operator’s manual - kärcher international · amc / tds operator’s manual 3 s2%6 introduction...

38
OPERATOR’S MANUAL AMC/TDS AMC-1000 AMC-2000 AMC-3000 TDS-1000 For technical assistance or the Water Maze Dealer nearest you consult our web page at www.wmaze.com #8.913-965.0

Upload: phungnhan

Post on 04-Jan-2019

233 views

Category:

Documents


1 download

TRANSCRIPT

OPERATOR’S MANUAL

AMC/TDS

■ AMC-1000 ■ AMC-2000 ■ AMC-3000 ■ TDS-1000

For technical assistance or the Water Maze Dealer nearest youconsult our web page at www.wmaze.com

#8.913-965.0

CONTENTS

2

Form #8.913-965.0 • Revised 4/13

Model Number

Serial Number

Date of Purchase

The model and serial numbers will be found on a decal attached to the AMC/TDS-1000. You should record both serial number and date of purchase and keep in a safe place for future reference.

Introduction .................................................................................................................................... 3

Unpacking ...................................................................................................................................... 3

Specifications ................................................................................................................................. 3

Important Safety Information ......................................................................................................3-4

Operation AMC-2000 and AMC-3000 ............................................................................................ 4

Setting and Editing Current Time and Day ................................................................................ 4, 7

Component Identification AMC-1000/AMC-3000 ........................................................................... 5

Component Identification, AMC-2000 ............................................................................................ 6

Running Programs ......................................................................................................................7-8

Operation AMC-1000 ..................................................................................................................... 8

Operation TDS-1000 ...................................................................................................................... 8

Installation Instructions AMC-2000 ...........................................................................................8-17

Installation AMC-3000 ............................................................................................................18-27

Dump Valve Installation Instructions AMC-1000/AMC-3000 ........................................................ 28

TDS-1000 Installation Instructions ............................................................................................... 29

Control Panel Exploded View, AMC-2000/AMC-3000 ................................................................. 30

Control Panel Exploded View Parts List, AMC-2000/AMC-3000 ................................................. 31

Control Panel, Exploded View, AMC-1000/TDS-1000 ................................................................. 32

Control Panel, Exploded View Parts List, AMC-1000/TDS-1000 ................................................. 33

Exploded View, AMC-2000/AMC-3000 ........................................................................................ 34

Exploded View Parts List, AMC-2000/AMC-3000 ........................................................................ 35

Warranty ...................................................................................................................................... 37

AMC / TDS OPERATOR’S MANUAL 3

#8.913-965.0 • REV. 4/13

INTRODUCTIONYour owner’s manual has been prepared to provide you with a simple and understandable guide for equipment operation and maintenance, based on the latest product information available at the time of printing. To keep your machine in top running condition, follow the specific maintenance and troubleshooting procedures given in this manual.

NOTE: WATER MAZE reserves the right to make chang-es at anytime without incurring any obligations.

Owner/User Responsibility:The owner and/or user must have an understanding of the manufacturer’s operating instructions and warnings before using this WATER MAZE machine. Warning information should be emphasized and understood. If the operator is not fluent in English, the manufacturer’s instructions and warnings shall be read to and discussed with the operator in the operator’s native language by the purchaser/owner, making sure that the operator comprehends its contents.

SAVE THESE INSTRUCTIONS

The owner and/or user must study and maintain the manufacturers’ instructions for future reference.

This manual should be considered a permanent part of the machine and should remain with the machine if resold.

UNPACKING: AMC-2000/3000 1. AMC Bracket Assembly 2. Manifold 3. Accessory Box

4. Operator’s Manual

Note any damage to machine or components for claims against the freight lines.

UNPACKING: AMC-1000/TDS-1000 1. AMC-1000/TDS-1000 Control Box2. Operator's Manual

Note any damage to machine or components for claims against the freight lines.

SPECIFICATIONSAir Requirements: 3 CFM, 60-100 PSI (AMC Units Only)

Voltage: Supply Voltage from Base Machine

Dimensions: AMC-2000/3000, Length 55" Width 19" Height 31"

Dimensions: AMC-1000/TDS-1000, Length 15.5" Width 8" Height 16"

Weight: AMC-2000/3000, 150 Lbs

Weight: AMC-1000/TDS-1000, 15 Lbs

IMPORTANT SAFETY INFORMATION

CAUTION: To reduce the risk of in-jury, read operating instructions carefully before using.

1. Read the owner’s manual thoroughly. Failure to follow the instructions will cause a malfunction of the machine and result in death, serious injury and/or property damage.

WARNING: Ground system before connecting to the power supply.

WARNING: Wire the system for correct voltage. See Electrical section (Page 9) of this manual and motor nameplate.

WARNING: Meet the National Electrical Code and local codes for all wiring.

WARNING: Follow the wiring instructions in this manual when connecting the system to the power lines.

WARNING: All wiring must be performed by a quali-fied electrician.

2. Know the system application, limitations, and poten-tial hazards.

3. WARNING: Risk of electric shock.

All wiring should be performed by a qualified electri-cian.

4. Never make adjustments on the machine while it is in operation, except for those prescribed in this manual.

5. The power must be brought from the base machine and wired into the electrical box on the AMC or TDS.

6. Before servicing the machine, refer to all the MSDS’s on the material identified in the waste stream. You must comply with all warnings and wear all protective clothing as stated on the MSDS’s.

7. Protect all electrical cords from sharp objects, hot surfaces, oil, sunlight, and chemicals. Avoid kinking the cords. Replace or repair damaged or worn cords immediately.

8. Inlet water temperature must not exceed 85°F.

9. Disconnect the power before servicing this machine. If the power disconnect is out of sight, lock it in the open position and tag it to prevent unexpected application of power.

10. The best insurance against an accident is precaution and knowledge of the equipment.

WARNING

KEEP WATER SPRAY AWAY FROM

ELECTRICAL WIRING.

WARNING

READ OPERATOR’S MANUAL

THOROUGHLY PRIOR TO USE.

CAUTION

4 AMC / TDS OPERATOR’S MANUAL

#8.913-965.0 • REV. 4/13

11. WATER MAZE is not liable for modifications or use of components not purchased from WATER MAZE.

12. Personal Safety:

a. Wear safety glasses and other applicable pro-tective clothing at all times when working on the AMC or TDS.

Refer to item #6 under Important Safety Information.

b. Keep your work area clean, uncluttered and properly lighted. Replace all unused tools and equipment.

c. Keep visitors at a safe distance from the work area.

d. Make the workshop safe with padlocks and master switches.

13. Release all pressure within the system before servic-ing any component.

14. Drain all liquids from the component before servicing.

15. Check hoses for weak or worn condition before each use, making certain that all connections are secure.

16. Periodically inspect system components. Perform routine maintenance as required.

17. Do not stand on the bracket or electrical box.

18. Keep from freezing.

19. Do not spray water directly at machine.

OPERATION: AMC-2000 & AMC-3000Automatic Backwash ModeBackwashing the multi-media and carbon filters is required to rejuvenate the filter media. Backwashing removes collected materials and disperses the media to eliminate any channeling. The AMC-2000 & 3000 automatically backwash these filters every day based on input from the AMC controller. When you program the AMC controller, per the instructions on pages 7 and 8, the multi-media will start backwashing at midnight for 30 minutes. The unit will recover the water level in Tank #1 and then backwash the carbon filter. The operator cannot use the pressure washer at that time, so it is important that the program imitates your schedule. If it doesn’t, call the factory for assistance in reprogramming your controller.

