BRITEGATE T-8 LED TUBES
2 ft 10W/ 0900 Lumens –
4 ft 18W/ 1600 Lumens –
4 ft 18W/ 1800 Lumens –
4 ft 28W/ 2600 Lumens –
All comes in 3kk(Warm White ), 4kk(Neutral
White) and 6kk(White) colour
![Page 3: Oneworks-BriteGate LED- Presentation (Jan 2014)](https://reader034.vdocuments.us/reader034/viewer/2022042907/587deea41a28abab7e8b479b/html5/thumbnails/3.jpg)
PRODUCT SPECIFICATION
Input Voltage 220-240v
Frequency 50Hz
Power Factor >0.92
Connector Base G13
Material Polycarbonate Clear/Frosted
Outline Dimension 1198mm x 28.3mm
IP 20
Operating temperature -20℃ - 40 ℃
Lifespan 50,000
Warranty 3 Years
CRI >70
Dimmer Yes
![Page 4: Oneworks-BriteGate LED- Presentation (Jan 2014)](https://reader034.vdocuments.us/reader034/viewer/2022042907/587deea41a28abab7e8b479b/html5/thumbnails/4.jpg)
FLUORESCENT REPLACEMENT
Philips 36W
Fluorescent
BriteGate T-8/T5
18W LED Lights
Lumens 2600 1800
Usable Lumens 1300 / (~2000 with
reflector)
1800
Power Consumption 42W 18W
Power factor 0.4-0.5 >0.92
Lifespan 8000 hours 50000 hours
Estimated Electricity
Usage / Year
(12 Hrs / Day)
~184kWh/ ~RM80 ~78kWh / ~RM 34
Why 36W Fluorescent need 42W of
electricity?
This is because ballast and starter also
requires electricity which increase the
total requirement of electricity usage
![Page 5: Oneworks-BriteGate LED- Presentation (Jan 2014)](https://reader034.vdocuments.us/reader034/viewer/2022042907/587deea41a28abab7e8b479b/html5/thumbnails/5.jpg)
TECHNOLOGICAL REPLACEMENT
Philips 36W
Fluorescent
BriteGate T-8
18W LED Lights
Material Mercury and Glass Full Polycarbonate
Clear/ Frosted
Fittings Requires reflector to
harness more lights
120 Degree Beam
Angle
Electrical Ballast and Starter None
Operating
Temperature
High ~20℃
![Page 6: Oneworks-BriteGate LED- Presentation (Jan 2014)](https://reader034.vdocuments.us/reader034/viewer/2022042907/587deea41a28abab7e8b479b/html5/thumbnails/6.jpg)
ROI CALCULATION
(COMPARING 18W LED VS 36W T8)
Assumptions :
i. Operating hours per day – 24 hrs
ii. Operating days per month – 30 days
iii. Operating days per year – 365 days
iv. Electricity tariff used in the calculation - Tariff B, 201kWh
onwards, RM0.509/kWh
v. Life span of T8 fluorescent lamp – 10 khrs
vi. Life span of T8 LED tube – 50 khrs
vii. 36W Fluorescent T8 tube cost – RM 8.00 per unit
viii. 18W LED tube cost – RM58.90 per unit
![Page 7: Oneworks-BriteGate LED- Presentation (Jan 2014)](https://reader034.vdocuments.us/reader034/viewer/2022042907/587deea41a28abab7e8b479b/html5/thumbnails/7.jpg)
18W LED T8 VS 36W FLUORESCENT T8 Specification 36W T8 BriteGate 18W
LED T8 Saving
s Lamp power 36W 18W 18W
Ballast lost 4W 0 4W
a. Total luminaire power
consumption
40W 18W 22W
b. Electricity tariff (Tariff B,
201kWh onwards)
RM0.509 RM0.509
-
c. Operating hours per day 24 hrs 24 hrs -
d. Number of days per year 365 days 365 days -
Annual electricity consumption,
kWh (a*c*d)
350 kWh 158 kWh 192 kWh
Annual electricity bill (RM) RM 178.15 RM 80.40 RM 97.75 *All above calculation are for single lamp & based on new tariff effective 1st January 2014
![Page 8: Oneworks-BriteGate LED- Presentation (Jan 2014)](https://reader034.vdocuments.us/reader034/viewer/2022042907/587deea41a28abab7e8b479b/html5/thumbnails/8.jpg)
ROI OF CONVERTING
FLUORESCENT T8 TO 18W LED T8 Number of lamps installed 1 lamp 1000 lamps 3000 lamps
Lamp power saving 22W 22 kW 66 kW
Annual electricity consumption
savings
192 kWh
192,000 kWh 576,000kWh
a. Annual electricity bill
savings
RM 97.75 RM 97,750.00 RM 293,250.00
b. Investment cost of 18W LED
T8
RM 58.90 RM 58,900.00 RM 176,700.00
ROI (b/a) – 24 hrs
operation
~ 0.6 year
ROI (b/a) – 12 hrs
operation
~ 1.2 year
![Page 9: Oneworks-BriteGate LED- Presentation (Jan 2014)](https://reader034.vdocuments.us/reader034/viewer/2022042907/587deea41a28abab7e8b479b/html5/thumbnails/9.jpg)
18W T8 SAVING TABLES
Number of lamps
installed
1 lamp 1000 lamps 3000 lamps
Lamp power saving 22W 22 kW 66 kW
Daily electricity saving 0.53 kWh 533 kWh 1,600 kWh
Daily $ saving RM 0.27 RM 271.50 RM 173.00
Monthly electricity saving 16 kWh 16,000 kWh 48,000 kWh
Monthly $ saving RM 8.14 RM 8145.00 RM 5,175.00
Annual electricity savings 192 kWh 192,000 kWh 576,000 kWh
Annual $ savings RM 97.75 RM 97,750.00 RM 293,250.00
DAILY
SAVINGS
MONTHLY
SAVINGS
ANNUAL
SAVINGS
![Page 10: Oneworks-BriteGate LED- Presentation (Jan 2014)](https://reader034.vdocuments.us/reader034/viewer/2022042907/587deea41a28abab7e8b479b/html5/thumbnails/10.jpg)
OTHER INTANGIBLE BENEFITS T8 Florescent
Tube
T8 LED Tube Delta
Power
Consumption
Typical 40W 18W (BriteGate
18W)
22W (BriteGate
18W)
Power Factor Typical < 0.45 Typical > 0.90 2X Better !
