nuclear, safety and protection catalogue_english 2012
DESCRIPTION
Air filtration solutions for nuclear industrySupport and technicalassistance in the fi eldOur team of engineers and qualifi ed tech-nicians is at your service for:Your new installations:• Assistance for assembling equipment (Tight lock casings, SOFILTRAD iodine traps, etc.).• Assistance for the installation of fi ltra-tion items (carbon loading, implemen-ting fi ltering cells, etc.).Maintenance:• Equipment diagnostics.TRANSCRIPT
Camfil Farr77 / 81 boulevard de la République
FR - 92257 La Garenne Colombes CedexTel. + 33 (0) 1 46 52 48 00Fax + 33 (0) 1 47 60 17 81
20
10
- ju
in
www.camfilfarr.com
The Camil Farr group standards’…
...Camfil Farr is the global leader in clean air technology and energy efficient air filter solutions with product development, R&D and local representation in America, Europe and in the Asia-Pacific region.
We supply high-quality products and services with the aim of making our customers operations more sustainable, energy efficient and productive.
Our own vision of sustainability is a global approach combining consideration for people, environmental protection and business performance.
Camil Farr is a member of the United Nations Global Compact program and follows the GRI (Global Reporting Initiative) sustainability reporting framework.
Cam
fil F
arr
201
2-01
Camfi l Farr Products and Services
Air fi ltration solutions for nuclear industry
Camfi l Farr - clean air solutions
Cam
fil Farr - Safety and P
rotection Catalogue
Safety and Protection
Dear Customers,
The entire Protection and Safety team is delighted to introduce you our new Camfi l Farr edition 2012 catalogue.
Our experience feedback, the analysis of your needs and the increasingly demanding technical requirements (earthquake, leak-tightness, specifi c particles and molecules) allowed us to develop this catalogue which aim is to bring you the best solutions related to the constraints of the nuclear industry.
We aim to be recognized as the fi rst clean air solutions’ supplier, as part as our sustainable development and by respecting our core values:
The COMMITMENT of our teams, which means we listen to you and provide advice, competency and a quick, high-quality response that meets your expectations.
The DURABILITY of being a family group of over 3400 people in the world, based on nearly 50 years of honest relations serving you and meeting your requirements. Tomorrow, we will still be here to bring you even more services.
TEAM WORK meaning quick responses to meet your needs in an irreproachable way guaranteeing that our commitments are upheld. We continue to learn and share our ideas and knowledge with you. There is only quality in each person.
CUSTOMER SATISFACTION, this is our only aim in our daily work: discovering your expectations and bringing you the solutions that meet most your needs. You are the key focus of our development.
LOCAL PRESENCE, we can ensure a local presence thanks to our 23 factories, our 4 a high-performance R&D centres, our 25 subsidiaries and distributors in over 50 countries.
These values are based on:• our skills in constantly developing new products to guarantee our fi lters and equipment
according to the most demanding specifi cations and standards CTHEN, NFX 44011, NFM 62200…
• the reliability of our promises regarding the effi ciency of our products, the very short delivery deadlines and the quality and the traceability of our products thanks to our ISO 9001 certifi cation.
• services related to our fi ltration fl eet managment and stock safety, to our “Camfi l School” training centre, to our specifi c offers of fi eld technical assistance and maintenance services for the installed equipment, etc.
Camfi l is involved in the respect of the environment through its ISO 14001 and EN 16001 certifi cations.
Do not hesitate to contact our fi ltration experts or to consult our website www.camfi lfarr.fr, for more information. Camfi l is at your service!
Thanks for the trust you give us every day. Looking forward to hearing from you! Happy reading!
Arnaud PAQUEGeneral Director
Saint Martin Longueau (Oise) factory 20,000 m².The biggest fi lter manufacturing site in Franceat your service.