To backwash the multi-media filter, the AMC controller energizes the air actuated three way valves (ASV1, ASV2). A slip stream solenoid (WSV1) is activated and water flow to the multi-media filter should be adjusted to 30 GPM using WSV1 flow control valve. Water is pumped from Tank #1 through the filter by the filter

pump. This process continues for 30 minutes and the resulting backwash outflow is returned to the wash pad catch basin. The AMC controller will then wait 15 min-utes to allow Tank #1 to refill. To backwash the carbon, the AMC controller energizes the air actuated three way valves (ASV1, ASV3, ASV4). The flow through the carbon filter should be set to 15-20 GPM using carbon valve BV2. This process continues for 30 minutes and the resulting backwash outflow is returned to the wash pad catch basin.

Automatic Sludge Dump (AMC-3000 Only)During normal operation, the settling properties of the solids will result in sludge build-up inside the cone bottom clarifier tank. This sludge must be periodically removed. This is accomplished once each day by an automated sludge dump system.

To dump sludge, the AMC controller energizes an air activated dump valve (ASV5) while simultaneously en-ergizing a water solenoid (WSV2). The water solenoid will stir-up any impacted material in the bottom of the cone bottom tank and allow sludge to flow to the sludge collection bag. To reduce excess water in the sludge bag, the water solenoid is only activated for a few seconds. Once the dump valve closes, the sludge bag is allowed to de-water and excess water is returned, via gravity feed, to the wash pad catch basin.

PROGRAMMING THE AMC (AUTOMATIC MAINTENANCE CONTROLLER)The AMC Controller needs to be programmed on site. The reason for this is when power is cut to the unit the program is lost. There is a 9V battery inside the AMC Controller (pull down on bottom cover of the AMC) that will power the controller and hold the program for ap-proximately 72 hours. The 9V battery will take care of intermittent power loss but will not hold program from factory to site during shipping. Before programming, con-nect battery inside AMC. Replace battery yearly.

SETTING/EDITING CURRENT TIME AND DAY 1. Turn control dial to SET TIME & DAY position.

2. To set current hour, press +/ON or -/OFF button.

3. Press the NEXT button.

4. To set current minute, press +/ON or -/OFF button.

5. Press the NEXT button.

6. To set current day, press +/ON or -/OFF button until current day is flashing.

7. Return dial to the AUTO/ON position.

AMC / TDS OPERATOR’S MANUAL 5

#8.913-965.0 • REV. 4/13

COMPONENT IDENTIFICATIONAMC-1000/3000

Air Regulator

WSV2

AMC-1000 or TDS-1000

WSV1ASV1

BV2

ASV4

Control Box

AMC-2000 or AMC-3000

ASV2

ASV5

ASV3BV1

CLP-5023,7023,7033

6 AMC / TDS OPERATOR’S MANUAL

#8.913-965.0 • REV. 4/13

COMPONENT IDENTIFICATIONAMC-2000

ASV1

AMC-2000

TDS-1000

Control Box

BV2

ASV4

ASV3

WSV1

BV1

Delta 1500, 3000

ASV2

AMC / TDS OPERATOR’S MANUAL 7

#8.913-965.0 • REV. 4/13

PROGRAMMING BACKWASH & DUMP MODESThe backwash program requires (3) basic instructions to operate automatically:

A. Operation Days (Usually 7 days a week).

B. Start Time (Usually at night when washing is not being performed).

C. Mode Run Times (length of backwash and recircula-tion times)

A. Setting/Editing Program Operation Days 1. Turn control dial to SET PROGRAM OPERATION

DAYS.

2. Set program switch to program A, B, or C. (See Pro-gram Schedule Sheet for program descriptions).

3. Press +/ON or -/OFF button until CAL (calendar) is flashing.

4. Press the NEXT button to see program operation days. SU (Sunday) will begin flashing.

5. To select the day (flashing), press the +/ON button. To remove a day, press the -/OFF button.

6. Repeat step 5 until all operation days are selected.

7. Repeat steps 1-6 for Programs A, B, or C.

8. Return dial to the AUTO/ON position.

B. Setting/Editing Program Start Time 1. Turn control dial to SET PROGRAM START TIME.

2. Set program switch to program A, B, or C. (See Pro-gram Schedule Sheet for program descriptions).

3. Press +/ON or -/OFF button until program start time number 1 is flashing (upper left corner of display).

4. Press the NEXT button.

5. To set the hour, press +/ON or -/OFF button.

6. Press the NEXT button.

7. To set the minute, press +/ON or -/OFF button.

NOTE: Programs 2, 3, 4 should read OFF.

8. Return dial to the AUTO/ON position.

C. Setting/Editing Mode Run Times 1. Turn control dial to SET MODE RUN TIMES.

2. Set program switch to program A, B, or C (see Pro-gram Schedule Sheet for program descriptions).

3. Mode number 1 will begin flashing (lower left corner of display).

4. Press the NEXT button. Mode number will stop flash-ing and timer display or “OFF” will begin flashing.

5. To set run time, press +/ON or -/OFF button.

NOTE: To remove (skip) a mode, press the +/ON and -/OFF buttons at the same time. OFF should be displayed. (Refer to Program schedule sheet below, e.g. Program A, Mode 1 is 30 minutes).

6. Press the NEXT button. The next mode number will begin flashing.

7. Repeat steps 4-6 until all run times have been set for modes 1-6.

8. Repeat steps 1-7 for Programs A, B, and C.

9. Return dial to the AUTO/ON position.

PROGRAM SCHEDULE SHEETThe Program Schedule Sheet shows descriptions of Modes, Programs and Recommended Settings:

PROGRAM AAuto Backwash

7 days/week

PROGRAM BManual Backwash

PROGRAM CTest Mode

MODE DESCRIPTION MODE RUN TIME MODE RUN TIME MODE RUN TIME

1 Media Backwash 30 minutes 30 minutes 5 minutes

2 Tank 1 Recovery 15 minutes 15 minutes 5 minutes

3 Carbon Backwash 30 minutes 30 minutes 5 minutes

4 Auto Purge (AMC-3000) 15 minutes OFF 5 minutes

ProgramStart Times

1 12:00 AM OFF OFF

2 OFF OFF OFF

3 OFF OFF OFF

4 OFF OFF OFF

8 AMC / TDS OPERATOR’S MANUAL

#8.913-965.0 • REV. 4/13

RUNNING PROGRAMSAuto Backwash (Program A) - Used for Daily Operations 1. Set program switch to Program A.

2. Turn control dial to AUTO/ON position. Program will cycle through modes 1-4 when start time is reached. Mode number and program letter will flash to indi-cate status. Display will show time remaining in that mode.

3. AMC-2000/3000 will return to filter mode when mode 4 is complete.

Manual Backwash (Program B) 1. Set program switch to Program B.

2. Turn control dial to AUTO/ON position.

3. Press the MANUAL START button twice. CLP will cycle through the following modes:

• Media Backwash

• Tank 1 Recovery

• Carbon Backwash

4. To skip a mode, press the NEXT button.

5. To pause a mode, press +/ON and -/OFF buttons at the same time. To resume, press the NEXT button.

6. To cancel program press +/ON and -/OFF buttons at the same time, twice.

7. Set program switch back to Program A to resume Auto Backwash program.

Test Program (Program C) 1. Set program switch to Program C.

