Oil Analysis Technical GuideThe next generation in oil analysis exclusively from
ConocoPhillips Lubricants
Lubricants
-
8/10/2019 Oil Analysis guide and sampling procedure.pdf
2/28
-
8/10/2019 Oil Analysis guide and sampling procedure.pdf
3/28
1
Table of Contents
2
Laboratories
3
Introduction
4
Viscosity
6
Water/Coolant Contamination
7Fuel Dilution
8
Solids
9
Fuel Soot
10
Oxidation11
Nitration
12
Total Acid Number (TAN)
13
Total Base Number (TBN)
14
Particle Count
16/17
Wear Metals/Elemental Analysis
18Infrared Analysis
19/20
Typical Paper Analysis Test Report
21
Quality Equipment Oil AnalysisProgram
22/23Oil Sampling Procedures
ConocoPhillips Lubricants600 N. Dairy Ashford
2W-9000Houston, TX 77079http://lubricants.conocophillips.com
AnalysisPlusSupportBasic Testing: Lab One 866-652-2663Premium Testing: POLARIS Laboratories 866-341-4396
Staveley Services 877-645-5221
Technical Services Hotline1-800-766-0050
Customer Service Center1-800-640-1956 Monday-Friday, 7:30 a.m-5:00 p.m. C.S.T.
-
8/10/2019 Oil Analysis guide and sampling procedure.pdf
4/28
2
Staveley
Staveley
Staveley
Staveley
Staveley
Staveley
Staveley
Staveley P
olaris
Polaris
Polaris
LabO
ne
AnalysisPlusParticipating Laboratory Locations
Customer Selects LaboratoryCompany and Location
-
8/10/2019 Oil Analysis guide and sampling procedure.pdf
5/28
3
Oil analysis is a series of laboratory
tests used to evaluate the condition oflubricants and equipment components.By studying the results of the oil analysis
tests, a determination ofequipment/component condition canbe made. Primarily, this is possiblebecause of the cause- and-effectrelationship of the condition of thelubricant to the condition of the
component sampled. Many of thesecause-and-effect situations are outlinedin this manual.
Oil performs several vital functionswith many of them being interrelated.The ability of the oil to perform asdesigned can be determined by oilanalysis. Following is a list of someprimary lubricant functions that can beevaluated:
Friction control Corrosion controlContaminant control Shock controlHydraulic pressure Wear controlTemperature control Sealing function
The inspection or analysis oflubricating oil has been used to check
and evaluate the internal condition ofoil-lubricated equipment since thebeginning of the industrial age. Earlymethods included smelling the oil todetect the sour odor of excess acidity,rubbing it between finger tips to checklubricity, and observing its color andclarity for signs of contamination.
Today, oil analysis programsuse modern technology andlaboratory instruments to determineequipment condition and lubricant
How does the AnalysisPlus
Program work?
The program is based on fourcomponents:
Take oil samples from sumps orreservoirs of equipment at specificintervals;
Mail the oil samples to thelaboratory, where a series of testsare performed;
Test results are then evaluated todetermine the condition of theequipment;
Test results and recommendations
are provided to your maintenancepersonnel. This information is used tomonitor equipment condition and toassist in controlling operating costs.
How to get the most fromyourAnalysisPlusProgram?
This manual has been developed toassist in increasing your knowledge ofoil analysis. Explanations of routine
tests are provided together with cause-and-effect troubleshooting charts andrecommended solutions to problems.Use this information to get the mostbenefit from the program.
serviceability. Oil analysis uses state of
the art equipment and techniques toprovide the user with invaluableinformation leading to greaterequipment reliability.
