![Page 1: Operating Instructions Compact 3020 HE - Welcome to Alde UK · PDF fileThe room thermostat is integrated into ... Being a combi-type boiler, the Alde 3020 Compact HE has an integrated,](https://reader033.vdocuments.us/reader033/viewer/2022051720/5a76f52c7f8b9ad22a8dd8aa/html5/thumbnails/1.jpg)
Operating Instructions
Compact 3020 HE
![Page 2: Operating Instructions Compact 3020 HE - Welcome to Alde UK · PDF fileThe room thermostat is integrated into ... Being a combi-type boiler, the Alde 3020 Compact HE has an integrated,](https://reader033.vdocuments.us/reader033/viewer/2022051720/5a76f52c7f8b9ad22a8dd8aa/html5/thumbnails/2.jpg)
CONTENTS
1. DOmESTiC HOT WaTEr........................3 1.1 Warning ...............................................3 1.2SpecifiedUse .......................................3 1.3SystemDesign .....................................32. DESCriPTiON OF FUNCTiONS .............4 2.1GasHeating .........................................4 2.2ElectricHeating ...................................4 2.3DomesticHotWater ............................43. DOmESTiC HOT WaTEr........................6 3.1DrainingFreshWater ..........................74. HEaT TraNSFEr FLUiD ........................8 4.1Filling....................................................9 4.2Draining ...............................................95. CENTraL HEaTiNG .............................10 5.1CirculationPump ...............................10 5.2BleedingAir .......................................11 5.3AirLock ..............................................12 5.4230VElectric ......................................12 5.5LiquefiedPetroleumGas ...................136. maiNTENaNCE ..................................15 6.1Winter ................................................157. CONTrOL PaNEL ................................17 7.1Startingthesystem ............................17 7.2StandbyScreen ..................................18 7.3 Main Menu ........................................19 7.4What’sActivatedMenu .....................24 7.5SettingsMenu....................................25 7.6What’sActivatedMenu .....................33 7.7ErrorLog ............................................33 7.8Reset ..................................................34 7.9Shuttingdownthesystem .................34 7.10InstalledAccessoriesMenu .............35 7.11Setup................................................36 7.12InterconnectingTheSystem............388. TrOUBLESHOOTiNG ..........................399. WarraNTY ........................................42
Revision29-01-16
![Page 3: Operating Instructions Compact 3020 HE - Welcome to Alde UK · PDF fileThe room thermostat is integrated into ... Being a combi-type boiler, the Alde 3020 Compact HE has an integrated,](https://reader033.vdocuments.us/reader033/viewer/2022051720/5a76f52c7f8b9ad22a8dd8aa/html5/thumbnails/3.jpg)
Alde Compact 3020 HE Operating Instructions
3
1.1 Warning!Aldecanacceptnoliabilitywhatsoeverfordamageorinjuryresultingfromfailuretoobservetheseinstructions.
1.2 Specified UseTheseinstructionsareapprovedfortheAlde3020CompactHEfittedincaravans,motorhomesorbuildingsinaccordancewithCE0402no.SC0653-13,andhavetheE5markforinstallationinvehiclesinaccordancewithECER122,no.00001andR10,no.04166,foruseincentralheatingandhotwatersystems.
Thesystemisnotintendedforusebypersons(includingchildren)withreducedphysical,sensoryormentalcapabilities,orlackofexperienceand/orknowledge,unlesstheyhavebeengiveninstructionoraresupervised.
Theterm“specifieduse”alsocoversobservanceoftheoperating,andinstallationandserviceinstructions(suppliedseparately).
TheAlde3020CompactHEmustbeinstalledorrepairedbyacompetentpersoninaccordancewithcurrentlocalregulations.
Intheunlikelyeventthatyoursystemdevelopsafault,switchoffthesystemandcontactAlde,oryourdealerorinstaller.The owner is always responsible for maintenance and arranging inspection.
1.3 System DesignTheboiler’sinternalheatexchangerconsistsofthreeconcentriccylinders;thecombustionchamber,thecentralheatingcylinderandthehotwatercylinder.
Thecombustionchamberismadefromaluminium,andisdividedintotwohalvesbyabaffleplate,withtheburnerheadlocatedinthetophalf,andthefluegasesventingthroughthebottomhalf.
Thecombustionassemblyisfixedtotheendoftheinternalheatexchanger.Itconsistsoftheburner,combustionfan,gasvalve,airintakeandexhaustducts,andgasline.
Twoelectricheatingelementsaresealedinsidethecentralheatingcylinder,onefor1kW,onefor2kW.
TheroomthermostatisintegratedintothetouchscreencontrolpanelandconnectedtotheboilerbyaRegisteredJack(RJ)cable.
1. DOmESTiC HOT WaTEr
![Page 4: Operating Instructions Compact 3020 HE - Welcome to Alde UK · PDF fileThe room thermostat is integrated into ... Being a combi-type boiler, the Alde 3020 Compact HE has an integrated,](https://reader033.vdocuments.us/reader033/viewer/2022051720/5a76f52c7f8b9ad22a8dd8aa/html5/thumbnails/4.jpg)
Alde Compact 3020 HE Operating Instructions
4
2. DESCriPTiON OF FUNCTiONS
2.1 Gas Heating
Whengasheatingissettoon,thecombustionfanstartstorevolve.Oncethecorrectspeedisachieved(inrpm),asignalissenttothePCBfortheburnertobelit.Thegasvalveopens,passinggas,andtheignitionmoduleonthePCBgeneratessparksattheelectrodeontheburnerhead.
Whentheburnerignites,aflamesupervisiondevicesignalstheignitionmoduletoceasesparking.Theburnerfiresuntiltheboilerorroomthermostatreachthesetpoint.
Shouldtheburnerflameoutunexpectedly,theFSDdetectsthisandattemptstoreignite(forabout10seconds),beforeshuttingdownandraisingafaultcode.
2.2 Electric Heating
Whenelectricheatingissetto1,2or3kW,relaysonthePCBtrip,feedingthe230Vsupplytotheelectricheatingelements.Thesearecontrolledbythesameprogrammeasthegasheating.
2.3 Domestic Hot Water
Thecombi-typeboilerautomaticallyproduceshotwater.Heatisemittedfromthecentralheatingcylinderintothehotwatercylinder.Ifthehotwatercylinderisempty,theairisheatedbutnodamagecanresult.
TiP!Listencarefullytotheignitionsequenceoftheboiler.Youshouldhearthewhirlofthecombustionfan,theclunkofthegasvalveandthetick-tickoftheignitionmodule.
TiP!Inagoodsummer,forexample,lowerthedesiredtemperatureonthecontrolpaneltoaround10°C.Thecentralheatingwillnotcirculate(unlessthetemperaturedropsto10°C),butyouwillstillhavehotwater.
![Page 5: Operating Instructions Compact 3020 HE - Welcome to Alde UK · PDF fileThe room thermostat is integrated into ... Being a combi-type boiler, the Alde 3020 Compact HE has an integrated,](https://reader033.vdocuments.us/reader033/viewer/2022051720/5a76f52c7f8b9ad22a8dd8aa/html5/thumbnails/5.jpg)
Alde Compact 3020 HE Operating Instructions
5
Theboilermustnotbeswitchedonifthereisnoheattransferfluid(HTF)inthesystem.
Alwaysdraindownthefreshwatersystemifthereisriskoffrost;inwinter,forexample.Youmaycontinuetousetheboilerwithnofreshwaterinthesystem,asrequired;nodamagecanresult.
AlwaysreplacetheHTFinaccordancewiththeantifreezeproduct’slifespan.Ifinanydoubt,replacetheHTFafter2years.
Onlysterilisethefreshwatersystemwithaproductsuitableforstainlesssteel.
Donotplacestowageintheboilercompartment.
Donotpositionawnings,tentsorotherenclosuresaroundtheflueterminal.
Donotobstructtheflue.Becarefulnottofloodthefluewhenwashingthevehicle.
Thegasheatingmustnotbeusedwhenrefuellingthevehicleattheservicestationorotherfuellingfacility.
!
!
!
!
!
!
!
!
imPOrTaNT!
![Page 6: Operating Instructions Compact 3020 HE - Welcome to Alde UK · PDF fileThe room thermostat is integrated into ... Being a combi-type boiler, the Alde 3020 Compact HE has an integrated,](https://reader033.vdocuments.us/reader033/viewer/2022051720/5a76f52c7f8b9ad22a8dd8aa/html5/thumbnails/6.jpg)
Alde Compact 3020 HE Operating Instructions
6
3. DOmESTiC HOT WaTEr
Beingacombi-typeboiler,theAlde3020CompactHEhasanintegrated,stainlesssteelhotwatercylinderthatholdsapproximately8.4litresoffreshwater.
Theboilercanproducearound12litresof40°Cwarmwaterper30mins(atacoldwatertemperatureof10°C).Ifonlytheelectricheatingisused,thiscapacityisslightlyreduced.
