operating room light with stand yde500d
TRANSCRIPT
Operating Room Light With StandYDE500D
Mobile Surgical LightRead More
SKU:
Price:
Categories: Surgery
Product Description
Model:YDE500DType: mobile/ portable/ floor/ standing type surgical light (operating room light)surgical material: German Osram LED beads, German ONDAL balance armillumination: 120,000-160,000 luxbattery optional ( 3hours)color temperature: 3500-5500Krender index: 96Rahead diameter: 500mm ( 19.7'' inches)whole weight: 40kg(88 lbs)CE, ISO9001, NQA, FDA Class II
Heavy Duty Suction Machine TR7A-23D
Electrical Heavy Duty Suction Machine
Read More
SKU:
Price:
Categories: Surgery
Product Description
1. Complete plastic panels, hand-switch and foot-switch for operating easily. Select negative pressure at willwith no level for pressure adjustment, and overflow protection mechanism, safe and reliable;2. Negative pressure: 0.02-0.09MPa;
3. Air pumping efficiency: ?20L/min;4. Glass bottle: 2500ml×2.
Heavy Duty Suction Machine TR7A-23B
Electrical Heavy Duty Suction MachineRead More
SKU:
Price:
Categories: Surgery
Product Description
1. It adopts completely plastic panel design2. The device of intercepting oil for circumfluence can reduce the oil pollution3. Hand-switch and foot-switch for operating easily.4. Negative pressure: 0.02-0.09MPa5. Noise:?65dB (A)6. Power:?180VA7. Pumping rate: ?20L/min8. Reservoir capacity: 2500mL/pc, 2pieces9. Power Voltage: AC220V±22V,50Hz±1Hz
Operating Lamp Ceiling MountedYDE500/700
Operating Light Double DomeRead More
SKU:
Price:
Categories: Surgery
Product Description
Model: YDE500/700Name: Ceiling mounted portable operating lampManufacture: YUDAillumination: 120,000-190,000 luxcolor temperature: 3500-5500kRa: 97LED beads type: German OsramGerman Ondal balance arm, 360° rotation for doctors using.Strong and mature technology on the shadow dissolve.Endoscopy standard.with 4 free sterile and strong after service and technical support.
Syringe Pump DS-3000
MEDIFUSION Syringe PumpRead More
SKU:
Price:
Categories: Surgery
Product Description
FEATURES
Flow rate : 0.1~1500 ml/hInfused Volume : 0.1~9999 mlBolus rate : 1~1500 ml/hK.V.O : 0.1~9 ml/hOcculsion Level : 9 Level (60-850 mmHg)Battery : Operating 6 hour, Recharging 5 hourWeight : 1.8 kg
Pumping Mechanism Peristaltic Transit Finger
Flow Rate 0.1 ~ 1200 ml/h
Micro (On): 0.1 ~ 999.9 ml/h (in 0.1ml/h increments) 1000 ~ 1200 ml/h(in 1 ml/h increments) Micro (Off): 1 ~1200 ml/h (in 1 ml/h increments)
Accuracy
±5% (BD I.V Set, AN122) Measured every hour at room temperature(25?) using water or saline solution (above 1.0 ml/h of flow rate). *Accuracy may differ depending on the type of medical fluid and IV Set& Feeding Set.
Infusion Range Total Vol. 0.1 ~ 9999 ml or infinity
Micro (On): 0.1 ~ 999.9 ml (in 0.1 mlincrements) 1000 ~ 1200 ml (in 1 mlincrements) Micro (Off): 1 ~ 9999 ml(in 1 ml increments)
Infused Vol. 0.0 ~ 9999 ml0.0 ~ 999.9 ml (in 0.1 mlincrements)1000 ~ 9999 ml (in1 ml increments)
Bolus Rate (Purge) 700 ml/h (default) - 1 ~ 1200 ml/h
Bolus Volume (Purge) 5 ml (default) - 1 ~ 9999 ml
KVO Rate1 ml/h (default) 1 ~ 9 ml/h At flow rate 1.0 ~ 1200 ml/h
0.1 ml/h (default) At flow rate 0.1 ~ 0.9 ml/h
Occlusion pressure 100mmHg ~ 950mmHg(13~126kPa)
Display 7 segments (4 digits * 3 lines)
Alarms
* Air Bubble alarm * Occlusion alarm (detection capacity: 100 ~ 950mmHg) - 9 adjustable steps for downstream occlusion * Door Openalarm * Battery Low, Battery Empty alarm * Abnormal Drop alarm *Infusion Complete alarm (automatic switch-over to KVO feature) *AC/DC Power Shut-off alarm * Start Reminder alarm (pause set timeelapsed) * Standby alarm (at an interval of 2 minutes when notinfusing) * Near complete alarm * The pump stops operating whenalarms go off except for battery low, start reminder and infusioncompletion signals. * Malfunction - The status of the pump is displayedand an alarm goes off.
