10000 125/52 165/75
M52-1026-021 STOCK 220/230 50/60 9.5/9.8 1 8300/10000 125/52 165/75
M52-1026-0XX 220/230 50/60 9.5/9.8 1 8300/10000 125/52 165/75
M52-1216-017 STOCK 110/115 50/60 24.0/23.0 1 10000/12000* 125/52 175/79
M52-1216-0XX 110/115 50/60 24.0/23.0 1 10000/12000* 125/52 175/79
M52-1226-034 STOCK 220/230 50/60 12.0/11.6 1 10000/12000* 125/52 175/79
M52-1226-0XX 220/230 50/60 12.0/11.6 1 10000/12000* 125/52 175/79
-XX will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers.Most models available with Hz selector, if desired. Contact factory.The 50/60 Hz units, because of the addition of an autotransformer, cost more than straight 60 Hz models. Units wired for 50 Hz operation when shipped. Asingle internal wiring change is required for 60 Hz operation.* Based on return air temperature slightly above ambient.An “M” in the model number identifies the new Genesis™ Series of air conditioners.
FU
LL
-SIZ
EA
IR C
ON
DIT
ION
ER
S52,
52H
C
❑ Ambient air flow❑ Clean air flow
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz
GENESIS™ 52 Series
CUT-OUT NOTES
1. Dash lines represent
air conditioner.
2. Cut-out dimensions
for standard product
only.
▲3. This cord hole may
be deleted if the service
cord is routed through
the 4.50" x 15.63" return
air opening (except units
with electric heat).
4. Full-size mounting
template provided.
DESIGN NOTES
1. Gasket kit for mounting to enclosure included.
▲2. Service cord.
▲3. This 42.06" x 15.63" area is recessed 1.44" from rear surface (referred to as the “plenum”).
▲4. Condenser air discharge out front is optional.
SIDE MOUNT TO ENCLOSURE
For NEMA type 12 enclosure, interfacing air-out and
air-in openings are required in the enclosure wall.
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz
52HC Series
CUT-OUT NOTES
1. Dash lines represent
air conditioner.
2. Cut-out dimensions
for standard product
only.
DESIGN NOTES
1. Gasket kit for mounting to enclosure included.
▲2. This 47" x 20.88" area is recessed 1.69" from rear surface (referred to as the “plenum”).
3. Service cord terminated with appropriate plug cap.
* Dimensional changes required to accommodate autotransformer on 50/60 Hz units.
SIDE MOUNT TO ENCLOSURE
For NEMA type 12 enclosure, interfacing air-
out and air-in openings are required in the
enclosure wall. Refer to mounting dimensions.
FU
LL
-SIZ
EA
IR C
ON
DIT
ION
ER
S52,
52H
C
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz
1713
FEATURES
• Stock models are equipped with a thermostat control that offers convenientdigital display of enclosure temperature and high temperature alarm (125ºF/52ºC).Flashing display indicates alarm condition. EMI/RFI noise suppressor and UL/CULand CE are standard on stock models.
• New Genesis™ models offer improved aesthetics with no changes to the majorinternal components so airflow and performance are the same as thecorresponding Slimboy models.
• Genesis™ units are directly interchangeable with the comparable Slimboy Series.
• Unique condensate management system evaporates moisture from enclosure andeliminates drain tubes, buckets and wet floors in typical applications.
• Compact models are ideal for cooling smaller enclosures from 25 cu. ft. to 40 cu.ft. The ultra-narrow 17 Series is only 12" wide making it perfect for enclosureswith narrow side walls.
• EZ Mount flanges simplify installation to a two-step, one-person job.
• High-performance, industrial-grade ball-bearing fans used to provide maximumheat transfer.
• Most components accessible by removing grille/filter.
• 100% functionally tested.
• Mounting hardware, gaskets, drawings, mounting template and instruction manualfurnished.
• All units use a CFC-free or environmentally safe refrigerant that is universally accepted.
UL/CUL listing and CE standard on all models. (UL File SA6453).
Please contact the factory. NEMA 12 per UL 50 type 12 approval on all models.
OTHER UNITS TO CONSIDER
Genesis™ 17: CR23, pg. 16; CR23 Stainless Steel, pg. 36
OPTIONS (SEE PGS. 80-81)
13 17
Thermostat Package ✔ ✔
Thermostat/Malfunction Package ✔ ✔
Special Voltage Package ✔ ✔
Outdoor Package* ✔ ✔
Corrosive Environment Package* ✔ ✔
Stainless Steel Package* ✔ ✔
* Please refer to pgs. 36-39 for our air conditioners that have been engineered and manufacturedspecifically for demanding applications.