Laboratory: chemical test
Sheet metal workshop: welding, assembly
Filter workshop: pleating
Technical department
Carbon workshop: carbon bench
You can find us on the Internet:
www.camfilfarr.com
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com 1
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
Intr
oduc
tion
Med
ium
Effi
cien
cyH
igh
Effi c
ienc
yVe
ry H
igh
Effi c
ienc
yAd
sorp
tion
Casi
ngs
and
fi lte
rsfo
r co
ntai
nmen
t sys
tem
sCo
ntai
nmen
t equ
ipm
ent
Equi
pmen
t for
tem
pora
ry v
entil
atio
nAc
cess
orie
s
Protection and Safety
GENERAL SUMMARY
Introduction p. 2
• THE CAMFIL FARR GROUP
• CAMFIL FARR AT YOUR SERVICE
• HISTORY
• QUALITY – SAFETY – ENVIRONMENT – ENERGY
• CAMFIL FARR SOLUTIONS IN THE NUCLEAR INDUSTRY
• THE UNIQUE SPECIFICATIONS OF OUR EQUIPMENT
Medium Efficiency p. 11
• CMJ VK100
• PLEATED GLASS FIBER FILTER
• CAMMETAL
• TM CHOC 2-IN-1
• SPARK ARRESTING FILTERS
High Efficiency p. 17
• OPAKAIR HT120
• POLY V-PACK CELLS 95% DOP
Very-High Efficiency p. 21
• GENERAL POINTS
• DELTAFIL
• POLY V-PACK FILTERS
• PTFE POLY V-PACK FILTERS
• CTHEN VALIDATED SOFILAIR FILTERS
• SETTLING TANK CANISTERS
Adsorption p. 31
• GENERAL POINTS
• CAPTURING HYDROGEN FLUORIDE
• CAPTURING RADIOISOTOPES
• ACTICARB 4000
• ACTIVATED CARBON V-PACKS
• REINFORCED BARRELS OF ACTIVATED CARBON FOR TRAPPING RADIOISOTOPES
• ACTICARB FOR TOXIC GASES
• MOLECULAR FILTRATION QUESTIONNAIRE
Casings and filters forcontainment systems p. 41
• GENERAL POINTS
• VHE CASING PVC 5 m3/h FILTERS
• VHE CASING PVC 20-30-50 m3/h FILTERS
• VHE CASING PVC 30 m3/h and 50 m3/h FILTERS
• VHE CASING METAL 30-70 m3/h FILTERS
• VHE CASING METAL 300 m3/h FILTERS
• 50 m3/h REMOTE HANDLING AND RECHARGEABLE VHE FILTERS
• ACTIVATED CARBON FILTERS
• SCHEMATIC DIAGRAM OF A STAINLESS STEEL CASING FOR VHE OR ACTIVATED CARBON FILTERS
• STAINLESS STEEL CASINGS 5 m3/h for 3205.11.00 fi lters
• STAINLESS STEEL CASINGS 30 m³/h
• STAINLESS STEEL CASINGS 70 m³/h
• STAINLESS STEEL CASINGS 300 m³/h
• FILTERS AND PUSH-PUSH SYSTEMS
• FILTERS FOR TIGHTNESS ENCLOSURES
• CASINGS FOR RADIOACTIVE CELLS
• BSS DUCT CASINGS
Containment equipment p. 61
• GENERAL REMARKS
• TIGHT LOCK CASINGS UNIT TYPE BUTTERFLY VALVES
• MULTICELL TYPE TIGHT LOCK CASINGS
• MULTICELL TYPE TIGHT LOCK CASINGS CONNECTING FLANGES
• ISOLATION DAMPERS
• SPECIFIC SURFACE TREATMENT FOR TIGHT LOCK CASING AND ISOLATION DAMPER
• OPERATING INSTRUCTIONS FOR FILTER CHANGE-OUT
• BAG OUT PORT TYPE PLATFORMS
• CRADLE PLATFORMS
• CAM PLATFORMS
• CAGES
• GAS ADSORBERS (SOFILTRAD model)
Equipment fortemporary ventilation p. 83
• MOBILE FAN FILTER CASINGS FOR NUCLEAR DISMANTLINGE
Accessories p. 87
• ACCESSORIES
• FILTRATION MEDIA Discs and Reels
• MEMORY JOGGERS
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com2
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
IntroductionM
edium Effi ciency
High Effi ciency
Very High Effi ciency
AdsorptionCasings and fi lters
for containment system
sContainm
ent equipment
Equipment for
temporary ventilation
Accessoires
The Camfil Farr Group…
Quick presentation of Camfi l Farr
Camfil Farr around the world
NUMBER OF EMPLOYEES: 526
SALES IN SEK MILLIONS: 319
ASIA-PACIFIC
NUMBER OF EMPLOYEES: 218
SALES IN SEK MILLIONS: 770
OTHER MARKETS
HEADQUARTERS PRODUCTION UNIT, INCL. SALES SALES OFFICE AGENT NUMBER OF EMPLOYEES: 1,560
SALES IN SEK MILLIONS: 2,345
EUROPE
NUMBERS OF EMPLOYEES: 864
SALES IN SEK MILLIONS: 1,046
AMERICAS
Our assets• About 50 years’ experience in the nuclear industry
• Complete range of air fi lters – One single supplier to meet all your needs
• Very-High Effi ciency (VHE) fi lters certifi ed for the nuclear industry by specifi c tests
• Internal development of applications to measure particles and radioactivity
• Camfi l Farr production sites strategically located close to nuclear power stations
• 92 nuclear power stations in the world fi tted with Camfi l Farr material
• Welders qualifi ed according to the current nuclear standards
• All our equipment for the nuclear industry is manufactured according to nuclear standards and quality assurance
Our resources• 3,400 employees in the world
• 23 production sites
• Branches in 25 countries
• Agents in more than 50 countries
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com 3
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
Intr
oduc
tion
Med
ium
Effi
cien
cyH
igh
Effi c
ienc
yVe
ry H
igh
Effi c
ienc
yAd
sorp
tion
Casi
ngs
and
fi lte
rsfo
r co
ntai
nmen
t sys
tem
sCo
ntai
nmen
t equ
ipm
ent
Equi
pmen
t for
tem
pora
ry v
entil
atio
nAc
cess
orie
s
… at your service
TrainingCamfi l Farr Academy, a recognized training center
Become the air fi ltration specialist in your company.