Safety Features
* Door Open: Infusion is unavailable when the door is open. * KeyLock: Only the START, STOP and ON/OFF keys work. * Air Sensor:Detects air bubbles. * Occlusion Sensor: Detects clogging of the tube.* Drop Sensor: Detects medical fluid drops. * Nurse Call: Monitoring ispossible if an alarm goes off.
Other Functions
* Time Mode: Calculates the flow rate by setting the infusion time. * GttMode: Calculates the flow rate by setting the number of infusion drops.* Dosage Mode: Calculates the flow rate by setting the dosage. *Titration: Flow rate can be altered during infusion (available only whenthe remaining time for infusion is more than 5 minutes). * Battery Low,Empty: Alarms go off 30 minutes and 3 minutes before the batterygoes flat. * Date and Time: The date and time can be checked withouta power supply, since a clock is installed. * Pause: Infusion resumesautomatically after preset time elapses when the pause key is pressedand infusion is stopped (default 24 hours, setting range from 1 minuteto 24 hours in 1 minute units). * Event History: Saves up to 2000 and itcan view by separate PC utility. Please refer service manual fordetailed usage of event history. * Alarm log event: Saves up to 50 inthe pump and it can view in the pump at setting mode1. Please referservice manual for detailed usage of alarm log event. * The electronicdata of the infusion pump are stored for over 2 years even if it hasbeen turned off.
Power
* AC 100~240 VAC, 50/60 Hz (Fuse: 250 V, T3.15 A) * DC 12V (500mA) * Ni-MH Rechargeable Battery - 2,000 mA/h, AA, 1.2V x 10cell -operating time – approx. 6 hours at a flow rate of 25 ml/h - rechargingtime – approx. 5 hours
Power Requirements 35VA
Protection Type* Protection from electric shock: Class ? * Protection capacity forelectric shock: Type CF Protection from liquid infiltration: IPX 2 (drip-proof)
Size (D×W×H) 120×130×206 mm
Weight approx. 1.7 kg
Operating EnvironmentTemperature: 10~ 40?, Humidity: 20 ~ 90% RH Atmospheric Pressure:70 ~ 106 kPa (525.04 ~ 795.06 mmHg)
Storage EnvironmentTemperature: -10 ~ 60?, Humidity: 10 ~ 95% Atmospheric Pressure:65 ~ 120 kPa (487.54 ~ 900.07 mmHg)
Infusion Pump DI-2000
MEDIFUSION Volumetric Infusion PumpRead More
SKU:
Price:
Categories: Surgery
Product Description
FEATURES
Compact DesignSmall size - 1.7kgCompatible with various kinds of IV setBrdad range of flowrate : 0.1 to 1,299 ml/hOne touch Bolus, Pause functionDosage-auto calculation (Input data : boby weight, drug volume, Solution volume, dose rate)Titration - Enable to change the flowrate during infusionKeylock for safetyEvent history up to 2000Firmware upgrade via internet (system or software upgrade)Quality Assurance & Certification - ISO13485, CE
Pumping Mechanism Peristaltic Transit Finger
Flow Rate 0.1 ~ 1200 ml/h
Micro (On): 0.1 ~ 999.9 ml/h (in 0.1ml/h increments) 1000 ~ 1200 ml/h(in 1 ml/h increments) Micro (Off): 1 ~1200 ml/h (in 1 ml/h increments)
Accuracy
±5% (BD I.V Set, AN122) Measured every hour at room temperature(25?) using water or saline solution (above 1.0 ml/h of flow rate). *Accuracy may differ depending on the type of medical fluid and IV Set& Feeding Set.