COMPACT Air Conditioners 1000-1800 BTU/HR.293-527 WATTS
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz
McLEAN MIDWEST CLOSED-LOOP COOLING
Within the air conditioner, the recirculated clean enclosure air is kept separate
from the ambient airflow system. This protects the electronic controls and
prevents shutdowns caused by heat, humidity, dust and other contaminants.
AIR
CO
ND
ITIO
NE
RS
13,
17
1713
GENESIS™ 13 Series1000 BTU/Hr. (293 Watts) H x W x D: 13.25" (337) x 14.25" (362) x 7.80" (198)
Full BTU/Hr @ Max Shipping
Load Max Amb Amb Temp Weight
Model Voltage Hz Amps Phase Temp °F/°C Lbs/Kgs
M13-0116-G1014 STOCK 115 50/60 4.0/4.0 1 800/1000 125/52 48/22
M13-0116-G1XXX 115 50/60 4.0/4.0 1 800/1000 125/52 48/22
M13-0126-G1008 STOCK 230 50/60 2.2/2.1 1 800/1000 125/52 48/22
M13-0126-G1XXX 230 50/60 2.2/2.1 1 800/1000 125/52 48/22
-XXX will be replaced with a three-digit number designating all desired options. Consult the factory for specific model numbers.An “M” in the model number identifies the new Genesis™ Series of air conditioners.
GENESIS™ 17 Series1800 BTU/Hr. (527 Watts) H x W x D: 17.65" (448) x 12" (305) x 8.68" (220)
Full BTU/Hr @ Max Shipping
Load Max Amb Amb Temp Weight
Model Voltage Hz Amps Phase Temp °F/°C Lbs/Kgs
M17-0216-G009 STOCK 110/115 50/60 6.6/6.7 1 1500/1800 125/52 56/25
M17-0216-G0XX 110/115 50/60 6.6/6.7 1 1500/1800 125/52 56/25
M17-0226-G004 STOCK 220/230 50/60 4.2/3.7 1 1500/1800 125/52 56/25
M17-0226-G0XX 220/230 50/60 4.2/3.7 1 1500/1800 125/52 56/25
-XX will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers.An "M" in the model number identifies the new Genesis™ Series of air conditioners.
CO
MPA
CT
❑ Ambient air flow❑ Clean air flow
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz
GENESIS™ 13 Series
CUT-OUT NOTES
1. Dash lines represent
air conditioner.
2. Cut-out dimensions
for standard product
only.
3. Full-size mounting
template provided.
DESIGN NOTES
1. Gasket kit for mounting to enclosure included.
▲2. Service cord.
SIDE MOUNT TO ENCLOSURE
For NEMA type 12 enclosure, interfacing air-out and
air-in openings are required in the enclosure wall.
Generally, the 13 Series is most effective on
enclosures up to 25 cu. ft., unless the application is
only for spot cooling in a larger enclosure.
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz
GENESIS™ 17 Series
CUT-OUT NOTES
1. Dash lines represent
air conditioner.
2. Cut-out dimensions
for standard product
only.
3. Full-size mounting
template provided.
DESIGN NOTES
1. Gasket kit for mounting to enclosure included.
▲2. Service cord.
3. Condensate from enclosure drains to bottom pan of unit where it is evaporated by condenser heat.
SIDE MOUNT TO ENCLOSURE
For NEMA type 12 enclosure, interfacing air-
out and air-in openings are required in the
enclosure wall. Generally, the 17 Series is
most effective on enclosures up to 40 cu. ft.,
unless the application is only for spot cooling
in a larger enclosure.
CO
MPA
CT
A
IR C
ON
DIT
ION
ER
S13,
17
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz
HB11
FEATURES
• Stock HB11 models are equipped with a thermostat control that offers
convenient digital display of enclosure temperature and high temperature alarm
(125ºF/52ºC). Flashing display indicates alarm condition. EMI/RFI noise suppressor
and UR/CUR and CE are standard on stock models.
• New Genesis™ HB11 models offer: improved aesthetics with no changes to the
major internal components so airflow and performance are the same as the
corresponding Slimboy model.
• Genesis™ units are directly interchangeable with the comparable Slimboy Series.
• HB11 and HB30 models have a unique condensate management system that
evaporates moisture from enclosure and eliminates drain tubes, buckets and wet
floors in typical applications.
• Top-Mount air conditioners are ideal for use where there is little or no clearance
around the enclosure.
