oil solutions · oil solutions 100/200/300 series ... 3000psi 02qx ff 3 ≥200 >1000 >3000...

22
Oil Solutions 100/200/300 Series High Pressure Filters Filtration Global Filtration Technology www.oilsolutions.com.au

Upload: vuongdiep

Post on 02-Jul-2018

215 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Oil Solutions · Oil Solutions 100/200/300 Series ... 3000psi 02QX FF 3 ≥200 >1000 >3000 >5000 INF INF 5 High 99.5 99.9 99.97 99.98 ... Hirschmann Connector Part Voltages

Oil Solutions100/200/300 SeriesHigh Pressure Filters

FiltrationGlobal Filtration Technology

www.oilsolutions.com.au

Page 2: Oil Solutions · Oil Solutions 100/200/300 Series ... 3000psi 02QX FF 3 ≥200 >1000 >3000 >5000 INF INF 5 High 99.5 99.9 99.97 99.98 ... Hirschmann Connector Part Voltages

High Pressure Filters100/200/300 Series

Parker Hannifin CorporationHydraulic Filter DivisionMetamora, OH

Features/Applications forHigh Pressure HydraulicFilters � 100 Series

■ Pressures to 6,000 PSI

■ Flows to 25 GPM

■ BetaMaze Elements -3 to 20 Micron Absolute

■ Disposable orRecleanable Elements

108

SpecificationsHigh Pressure Hydraulic Filters - 100 Series

Max. Flow Rating: 25 GPM

Pressure Rating:Operating Pressure(Maximum) 6000 PSI

Proof Pressure 9000 PSI

Burst Pressure 12000 PSI

Fatique Pressure(Maximum) 0-4000-0 PSI @3,000,000 Cycles

Fluid Temperature: -40°F to +212°FConstruction:

Head Nodular IronBowl Extruded SteelIndicators Consult FactoryElements Consult Factory

S.A.E. or Flange Ports Manifold Ports

Weight: Length 1 7.3 Lbs. 10.6 Lbs.

Length 2 9.3 Lbs. 12.6 Lbs.

Wiring Diagrams:

Electrical Ratings:Hirschman Connector without Lamps:

T - 250 or 110 VAC or 28 VDC Max.

Page 3: Oil Solutions · Oil Solutions 100/200/300 Series ... 3000psi 02QX FF 3 ≥200 >1000 >3000 >5000 INF INF 5 High 99.5 99.9 99.97 99.98 ... Hirschmann Connector Part Voltages

High Pressure Filters100/200/300 Series

Parker Hannifin CorporationHydraulic Filter DivisionMetamora, OH

High Performance New Generation100 Series FiltersThis rugged, compact filter has 25 GPM flow capability and 6000 PSI workingpressure. Our high pressure filters are specified worldwide for industrial, mobile,marine and mining applications.Arlon�s high pressure filters are the finest you can buy. Here is why:TruTell combined bypass valve and indicator.

1. High performance, low hysteresis bypass valve assures quick return to theclosed position following cold starts or other short-term bypass conditions.Result: the best filter performance and protection for your system. Thelocation of the bypass valve is 90° to the flow stream, which preventsunwanted valve operation and helps cushion the effect of system shocks(when compared with in-line valve location).

2. The bypass condition is indicated by the appearance of a red band under thetransparent dome. The indicator has 360° visibility for easy viewing.Several other indicator options are shown below.

BetaMaze� Media3. A break through in filter media technology. BetaMaze� provides great

efficiency with unmatched dirt holding capabilities. Absolute ratings of3 to 20 microns are available to meet any system requirement.

Other Features4. Port options include SAE straight thread or manifold mount.5. Bowl-into-head assembly provides positive sealing and easier servicing.

For complete information, see design features section.

Trutell Bypass Valve/Clogging IndicatorOver 30 years of testing valves of different configurationsled to the combined TruTell Metering spool valve andindicator. This design produces the best all aroundcharacteristics for stability, low hysteresis, minimalleakage and reliability.A bypass valve that closes quickly and completely isA bypass valve that closes quickly and completely isA bypass valve that closes quickly and completely isA bypass valve that closes quickly and completely isA bypass valve that closes quickly and completely isimportant because a filter in bypass offers no systemimportant because a filter in bypass offers no systemimportant because a filter in bypass offers no systemimportant because a filter in bypass offers no systemimportant because a filter in bypass offers no systemprotection, especially from large particles that canprotection, especially from large particles that canprotection, especially from large particles that canprotection, especially from large particles that canprotection, especially from large particles that cancause catastrophic failure.cause catastrophic failure.cause catastrophic failure.cause catastrophic failure.cause catastrophic failure.

The TruTell bypass valve and indicator assembly is aprecision machined constant area, metering spool designfrom which hysteresis effects have been virtuallyeliminated. See illustration and curve.

(A) 100 Series length 2 with electrical indicator(B) 100 Series length 1 with visual indicator(C) 100 Series length 1 manifold mounting

21

3

5

4

C

B

A

109

Page 4: Oil Solutions · Oil Solutions 100/200/300 Series ... 3000psi 02QX FF 3 ≥200 >1000 >3000 >5000 INF INF 5 High 99.5 99.9 99.97 99.98 ... Hirschmann Connector Part Voltages

High Pressure Filters100/200/300 Series

Parker Hannifin CorporationHydraulic Filter DivisionMetamora, OH110

BetaMaze� Media High Performance BetaMaze��High PerformanceWith Long LifeAfter years of research Arlonoffers its best filter media ever,BetaMaze�. The media is aspecial blend of inorganicmicrofibers formulated forunmatched dirt holding capacityand state of the art filtrationefficiency. The filter elementis multilayer constructionand wire mesh reinforcedon both sides. This providesexcellent fatigue resistanceand top performance underhigh differential pressure andpulsing flows.

The BetaMaze� Edge�Long LifeBecause of their exceptionaldirt holding capacity BetaMazeelements need to be changed lessfrequently than comparable sizedcompetitive elements. A real costsavings that pays dividends everyminute of operation.

An Element ForEvery ApplicationBetaMaze� elements are availablein high collapse ratings (3000 psi)in 3 and 15 micron absolute media.Cleanable elements are availablein high and low collapse strengthconfigurations with micron ratingsfrom 3 to 75 absolute. Consultfactory for availability.