Onlyusepotablefreshwater.Greywater,desalinatedwater,orwaterotherwiseunfittodrinkisnotsuitableforuseasdomestichotwater.
Alwaysflushoutthehotwatercylinderbeforeuse,especiallywhenithasstoodemptyforsometime.
Targethotwatertemperatureisgreaterthan50°Cinnormaloperation,topreventthegrowthofLegionella.Over50°C,thehotwaterwillbeheatedtothemaximumachievabletemperatureatthetime.Thisallowsthehotwatertoachievedisinfectiontemperatures,andincreaseswarmwaterperformance.
Ifscaldinghotwatertemperaturesareaconcern–suchaswiththeyoung,elderlyorinfirm–thermostaticmixingvalves(TMVs)canbefitted,andmayberequiredbylocalregulations.
Avoidsteriliserproductscontainingsodiumhyperchlorite,forexample,asthesewillcauseseverecorrosiondamagetothehotwatercylinder,andisnotcoveredunderwarranty.Readtheproductlabelorcontacttheproductmanufacturerfordetails.
Whenthehotwatercylinderisincontinuoususe,itshouldbedrainedandrefilledonceamonth.Thisrecreatestheaircushioninthehotwatercylinderthatabsorbspressuresurges.
imPOrTaNT!Anysteriliserproductsshouldbesuitableforusewithstainlesssteel.
imPOrTaNT!Alwaysdraindownandcompletelyemptythehotwatercylinderwhenthereisriskoffrost,unlessthevehicleisexplicitlystatedtobeself-winterisingbythevehiclemanufacturer.
TiP!Ifcontinuouslyusingthehotwatercylinderinahardwaterarea,fitaninlinescaleinhibitortominimisetheeffectsoflimescale.
!
!
![Page 7: Operating Instructions Compact 3020 HE - Welcome to Alde UK · PDF fileThe room thermostat is integrated into ... Being a combi-type boiler, the Alde 3020 Compact HE has an integrated,](https://reader033.vdocuments.us/reader033/viewer/2022051720/5a76f52c7f8b9ad22a8dd8aa/html5/thumbnails/7.jpg)
Alde Compact 3020 HE Operating Instructions
7
3.1 Draining Fresh Water
1. Switchoffthewaterpump.2. Openallwatertaps,showers,etc.3. Openthesafety/drainvalvebyliftingthe
yellowtab(Fig1[M]),orbyturningtheblueknob(Fig1[K])90°.
4. Thesystemwilldraindirectlybelowthevehiclethroughtheclearplastichoseonthesafety/drainvalve.Checkthatallwaterhasemptiedout(7–10litres).Leavethevalveintheopenpositionuntilthenexttimethehotwatercylinderisused.
NB:Checkthattheredbreathervalve(Fig1[N])isallowingairtoenterthehotwatercylinder,whenitisbeingdrained,andthattheclearplastichoseisnotobstructed.
Closed Open m
Opening automatic safety valve/drain valve
Opening manual safety valve/drain valve
K
Figure 1.
N
![Page 8: Operating Instructions Compact 3020 HE - Welcome to Alde UK · PDF fileThe room thermostat is integrated into ... Being a combi-type boiler, the Alde 3020 Compact HE has an integrated,](https://reader033.vdocuments.us/reader033/viewer/2022051720/5a76f52c7f8b9ad22a8dd8aa/html5/thumbnails/8.jpg)
Alde Compact 3020 HE Operating Instructions
8
4. HEaT TraNSFEr FLUiD
Thecentralheatingsystemmustbefilledwithheattransferfluid(HTF);asolutionof50%ethyleneglycolantifreezeandwater.
Theantifreezemanufacturerwillhaveamaximumwaterhardnessrecommendation.Readtheproductlabelorcontacttheproductmanufacturerfordetails.
50:50ethyleneglycolantifreezeandwaterwillprotectagainstfrostdownto -35–-37°C.Arefractometerand/orhydrometercanbeusedtomeasurethestrengthoftheantifreezesolution.
Corrosionprotectionwillvarydependingonthelifespanoftheantifreeze.Readtheproductlabelorcontacttheproductmanufacturerfordetails.
Thecorrosioninhibitorsfoundinethyleneglycolantifreezemaynotbecross-compatible.WhentoppinguporreplacingtheHTF,ensurethenewantifreezeiscompatiblewiththecurrentantifreezeproduct.Readtheproductlabelorcontacttheproductmanufacturerfordetails.
FailuretofillwithsuitableHTFmayresultinseveredamagetoyourAldesystem,andisnotcoveredunderwarranty.
imPOrTaNT!TheboilermustnotbeswitchedonifthereisnoHTFinthesystem.
imPOrTaNT!AlwaysreplacetheHTFinaccordancewiththeantifreezeproduct’slifespan.Ifinanydoubt,replacetheHTFafter2years.
!
!
TiP!AlderecommendsantifreezemeetingVAGG12++orG13specification,anddeionisedwater(0ppm).
TiP!Asaroughguideline,blueandredantifreezeproductsareNOTcompatiblewitheachother,butVAGG12++andG13specantifreeze(magenta)iscompatiblewithboth.
![Page 9: Operating Instructions Compact 3020 HE - Welcome to Alde UK · PDF fileThe room thermostat is integrated into ... Being a combi-type boiler, the Alde 3020 Compact HE has an integrated,](https://reader033.vdocuments.us/reader033/viewer/2022051720/5a76f52c7f8b9ad22a8dd8aa/html5/thumbnails/9.jpg)
Alde Compact 3020 HE Operating Instructions
9
TiP!Theeasyway.ContactanAlde-certifiedserviceagenttodrainandrefillyoursystem.
4.1 Filling
ThecentralheatingsystemisfilledwithHTFthroughtheexpansiontank,eitherbyhand,orusingtheAldeservicepump.AnycontainersusedforhandlingorstoringtheHTFshouldbecheckedfirst,andmustbevisiblycleantoavoidintroducingcontaminantsorforeignobjectsintothesystem.
AlderecommendsusingtheAlde1900-811or839twin-motorservicepumptofillthesystem.
Tofillthesystembyhand,unscrewtheexpansiontankcap(Fig2[R]),andliftthecirculationpump(Fig2[S])outofthetank(ifapplicable).CarefullypourtheHTFintothetank,andrepeatuntilthefluidlevelisabout1cmabovetheMINmarkwhencold.
4.2 Draining
TheinstallershouldfitoneormoredrainsinthecentralheatingsystemtoallowdrainingoftheHTF.
Becausethepipesstepupanddown,someHTFwillbeleftinthesystemafterdraining.
r
S
Fluid level
Figure 2.
![Page 10: Operating Instructions Compact 3020 HE - Welcome to Alde UK · PDF fileThe room thermostat is integrated into ... Being a combi-type boiler, the Alde 3020 Compact HE has an integrated,](https://reader033.vdocuments.us/reader033/viewer/2022051720/5a76f52c7f8b9ad22a8dd8aa/html5/thumbnails/10.jpg)
Alde Compact 3020 HE Operating Instructions
10
5. CENTraL HEaTiNG
Theboilerissettoanupperlimittemperatureof85°C,i.e.thetemperatureoftheheattransferfluid(HTF)asitcirculatesaroundthepipes,radiators,convectors,etal.
Toensurethebestperformancefromhydronicheating,airmustbeabletocirculatefreelyaroundthebackofthefurniture(Fig3).Airvents,cutintothetopandbottomofthefurnituremustbeunobstructedbycarpets,cushions,orstowage,etc.
Thefulllengthofaconvectorshouldbeventilatedforbestperformance.
• 12Vexpansiontankcirculationpump.Thisclassicpumpisideallysuitedfortraditionalholiday-makers,orasalighterduty,off-gridoptionforthe230Vinlinecirculationpump.
• 12Vinlinecirculationpump.Thisheavyduty,variablespeedpumpisdesignedforfull-timemotorcamping.
• 230Vinlinecirculationpump.Thisheavydutypumpispowereddirectlybymainselectric,suitableforseasonalpitches.
TiP!Usegasandelectricheatingsimultaneouslyforthebestperformance.Theboilerwillonlyuseasmuchenergyasisneeded,andis93%efficientonaSEDBUKbasedtest.
5.1 Circulation Pump
ApumpisusedtocirculatetheHTFaroundthecentralheatingsystem.TherearethreemodelsofAldecirculationpump.
Figure 3.
![Page 11: Operating Instructions Compact 3020 HE - Welcome to Alde UK · PDF fileThe room thermostat is integrated into ... Being a combi-type boiler, the Alde 3020 Compact HE has an integrated,](https://reader033.vdocuments.us/reader033/viewer/2022051720/5a76f52c7f8b9ad22a8dd8aa/html5/thumbnails/11.jpg)
Alde Compact 3020 HE Operating Instructions
11
TiP!Contactthedealerorinstallerfordetailsonwherethebleedpointsareinyoursystem,andhowtoaccessthem.