• High CFM ball-bearing centrifugal blowers are ideal for densely packaged enclosures.
• 100% functionally tested.
• Mounting gaskets, drawings and instruction manual furnished.
• All units use a CFC-free or environmentally safe refrigerant that is
universally accepted.
UL recognized, CUL recognized and CE standard on all Genesis™ HB11 models.
Certain HB16 models available with UL listing. (UL File SA6453) Please contact the
factory. NEMA 12 per UL 50 type 12 approval on all models.
OPTIONS (SEE PGS. 80-81)
HB11 HB16 HB30
Thermostat Package ✔ ✔ ✔
Thermostat/Malfunction Package ✔ ✔ ✔
Special Voltage Package ✔ ✔ ✔
Corrosive Environment Package* ✔ ✔ ✔
Stainless Steel Package* ✔ ✔ ✔
Heater Package ✔ ✔ ✔
* Please refer to pgs. 36-39 for our air conditioners that have been engineered and manufacturedspecifically for demanding applications.
TOP-MOUNT Air Conditioners 2000-9000 BTU/HR.586-2637 WATTS
McLEAN MIDWEST CLOSED-LOOP COOLING
Within the air conditioner, the recirculated clean enclosure air is kept separate
from the ambient airflow system. This protects the electronic controls and
prevents shutdowns caused by heat, humidity, dust and other contaminants.
HB16HB30
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz
AIR
CO
ND
ITIO
NE
RS
HB
11,
HB
16,
HB
30
GENESIS™ HB11 Series2000-4000 BTU/Hr. (586-1172 Watts) H x W x D: 10.25" (260) x 17" (432) x 21.08" (535)
Full BTU/Hr @ Max Shipping
Load Max Amb Amb Temp Weight
Model Voltage Hz Amps Phase Temp °F/°C Lbs/Kgs
MHB11-0216-G306 STOCK 115 50/60 9.7/9.0 1 2200/2200 125/52 90/41
MHB11-0216-G3XX 115 50/60 9.7/9.0 1 2200/2200 125/52 90/41
MHB11-0226-G306 STOCK 230 50/60 5.5/4.6 1 2200/2200 125/52 90/41
MHB11-0226-G3XX 230 50/60 5.5/4.6 1 2200/2200 125/52 90/41
MHB11-0416-G307 STOCK 110/115 50/60 14.7/13.6 1 3300/4000 125/52 108/49
MHB11-0416-G3XX 110/115 50/60 14.7/13.6 1 3300/4000 125/52 108/49
MHB11-0426-G306 STOCK 220/230 50/60 8.0/7.5 1 3300/4000 125/52 108/49
MHB11-0426-G3XX 220/230 50/60 8.0/7.5 1 3300/4000 125/52 108/49
-XX will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers.An “M” in the model number identifies the new Genesis™ Series of air conditioners.
HB16 Series6000-9000 BTU/Hr. (1758-2637 Watts) H x W x D: 15.72" (399) x 19" (483) x 25.19" (640)
Full BTU/Hr @ Max Shipping
Load Max Amb Amb Temp Weight
Model Voltage Hz Amps Phase Temp °F/°C Lbs/Kgs
HB16-0615-0XX 115 50/60 13.0 1 5000/6000 125/52 145/66
HB16-0616-0XX 115 60 13.0 1 6000 125/52 140/64
HB16-0625-0XX 230 50 6.5 1 6000 125/52 140/64
HB16-0626-0XX 230 60 6.5 1 6000 125/52 140/64
HB16-0825-0XX 230 50 8.0 1 8000 125/52 145/66
HB16-0915-0XX 115 50/60 17.0 1 8500/9000 125/52 150/68
HB16-0916-0XX 115 60 19.0 1 9000 125/52 145/66
HB16-0926-0XX 230 60 9.5 1 9000 125/52 145/66
-XX will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers.Most models available with Hz selector, if desired. Contact factory.The 50/60 Hz units, because of the addition of an autotransformer, cost more than straight 60 Hz models. Units wired for 50 Hz operation when shipped. Asingle internal wiring change is required for 60 Hz operation.