Contact us to receive the detailed program for this training course:Certifi ed training centreTel. : +33 (0)1 46 52 48 28Fax : +33 (0)1 47 60 17 81www.camfilfarr.com/ProduitsServices/Centre-de-formationContact : françoise.perez@camfi l.fr
Training on “Raising awareness for fi eld staff” – On-site• Handling fi ltration cells.• Advice on storage conditions.• Unloading/loading actived carbon.• Recommended Maintenance of fi ltration
equipment.
We recommend monitored and regular training of your staff.
Make your life easier
Support and technicalassistance in the fi eldOur team of engineers and qualifi ed tech-nicians is at your service for:
Your new installations:• Assistance for assembling equipment
(Tight lock casings, SOFILTRAD iodine traps, etc.).
• Assistance for the installation of fi ltra-tion items (carbon loading, implemen-ting fi ltering cells, etc.).
Maintenance:• Equipment diagnostics.
Keeping supplied equipment operating
CAMFIL FARR commits itself to ensuring the supply of many spare parts used in manu-facturing its equipment.
Camfi l Farr maintains detailed record of all products supplied to your plant; making fi lter maintenance and ordering of spare parts convenient and consistent.
Personalized deliverieson request• Regular scheduled replacement.• Special labelling requirements.
Spare parts: clamping frame Casing: identifi cation plateFilter: controlling and traceability
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com4
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
IntroductionM
edium Effi ciency
High Effi ciency
Very High Effi ciency
AdsorptionCasings and fi lters
for containment system
sContainm
ent equipment
Equipment for
temporary ventilation
Accessoires
History
The story starts in 1928. At that time Mr Poelman was a chemical engineer and worked in a workshop for manufacturing costume jewellery. He developed a pleated paper fi lter to protect workers from collo-dion (a mixture of ether, nitrocellulose, and ethyl alcohol. During an exhibition, the military became very interested in the po-tential uses of the fi lter. Mr Poelman then started manufacturing fi lters for breathing masks for the French army.The company ULTRAFILTRES POELMAN was created in 1930.During the 1930s and 1940s, the com-pany developed fi lter papers for military and civilian use. Thus, in 1935-1936, ULTRAFILTRES POELMAN equipped the Maginot line with fi lters and then civilian shelters. At the same time, Mr Poelman became interested in air fi ltration for indus-trial customers. Thus, in 1953, the fi rst fi l-ters for glove boxes appeared (derivatives of military cartridges) and the fi rst fi lters in the shape of V-packs. These fi lters used mini-pleats pleated paper technology.In the same year, the company became SCHNEIDER-POELMAN.1954 marked the start of a co-opera-tion with CEA (Commisariat à l’Energie Atomique).At the same time, 1950 saw the creation of an “air fi ltration” department within the SOCIÉTÉ FRANÇAISE D’ACETYLÈNE (SFA), a branch of Soudure Autogène Française (Air Liquide Group).In 1959 development began on a media based upon glass fi ber. Prior to the use of glass fi bers; fl ammable cellulosic paper was used for fi ltration media.
Saint Gobain was entrusted by the CEA to develop this media as the result of a fi re at a fuel reprocessing site.The manufacture of the fi rst cells started at the SFA factory in 1963.In 1967, SOFILTRA was created, from a merger between the companies SAINT GOBAIN TECHNIQUES NOUVELLES and SFA.In 1976, in order to counteract foreign competition, requested by the French administration and EDF, SOFILTRA and SCHNEIDER-POELMAN merged to create SOFILTRA-POELMAN. This new company then brought together all the experience already acquired over several years in terms of air fi ltration in a nuclear environ-ment with, on the one hand, the cage-ins-talled V-pack fi lter technology developed by Schneider-Poelman, and, on the other hand, a system of tight lock casing cells inherited from Sofi ltra.In 1990, the Saint Gobain group sold Sofi ltra-Poleman to Camfi l in order to focus on its core glass business. This merger for-med SOFILTRA-CAMFIL.In 1994, the company was renamed CAMFIL. Finally, in 2001, following the buyout of the American company FARR, Camfi l became CAMFIL FARR, the world leader in air fi ltration.Since the 1970s, the development of CAMFIL FARR has accompanied the de-velopment of researches and of the french nuclear industry with the manufacture of products like Sofi lair, CTHEN fi lters, prefi l-ters, settling tank canisters, carbon fi lters and casings.
SOFILTRA-POELMAN
ultrafiltres poelman
1928 : Mr Poelman, a chemical engineer in the chemical industry specialising in jewellery, designed the first pleated paper filters to protect workers from the smell of collodion. These filters were later be used by the French army.