5.2 Bleeding Air
TheHTFwillcontainsomeair.Thisisunavoidable.Airbubblescanalsobeintroducedwhenthesysteminfilled.
Inanewly-filledcentralheatingsystem,youwillneedtobleedairfromthebleedpointstoensurebestperformance.Thereisanautomaticairbleedvalveontheboiler.Thereisalsoanairventontheexpansiontank.
Theinstallershouldfitbleedpointselsewhereinthesystem,especiallywherethepipesstepupanddown,andonradiatorsandtowelrails.Airwillaccumulateatthesehighpointsandbecometrapped.
Tobleedthesystem,setthedesiredtemperatureto30°Candselectgasheatingonthecontrolpanel.
Setthe12Vinlinecirculationpumponthesideoftheboilertospeed5(Fig1[D]),byturningthebluespeeddialclockwise,onthefaceofthepumpmotor.NB:Speedisnotadjustableifusingthe12Vcirculationpumpfittedintheexpansiontank.
After10mins,setthepumpbacktoitsnormalrunningspeed(2foracaravan,3foramotorhome).
Moveontothenextbleedpointandrepeat,untilallbleedpointshavebeentendedto.
NowpowerofftheAlde3020CompactHEboilercompletely,makingsurethatthecirculationpumpisnotactive.
Followtheflowpipefromtheboiler,andbleedthesystemateachbleedpoint.
IfAldebleedpointshavebeenfitted,thesearemetalbleedscrewsmountedonblackEPDMrubberconnectors(Fig4).Haveaclothinhand.Toopen,turnthescrewanticlockwisebetweenthumbandforefinger.Airwillhissout.Whenfluidtricklesout,closethebleedscrewandmopupfluidwiththecloth.
Figure 4.
![Page 12: Operating Instructions Compact 3020 HE - Welcome to Alde UK · PDF fileThe room thermostat is integrated into ... Being a combi-type boiler, the Alde 3020 Compact HE has an integrated,](https://reader033.vdocuments.us/reader033/viewer/2022051720/5a76f52c7f8b9ad22a8dd8aa/html5/thumbnails/12.jpg)
Alde Compact 3020 HE Operating Instructions
12
5.3 air Lock
Ifenoughtrappedairaccumulatesatonepoint,anairlockcanresultandpreventthecirculationofhydronicheating.
Aramporsteepslopecanbeusedtoraiseoneendofthevehicle,causingthetrappedairtoshiftaroundthesystem.Repeatthefull
5.4 230V Electric
TheAlde3020CompactHEboilerhastwo230Velectricheatingelements,outputting1050Wand2100W,or3150Wcombined,anddrawing5A,9A,and14Arespectively(rounded).
230Vbreakers,fuses,fusedspursandisolatorswitchesshouldberatedfor16A.
Beforeusingelectricheating,checkthecurrentlimitontheelectricsupplyyouarehookingupto.
• 6Alimit,onlyuse1kWelectricheating.• 10Alimit,use1–2kWelectricheating.• 16Alimit,use1–3kWelectricheating.
NB:Iftheelectricsupplyhasunstablevoltage,theamperagewillalsofluctuate.
TiP!TheoptionalAlde3010-246loadmonitorallowsyoutosetalimitonthecurrentdrawnbythevehicleandtheelectricheatingtoautomaticallyaccommodateit.
bleedprocedure.Acaravancanbeslowlyandcarefullytiltedtoreproducethiseffect.
Toclearastubbornairlockinunder15minutes,anAlde-certifiedserviceagentcanusetheAlde1900-811or839twin-motorservicepump.
![Page 13: Operating Instructions Compact 3020 HE - Welcome to Alde UK · PDF fileThe room thermostat is integrated into ... Being a combi-type boiler, the Alde 3020 Compact HE has an integrated,](https://reader033.vdocuments.us/reader033/viewer/2022051720/5a76f52c7f8b9ad22a8dd8aa/html5/thumbnails/13.jpg)
Alde Compact 3020 HE Operating Instructions
13
5.5 Liquefied Petroleum Gas
LPG(liquefiedpetroleumgas)hastwomainvariants,propaneandbutanegas.ThegasheatinginyourAlde3020Compactboilercanusepropaneorbutanegasasfuel.ManyLPGfuelscontainamixtureofpropane,butaneandotheradditives.
BS5482Part1states,“For butane cylinders, satisfactory service might not be obtained at temperatures of less than 10 °C; the most suitable temperature range is from 13 to 30 °C. For temperatures less than 13 °C, the use of propane should be considered.”
Forthisreason,Alderecommendsusingpropanegasforallyearroundgasheating.
LPGcylinderscontainbothgasandliquidforms.Whenthecylinderisfilled,highpressuretransformsthegasintoliquid.Theliquidrevertstogaswhenthevalveonthecylinderisopened.
LPGisaflammablegas.Itcanbeafireandexplosionhazardifstoredorusedincorrectly.Storecylindersverticallyandsecurely,topreventthemfromtoppling.
DonotmountyourLPGcylinderhorizontallyoruseliquidphasegascylinders.Liquid–gasexplosionmayresult.Readtheproductlabelorcontactproductmanufacturerfordetails.
LPGisheavierthanair.Shouldagasleakoccur,floorventsinacaravanormotorhomeshouldallowthegastoescapefromthevehicle.Forthisreason,alwaysensurefloorventsareunobstructed.
imPOrTaNT!Theboilercompartmentcontainsthegasconnection,floorventsandthefluehoses.Donotplacestowageintheboilercompartment.
!
Intheeventofagasleak,orifyousmellgas:
• Extinguishallnakedflames• Openalldoorsandwindows• Closeallgasvalves,includingthevalveon
thecylinder.• Donotsmoke.• Donotoperateanyelectricalappliancesor
switches.• Arrangeforimmediateinspectionofthe
gassystembyacompetentpersoninaccordancewithcurrentlocalregulations.
LPGfromthecylinderisreducedinpressurebyaregulator,andissuppliedtotheboileratlowpressure(30mbar).Neveruseanunregulatedhighpressuresupply.
Whereoilanddirtinthegassupplyareaconcern,gasfiltersshouldbefittedtopreventblockageoftheboilergasvalve.
NB:Gasheatingmustnotbeusedwhilstdrivingyourvehicleunlessasafetyshut-offdeviceisfittedtothegassystem.Currentlocalregulationsmustbeadheredto.
![Page 14: Operating Instructions Compact 3020 HE - Welcome to Alde UK · PDF fileThe room thermostat is integrated into ... Being a combi-type boiler, the Alde 3020 Compact HE has an integrated,](https://reader033.vdocuments.us/reader033/viewer/2022051720/5a76f52c7f8b9ad22a8dd8aa/html5/thumbnails/14.jpg)
Alde Compact 3020 HE Operating Instructions
14
5.5.1 FlueTheburningofLPGproducesCO2(carbondioxide),anon-toxic,asphyxiantgas.
Exhaustfluegascancausepossibleburnsandpoisoning.Avoidinhalingexhaustfluegas.
imPOrTaNT!Donotpositionawnings,tentsorotherenclosuresaroundtheflueterminal.
imPOrTaNT!Donotobstructtheflue.Becarefulnottofloodthefluewhenwashingthevehicle.
imPOrTaNT!Airissuckedintothecombustionchamberviatheairintake.Thegasheatingmustnotbeusedwhenrefuellingthevehicleattheservicestationorotherfuellingfacility.
!
!
!
Airsupplyisessentialforcleancombustion.Theairintakeislocatedintheflueterminal.Forbestperformance,theflueterminalshouldbewellvented.Ifleavingthegasheatingunusedforaperiod,ensuretheflueterminaliscoveredtopreventpestanimalsnestingintheflue.
![Page 15: Operating Instructions Compact 3020 HE - Welcome to Alde UK · PDF fileThe room thermostat is integrated into ... Being a combi-type boiler, the Alde 3020 Compact HE has an integrated,](https://reader033.vdocuments.us/reader033/viewer/2022051720/5a76f52c7f8b9ad22a8dd8aa/html5/thumbnails/15.jpg)
Alde Compact 3020 HE Operating Instructions
15
6. maiNTENaNCE
Thereisnomanufacturer’sservicerequirementfortheAlde3020CompactHEboileritself.Currentlocalregulationsmustbeadheredto.Theinstallationoftheboilershouldbeinspectedannuallyforgassafety.
LPGhosesshouldberegularlycheckedforsignsofdamageandshouldbereplaced,atmaximum,after3yearsofuse.
Bleedairfromthesystemwhennewlyfilled,whenthevehiclehasbeenstandingunusedforaperiod,andbeforedepartingonholiday.
Thefluidlevelintheexpansiontankshouldbeabout1cmabovethemiNmarkwhencool.Theheattransferfluid(HTF)shouldbetoppedupifbelowthislevel,topreventabreakincirculation.OnlytopupwithcompatibleHTF.