Introduction
-
8/10/2019 Oil Analysis guide and sampling procedure.pdf
6/28
4
Viscosity is one of the most
important properties of lubricating oil.Viscosity is a measurement ofresistance to flow at a specific
temperature in relation to time. Thetwo most common temperatures forlubricating oil viscosity are 40C and100C. Viscosity is normally evaluatedwith a kinematic method and reportedin centistokes (cSt). In used oil analysis,
the used oils viscosity is compared tothat of the new oil to determinewhether excessive thinning or
thickening has occurred.Viscosity Index (VI) is the change in
flow rate of a lubricant with respect totemperature. Oil with a high VI resiststhinning at high temperatures. Use ofhigh VI oil is recommended in enginesand other systems that operate atelevated temperatures.
Cause
Effect
Solution
Low Viscosity Engine overheating Poor lubrication Metal-to-metal
contact Increased operating
costs
Evaluate equipmentuse vs. design
Evaluate operatingconditions
Use trainedoperators
Change oil andfilters
Check for loosefuel crossover lines
Viscosity
Check air-to-fuel ratio Check for incorrect
oil grade Inspect internal seals Check operating
temperature Check with lube
supplier for advice Check for leaking
injectors
High Viscosity Increased operating
costsEngine overheating Restricted oil flow Accelerated wear Oil filter by-passed Harmful
deposits/sludge
High Viscosity Contamination soot/
solids Incomplete
combustion-A/F ratio Oxidation degradation Leaking head gaskets
Extended oil draininterval High operating
temperature Improper oil grade
Low Viscosity Additive shear Fuel dilution Improper oil grade
-
8/10/2019 Oil Analysis guide and sampling procedure.pdf
7/28
5
70
60
50
40
30
20
10
9
8
7
6
5
4
15
32
22
46
68
100
150
220
320
460
680
1500
90
190
140
110
85
80
250
10 000
8000
6000
5000
4000
3000
2000
1500
1000
800
600
500
400
300
200
150
100
80
60
50
40
35
32
70
300
200
100
90
80
70
60
55
50
45
2000
1000
800
600
500
400
300
200
80
100
60
50
40
30
20
10
6
8
5
4
3
2
KINEMATIC
VISCOSITIES
SAYBOLT
VISCOSITIES
cSt/
40C
cSt/
100C
SUS/
100F
SUS/
210F
8A
9
8
7
6
5
4
3
2
1
AGMA
GRADES
SAE GRADES
GEAR OILS
10
7
5
3
2
1000
40
SAE GRADES
CRANKCASE
OILS
ISO
VISCOSITY
GRADE
60
50
40
30
20
10W
Viscosities can be related horizontally only.
Viscosities based on 96 VI single grade oils.
ISO andAGMA Grades are specified at 40C.
Kinematic viscosities are shown at 40C and100C in cSt and equivalent viscosities at 100Fand 210F in SUS.
0W/5W
Rule-of-Thumb:The comparable ISO grade of a given product whose viscosity is greater than
100 SUS at 100F if known can be determined by using the following conversion formula:
SUS @ 100F 5 = cSt @ 40C
Viscosity Grading Systems
http://lubricants.conocophillips.com
U.S. Technical Services Hotline: 1-800-766-0050
Copyright 2006 ConocoPhillips Company, Phillips 66, Conoco, 76 and Kendall logos are registered trademarks of ConocoPhillips Company in the U.S.and other countries.
-
8/10/2019 Oil Analysis guide and sampling procedure.pdf
8/28
6
The presence of water in engines
indicates contamination from outsidesources, from condensation ofmoisture in the atmosphere, or frominternal coolant leaks. Water is typicallyevaporated by engines at normaloperating temperatures. However,water may remain in the oil whenengine temperatures are too low forevaporation to occur. Other types of
equipment, when operated at sufficienttemperatures, also tend to evaporatecontaminating water.
Oil analysis offers an effectivemethod of recognizing water/coolantcontamination before a major problemoccurs. Infrared analysis is used todetermine water content in used oil.Results are reported in percentvolume. The Karl Fischer method isused to measure water in systems thatare sensitive to low moisture content.Karl Fischer results are reported inppm.