2. Turn control dial to AUTO/ON position.

3. Press the MANUAL START button.

4. See Running Manual Backwash instructions above to pause, skip and cancel programs.

5. Set program switch back to Program A to resume.

OPERATION: AMC-1000During normal operation, the settling properties of solids will result in sludge build-up inside the cone bottom of the clarifier tank. This sludge must be periodically removed. The AMC-1000 automated sludge dump system is de-signed to remove solids each day.

To dump sludge from the cone bottom tank, a 24-hour timer in the AMC-1000 control box energizes an air activated dump valve (ASV5). The duration of the dump mode can be adjusted by a second timer (measured in seconds). Once the dump valve closes, the sludge bag is allowed to de-water and excess water is returned, via gravity feed, to the wash pad catch basin.

OPERATION: TDS-1000The TDS-1000 dramatically reduces the Total Dissolved Solids (TDS), Total Suspended Solids (TSS) and even detergents that can accumulate in a recycle system. The TDS-1000 is designed to remove a specified volume of water from the system each day. The freshwater make-up system on the CLP or Delta will then add fresh water to the system.

To purge water from the CLP or Delta system, a 24-hour timer in the TDS-1000 control box energizes the rain water solenoid found on the water connection panel. The transfer pump will turn on and discharge water from tank #2 to a holding tank or to sewer (if permitted). The duration of the dump mode and therefore the amount of water purged can be adjusted by a second timer. The freshwater solenoid on the water connection panel is disabled while the system purges. A N/C float is supplied with the TDS-1000 to prevent overflowing the water in the holding tank.

INSTALLATION INSTRUCTIONS: AMC-2000NOTE: Different models and years of manufactur-ing may have been built slightly different from the instructions below. It is recommended you have a va-riety of fittings available for those slight differences.

Tools & Supplies • 1" Hole Saw

• Large Channel Locks

• Medium Straight Screw Driver

• Small Straight Thin Screw Driver

• Hack Saw - Don't Use Pipe Cutter

• Tape Measure

• Drill

• Teflon Tape

• Purple Primer

• Heavy Duty Gray PVC Cement

• Rags

Wire/Conduit — depends upon amp draw of machine and filter pump. Follow local codes.

Electrical fittings (Spader, butt connector, etc.)

Wire Strippers

Wire Cutters

AMC / TDS OPERATOR’S MANUAL 9

#8.913-965.0 • REV. 4/13

ElectricalRefer to Wiring Diagram

1. Run power for the AMC-2000 from the power inlet terminal block of the Delta. (Wire not supplied.)

2. Run filter pump wires from AMC-2000 to the filter pump motor. Wire the same way it is wired from main control box. Install a tee at the motor to ac-cept the line from the AMC. On a three-phase unit, make sure filter pump is spinning in the correct rotation from both power sources. (Wire not sup-plied.)

3. Run the black N/O float from the AMC to the filter pump tank. Tie wrap N/O float to existing low water float in filter pump tank.

Air 1. Air is required to operate air valves. 3 CFM with 60-

100 psi will meet air requirements.

2. An air regulator valve is provided.

3. Connect air hose to auto dump valve.

10 AMC / TDS OPERATOR’S MANUAL

#8.913-965.0 • REV. 4/13

AMC-2000INSTALLATION INSTRUCTIONS

Step 1. Hang AMC-2000 bracket assembly on side rail of Delta skid.

Step 2. Attach manifold to AMC-2000. Line up half-unions on manifold with half-unions on AMC bracket assembly. Make sure o-rings are in place. Tighten unions.

AMC-2000 Bracket Assy

AMC-2000 Manifold Assy

AMC / TDS OPERATOR’S MANUAL 11

#8.913-965.0 • REV. 4/13

AMC-2000INSTALLATION INSTRUCTIONS (CONTINUED)

Step 6. Install 1-1/2" plug (item 1) into backwash port on valve head.

Step 7. Install pipe nipple (item 3) and union (item 2) into outlet port on valve head. (This will connect to the AMC-2000 at a later step.)

Step 8. Take half of new slip x slip 1-1/2" union (item 5) and couple to remaining half union on line to water storage tank. If existing union on water storage line is different from one supplied, cut old union off and install new union.

Backwash Port

Cartridge Filters

Carbon Filter

Carbon Filter

Diverter Valve

Outlet Port

Diverter Valve

Outlet Port

2

4

1

1

3

5

ITEM PART NO. DESCRIPTION 1 2-0100146 Plug, 1-1/2", PVC 80

2 2-01004301 Union, 1-1/2" Slip x Thread, PVC 80 Spears

3 2-01002 Nipple, 1.5" x Close, PVC 80

Step 3. Break pipe union coming off of carbon tank backwash port. Cut pipe to return line leav-ing enough stub for female adapter. Remove remaining fittings from diverter valve backwash port.

Step 4. Break pipe union on outlet of carbon filter. Remove remaining adapter from valve head.

Step 5. Glue slip x thread 1-1/2" adapter (item 4) to return line and install 1-1/2" plug (item 1) into adapter.

ITEM PART NO. DESCRIPTION 4 2-0100312 Adapter, 1.5" x 1.5", Ft x Slip, PVC 80

5 2-0100430 Union, 1-1/2" Slip x Slip, PVC 80 Spears

Backwash Port

44

3

3

87

5

6

12 AMC / TDS OPERATOR’S MANUAL

#8.913-965.0 • REV. 4/13

AMC-2000INSTALLATION INSTRUCTIONS (CONTINUED)

Step 9. Drain cartridge filters. Break union on inlet port of carbon filter. Remove pipe assembly as shown. Make sure to close cartridge filter drain valve when finished.

Step 10. Couple half of new slip x thread 1-1/2" union (item 1) and pipe nipple (item 2) to remaining half union on inlet port of carbon filter.

Inlet Port

Cartridge Filters

Carbon Filter

Diverter Valve

1

2

Carbon Filter

Inlet Port

ITEM PART NO. DESCRIPTION 1 2-01004301 Union, 1-1/2" Slip x Thread, PVC 80 Spears

2 2-01002 Nipple, 1.5" x Close, PVC 80

9

9

9

10

AMC / TDS OPERATOR’S MANUAL 13

#8.913-965.0 • REV. 4/13

AMC-2000INSTALLATION INSTRUCTIONS (CONTINUED)

Step 11. Break union on outlet port of multi-media filter. Remove pipe assembly as shown.

Cartridge Filters

1/2" Slip x Thread Union

Multi-Media Filter

Multi-Media Filter Diverter

Valve

OutletPort

Multi-Media Filter Diverter

Valve Outlet Port

2

1

ITEM PART NO. DESCRIPTION 1 2-01004301 Union, 1-1/2" Slip x Thread, PVC 80 Spears

2 2-01002 Nipple, 1.5" x Close, PVC 80

Step 12. Couple slip half of new slip x thread 1-1/2" union (item 1) to remaining half union on outlet port of multi-media filter diverter valve. If different style of union, remove old union and install nipple (item 2) and new union (item 1).