NB:NeverleavethesystememptyofHTF.
FailuretomaintaintheconditionofHTFmayresultinfrostand/orcorrosiondamage,andisnotcoveredunderwarranty.
imPOrTaNT!AlwaysreplacetheHTFinaccordancewiththeantifreezeproduct’slifespan.Ifinanydoubt,replacetheHTFafter2years.
!
Whenthehotwatercylinderisincontinuoususe,itshouldbedrainedandrefilledonceamonth.Thisrecreatestheaircushioninthehotwatercylinderthatabsorbspressuresurges.
TheAldecontrolpanelrequiresnomaintenance,otherthancleaningofthescreenasneeded.Useamicrofibreclothtocleanthetouchscreen.
Panelradiatorsandtowelrailsshouldberegularlycleanedwithaclothandmulti-purposecleaner.
Whenshutdown,thesystemhasanormaldrawonthe12Vleisurebatteryofapproximately60mA.
6.1 Winter
Whencampinginthewinter,alwaysensuretheflueterminalremainsunobstructedbysnowandice.Extensionsforroofflueterminals,andcondensatespoutsforsideflueterminalsareavailablefromAlde.
Checkthestrengthoftheheattransferfluid(HTF)withahydrometerand/orrefractometer.Itshouldmeasure50%ethyleneglycolantifreeze,or-35– -37°C.
![Page 16: Operating Instructions Compact 3020 HE - Welcome to Alde UK · PDF fileThe room thermostat is integrated into ... Being a combi-type boiler, the Alde 3020 Compact HE has an integrated,](https://reader033.vdocuments.us/reader033/viewer/2022051720/5a76f52c7f8b9ad22a8dd8aa/html5/thumbnails/16.jpg)
Alde Compact 3020 HE Operating Instructions
16
Thecentralheatingcanstillbeusedwithnofreshwaterinthesystem.Theairinthehotwatercylinderisheatedbutnodamagecanresult.
Ifcampingintemperaturesbelow-10°C,considercarryingsparepartsintheeventofanemergency.Alderecommendsa12Vcirculationpumpfortheexpansiontank(withcabling),aPCB,and4–5litresofreadytouseantifreeze.Thesesparepartsshouldbekeptwellinsulatedandinthewarmestpartofthevehicle;forexample,inthewardrobe,neartotheexpansiontankpipes.
imPOrTaNT!Alwaysdraindownandcompletelyemptythehotwatercylinderwhenthereisriskoffrost,unlessthevehicleisexplicitlystatedtobeself-winterisingbythevehiclemanufacturer.
!
TiP!Airthevehicleoverwinterwithoutwearingoutthelighterdutypump.UseDelayedStart/CycleontheAldecontrolpaneltoautomaticallyheatthevehiclefor24hours,onceaweek.
Ifstoringthevehicleforwinter,ensuretheflueterminaliscoveredtopreventpestanimalsnestingintheflue.NB:ConsiderremovingtheAldecontrolpaneloverwinter,ifthevehicleistobekeptinstorageandissusceptibletodamp.
Ifusingthelighterduty12Vcirculationpumpintheexpansiontank,donotleavethecentralheatingonoverwinter,evenwithalowdesiredtemperatureset.
![Page 17: Operating Instructions Compact 3020 HE - Welcome to Alde UK · PDF fileThe room thermostat is integrated into ... Being a combi-type boiler, the Alde 3020 Compact HE has an integrated,](https://reader033.vdocuments.us/reader033/viewer/2022051720/5a76f52c7f8b9ad22a8dd8aa/html5/thumbnails/17.jpg)
Alde Compact 3020 HE Operating Instructions
17
imPOrTaNT!PleasereadtheAlde3020CompactHEoperatinginstructionsfullybeforeusingthesystem.
!
7. CONTrOL PaNEL
TheAlde3020CompactHEcontrolpanelhastwohard buttonsandanon-capacitive,colourtouchscreeninterface.Thesoft buttonsdisplayedonthescreenareoperatedbytouchingthescreenwithyourfinger.
7.1 Starting the system
3020High Efficiency
1. Boththecontrolpanelandboilerareoff.2. Tostartthesystem,pressthePowerbuttononthecontrolpanel.TheSplashScreenis
displayedandgreenLEDislit.Theboilerwillnowstartwiththepreviouslysavedsettings(factorysettingsbydefault).
Thesystemwillnowbedrawingvariable0.1–1.5Aofcurrentfromthe12Vsupply.
![Page 18: Operating Instructions Compact 3020 HE - Welcome to Alde UK · PDF fileThe room thermostat is integrated into ... Being a combi-type boiler, the Alde 3020 Compact HE has an integrated,](https://reader033.vdocuments.us/reader033/viewer/2022051720/5a76f52c7f8b9ad22a8dd8aa/html5/thumbnails/18.jpg)
Alde Compact 3020 HE Operating Instructions
18
7.2 Standby Screen
TheStandbyScreenisdisplayedaftertheSplashScreen.Thisscreencontainsusefulinformationaboutthestatusofyourheatingsystem.
NB:IfStandbyScreenissetto“Dark”inBacklightsettings,theStandbyScreenwillnotbedisplayed,thescreenwillbedarkunlesstouched.
22°C
6°C
Fri 18.30
D
C
a
J K
i
B
E F G HA. Clockisenabled.Dayoftheweekandtimeshown.
B. Outdoortemperature.[Optionaloutdoortemperaturesensorrequired.]
C. Roomtemperature.Measuredatthecontrolpanel.[Optionaldiscreteroomtemperaturesensorsavailable.]
D. Centralheatingcirculationpumpisactive.E. DelayedStart/Cycleisenabled.F. DayModeactive.G. Gascylinderstatus.Full/emptyandEisEx
modeshown.[Additionalaccessoriesrequired.]
H. NightModeactive.I. 230Vsupply.Ifnotdisplayed,theboileris
notreceiving230Vsupply.J. Powerbutton.Presstoswitchsystemon-
off.LitgreenLEDindicatessystemison.K. MENUbutton.PresstoaccessMainMenu
fromStandbyScreenorSettingsMenu.
![Page 19: Operating Instructions Compact 3020 HE - Welcome to Alde UK · PDF fileThe room thermostat is integrated into ... Being a combi-type boiler, the Alde 3020 Compact HE has an integrated,](https://reader033.vdocuments.us/reader033/viewer/2022051720/5a76f52c7f8b9ad22a8dd8aa/html5/thumbnails/19.jpg)
Alde Compact 3020 HE Operating Instructions
19
7.3 main menu
PressMENUbuttontoaccesstheMainMenufromtheStandbyScreenorSettingsMenu.ThescreenwillreverttotheStandbyScreenafter30secsifuntouched.
1. StandbyScreen.PressMENUbutton.2. Main Menu. a. What’sActivatedMenu.[Notdisplayedifnoactivatedfunctionsaredetected.] b. SettingsMenu
1 kW
+22°C
22°C
6°C
Fri 18.30
a
b
![Page 20: Operating Instructions Compact 3020 HE - Welcome to Alde UK · PDF fileThe room thermostat is integrated into ... Being a combi-type boiler, the Alde 3020 Compact HE has an integrated,](https://reader033.vdocuments.us/reader033/viewer/2022051720/5a76f52c7f8b9ad22a8dd8aa/html5/thumbnails/20.jpg)
Alde Compact 3020 HE Operating Instructions
20
1 kW
+22°C
7.3.1 Desired Room Temperature Thedesiredroomtemperaturecanbesetfrom5to30°C,in0.5increments.
7.3.2 Domestic Hot Water TheAldeboilerstores8.4litresofhotwaterasstandard.Ifthehotwatercylinderisempty,theairisheatedbutnodamagecanresult.
NB:IfDayorNightModeareactive,thetemperaturecannotbeadjusted,thePlusandMinusbuttonswillbegreyedout.
NB:IfDayorNightMode’sHotWaterIgnoreisactive,thehotwatercannotbeadjusted,thePlusandMinusbuttonswillbegreyedout.
1. Thecurrentdesiredroomtemperatureisdisplayed.2. AdjustbypressingPlusorMinusbutton.
TiP!TheWorldHealthOrganisationrecommendsaroomtemperatureof18–24°Cforhealthyliving.
TiP!Inagoodsummer,forexample,lowerthedesiredtemperatureonthecontrolpaneltoaround10°C.Thecentralheatingwillnotcirculate(unlessthetemperaturedropsto10°C),butyoucanstillcontrolhotwater.
![Page 21: Operating Instructions Compact 3020 HE - Welcome to Alde UK · PDF fileThe room thermostat is integrated into ... Being a combi-type boiler, the Alde 3020 Compact HE has an integrated,](https://reader033.vdocuments.us/reader033/viewer/2022051720/5a76f52c7f8b9ad22a8dd8aa/html5/thumbnails/21.jpg)
Alde Compact 3020 HE Operating Instructions
21
+22°C
1 kW
1 kW
+22°C
1 kW
+22°C
1. Hot Water Ignore.Volumebarempty.Noattemptismadetoheathotwaterspecifically.Thissavesenergywhenthefreshwaterisdraineddown.