Water/CoolantContamination
Cause
Effect
Solution
Low operating temperatureDefective sealsNew oil contaminationCoolant leak Improper storageCracked head Weather/moisture
Product of combustionOil cooler leak
Engine failureHigh viscosityPoor lubricationCorrosionEngine overheatingAcid formationWeld spots
Reduced additive effectiveness
Tighten head boltsCheck head gaskets Inspect for cracked headInspect heat exchanger and
oil coolers Evaluate operating conditions
Evaluate equipment use vs. designAvoid intermittent useCheck for external water/moisture
sourcesChange oil filter
-
8/10/2019 Oil Analysis guide and sampling procedure.pdf
9/28
7
Fuel dilution of crankcase oil by
unburned fuel reduces lubricanteffectiveness. The thinning of thelubricant can lead to decreased lubefilm strength adding to the risk ofabnormal wear. Depending on certainvariables, when fuel dilution ofcrankcase oil exceeds 2.5 to 5%,corrective action should be taken.Fuel dilution is measured by gas
chromatography. The results arereported in percent volume.
Fuel Dilution
Cause
Effect
Solution
Incorrect air/fuel ratio Extended idling Stop-and-go driving Defective injectors Inoperative carburetor choke Incomplete combustion Incorrect timing
Metal-to-metal contactPoor lubrication; oil thinningIncreased overall wearPiston ring wear
Decreased additive effectivenessRisk of fire or explosionReduced fuel economyDecreased oil pressureReduced engine performanceHigh operating costShortened engine life
Check fuel lines, worn pistonrings, leaking injectors/seals,pumps
Analyze driving/operatingconditions
Check spark timingAvoid prolonged idlingChange oil and filter more
frequentlyEvaluate equipment and use
vs. designCheck fuel qualityRepair/replace worn parts
-
8/10/2019 Oil Analysis guide and sampling procedure.pdf
10/28
8
Solids represent a measurement of
all solid and solid-like constituents inthe lubricant. The makeup of solidsdepends on the system. In dieselengines, fuel soot is usually the majorconstituent measured. In non-dieselcomponents, wear debris and oiloxidation products are measured. Allsolid material is measured andreported as a percentage of sample
volume or weight.
Solids
Cause
Effect
Solution
Extended oil drain intervalEnvironmental debrisWear debrisOxidation by-productsFilter leaking or dirtyFuel soot
Shorter engine lifeFilter pluggingPoor lubrication Engine deposits
Sludge formation Accelerated wearDecreased oil flowLacquer build-up
Drain oil, flush systemEliminate source of environmental
debrisEvaluate equipment use vs. design Evaluate operating conditionsReduce oil drain intervalsChange filter
-
8/10/2019 Oil Analysis guide and sampling procedure.pdf
11/28
9
Fuel soot is composed of carbonand is always found in diesel engine oil.Laboratory testing is used todetermine the quantity of fuel soot inused oil samples. Stringent exhaustemission regulations have placedgreater emphasis on fuel soot levels.One of the most significant impacts ofreduced emissions is control ofparticulate emissions, which resulted in
greater soot levels in the crankcase.The fuel soot level is a good indicatorof engine combustion efficiency andshould be monitored on a regularbasis for possible maintenance action.
Fuel Soot
Cause
Effect
Solution
Improper air/fuel ratioImproper injector spray patternPoor quality fuel Incomplete combustionClogged air induction Defective injectors Improper equipment operation
Low compressionWorn piston/rings
Poor engine performance
Harmful deposits or sludge Increased wear Shortened oil life Lacquer formationClogged oil filters
Ensure fuel injectors are workingproperly
Change oil Evaluate oil drain intervals Check compressionAvoid excessive idlingCheck fuel quality
-
8/10/2019 Oil Analysis guide and sampling procedure.pdf
12/28
10
Lubricating oil in engines and other
components combines with availableoxygen under certain conditions toform harmful by-products. Heat,pressure, and catalyst materialsaccelerate the oxidation process. By-products of oxidation form lacquerdeposits, corrode metal parts, and
thicken oil beyond its ability tolubricate. Most lubricants contain
additives that inhibit or retard theoxidation process.