Infusion RangeTotal Vol. 0.1 ~ 9999 ml or infinity
Micro (On): 0.1 ~ 999.9 ml (in 0.1 mlincrements) 1000 ~ 1200 ml (in 1 mlincrements) Micro (Off): 1 ~ 9999 ml(in 1 ml increments)
Infused Vol. 0.0 ~ 9999 ml0.0 ~ 999.9 ml (in 0.1 ml increments)1000 ~ 9999 ml (in 1 ml increments)
Bolus Rate (Purge) 700 ml/h (default) - 1 ~ 1200 ml/h
Bolus Volume (Purge) 5 ml (default) - 1 ~ 9999 ml
KVO Rate1 ml/h (default) 1 ~ 9 ml/h At flow rate 1.0 ~ 1200 ml/h
0.1 ml/h (default) At flow rate 0.1 ~ 0.9 ml/h
Occlusion pressure 100mmHg ~ 950mmHg(13~126kPa)
Display 7 segments (4 digits * 3 lines)
Alarms
* Air Bubble alarm * Occlusion alarm (detection capacity: 100 ~ 950mmHg) - 9 adjustable steps for downstream occlusion * Door Openalarm * Battery Low, Battery Empty alarm * Abnormal Drop alarm *Infusion Complete alarm (automatic switch-over to KVO feature) *AC/DC Power Shut-off alarm * Start Reminder alarm (pause set timeelapsed) * Standby alarm (at an interval of 2 minutes when notinfusing) * Near complete alarm * The pump stops operating whenalarms go off except for battery low, start reminder and infusioncompletion signals. * Malfunction - The status of the pump is displayedand an alarm goes off.
Safety Features
* Door Open: Infusion is unavailable when the door is open. * KeyLock: Only the START, STOP and ON/OFF keys work. * Air Sensor:Detects air bubbles. * Occlusion Sensor: Detects clogging of the tube.* Drop Sensor: Detects medical fluid drops. * Nurse Call: Monitoring ispossible if an alarm goes off.
Other Functions
* Time Mode: Calculates the flow rate by setting the infusion time. * GttMode: Calculates the flow rate by setting the number of infusion drops.* Dosage Mode: Calculates the flow rate by setting the dosage. *Titration: Flow rate can be altered during infusion (available only whenthe remaining time for infusion is more than 5 minutes). * Battery Low,Empty: Alarms go off 30 minutes and 3 minutes before the batterygoes flat. * Date and Time: The date and time can be checked withouta power supply, since a clock is installed. * Pause: Infusion resumesautomatically after preset time elapses when the pause key is pressedand infusion is stopped (default 24 hours, setting range from 1 minuteto 24 hours in 1 minute units). * Event History: Saves up to 2000 and itcan view by separate PC utility. Please refer service manual fordetailed usage of event history. * Alarm log event: Saves up to 50 inthe pump and it can view in the pump at setting mode1. Please referservice manual for detailed usage of alarm log event. * The electronicdata of the infusion pump are stored for over 2 years even if it hasbeen turned off.
