oceanstor t series configuration and quotation guide - huawei · page 5 introduction to file...

26
Security Level: OceanStor T Series Configuration and Quotation Guide

Upload: buixuyen

Post on 13-May-2018

230 views

Category:

Documents


3 download

TRANSCRIPT

Security Level:

OceanStor T Series

Configuration and Quotation

Guide

Contents

3

Configuration Instructions 2

Product Overview 1

Configuration Instances

Page 3

Overview of the T Series V001R005

Unified storage

File engine

Block-level storage

S2200

T

S6800T

Page 4

Introduction to the T Series V001R005 Unified Storage Products

Model S2600T S5500T S5600T S5800T

Data Block Storage Components

Processor Multi-core processors

Cache size 8 GB/16 GB 8 GB/16 GB/32 GB 24 GB/48 GB 96GB/192GB

Front-end host port

8 Gbit/s Fibre Channel, 1

Gbit/s Base-T iSCSI, 10 GE

iSCSI (TOE)

8 Gbit/s Fibre Channel, 1 Gbit/s Base-T

iSCSI, 10 GE iSCSI (TOE), 10 Gbit/s

FCoE

8 Gbit/s Fibre Channel, 1 Gbit/s Base-T

iSCSI, 10 GE iSCSI (TOE), 10 Gbit/s

FCoE

8 Gbit/s Fibre Channel, 1 Gbit/s Base-T

iSCSI, 10 GE iSCSI (TOE), 10 Gbit/s

FCoE

Back-end expansion port 6 Gbit/s SAS 2.0 wide 6 Gbit/s SAS 2.0 wide 4 Gbit/s Fibre Channel or 6 Gbit/s SAS

2.0 wide

4 Gbit/s Fibre Channel or 6 Gbit/s SAS 2.0

wide

Number of onboard I/O ports

Front-end: 12 x 1 Gbit/s

iSCSI;

Back-end: 4 x SAS 2.0 wide

Front-end: 8 x 8 Gbit/s Fibre Channel;

Back-end: 4 x SAS 2.0 wide 0 0

Max. number of I/O modules 2 2 10 12

Max. number of disk slots 276 528 1152 1440

Supported disk type SAS, NL-SAS, SATA, SSD SAS, NL-SAS, SATA, SSD Fibre Channel, SAS, NL-SAS, SATA,

SSD Fibre Channel, SAS, NL-SAS, SATA, SSD

Supported RAID level RAID 0, 1, 3, 5, 6, 10, 50

Value-added functional software

HyperImage (virtual snapshot), HyperCopy (LUN copy), HyperClone (split mirror), HyperMirror (synchronous/asynchronous remote replication), HyperThin (thin

provisioning), Application Protection Manager (application-level data protection), UltraPath (multipathing), DiskGuard (host-side data protection), SmartCache

(dynamic data caching for the TurboBoost)

File Storage Components

Supported number of file engine

nodes 2 2 and 4 2, 4, 6

2, 4, 6, 8

Processor Multi-core processors

Cache size per node 16 GB 16 GB 24 GB 24 GB

Max. number of I/O modules per

node 6 6 6 6

File system software Dynamic storage tiering, virtual snapshot, mirroring, remote replication, Symantec NetBackup Client

Supported network protocol Fibre Channel, SAS, iSCSI, NFS, CIFS, FTP, HTTP

Max. size of a single file system 256 TB with dynamic expansion supported

Supported operating system AIX, HP-UX, Solaris, Linux, Windows

Virtualization Features

Support for VMware VAAI Supports VMware VAAI interfaces, significantly improving storage performance and efficiency under virtual environments.

Support for the integration with

vSphere and vCenter

Integrates vRecovery for vSphere and vSphere vCenter, implementing virtual-machine-granularity backup, replication, and disaster-tolerance switch, and

supporting disaster recovery drills.

Page 5

Introduction to File Engines

Interface module

• Each node has six I/O module slots.