Differential infrared analysis offers theonly direct means of measuring thelevel of oxidation in oil. Note: A new oilreference is required for accuratemeasurement of oxidation. Results arereported on an absorbance scale.
Oxidation
Cause
Effect
SolutionHC + O2 =
OverheatingExtended oil drain intervalImproper oil type/inhibitor additivesCombustion by-products/blow-by
Shortened equipment life Lacquer depositsOil filter pluggingIncreased oil viscosityCorrosion of metal partsIncreased operating costs
Increased overall wearDecreased engine performance
Use oil with oxidation inhibitor
additivesShorten oil drain intervalsCheck operating temperatureEvaluate equipment use vs. design Evaluate operating conditions
-
8/10/2019 Oil Analysis guide and sampling procedure.pdf
13/28
11
Nitration products are formed
during the fuel combustion processwhen combustion by-products enterthe engine oil during normal operationor as a result of abnormal blow-bypast the compression rings. Theseproducts, which are more common inoils used to lubricate natural gas- andpropane- fueled engines, are highlyacidic, create deposits, and accelerate
oil oxidation. Infrared analysisrepresents the only method ofaccurately measuring nitration productsin oil. Results are reported on anabsorbance scale.
Nitration
Cause
Effect
Solution
NOx N2O
Improper crankcase scavengeLow operating temperatureDefective sealsImproper air/fuel ratioAbnormal blow-by
Increase operating temperatureCheck crankcase venting hoses and
valvesEnsure proper air/fuel mixturePerform compression check or
cylinder leak-down test
Accelerated oxidationNitrous oxides introduced into
environment Acidic by-products formedIncreased cylinder and valve train
wearOil thickening Combustion chamber deposits Increased acid no.
-
8/10/2019 Oil Analysis guide and sampling procedure.pdf
14/28
12
The total acid number is the quantity
of acid or acid-like constituents in thelubricant. An increase in TAN from thatof the new lubricant should bemonitored. The TAN of a new oil is notnecessarily zero since oil additives canbe acidic in nature. Increases in TANusually indicate lube oxidation orcontamination with water or an acidicproduct. TAN is an indicator of oil
serviceability.
Total Acid Number(TAN)
Cause
Effect
Solution
High-sulfur fuelOverheatingExcessive blow-byExtended oil drain interval Improper oil type
Corrosion of metallic componentsPromotes oxidationOil degradationOil thickening Additive depletion
Shorter oil drain intervals Verify correct oil type in serviceCheck for overheating
Check fuel quality
-
8/10/2019 Oil Analysis guide and sampling procedure.pdf
15/28
13
The total base number is an
expression of the amount of alkalineadditives in the lubricant that arecapable of neutralizing the acidproducts of combustion.
A new oil starts with the highestTBN it will possess. During the time
the lubricant is in service, the TBNdecreases as the alkaline additivesneutralize acids. TBN is an essential
element in the establishment of oildrain intervals since it indicateswhether the additives are still capableof providing sufficient engineprotection.
Most diesel engine manufacturersrequire the oil drained when its TBNreaches one-half or one-third itsoriginal value.
Cause
Effect
Solution
Total Base Number(TBN)
High-sulfur fuelOverheatingExtended oil drain interval Improper oil type
Increased acid no.Oil degradation Increased wearCorrosion of metal partsAcid build-up in oil
Use low-sulfur fuel Follow manufacturers
recommendations for oil draininterval, and decrease if engine is
operated under severe conditionsVerify TBN of new product/use
correct oil typeChange oil/top off with fresh oil Test fuel quality
-
8/10/2019 Oil Analysis guide and sampling procedure.pdf
16/28
14
Particle Count
Fluid cleanliness is critical in hydraulic
and other systems where high fluidpressure and velocity are involved.Excessive fluid particulatecontamination is a major cause offailure of hydraulic pumps, motors,valves, pressure regulators, and fluidcontrols. Failure due to excessiveparticulate contamination is normallysegregated into three areas:
Performance degradation Intermittent failureCatastrophic failure
Particle count measurements allowthe user to monitor hydraulic systemcontamination levels on a scheduled
basis. Scheduled analysis of hydraulicfluid to include particle count isrecommended by most equipment andhydraulic component manufacturers.