Power
* AC 100~240 VAC, 50/60 Hz (Fuse: 250 V, T3.15 A) * DC 12V (500mA) * Ni-MH Rechargeable Battery - 2,000 mA/h, AA, 1.2V x 10cell -operating time – approx. 6 hours at a flow rate of 25 ml/h - rechargingtime – approx. 5 hours
Power Requirements 35VA
Protection Type* Protection from electric shock: Class ? * Protection capacity forelectric shock: Type CF Protection from liquid infiltration: IPX 2 (drip-proof)
Size (D×W×H) 120×130×206 mm
Weight approx. 1.7 kg
Operating EnvironmentTemperature: 10~ 40?, Humidity: 20 ~ 90% RH Atmospheric Pressure:70 ~ 106 kPa (525.04 ~ 795.06 mmHg)
Storage EnvironmentTemperature: -10 ~ 60?, Humidity: 10 ~ 95% Atmospheric Pressure:65 ~ 120 kPa (487.54 ~ 900.07 mmHg)
Surgical Cautery Machine DT-400S
MEDITOM Electro Surgical Cautery MachineRead More
SKU:
Price:
Categories: Surgery
Product Description
FEATURES
New digital displayDRM(Daiwha Return Electrode Monitoring System)Automatic shutdown circuit when over current
Purpose Cutting or coagulation of biological tissue using high-frequency current Mains and Line Frequency120(60Hz) or 230VAC (±10%) (50 or 60Hz)/switchable See the label on rear side for correct information Fuses Two of F5.0A, 250V for 230VAC Two of F10.0A, 250V for 115 VAC Power Consumption 900VA Protection Class Class 1, Type CF IPX Foot Switch: IPX6 Carrier Frequency 400 KHz ±10%, 482KHz ±10% Repeat Frequency 33KHz Low Freq. Leakage Current EN60601-1 [2012] Requirement High Freq. Leakage Current Less than 150mA Operation Conditions 10??40?, 30%? 85? noncondensing, 700mbar?1060mbar Storage Conditions -10??60?, 30%? 95? noncondensing, 700mbar?1060mbar Transportation Conditions -10??60?, 30%? 95? noncondensing, 700mbar?1060mbar Do not drop the unit from higher than 50cm Do notuse the hook. Installation Conditions 5cm clearance required on each side unit for cooling Cooling 1 fanmounted Recommended Duty Cycle 10 sec ON, 30 sec, OFF (Output for 10 seconds, pause for 30 seconds) Size (H, W, D) 147mmx 330mm x 417mm Weight About 16Kg APG Not AP/APG device Equipment notsuitable for use in the presence of a flammable anesthetic mixture with or with oxygen or nitro oxide Operation Sound Difference in operation sounds between cutting and coagulation. Operation Display Visibledifference in operations between cutting and coagulation. Output Setting Displayed in [W] unit from SevenSegment (LED number displayer) (DT-400S) Tolerance: ±20%
ModeCarrier Frequency
(?)Repeat Frequency
(?)Output RF Power
(W)Load Resistance (?)
Pure mode 400 - 400 500
Blend1 mode 400 33 320 300
Blend2 mode 400 33 240 300
Blend3 mode 400 33 160 300
Forced mode 400 33 120 300
Soft mode 400 33 120 300
Spray mode 400 33 100 500
Cut mode 482 - 100 200
Standard mode 482 - 100 100
Soft mode 482 - 80 100
Electric Operation Table TRDT-12FM
Multi-purpose Electric Operation TableRead More
SKU:
Price:
Categories: Surgery
Product Description
1. Longitudinally movement more than 350mm, which can fulfill the needs of C type arm whole bodyexamination;2. Table width: 540mm;3. The leg board can be extension 180°,folded 90°and detached;4. The wheels adjustment, table height adjustment, forward and backward tilting, left and right tilting,backboard folded are all controlled by linear motor;5. Accessories, guide rail, base shell and column shell all are made of stainless steel;6. The table is equipped Auto-Charge Device, It can keep the table being used when emergency power shutoff.