• Each node has a GE card for heartbeat

signaling.

• Each node has an 8 Gbit/s Fibre Channel card

for disk array connection.

• Each node has a maximum of four GE or

10GE cards for interfacing with NAS hosts.

• Being based on the Pangea V001R001

hardware platform (namely the controller

enclosure of an S5500T/S5600T/S6800T),

the file engine of a T series unified storage

system is also 4 U high.

• Each controller in this independent engine

serves as a file engine node, and each

engine serves as a two-node file engine.

Controller-file engine

• Each controller serves

as a node.

Page 6

Internal Heartbeat Network

of a File Engine

Heartbeat network of a multi-node file engine

(It requires additional switches, and each node uses two GE ports as heartbeat network ports.)

Heartbeat network of a two-node file engine

Note: the GE I/O Module comes with File engine can only be used for heartbeat. The host connectivity requires extra I/O Module

Page 7

Introduction to S5500T Storage

Controllers (Part 1) 2.5-inch controller enclosure

• Supports 24x2.5-inch disks.

• Supports mainstream SAS and NL-SAS disks as well as SSDs.

• Houses four 2+2 redundant coffer disks in the first four slots.

• Supports the independent power-on or power-off of each disk.

Power module

• Adopts 1+1 redundancy.

• Offers a power conversion efficiency up to 92%, which is higher

than the 88% of conversion efficiency for golden power supplies.

Fan/BBU module

• Adopts 3+1 redundancy for fan modules, ensuring system

continuity when a single fan module becomes faulty.

• Supports delicate and intelligent fan speed control.

• Embeds BBUs against the data loss caused by expected power

failures.

Control unit in the disk and controller integration configuration

• Provides management network ports and serial ports.

• Carries two onboard 4x6 Gbit/s SAS ports.

• Supports one expansion I/O module.

• Carries four onboard 8 Gbit/s Fibre Channel ports.

3.5-inch controller enclosure

• Supports 12x3.5-inch disks.

• Supports mainstream SAS and NL-SAS disks as well as SSDs.

• Houses four 2+2 redundant coffer disks in the first four slots.

• Supports the independent power-on or power-off of each disk.

Page 8

Introduction to S5600T/S5800T Storage

Controllers (Part 1) Control module

• Uses two controllers.

• Supports intelligent CPU

frequency control for

energy saving.

• Provides a system power-

off button.

BBU module

• Adopts 2+2 redundancy.

• Supports the power failure protection

for DC/AC power supplies.

Power module

• Uses dual power planes with 2+2

redundancy.

• Offers a power conversion efficiency

of 92%, which is higher than the 88%

of conversion efficiency for golden

power supplies.

Fan module

• Adopts 5+1 redundancy for fan

modules, ensuring system continuity

when a single fan module becomes

faulty.

• Supports delicate and intelligent fan

speed control.

Interface module

• Offers 12 I/O module slots.

• Supports a maximum of

1440 disks.

• Supports the hot swap for

I/O modules.

• Supports various ports

including 8 Gbit/s Fibre

Channel, 4 Gbit/s Fibre

Channel, 4x6 Gbit/s SAS,

and GE/10GE ports.

Management module

• Adopts 1+1 redundancy.

• Supports hot swap.

Page 9

Connecting a File Engine to a Storage

System Through Fibre Channel Ports

引擎节点2

Storage unit

Engine node 1

Engine node 3

Engine node 5

Engine node 7

Engine node 2

Engine node 4

Engine node 6

Engine node 8

Controller BController A Each file engine node connects

controllers A and B through two

Fibre Channel ports.

Page 10

• For theS2600T S5500T:

24-slot, 2.5-inch, 2 U SAS disk enclosure

24-slot, 3.5-inch, 4 U SAS disk enclosure

(Does not support 4 U Fibre Channel disk

enclosures.)