1959 : Saint Gobain and CEA“Atomic Energy Commission” become partners in order to develop a glass fiber filter for the nuclear industry.
1977 : AREVA buys SGN(Saint Gobain Nucléaire) and baptises the new company: SociétéGénérale pour les techniques Nouvelles (SGN).
1976 : To meet the requirements of the vast NPP programme demanded by the French government, EDF asks Saint Gobain to merge the companies SOFILTRA and POELMAN.
1967 : Creation of SOFILTRA by the merger of the companies SFA and SGTN.
1930 : Creation of ULTRAFILTRES POELMAN. 1951 : Creation of an air filtration
department in the SOCIETE FRANCAISE D’ACETYLENE, a branch of LA SOUDURE AUTOGENE FRANCAISE.
1960 : In order to meet the requirements of the French CEA, creation of an air filtration department (Saint Gobain Nuclear).
EDF
CEA
AREVA
SAINT GOBAINTECHNIQUES NOUVELLES
SFA AIR LIQUIDE
SAINT GOBAINNUCLEAIRE
SAINT GOBAINCORPORATION
From Poelman to Camfi l Farr
From Zoéto the present dayThe story of nuclear power in France began on 15th December 1948, when a team of researchers led by Frédéric Joliot, were awarded the Nobel prize for chemistry. They created the fi rst French fuel cell, Zoé, by the fi ssion of uranium atoms.
Zoé allowed initial studies to be carried out on reactors, to produce radioelements vital for research and to make all the mea-surements and all the experiments needed for the design of the future fl eet of French nuclear reactors.
Since then, nuclear power has become a real industry with its specifi c points and its specifi c actors. These are involved in the extraction of uranium ore, in the transfor-mation of this ore into enriched uranium, in the recycling of uranium or even, for example, in the construction of nuclear power stations or waste processing.
The main application of nuclear power is for the production of electricity: Eighty percent of the electricity produced in France today comes from nuclear power.
However, with the progress of knowledge, new applications have appeared. So, to-day, nuclear power allows us to date, in particular, natural phenomena thanks to isotopic dating and offers a diagnostic pos-sibility thanks to medical imagery.
Camfi l Farr FranceA 50 years experience in
the nuclear industry
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com 5
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
Intr
oduc
tion
Med
ium
Effi
cien
cyH
igh
Effi c
ienc
yVe
ry H
igh
Effi c
ienc
yAd
sorp
tion
Casi
ngs
and
fi lte
rsfo
r co
ntai
nmen
t sys
tem
sCo
ntai
nmen
t equ
ipm
ent
Equi
pmen
t for
tem
pora
ry v
entil
atio
nAc
cess
orie
s
Camfi l Farr has been a major partner of the nuclear industry, since the end of the 1950s, Camfi l Farr has actively contribu-ted to equip the CEA basic nuclear ins-tallations, electricity production centres, military research centres, ion or particle accelerators and power lasers for scientifi c research.
Moreover, the equipment usually foreseen for nuclear activity, by its design which guarantees optimum containment, is used in the high-tech pharmaceutical research fi eld where it is necessary for work in P3 to P4 category laboratories.
The main developments are:• Electricity production centres (900 /
1300 / 1450 MWE) and new genera-tion EPR (China, France).
• Saclay, Fontenay Atomic Research Centres.
• Very long and very short duration waste storage centres.
• Fuel reprocessing centres (France, Japan).
• Military research centre.• Particle accelerators (Cyclotron medical
& research).• Power laser for research (Laser Méga
Joule, LIL).• Microbiological research centre (life
science).
EDF chose to equip 78 nuclear reactors with Camfi l Farr solutions:
58 of these reactors are located in France.
There are:• 34 x 900 MW.• 20 x 1300 MW.• 4 x 1450 MW.
The others are located in Belgium, Swe-den, South Africa, South Korea, China and in Spain.
AREVA and its branches also trust Camfi l Farr:
3 reprocessing centres, in particular, use our material:• Marcoule (France).• La Hague (France).• Tokai (Japan).
History
Main references
CAMFIL France was given the “AREVA Supplier” label for two years running.
In June 2010, AREVA awarded the CAMFIL company the “AREVA Supplier” label during an offi cial ceremony.
With this label, created by the AREVA group in 2009, AREVA emphasized its ties with partner companies that make a substantial contribution to the company’s suc-cess.
AREVA has renewed its trust in Camfi l that had already been given this award the previous year.This label is based on nearly twenty fi ve quality requirements and respect of sus-tainable development and competitiveness values.Investment in innovation and research as well as the attention given to safety, securi-ty and the environment were thus decisive points for the awarding of this distinction.