11

11

12

11

11

14 AMC / TDS OPERATOR’S MANUAL

#8.913-965.0 • REV. 4/13

AMC-2000INSTALLATION INSTRUCTIONS (CONTINUED)

ITEM PART NO. DESCRIPTION 1 2-0100146 Plug, 1-1/2", PVC 80

2 2-01004301 Union, 1-1/2" Slip x Thread, PVC 80 Spears

ITEM PART NO. DESCRIPTION 3 2-01002 Nipple, 1.5" x Close, PVC 80

4 2-0100430 Union, 1-1/2" Slip x Slip, PVC 80 Spears

Step 13. Break union on inlet port of multi-media filter and remove fittings as shown.

Step 14. Break union on backwash port of multi-media filter and remove fittings as shown.

Step 15. Install 1-1/2" plug (item 1) into back wash port on valve head.

Multi-Media Filter

CarbonFilter

Step 16. Take half of new slip x thread 1-1/2" union (item 2) and couple to remaining half union on inlet port of multi-media filter or install new union.

Step 17. Take half of new slip x slip 1-1/2" union (item 4) and couple to remaining half union on inlet line (to filter pump).

Multi-Media Filter

Multi-Media Filter

1

3

2

4

Backwash PortInlet

Port

Inlet Port

Backwash Port

Inlet Port

Multi-Media Filter Diverter Valve 14

13

15 17

16

AMC / TDS OPERATOR’S MANUAL 15

#8.913-965.0 • REV. 4/13

AMC-2000INSTALLATION INSTRUCTIONS (CONTINUED)

Step 18. Measure, cut and glue 1-1/2" gray hose (item 1) from inlet port on carbon filter to inlet port on AMC-2000. Prepare hose ends with purple primer and glue using heavy duty gray pvc ce-ment. Repeat for outlet port of carbon filter.

Step 19. Measure, cut and glue 1-1/2" gray hose from inlet port of multi-media filter to inlet port of AMC-2000. Repeat for outlet port of multi-me-dia filter.

Diverter Valve

1-1/2" Gray Hose

Inlet Port

Carbon Filter

Outlet Port

1-1/2" Gray Hose

1-1/2" Gray Hose

AMC-2000 Multi-Media

Inlet

AMC Bracket

Assembly

AMC-2000 Multi-Media

Outlet

Outlet Port

AMC-2000 Carbon Filter

Outlet

1/2" Slip Union

Inlet Port

Multi-Media Filter

1-1/2" Gray Hose

AMC Bracket

Assembly

Diverter Valve

AMC-2000 Carbon Filter

Inlet

1

1

1

1

ITEM PART NO. DESCRIPTION 1 4-02190003 Hose, 1-1/2", Gray Spiralite, 50 ft.

19

16 AMC / TDS OPERATOR’S MANUAL

#8.913-965.0 • REV. 4/13

AMC-2000INSTALLATION INSTRUCTIONS (CONTINUED)

Step 20. Measure, cut and glue 1-1/2" gray hose (item 1) from half of slip x slip 1-1/2" union (item 2) on backwash line to backwash port on AMC-2000 manifold.

Step 21. Measure, cut and glue 1-1/2" gray hose from 1-1/2" union on inlet line (from filter pump) to multi-media inlet union on AMC-2000 mani-fold.

Open original filter flow valve to full flow. BV1 is now the valve you adjust for your filter flow.

Step 22. Measure, cut and glue 1-1/2" gray hose from 1-1/2" union on clean water tank line (to alpha tank) to filtered water port on AMC-2000 mani-fold.

To Backwash Line

AMC-2000 Multi-Media Inlet Union

1-1/2" Gray Hose

To 1-1/2" Gray Hose

To Clean Water Tank1-1/2" Slip

Union

Flow Meter

To Backwash Port

AMC-2000 Manifold

Assembly Filtered Water Port

1-1/2" Gray Hose

To Filter Pump

1

1

2

1

ITEM PART NO. DESCRIPTION 1 4-02190003 Hose, 1-1/2", Gray Spiralite, 50 ft

2 2-0100430 Union, 1-1/2" Slip x Slip, PVC 80 Spears

Filter Pump Inlet

22

20

22

20

21

21

AMC / TDS OPERATOR’S MANUAL 17

#8.913-965.0 • REV. 4/13

AMC-2000INSTALLATION INSTRUCTIONS (CONTINUED)

Step 23. Wire filter pump to AMC-2000 control box as shown. (Wire not provided.) See wiring dia-gram.

Step 24. Run AMC-2000 float into filter pump tank. Tie wrap float to existing low level float.

Filter Pump

Tie Wrap

ITEM PART NO. DESCRIPTION 1 6-02177 Switch, Float, N/O, .20 MDWOP, 1003825, Black 2 2-0100200 Tee, 1/2" FT x FT x FT, PVC 80 3 2-0100399 Nipple, 1/2", PVC 80

1

Low Water Float From AMC-2000

2

323

24

18 AMC / TDS OPERATOR’S MANUAL

#8.913-965.0 • REV. 4/13

INSTALLATION INSTRUCTIONS: AMC-3000Note: Different models and years of manufactur-ing may have been built slightly different from the instructions below. It is recommended you have a variety of fittings available for those slight differ-ences.

Tools & Supplies • 1" Hole Saw

• Large Channel Locks

• Medium Straight Screwdriver

• Small Straight Thin Screwdriver

• Hack Saw - Don't Use Pipe Cutter

• Tape Measure

• Drill

• Teflon Tape

• Purple Primer

• Heavy Duty Gray PVC Cement

• Rags

Wire/Conduit — depends upon amp draw of machine and filter pump. Follow local codes.

Electrical fittings (Spader, butt connector, etc.)

Wire Strippers

Wire Cutters

ElectricalRefer to Wiring Diagram.

1. Run your power for the AMC-3000 from the power inlet terminal block of the CLP.

2. Run filter pump wires from AMC-3000 to the filter pump motor. Wire the same way it is wired from main control box. Install tee at motor to accept the line from the AMC. If a three-phase unit, make sure filter pump is spinning in the correct rotation from both power sources.

3. Run the black N/O float from the AMC to tank 1. Drain water from tank 1. Drill hole in tank and position float at the same height as FS4. Use bulkhead and water tight strain relief.

4. Connect solenoid coil wire from auto dump valve to AMC.

Air 1. Air is required to operate air valves. 3 CFM with 60-

100 psi will meet air requirements.

2. An air regulator valve is provided.

3. Connect air hose to auto dump valve (AMC-1000/AMC-3000).

AMC / TDS OPERATOR’S MANUAL 19

#8.913-965.0 • REV. 4/13

AMC-3000INSTALLATION INSTRUCTIONS

Step 1. Hang AMC-3000 bracket assembly on end rail of CLP.

AMC-3000 Manifold

Assembly

AMC-3000 Bracket

Assembly

Step 2. Attach manifold to AMC-3000. Line up half-unions on manifold with half-unions on AMC bracket assembly. Make sure o-rings are in place. Tighten unions.

20 AMC / TDS OPERATOR’S MANUAL

#8.913-965.0 • REV. 4/13

Step 3. Break pipe union coming off of multi-media tank diverter valve that goes to return line. Follow this line down to return line and break that union or unions. Remove pipe. (On some models you may also have to break unions on carbon filter to remove this pipe.

Step 4. Remove remaining elbow and adapter from multi-media valve head. Install 1-1/2" plug (item 1) into valve head port.