• For the S5600T/S5800T/S6800T:

24-slot, 2.5-inch, 2 U SAS disk enclosure

24-slot, 3.5-inch, 4 U SAS disk enclosure

24-slot, 3.5-inch, Fibre Channel disk enclosure

Disk enclosure

4 U, 24 slots for 3.5-inch SAS disks

2 U, 24 slots for 2.5-inch SAS disks

4 U, 24 slots for 3.5-inch Fibre Channel disks

Introduction to the T Series Storage

Disk Enclosures

Page 11

ISM Functions

Required storage system management software

Integrated Storage Manager-Device Management License

for OceanStor Unified XXX (for unified storage systems)

Integrated Storage Manager-Device Management License

for OceanStor Block XXX to Unified XXX Upgrade (for

upgrading disk arrays to unified storage systems)

Integrated Storage Manager-Device Management License

for OceanStor Block XXX (for disk arrays)

File Engine Software Functions File Engine CIFS (autoconfigured for common Internet file

systems) File Engine NFS (autoconfigured for network file systems) File Engine FTP File Engine Replication File Engine Dynamic Storage Tiering

Disk Array Software Functions

HyperImage (virtual snapshot)

HyperCopy (LUN copy)

HyperMirror (synchronous/asynchronous remote replication)

HyperThin (thin provisioning)

SmartCache (dynamic data caching controlled by on-

demand configured license)

UltraPath Functions

Required multipathing software (autoconfigured and support

for all the mainstream operating systems)

DiskGuard Functions Host-side data protection software controlled by on-demand

configured license

Value-added Software Functions

ISM — centralized graphical

management software

• Easily monitors the operating status of various system

components such as power modules, fan modules,

disks, and host ports on a single interface.

• Presents useful installation wizards and five-minute

initial configuration for simplified storage management.

Contents

3

Configuration Instructions 2

Product Overview 1

Configuration Instances

Page 13

Quotation Elements for the T Series

V001R005

集群NAS引擎

服 务

其组件

存储单元

Storage file engine

Controller enclosure

Disk enclosure

Disk unit

Value-added storage functional component

File engine

Controller

enclosure

Storage unit

Value-added

function

Page 14

Unified Storage Product Configuration Procedure Start the

UniSTAR tool.

Determine the number

of file engine nodes.

Select a controller

enclosure. Select a type of

power supplies.

Select front-end

expansion I/O modules.

Determine the type

& number of disks.

Select installation materials

& auxiliary devices.

Select value-added

functions.

Determine the

cache size.

Select a type of

power supplies.

Select front-end

expansion I/O modules.

Determine the

cache size.

Select back-end

expansion I/O modules.

Determine the type

& number of disks.

Select installation materials

& auxiliary devices.

Select value-added

functions.

S5600T/S5800T

Basic

config

.

S2600T/S5500T

Determine the type

& number of disks.

Select Fibre

Channel modems.

Select value-added

functions.

Determine storage

system specs.

Typical config.

Notes: Each file engine node natively has four GE ports and four Fibre Channel ports including two

GE ports for heartbeat signaling and two Fibre Channel ports for connecting to disk arrays.

A file engine with more than two nodes requires two 24-port Ethernet switches.

For the S5600T/S5800T in the basic configuration, you must select a type (SAS or Fibre

Channel) of back-end I/O modules for it.

Select file engine

I/O modules.

Select a model of

storage product.

(optional)

Select a model from the S2600T, S5500T, S5600T, and S5800T.

Select a

file engine.

Page 15

S6800T Storage Configuration

Procedure

Start the UniSTAR tool.

选择安装维

保服务

Select accompanying

value-added software.

Select disks &

installation materials.

Select a controller

enclosure.

Select a type of

controller enclosure. Select a type of

power supplies.

Select front-end

expansion I/O modules. Select disks.

Select installation materials

& auxiliary devices. Select modems.

Note:

Configuring and quoting the S6800T excludes selecting file

engines as it is a non-unified storage product.

Select back-end

expansion I/O modules.

(optional)

Select value-added functions.

