optimal temperature control of rooms siri hofstad trapnes superviors: sigurd skogestad and chriss...
TRANSCRIPT
![Page 1: Optimal temperature control of rooms Siri Hofstad Trapnes Superviors: Sigurd Skogestad and Chriss Grimholt](https://reader036.vdocuments.us/reader036/viewer/2022082407/56649dc65503460f94aba4fc/html5/thumbnails/1.jpg)
Optimal temperature control of rooms
Siri Hofstad Trapnes
Superviors: Sigurd Skogestad and Chriss Grimholt
![Page 2: Optimal temperature control of rooms Siri Hofstad Trapnes Superviors: Sigurd Skogestad and Chriss Grimholt](https://reader036.vdocuments.us/reader036/viewer/2022082407/56649dc65503460f94aba4fc/html5/thumbnails/2.jpg)
The model
• Direct heating in floor and room
• Keep the temperature in the room within optimal bounds in order to save energy costs
![Page 3: Optimal temperature control of rooms Siri Hofstad Trapnes Superviors: Sigurd Skogestad and Chriss Grimholt](https://reader036.vdocuments.us/reader036/viewer/2022082407/56649dc65503460f94aba4fc/html5/thumbnails/3.jpg)
• Steps
1) Creating the model
- Matlab, Simulink
2) Implementation of the control structure
- PI control- SIMC
![Page 4: Optimal temperature control of rooms Siri Hofstad Trapnes Superviors: Sigurd Skogestad and Chriss Grimholt](https://reader036.vdocuments.us/reader036/viewer/2022082407/56649dc65503460f94aba4fc/html5/thumbnails/4.jpg)
• No heating in the floor• Constraints on the room
temperature– Intervals with
temperature equal to 10°C and 20°C
• Constant energy price– Minimum energy
consumption
![Page 5: Optimal temperature control of rooms Siri Hofstad Trapnes Superviors: Sigurd Skogestad and Chriss Grimholt](https://reader036.vdocuments.us/reader036/viewer/2022082407/56649dc65503460f94aba4fc/html5/thumbnails/5.jpg)
3) Finding the optimal temperature
- Quadratic programming
![Page 6: Optimal temperature control of rooms Siri Hofstad Trapnes Superviors: Sigurd Skogestad and Chriss Grimholt](https://reader036.vdocuments.us/reader036/viewer/2022082407/56649dc65503460f94aba4fc/html5/thumbnails/6.jpg)
4) Introducing disturbances5) The null space method- Even if time of switch changes with
disturbances the controlled variable should be constant
![Page 7: Optimal temperature control of rooms Siri Hofstad Trapnes Superviors: Sigurd Skogestad and Chriss Grimholt](https://reader036.vdocuments.us/reader036/viewer/2022082407/56649dc65503460f94aba4fc/html5/thumbnails/7.jpg)
- The null space method did not give acceptable results
• To• t switch• ∆T = Tr-To• Distance• Qh/r
• To• UAr/o
• Measurements: • Disturbances:
![Page 8: Optimal temperature control of rooms Siri Hofstad Trapnes Superviors: Sigurd Skogestad and Chriss Grimholt](https://reader036.vdocuments.us/reader036/viewer/2022082407/56649dc65503460f94aba4fc/html5/thumbnails/8.jpg)
Results from different combinations of measurements
To minus 10°C To plus 10°C
![Page 9: Optimal temperature control of rooms Siri Hofstad Trapnes Superviors: Sigurd Skogestad and Chriss Grimholt](https://reader036.vdocuments.us/reader036/viewer/2022082407/56649dc65503460f94aba4fc/html5/thumbnails/9.jpg)
The best combination of measurements and disturbances
To minus 5°C To plus 5°C
![Page 10: Optimal temperature control of rooms Siri Hofstad Trapnes Superviors: Sigurd Skogestad and Chriss Grimholt](https://reader036.vdocuments.us/reader036/viewer/2022082407/56649dc65503460f94aba4fc/html5/thumbnails/10.jpg)
Summary of obtained results
• Works fine around the nominal value (0°C)• The further away from the nominal value the
worse results• If good results above the nominal value then
not below 0°C
![Page 11: Optimal temperature control of rooms Siri Hofstad Trapnes Superviors: Sigurd Skogestad and Chriss Grimholt](https://reader036.vdocuments.us/reader036/viewer/2022082407/56649dc65503460f94aba4fc/html5/thumbnails/11.jpg)
• Improvements– Find controlled variable for all the switching times– Adjustments to the null space method