Filtration Rating

Filter Type Media Code βββββx>200 βββββ3 βββββ6 βββββ10 βββββ12 βββββ20 βββββ25

3000psi 02QX FF 3 ≥200 >1000 >3000 >5000 INF INF5

High99.5 99.9 99.97 99.98

Collapse10QX 10 15 3 12 50 75 >2000 >5000

66.66 91.66 98.0 98.67 99.95 99.98

Filtration Rating

Filter Type Media Code βββββx>200 βββββ3 βββββ6 βββββ10 βββββ12 βββββ20 βββββ25

GDH3 20 3 ≥100 >300 >1500 >2000 >5000 INF99.0 99.67 99.93 99.95 99.98

7 290 psi GDH6 21 6 12 ≥100 >1000 >2000 >5000 INFCollapse 91.7 99.0 99.9 99.95 99.98

GDH10 22 10 8 22 ≥100 ≥200 >5000 INF87.5 95.4 99.0 99.5 99.98

GDH20 23 20 – 2 8 20 ≥100 ≥20050.0 87.5 95.0 99.0 99.5

Element efficiency in percent

Element Beta ratio βββββx

Multi-Pass Test Results to ISO 4572 (Time Weighted Average)

Point 1Point 1Point 1Point 1Point 1Competitive bypass valve designs withsignificantly different areas between theopen and closed position or high frictionsliding seals have high hysteresis. As aresult these bypass valves do not close asquickly as they should and a largepercentage of the fluid continues to bypassthe filter element completely after a coldstart up (usually anything below 68°F).

Point 2Point 2Point 2Point 2Point 2Most competitive bypass valvesdramatically limits filter assemblyperformance even with a good elementin the filter housing.

The TruTell design forces as much fluidas possible through the element even whenpartially open.

Point 3Point 3Point 3Point 3Point 3The TruTell bypass valve location is veryimportant. Our valve and indicatorcombination is situated near the outletport at right angles to the flow path. Inthis position it monitors only elementdifferential pressure. Undesirable leakageand premature bypass associated with inline valve locations are eliminated.This location also helps cushion the effectof system shocks that pass through in-linebypass valves virtually unaffected.

Point 4Point 4Point 4Point 4Point 4Our TruTell Bypass valve is magneticallycoupled to the indicator. This assures nofalse warning that element bypass willever occur. If the indicator actuates,an impending or bypass conditionexists period.

Unless the indicator is coupled to thebypass valve, it is impossible to accuratelyindicate bypass valve position under alloperating conditions.

Point 5Point 5Point 5Point 5Point 5Arlon offers the widest selection ofindicator types in the industry.

Visual types include:A. A 360° visibility non-latching typeB. A 360° visibility latching type (For

remote locations or flow on demandsystems, or where systems must beshut down to inspect the filter.)

Electrical indicators include:C. Visual electricalD. Electrical only

For electrical indicator connector optionssee Table 5 on back cover.

Page 5: Oil Solutions · Oil Solutions 100/200/300 Series ... 3000psi 02QX FF 3 ≥200 >1000 >3000 >5000 INF INF 5 High 99.5 99.9 99.97 99.98 ... Hirschmann Connector Part Voltages

High Pressure Filters100/200/300 Series

Parker Hannifin CorporationHydraulic Filter DivisionMetamora, OH111

Flow/Pressure Drop CurvesDisposable Elements - 100 Series

For Bypass Equipped Housings (290 psid min. collapse) For Non-bypass Housings (3000 psid min. collapse)

Fluid Conditions: Viscosity 140 SSU (30 cSt) and SP. Gr. 0.99 Note: Element ∆P is directly proportional to viscosity.

Find Filter Assembly Pressure Drop

Filter assembly ∆P is equal to the sum of element and housingpressure drops taken from the appropriate curves and adjustedfor operating viscosity and specific gravity.

Example:Filer Model: 174A-2N35-JZ120

Flow: 6 GPM

Viscosity: 78 SSU, Sp. Gr.: 0.88

Step 1. Correct element ∆∆∆∆∆P for viscosity.Element ∆P = 8 psi x 78SSU/140SSU = 4.4psi

Step 2. Correct housing ∆∆∆∆∆P for specific gravity.Housing ∆P = 5.0 psi x 0.88/0.88 = 5.0 psi

Step 3. Calculate assembly ∆∆∆∆∆P.Assy ∆P = 4.4 psi + 5.0 psi = 9.4 psi

0 5 201510

10

30

20

0

GPM

PS

ID

Length 1

0 25 7550LPM

2,0

1,5

1,0

0,5

0

BA

R

150-Z-110

150-

Z-1F

F

0 5 3025201510

10

30

20

0

GPM

PS

IDLength 2

0 25 1007550LPM

2,0

1,5

1,0

0,5

0

BA

R

150-Z-210

150-

Z-2F

F

Page 6: Oil Solutions · Oil Solutions 100/200/300 Series ... 3000psi 02QX FF 3 ≥200 >1000 >3000 >5000 INF INF 5 High 99.5 99.9 99.97 99.98 ... Hirschmann Connector Part Voltages

High Pressure Filters100/200/300 Series

Parker Hannifin CorporationHydraulic Filter DivisionMetamora, OH

DimensionsInches (mm)

100 Series

112

Page 7: Oil Solutions · Oil Solutions 100/200/300 Series ... 3000psi 02QX FF 3 ≥200 >1000 >3000 >5000 INF INF 5 High 99.5 99.9 99.97 99.98 ... Hirschmann Connector Part Voltages

High Pressure Filters100/200/300 Series

Parker Hannifin CorporationHydraulic Filter DivisionMetamora, OH113

Parts Breakdown100 Series Filter

Dust SealN72021 Nitrile

Upper Indicator to Head Seal*N93908 NitrileV93908 FluorocarbonE83908 EPR

Lower Indicator to Head Seal*N72014 NitrileV72014 FluorocarbonE82014 EPR

Element to Adapter SealN72116 NitrileV72116 FluorocarbonE82116 EPR

Head to Bowl Seal*N92145 NitrileV92145 FluorocarbonE82145 EPR

*Included in Seal Kit: 936053 Nitrile936055 Fluorocarbon936054 EPR

BowlLength Part Number

1 FF2410/4

2 FF3641/4

Electrical Actuator AssemblyHirschmann Connector

Part VoltagesCode Number Available

T FF3468 28 VDC, 250 VAC Max.

Non-Indicator Assembly Non-Bypass Plug Bypass Assy.

0N00-1 1N35-1

Electrical SubassemblyNon-Bypass Bypass

FF3283 FF3282

Head Assembly (Element Adapter included)Description Part Number

SAE-12 (11/16″- 12 Thread) 104-J

Manifold Ports 104-2-L

Element Kit

Length Disposable – All Fluids (Except Phosphate Ester)

3 µm abs. 6 µm abs. 10 µm abs. 20 µm abs.