Page 16

Software and Value-added Function Quotation Description

File

Integrated Storage Manager-Device Management License for OceanStor Unified XXX

Unified storage software: autoselected (Block storage management software is unnecessary for unified storage.)

Integrated Storage Manager-Device Management License for OceanStor Block XXX to Unified XXX Upgrade

Unified storage software (for upgrading from disk arrays to unified storage systems): manually selected

File Engine CIFS File Engine NFS File Engine FTP File Engine Replication File Engine Dynamic Storage Tiering

File engine software: 1. Autoconfigured when either of the items in

green is selected 2. Manually configured when any of the other

three items is selected

Data

Blo

ck

Integrated Storage Manager-Device Management License for OceanStor Block XXX

Disk array configuration functions: autoselected

HyperImage (virtual snapshot) HyperCopy (LUN copy) HyperMirror/S (synchronous remote replication) HyperMirror/A (asynchronous remote replication) HyperThin (thin provisioning)

Optional value-added functions

SmartCache At least four SSDs are recommended.

OceanStor UltraPath Multipathing software: For the typical configuration: autoconfigured; For the basic configuration: autoconfigured

OceanStor DiskGuard (V100R002) Optional host software

Quotation Instructions on Product Software and

Value-added Functions

Page 17

Installation Materials and Auxiliary Devices Installation Material Quotation Description

Patchcord, DLC/PC-DLC/PC, multi-mode, 62.5/125, 2 mm, 3 m Autoconfigured according to the

number of host optical ports;

Support for additional cables for a

higher configuration Patchcord, DLC/PC-DLC/PC, multi-mode, 2 mm,10 m

Purchased cable, mini SAS, 28 AWG, Key246, 1 m

Autoconfigured according to the

number of disk enclosures;

Support for additional cables for a

higher configuration

Purchased cable, mini SAS, 28 AWG, Key246, 3 m

Purchased cable, external mini SAS, 6.0 m, external mini SAS 26-pin plug, 24 AWG x 8P, external

mini SAS 26-pin plug

Auxiliary Device Quotation Description

Modem, 56 Kbit/s, data/fax, external, one-to-two (DB25 to DB25/DB9) cable, AC-to-12 V AC

adapter, English documentation Optional depending on whether or not

remote maintenance is required Modem, wireless GPRS, 48 Kbit/s, wireless interface, external, 100 to 240 V AC-to-12 V DC

adapter, 5.5 mm x 2.1 mm adapter connector, English documentation, RS232 standard serial port

Optical transceiver:

▬ Autoconfigured according to the number of host optical ports

Disk unit filler panel:

▬ Unquoted item

▬ Default configuration for vacant slots

I/O module filler panel:

▬ Unquoted item

▬ Default configuration for vacant slots

Page 18

1. Choose an appropriate RAID level.

▬ Chooses a suitable RAID level from the supported RAID 0, 1, 5, 6, 10, and 50 based on the actual

application scenario.

▬ As recommended, uses RAID 5 or 1 SAS or Fibre Channel disks

▬ You need to use RAID 6 for a RAID group that consists of NL-SAS disks or SATA disks. (The ISM

uses RAID 6 by default) .

2. Configure a moderate number of disks for each RAID group.

▬ The optimal number of disks configured for one RAID 5 or RAID 6 group is 8 to 11.

▬ Configures a maximum of 16 disks for each RAID 10 group.

▬ Weighs the disk utilization ratio, disk failure rate, reconstruction duration, and disk performance when

you choose a RAID level.

3. Deploy hot spare disks.

▬ Deploys hot spare disks whenever possible.

▬ Avoids using coffer disks as hot spare disks.

▬ As recommended, configures at least one hot spare disk for each enclosure and at least two for the

sole controller enclosure.

4. Intermix different types of disks in practice.

▬ Avoids intermixing high-speed disks with low-speed ones within the same enclosure.

▬ Configures dedicated hot spare disks for different types of disks.

