oilgear pump controls

73
Innovative Fluid Power Oilgear Pump Controls PVWJ, PVG, and PVV PVWJ, PVG, and PVV

Upload: chadwick-branch

Post on 30-Dec-2015

139 views

Category:

Documents


3 download

DESCRIPTION

Oilgear Pump Controls. PVWJ, PVG, and PVV. Pump Controls. 3-way Style (PVWW/PVWJ) Typically used in circuits where fast response times are not necessary. 3- way Control Circuit. 3- way Pressure vs Volume. Pump Controls. 3-way Style (PVWW, PVWJ) - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Oilgear Pump Controls

Innovative Fluid Power

OilgearPump Controls

PVWJ, PVG, and PVVPVWJ, PVG, and PVV

Page 2: Oilgear Pump Controls

Innovative Fluid Power

Pump Controls

• 3-way Style (PVWW/PVWJ)– Typically used in circuits where fast response

times are not necessary.

Page 3: Oilgear Pump Controls

Innovative Fluid Power

3- way Control Circuit

Page 4: Oilgear Pump Controls

Innovative Fluid Power

3- way Pressure vs Volume

Page 5: Oilgear Pump Controls

Innovative Fluid Power

Pump Controls

• 3-way Style (PVWW, PVWJ)– Typically used in circuits where fast response

times are not necessary.

• 4-way Style (PVG, PVV)– Typically used in circuits where fast response is

critical.

Page 6: Oilgear Pump Controls

Innovative Fluid Power

4- way Control Circuit

OP-2

Page 7: Oilgear Pump Controls

Innovative Fluid Power

4- way Pressure vs Volume

Page 8: Oilgear Pump Controls

Innovative Fluid Power

PVWJ Controls

Page 9: Oilgear Pump Controls

Innovative Fluid Power

3-way Style ControlsPVWJ

• P-1NN, P-LNN Single Pressure Compensator

• P-1NN/F Load Sense Compensator (PVWJ)

• P-CNN, P-KNN Soft start Compensator

• HP Horsepower Limiter

• G Horsepower limiter with load sense

Page 10: Oilgear Pump Controls

Innovative Fluid Power

PVWJ P-1NN Control

RP Port

Access for lifting eye

Pressure adj. Screw

Page 11: Oilgear Pump Controls

Innovative Fluid Power

3-Way - P-1NN or P-LNN

CN ControlCN Control

P-1NN or P-LNN

Page 12: Oilgear Pump Controls

Innovative Fluid Power

Full Stroke

Spool Drain

Pressure Compensator Adjustment

Optional Minimum Volume Stop

Plug 361

Maximum Volume Stop

Page 13: Oilgear Pump Controls

Innovative Fluid Power

Zero “Slip Stroke”

Optional Minimum Volume Stop

Pressure Compensator Adjustment

Spool Drain

Maximum Volume Stop

Plug 361

Page 14: Oilgear Pump Controls

Innovative Fluid Power

P-LNN

• We offer a low pressure version of the PVWJ pump. The designator for this control is P-LNN. This control will allow the pump to go to a minimum compensator setting of approximately 150 psi. The pumps maximum pressure limit is 1500 psi.

Page 15: Oilgear Pump Controls

Innovative Fluid Power

P-1NN and P-LNNControl Stability Orifice

Compensator spool

Page 16: Oilgear Pump Controls

Innovative Fluid Power

P-1NN or P-LNN Port Locations

Compensator Inlet

Compensator Spool Drain

Compensator Spring Drain

Control Spring Drain

Page 17: Oilgear Pump Controls

Innovative Fluid Power

Changes in the Control

• The PVWJ-P-1 pressure compensating control is functionally the same as the previous PVWH-CN control with improvements to the control to; increase stability, reduce control generated noise, and ease of field adjustment. Some of these changes are:– New dampened compensator spool

Page 18: Oilgear Pump Controls

Innovative Fluid Power

PVWJ Control Changes

• New Compensator Spool

PVWJ

PVWH

Page 19: Oilgear Pump Controls

Innovative Fluid Power

Changes in the Control

• The PVWJ-P-1 pressure compensating control is functionally the same as the previous PVWH-CN control with improvements to the control to; increase stability, reduce control generated noise, and ease of field adjustment. Some of these changes are: – New dampened compensator spool

– Dual compensator springs

Page 20: Oilgear Pump Controls

Innovative Fluid Power

PVWJ Control Changes

• Dual Compensator Springs

Page 21: Oilgear Pump Controls

Innovative Fluid Power

P-1NN or P-LNN

New Dampened Compensator Spool

Dual Compensator SpringsNew Spring Seat

Page 22: Oilgear Pump Controls

Innovative Fluid Power

Changes in the Control

• The PVWJ-P-1 pressure compensating control is functionally the same as the previous PVWH-CN control with improvements to the control to; increase stability, reduce control generated noise, and ease of field adjustment. Some of these changes are: – New dampened compensator spool

– Dual compensator springs

– New compensator adjustment assembly

Page 23: Oilgear Pump Controls

Innovative Fluid Power

PVWJ Control Changes

• New Adjustment Assembly

• Shims are now used to increase the maximum pressure, instead of reducing pressure as in the PVWH series

The screw that holds the adjustment shims, screws in to the pressure adjusting screw.

