Page 1: Operation of the FW-720 Unit 1. Side 1 2 Inlet Hand Crank

1Operation of the FW-720 Unit

Page 2: Operation of the FW-720 Unit 1. Side 1 2 Inlet Hand Crank

2

Side 1

Inlet

Hand Crank

Page 3: Operation of the FW-720 Unit 1. Side 1 2 Inlet Hand Crank

3

Side 2In

let

Discha

rge

Pump

Ball Valve

75 psi Pressu

re

Relief V

alve

Female

GHT

Inlet

Flow Restrictor

Page 4: Operation of the FW-720 Unit 1. Side 1 2 Inlet Hand Crank

4

Side 3

Removable Pump

Page 5: Operation of the FW-720 Unit 1. Side 1 2 Inlet Hand Crank

5

Side 4

Air Bleed Valve

Lamp out Solenoid

Page 6: Operation of the FW-720 Unit 1. Side 1 2 Inlet Hand Crank

6

PumpIntake Hose

(Could be a standard garden hose)

Pump

Discharge Hose

Page 7: Operation of the FW-720 Unit 1. Side 1 2 Inlet Hand Crank

7

Canisters and Filters

Canisters

Filters UV Bulb

Page 8: Operation of the FW-720 Unit 1. Side 1 2 Inlet Hand Crank

8Additional Components

Extension Cords Discharge Hose

Operation Manual

Canister WrenchQuick Setup Guide

Spare Quartz Sleeve or UV Bulb

Page 9: Operation of the FW-720 Unit 1. Side 1 2 Inlet Hand Crank

9Setup from Static Water Source

Source Water

Pump

Purification Unit

- Pump must be Primed -Remove Plug and Fill with Water

Page 10: Operation of the FW-720 Unit 1. Side 1 2 Inlet Hand Crank

10Setup – Directly From Building

Simply connect hose and turn water on

Page 11: Operation of the FW-720 Unit 1. Side 1 2 Inlet Hand Crank

11

Preparing the Unit• Make sure all canisters have new, clean filters in them• Disinfect all discharge outlets and hoses with a bleach / water

solution• A ¼ cup to 1 gallon of water solution is generally a good ratio

but use the ratio that is appropriate for your facility. Let sit in bleach water for 2 minutes.

Page 12: Operation of the FW-720 Unit 1. Side 1 2 Inlet Hand Crank

12

Priming the Pump• Prime pump

• Open priming plug and fill pump with water• Fill intake hose completely with water• Place foot valve into water source and

connect other end of hose to pump intake• Plug pump in to power source• Wait for pump to turn on and see if the

pump is primed.• If pump is not primed or loses the prime

repeat the above process until pump stays primed.

• Once pump is primed unplug pump to turn off then connect hose to pump discharge and the other end to the FW-720 intake.

Priming Plug

Drain Plug

Page 13: Operation of the FW-720 Unit 1. Side 1 2 Inlet Hand Crank

13

Turning the FW-720 On

• Once the FW-720 intake hose is connected, plug the UV power cord in.

• The blue lamp on the power supply should light up indicating the lamp is on.

Note:This picture shows the UV bulb illuminated. When in actual use the UV bulb will not be visible because it is inside a black canister.

Warning:Exposure to UV light can cause skin and eye damage. Do not look directly at the UV bulb.

Page 14: Operation of the FW-720 Unit 1. Side 1 2 Inlet Hand Crank

14

Flowing the FW-720

• Make sure a hose is connected to the FW-720 discharge outlet

• Plug the pump in to turn it on• Open the intake ball-valve• Allow water to flow for a minute to flush any debris out of

the system and hoses.

Page 15: Operation of the FW-720 Unit 1. Side 1 2 Inlet Hand Crank

15

Cleaning the FW-720• Turn unit off by unplugging the pump and the UV power supply• Disconnect all connections• Remove screen filter canister from pump. Rinse and clean screen filter. Drain and

dry canister.• Remove the drain and priming plug from pump . Allow water to fully drain from the

pump. Tilting the pump back and forth and side to side helps remove all water.• Replace drain plugs and screen filter after pump has drained.• Remove all filter canisters; remove and discard used filters; dry out the inside of the

canisters.• Open the intake ball valve and the air bleed valve. Tilt the unit back and forth until

the unit drains. If possible, allow the unit to air dry several days before replacing canisters.

• Drain hoses• Store the unit with no filters installed. Filters will be installed before the next use.• Clean the unit as good as possible. The unit can be disinfected at your discretion but

is not required. Disinfecting the unit is always done before it is used.

Page 16: Operation of the FW-720 Unit 1. Side 1 2 Inlet Hand Crank

16Preventative Maintenance

• Plug the UV power supply in and make sure the bulb is working

• Remove canisters and make sure the O-rings are still lubricated

Every 6 months:

• Make sure all parts and hoses are with the unit and haven’t been lost or repurposed.