2. Hot Water Normal.Volumebarhalf-full.Hotwaterisheatedtogreaterthan50°C.NB:IfCirculationPumpissettoContinuous,thisoptionwillnotbeavailable.
3. Hot Water Boost.Volumebarfull.Centralheatingcirculationisdisabledfor30mins.Hotwaterisheatedtogreaterthan65°C.After30minsthesystemrevertstoHotWaterNormal.
4. AdjustbypressingPlusorMinusbutton.
![Page 22: Operating Instructions Compact 3020 HE - Welcome to Alde UK · PDF fileThe room thermostat is integrated into ... Being a combi-type boiler, the Alde 3020 Compact HE has an integrated,](https://reader033.vdocuments.us/reader033/viewer/2022051720/5a76f52c7f8b9ad22a8dd8aa/html5/thumbnails/22.jpg)
Alde Compact 3020 HE Operating Instructions
22
7.3.3 Electric Heating Checkthat230VsupplyisdisplayedontheStandbyScreen.TheAldeboilerishard-wiredtousepowereconomicallyandtherearetimeswhenitmayusenopoweratall,evenifsetto3kW.
7.3.4 Gas Heating TheAldeboilerishard-wiredtousepowereconomically.Thegasburnerhastwostages,shiftingdynamicallybetweenloworfullflame.Therearetimeswhenitmayusenopoweratall,evenifgasheatingisselected.
Maxcurrentdrawfrom230Vsupplyis4.5Aon1kW,9Aon2kW,14Aon3kW.Iftheelectricitysupplyhasunstablevoltage,theamperagewillalsofluctuate.
Usebothgasandelectricheatingforbestperformance.
1. SelectOff,1,2or3kWelectricheating.Morepowerequalsbetterperformance,butmayberestrictedbythecurrent(amps)limitontheelectrichook-up.
2. AdjustbypressingPlusorMinusbutton.
1. PresstheFlamebuttontoselectgasheating.Greenison,blueisoff.
1 kW
+22°C
1 kW
+22°C
![Page 23: Operating Instructions Compact 3020 HE - Welcome to Alde UK · PDF fileThe room thermostat is integrated into ... Being a combi-type boiler, the Alde 3020 Compact HE has an integrated,](https://reader033.vdocuments.us/reader033/viewer/2022051720/5a76f52c7f8b9ad22a8dd8aa/html5/thumbnails/23.jpg)
Alde Compact 3020 HE Operating Instructions
23
7.3.5 Climate Control TheACbuttonisdisplayedwhenaTrumaAventaComfortair-conditioningunitisconnectedtotheAldecontrolpanel.Thisallowsfullyautomaticclimatecontrol,withtheheatingandair-conditioningworkinginunison.
Alderecommendsusingthe3010-238discreteroomtemperaturesensorforaccurateclimatecontrol.Itshouldbelocatedwheretheheatingandair-conhaveabalancedeffectontemperature.
1. Setthedesiredroomtemperatureasnormal.2. PresstheACbutton.Greenison,blueisoff.Theheating
andair-conditioningwillactivelymaintainthedesiredroomtemperature.
1 kW
+22°C
![Page 24: Operating Instructions Compact 3020 HE - Welcome to Alde UK · PDF fileThe room thermostat is integrated into ... Being a combi-type boiler, the Alde 3020 Compact HE has an integrated,](https://reader033.vdocuments.us/reader033/viewer/2022051720/5a76f52c7f8b9ad22a8dd8aa/html5/thumbnails/24.jpg)
Alde Compact 3020 HE Operating Instructions
24
7.4 What’s Activated Menu
PresstheAbuttontoaccesstheWhat’sActivatedMenu.Thisscreenshowsanyfunctionsthatareactivatedandallowsdirectaccesstothatfunctionbypressingitsbutton.NB:TheAbuttonisnotdisplayedifnofunctionsareactivated.
NightModeisenabled,butmayormaynotbeactive,dependingonthetimeandday.
DelayedStart/Cycleisenabled,butmayormaynotbeactive,dependingonthetimeandday.
AldeSmart-Controlordaisy-chained,thirdpartycontrolpanelisenabled.
Oneortwodiscreteroomtemperaturesensorsareconnected.
1 kW
+22°C Activated FunctionsA
Figure 7.4.1. Figure 7.4.2.
7.4.1 Guide to Activated Functions
CirculationPumpissettoContinuous.NB:Thiswillreducethehotwatersupply.
DayModeisenabled,butmayormaynotbeactive,dependingonthetimeandday.
ExternalSwitchisenabled,butmayormaynotbeinuse.
LoadMonitorisenabledandanamplimitisset.
![Page 25: Operating Instructions Compact 3020 HE - Welcome to Alde UK · PDF fileThe room thermostat is integrated into ... Being a combi-type boiler, the Alde 3020 Compact HE has an integrated,](https://reader033.vdocuments.us/reader033/viewer/2022051720/5a76f52c7f8b9ad22a8dd8aa/html5/thumbnails/25.jpg)
Alde Compact 3020 HE Operating Instructions
25
Boosterfanisenabled,butmayormaynotbeactive.
TrumaAventaComfortair-conditioningunitisconnected,butmayormaynotbeactive.
TrumaEisExdefrosterisenabled,butmayormaynotbeactive.
TrumaDuoControlorDuoControlCSregulatorisenabled.
EnginePre-Heatisenabled,butmayormaynotbeactive.
UnderfloorHeatingisenabled,butmayormaynotbeactive.
7.5 Settings Menu
PresstheToolButtontoaccesstheSettingsMenufromtheMainMenu.Lowerlevelfunctionscanbeaccessedbyfromthesescreensbypressingthebuttons.NB:Ifafunctionisnotavailableitsbuttonisgreyedout.
1 kW
+22°C
![Page 26: Operating Instructions Compact 3020 HE - Welcome to Alde UK · PDF fileThe room thermostat is integrated into ... Being a combi-type boiler, the Alde 3020 Compact HE has an integrated,](https://reader033.vdocuments.us/reader033/viewer/2022051720/5a76f52c7f8b9ad22a8dd8aa/html5/thumbnails/26.jpg)
Alde Compact 3020 HE Operating Instructions
26
ToreturntotheMainMenu,presstheMENUbutton.
Settings
16
15 19
18
Settings
6
5
1
2
3 4
17
78
Settings
10
9
11
12
13
14
20
7.5.1 Settings Menu Functions
![Page 27: Operating Instructions Compact 3020 HE - Welcome to Alde UK · PDF fileThe room thermostat is integrated into ... Being a combi-type boiler, the Alde 3020 Compact HE has an integrated,](https://reader033.vdocuments.us/reader033/viewer/2022051720/5a76f52c7f8b9ad22a8dd8aa/html5/thumbnails/27.jpg)
Alde Compact 3020 HE Operating Instructions
27
Delayed Start/Cycle (requires Clock to be set)Allowsyoutoprogrammetheboilertostartataspecifiedtimeandday,weekly.Itwillprovideheatingusingthelastsavedsettingsfor24hours,beforeautomaticallyshuttingdownagain.Thisisrecommendedforairingthevehicleoverwinterifstoredlocallyandhookedupto230Vpower.OnceDelayedStart/Cycleisenabled,thesystemshouldbeshutdownbypressingthePowerbutton.
ClockTheclockmustbesetforprogrammablefunctionstoactivateatthecorrecttime/day.If12Vpowerislost,theclockwillreset.
Night Mode (requires Clock to be set)Allowsyoutoprogrammetheboilertoautomaticallychangeandselectsettingsatnight.Setastartandstoptimeforthenight-timeperiod.Setadayoftheweek,or“All”forthesamedailyprogramme.Youcanalsodefine:
• Desiredroomtemperature• InvertStandbyScreen• Hotwaterignore• Temperaturesensor(ifdiscreteroomtemperaturesensorsareconnected)• ACQuietMode(ifTrumaAventaComfortair-conditioningunitisconnected)
Navigation ArrowsTherearefourscreensintheSettingsMenu.Theup/downarrowsallowyoutonavigatebetweenthem.
TiP!TheoptionalAlde3010-414batterybackupusestwoAAbatteriesandallowstheclockmemorytobestoredevenif12Vpowerislost.