HB30 Series6000 BTU/Hr. (1758 Watts) H x W x D: 14.13" (359) x 31.38" (797) x 15" (381)
Full BTU/Hr @ Max Shipping
Load Max Amb Amb Temp Weight
Model Voltage Hz Amps Phase Temp °F/°C Lbs/Kgs
HB30-0615-1XX 115 50/60 14.0 1 5000/6000 125/52 136/62
HB30-0616-1XX 115 60 14.0 1 6000 125/52 131/59
HB30-0625-1XX 230 50 7.0 1 6000 125/52 131/59
HB30-0626-1XX 230 60 7.0 1 6000 125/52 131/59
-XX will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers.Most models available with Hz selector, if desired. Contact factory.The 50/60 Hz units, because of the addition of an autotransformer, cost more than straight 60 Hz models. Units wired for 50 Hz operation when shipped. Asingle internal wiring change is required for 60 Hz operation.
TO
P-M
OU
NT
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz
CUT-OUT NOTES
1. Dash lines represent
air conditioner.
2. Cut-out dimensions
for standard product
only.
3. Full-size mounting
template provided.
GE
NE
SIS
™H
B11 S
ER
IES
HB
16 S
ER
IES
HB
30 S
ER
IES
CUT-OUT NOTES
1. Dash lines represent
air conditioner.
2. Entire weight of air
conditioner is not
intended to be
supported by the
mounting flanges. Slide
rails should be installed.
▲3. Cut-out and duct
or gasket required on
enclosure for condenser
air discharge.
4. Cut-out dimensions
for standard product
only.
CUT-OUT NOTES
1. Dash lines represent
air conditioner.
2. Cut-out dimensions
for standard product
only.
TOP SURFACE MOUNT TO
ENCLOSURE
For NEMA type 12 enclosure, interfacing air-out and
air-in openings are required in the enclosure top.
INTERNAL MOUNT
TO ENCLOSURE
For internal top mounting to NEMA
type 12 enclosures, slide rails should
be used. Cool air blows down.
TOP SURFACE
MOUNT TO
ENCLOSURE
For top mounting of air
conditioner, interfacing
air-out and air-in openings
are required in the top of
the enclosure. Special filter
frame required, consult
factory about model
specifications.
TOP SURFACE MOUNT
TO ENCLOSURE
For top mounting of air conditioner,
interfacing air-out and air-in openings are
required in the enclosure top surface.
TOP RECESSED
MOUNT TO
ENCLOSURE
Cool air blows down.
Consult factory when
ordering Series 30
RM. Air conditioner is
8.5" standard onto
the enclosure.
INTERNAL MOUNT
TOP SURFACE MOUNT
TOP RECESSED MOUNT
TOP SURFACE MOUNT
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz
DESIGN NOTES
1. Gasket kit for
mounting to enclosure
included.
▲2. Service cord.
3. Condensate from
enclosure drains to
bottom pan of unit
where it is evaporated
by condenser heat.
4. Condensate
overflow drain hose
included.
DESIGN NOTES
1. Gasket kit for
mounting to enclosure
included.
2. Service cord
terminated with
appropriate plug cap.
3. Condensate drain
hose with a “P” trap
included.
DESIGN NOTES
1. Gasket kit for
mounting to enclosure
included.
2. Service cord
terminated with
appropriate plug cap.
3. Condensate drain
hose included.
4. Unit is available
surface mounted as
shown or in partially
recessed mount
configuration.
AIR
CO
ND
ITIO
NE
RS
HB
11,
HB
16,
HB
30
TO
P-M
OU
NT
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz
AIR
CO
ND
ITIO
NE
RS
RC
R11,
LB
14,
LB
16
RCR11 LB14 LB16
RCR11 Series2000-4000 BTU/Hr. (586-1172 Watts) H x W x D: 10.47" (266) x 19" (483) x 21.47" (545)
Max Shipping
BTU/Hr @ Amps @ BTU/Hr @ Amps @ Amb Temp Weight
Model Voltage Hz Phase 131°F/131°F* 131°F/131°F 95°F/95°F* 95°F/95°F °F/°C Lbs/Kgs
RCR11-0216-G002 STOCK 115 50/60 1 1800/2000 9.0/9.0 1800/2000 8.0/7.4 131/55 95/43
RCR11-0216-G0XX 115 50/60 1 1800/2000 9.0/9.0 1800/2000 8.0/7.4 131/55 95/43
RCR11-0226-G0XX 230 50/60 1 1800/2000 5.1/4.7 1800/2000 4.7/3.9 131/55 95/43
RCR11-0416-G002 STOCK 115 50/60 1 3800/4000 12.9/12.9 3500/3500 11.1/9.9 131/55 107/49
RCR11-0416-G0XX 115 50/60 1 3800/4000 12.9/12.9 3500/3500 11.1/9.9 131/55 105/48
RCR11-0426-G0XX 230 50/60 1 3800/4000 7.1/7.1 3500/3500 5.6/5.0 131/55 105/48
-XX will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers.*Because air conditioners provide less cooling at lower operating temperatures, two cooling capacity ratings are listed for each ProAir™ air conditioner toassist you in your selection.
