oklahoma uniform building code commission irc building subcommittee presentation to commission...

36
Oklahoma Uniform Building Code Commission IRC Building Subcommittee Presentation to Commission November 17, 2010

Upload: primrose-wilkerson

Post on 17-Dec-2015

220 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: Oklahoma Uniform Building Code Commission IRC Building Subcommittee Presentation to Commission November 17, 2010

Oklahoma Uniform Building Code Commission

IRC Building SubcommitteePresentation to Commission

November 17, 2010

Page 2: Oklahoma Uniform Building Code Commission IRC Building Subcommittee Presentation to Commission November 17, 2010

Chapter 1

Scope and Administration

Page 3: Oklahoma Uniform Building Code Commission IRC Building Subcommittee Presentation to Commission November 17, 2010

Recommendation to Add:PreamblePursuant to 59 O.S. § 1000.23, the Uniform Building Code Commission has adopted the 2009 International

Residential Code (“2009 IRC”), as amended and revised by the Commission, as the minimum standards to be used by all entities for residential construction in jurisdictions throughout the State of Oklahoma. However, the Commission’s adoption of Chapter 1 “Scope and Administration” of the 2009 IRC is for continuity purposes only and the Commission’s adoption of Chapter 1 is limited to the Commission’s recognition of best practice in fully implementing the minimum standards for residential construction.

All other provisions of the Oklahoma adopted 2009 IRC other than Chapter 1, as amended and revised by the Commission, are hereby established and adopted as the statewide minimum standards for residential building construction in Oklahoma pursuant to 59 O.S. § 1000.23, which may only be amended or altered pursuant to Oklahoma law and the administrative rules of the Oklahoma Uniform Building Code Commission as set forth in Title 748, Chapter 15 of the Oklahoma Administrative Code.

The Commission’s limited adoption of Chapter 1 is made with the recognition that the legal authority granting state and local code administration and enforcement jurisdictions the power and discretion to administer and enforce codes arises from Oklahoma laws governing those jurisdictions. Furthermore, the Commission also recognizes that many state and local code administration and enforcement jurisdictions have already created, or have the lawful authority to create, departments, offices and administrative policies pursuant to various applicable laws and other adopted model codes with “Scope and Administration” provisions similar Chapter 1 of the 2009 IRC.

Accordingly, the provisions of Chapter 1 adopted herein are only intended to be in force and effect to the extent that the respective provisions do not conflict with State law or the lawful exercise of code administration and enforcement jurisdiction by entities empowered to do so pursuant to applicable law. Additionally, it is the intent of the Uniform Building Code Commission that the adoption of Chapter 1 shall create no positive or greater duties, responsibilities or obligations to code administration and enforcement jurisdictions other than those which already exist or hereafter arise as a matter of state or local law.

.

Vote: 100% For

Page 4: Oklahoma Uniform Building Code Commission IRC Building Subcommittee Presentation to Commission November 17, 2010

Chapter 2

Definitions

Page 5: Oklahoma Uniform Building Code Commission IRC Building Subcommittee Presentation to Commission November 17, 2010

Chap 2 Adopt: Vote: 100% For

Page 6: Oklahoma Uniform Building Code Commission IRC Building Subcommittee Presentation to Commission November 17, 2010

Chapter 3

Building Plans

Page 7: Oklahoma Uniform Building Code Commission IRC Building Subcommittee Presentation to Commission November 17, 2010

R302.1 Modify:

- Fire-resistant construction, exterior wallsRevise table R302.1 for minimum fire seperation

distance for walls and projections from • walls <5ft …… <3 ft. • Projections ≥ 2 ft to 5 ft ….. ≥ 2 ft to 3 ft

Vote: 100% For

Page 8: Oklahoma Uniform Building Code Commission IRC Building Subcommittee Presentation to Commission November 17, 2010

R310.1.1 Modify:

- Emergency escape and rescue openings, minimum opening area

Revise minimum clear opening from 5.7 sq ft to 5.0 sq ft

Ground level and elevated openings will now be equivalent.

Vote: 100% For

Page 9: Oklahoma Uniform Building Code Commission IRC Building Subcommittee Presentation to Commission November 17, 2010

R311.7.4.1 Amend:

-Stairway riser heightStairs to have risers within 3/8” variance at

rough-in. Top and bottom riser may vary by ¾” at final inspection.

Vote: 100% For

Page 10: Oklahoma Uniform Building Code Commission IRC Building Subcommittee Presentation to Commission November 17, 2010

R313.2 and R313.2.1Move to the Appendix:R313.2 One and two family dwelling automatic

fire systemsR313.2.1 Design and Installation

Vote: 100% For

Page 11: Oklahoma Uniform Building Code Commission IRC Building Subcommittee Presentation to Commission November 17, 2010

R315.1 Add Exception:

-Carbon Monoxide alarmsException #1Residences with attached garages and: 1) sealed

door between the residence and the garage, and 2) no fuel burning devices in the garage then carbon monoxide detection is not required within the residence.

Vote: 8 For 1 Against

Page 12: Oklahoma Uniform Building Code Commission IRC Building Subcommittee Presentation to Commission November 17, 2010

R323 Remove from thecode:- Storm sheltersRemove “In addition to other applicable

requirements in this code, storm shelters shall be constructed in accordance with ICC/NSSA 500”

Vote: 100% For

Page 13: Oklahoma Uniform Building Code Commission IRC Building Subcommittee Presentation to Commission November 17, 2010

Chapter 4

Foundations

Page 14: Oklahoma Uniform Building Code Commission IRC Building Subcommittee Presentation to Commission November 17, 2010

R402.2 Add:

Materials - ConcreteException #1Interior concrete slabs on grade and enclosed

garage slabs are not required to be air entrained.