1 170-Z-120 170-Z-121 170-Z-122 170-Z-1232 170-Z-220 170-Z-221 170-Z-222 170-Z-223

Disposable – High Collapse (3000 psid)3 µm absolute 15 µm absolute

1 150-Z-1FF 150-Z-110

2 150-Z-2FF 150-Z-210

Cleanable – High Collapse (3000 psid)6 µm absolute 20 µm absolute

1 140-Z-101 140-Z-1102 140-Z-201 140-Z-210

Cleanable – Corrosion Resistant Mesh40 µm absolute 75 µm absolute

1 190-Z-140 190-Z-1752 190-Z-240 190-Z-275

Vissual Indicator AssemblyBypass Valve No Bypass Valve

2N35-1 4N35-1Latching Latching

2L35-1 4L35-1

Page 8: Oil Solutions · Oil Solutions 100/200/300 Series ... 3000psi 02QX FF 3 ≥200 >1000 >3000 >5000 INF INF 5 High 99.5 99.9 99.97 99.98 ... Hirschmann Connector Part Voltages

High Pressure Filters100/200/300 Series

Parker Hannifin CorporationHydraulic Filter DivisionMetamora, OH

HOW TO ORDER 100 Series Filters:Select the desired symbol (in the correct position) to construct a model code.Assembly Example:

Element Example:

1 Steel/Nodular Iron

BOX 1: HOUSING MATERIALSymbol Description

4 High StrengthCleanable St. Steel

5 BetaMaze™ HighStrength Disposable

7 BetaMaze™Inorganic disposable

9 Corrosion resistantmesh-cleanable

BOX 2: FILTER/ELEMENT TYPESymbol Description

BOX 1 BOX 2 STD BOX 6 BOX 7 BOX 8 BOX 4

1 7 0 Z 1 23 A

A NitrileB EPR (Type S Elements)H Fluorocarbon

BOX 3: SEALSSymbol Description

S Skydrol-type All ratingsphosphate esters

Z All fluids* All ratings

*except phosphate esters

BOX 6: FLUID USESymbol Description Micron

1 Length 1 4, 5, 7, 92 Length 2 4, 5, 7, 9

BOX 7: ELEMENT LENGTHSymbol Description Type

01 6µ 410 20µ 4

FF 3µ 510 15µ 5

20 3µ 721 6µ 722 10µ 723 20µ 7

40 40µ 975 75µ 9

BOX 8: DEGREE OF FILTRATIONSymbol Absolute Rating Type

BOX 1 BOX 2 STD BOX 3 BOX 4 BOX 5 BOX 6 BOX 7 BOX 8

1 7 4 A 2N35 J Z 1 23

Bypass No BypassIndicator Type Indication @ Indication @

50 PSID (3.5 Bar) 50 PSID (3.5 Bar)

No Indicator 1N35 0N00

Visual 2N35 4N35

Visual-Latching 2L35 4L35

Electrical (T) 3T35 5T3528 VDC, 110-250 VAC

BOX 4: INDICATOR

L Manifold 1B G 1/2" BSP

(ISO 228) 1J S.A.E.-12

(1-1/16"-12Thread) 1

BOX 5: PORTFilter

Symbol Description Series

114

Page 9: Oil Solutions · Oil Solutions 100/200/300 Series ... 3000psi 02QX FF 3 ≥200 >1000 >3000 >5000 INF INF 5 High 99.5 99.9 99.97 99.98 ... Hirschmann Connector Part Voltages

High Pressure Filters100/200/300 Series

Parker Hannifin CorporationHydraulic Filter DivisionMetamora, OH115

SpecificationsHigh Prssure Hydraulic Filters - 200 Series

Flow Rating: 65 GPM

Pressure Rating:Operating Pressure(Maximum) 6000 PSI

Proof Pressure 9000 PSI

Burst Pressure 12000 PSI

Fatique Pressure(Maximum) 0-4000-0 PSI

@3,000,000 Cycles

Fluid Temperature: -40°F to +212°F

Construction:Head Nodular Iron

Bowl Extruded Steel

Indicators Consult Factory

Elements Consult Factory

Weight: S.A.E. or Flange Ports Manifold PortsLength 1 20 Lbs. 24 Lbs.

Length 2 22 Lbs. 26 Lbs.

Wiring Diagrams:

Features/Applications forHigh Pressure HydraulicFilters � 200 Series

■ Pressures to 6,000 PSI

■ Flows to 65 GPM

■ BetaMaze Elements -3 to 20 Micron Absolute

■ Disposable orRecleanable Elements

■ Reverse Flow Option

Electrical Ratings:Hirschman Connector without Lamps:

T - 250 or 110 VAC or 28 VDC Max.

Page 10: Oil Solutions · Oil Solutions 100/200/300 Series ... 3000psi 02QX FF 3 ≥200 >1000 >3000 >5000 INF INF 5 High 99.5 99.9 99.97 99.98 ... Hirschmann Connector Part Voltages

High Pressure Filters100/200/300 Series

Parker Hannifin CorporationHydraulic Filter DivisionMetamora, OH

High PerformanceNew Generation200 Series Filters

TrueTell Bypass Valve/Clogging IndicatorOver 30 years of testing valves of differentconfigurations led to the combined TruTell bypass valveand indicator. This design produces the best all aroundcharacteristics for stability, low hysteresis, minimalleakage and reliability.

A bypass valve that closes quickly and completelyis important because a filter in bypass offers nosystem protection, especially from large particlesthat can cause catastrophic failure.

The TruTell bypass valve and indicator assembly is aprecision machined design from which hysteresis effectshave been virtually eliminated. See curve.

(A) 200 Series length 2(B) 200 Series length 2 manifold mounting(C) 200 Series length 1 with visual latching indicator(D) 200 Series length 1 with dual electrical and visual indicators

A rugged modular design for applications to 6000 PSI and 65 GPM. Arlon�s highpressure filters are specified worldwide for industrial, mobile, marine andmining applications.Arlon�s high pressure filters are the finest you can buy. Here is why:

TruTell combined bypass valve and indicator.1. High performance, low hysteresis bypass valve assures quick return to the

closed position following cold starts or other short-term bypass conditions.Result: the best filter performance and protection for your system. Thelocation of the bypass valve is 90° to the flow stream, which preventsunwanted valve operation and helps cushion the effect of system shocks(when compared with in-line valve location).

2. The bypass condition is indicated by the appearance of a red band underthe transparent dome. The indicator has 360° visibility for easy viewing.Several other indicator options are shown below.

BetaMaze� Media3. A break-through in filter media technology. BetaMaze� provides great

efficiency with unmatched dirt holding capabilities. Absolute ratings of3 to 20 microns are available to meet any system requirement.