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com6
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
IntroductionM
edium Effi ciency
High Effi ciency
Very High Effi ciency
AdsorptionCasings and fi lters
for containment system
sContainm
ent equipment
Equipment for
temporary ventilation
Accessoires
Quality – Safety – Environment – Energy
Recognised and lastingknow-how CAMFIL is a partner in the French nu-clear development programme and today benefi ts from recognised expertise in the Protection and Security fi eld. CAMFIL pro-ducts have supported our clients in their development from Very High Effi ciency fi l-ters to tight lock casings, the fi nal barriers in nuclear installations.
For this we have a Quality culture acquired over a long time based on manufacturing and verifi cation processes, components and qualifi ed personnel.
A Quality Management System that complies with ISO 9001Today, Quality is not only linked to product manufacturing but is also part of all the company’s processes (see chart).
Through ISO 9001 certifi cation, we have implemented all the foundations of the quality management system in terms of:
Integrated Management Systems• System steering: this is described
through our management process. The QSEE Manager runs this, in particular, via a network of QSE contacts integrated into different departments.
• Resource management: the support services make available to Camfi l Farr skills adapted to making its products and services and supply and maintain the infrastructures needed for the com-pany to run effi ciently.
• Documentation management: the qua-lity documentation is considered to be a work tool allowing us to standardise our work methods and promote adaptability. Records are made for our customers as a proof of their actual implementation.
• Traceability: the products are all put into batches in relation to the manu-facturing order number and, for Very High Effi ciency products, a unique serial number allows us to trace the produc-tion and verifi cation operations.
• Measure, analyse, improvement: at the different stages of the production process, some controls are made by qualifi ed staff with calibrated material, and the results of these controls are analysed.
We have also focused on continuous im-provement principle the crowning achieve-ment of the Group’s industrial policy, the “Green Tornado”. The objective being to continuously improve ourselves in 4 prio-rity areas, which are:• security,• quality and sustainable development,• service,• costs, while respecting the company’s funda-mental values.
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com 7
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
Intr
oduc
tion
Med
ium
Effi
cien
cyH
igh
Effi c
ienc
yVe
ry H
igh
Effi c
ienc
yAd
sorp
tion
Casi
ngs
and
fi lte
rsfo
r co
ntai
nmen
t sys
tem
sCo
ntai
nmen
t equ
ipm
ent
Equi
pmen
t for
tem
pora
ry v
entil
atio
nAc
cess
orie
s
Far beyond Quality …a Sustainable Development Policy The Camfi l FARR group declares its deter-mination to contribute every day to the quality of the air that we breathe and has followed, for nearly half a century, the path of Sustainable Development. This approach can be seen in the setting up of a Sustainable Development Policy, Camfi lcaring.
In 2009, the Camfi l Farr group published the First Sustainable Development Report in the world on air fi ltration. This report puts into words our response to the chal-lenges of air pollution and global warming as well as the key focuses of the company for our employees, our clients and the stakeholders.
Therefore, it was quite natural for us to go beyond the system of Quality Management.
Quality – Safety – Environment – Energy
Sustainable Development PolicyThe Saint-Martin-Longueau factory set up an Environment Management System and obtained ISO 14001 certifi cation as soon as 2003.
The specifi c aspects of the ISO 14001 standard are dealt with through identifi ca-tion procedures for environmental aspects, regulatory monitoring, waste processing, and prevention of risk situations which complete the pre-existing provisions of the quality management, continuous improve-ment and process mastery systems.
In the same approach, concerned with the health and safety of our personnel and the companies working on our production site, we set up a Safety Management System in accordance with standard OHSAS 18001 and based on the permanent reviewing of our Single Document.
Finally, in accordance with our environ-mental policy, many actions have been im-plemented since 2006 in order to improve the energy performance of our production site. This will can be illustrated by the set-ting up of an Energy Management System and being awarded EN 16001 certifi ca-tion in May 2011.
All these Management systems have been integrated (QSEE) in order to steer them as effi ciently as possible.
For more information (ISO certifi cates, QSE manual, Sustainable Development review, etc.) please go to:www.camfi lfarr.com/Documentation
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com8
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
IntroductionM
edium Effi ciency
High Effi ciency
Very High Effi ciency
AdsorptionCasings and fi lters
for containment system
sContainm
ent equipment
Equipment for
temporary ventilation
Accessoires
The Camfil Farr ADVANTAGES
CAMFIL FARR solutions in the nuclear industry
page 12 page 18 see general catalogue page 19 page 26
page 78 page 63 page 82 page 34 page 16
page 57 page 58 page 50 page 28 page 24
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com 9
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
Intr
oduc
tion
Med
ium
Effi
cien
cyH
igh
Effi c
ienc
yVe
ry H
igh
Effi c
ienc
yAd
sorp
tion
Casi
ngs
and
fi lte
rsfo
r co
ntai
nmen
t sys
tem
sCo
ntai
nmen
t equ
ipm
ent
Equi
pmen
t for
tem
pora
ry v
entil
atio
nAc
cess
orie
s
Guaranteed effi ciency During the design and the sizing of any item, it is essential to consider all the data for each other item included in the fi ltration barrier.