Cause
Effect
Solution
Water contaminationMachining burrsFilling techniquesOil oxidationContaminated new oil Worn wiper sealsSystem generated debris
Built in contamination Defective breather
Performance degradation
Intermittent failureWearPluggingLeakagePressure overshoot Momentary hesitationSystem failure
Filter new oil Change hydraulic fluid Inspect/replace filtersCheck particle sizesSystem flushing at high pressure
Check air breatherEvaluate equipment vs. design Evaluate operating conditionsEvaluate for proper service
techniques
-
8/10/2019 Oil Analysis guide and sampling procedure.pdf
17/28
15
30 5,000,000 10,000,000
29 2,500,000 5,000,000
28 1,300,000 2,500,000
27 640,000 1,300,000
26 320,000 640,00025 160,000 320,000
24 80,000 160,000
23 40,000 80,000
22 20,000 40,000
21 10,000 20,000
20 5,000 10,000
19 2,500 5,000
18 1,300 2,500
17 840 1,300
16 320 840
15 160 320
14 80 160
13 40 80
12 20 40
11 10 20
10 5 10
9 2.5 5
8 1.3 2.5
7 0.64 1.3
6 0.32 0.64
NUMBER OF PARTICLES PER ML
UP TO AND INCLUDING
NUMBER OF PARTICLES PER ML
GREATER THAN
RANGE
NUMBER
The ISO 4406:1999 Cleanliness Codereferences the number of particles greater than 4, 6, and
14 microns in each milliliter of fluid. A corresponding cleanliness code, such as 18/15/13, is then
given to the fluid. For particle concentration that fall between two adjacent particle concentration,
the higher range is used.
ISO 4406:1999 Particle Concentration
and Range Number
-
8/10/2019 Oil Analysis guide and sampling procedure.pdf
18/28
16
Wear Metals/Elemental Analysis
Elemental analysis is used to evaluate and quantify wear metal elements, additiveelements and contamination elements. Wear metals are analyzed to pinpointproblem areas through trend analysis. By analyzing the additive elements, the oil
type can be verified, i.e., hydraulic oil, transmission fluid, or engine oil.Contamination elements are reviewed to determine lubricant serviceability and topinpoint causes of problems indicated by other test results.
Following are the sources of the elements analyzed and their function in acomponent:
Element Source FunctionIron (Fe) Engine blocks, Gears, Rings,
Bearings, Cylinder Walls,Cylinder Heads, Rust
Because of its strength, iron is the base metal of steel inmany parts of the engine. Since iron will rust, it isalloyed with other metals (i.e., Cr, Al, Ni) making steel.
Chromium(Cr)
Shafts, Rings, ChromateFrom Cooling System
Because of its strength and hardness, Chromium is used to platerings and shafts that are usually mated with steel (softer).Chromium is also alloyed with iron (steel) for strength.
Aluminum
(Al)
Bushings, Some Bearings,
Pistons, Turbocharger,Compressor Wheels
Aluminum is a strong light-weight metal (smaller mass)
that dissipates heat well and aids in heat transfer.
Copper (Cu) Bearings, Bushings, OilCoolers, Radiators
Copper is utilized to wear first in order to protect othercomponents. Copper conforms well so it is used to seatbearings to the crankshaft.
Lead (Pb) Bearing Overlay, LeadedGasoline Contamination
Lead is a conforming material used to plate bearings.Lead will appear in new engines while the bearings aremelding and conforming. If lead appears later,misalignment may be indicated.