Spring Seat and O-ring Seal

Page 24: Oilgear Pump Controls

Innovative Fluid Power

PVWH vs. PVWJ

PVWHPVWJ

Page 25: Oilgear Pump Controls

Innovative Fluid Power

Changes in the Control

• The PVWJ-P-1 pressure compensating control is functionally the same as the previous PVWH-CN control with improvements to the control to; increase stability, reduce control generated noise, and ease of field adjustment. Some of these changes are: – New dampened compensator spool

– Dual compensator springs

– New compensator adjustment assembly

– New control housing

– NO GASKETS!!

Page 26: Oilgear Pump Controls

Innovative Fluid Power

PVWJ

• As you can see in the photo on the right, the pump housing has been machined to accept an o-ring to seal the case.

• The compensator inlet o-ring has been relocated to pump housing

Page 27: Oilgear Pump Controls

Innovative Fluid Power

PVWJ Control Orifices

• Standard Control Stability Orifice Sizes– PVWJ-011/014/022 .040” (1,016

mm)– PVWJ-025/034/046 .040” (1,016

mm)– PVWJ-064/076/098/130 .050” (1,27 mm)

• All standard orifices are drilled 10-24 X ¼” hollow hex set screws.

Page 28: Oilgear Pump Controls

Innovative Fluid Power

Control Piston Orifice

Page 29: Oilgear Pump Controls

Innovative Fluid Power

P-1NN/F, and P-LNN/F

Page 30: Oilgear Pump Controls

Innovative Fluid Power

P-1NN/F, and P-LNN/F

RP1 Port

Max. Volume Stop

Load Sense Port

Page 31: Oilgear Pump Controls

Innovative Fluid Power

P-1NN/FNN, or P-LNN/FNN

Page 32: Oilgear Pump Controls

Innovative Fluid Power

P-1NN/FNN

Compensator InletCompensator Spring Drain

What’s Missing?

Page 33: Oilgear Pump Controls

Innovative Fluid Power

P-1NN/FNN

Compensator InletCompensator Spring Drain

What’s Missing?Besides the control piston!

Page 34: Oilgear Pump Controls

Innovative Fluid Power

P-1NN/FNN

Compensator InletCompensator Spring Drain

What’s Missing?

The spool drain!

Page 35: Oilgear Pump Controls

Innovative Fluid Power

P-1NN/F and P-LNN/F

• In all P-1NN/F, P-LNN/F, P-C**, and P-K** controls the spool drains are not drilled.

P-1NN

P-1NN/F

Page 36: Oilgear Pump Controls

Innovative Fluid Power

P-1NN/FNN vs P-1NN/FSN

• The pictures to the right show an “A” frame PVWJ without a maximum volume stop, and a P-1NN/FSN control with a maximum stop.

• Unlike the PVWH, the PVWJ incorporates a transition block which allows the LS module to be rotated 90° to facilitate a maximum stop. This eliminates the need to relocate the module to the top of the control housing.

Adjustable LS Option

Fixed LS Option

Page 37: Oilgear Pump Controls

Innovative Fluid Power

P-1NN/F

• Options for the PVWJ load sense modules:– F = Fixed P 170 psi

– J = Adjustable P 100-220 psi

– K = Adjustable P 225-350 psi

Fixed module is shown

Page 38: Oilgear Pump Controls

Innovative Fluid PowerInnovative Fluid Power

P-1NN/FNN Diagram

Note:

The restrictiondevice and loadsense line are

customersupplied.

RP Port

Port RP

Page 39: Oilgear Pump Controls

Innovative Fluid Power

System Header

Remote Relief Valve

.030” orifice

PVWJ Pumps w/P-1NN/F-ADJ* Control

Remote Compensating PVWJ Pumps using Adjustable Load Sense Controls

Page 40: Oilgear Pump Controls

Innovative Fluid Power

Load Sense Control

• Primarily used on mobile equipment to help minimize wasted horsepower.– Allows the pump maintain a constant flow

regardless of pressure, within ± 5%.– Helps minimize heat generated in the system.

• By maintaining a constant P across a customer supplied restriction, i.e. flow control, proportional valve, etc.

Page 41: Oilgear Pump Controls

Innovative Fluid Power

2 Speed Motor Circuit - Fixed Volume

HP Required @ 34 GPM = 35.00

HP Required @ 15 GPM = 70.00

Why is the horsepower double @ 15 GPM

15 gpm

34 gpm

1500 psi

34 gpm

3000 psi

Page 42: Oilgear Pump Controls

Innovative Fluid Power

34 GPM

2 Speed Motor Circuit - Pressure Compensated

34 gpm

15 gpm

34 gpm

1500 psi

3000 psi

HP Required @ 34 GPM = 35.00 hp

HP Required @ 15 GPM = 31.00 hp

HP Saving Over Fixed Pump @ 15 GPM = 39.00 hp

3200 psi

Page 43: Oilgear Pump Controls

Innovative Fluid Power

1500 psi Working Pressure

1670 PSI

HP

2 Speed Motor Circuit - Load Sense

HP Required @ 34 GPM = 35.00 hpHP Required @ 15 GPM = 18.00 hp

HP Savings L.S. vs. Fixed = 52.00 hp HP Savings L.S. vs. P Comp. = 14.00 hp

.020 Bleed Orifice

3200 psi

3000 psi

P 170

15 gpm

34 gpm

1500 psi

Page 44: Oilgear Pump Controls

Innovative Fluid Power

Why Use a Load Sense over a Pressure Compensated Control?