Step 5. Take threaded half of slip x thread 1-1/2" union (item 2) and couple to remaining half union coming off return line. If existing union on return line is different from one supplied, cut old union off and install new union. Thread in 1-1/2" pipe (item 1) plug into this union. (Depending on model and when it was built you may not need to do this. What you need is one line open going to the return line. Most CLP machines have two - so on those units you will need to plug one.)

Storage Tank #1

Multi-Media Tank Diverter Valve

Storage Tank #2

Multi-Media Filter

Return Line

1

Multi-Media Valve Head Port

Storage Tank #1

Storage Tank #2

Return Line

AMC-3000INSTALLATION INSTRUCTIONS (CONTINUED)

2

1

ITEM PART NO. DESCRIPTION 1 2-0100146 Plug, 1-1/2", PVC 80

2 2-01004301 Union, 1-1/2" Slip x Thread, PVC 80 Spears

3

3

4

4

5

5

AMC / TDS OPERATOR’S MANUAL 21

#8.913-965.0 • REV. 4/13

AMC-3000INSTALLATION INSTRUCTIONS (CONTINUED)

Storage Tank #1

Storage Tank #2

New Slip x Slip Half

Union

Low Level Float

Storage Tank #1

Clear Pipe

Flow Meter

Pressure Switch

1

4

2

3

ITEM PART NO. DESCRIPTION 1 2-01001391 Plug, 1/2" MIPT, PVC 80

2 2-010049 Bulkhead, 1/2" PVC

ITEM PART NO. DESCRIPTION 3 6-02177 Switch, Float, N/O, .20 MDWOP, 1003825, Black

4 2-0100430 Union, 1-1/2" Slip x Slip, PVC 80 Spears

Step 6. Remove pressure switch. Install plug (item 1). Run wires to pressure switch located on AMC-3000.

Step 7. Break union on clear pipe between filter flow meter and inlet of multi-media valve. Push clear pipe back a few inches. (Check that valve coming out of filter pump will allow this.) Open valve completely for full flow. BV1 is now the valve you adjust for your filter flow.

Step 8. Take half of new slip x slip 1-1/2" union (item 4) and couple to remaining half union coming off clear pipe. (If different union than one supplied, replace entire union.)

Step 9. Drill 1-1/8" hole inside of storage tank #1 as shown. Install new low-level float ( item 3) pro-vided.

Multi-media

Valve Inlet

Hole1-1/8"

Bulkhead Assy.

22 AMC / TDS OPERATOR’S MANUAL

#8.913-965.0 • REV. 4/13

Step 11. From the outlet of multi-media diverter valve install half of union to remaining half of union. Glue elbows (item 3) to union (item 1) on di-verter valve as shown. Measure, cut and glue 1-1/2" gray hose (item 2) to Multi-Media inlet port on AMC-3000.

AMC-3000INSTALLATION INSTRUCTIONS (CONTINUED)

ITEM PART NO. DESCRIPTION 1 2-01004301 Union, 1-1/2" Slip x Thread, PVC 80 Spears

2 4-02190003 Hose, 1-1/2", Gray Spiralite, 50 ft.

ITEM PART NO. DESCRIPTION 3 2-01001322 Elbow, 1-1/2" S x S, PVC 80, 90°

4 2-01002 Nipple, 1.5" x Close, PVC 80

5 2-010008 Pipe, 1.5", PVC 80, 3 ft.

Multi-Media Filter

AMC-3000 Multi-Media Inlet Union

Union On Clear Pipe

1-1/2" Gray Hose

1-1/2" Gray Hose

AMC-3000 Multi-Media Inlet

Diverter Valve Outlet

2

4

1

5

3

5

3

2

Step 10. Measure and cut 1-1/2" gray hose (item 2) to fit from union on clear pipe to multi-media inlet union on AMC-3000 manifold assembly. Using "purple primer" prime end of hose going into union on clear pipe. Using "heavy duty gray PVC cement," glue in hose. Slide opposite end of hose into AMC-3000 inlet union and repeat same procedure.

AMC / TDS OPERATOR’S MANUAL 23

#8.913-965.0 • REV. 4/13

Step 12. Drain cartridge filter. Disconnect plumbing from multi-media filter to cartridge filter. NOTE: Because you are removing the cartridge filter/filters you may want to replace your multi-media with garnet to provide finer filtering.

AMC-3000INSTALLATION INSTRUCTIONS (CONTINUED)

AMC-3000 Multi-Media

Outlet

Diverter Valve Outlet

Multi-Media Filter

1-1/2" Gray Hose

Cartridge Filter

Multi-Media Filter

To AMC-3000 Multi-Media

Outlet

4

3 1

5

3

5

2

ITEM PART NO. DESCRIPTION 1 2-01004301 Union, 1-1/2" Slip x Thread, PVC 80 Spears

2 4-02190003 Hose, 1-1/2", Gray Spiralite, 50 ft.

ITEM PART NO. DESCRIPTION 3 2-01001322 Elbow, 1-1/2" S x S, PVC 80, 90°

4 2-01002 Nipple, 1.5" x Close, PVC 80

5 2-010008 Pipe, 1.5", PVC 80, 3 ft.

Step 13. Attach half of union to remaining half union coming from outlet of multi-media diverter valve. Glue elbow (item 3) to union (item 1) on diverter valve as shown. Measure, cut and glue 1-1/2" gray hose (item 2) to Multi-Media port on AMC-3000 outlet.

24 AMC / TDS OPERATOR’S MANUAL

#8.913-965.0 • REV. 4/13

Storage Tank #2

1-1/2" Gray Hose

Carbon Filter

Storage Tank #2

AMC-3000 Carbon

Filter Outlet

Cartridge Filter

Carbon Filter

AMC-3000INSTALLATION INSTRUCTIONS (CONTINUED)

Step 14. Remove plumbing from cartridge filter to carbon filter.

Step 15. Attach half union to remaining union (item 1) on inlet to carbon filter. Glue elbow (item 3) to union on diverter valve as shown. Measure, cut, and glue 1-1/2" gray hose (item 2) to carbon inlet on AMC-3200.

3

2

4

51

Diverter Valve Inlet

ITEM PART NO. DESCRIPTION 1 2-01004301 Union, 1-1/2" Slip x Thread, PVC 80 Spears

2 4-02190003 Hose, 1-1/2", Gray Spiralite, 50 ft.

ITEM PART NO. DESCRIPTION 3 2-01001322 Elbow, 1-1/2" S x S, PVC 80, 90°

4 2-01002 Nipple, 1.5" x Close, PVC 80

5 2-010008 Pipe, 1.5", PVC 80, 3 ft.

AMC / TDS OPERATOR’S MANUAL 25

#8.913-965.0 • REV. 4/13

Step 16. Remove plumbing from return line off of the carbon filter diverter valve to return line. Plug both ends. Remove plumbing from carbon filter diverter valve going to storage tank #2.

Step 17. Attach half union to remaining union (item 2) on outlet from carbon filter. Glue elbow (item 4) to union diverter valve as shown. Measure, cut and glue 1-1/2" gray hose (item 3) to carbon outlet port on AMC-3000.