![Page 28: Operating Instructions Compact 3020 HE - Welcome to Alde UK · PDF fileThe room thermostat is integrated into ... Being a combi-type boiler, the Alde 3020 Compact HE has an integrated,](https://reader033.vdocuments.us/reader033/viewer/2022051720/5a76f52c7f8b9ad22a8dd8aa/html5/thumbnails/28.jpg)
Alde Compact 3020 HE Operating Instructions
28
Day Mode (requires Clock to be set)Allowsyoutoprogrammetheboilertoautomaticallychangeandselectsettingsduringtheday.Setastartandstoptimefortheday-timeperiod.Setadayoftheweek,or“All”forthesamedailyprogramme.Youcanalsodefine:
• Desiredroomtemperature• Hotwaterignore
Temperature OffsetRecalibratetheroomtemperaturedisplayedbythecontrolpanelin0.5°Cincrements.Ifanoutdoortemperaturesensorisconnected,thiscanalsoberecalibrated.
BacklightThebrightnessoftheStandbyScreencanbeadjustedfrom1–3.ThedisplaymodeoftheStandbyScreencanalsobeset.
Dark.TheStandbyScreenisdeactivated,thecontrolpanelmayappeardormantexceptforthepowerLED.PressingthescreenwillactivatetheStandbyScreenfor30secs.Suitedforuseindark/night-timeconditions.Bright.TheStandbyScreenshowsdarkcharactersonalightbackground.Suitedforuseinbright/day-timeconditions.
ReturnReturntothepreviousmenu.
Button SoundBleepwhenabuttonispressed.
PrioritiseSelectwhethertoprioritisegasheatingorelectricheating,whenusingboth.Lessdemandwillbeplacedonthenon-prioritisedfuel.
TiP!Ifyou’rehookeduptoasitewithaflatrate230Vsupply,butstillwanttheextraperformancefromgasheating,prioritiseelectricheatingtosavemoneyongas.
![Page 29: Operating Instructions Compact 3020 HE - Welcome to Alde UK · PDF fileThe room thermostat is integrated into ... Being a combi-type boiler, the Alde 3020 Compact HE has an integrated,](https://reader033.vdocuments.us/reader033/viewer/2022051720/5a76f52c7f8b9ad22a8dd8aa/html5/thumbnails/29.jpg)
Alde Compact 3020 HE Operating Instructions
29
Circulation PumpSelectwhichcirculationpumptouseforthecentralheating,dependingonwhatpumpsareinstalled.
Pumpmodecanalsobeset.
Antimicrobial (requires Clock to be set)HotWaterBoostwillautomaticallyactivateat02:00everymorning.ThisfurtherreducestheriskofLegionellabacteria.
Pump Manual 12 V. Forthe12Vinlinecirculationpumpwithmanual5-speeddial.
Pump Remote 12 V. Fortheremote-controlled12Vinlinecirculationpump.Pumpspeedcanalsobeset.Speed2isrecommended.Speed4–5shouldonlybeusedpriortobleedingthesystemofair.
Optional Pump 12 V. Fortheoptional12Vcirculationpumpintheexpansiontank.
Pump 230 V. Forthe230Vinlinecirculationpump.
Auto. Automaticallyselectsthe230Vpumpwhena230Vsupplyisdetected,ortheoptional12Vpumpwhenonly12Vsupplyisavailable.
Invert.TheStandbyScreenshowslightcharactersonadarkbackground.Suitedforlowlightconditions.
Cont.Thepumpiscontinuouslyactive.Thiswillreducethehotwatersupply.Fortestingthecirculationpumpinthesummer,ifroomtemperatureexceeds30°C.
Thermo.Thepumpiscontrolledbytheroomthermostat.
![Page 30: Operating Instructions Compact 3020 HE - Welcome to Alde UK · PDF fileThe room thermostat is integrated into ... Being a combi-type boiler, the Alde 3020 Compact HE has an integrated,](https://reader033.vdocuments.us/reader033/viewer/2022051720/5a76f52c7f8b9ad22a8dd8aa/html5/thumbnails/30.jpg)
Alde Compact 3020 HE Operating Instructions
30
External SwitchAllowsyoutouseathirdparty,externalswitchtostartupandshutdowntheboiler.Whentheexternalswitchstartstheboiler,itwillprovideheatingusingthelastsavedsettings.OnceExternalSwitchisenabled,thesystemshouldbeshutdownbypressingthePowerbutton.Theexternalswitchthentakescontroloftheboiler.
LanguageSelectEnglish,FrenchorGermanlanguage.NB:TheServiceMenuisEnglishlanguageonly.
Booster SpeedIfaboosterfanconvectorisinstalled,thisallowsyoutoselectspeed1–2.Theboosterandcirculationpumpsharethesamecontrol.However,theboosterwillrunfor6minsafterthepumphasgoneinactive,andwillremainactiveifthepumpreactivatesduringthattime.
Ext.WhenacircuitismadeatX18ontheboiler,theboilerisstarted.Whenthecircuitisbroken,theboilershutsdown.Forusewithathirdpartyrockerortoggleswitch,orcompatibletelematicssystems.NB:TheAlde3010-219adaptorleadisavailableforconnectinganexternalswitch.
230V.When230Visdetected,theboilerisstarted.When230Vsupplyislost,theboilershutsdown.Noadditionalaccessoriesrequired.
Off.ExternalSwitchisdisabled.
TiP!Hiringoutavehicle?Yourcustomerscanoperatethecentralheating/hotwaterwithaconvenientwallswitch,whilstthecontrolpanelisfittedinalockedmaintenancecupboardwithadiscreteroomtemperaturesensor.On-off,nohassles.
![Page 31: Operating Instructions Compact 3020 HE - Welcome to Alde UK · PDF fileThe room thermostat is integrated into ... Being a combi-type boiler, the Alde 3020 Compact HE has an integrated,](https://reader033.vdocuments.us/reader033/viewer/2022051720/5a76f52c7f8b9ad22a8dd8aa/html5/thumbnails/31.jpg)
Alde Compact 3020 HE Operating Instructions
31
Temperature SensorIfanyAlde3010-238discreteroomtemperaturesensorsareconnected,thisallowsyoutoselect:
• Control panel.Temperatureismeasuredatthecontrolpanel.• Living room.Temperatureismeasuredatdiscreteroomtemperaturesensor1.• Bedroom.Temperatureismeasuredatdiscreteroomtemperaturesensor2.• Auto.Temperatureismeasuredatthecontrolpanel,butautomaticallyselectsa
discreteroomtemperaturesensorwhenconnected,prioritisingsensor1.Thisallowsthesensortobeselectedwithaconvenientwallswitch.
EisEx HeatingIfaTrumaEisExdefrosterisinstalled,thisallowsyoutoselect:
• Winter.EisExheatingforthegasregulatorison.• Summer.EisExheatingforthegasregulatorisoff.
IfaTrumaDuoControlorDuoControlCSgasregulatorisinstalled,gascylinderstatusisalsoshown.
Load MonitorIfanAlde3010-246loadmonitorisinstalled,thisallowsyoutosetanamplimitfrom5–17Aforthevehicle’s230Vpower.Ifthecurrentdrawnbythevehicleexceedstheamplimit,theboilerandTrumaAventaComfortair-conditioningunit(ifconnected)willautomaticallyreducepower.
Thishelpsavoidtrippingthecircuitbreakersontheelectrichookup.Theloadmonitorcanbedisabledbyselecting“Off”.NB:ACmustbeenabledonthecontrolpanelfortheTrumaAventaComfortair-conditioningunittorespondtotheloadmonitor.
Engine Pre-Heat (requires Clock to be set)IfanAlde2755-000enginepre-heatpumpisinstalled,allowsyoutousethecentralheatingasablockheater.Onceenabled,theenginepre-heatpumpwillcirculatefluidaroundtheengineradiator,viatheAldeengineheatexchanger,onthesettimeanddayforafixed60mincycle.NB:Ifthecentralheatingiscool,theenginewillnotbepre-heated.
![Page 32: Operating Instructions Compact 3020 HE - Welcome to Alde UK · PDF fileThe room thermostat is integrated into ... Being a combi-type boiler, the Alde 3020 Compact HE has an integrated,](https://reader033.vdocuments.us/reader033/viewer/2022051720/5a76f52c7f8b9ad22a8dd8aa/html5/thumbnails/32.jpg)
Alde Compact 3020 HE Operating Instructions
32
Dedicated Underfloor HeatingIfinstalled,thededicatedunderfloorheatingpumpandcirculationpumpsharethesamecontrol.Whenactive,thededicatedunderfloorheatingpumprunsin5minintervals.Thepumpmodecanalsobeset.
Delay.Thededicatedunderfloorheatingpumpwillrun,atintervals,for15,30,or120minsafterthecirculationpumphasgoneinactive.Itwillremainactiveifthecirculationpumpreactivatesduringthattime.
Cont.Thededicatedunderfloorheatingpumpwillrun,atintervals,continuously,irrespectiveofthecirculationpump.
Off.Thededicatedunderfloorheatingpumpisdisabled.
TiP!Alderecommendsnotexceedingafloorsurfacetemperatureof29°Ctoavoiddiscomfort.