Vote: 100% For

Page 15: Oklahoma Uniform Building Code Commission IRC Building Subcommittee Presentation to Commission November 17, 2010

R406.2 Add:

-Concrete and Masonry foundation waterproofing

Add the following to the list of approved materials

#8 Bentonite

Vote: 100% For

Page 16: Oklahoma Uniform Building Code Commission IRC Building Subcommittee Presentation to Commission November 17, 2010

Chapter 5

Floors

Page 17: Oklahoma Uniform Building Code Commission IRC Building Subcommittee Presentation to Commission November 17, 2010

R506.2.3 Add:

-Vapor Retarder“..or other industry accepted vapor retarder

products per manufacturers specifications”

Vote: 100% For

Page 18: Oklahoma Uniform Building Code Commission IRC Building Subcommittee Presentation to Commission November 17, 2010

Chapter 6

Wall Construction

Page 19: Oklahoma Uniform Building Code Commission IRC Building Subcommittee Presentation to Commission November 17, 2010

R602.4 Add:

-Interior load-bearing walls“Per the commentary this section is limited to

stud spacing and height per Table R602.3(5) and Table R602.3(1)

Vote: 100% For

Page 20: Oklahoma Uniform Building Code Commission IRC Building Subcommittee Presentation to Commission November 17, 2010

R602.10.6 Add:

-Braced wall panel connectionsException #4Wood sole plates of braced wall panels at

building interiors on monolithic slabs may be anchored using connector(s) with a shear capacity of 2300 lbs and a tensile capacity of 800 lbs over a maximum span of 6 feet.

Vote: 100% For

Page 21: Oklahoma Uniform Building Code Commission IRC Building Subcommittee Presentation to Commission November 17, 2010

Chapter 7

Wall Covering

Page 22: Oklahoma Uniform Building Code Commission IRC Building Subcommittee Presentation to Commission November 17, 2010

R703.8 Add:

- Flashing”“6 mil visqueen is an approved corrosion

resistant flashing when not exposed to UV light”

Vote: 100% For

Page 23: Oklahoma Uniform Building Code Commission IRC Building Subcommittee Presentation to Commission November 17, 2010

Chapter 8

Roof-Ceiling Construction

Page 24: Oklahoma Uniform Building Code Commission IRC Building Subcommittee Presentation to Commission November 17, 2010

R801.3 Remove from thecode:- Roof drainage“In areas where expansive or collapsible soils

are known to exist, all dwellings shall have a controlled method of water disposal from roofs that will collect and discharge roof drainage to the ground surface at least 5 feet from foundation walls or and approved drainage system”

Vote: 100% For

Page 25: Oklahoma Uniform Building Code Commission IRC Building Subcommittee Presentation to Commission November 17, 2010

R802.3 Add:

- Framing Details“Definition of a brace – 1) a triangular

configuration of framing members with a horizontal tie or rafter, 2) King post or similar”

Vote: 100% For

Page 26: Oklahoma Uniform Building Code Commission IRC Building Subcommittee Presentation to Commission November 17, 2010

R802.3 Add: Vote: 100% For

Page 27: Oklahoma Uniform Building Code Commission IRC Building Subcommittee Presentation to Commission November 17, 2010

R802.5.1 Add:

-Purlins“2x6 braces on 6 ft centers may be accepted in

place of the 2x4 braces on 4 ft centers”

Vote: 100% For

Page 28: Oklahoma Uniform Building Code Commission IRC Building Subcommittee Presentation to Commission November 17, 2010

Chapter 9

Roof Assemblies

No Changes

Page 29: Oklahoma Uniform Building Code Commission IRC Building Subcommittee Presentation to Commission November 17, 2010

Chapter 10

Chimneys and Fireplaces

No Changes

Page 30: Oklahoma Uniform Building Code Commission IRC Building Subcommittee Presentation to Commission November 17, 2010

Chapter 11

Energy Efficiency

Page 31: Oklahoma Uniform Building Code Commission IRC Building Subcommittee Presentation to Commission November 17, 2010

R1101.9 Move to Appendix:

- Certificate

Vote: 100% For

Page 32: Oklahoma Uniform Building Code Commission IRC Building Subcommittee Presentation to Commission November 17, 2010

R1102.4.3 Remove from thecode:- Air leakage, FireplacesRemove all mention of “gasketed doors” from

this section of the code.

Vote: 100% For

Page 33: Oklahoma Uniform Building Code Commission IRC Building Subcommittee Presentation to Commission November 17, 2010

R1103.1.1 Remove from thecode:- Programmable thermostat

Vote: 100% For

Page 34: Oklahoma Uniform Building Code Commission IRC Building Subcommittee Presentation to Commission November 17, 2010

R1103.2.2 Add:

-Duct Sealing“visual inspection may be used instead of the

roughin test and the post construction test”

Vote: 100% For

Page 35: Oklahoma Uniform Building Code Commission IRC Building Subcommittee Presentation to Commission November 17, 2010

R1103.8.3 Remove from the code:-Pool coversRemove first sentence of this section “Heated pools shall be equipped with a vapor

retardant pool cover on or at the water surface.”

Vote: 100% For

Page 36: Oklahoma Uniform Building Code Commission IRC Building Subcommittee Presentation to Commission November 17, 2010

R1104.1 Add:

-Lighting EquipmentException #1Can or recessed lights are exempt from this

section of the code

Vote: 100% For