AMC-3000INSTALLATION INSTRUCTIONS (CONTINUED)

1-1/2" Gray Hose

Storage Tank #2

Return Line

Storage Tank #2

Carbon Filter Diverter Valve

Carbon Filter

AMC-3000 Carbon Filter Outlet

Carbon Filter

1

5

2

2

4

6

4

3

6

ITEM PART NO. DESCRIPTION 1 2-0100146 Plug, 1-1/2", PVC 80

2 2-01004301 Union, 1-1/2" Slip x Thread, PVC 80 Spears

3 4-02190003 Hose, 1-1/2", Gray Spiralite, 50 ft.

ITEM PART NO. DESCRIPTION 4 2-01001322 Elbow, 1-1/2" S x S, PVC 80, 90°

5 2-01002 Nipple, 1.5" x Close, PVC 80

6 2-010008 Pipe, 1.5", PVC 80, 3 ft.

1

26 AMC / TDS OPERATOR’S MANUAL

#8.913-965.0 • REV. 4/13

AMC-3000INSTALLATION INSTRUCTIONS (CONTINUED)

Step 18. Build plumbing coming out of storage tank #2 to AMC-3000 outlet elbow as shown.

Step 19. Connect plumbing coming out of AMC-3000 to union going to return line as shown

Return Line

Storage Tank #2

1-1/2" Gray Hose

AMC-3000 Outlet Elbow

1-1/2" Gray Hose

2

1

2

1

ITEM PART NO. DESCRIPTION QTY. 1 4-02190003 Hose, 1-1/2", Gray Spiralite, 50 ft.

2 2-0100430 Union, 1-1/2" Slip x Slip, PVC 80 Spears

AMC / TDS OPERATOR’S MANUAL 27

#8.913-965.0 • REV. 4/13

AMC-3000INSTALLATION INSTRUCTIONS (CONTINUED)

Step 20. Wire filter pump to AMC-3000 control box as shown.

Step 21. Wire low limit float (items 4 & 6) installed in storage tank #1 into AMC-3000 control box as shown.

Storage Tank #1

Main Tank Cone

Dump Valve

Assembly

1

ITEM PART NO. DESCRIPTION 1 4-02100000 Hose, 1/4", Push-On, Fuel Line, 15 ft

2 2-0100399 Nipple, 1/2", PVC 80 Close

3 2-0100200 Tee, 1/2" Ft x Ft x Ft, PVC 80

4 6-05153 Strain Relief, STRT, LQ Tite 3200

ITEM PART NO. DESCRIPTION 5 2-1089 Hose Barb, 1/4" Barb x 1/4" Pipe, 90°

6 6-02177 Switch, Float, N/O Black

7 6-140166 Solenoid, Water Maze, PVC, 24V

Step 22. Wire dump valve assy to AMC-3000 control box. Connect air lines to dump valve assembly.

Step 23. Wire water solenoid valve (item 7) to AMC-3000 control box as shown.

23

4

4

5

7

6

Air Lines To Air

Regulator Assy.

28 AMC / TDS OPERATOR’S MANUAL

#8.913-965.0 • REV. 4/13

DUMP VALVE INSTALLATION INSTRUCTIONSAMC-1000/AMC-3000

Step 1. Disconnect hose and move sludge tub away from drain valve at the bottom of the cone tank.

Step 2. Unscrew hose barb from drain valve.

AMC-3000 Models Only

Step 3. Attach dump valve assembly. Reconnect sludge tub to dump valve assembly as shown.

Step 4. Install water solenoid valve as shown (AMC-3000 only).

4

5

7

5

6

2

12

3

ITEM PART NO. DESCRIPTION 1 6-140166 Solenoid, Water Maze, PVC 24V

2 2-10811 Bushing, 1" x 1/2" Pipe

3 2-0100399 Nipple, 1/2", PVC 80 Close

4 2-011081 Pipe, 2", Gray, PVC 80

ITEM PART NO. DESCRIPTION 5 2-0100386 Adapter, 2" Slip x MT, PVC 80

6 6-050429 Valve, GEMU Silverline, Threaded Ends & 2 Female

7 6-050431 Solenoid, Air, GEMU Type 322

8 2-0100437 Union, 2" FS x FT, PVC 80

Sludge Tub

Drain Valve

4

8

AMC / TDS OPERATOR’S MANUAL 29

#8.913-965.0 • REV. 4/13

Step 1. Place TDS-1000 control box onto railing as shown.

Water Panel (Front View)

Step 2. Wire rain water overflow valve and fresh water inlet valve to TDS-1000 box per wiring diagram.

Float For Optional

Storage Tank

TDS-1000 Control Box

Rain Water Overflow

Fresh Water Inlet

INSTALLATION INSTRUCTIONSTDS-1000

2

1

2

30 AMC / TDS OPERATOR’S MANUAL

#8.913-965.0 • REV. 4/13

CONTROL PANELAMC-2000/AMC-3000

AMC-3000 Models

Only

AMC-3000 Models Only

11

28

19

20

18

29

16

17

23

25

13

14

11

8

222

2411

312

6

7

21

5

7

10

9

7

1

4

2726

3015

631

AMC / TDS OPERATOR’S MANUAL 31

#8.913-965.0 • REV. 4/13

ITEM PART NO. DESCRIPTION QTY 1 8.716-281.0 Box, Plastic, 14" x 16" x 6.75" w/Hinged Lid 1