LB14 Series7000 BTU/Hr. (2051 Watts) H x W x D: 14.75" (375) x 19" (483) x 23.63" (600)
Full BTU/Hr @ Max Shipping
Load Max Amb Amb Temp Weight
Model Voltage Hz Amps Phase Temp °F/°C Lbs/Kgs
LB14-0715-0XX 115 50/60 15.0 1 5800/7000 125/52 140/64
LB14-0716-0XX 115 60 15.0 1 7000 125/52 135/61
LB14-0725-0XX 230 50 8.0 1 7000 125/52 135/61
LB14-0726-0XX 230 60 7.5 1 7000 125/52 135/61
-XX will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers.Most models available with Hz selector, if desired. Contact factory.The 50/60 Hz units, because of the addition of an autotransformer, cost more than straight 60 Hz models. Units wired for 50 Hz operation when shipped. Asingle internal wiring change is required for 60 Hz operation.
LB16 Series10000 BTU/Hr. (2930 Watts) H x W x D: 15.72" (399) x 19" (483) x 25.19" (640)
Full BTU/Hr @ Max Shipping
Load Max Amb Amb Temp Weight
Model Voltage Hz Amps Phase Temp °F/°C Lbs/Kgs
LB16-1016-0XX 115 60 20.0 1 10000 125/52 140/64
LB16-1025-0XX 230 50 10.0 1 10000 125/52 140/64
LB16-1026-0XX 230 60 10.0 1 10000 125/52 140/64
-XX will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers.Most models available with Hz selector, if desired. Contact factory.The 50/60 Hz units, because of the addition of an autotransformer, cost more than straight 60 Hz models. Units wired for 50 Hz operation when shipped. Asingle internal wiring change is required for 60 Hz operation.
RA
CK
-MO
UN
T
TM
❑ Ambient air flow❑ Clean air flow
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz
CUT-OUT NOTES
1. An envelope of
clean, cool air can
circulate around the
enclosed electronics
without the need for
additional baffling,
ducting or special
arrangement of enclosed
components.
RC
R11 S
ER
IES
LB
14 S
ER
IES
LB
16 S
ER
IES
CUT-OUT NOTES
1. Dash lines represent
air conditioner.
2. Entire weight of air
conditioner is not
intended to be
supported by the
mounting flanges. Slide
rails should be installed.
3. Cut-out dimensions
for standard product
only.
CUT-OUT NOTES
1. Dash lines
represent air
conditioner.
2. Entire weight of air
conditioner is not
intended to be
supported by the
mounting flanges. Slide
rails should be installed.
▲3. Cut-out and duct
or gasket required on
enclosure for condenser
air discharge.
4. Cut-out dimensions
for standard product
only.
RACK MOUNT TO ENCLOSURE
Patented airflow system will direct cool air
throughout enclosure allowing unit to be rack-
mounted at any location in enclosure.
RACK MOUNT TO ENCLOSURE
For mounting air conditioner to NEMA type 12
enclosure, slide rails should be installed. Cool air
blows up.
RACK MOUNT TO ENCLOSURE
For mounting air conditioner to NEMA type 12
enclosure, slide rails should be installed. Cool air
blows up.
TMOrder from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz
DESIGN NOTES
1. Gasket kit for
mounting to enclosure
included.
2. Service cord
terminated with
appropriate plug cap.
3. Required opening in
enclosure: 13.75" x
17.38"; minimum
enclosure depth: 25".
DESIGN NOTES
1. Gasket kit for
mounting to enclosure
included.
2. Service cord
terminated with
appropriate plug cap.
AIR
CO
ND
ITIO
NE
RS
RC
R11,
LB
14,
LB
16
RA
CK
-MO
UN
T
DESIGN NOTES
1. Gasket kit for
mounting to enclosure
included.
2. Service cord
terminated with
appropriate plug cap.
3. Condensate from
enclosure drains to
bottom pan of unit where
it is evaporated into
condenser air discharge.
4. Evaporator side
discharge chutes hinge
outward and are
reversible to allow
direction of air up or
down. Units are shipped
with chutes pointed up.
To direct air downward,
remove mounting screw
and exchange left and
right chutes. Reinstall
mounting screw in upper
hole.
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: [email protected] web: http://www.cuny.biz