C-Arm Compatible Electric InterventionalImaging Operation Table JR-9000
C-Arm Compatible Electric Interventional Imaging OperationTableRead More
SKU:
Price:
Categories: Surgery
Product Description
C-Arm Compatible Electric Interventional Imaging Operation Table JR-9000 1. Integrated electric operating table With advanced production technology, engineers make it an art and perfect every detail. The base ismade of a large number of high quality 304 stainless steels that are completely solid and sturdy. 2. High quality Product is easy to operate,strong versatility,wide application ,material selection,workmanshipexcellent,quality reached the international level. 3. More Features Manual: fold on the headboard, built-inwaist bridge, leg board fold Electric: lifting, folding on the back plate, folding on the leg board, single left legfolding up and down, single right leg folding up and down, panning, leaning back and forth, left and righttilting, one button reset, "V" and revised version "V", etc. 4.Safe and reliable Battery available With footbrakes for easy control of the operating bed Product details
Table board material cabon fibre
Whole length 2500±10mm
Length of radiolucent board 1750±10mm
Length without material inspection 1200±5mm
Whole width 685±5mm
Width of radiolucent board 465mm
Thickness 40mm
X-ray absorption conefficient (aluminium equivalent) ?0.44mmAL
Max. loading 240kg
Horizontal movement manual
locking device electromagnetic locking
longitudinal movement manual
Move route 250±20mm
Locking device electromagnetic locking
Max.head protract 1880±20mm
Max.foot protract 1050±20mm
Vertical movement Electric
Min. Bed height from the ground 750±20mm
Max.Bed height from the ground 1100±20mm
Move route 350±20mm
average velocity 8mm/s
Bed surface shifting/Horizontal movement/Locking controllor
average velocity 8mm/s
Table body locking Electric
Big Four direction wheel free moving
Inner configurate DC24V Panasonic lead-acid battery
Single-phase Alternating Current 220VAC 50/60Hz
Input maximum power 300VA
Protective tube F5AL250V(5*20mm)
Standard accessories Memory foam mattress-1pcs Arm supports-1pairs
Operating Lamp Monitor Camera SystemCeiling Mounted New YDE500/700
Operating Lamp Monitor Camera System Double DomeRead More
SKU:
Price:
Categories: Surgery
Product Description
Operating Lamp Monitor Camera System
YUDA Medical-- the largest medical manufacture workshop in North China. Buy Operating lamp factories from YUDA. Every light used for surgical purposes must adhere to certain requirements in terms of luminance, color, and other variables. This buyer's guide highlights the main product features and the benefits they bring to the surgeon and the surgical team to help buyers make informed decisions and save time. Model: NEW YDE500/700Name: Ceiling mounted portable operating lamp monitor camera systemManufacture: YUDAillumination: 80,000-180,000 luxcolor temperature: 3500-5500kRa: 97LED beads type: German OsramGerman Ondal balance arm, 360° rotation for doctors using.Strong and mature technology on the shadow dissolve.Endoscopy standard.with 4 free sterile and strong after service and technical support.
Syringe Pump BD-5000
Syringe Pump Brand MeditechRead More
SKU:
Price:
Categories: Surgery
Product Description