For example, clamping equipment (tray, shafts, cams, etc.) is designed depending on the mechanical performances of the fi lter components (frame, gasket, sealant, etc.). The consideration of all this data determines the sizing and the design of the casing gasket seat.
CAMFIL FARR designs, manufactures and controls all these items (fi lter, casing, and damper) depending on the different requirements.
This ensures guaranteed results during in situ tests and the effi ciency of the installation when operating.N.B.: Our responsibility is expressly limited to all the CAMIL FARR model fi ltering barriers. In particular, it cannot, in any case, be claimed in the case of assembly with equipment from different brands.
The Camfil Farr ADVANTAGES
The unique specifi cations of our equipment
Temperature resistanceConsidering the importance of fi ltration barriers, the French authorities wanted to catego-rise fi lters equipping certain fi ltration levels as “Important Security Items” (decree dated 10 August 1984).
For this purpose, the CTHEN (Centre Technique Homologations des Equipements Nu-cléaires – Technical Center for Nuclear Equipment Accreditation) had the authority over accreditation of the equipment. CAMFIL FARR developed products able to meet these requirements.
Moreover, CAMFIL FARR carried out a series of tests with IRSN on a fi ltration barrier (casing + fi lter), based on the CTHEN specifi cations. During this programme, other dyna-mic tests (combination of pressure – temperature) at values higher than those imposed by the CTHEN specifi cations were also carried out. That way, verifi cations of the overall tightness (internal/external) of casings are made.
Now, only these tests allow CAMFIL FARR to guarantee the temperature resistance of a complete fi ltration barrier (fi lter + casing).
A fi ltration barrier is an operational device installed in a ventilation network. It is composed of a fi ltering item (fi lter), its casing, platform, casing, and dampers.
Seismic resistanceThe tests are made on a vibrating table, and the seismic resistance calculations for our equipment allow CAMFIL FARR to defi ne the different components of the fi ltration barrier items.
In case of seismic, the wave induced is transmitted to the fl oor or the walls of buildings. These are transmitted to the casing via different anchor points.
The shock waves that the fi ltering item (fi lter) is subject to are different to those of the fl oor. Actually, they result from the intrinsic characteristics of the casing, i.e. its geometry, its mass, its materials, etc. The same goes for the shock waves that the damper is sub-ject to.
In fact, shock waves to the fi lter or the damper are the results of the concatenation of seismic spectres and the intrinsic characteristics of the casing.
That is why validating the seismic resistance of a fi ltration barrier or a damper can only be made taking into account the fi lter + casing combination.
The technical data for each of the items making up this fi ltering barrier are vital for the calculations allowing us to validate the seismic resistance.
For over 40 years, CAMFIL FARR has capitalised on all this technical data (real tests and calculations) in order to meet your requirements.
Notes
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com10
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
IntroductionM
edium Effi ciency
High Effi ciency
Very High Effi ciency
AdsorptionCasings and fi lters
for containment system
sContainm
ent equipment
Equipment for
temporary ventilation
Accessoires
Medium Efficiency
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com 11
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
Intr
oduc
tion
Med
ium
Effi
cien
cyH
igh
Effi c
ienc
yVe
ry H
igh
Effi c
ienc
yAd
sorp
tion
Casi
ngs
and
fi lte
rsfo
r co
ntai
nmen
t sys
tem
sCo
ntai
nmen
t equ
ipm
ent
Equi
pmen
t for
tem
pora
ry v
entil
atio
nAc
cess
orie
s
TM SHOCK 2 IN 1
page 15
CAMMETAL
page 14
PLEATED GLASS FIBER FILTER
page 13
CMJ VK100
page 12
CONTENTS
SPARK ARRESTER FILTERS
page 16
Medium Efficiency
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com12
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
IntroductionM
edium Effi ciency
High Effi ciency
Very High Effi ciency
AdsorptionCasings and fi lters
for containment system
sContainm
ent equipment
Equipment for
temporary ventilation
Accessoires
CMJ VK100
ADVANTAGES• Maximum arresting capacity
• Can be used with high hygrometry
• High airfl ows
• Fire classifi cation M1
Media: Glass fi ber (fi re classifi cation M1) with increasing density.
Frame: Frame made of shaped galvanized steel sheet metal closed by rivets.
Gasket: Soft alveolar polyvinyl chloride (PVC) 15x10mm or without a gasket depending on model.
Grid: Galvanized meshing 25x25 on each side.
EN 779 Effi ciency: 2002: G3.
Gravimetric effi ciency: 89%.
Eurovent effi ciency 4/5: EU3.
Recommended fi nal pressure drop: 250 Pa.
Maximum airfl ow: Nominal airfl ow.
Temperature: 60° C or 120° C maximum in continuous service depending on model.
Retention: Thanks to the growing density of the glass fi bers making up the media and the impregnation of them with special oil, these fi lters have a high retention power that may reach 2000 gr/m².
Mounting systems: In tight lock casing, assemblabled frames or platforms.