Nickel (Ni) Valve Stems, Valve Guides,Ring Inserts on Pistons
Nickel is alloyed with iron in high strength steel used tomake valve stems and guides.
Silver (Ag) Bearing Cages (anti-frictionbearings), Silver Solder,Turbocharger bearings andwrist pin bushings.
Silver is used to plate some components because itconforms well, dissipates heat and reduces coefficient offriction.
Tin (Sn) Bearings, Pistons Tin is a conforming material used to plate and protectsurfaces to facilitate break-in.
Molybdenum(Mo)
Piston rings, oiladditives
Molybdenum is used as an alloy in some piston rings in theplace of Chromium. Molybdenum is also used as a friction-reducing additive in some oils. Soluble Mo can be used asan antioxidant additive.
-
8/10/2019 Oil Analysis guide and sampling procedure.pdf
19/28
17
Element FunctionZinc (ZN) AW, EP, Antioxidant
Phosphorus(P)
AW, EP, AntioxidantPhosphorus is added to extreme pressure oils to provide a protective film. EP oilsare characterized by high phosphorus and sulfur levels.
Barium (Ba) DetergentBarium is toxic and expensive but it is advantageous because it does not leaveexcessive ash residue.
Alkaline (base) additives used to neutralize acids formed by products of combustionin engine oils. They also have some detergent qualities and corrosion inhibition.
InhibitorBoron is also found as an additive in coolant as borate.
Copper (Cu) AntioxidantCopper is added to engine oils to prevent oxidation.
Contaminant Elements
Element Cause
Sodium (Na) External Contamination, Coolant leak, salt in the air.
Silicon (Si) External (dirt), Additive, SealantsSilicon can be an antifoam additive and from gasket material in the formof silicone.
Potassium (K) Coolant leakPotassium is a coolant additive, and its presence in oil is indicative of coolantcontamination.
Sodium (Na),Calcium (Ca) andMagnesium (Mg)
Boron (B)
Additive Elements
TermsDetergent-Additive which keeps the engine clean at high operating temperature.Dispersant-Additivewhich keeps debris in suspension in the oil, controls depositsat moderate temperature.
Anti-wear (AW)-Additivewhich provides a protective film.Extreme Pressure (EP)-Additive which provides a protective film in high-pressureareas.
-
8/10/2019 Oil Analysis guide and sampling procedure.pdf
20/28
18
Infrared Analysis
Infrared Spectroscopy (IR or FTIR) is a technique that is very usefulfor: identifying oil and foreign-body contamination, identifying additive concentrationsor depletions, and identifying oil degradation reactions. The technique is based on
the principle that infrared light is absorbed in very specific ways by different
structures in organic molecules. Therefore, the IR instrument is capable of detectingand identifying specific molecule-structures even in a mixture as complicated as usedlubricating oil!
Although the actual science behind infrared Spectroscopy analysis is quitecomplicated (see above for typical FTIR output graph!), our lubricant customers canrely on their oil analysis reports to tell them all they need to know about thecondition of their oil. Therefore, using the IR method, along with appropriate
reference materials and target levels based on years of experience, the oil analystis able to provide easy-to-read summary comments on the oil condition in thefollowing areas: oil oxidation, oil nitration, water/antifreeze contamination, fueldilution, soot contamination, and oil cross-contamination.
-
8/10/2019 Oil Analysis guide and sampling procedure.pdf
21/28
19
Typical Paper Analysis Test Report
The success of your equipment oil analysis program is directly dependent on the
information provided on this report PLUS your use of the information. Reports canbe distributed to you by mail, personal computer or fax. Understanding and usingthe information provided on the test report is the key to an effective oil analysis testprogram.
Below is an example of the type of information provided in the typical analysistest report.