Other Features4. Port options include SAE straight thread, SAE 3000 or 6000 PSI flanges or

manifold mount.5. Bowl-into-head assembly provides positive sealing and easier servicing.6. A rugged, low pressure drop reverse flow valve is available.7. For complete information, see design features section.

116

21

3

5

4

D

B

C

A

00

20 40 60 80 100 120

50

100

150

200

FLOW, GPM

FLOW, LPM

0 100 200 300 400

∆ P, P

SI

∆P, B

AR6

4

2

8

10

12

0

50 PSID

73 PSID

Closing

Closing

Opening

Opening

Page 11: Oil Solutions · Oil Solutions 100/200/300 Series ... 3000psi 02QX FF 3 ≥200 >1000 >3000 >5000 INF INF 5 High 99.5 99.9 99.97 99.98 ... Hirschmann Connector Part Voltages

High Pressure Filters100/200/300 Series

Parker Hannifin CorporationHydraulic Filter DivisionMetamora, OH

BetaMaze� Media High Performance BetaMaze��High PerformanceWith Long LifeAfter years of research Arlonoffers its best filter media ever,BetaMaze�. The media is aspecial blend of inorganicmicrofibers formulated forunmatched dirt holding capacityand state of the art filtrationefficiency. The filter element ismultilayer construction and wiremesh reinforced on both sides.This provides excellent fatigueresistance and top performanceunder high differential pressureand pulsing flows.

The BetaMaze� Edge�Long LifeBecause of their exceptional dirtholding capacity BetaMazeelements need to be changed lessfrequently than comparable sizedcompetitive elements. A real costsavings that pays dividends everyminute of operation.

An Element ForEvery ApplicationBetaMaze� elements areavailable in high collapse ratings(3000 psi) in 3 and 15 micronabsolute media. Cleanableelements are available in highand low collapse strengthconfigurations with micron ratingsfrom 6 to 75 absolute. Consultfactory for availability.

Filtration Rating

Filter Type Media Code βββββx>200 βββββ3 βββββ6 βββββ10 βββββ12 βββββ20 βββββ25

3000psi 02QX FF 3 ≥200 >1000 >3000 >5000 INF INF5

High99.5 99.9 99.97 99.98

Collapse10QX 10 15 3 12 50 75 >2000 >5000

66.66 91.66 98.0 98.67 99.95 99.98

Filtration Rating

Filter Type Media Code βββββx>200 βββββ3 βββββ6 βββββ10 βββββ12 βββββ20 βββββ25

GDH3 20 3 ≥100 >300 >1500 >2000 >5000 INF99.0 99.67 99.93 99.95 99.98

7 290 psi GDH6 21 6 12 ≥100 >1000 >2000 >5000 INFCollapse 91.7 99.0 99.9 99.95 99.98

GDH10 22 10 8 22 ≥100 ≥200 >5000 INF87.5 95.4 99.0 99.5 99.98

GDH20 23 20 – 2 8 20 ≥100 ≥20050.0 87.5 95.0 99.0 99.5

Element efficiency in percent

Element Beta ratio Bx

Multi-Pass Test Results to ISO 4572 (Time Weighted Average)

Point 1Point 1Point 1Point 1Point 1Competitive bypass valve designs withsignificantly different areas between theopen and closed position or high frictionsliding seals have high hysteresis. As aresult these bypass valves do not close asquickly as they should and a largepercentage of the fluid continues to bypassthe filter element completely after a coldstart up (usually anything below 68°F).

Point 2Point 2Point 2Point 2Point 2Most competitive bypass valvesdramatically limits filter assemblyperformance even with a good element inthe filter housing.The TruTell design forces as much fluid aspossible through the element even whenpartially open.

Point 3Point 3Point 3Point 3Point 3The TruTell bypass valve location is veryimportant. Our valve and indicatorcombination is situated near the outletport at right angles to the flow path. Inthis position it monitors only elementdifferential pressure. Undesirable leakageand premature bypass associated with inline valve locations are eliminated.This location also helps cushion the effectof system shocks that pass through in-linebypass valves virtually unaffected.

Point 4Point 4Point 4Point 4Point 4Our TruTell Bypass valve is magneticallycoupled to the indicator. This assures nofalse warning that element bypass willever occur. If the indicator actuates, animpending or bypass condition existsperiod.Unless the indicator is coupled to thebypass valve, it is impossible to accuratelyindicate bypass valve position under alloperating conditions.

Point 5Point 5Point 5Point 5Point 5Arlon offers the widest selection ofindicator types in the industry.

Visual types include:A. A 360° visibility non-latching typeB. A 360° visibility latching type (For

remote locations or flow on demandsystems, or where systems must beshut down to inspect the filter.)

Electrical indicators include:C. Visual electricalD. Electrical and VisualE. Dual electrical

For electrical indicator connector optionssee Box 4 on page 126.

A BC D

E

117

Page 12: Oil Solutions · Oil Solutions 100/200/300 Series ... 3000psi 02QX FF 3 ≥200 >1000 >3000 >5000 INF INF 5 High 99.5 99.9 99.97 99.98 ... Hirschmann Connector Part Voltages

High Pressure Filters100/200/300 Series

Parker Hannifin CorporationHydraulic Filter DivisionMetamora, OH118

For Bypass Equipped Housings (290 psid min. collapse) For Non-bypass Housings (3000 psid min. collapse)

Fluid Conditions: Viscosity 140 SSU (30 cSt) and SP. Gr. 0.88 Note: Element ∆P is directly proportional to viscosity.

Find Filter Assembly Pressure Drop

Filter assembly ∆P is equal to the sum of element and housing pressuredrops taken from the appropriate curves and adjustedfor operating viscosity and specific gravity.

Example:Filer Model: 274A-BV50-JZ222Flow: 50 GPMViscosity: 225 SSU, Sp. Gr.: 1.0Step 1. Correct element ∆∆∆∆∆P for viscosity.

Element ∆P = 6 psi x 225SSU/140SSU = 9.6psiStep 2. Correct housing ∆∆∆∆∆P for specific gravity.

Housing ∆P = 15 psi x 1.0/0.88 = 17.0 psiStep 3. Calculate assembly ∆∆∆∆∆P.

Assy ∆P = 9.6 psi + 17.0 psi = 26.6 psiAlternate steps for filter with reverse flow valve.Step 3. Correct reverse flow

Valve ∆P for specific gravityRFV ∆P = 4 psi x 1.0/0.88 = 4.5 psi

Step 4. Calculate assembly∆∆∆∆∆P = 9.6 psi + 17.0 psi + 4.5 psi = 31.1 psi

NOTE: Housing and reverse flow valve ∆P are directly proportional tospecific gravity.