Reference Model Dimensions (WxHxD) mm
Effi ciencyEN 779 : 2002
Media area m2
Airfl ow / Nominal P m3/h / Pa
Temperature T°C Gasket Calorifi c
potential MJUnit mass
kgUnit volume
m3
1450.61.00 CMJSOFGLASS3 610x305x50 G3 0.2 2000 / 80 120 none 0.5 1.7 0.01
1450.62.00 CMJSOFGLASS3 610x610x50 G3 0.4 4000 / 80 120 none 0.5 2.5 0.02
1450.97.00 CMJSOFGLASS3 610x305x50 G3 0.2 2000 / 80 120 PVC 1.7 0.01
1450.90.00 CMJSOFGLASS3 610x610x50 G3 0.4 4000 / 80 120 PVC 2.5 0.02
1450.93.00 (a) CMJSOFGLASS3 610x305x50 G3 0.2 2000 / 80 120 PVC 1.7 0.01
1450.91.00 (a) CMJSOFGLASS3 610x610x50 G3 0.4 4000 / 80 120 PVC 2.5 0.02
1450.65.00 (b) CMJSOFGLASS3 610x610x50 G3 0.4 4000 / 80 60 PVC 2.5 0.02
Other dimensions available on request.
(a) Models 1450.93.00 and 1450.91.00 are intended for equipping tight lock casings and so their gasket is on the upstream side and they are fi tted with a prehension ring (on the side of 305 mm for 1450.93.00).
(b) Media and grids held upstream and downstream by hot melt adhesive lines.
Medium Efficiency
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com 13
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
Intr
oduc
tion
Med
ium
Effi
cien
cyH
igh
Effi c
ienc
yVe
ry H
igh
Effi c
ienc
yAd
sorp
tion
Casi
ngs
and
fi lte
rsfo
r co
ntai
nmen
t sys
tem
sCo
ntai
nmen
t equ
ipm
ent
Equi
pmen
t for
tem
pora
ry v
entil
atio
nAc
cess
orie
s
PLEATED GLASS FIBER FILTER
ADVANTAGES• Performance guarantee sheet
according to model
• Large fi ltering surface
• Media sealed into the frame
• Very good mechanical rigidity
Applications: Prefi ltration for High Effi ciency and Very High Effi ciency fi lters. Equipment for of air handling units.
Type: Pleated glass fi ber fi lter.
Media: glass fi ber (fi re certifi cation M1).
Sealant: Synthetic or polyurethane resin (fi re classifi cation M3) depending on model.
Frame: Galvanized steel, except 1413.12.00: stainless steel.
Gasket: Semi-ring Ø 15 mm in one single piece, made of neoprene foam or alveolar PVC 15x10 mm.
EN 779 2002 Effi ciency: G3.
Gravimetric effi ciency: 85%.
Eurovent effi ciency 4/5: EU3.
Recommended fi nal pressure drop: 500 Pa.
Maximum Airfl ow: Nominal Airfl ow.
Temperature: 60° C or 120° C maximum in continuous service according to type.
Mounting systems: In tight lock casings, assemblable frames or platforms.
Reference Model Dimensions (WxHxD) mm
Effi ciencyEN 779 : 2002
Media area m2
Airfl ow / Nominal P
m3/h / Pa
Temperature T°C Sealant Gasket
Calorifi c potential
MJ
Unit mass
kg
Unit volume
m3
1405.09.00 Glass fi ber fi lter 495x495x50 G3 1.48 2300 / 50 60 Synthetic resin PVC 11 1.5 0.01
1413.01.00 Glass fi ber fi lter 610x610x50 G3 2.27 3400 / 50 120 Polyurethane None 25 2.5 0.02
1413.02.00 Glass fi ber fi lter 610x610x50 G3 2.27 3400 / 50 120 Polyurethane Neoprene 2.5 0.02
1413.09.00 Glass fi ber fi lter 610x610x50 G3 2.27 3400 / 50 60 Synthetic resin PVC 14 2.1 0.02
1413.10.00 (a) Glass fi ber fi lter 610x610x50 G3 2.27 3400 / 50 60 Synthetic resin PVC 14 2.1 0.02
1413.12.00 (a+b) Glass fi ber fi lter 610x610x50 G3 2.27 3400 / 50 60 Synthetic resin PVC 14 2.1 0.02
1413.30.00 (a) Glass fi ber fi lter 610x305x50 G3 1.38 1700 / 50 60 Synthetic resin PVC 7 1.4 0.01
(a) Ring for assembly in tight lock casings.
(b) Stainless steel frame.
Medium Efficiency
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com14
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
IntroductionM
edium Effi ciency
High Effi ciency
Very High Effi ciency
AdsorptionCasings and fi lters
for containment system
sContainm
ent equipment
Equipment for
temporary ventilation
Accessoires
CAMMETAL
ADVANTAGES• Can be used at high temperature
• Protects VHE fi lters
Applications: Installation in nuclear ventilation circuit for pre-fi ltration before VHE fi lters.