-
8/10/2019 Oil Analysis guide and sampling procedure.pdf
22/28
20
Comments. The laboratory makes acomment on every sample processed. Commentsare made in easily understood, concise, laymansterms. Comments include:a. A diagnosis of machine condition based
on oil analysis.b. Corrective maintenance recommendations
when necessary.c. Subsequent oil sample interval recom-
mendations. For example: Resample at
scheduled interval, resample at one-halfscheduled interval, resample as soon aspossible. Maintenance feedback of the resultsof lab recommendations is also listed in theComments section.
Oil Analysis Data. This table containsthe results of up to 6 consecutive oil samples forcomparison
Physical Data. Changes in the physicalqualities of the lubricant are determined and
evaluated. These changes and the presence ofcontaminants affecting the properties of lubricantshave a direct bearing on its serviceability. Problemswith the physical properties may affect the valuesdetected in the Elemental Concentrations.
Elemental Concentrations. Theseare measurements in Parts Per Million (PPM) of the
major elements studied to determine equipmentserviceability. Those elements consist of three maingroups: Wear Metals, Contaminants and Additives.Conditions above normal are coded B, C, D basedon severity.
DO NOT HOLD SAMPLES. MAIL SAMPLES
THE SAME DAY THEY ARE TAKEN.
Sample Information. This is
background information provided by the customeron each sample submitted for analysis. SampleDate indicates the date the oil sample wasextracted from the machine. HOURS ON OIL isthe number of service miles or hours accumulatedon the lubricating oil.
Unit Information. This section lists the
identification or serial number of the unit sampled.The name of the company that owns/operates theunit and the units geographic location areprovided. The equipment manufacturer, model, oilcapacity and oil type are also listed here. Unitinformation is supplied by the customer.
Typical Paper Analysis Test Report (continued)
-
8/10/2019 Oil Analysis guide and sampling procedure.pdf
23/28
21
Quality EquipmentOil Analysis Program
Machine Type
Diesel enginesGasoline enginesTransmissionsGears, Differentials,Final drivesHydraulics
Recommended Sampling
Frequency150 hours, 10,000 miles3,000 to 5,000 miles300 hours, 20,000 miles300 hours, 20,000 miles
300 hours, 20,000 miles
Aviation Reciprocating enginesTurbinesGearboxesHydraulics
25-50 hours100 hours100-200 hours100-200 hours
Industrial &Marine
Manufacturing, Processing,Power generation, Natural gasdistribution, Oil & gasexploration, Marine equipment
Diesel enginesNatural gas engines
Gas turbinesSteam turbinesAir, gas compressorsRefrigeration compressorsGears, bearingsHydraulics
Normal useMonthly, 500 hoursMonthly, 500 hours
Monthly, 500 hoursBi-monthlyMonthly, 500 hoursBeginning, Midpoint & end of seasonBi-monthlyBi-monthly
Intermittent useQuarterlyQuarterly
QuarterlyQuarterlyQuarterly
QuarterlyQuarterly
Industry
Off Highway &GroundTransportation
Mining, Construction,Agriculture, Buslines,Railroads, Forestry,Automobiles
Oil Analysis Via the Internet
AnalysisPlus Support
Basic Testing: Lab One 866-652-2663
Premium Testing: POLARIS Laboratories 866-341-4396
Staveley Services 877-645-5221
Note: General recommendation consult OEM and lubricant manufacturer for specific recommendations.
-
8/10/2019 Oil Analysis guide and sampling procedure.pdf
24/28
22
To properly evaluate machine
conditions, the oil samples submittedfor analysis must be representative ofthe system from which they are taken.For best results, follow theseguidelines:1. The machine being sampled should
be brought to normal operatingtemperature. Oil should berecirculated, if appropriate. This will
ensure that insoluable andsemisoluable contaminants areuniformly dispersed throughout thesystem. Samples taken frommachines that have been inactive forlong periods are not representative.