Flow/Pressure Drop CurvesDisposable Elements - 200 Series

0 10 6050403020

10

30

20

0

GPM

PS

ID

Length 1

0 50 200150100LPM

2,0

1,5

1,0

0,5

0

BA

R250-

Z-110

250-

Z-1F

F

0 10 6050403020

10

30

20

0

GPM

PS

IDLength 2

0 50 200150100LPM

2,0

1,5

1,0

0,5

0

BA

R

250-Z-210

250-Z-2FF

Page 13: Oil Solutions · Oil Solutions 100/200/300 Series ... 3000psi 02QX FF 3 ≥200 >1000 >3000 >5000 INF INF 5 High 99.5 99.9 99.97 99.98 ... Hirschmann Connector Part Voltages

High Pressure Filters100/200/300 Series

Parker Hannifin CorporationHydraulic Filter DivisionMetamora, OH

DimensionsInches (mm)200 Series

Dim Port Option‘F’ ‘T’

A 0.937" 1.031"23.8mm 26.2mm

B 2.000" 2.062"50.8mm 52.4mm

Reverse Flow Valve � Better Three WaysFor hydrostatic drives and other systems where reverseflow is required a valve is incorporated which allows fluidto pass through the element in one direction but to bypassthe element when flow is reversed. (See diagrams).

1. Rugged one piece steel body design that is built to last.Unlike stamped metal or aluminum designs. Arlon�sReverse Flow Valve (RFV) is a spool/ disc valve cagedin a high strength machined steel body. This greatlyreduces the risk of valve failure and resultant filter orcomponent damage.

2. Low pressure drop � the spool/disc design keepssystem pressure losses at a minimum withoutsacrificing reliability.

3. Our modular design means easy change over orreplacement. The reverse flow valve threads directlyinto the filter head, replacing the standard elementadapter. For customers with more that one applicationor for system conversions, multiple applications fromthe dame hardware means less inventory.

119

Page 14: Oil Solutions · Oil Solutions 100/200/300 Series ... 3000psi 02QX FF 3 ≥200 >1000 >3000 >5000 INF INF 5 High 99.5 99.9 99.97 99.98 ... Hirschmann Connector Part Voltages

High Pressure Filters100/200/300 Series

Parker Hannifin CorporationHydraulic Filter DivisionMetamora, OH120

Element KitLength Disposable – All Fluids

3 µm abs. 6 µm abs. 10 µm abs. 20 µm abs.

1 270-Z-120 270-Z-121 270-Z-122 270-Z-123

2 270-Z-220 270-Z-221 270-Z-222 270-Z-223High Collapse – Disposable (3000 psid)

3 µm absolute 15 µm absolute

1 250-Z-1FFH 250-Z-110H

2 250-Z-2FFH 250-Z-210H

High Collapse – Cleanable (3000 psid)

6 µm absolute 20 µm absolute

1 240-Z-101 240-Z-110

2 240-Z-201 240-Z-210

Cleanable

40 µm absolute 75 µm absolute

1 290-Z-140 290-Z-175

2 290-Z-240 290-Z-275

*Included in Seal Kit: 936057 Nitrile936058 EPR936059 Fluorocarbon

Electrical SubassemblyBypass Valve Non-Bypass

90.34.000.29 (73 psid) 90.34.000.27 (73 psid)

90.34.000.28 (50 psid) 90.34.000.26 (50 psid)

Non-Indicator AssemblyNon-Bypass Plug Bypass Assy.

P000-2 BN50-2BN35-2

BowlLength Part Number

1 FF4282

2 FF4283

Dust SealN72021 Nitrile

Indicator Back-Up RingFF2957

Bypass Housing to Head Seal*N72022 NitrileV72022 FluorocarbonE82022 EPR

Adapter to Head Seal*N72122 NitrileV72122 FluorocarbonE82122 EPR

Reverse FlowValve AssemblyFF3675

Element to HeadAdapter AssemblyFF3571

Element to Adapter Seal81.10.150.92 Nitrile81.10.152.92 Fluorocarbon81.10.161.92 EPR

Head to Bowl Seal*N92235 NitrileV92235 FluorocarbonE82235 EPR

Head to Bowl Back-Up RingFF3141

Parts Breakdown200 Series Filter

HEADDescription Part Number

SAE-12 (11/16″ – 12 Thread) 204-S

SAE-16 (15/16″ – 12 Thread) 204-J

SAE-20 (15/8″ – 12 Thread) 204-H

SAE 6000 PSI 3/4″ Flange, Code 62 204-F

SAE 3000 PSI 1″ Flange, Code 61 204-T

Manifold Adapter 204-V

Visual Indicator AssemblyBypass Valve No Bypass Valve

BV50-2 NV50-2BV35-2 NV35-2

Latching LatchingBL50-2 NL50-2BL35-2 NL35-2

Electrical Actuator AssemblyHirschmann Connector

Part VoltagesCode Number Available

T FF3468 28 VDC, 250 VAC Max.

Page 15: Oil Solutions · Oil Solutions 100/200/300 Series ... 3000psi 02QX FF 3 ≥200 >1000 >3000 >5000 INF INF 5 High 99.5 99.9 99.97 99.98 ... Hirschmann Connector Part Voltages

High Pressure Filters100/200/300 Series

Parker Hannifin CorporationHydraulic Filter DivisionMetamora, OH121

HOW TO ORDER 200 Series Filters:Select the desired symbol (in the correct position) to construct a model code.Assembly Example:

Element Example:

4 High StrengthCleanable St. Steel

7 BetaMaze™Inorganic disposable

5 High Strength Disposable9 Corrosion resistant

mesh-cleanable

BOX 1: FILTER/ELEMENT TYPESymbol Description

STD BOX 1 STD BOX 6 BOX 7 BOX 8 BOX 3

2 7 0 Z 1 23 A

A NitrileB EPR (Type S Elements)H Fluorocarbon

BOX 3: SEALSSymbol Description

STD BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6 BOX 7 BOX 8

2 7 4 A BV50 S Z 1 23

BYPASS BYPASS NO BYPASS NO BYPASS

Indicator Type INDICATION @ INDICATION @ INDICATION @ INDICATION @50 PSID (3.5 BAR) 73 PSID (5.0 BAR) 50 PSID (3.5 BAR) 73 PSID (5.0 BAR)

NO INDICATOR BN35 BN50 P000 P000

VISUAL BV35 BV50 NV35 NV50

VISUAL-LATCHING BL35 BL50 NL35 NL50

ELECTRICAL (T) BE35 BE50 NE35 NE5028 VDC, 110-250 VAC

BOX 4: INDICATOR

4 Normal2 With Reverse Flow Valve

BOX 2: FILTER FLOWSymbol Description

S SAE-12 (1-1/16"-12 Thread) 2

J SAE-16 (1-5/16"-12 Thread) 2H SAE-20 (1-5/8"-12 Thread) 2F 3/4" SAE Flange, Code 62 2T 1" SAE Flange, Code 61 2V Manifold Adaptor 2

BOX 5: PORT OPTIONSFilter

Symbol Description Ser.