5. Calculates the available capacity of disks according to the RAID level (redacted).

6. Configures an ideal of no more than 72 and a maximum of less than 120 disks for each pair of back-end

ports.

Configuration Notes

Page 19

Contents

3

Configuration Instructions 2

Product Overview 1

Configuration Instances

Page 20

Unified Storage Product

Configuration Instance Customer requirements:

• Uses the S5600T with a cache capacity no less than 48 GB and supports AC

power supplies.

• Requires FC SAN, NFS, and CIFS protocols for the unified storage device and

needs a two-node file engine.

• Requires four GE ports as file engine ports.

• Requires 6 TB of raw capacity sourced by 3.5-inch, 600 GB, 15,000 rpm, SAS

disks for their database applications.

• Requires 200 TB of raw capacity sourced by 3.5-inch, 2 TB, 7200 rpm, NL-SAS

disks for their file applications.

• Requires 8x8 Gbit/s Fibre Channel and 16xGE iSCSI ports as front-end ports.

• Supports virtual snapshot and cloning software.

• Supports thin provisioning.

• Supports dynamic storage tiering for file engines.

Page 21

Unified Storage Product Configuration Instance (Continued) Step 1 Choose a storage product and configure the file engine, controller

enclosure, and interface modules for it.

Note: Each NAS engine node has four native GE

ports with two for heartbeat signaling. Configure a

pair of GE I/O module for host NAS connectivity

Select whether or not to use a file engine for

unified storage.

Select a number of file engine nodes.

Select either the basic or typical configuration

for the controller enclosure.

Select a type of power supplies.

Select a specification of controller enclosure.

Select a type and number of ports for the

controller enclosure.

Select either SAS or Fibre Channel as the type

of back-end expansion disk enclosures.

Page 22

Unified Storage Product Configuration Instance (Continued)

Step 2 Select a type and number of disks and choose value-added software functions.

Select a type and number of disks.

Select required value-added functions (in

the red circle) for data blocks.

Select required value-added functions (in

the green circle) for file systems.

Page 23

S6800T Configuration Instance

Customer requirements:

• Uses the S6800T with a cache capacity no less than 192 GB and

supports AC power supplies.

• Requires 2 TB of SSD cache sourced by 3.5-inch, 200 GB of SSDs.

• Requires 30 TB of raw capacity sourced by 3.5-inch, 600 GB,

15,000 rpm, SAS disks for their database applications.

• Requires 200 TB of raw capacity sourced by 3.5-inch, 2 TB, 7200

rpm, NL-SAS disks for their file applications.

• Requires 16x8 Gbit/s Fibre Channel and 16xGE iSCSI ports as

front-end ports.

• Supports SSD caching.

• Supports virtual snapshot and cloning software.

• Support asynchronous remote replication.

• Supports thin provisioning.

Page 24

S6800T Configuration Instance (Continued) Step 1 Choose a storage product and select controller enclosure, interface module,

and power supply types.

Select a type of power supplies for the

controller enclosure.

Select a specification of controller enclosure.

Select front-end I/O modules.

Select I/O modules for the required type of

back-end disk enclosures.

Note: SAS I/O modules are selected in this case

as the customer needs SAS disks for their back-

end disk enclosures.

Select a type and number of disks.

Note: SSDs are selected in this case as the

customer needs the SmartCache function.

Page 25

S6800T Configuration Instance (Continued)

Select required value-added storage

functions.

Copyright©2012 Huawei Technologies Co., Ltd. All Rights Reserved. The information in this document may contain predictive statements including, without limitation, statements regarding the future financial and operating results, future product portfolio, new technology, etc. There are a number of factors that could cause actual results and developments to differ materially from those expressed or implied in the predictive statements. Therefore, such information is provided for reference purpose only and constitutes neither an offer nor an acceptance. Huawei may change the information at any time without notice.

HUAWEI ENTERPRISE ICT SOLUTIONS A BETTER WAY