2. Oil samples should always be takenin the same manner and from thesame sampling point.
3. Do not sample a machineimmediately after an oil change orafter a large amount of make-up oilhas been added.
4. Use a clean dry container to drawthe oil sample. Ship samples in theplastic bottles provided in thepackage. Hydraulic fluids or other
oils submitted for a particle countanalysis should be submitted in thesuper clean bottles providedwhen special testing is requested.
Sample Gun MethodThe oil test package includes a
plastic sampling bottle used forcollecting and shipping samples. A
special inexpensive sampling gun is alsooffered as an option, together withconvenient lengths of plastic sampling
Oil Sampling Procedures
tubing. The plastic sampling bottle fits
directly into the sampling gun, and theoil sample can be drawn directly fromthe machine into the sampling bottle.The sampling gun allows the user todraw representative samples quicklyand with a minimum of effort.Procedures are as follows:
1. Measure a sufficient length of plasticsampling tubing to reach from the
sampling gun through the sampleaperture and into the machine sumpor reservoir. If the machine has adipstick, the tubing should bemeasured against the dipstick toestablish the proper sampling depth.
2. Loosen the nut on the sample gunhead, insert the free end of thesampling tubing through the nut(about 1/2 inch past nut) and tighten
the nut to compress the sealing ringto obtain a vacuum-tight seal. Screwa clean plastic sampling bottle into
the gun adaptor.3. Holding the sampling gun upright,
draw oil into the bottle using thepiston lever until oil is within 1/2 inch
of the top. To stop the oil flow,break the vacuum by partiallyunscrewing the bottle. Remove thebottle from the adaptor, screw thecap on tightly and wipe the bottleclean. Fill out the unit or machineidentification number on the bottlelabel.
4. Replace the plastic tubing after each
sampling to avoid sample cross-contamination.
-
8/10/2019 Oil Analysis guide and sampling procedure.pdf
25/28
23
Sample Valve/Petcock
MethodCare should be taken to install thevalve on the lube system in a location
that will ensure representative oilsamples can be drawn. The exterior of
the valve should be wiped clean priorto sampling to ensure that no externalcontamination finds its way into the oil.Stagnant oil should be drained from
the valve by drawing a small oil sampleinto a waste oil container just prior tocollecting the oil sample in the plasticsampling bottle. Screw the bottle capon tightly and wipe the bottle clean. Fillout the unit or machine identificationnumber on the bottle label.
Oil Drain MethodClean the area around the drainplug thoroughly to avoid samplecontamination. Allow some of the oil
to drain into a waste oil containerprior to collecting the oil sample. Placea clean dry sample bottle into the oilstream and fill it to within 1/2 inch of the
top. Screw the cap on tightly and wipe
the bottle clean. Fill out the unit ormachine identification number on thelabel.
NOTE:When taking oil samplesfrom hydraulic systems for particlecount analysis, special care must be
taken to assure the samples arerepresentative and that they arecontamination free. Use the specialsuper clean bottles to sample oils forparticle count analysis.
-
8/10/2019 Oil Analysis guide and sampling procedure.pdf
26/28
24
www.AnalysisPlus.net
866-341-4396
877-645-5221
866-652-2663
Lab One Inc
QUALITY
OIL
ANALYSIS
SINCE
1985
Premium Oil Analysis
Basic Oil Analysis
-
8/10/2019 Oil Analysis guide and sampling procedure.pdf
27/28
-
8/10/2019 Oil Analysis guide and sampling procedure.pdf
28/28
Get the information you need to make better decisions and reduce your maintenance costs.Sign up for the ConocoPhillips AnalysisPlus Oil Analysis Program today.
Signing up is easy:Join through Lubestreamor visit www.analysisplus.net
Copyright2007 ConocoPhillips Company. The ConocoPhillips logo, Conoco, the Conoco Logo, Phillips 66, thePhillips 66 logo, 76 and the 76 logo are trademarks of ConocoPhillips Company in the U.S.A. and other countries.
Questions? Your ConocoPhillips Marketing Rephas the answers. Make the switch to AnalysisPlus
today and take control of your oil testing system.