S Phosphate esters All(Skydrol) ratings

Z All fluids Allratings

BOX 6: ELEMENT TYPEAbsoluteRatings

Symbol Element Types Micron 1 Length 1 4, 5, 7, 92 Length 2 4, 5, 7, 9

BOX 7: ELEMENT LENGTHSymbol Description Type

01 6µ 410 20µ 4

FF 3µ 510 15µ 5

20 3µ 721 6µ 722 10µ 723 20µ 7

40 40µ 975 75µ 9

BOX 8: DEGREE OF FILTRATIONSymbol Absolute Rating Type

Dual Indicator Codes:BEE50 - Bypass with double electrical indicatorsNEE50 - No bypass with double electrical indicatorsBEV50 - Bypass with (1) mechanical visual (50 psid) and (1) electrical indicator (73 psid)NEV50 - No bypass with (1) mechanical visual (50 psid) and (1) electrical indicator (73 psid)

Note: Dual Indicators are not available with Port Option “V”

Page 16: Oil Solutions · Oil Solutions 100/200/300 Series ... 3000psi 02QX FF 3 ≥200 >1000 >3000 >5000 INF INF 5 High 99.5 99.9 99.97 99.98 ... Hirschmann Connector Part Voltages

High Pressure Filters100/200/300 Series

Parker Hannifin CorporationHydraulic Filter DivisionMetamora, OH

Specifications

High Pressure HydraulicFilters — 300 Series

Max Flow Rating: 120 GPM

Pressure Rating:Operating Pressure(Maximum) 6000 PSI

Proof Pressure 9000 PSI

Burst Pressure 12000 PSI

Fatique Pressure(Maximum) 0-4000-0 PSI

@3,000,000 Cycles

122

Applications/Features forHigh Pressure HydraulicFilters � 300 Series■ Pressures to 6,000 PSI

■ Flows to 120 GPM

■ BetaMaze� Elements -3 to 20 Micron Absolute

■ Disposable orRecleanable Elements

■ Reverse Flow Options

Electrical Ratings:Hirschman Connector without Lamps:

T - 250 or 110 VAC or 28 VDC Max.

Fluid Temperature: -40°F to +212°F

Construction:Head Nodular Iron

Bowl Extruded Steel

Indicators Consult Factory

Elements Consult Factory

Weight:S.A.E. or Manifold

Flange Ports PortsLength 1 31 Lbs. 36 Lbs.

Length 2 37.5 Lbs. 42.5 Lbs.

Length 3 44 Lbs. 49 Lbs.

Wiring Diagrams:

Page 17: Oil Solutions · Oil Solutions 100/200/300 Series ... 3000psi 02QX FF 3 ≥200 >1000 >3000 >5000 INF INF 5 High 99.5 99.9 99.97 99.98 ... Hirschmann Connector Part Voltages

High Pressure Filters100/200/300 Series

Parker Hannifin CorporationHydraulic Filter DivisionMetamora, OH123

High PerformanceNew Generation300 Series Filters

TruTell Bypass Valve/Clogging IndicatorOver 30 years of testing valves of differentconfigurations led to the combined TruTell bypass valveand indicator. This design produces the best all aroundcharacteristics for stability, low hysteresis, minimalleakage and reliability.

A bypass valve that closes quickly and completely isA bypass valve that closes quickly and completely isA bypass valve that closes quickly and completely isA bypass valve that closes quickly and completely isA bypass valve that closes quickly and completely isimportant because a filter in bypass offers no systemimportant because a filter in bypass offers no systemimportant because a filter in bypass offers no systemimportant because a filter in bypass offers no systemimportant because a filter in bypass offers no systemprotection, especially from large particles that canprotection, especially from large particles that canprotection, especially from large particles that canprotection, especially from large particles that canprotection, especially from large particles that cancause catastrophic failure.cause catastrophic failure.cause catastrophic failure.cause catastrophic failure.cause catastrophic failure.

The TruTell bypass valve and indicator assembly is aprecision machined design from which hysteresis effectshave been virtually eliminated. See curve.

(A) 300 Series length 3(B) 300 Series length 3 manifold mounting(C) 300 Series length 1 with dual electrical and visual indicators(D) 300 Series length 2 with visual electrical indicator

A rugged modular design for applications to 6000 PSI and 120 GPM. Arlon�s highpressure filters are specified worldwide for industrial, mobile, marine andmining applications.Arlon�s high pressure filters are the finest you can buy. Here is why:

TruTell combined bypass valve and indicator.1. High performance, low hysteresis bypass valve assures quick return to the

closed position following cold starts or other short-term bypass conditions.Result: the best filter performance and protection for your system. Thelocation of the bypass valve is 90° to the flow stream, which preventsunwanted valve operation and helps cushion the effect of system shocks(when compared with in-line valve location).

2. The bypass condition is indicated by the appearance of a red band underthe transparent dome. The indicator has 360° visibility for easy viewing.Several other indicator options are shown below.

BetaMaze� Media3. A break through in filter media technology. BetaMaze� provides great

efficiency with unmatched dirt holding capabilities. Absolute ratings of3 to 20 microns are available to meet any system requirement.

Other Features4. Port options include SAE straight thread SAE 3000 or 6000 PSI flanges or

manifold mount.5. Bowl-into-head assembly provides positive sealing and easier servicing.6. A rugged, low pressure drop reverse flow valve is available.7. For complete information, see design features section.

21

3

5

4

D

B

C

A

00

20 40 60 80 100 120

50

100

150

200

FLOW, GPM

FLOW, LPM

0 100 200 300 400

∆ P, P

SI

∆P, B

AR6

4

2

8

10

12

0

50 PSID

73 PSID

Closing

Closing

Opening

Opening

Page 18: Oil Solutions · Oil Solutions 100/200/300 Series ... 3000psi 02QX FF 3 ≥200 >1000 >3000 >5000 INF INF 5 High 99.5 99.9 99.97 99.98 ... Hirschmann Connector Part Voltages

High Pressure Filters100/200/300 Series

Parker Hannifin CorporationHydraulic Filter DivisionMetamora, OH124

BetaMaze� Media High Performance BetaMaze��High PerformanceWith Long LifeAfter years of research Arlonoffers its best filter media ever,BetaMaze�. The media is aspecial blend of inorganicmicrofibers formulated forunmatched dirt holding capacityand state of the art filtrationefficiency. The filter element ismultilayer construction and wiremesh reinforced on both sides.This provides excellent fatigueresistance and top performanceunder high differential pressureand pulsing flows.