![Page 33: Operating Instructions Compact 3020 HE - Welcome to Alde UK · PDF fileThe room thermostat is integrated into ... Being a combi-type boiler, the Alde 3020 Compact HE has an integrated,](https://reader033.vdocuments.us/reader033/viewer/2022051720/5a76f52c7f8b9ad22a8dd8aa/html5/thumbnails/33.jpg)
Alde Compact 3020 HE Operating Instructions
33
Settings Service
Water Temp: 55° CGlycol Temp: 80° C
Fan rotation: 0RPMCurrent: 0.0AOverheat: Deact
Service
Ext Switch: deactPCB Temp: 20° C
Boiler:Panel: s737R300B
7.6 Settings Menu
7.7 Error Log
PresstheToolButtontoaccesstheSettingsMenufromtheMainMenu.Lowerlevelfunctionscanbeaccessedbyfromthesescreensbypressingthebuttons.NB:Ifafunctionisnotavailableitsbuttonisgreyedout.
PresstheWarningbuttontoaccesstheErrorLogfromtheServiceMenu.Themostrecent20errormessagesaredisplayed.Toverifyanerrormessage,removethesystemfromthe12Vand230Vsupply.Wait10secsbeforerestoring12Vand230Vpowertothesystem.
Figure 7.6.1.
Figure 7.7.1.
Figure 7.6.2.
Figure 7.7.2.
Figure 7.6.3.
Error Log
2 Connection fail ext.1 Panel failure 2
3 Connection fail ext.4 Connection fail ext.5 Window open
Service
Water Temp: 55° CGlycol Temp: 80° C
Fan rotation: 0RPMCurrent: 0.0AOverheat: Deact
![Page 34: Operating Instructions Compact 3020 HE - Welcome to Alde UK · PDF fileThe room thermostat is integrated into ... Being a combi-type boiler, the Alde 3020 Compact HE has an integrated,](https://reader033.vdocuments.us/reader033/viewer/2022051720/5a76f52c7f8b9ad22a8dd8aa/html5/thumbnails/34.jpg)
Alde Compact 3020 HE Operating Instructions
34
7.8 Reset
PressResettorestorefactorydefaultsettings,andtheErrorLogwillbecleared.NB:TheMainMenuwillbesetto22°C,HotWaterNormal,1kWelectricheatingandgasheating.
imPOrTaNT!UsingResettorestorefactorydefaultsettingsdoesnotclearInstalledAccessories.
!
7.9 Shutting down the system
Tosaveenergy,thecontrolpanelonlyupdatestheboilerafterthelastadjustmentismade.Wait10secsbeforeshuttingdownthesystemtoensuretheboilerisupdated.
1. PressthePowerbuttonagain.Thescreengoesdark,thegreenLEDisunlit.Thesystemisoff.
![Page 35: Operating Instructions Compact 3020 HE - Welcome to Alde UK · PDF fileThe room thermostat is integrated into ... Being a combi-type boiler, the Alde 3020 Compact HE has an integrated,](https://reader033.vdocuments.us/reader033/viewer/2022051720/5a76f52c7f8b9ad22a8dd8aa/html5/thumbnails/35.jpg)
Alde Compact 3020 HE Operating Instructions
35
7.10 Installed Accessories Menu
AfterfittinganaccessorytotheAlde3020CompactHE,itmustbeinstalledinthecontrolpanelsoftwarebytickingtheboxforthataccessoryintheInstalledAccessoriesMenu,unlessotherwisenoted.PresstheInstalledAccessoriesbuttontoaccessthemenufromtheSettingsMenu.
Thefollowingoptionsareshownasstandard.Ticktheboxtoinstall:
• AldeSmartControl,orthirdpartycontrolpanel(connectedtoJP3onAldecontrolpanel)• Optional12Vcirculationpumpinexpansiontank(connectedatX4onboiler)• LoadMonitor(connectedtoX5onboiler)• 12Vinlinecirculationpumpwithmanual5-speeddial• Remotecontrolled12Vinlinecirculationpump• 230Vinlinecirculationpump
Settings
Inst Acc
Glykol pump tank
External panel
Load limiter
Inst Acc
Main Remot 12V
Main Manual 12V
Main 230V
Inst Acc
Duo Control
Booster
Load limiter
Inst Acc
Aux Hot Water Tank
Underfloor Heat Pump
Engine Pre-Heat Pump
Figure 7.10.1.
Figure 7.10.2. Figure 7.10.3. Figure 7.10.4. Figure 7.10.5.
![Page 36: Operating Instructions Compact 3020 HE - Welcome to Alde UK · PDF fileThe room thermostat is integrated into ... Being a combi-type boiler, the Alde 3020 Compact HE has an integrated,](https://reader033.vdocuments.us/reader033/viewer/2022051720/5a76f52c7f8b9ad22a8dd8aa/html5/thumbnails/36.jpg)
Alde Compact 3020 HE Operating Instructions
36
WithfollowingoptionsareshownwhentheAlde3020-023optionsdongleisconnected.Ticktheboxtoinstall:
• BoosterFan(connectedtoJP2onoptionsdongle)• DuoControlgasregulator(connectedtoJP7onoptionsdongle)• EisExdefroster(connectedtoJP6onoptionsdongle)• Underfloorheatingpump(connectedtoJP1onoptionsdongle)• Auxiliaryhotwatertank(connectedtoJP4onoptionsdongle)• Enginepre-heatpump(connectedtoJP3onoptionsdongle)
7.11 Setup
Howyousetupyoursystemwilldependonwhataccessoriesareinstalledandyouruserpreferences.Togetyoustarted,here’showtosetupsomeofthemorecommonfeatures.
7.11.1 Restore default factory settingsBeforeusingthesystemforthefirsttime,restoredefaultfactorysettings.Yourcontrolpanelmayhavebeentestedbythedealerorinstaller,andsomesettingsmayhavebeenchangedunintentionally.
1. PressToolbuttontoaccesstheSettingsMenu(bottomrightinMainMenu).2. Pressdownarrow,untilResetbuttonisdisplayed.3. PresstheResetbuttontoproceed.
7.11.2 Setup 12 V circulation pump in expansion tankTousethe12Vcirculationpumpintheexpansiontank,youmustsetitup.Thisisnotadefaultfactorysetting.NB:Thisonlyappliesifyouhavethe12Vcirculationpumpintheexpansiontank.
1. PressToolbuttontoaccesstheSettingsMenu(bottomrightinMainMenu).2. Pressdownarrow,untilInstalledAccessoriesbuttonisdisplayed.3. PresstheInstalledAccessoriesbuttontoaccessthemenu.Findandtick“OptionalPump”by
pressingthebox.Next,findanduntick“MainManual12V”.
![Page 37: Operating Instructions Compact 3020 HE - Welcome to Alde UK · PDF fileThe room thermostat is integrated into ... Being a combi-type boiler, the Alde 3020 Compact HE has an integrated,](https://reader033.vdocuments.us/reader033/viewer/2022051720/5a76f52c7f8b9ad22a8dd8aa/html5/thumbnails/37.jpg)
Alde Compact 3020 HE Operating Instructions
37
7.11.3 Setup Standby Screen for bedtimeThebacklightontheStandbyScreencanbedisturbingifthecontrolpanelisvisiblefromyourbed.Itcanbeinvertedforwhitetextonblackbackground.
1. PressToolbuttontoaccesstheSettingsMenu(bottomrightinMainMenu).2. Pressdownarrow,untilBacklightbuttonisdisplayed.3. PressBacklightbutton,selectInverttoproceed.
7.11.4 Setup Antimicrobial functionToactivelykillLegionella,setuptheAntimicrobialfunction.At2:00everynight,thehotwaterwillbeheatedtoover65°Cfor30mins.ThisfurtherreducestheriskofLegionella.
1. PressToolbuttontoaccesstheSettingsMenu(bottomrightinMainMenu).2. PressClockbutton,setthetimeandday.PressReturn.3. Pressdownarrow,untilAntimicrobialbuttonisdisplayed.4. PressAntimicrobialbuttontoproceed.
![Page 38: Operating Instructions Compact 3020 HE - Welcome to Alde UK · PDF fileThe room thermostat is integrated into ... Being a combi-type boiler, the Alde 3020 Compact HE has an integrated,](https://reader033.vdocuments.us/reader033/viewer/2022051720/5a76f52c7f8b9ad22a8dd8aa/html5/thumbnails/38.jpg)
Alde Compact 3020 HE Operating Instructions
38
7.12 Interconnecting The System
Thediagrambelowshowshowthesystemisinterconnected.Toavoidelectromagneticinterference,donotbundle12Vand230Vcablestogether.NB:AlwaysusegenuineAldeparts.