• Cost

• Stability

• Ability to remote compensate more than a single pump.

Page 45: Oilgear Pump Controls

Innovative Fluid Power

P-C** or P-K** Soft Start

Page 46: Oilgear Pump Controls

Innovative Fluid Power

P-C** or P-K** Soft Start

Page 47: Oilgear Pump Controls

Innovative Fluid Power

P-K**

Page 48: Oilgear Pump Controls

Innovative Fluid Power

P-K**

Why is this control a P-K**?

Page 49: Oilgear Pump Controls

Innovative Fluid Power

P-K**

Why is this control a P-K**?

N.C. Two-Way Valve

Page 50: Oilgear Pump Controls

Innovative Fluid Power

PVG/PVV Controls

Page 51: Oilgear Pump Controls

Innovative Fluid Power

4-way Style Controls

• Pumps that use a 4-way style control

Page 52: Oilgear Pump Controls

Innovative Fluid Power

4-way Style Controls

• Pumps that use a 4-way style control– PVG

Page 53: Oilgear Pump Controls

Innovative Fluid Power

4-way Style Controls

• Pumps that use a 4-way style control– PVG– PVV

Page 54: Oilgear Pump Controls

Innovative Fluid Power

4-way Style Controls

• P-1NN Single Pressure Compensator

• P-2NN Dual Pressure Compensator

• P-A** N.O Proportional Pressure Compensator

• P-B** N.C. Proportional pressure Compensator

• P-C** Single Pressure w/ No Load Starting

Page 55: Oilgear Pump Controls

Innovative Fluid Power

4-way Style Controls

• P-1NN/F Single Pressure w/ Load Sense

• P-1NN/H Single Pressure w/ Horsepower Limiting

• P-1NN/G Single Pressure w/ HP Limiting & Load Sense

• P-1NN/K Single Pressure w/ Load Sense Plus

Page 56: Oilgear Pump Controls

Innovative Fluid Power

P-1NN 4-way Pressure Control

• Features included in these style of controls

– Easily Remotely Compensated– Critical Orifice Ports tapped for orifice plugs.

Page 57: Oilgear Pump Controls

Innovative Fluid Power

P-1NN Compensator

OP2

OP14

OP6

OP3 OP4GPARemote Port 1

Page 58: Oilgear Pump Controls

Innovative Fluid Power

P-1NN 4-way Pressure Control

• Typically this control is used where very fast response is required.– Response times of 45-55 milliseconds (PVG)

• Set works in sawmills

Page 59: Oilgear Pump Controls

Innovative Fluid Power

Full Stroke

Page 60: Oilgear Pump Controls

Innovative Fluid Power

Compensated “Slip Stroke”

Page 61: Oilgear Pump Controls

Innovative Fluid Power

Orifice Locations

OP-10

OP-4

OP-3

OP-2

OP-14

OP-1

OP-6

OP-5

Page 62: Oilgear Pump Controls

Innovative Fluid Power

OP 1

OP 14

Page 63: Oilgear Pump Controls

Innovative Fluid Power

Remote Compensating a Single PVG

Page 64: Oilgear Pump Controls

Innovative Fluid Power

P-1NN/F Load Sense Control

OP2

OP14

Customer Supplied

Page 65: Oilgear Pump Controls

Innovative Fluid Power

Remote Compensating Multiple 4 way Style Pump Controls

To System

Page 66: Oilgear Pump Controls

Innovative Fluid Power

P-1NN/F Load Sense Control

Page 67: Oilgear Pump Controls

Innovative Fluid Power

P-1NN/F Load Sense Plus

OP3 OP4OP2

RP1

OP1

A

B

GPA

OP6

OP8

OP15

LS

Customer Supplied

Page 68: Oilgear Pump Controls

Innovative Fluid Power

Delta P Adjustment

Stand-by Adjustment

Compensator Adjustment

Page 69: Oilgear Pump Controls

Innovative Fluid Power

P-2NN Dual Pressure Control

Page 70: Oilgear Pump Controls

Innovative Fluid Power

P-2NN Compensator - Full Stroke

Low Pressure Adjustment

High Pressure Adjustment

Solenoid Selector

Page 71: Oilgear Pump Controls

Innovative Fluid Power

P-C NN Soft Start Control

Page 72: Oilgear Pump Controls

Innovative Fluid Power

Unloading Solenoid

Valve

Page 73: Oilgear Pump Controls

Innovative Fluid Power

Thank you for buying Oilgear Products