The BetaMaze� Edge�Long LifeBecause of their exceptional dirtholding capacity BetaMazeelements need to be changed lessfrequently than comparable sizedcompetitive elements. A real costsavings that pays dividends everyminute of operation.

An Element ForEvery ApplicationBetaMaze elements are availablein high collapse ratings (3000 psi)in 6 and 15 micron absolutemedia. Cleanable elements areavailable in high and low collapsestrength configurations withmicron ratings from 6 to 75absolute. Consult factory foravailability.

Filtration Rating

Filter Type Media Code βββββx>200 βββββ3 βββββ6 βββββ10 βββββ12 βββββ20 βββββ25

3000psi 02QX FF 3 ≥200 >1000 >3000 >5000 INF INF5

High99.5 99.9 99.97 99.98

Collapse10QX 10 15 3 12 50 75 >2000 >5000

66.66 91.66 98.0 98.67 99.95 99.98

Filtration Rating

Filter Type Media Code βββββx>200 βββββ3 βββββ6 βββββ10 βββββ12 βββββ20 βββββ25

GDH3 20 3 ≥100 >300 >1500 >2000 >5000 INF99.0 99.67 99.93 99.95 99.98

7 290 psi GDH6 21 6 12 ≥100 >1000 >2000 >5000 INFCollapse 91.7 99.0 99.9 99.95 99.98

GDH10 22 10 8 22 ≥100 ≥200 >5000 INF87.5 95.4 99.0 99.5 99.98

GDH20 23 20 – 2 8 20 ≥100 ≥20050.0 87.5 95.0 99.0 99.5

Element efficiency in percent

Element Beta ratio βββββx

Multi-Pass Test Results to ISO 4572 (Time Weighted Average)

Point 1Point 1Point 1Point 1Point 1Competitive bypass valve designs withsignificantly different areas between theopen and closed position or high frictionsliding seals have high hysteresis. As aresult these bypass valves do not close asquickly as they should and a largepercentage of the fluid continues to bypassthe filter element completely after a coldstart up (usually anything below 68°F).

Point 2Point 2Point 2Point 2Point 2Most competitive bypass valvesdramatically limits filter assemblyperformance even with a good element inthe filter housing.The TruTell design forces as much fluid aspossible through the element even whenpartially open.

Point 3Point 3Point 3Point 3Point 3The TruTell bypass valve location is veryimportant. Our valve and indicatorcombination is situated near the outletport at right angles to the flow path. Inthis position it monitors only elementdifferential pressure. Undesirable leakageand premature bypass associated with inline valve locations are eliminated.This location also helps cushion the effectof system shocks that pass through in-linebypass valves virtually unaffected.

Point 4Point 4Point 4Point 4Point 4Our TruTell Bypass valve is magneticallycoupled to the indicator. This assures nofalse warning that element bypass willever occur. If the indicator actuates, animpending or bypass condition existsperiod.Unless the indicator is coupled to thebypass valve, it is impossible to accuratelyindicate bypass valve position under alloperating conditions.

Point 5Point 5Point 5Point 5Point 5Arlon offers the widest selection ofindicator types in the industry.

Visual types include:A. A 360° visibility non-latching typeB. A 360° visibility latching type (For

remote locations or flow on demandsystems, or where systems must beshut down to inspect the filter.)

Electrical indicators include:C. Visual electricalD. Electrical and VisualE. Dual electrical

For electrical indicator connector optionssee Table 5 on back cover.

A BC D

E

Page 19: Oil Solutions · Oil Solutions 100/200/300 Series ... 3000psi 02QX FF 3 ≥200 >1000 >3000 >5000 INF INF 5 High 99.5 99.9 99.97 99.98 ... Hirschmann Connector Part Voltages

High Pressure Filters100/200/300 Series

Parker Hannifin CorporationHydraulic Filter DivisionMetamora, OH125

Flow/Pressure Drop CurvesDisposable Elements - 300 Series

For Bypass Equipped Housings (290 psid min. collapse) For Non-bypass Housings (3000 psid min. collapse)

Fluid Conditions: Viscosity 140 SSU (30 cSt) and SP. Gr. 0.88 Note: Element ∆P is directly proportional to viscosity.

Find Filter Assembly Pressure DropFilter assembly ∆P is equal to the sum of element and housing pressuredrops taken from the appropriate curves and adjustedfor operating viscosity and specific gravity.

Example:Filer Model: 374A-BV50-FL223Flow: 120 GPMViscosity: 225 SSU, Sp. Gr.: 1.0

Step 1. Correct element ∆∆∆∆∆P for viscosity.Element ∆P = 7 psi x 225SSU/140SSU = 11.2psi

Step 2. Correct housing ∆∆∆∆∆P for specific gravity.Housing ∆P = 27 psi x 1.0/0.88 = 30.7 psi

Step 3. Calculate assembly ∆∆∆∆∆P.Assy ∆P = 11.2 psi + 30.7 psi = 41.9 psi

0 20 806040

10

30

20

0

GPM

PS

ID

Length 1

0 100 300200LPM

2,0

1,5

1,0

0,5

0

BA

R350-Z-110

350-

Z-1F

F

0 20 120100806040

10

30

20

0

GPM

PS

ID

Length 2

0 100 400300200LPM

2,0

1,5

1,0

0,5

0

BA

R

350-Z-210

350-

Z-2F

F

0 20 120100806040

10

30

20

0

GPM

PS

IDLength 3

0 100 400300200LPM

2,0

1,5

1,0

0,5

0

BA

R

350-Z-310

350-

Z-3F

F

Page 20: Oil Solutions · Oil Solutions 100/200/300 Series ... 3000psi 02QX FF 3 ≥200 >1000 >3000 >5000 INF INF 5 High 99.5 99.9 99.97 99.98 ... Hirschmann Connector Part Voltages

High Pressure Filters100/200/300 Series

Parker Hannifin CorporationHydraulic Filter DivisionMetamora, OH

Dimensions300 SeriesInches (mm)

Dim Port Option‘F’ ‘T’

A 1.250" 1.406"31.7mm 35.7mm

B 2.625" 2.750"66.7mm 69.8mm

Reverse Flow Valve � Better Three WaysFor hydrostatic drives and other systems where reverse flowis required a valve is incorporated which allows fluid to passthrough the element in one direction but to by-pass theelement when flow is reversed. (See diagrams).