Syringe Pump Model: BD-5000 technical specification: Maxim. Injection rate: 1500 ml/h (Different syringeshave different maximum rate) Applicable syringes: All brands of standard syringes: 5, 10, 20, 30 and 50 (60)ml Drug library: More than 20 drug names: Penicillin, Vancomycin, Pitocin, Insulin, Lidocaine, Heparin,Atropin, Dopamine, Epinephrine etc. Power supply: AC100-240V.50/60HZ Gross weight: ?3.0kg Battery:Rechargeable lithium polymer battery 7.4V, 1600mA working for 4 hours (5ml/h) after being fully chargedMax power consumption: 25VA Accumulated volume: 0.1~9999.9ml Injection accuracy: ±3% (after beingwell adjusted, up to ±2%) Injection increment: 0.1ml/h Preset range: 0.1~9999.9ml Classification: Class II,type BF Injection rate range: 5ml: 0.1ml/h---100ml/h 10ml: 0.1ml/h---200ml/h 20ml: 0.1ml/h---400ml/h 30ml: 0.1ml/h---600ml/h 50 (60) ml: 0.1ml/h---1500ml/h Bolus rate: 5ml: 100ml/h 10ml: 200ml/h 20ml:400ml/h 30ml: 400-600ml/h 50ml: 400-1500ml/h Alarm function: NEAR, OVER, OCCL., syringedisengaged, no AC power supply, low battery, serious low battery, error 1/2/3, preset volume alarmSelectable modes: 1. Rate Mode 2. Time Mode 3. Body Weight Mode Time mode: Volume limit: 0.1-999.9ml Time: 1-2000min Body weight mode: Body weight: 0.1?300kg Drug limit: 0.1?999.9mg Volumelimit: 0.1?999.9ml Dose: 0.1?9999.9(subject to unit, dosage, liquid, weight and syringe)Unit: mg/kg/h,ug/kg/min Occlusion value: 0.04Mpa-0.16Mpa KVO rate: Adjustable range: 0.1ml/h-5.0ml/h, choose “OFF” tocancel EMC: Meet the requirements of IEC60601-1-2(2007 version) Electrical safety: Meet the requirementsof EN60601-1:1990+A1:1993+A2:1995 Two CPU
Infusion Pump BD-8000
Infusion Pump Brand MeditechRead More
SKU:
Price:
Categories: Surgery
Product Description
Infusion Pump Model: BD-8000 technique specifications Infusion rate range: 1-2000ml/h Bolus rate:1000ml/h Double CPU monitoring board, door-free design Preset infusion range: 1-9999ml, Accumulatedvolume: 0.1-9999.9ml Classification: Class II, type BF Increment: 0.1, 1, 10, 100 and 1000 KVO rate: 1ml/h(KVO will occur after OCCL. Alarm) Infusion accuracy: ±3? (after being well adjusted, up to ±1%) Powersupply: Widescreen power switch(AC100-240V0),50Hz/60Hz, fuse, T 2AL 250V Battery: Rechargeablelithium polymer battery, 8.4V, when infusion pump is connected to AC power, the battery will start chargingautomatically Max power consumption: 25VA, it can work for more than 4 hours (25ml/h) after being fullycharged. Infusion modes: Rate Model, Time Mode, Body Weight Mode. Applicable infusion set: nationalstandard infusion set Applicable standards: GB/T191-2008, GB8368-2005, GB9706.1-2007, GB9706.27-2005, GB9969.1, GB/T14710-1993, YY0466-2003? Applicable Environmental condition: Environmentaltemperature:+5?--+40?, air pressure:(860-1060)hPa, relative humidity:20%-80% Displayed information: Flowrate, preset volume, accumulated volume, Battery capacity, AC power symbol, infusion completion,occlusion, air bubbles, bed No. and pressure value etc. Status indication information: Stop. Run, Bolus, KVOAlarm function: Over, occlusion, air bubbles, low pressure, installation error of infusion pipe, abnormal1,abnormal2, drops error and serious low battery. Air Bubble Detection: At the rate of 600ml/h, the smallestbubbles that can be detected are 0.005ml of volume Infusion Pressure: Maximum pressure is 300kPa;occlusion gate value is 39.2kPa-137.2kPa.The longest time to give occlusion alarm is 2 minutes at rate of25ml/h. And at rate of 5ml/h is 5 minutes. Weight: Less than 1.8kg Outer Shell Material: ABS Plastic
Patient Monitor PG M9000
Portable Multiparameter Patient/Cardiac MonitorRead More
SKU:
Price:
Categories: Surgery
Product DescriptionTechnical Specifications SIZE AND WEIGHT Size 318mm X 264mm X 152mm Weight 4.5kg DISPLAY 12.1”Color TFT-LCD Resolution 800 X 600 pixels or higher POWER SUPPLY Power Voltage AC 100-240V50/60Hz Power Imput ? 85VA Fuse: T1.6AL/250V, ?5X20 ( mm ) Safety class: Category I BATTERY Type:rechargeable Sealed Lead Acid cell, 12V/2.0AH Charge time: ? 10 hours ( 2 batteries for 20 hours )Operating time under normal use and full charge: ? 