Rated Life Span 10K Hr. 50K Hr. 40K Hr.
Light
Deterioration
~10% per 8000 Hr. < 3% per 8000
Hr.
~ 3X Better !
![Page 11: Oneworks-BriteGate LED- Presentation (Jan 2014)](https://reader034.vdocuments.us/reader034/viewer/2022042907/587deea41a28abab7e8b479b/html5/thumbnails/11.jpg)
For Operation of ( 24Hr / Day X 365 Days / Year )
Electricity Bill Saving Per Tube = RM 97.75 per Year ( BriteGate “18W” ) , ROI < 1 Year !
( With continued saving over the entire useful life span , even beyond the 6th year…)
Year 1 Year 2 Year 3 Year 4 Year 5 Year 6
Onwards
Δ Saving Throughout Useful Life Span of T8 LED
ROI
Covered
Δ RM 97.75 x 4 Years ~ RM 390 !! Savings ( BriteGate: “ 18W” )
…Still Useful…
Saving Continue…
![Page 12: Oneworks-BriteGate LED- Presentation (Jan 2014)](https://reader034.vdocuments.us/reader034/viewer/2022042907/587deea41a28abab7e8b479b/html5/thumbnails/12.jpg)
WHY OUR T-8 LED
Latest Technology
4-in-1 Silicon Driver for power regulation, dimming capability, capacitor free, transformer free design
System-on-board design with no internal cabling
Full polycarbonate design without aluminum heat sink even at high wattage design
![Page 13: Oneworks-BriteGate LED- Presentation (Jan 2014)](https://reader034.vdocuments.us/reader034/viewer/2022042907/587deea41a28abab7e8b479b/html5/thumbnails/13.jpg)
HIGH BAY SERIES
No UV or IR light Radiation
Isolated driver compartment design to reduce the thermal effect to the light source
No Electrolytic capacitor
RoHS compliance. Mercury free design
Scalable light module & Adjustable arm to allow flexibility in installation method
Max 160W
>15k Lm
5700k CCT
CRI 70
IP 65
AC 240V
![Page 14: Oneworks-BriteGate LED- Presentation (Jan 2014)](https://reader034.vdocuments.us/reader034/viewer/2022042907/587deea41a28abab7e8b479b/html5/thumbnails/14.jpg)
HIGH CEILING SOLUTION
Down Light
Track Light
Project Light
Hi-Bay Light
![Page 15: Oneworks-BriteGate LED- Presentation (Jan 2014)](https://reader034.vdocuments.us/reader034/viewer/2022042907/587deea41a28abab7e8b479b/html5/thumbnails/15.jpg)
STREET LIGHT SOLUTION
LED and Power Transistor on PCB Sharing
Common Heat sink
Power Controller Module
![Page 16: Oneworks-BriteGate LED- Presentation (Jan 2014)](https://reader034.vdocuments.us/reader034/viewer/2022042907/587deea41a28abab7e8b479b/html5/thumbnails/16.jpg)
ONEWORKS LIGHTING SDN BHD (1059914 – A)
19-2, Jalan 1/116B,
Kuchai Entreprenuers’ Park
58200, KL
Tel: +603-79890250 Fax: +603-79890202
[email protected] / [email protected]
----- In Association with NationGate Technology Sdn Bhd -----
![Page 17: Oneworks-BriteGate LED- Presentation (Jan 2014)](https://reader034.vdocuments.us/reader034/viewer/2022042907/587deea41a28abab7e8b479b/html5/thumbnails/17.jpg)
Client List