1. Rugged one piece steel body design that is built to last.Unlike stamped metal or aluminum designs. Arlon�sReverse Flow Valve (RFV) is a spool/ disc valve cagedin a high strength machined steel body. This greatlyreduces the risk of valve failure and resultant filteror component damage.

2. Low pressure drop � the spool/disc design keepssystem pressure losses at a minimum withoutsacrificing reliability.

3. Our modular design means easy change over orreplacement. The reverse flow valve threads directlyinto the filter head, replacing the standard elementadapter. For customers with more that one applicationor for system conversions, multiple applications fromthe dame hardware means less inventory.

126

Page 21: Oil Solutions · Oil Solutions 100/200/300 Series ... 3000psi 02QX FF 3 ≥200 >1000 >3000 >5000 INF INF 5 High 99.5 99.9 99.97 99.98 ... Hirschmann Connector Part Voltages

High Pressure Filters100/200/300 Series

Parker Hannifin CorporationHydraulic Filter DivisionMetamora, OH

*Included in Seal Kit: 936060 Nitrile936061 EPR936062 Fluorocarbon

Non-Indicator AssemblyNon-Bypass Plug Bypass Assy.

P000-2BN50-2BN35-2

Dust SealN72021 Nitrile

Indicator Back-Up RingFF2957

Indicator to Head Seal*N7022 NitrileV72022 FluorocarbonE82022 EPR

Adapter to Head Seal*N72128 NitrileV72128 FluorocarbonE82128 EPR

Reverse FlowValve AssemblyFF3677

Element to HeadAdapter AssemblyFF3572

Element to Adapter Seal*N72225 NitrileV72225 FluorocarbonE82225 EPR

Head to Bowl Seal*N92346 NitrileV92346 FluorocarbonE82346 EPR

Head to Bowl Back-Up RingFF3142

Filter Parts Breakdown300 Series

HeadDescription Part Number

SAE-20 (15/8″ – 12 Thread) 304-S

SAE 6000 PSI 11/4″ Flange, Code 62 304-F

SAE 3000 PSI 1½″ Flange, Code 61 304-TManifold Adapter 304-V

Element KitLength Disposable – All Fluids

3 µm abs. 6 µm abs. 10 µm abs. 20 µm abs.

1 370-Z-120 370-Z-121 370-Z-122 370-Z-123

2 370-Z-220 370-Z-221 370-Z-222 370-Z-223

3 370-Z-320 370-Z-321 370-Z-322 370-Z-323

Disposable – High Collapse (3000 psid)

3 µm absolute 15 µm absolute

1 350-Z-1FFH 350-Z-110H

2 350-Z-2FFH 350-Z-210H

3 350-Z-3FFH 350-Z-310H

Cleanable – High Collapse (3000 psid)

6 µm absolute 20 µm absolute

1 340-Z-101 340-Z-110

2 340-Z-201 340-Z-210

3 340-Z-301 340-Z-310

Cleanable – Mesh

40 µm absolute 75 µm absolute

1 390-Z-140 390-Z-175

2 390-Z-240 390-Z-275

3 390-Z-340 390-Z-375

BowlLength Part Number

1 FF4287

2 FF4288

3 FF4289

ELECTRICAL SUBASSEMBLYBypass Valve Non-Bypass

90.34.000.29, 73 PSID 90.34.000.27, 73 PSID

90.34.000.28, 50 PSID 90.34.000.26, 50 PSID

127

Visual Indicator AssemblyBypass Valve No Bypass Valve

BV50-2 NV50-2

BV35-2 NV35-2

Latching Latching

BL50-2 NL50-2

BL35-2 NL35-2

Electrical Actuator AssemblyHirschmann Connector

Part VoltagesCode Number Available

T FF3468 28 VDC, 250 VAC Max.

Page 22: Oil Solutions · Oil Solutions 100/200/300 Series ... 3000psi 02QX FF 3 ≥200 >1000 >3000 >5000 INF INF 5 High 99.5 99.9 99.97 99.98 ... Hirschmann Connector Part Voltages

High Pressure Filters100/200/300 Series

Parker Hannifin CorporationHydraulic Filter DivisionMetamora, OH

HOW TO ORDER 300 Series Filters:Select the desired symbol (in the correct position) to construct a model code.Assembly Example:

Element Example:

4 High StrengthCleanable St. Steel

7 BetaMaze™Inorganic disposable

5 High Strength Disposable9 Corrosion resistant

mesh-cleanable

BOX 1: FILTER/ELEMENT TYPESymbol Description

STD BOX 1 STD BOX 6 BOX 7 BOX 8 BOX 3

3 7 0 Z 1 23 A

A NitrileB EPR (Type S elements)H Fluorocarbon

BOX 3: SEALSSymbol Description

STD BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6 BOX 7 BOX 8

3 7 4 A BV50 S Z 1 23

4 Normal2 With Reverse Flow Valve

BOX 2: FILTER FLOWSymbol Description

BOX 5: PORT OPTIONSSymbol Description

S SAE-20 (1-5/8"-12 Thread)

F S.A.E. –6000PSI 1-¼” Flange

T S.A.E. –3000PSI 1-½” Flange

V Manifold Adapter

S Phosphate Esters All ratings(Skydrol)

Z All fluids All ratings

BOX 6: ELEMENT TYPEAbsoluteRatings

Symbol Element Types Micron 1 Length 1 4, 5, 7, 92 Length 2 4, 5, 7, 93 Length 3 4, 5, 7,9

BOX 7: ELEMENT LENGTHSymbol Description Type

01 6µ 410 20µ 4

FF 3µ 510 15µ 5

20 3µ 721 6µ 722 10µ 723 20µ 7

40 40µ 975 75µ 9

BOX 8: DEGREE OF FILTRATIONSymbol Absolute Rating Type

BYPASS BYPASS NO BYPASS NO BYPASS

Indicator Type INDICATION @ INDICATION @ INDICATION @ INDICATION @50 PSID (3.5 BAR) 73 PSID (5.0 BAR) 50 PSID (3.5 BAR) 73 PSID (5.0 BAR)

NO INDICATOR BN35 BV50 P000 P000

VISUAL BV35 BV50 NV35 NV50

VISUAL-LATCHING BL35 BL50 NL35 NL50

ELECTRICAL (T) BE35 BE50 NE35 NE5028 VDC, 110-250 VAC

BOX 4: INDICATOR

Dual Indicator Codes:BEE50 - Bypass with double electrical indicatorsNEE50 - No bypass with double electrical indicatorsBEV50 - Bypass with (1) mechanical visual (50 psid) and (1) electrical indicator (73 psid)NEV50 - No bypass with (1) mechanical visual (50 psid) and (1) electrical indicator (73 psid)

Note: Dual Indicators are not available with Port Option “V”

128