2 8.913-206.0 Standoff, Electric Box 1

3 8.900-264.0 Label, AMC System 1

4 9.803-652.0 Light, Indicator, Green 28V 4

5 8.716-078.0 Switch, Toggle, 1-1/2" HP, 1 Pole, P3CA201-73 1

6 9.802-759.0 Screw, 10/32" x 1/2" BHSOC Blk 4

7 9.802-791.0 Nut, Cage, 10/32" x 16 GA 6

8 9.802-457.0 Din Rail, 35mm, /in. 6

9 9.802-467.0 Base, Relay, SH2B-05, IDEC 3

10 8.716-230.0 Relay, 24V, Finder 3

11 9.802-695.0 Nut, 10/32" KEPS 4

12 8.716-414.0 Block, Terminal, 23 Pole 1

13 8.751-306.0 Timer, Multi-Function, 24V-120/240V 1

14 8.716-439.0 Controller, Automatic Maintenance (As of 1/02) 1

15 8.718-967.0 Washer 3

16 8.900-263.0 Label, Backwash Controller 1

17 8.724-267.0 Contactor, 15 Amp 1

18 8.716-883.0 Transformer, Micron, 208/230/ 460V-24/115V, .050KVA 1

CONTROL PANEL PARTS LISTAMC-2000/AMC-3000

ITEM PART NO. DESCRIPTION QTY 19 8.933-007.0 Fuse, KTK-R1 600V Midget 2

20 8.716-142.0 Switch, Float, N/O, .20 PMDWOP, 1003825 (Black) 1

21 9.802-525.0 Locknut, 1/2" 8463 8

22 9.802-515.0 Strain Relief, STRT, LQ Tite 3200 10

23 8.716-460.0 Terminal, Grounding Lug, LAMA6-14-Q 1

9.800-040.0 ▲ Label, Ground 1

24 9.802-762.0 Screw, 10/32" x 1-1/4" RH, SL, Blk 1

25 9.802-494.0 Bar, Jumper 11

26 8.716-083.0 Plate, ON/OFF 1

27 8.716-081.0 Protector, Cover, Toggle Switch 1

28 8.900-421.0 Label, Control Panel (AMC-3000) 1

8.940-168.0 Label, Control Panel (AMC-2000) 1

29 9.803-977.0 Fuse, 2-1/2" Amp, 250V, FNM2-1/2 1

30 8.718-936.0 Tek Screw 4

31 8.900-714.0 Tag, Warning, Filter Pump Contactor Wiring 1

▲ Not Shown

32 AMC / TDS OPERATOR’S MANUAL

#8.913-965.0 • REV. 4/13

CONTROL PANELAMC-1000/TDS-1000

35

29

30

32

28

2827

25

26

31

33

34

7

53 21,22,23

1

42

8

14

12

11

TDS-1000 Only 9

16

10

813

17

6

TDS-1000 Units Only

15

18

19

20

38

37

AMC-1000 Units Only

AMC-1000 Units Only

36

24

8

39

AMC / TDS OPERATOR’S MANUAL 33

#8.913-965.0 • REV. 4/13

CONTROL PANEL PARTS LISTAMC-1000/TDS-1000

ITEM PART NO. DESCRIPTION QTY 1 8.716-272.0 Box, 12" x 10" x 5-1/4", Separator 1

2 8.716-081.0 Protector, Cover, Toggle Switch 1

3 8.716-078.0 Switch, Toggle, 1-1/2" HP, 1 Pole P#CA201-73 1

4 8.716-083.0 Plate, On/Off 1

5 9.802-455.0 Light, Indicator, Green 125V 1

6 9.802-515.0 Strain Relief, STRT, LQ Tite 3231 Small 3

7 9.802-525.0 Locknut, 1/2" 8463 3

8 8.718-936.0 Screw, #8 x 1/2", Tek Sq. Head, SS 8

9 9.802-493.0 Block, Terminal, 16 Pole (TDS-1000) 1

9.802-492.0 Block, Terminal, 8 Pole (AMC-1000) 1

10 8.751-306.0 Timer, Multi-Function, 24V-120/240V 1

11 9.802-468.0 Relay, 120V, RH2B-UL-AC120 2

12 9.802-467.0 Base, Relay, SH2B-05, IDEC 2

13 9.802-457.0 Din Rail, 6 in. 1

14 8.716-253.0 Timer, 24 Hour Pin, 120V 20A 1

15 8.716-143.0 Switch, Float, N/C 1003826 (Gray) 1

16 9.802-749.0 Screw, 8/32" x 3/4" 2

17 8.920-278.0 Plate, Mount, Control Panel 1

8.716-460.0 ▲ Lug, Terminal Ground 1

9.800-040.0 ▲ Label, Ground 1

18 8.912-138.0 Bracket Electrical Box, 12 GA MS, TDS System 1

19 8.900-420.0 Label, TDS Control Panel 1

8.940-169.0 Label, AMC-1000 Control Panel 1

20 8.933-007.0 Fuse, 1 Amp, Primary (AMC-1000) 2

21 8.718-603.0 Bolt, 1/4" x 3/4", NC HH SS 4

22 8.718-817.0 Nut, 1/4" - 20, Hex Whiz Loc, SS 4

ITEM PART NO. DESCRIPTION QTY 23 8.718-965.0 Washer, 1/4" SS, Flat 4

24 9.802-785.0 Nut, 8/32" Keps 2

25 8.707-177.0 Nipple, 1/4" MAL AIR (AMC-1000) 1

26 8.707-331.0 Regulator, Air w/Filter, 1/4" Gauge (AMC-1000) 1

27 8.706-777.0 Nipple, 1/4" Close, P/N-3326-4 (AMC-1000) 1

28 8.706-915.0 Bushing, 1/2" x 1/4" Brass (AMC-1000) 2

29 9.802-961.0 Hose Connection Bracket (AMC-1000) 1

30 8.706-958.0 Hose Barb, 1/4" Barb x 1/4" Pipe, 90° (AMC-1000) 1

31 6.390-126.0 Clamp, Hose, UNI .46 - .54 1

32 8.900-210.0 Label, Warning, 100 PSI Air Pres. (AMC-1000) 1

33 8.718-621.0 Bolt, 5/16" x 1", HH, NC, SS (AMC-1000) 2

34 8.718-980.0 Washer, 5/16", Flat, SAE (AMC-1000) 2

35 8.718-887.0 Nut, 5/16", SS, Whiz Loc (AMC-1000) 2

36 9.802-494.0 Bar, Jumper 1

37 9.802-553.0 Transformer, 120/240-24V, .050 KVA (AMC-1000) 1

38 9.803-977.0 Fuse, 2.5 Amp, Secondary (AMC-1000) 1

39 9.802-455.0 Light Indicator, Green, 125V (TDS-1000) 1

9.803-652.0 Light, Indicator, Green 28V 1

34 AMC / TDS OPERATOR’S MANUAL

#8.913-965.0 • REV. 4/13

EXPLODED VIEWAMC-2000/AMC-3000

To Filter Pump

For Detail See Control Panel Illus.