60 minutes ( 2 batteries for 120 minutes ) Operating timeafter the first alarm if low battery: 5-15 minutes THERMAL RECORD ( OPTION ) Method: thermal dot arrayPaper width: 50mm ( 1.97 in ) Paper Speed: 12.5/25/50 ( mm/sec ) Traces Maximum: 3 tracks SYSTEMOUTPUT Ethernet Network standard RJ45 socket RF Wireless LAN: 433MHz, 10mW ( option ) DefibrillationOutput: Option Video Output: Option ALARM Three Level: Low, medium and high Indication: Auditory andvisual Setup: Default and custom Silence: All alarms can be silenced Volume: 45~85 dB measured at 1meter TREND Store & review 168 hours trend data and trend maps Parameter option: HR, SpO2, NIBP, PR,Resp, CO2, Temp1, Temp2, AA, N2O, O2, IBP1, IBP2, ST. Cycle intervals of trend storage 1min, 2min,3min, 4min, 5min, 10min, 15min, 20min, 25min, 30min. STORE & REVIEWING ECG: 30 minutes oneimportant lead’s ECG waveform Alarm: 1800 groups Alarm events reviewing NIBP: 1000 groups NIBPmeasurement Arrhythmia: 128 groups data ( 8 seconds ECG waveform ) ENVIRONMENT Workingtemperature: 0~+40°C Transportation and storage temperature: 20~+55°C Relative humidity: Working ? 85%Transportation and storage ?93% Atmospheric pressure: Working 860~1060 hPa Transportation and storage500~1060 hPa STANDARD CONFIGURATION: ECG, HR, RESP, NIBP, SpO2, PR, TEMP, Battery Lead-acid OPTION: Litium battery, 2-TEMP, 2-IBP, Recorder, EtCO2 ( side stream, main stream ), AnestheticGas, Nellcor SpO2, ICG
Patient Monitor TR-900E Touchscreen
Slim Type Multi-Parameter Patient/Cardiac MonitorRead More
SKU:
Price:
Categories: Surgery
Product DescriptionTR-900E multi-parameter monitors new 15 inch (wall) product specifications (4.0) Product features ? Newultra-thin wall-mounted style, space-saving ease of placement and operation. ? High brightness, wideviewing angles, colorful TFT 15-inch 1024 * 678 resolution display, easy to observe. ? Touchscreenoperation, more efficient and convenient; and support the remote control operation. ? Interactive man-machine interface,multi-level menu , ample setup and displays the abundance intuitionistic contents. ?Comply with the YY0709 alarm system, eye-catching sub-column independent warning lights can prompt tothree sound and light alarm. ? Have a variety of styles of multi-lead ECG, Big font, RESP breathing,oxygenation, short trend display interface. ? With pacing analysis, can be used simultaneously withpacemakers, defibrillators. ? Freezing and releasing waveform function, analysis of ST-segment. With 192-hour trend graph, 1000 sets of NIBP list, arrhythmia analysis and other functions. ? With alarm, multi-levelpulse volume adjustable function; the parameter display colors can be adjusted based on user choice. ? Withuser information management function, to input patient information and identity management. ? Have aunique infrared remote control function to facilitate long-distance rounds operation. ? Dual-temperaturemeasurement, can simultaneously measure the temperature and temperature difference between the display
surface and the body cavity. ? External replaceable backup lithium battery, the battery can be used morethan Standard Masimo slot, ready to install the external Masimo SPO2 modules (plug & play) StandardRespironics ETCO2 slot, ready to install the Respironics ETCO2 modules (plug & play) Using Masimooximetry technology Tianrong patient monitor The first to introduce MASIMO external SPO2 module/Plug &Play
Anesthesia Machine Fabius® plus XL
Combines proven German engineering you can count on withhigh performance ventilation therapy.Read More
SKU:
Price:
Categories: Surgery
Product Description