Control panel rear
V-30
2013
Rev
144
5
+Battery Back-up(3V DC)
Remote Sensor 1 Remote Sensor 2
Sofa
Bed
Heater
TIN BusExternal panel
Fuse 3.15A12 V DC 12 V pump
Control panel Tin bus
Option board/Mechanical panel
Externalstart
Windowcircuit breaker
Overloadprotection
Outdoorsensor
D
E
I
F
Circuit board on Compact 3020 HE boiler
Option board for Compact 3020 Mechanical panel3010 214
OUT 12V DCCONNECTED TO
HEATER MAINBOARD
FUSE
3.1
5 A
FLO
OR
PUM
P
FAN
BO
OST
ER
ENGI
NE
PUM
P
EXTR
A HO
T W
ATER
PU
MP
GAS
LEVE
LSE
NSO
R
EIS
EX
OPT
ION
HEAT
ERM
AIN
BOAR
D
12 V
DC
+
-
JP3
X1 X4
X18
JP1
X2
JP2 JP3 JP4 JP5JP6 JP7
X1
X6
X5 X7
X8A X8
X9
JP2F1JP2B1JP2A1JP1
*Truma Aventa Comfort AC is connected to one of the TIN Bus contacts.
![Page 39: Operating Instructions Compact 3020 HE - Welcome to Alde UK · PDF fileThe room thermostat is integrated into ... Being a combi-type boiler, the Alde 3020 Compact HE has an integrated,](https://reader033.vdocuments.us/reader033/viewer/2022051720/5a76f52c7f8b9ad22a8dd8aa/html5/thumbnails/39.jpg)
Alde Compact 3020 HE Operating Instructions
39
8. TrOUBLESHOOTiNG
AnyerrormessageswillbedisplayedontheStandbyScreen.Errormessagescanbeclearedbyremoving12Vsupplytotheboilerfor10secs.
The system is completely dead, the control panel is blank• Checkthe20mmT3.15Ampglassfuseintheboiler.Thisislocatedunderthelidoftheblack
plasticservicehatch,inagreenplasticfuseholder.• Checkthe12Vsupplytotheboiler,itshouldbeabove12V.• Checkthe12Vcableispluggedintotheboiler.CheckthecableispluggedintotheAlde
controlpanel.
The boiler will not ignite on gas, but no error message• Thesystemmaynotneedtousegasheatingifalsousingelectricheating.• Thefluidsintheboilermayalreadybeatoperatingtemperature.
The boiler will not heat on 230 V electric• Checkthecircuitbreakerandany230Vfuses.• Checkthatany230Visolatorswitchesareon(theywilloftenhaveanLEDindicatorand230
Vfuse).• Checkthe230Vsupplytothevehicle.• Thefluidsintheboilermayalreadybeatoperatingtemperature.
No hot water• CheckthatHotWaterIgnoreisnotactivatedontheAldecontrolpanel.• CheckthatContinuouspumpingisnotactivatedontheAldecontrolpanel.• CheckforotherconflictingsettingsontheAldecontrolpanel.• Checkthefreshwatersupplyandwaterpump.
![Page 40: Operating Instructions Compact 3020 HE - Welcome to Alde UK · PDF fileThe room thermostat is integrated into ... Being a combi-type boiler, the Alde 3020 Compact HE has an integrated,](https://reader033.vdocuments.us/reader033/viewer/2022051720/5a76f52c7f8b9ad22a8dd8aa/html5/thumbnails/40.jpg)
Alde Compact 3020 HE Operating Instructions
40
No central heating• Bleedthesystemofair.• Checkthefluidlevelintheexpansiontank.• Checkthatthecirculationpumpisresponding.• CheckthathotwaterboostisnotactivatedontheAldecontrolpanel.• Ifelectricheatingisnotbeingused,setitto“Off”ontheAldecontrolpanel.• Usegasandelectricheatingforbestperformance.• Checkthatventsinthefurniturearenotobstructed.• Checktheconditionoftheheattransferfluid.• Mostvehicleswillreachacomfortabletemperaturewithin40mins,innon-extreme
conditions.
Circulation pump active even though system is off• 12Vsupplytotheboilerdroppedto7Vmomentarily.Check12Vsupplyforstability.
“Panel failure 1” & “Panel failure 2”• Moistureistrappedinthecontrolpanel.• RemovetheAldecontrolpanelfromthevehicleandairinawarm,dryplaceovernight.
“Gas failure”• Outofgasorgasisnotigniting.• Checkthegascylinderisfull.Tryadifferentgascylinder,ensuringitispropanegas.• Checkthegasregulatorandanyisolationvalvesareopenandnotfrozen.
“Overheat red fail” or “Overheat blue fail”• Bleedthesystemofair.• Checkthefluidlevelintheexpansiontank.Itshouldbe1cmaboveMinmarkwhencool.• Checkthecorrectcirculationpumpisinstalled,selectedandresponding.• 12Vsupplytotheboilerdroppedto7Vmomentarily.Check12Vsupplyforstability.• Wait15minsforthefluidtocooldown.
“Overheat PCB”• Failsafeinboilerhastriggered.• Checkthefluidlevelintheexpansiontank.Itshouldbe1cmabovetheMinmarkwhencool.• Checktheboilercompartmentisventilated,andthattheventsareunobstructed.Donot
placestowageintheboilercompartment.
![Page 41: Operating Instructions Compact 3020 HE - Welcome to Alde UK · PDF fileThe room thermostat is integrated into ... Being a combi-type boiler, the Alde 3020 Compact HE has an integrated,](https://reader033.vdocuments.us/reader033/viewer/2022051720/5a76f52c7f8b9ad22a8dd8aa/html5/thumbnails/41.jpg)
Alde Compact 3020 HE Operating Instructions
41
“Fan failure”• Combustionfanspeedtoolow.Bearingmaybestiffafteraperiodofdisuse.• Automaticallyclearsafter5mins.Pleasetryagain.
“Connection failure”• LooseconnectionbetweenAldecontrolpanelandboiler.• Unplugcableatthecontrolpanelandboiler,thencarefullyplugbackin.• Checkthereisslackonthecableatthecontrolpanel,butnotexcessiveweightfromfree-
hanging/unmanagedcable.
“Window open”• Optionalwindowsensorhastriggered,gasheatingissuspended.Automaticallyclearsand
gasheatingresumeswhenwindowisclosed.
“3rd Party Panel C. Fail”• BreakincommsbetweenAldecontrolpanelandthirdpartycontrolpanel.• CheckthecablebetweentheAldecontrolpanelandthirdpartycontrolpanel.• Thirdpartycontrolpanelisinstalledinsoftwarebutnotfitted.• Untick“ThirdPartyPanel”inInstalledAccessoriesMenu.
“Low battery”• 12Vsupplytoboilerhasdroppedbelow10.5V,possiblycausingsystembrownout.• Automaticallyclearswhen12Vsupplyreaches11V.
“No match Heater/Panel”• ControlpanelisincompatiblewithboilerPCB.• Checkcontrolpanelpartnumber.Controlpanel3020-013isfor3020A-seriesboiler,3020-
113isfor3020HE-seriesboiler.
Ifproblemspersist,pleasecontactAlde,oryourdealerorinstaller.
Forourfrequentlyaskedquestions,ordownloadallinstructionmanuals,pleasevisitourwebsiteat:www.alde.co.uk
![Page 42: Operating Instructions Compact 3020 HE - Welcome to Alde UK · PDF fileThe room thermostat is integrated into ... Being a combi-type boiler, the Alde 3020 Compact HE has an integrated,](https://reader033.vdocuments.us/reader033/viewer/2022051720/5a76f52c7f8b9ad22a8dd8aa/html5/thumbnails/42.jpg)
Alde Compact 3020 HE Operating Instructions
42
9. WarraNTY
Aldeundertakestorectifyanymanufacturingdefectorearlycomponentfailurethroughnormalusethatoccurswithin2yearsoftheinstallationdate.
IfyourAldeboilerdevelopsafault,yourfirstactionshouldbetocontactyourdealerorinstaller,astheywillbefamiliarwithyourinstallationandvehicle,andhowtomakeaclaimunderwarranty.
AldeInternational(UK)LtdHuxleyCloseParkFarmSouthWellingboroughNorthamptonshireNN86AB
Tel.01933677765www.alde.co.uk
![Page 43: Operating Instructions Compact 3020 HE - Welcome to Alde UK · PDF fileThe room thermostat is integrated into ... Being a combi-type boiler, the Alde 3020 Compact HE has an integrated,](https://reader033.vdocuments.us/reader033/viewer/2022051720/5a76f52c7f8b9ad22a8dd8aa/html5/thumbnails/43.jpg)
Alde Compact 3020 HE Operating Instructions
43
![Page 44: Operating Instructions Compact 3020 HE - Welcome to Alde UK · PDF fileThe room thermostat is integrated into ... Being a combi-type boiler, the Alde 3020 Compact HE has an integrated,](https://reader033.vdocuments.us/reader033/viewer/2022051720/5a76f52c7f8b9ad22a8dd8aa/html5/thumbnails/44.jpg)
Alde International (UK) LtdHuxley Close, Park Farm South, Wellingborough,
Northants, NN8 6AB, Great Britain
Tel 01933 677765 • Fax 01933 674975 • www.alde.co.uk • [email protected]