To Carbasorb Filter Inlet

To Multi-Media Filter Inlet

To Storage Tank #2

To Main Drain Line

To Multi-Media Filter Outlet

AMC-2000 Models Only

2

12

347

8

37

34

86 5

5

9

377

7

9

10

9 10

4411

7

117

3811 7

7

10

37

7

20

20,41

20

778

7

37

21

21

21

21

26

25

22

7

7

37

22

7

7

29

31

30

32

3334

2423

33

15

3536 35

1528

2324

20

39

40

7

37

3711

79

742

6

7

53

16

17

77

10

19

18

12

13

14

15

7

48

21

27

7

50 43

15 14

20

46

4745

4546

45

47

45

AMC-3000 Models Only

51

52

To Carbasorb Filter Outlet

54

57

56

55

58

AMC / TDS OPERATOR’S MANUAL 35

#8.913-965.0 • REV. 4/13

EXPLODED VIEW PARTS LISTAMC-2000/AMC-3000

ITEM PART NO. DESCRIPTION QTY 1 8.716-697.0 Solenoid, Water Maze, PVC 24V1

2 8.706-439.0 Nipple, 1", PVC 80, Close 2

3 8.706-378.0 Elbow, 1" SLIP X FIPT, PVC 80, 90° 2

4 8.706-597.0 Union, "1, S x S, PVC 80 Spears 2

5 8.706-431.0 Tee, 1-1/2" x 1-1/2" x 1" SLIP, PVC 80 2

6 8.707-344.0 Valve, PVC 1.5" SLIP x SLIP, Gate 2

7 8.706-374.0 Elbow, 1-1/2" SxS, PVC 80, 90° 24

8 8.706-469.0 Union, 1-1/2" SLIP x SLIP, PVC 80 Spears 3

9 8.716-424.0 Valve, 3 Way Ball Assembly 4

10 8.706-426.0 Tee, 1.5" S x S x S, PVC 80 4

11 8.706-441.0 Adapter, 1.5" x 1.5" FT x SLIP, PVC 80 4

12 8.706-857.0 Tee, 1/8" Street 3

13 8.706-940.0 Hose Barb, 1/4" Barb x 1/8"ML Pipe 3

14 8.706-955.0 Hose Barb, 1/4" Barb x 1/8" ML Pipe, 90° 4

15 6.390-126.0 Clamp, Hose, UNI .46 - .54 7

16 8.716-157.0 Protector, Pressure Switch, 3302-001 1

17 8.716-158.0 Switch, Pressure, 15 PSI 1

18 8.706-914.0 Bushing, 1/2" x 1/8" Pipe 1

19 8.706-406.0 Bushing, 1-1/2" x 1/2" SPG x FT, PVC 80 1

20 8.706-470.0 Union, 1-1/2" SLIP x Thread PVC 80 Spears 4

21 8.706-424.0 Nipple, 1.5" x Close, PVC 80 8

22 8.718-887.0 Nut, 5/16", SS Whiz Loc 6

23 8.718-621.0 Bolt, 5/16" x 1", HH, NC, SS 6

24 8.718-980.0 Washer, 5/16", Flat, SAE 6

25 8.900-461.0 Label, Return 1

26 8.900-530.0 Label, Tank 2, Clar., Lexan 1

27 8.900-454.0 Label, Carbasorb Filter 1

28 8.900-210.0 Label, Warning, 100 PSI Air Pressure 1

ITEM PART NO. DESCRIPTION QTY 29 8.706-421.0 Hanger, Pipe, 1-1/2" Click #47 4

30 8.707-177.0 Nipple, 1/4" Mal Air 1

31 8.707-331.0 Regulator, Air w/Filter, 1/4" Gauge 1

32 8.706-777.0 Nipple, 1/4" Close 1

33 8.706-915.0 Bushing, 1/2" x 1/4" Brass 2

34 9.802-961.0 Hose Connection Bracket 1

35 8.706-958.0 Hose Barb, 1/4" Barb x 1/4" Pipe, 90° 2

36 8.706-854.0 Tee, 1/4" Branch 1

37 8.711-815.0 Hose, 1-1/2" Gray Conduit /ft. 50

38 8.706-360.0 Pipe, 1.5" PVC Clear 10"

39 8.912-139.0 Panel, Manifold, AMC 1

40 8.900-451.0 Label, Multi-Media Filter 1

41 8.706-424.0 Nipple, 1.5" Close PVC, SCH. 80 4

42 8.706-360.0 Pipe, 1.5" PVC Clear 13.25"

43 8.706-360.0 Pipe, 1.5" PVC Clear 9.75"

44 8.706-360.0 Pipe, 1.5" PVC Clear 15"

45 8.706-367.0 Pipe, 1.5" PVC SCH. 80 (9.75") 4

46 8.706-367.0 Pipe, 1.5" PVC SCH. 80 (18") 2

47 8.706-367.0 Pipe, 1.5" PVC SCH. 80 (6") 2

48 8.706-360.0 Pipe, 1.5" PVC Clear SCH. 80 3.25"

49 4-02100000 ▲ Hose, 1/4", Air Line 12 ft.

50 8.706-387.0 Plug, 1/2" 1

51 8.900-710.0 Tag, Carbasorb Outlet Port, AMC 1

52 8.900-709.0 Tag, Carbasorb Inlet Port, AMC 1

53 8.900-707.0 Tag, Multi-Media Inlet Port, AMC 1

54 8.900-708.0 Tag, Multi-Media Outlet Port, AMC 1

55 8.900-711.0 Tag, Filter Pump Inlet, AMC 1

56 8.900-713.0 Tag, Backwash Return, AMC 1

57 8.900-712.0 Tag, Tank #2 Inlet, AMC 1

58 8.706-787.0 Bulkhead, 1-1/2" 4

▲ Not Shown

AMC / TDS OPERATOR’S MANUAL 37

#8.913-965.0 • REV. 4/13

WATER MAZE LIMITED NEW PRODUCT WARRANTYWASH-WATER SYSTEMS

WHAT THIS WARRANTY COVERSAll WATER MAZE wash-water systems are warranted by WATER MAZE to the original purchaser to be free from defects in materials and workmanship under normal use, for the periods specified below. This Limited Warranty, subject to the exclusions shown below, is calculated from the date of the original purchase, and applies to the original components only. Any parts replaced under this warranty will assume the remainder of the part’s warranty period. A 60 day grace period will be given for installation.

ONE YEAR PARTS AND 30 DAY LABOR WARRANTY:All components excluding normal wear items as described below.

WARRANTY PROVIDED BY OTHER MANUFACTURERS:Motors, which are warranted by their respective manufacturers, are serviced through these manufacturers’ local authorized service centers. WATER MAZE cannot provide warranty on these items.

NON-WARRANTY REPLACEMENT PARTS:These parts, excluding normal wear items as described below, will be warranted for the duration specified by the original com-ponent manufacturer. O-rings and leaks at glued fittings are covered the first time on original start-up only.

WHAT THIS WARRANTY DOES NOT COVERThis warranty does not cover the following items:

1. Normal wear items, such as mechanical seals, filters, gaskets, O-rings, check valves, filtering media, ozone bulbs. O-rings and leaks at glued fittings are covered the first time on original start-up only.

2. Damage or malfunctions resulting from accidents, abuse, modifications, alterations, incorrect installation, improper servicing, failure to follow manufacturer’s maintenance instructions, or use of the equipment beyond its stated usage specifications as contained in the operator’s manual.

3. Damage due to freezing, chemical deterioration (oxidation, chloride or fluoride corrosion).4. Damage to components from fluctuations in electrical or water supply.5. Normal maintenance service, including adjustments.6. Transportation to service center, field labor charges, or freight damage. 7. Death of microbes (Biostax 900 & 100) from lack of refrigeration after received and stored.

WHAT YOU MUST DO TO OBTAIN WARRANTY SERVICEWhile not required for warranty service, we request that you register your WATER MAZE Product by returning the completed registration card. In order to obtain warranty service on items warranted by WATER MAZE, you must return the product to your Authorized WATER MAZE Dealer, freight prepaid, with proof of purchase, within the applicable warranty period. If the product is permanently installed, you must notify your Authorized WATER MAZE Dealer of the defect. Your Authorized WATER MAZE Dealer will file a claim with WATER MAZE, who must subsequently verify the defect. In most cases, the part must be returned to WATER MAZE freight prepaid with the claim. For warranty service on components warranted by other manufacturer’s, your Authorized WATER MAZE Dealer can help you obtain warranty service through these manufacturers’ local authorized service centers.

LIMITATION OF LIABILITYWATER MAZE’S liability for special, incidental, or consequential damages is expressly disclaimed. In no event shall WATER MAZE’S liability exceed the purchase price of the product in question. WATER MAZE makes every effort to ensure that all illustrations and specifications are correct, however, these do not imply a warranty that the product is merchantable or fit for a particular purpose, or that the product will actually conform to the illustrations and specifications. THE WARRANTY CONTAINED HEREIN IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF FITNESS FOR THE PARTICULAR PURPOSE, INCLUDING QUALITY OF WATER TREATMENT. WATER MAZE does not au-thorize any other party, including authorized WATER MAZE Dealers, to make any representation or promise on behalf of WATER MAZE, or to modify the terms, conditions, or limitations in any way. It is the buyer’s responsibility to ensure that the installation and use of WATER MAZE products conforms to local codes. While WATER MAZE attempts to assure that its products meet national codes, it cannot be responsible for how the customer chooses to use or install the product.

WATER MAZEwww.wmaze.com • 1-360-833-2333 • 1-800-535-0941

Form #8.913-965.0 • Revised 4/13 • Printed in U.S.A.