BASE UNIT DIMENSIONS (W X H X D) Standard Trolley Version (Cart) with COSY with 2 VaporizersApprox. 35.8 x 56.7 x 30.3 in (91 x 144 x 77 cm) High Trolley Version (Cart) with COSY with 2 VaporizersApprox. 35.8 x 59 x 30.3 in (91 x 150 x 77 cm) Wall / Ceiling Version with COSY with 2-Vaporizers Approx.33.5 x 30.7 x 19.7 in (85 x 78 x 50 cm) WEIGHT AND LOAD Standard Trolley (with COSY) withoutsupplementary cylinders and vaporizers 297,6 lb (135 kg) High Trolley (with COSY) without reserve-gascylinders and vaporizers 308,7 lb (140 kg) Wall and Ceiling Mount (with COSY and without supplementarycylinders and vaporizers) 152.1 lb (69 kg) POWER AND BATTERY BACKUP Power Input 100 to 240 VAC,50/60 Hz, 70 VA Operation time with fully charged batteries 45 minutes minimum (up to 120 minutes) ANAESTHESIA GAS SUPPLY MODULE Range of fresh gas flow indicators 0.0 to 12.0 L/min O2 flush max.75 L/min at 87 psi (6 kPa x 100) Vapor mount Up to two Dräger (Auto Exclusion/Interlock) or Selectatec®Vapors optional additional Dräger (Auto Exclusion/Interlock) or Selectatec Vapor standby holder VENTILATOR OPERATING SPECIFICATIONS Ventilator E-vent® Electronically controlled, electricallydriven Operating modes Volume Controlled Ventilation Pressure Controlled Ventilation (Optional) PressureSupport (Optional) SIMV/PS (Optional) Manual Ventilation Spontaneous Breathing CONTROL INPUT RANGES Breathing Frequency (rate) 4 to 60 bpm (1/min) Positive End Expiratory Pressure (PEEP) 0 to 20cmH2O (hPa) Inspiration/expiration ratio (Ti:Te) 4:1 to 1:4 Pressure limiting (Pmax) 15 to 70 cmH2O (hPa)Tidal Volume (Vt) 20 to 1,400 mL in Volume Control 20 to 1,100 mL in SIMV/PS Inspiration pause (Tip:Ti) 0to 50 % SIMV Inspiratory time 0.3 - 4.0 sec Inspiratory pressure (Pinsp) PEEP + 5 to 65 cm H2O (hPa)Inspiratory Flow (InspFlow) 10 to 75 L/min in Volume and Pressure Control modes 10 to 85 L/min inPressure Support and SIMV/PS modes Pressure Support Level (PPS) PEEP +3 to 20 cmH2O (hPa) Min.frequency for apnoe-ventilation (Freq. Min.) 3 to 20 bpm and “OFF” Trigger level 2 to 15 L/min Technical DataIntegrated Safety Functions Sensitive Oxygen Ratio Controller (S-ORC) guarantees a minimum O2concentration of 23% in an O2 /N2O mixture. N2O cut-off if O2 fresh gas valve is closed or if O2 flow is lessthan 0.2 L/min. Audible and visual (flashing red LED) indication in case O2 pressure drops below 1.38 bar(20 psi) ± 0.27 bar (4 psi). In case of electricity and battery failure, manual ventilation, gas delivery and agentdelivery are possible. High Pressure Safety Relief Valve opens at 75 ± 5 cmH2O (hPa). Negative PressureSafety Relief Valve opens at -8 ± 2 cmH2O (hPa). VENTILATOR MONITORING Monitoring Continuousmonitoring of inspiratory O2 concentration (optional), breathing frequency, tidal volume expiration, expiratoryminute volume, peak airway pressure, PEEP, and selection of mean or plateau pressure. Expiratory Minute Volume Range 0 to 99 L/min Control Screen 10.4 in (26,4 cm) TFT color screen, day and night mode BREATHING SYSTEM
Optional breathing system heater yes Volume of entire compact breathing system, with absorber, excl. hoses, excl. bag 1.7 L Volume of CO2 absorber Standard: 1.5 L reusable canister, Option: 1.2 L prefilledDrägersorb CLIC absorber Mounting on swivel arm, left or right, height adjustable GAS SUPPLY AND CONNECTION Gas Supply Versions O2/ N2O/ Air, O2/, Air, O2/ N2O Cylinder Supply Versions (optional)O2, O2/ Air, O2/ N2O, 1 or 2 standing gas cylinders, pin-index hanger yokes for 2 cylinders OTHERCommunication Interface 1 RS-232 standard, additional RS-232 optional Protocols Vitalink and MEDIBUS Data available for Export All alarms, pressure, O2 and volume data, ventilation settings, flow curve andpressure curve Power outlets 2 integrated, medical grade power outlets with circuit breakers (option) Writing surfaces Pull-out tray (standard), Flip-up tray (optional) Additional accessories Anaesthetic gas scavengingsystem (AGSS), endotracheal suction unit, integrated auxiliary oxygen flowmeter, auxiliary common gasoutlet (CGO), low flow kit, power outlet strip Mounting options Mounting rails on side and rear panels, side/top mountings for patient monitor, patient gas measurement module, infusion pumps, infusion bags, storagebasket