Type: Medium effi ciency metal knit.
Media: Overlaying of metal knit (galvanized or stainless steel) layers.
Frame: Galvanized or stainless steel depending on model.
Gasket: Polyvinyl chloride (PVC) foam 15x10 mm or triangular compact silicon.
Grid: Galvanized or stainless steel depending on model.
Handle: Prehension ring (on the small side for 610x305 fi lters).
EN 779 2002 Effi ciency: G3.
Gravimetric effi ciency: 85%.
Eurovent effi ciency 4/5: EU3.
Recommended fi nal pressure drop: 200 Pa.
Maximum Airfl ow: Nominal Airfl ow.
Temperature: 120 or 200° C maximum in continuous service depending on model.
Mounting systems: In tight lock casings or platforms.
Reference Model Dimensions (WxHxD) mm
Effi ciencyEN 779 : 2002
Media area m2
Airfl ow / Nominal P m3/h / Pa
Temperature T°C Gasket Calorifi c
potential MJUnit mass
kgUnit volume
m3
1460.01.01 TM Galva 610x610x50 G3 0.4 3400 / 55 120 PVC 5.4 0.02
1460.01.02 TM Galva 610x610x50 G3 0.4 3400 / 55 200 Silicon 5 5.4 0.02
1460.97.01 TM S/Steel 610x610x50 G3 0.4 3400 / 55 120 PVC 5.4 0.02
1460.97.02 TM S/Steel 610x610x50 G3 0.4 3400 / 55 200 Silicon 5 5.4 0.02
1464.11.02 TM Galva 610x305x50 G3 0.2 1500 / 45 200 Silicon 2.5 2.9 0.01
1464.11.03 TM Galva 610x305x50 G3 0.2 1500 / 45 120 PVC 2.9 0.01
1464.31.02 TM S/Steel 610x305x50 G3 0.2 1500 / 45 200 Silicon 2.5 2.9 0.01
1464.31.03 TM S/Steel 610x305x50 G3 0.2 1500 / 45 120 PVC 2.9 0.01
Other dimensions available on request.
Medium Efficiency
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com 15
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
Intr
oduc
tion
Med
ium
Effi
cien
cyH
igh
Effi c
ienc
yVe
ry H
igh
Effi c
ienc
yAd
sorp
tion
Casi
ngs
and
fi lte
rsfo
r co
ntai
nmen
t sys
tem
sCo
ntai
nmen
t equ
ipm
ent
Equi
pmen
t for
tem
pora
ry v
entil
atio
nAc
cess
orie
s
TM SCHOCK 2 IN 1
ADVANTAGES• Can be used at high
temperature
• Protects VHE fi lters from sparks and glowing particles
Applications: Installation in nuclear ventilation circuit to protect VHE fi lters from sparks and incandescent particles.
Type: Combination of baffl es and medium effi ciency metal knit.
Media: Metal baffl es and overlaying of metal knit (galvanized or stainless steel) layers.
Frame: Galvanized or stainless steel depending on model.
Gasket: Semi-ring Ø 15 mm in one single piece, made of neoprene depending on model.
Grid: meshing 25x25.
Handle: Prehension ring (on the small side for 610x305) fi lters).
EN 779: 2002 Effi ciency: G2.
Gravimetric effi ciency: 65%.
Eurovent effi ciency 4/5: EU3.
Recommended fi nal pressure drop: 200 Pa.
Maximum Airfl ow: Nominal Airfl ow.
Temperature: 120 or 200° C maximum in continuous service depending on model.
Mounting systems: In tight lock casings or platforms.
Reference Model Dimensions (WxHxD) mm
Effi ciencyEN 779 : 2002
Media area m2
Airfl ow / Nominal P m3/h / Pa
Temperature T°C Gasket Calorifi c
potential MJUnit mass
kgUnit volume
m3
1465.60.08 TM Shock 2 in 1 S/Steel 610x305x50 G2 0.2 1500 / 380 200 - - 4.4 0.01
1465.60.12 TM Shock 2 in 1 S/Steel 610x610x50 G2 0.4 3400 / 380 120 Neoprene 2.9 8.8 0.02
Other dimensions available on request.
Medium Efficiency
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com16
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
IntroductionM
edium Effi ciency
High Effi ciency
Very High Effi ciency
AdsorptionCasings and fi lters
for containment system
sContainm
ent equipment
Equipment for
temporary ventilation
Accessoires
SPARK ARRESTER FILTERS
ADVANTAGES• Can be used at high temperature
• Protects VHE fi lters from sparks and incandescent particles
Applications: Installation in nuclear ventilation circuit to protect VHE fi lters from sparks and incandescent particles.
Type: Medium effi ciency metal knit.
Media: Overlaying of metal knit layers made of stainless steel.
Frame: Stainless steel.
Gasket: Semi-ring Ø 15 mm in one single piece, made of neoprene depending on model.
Grid: Meshing 25x25 and metal knit on the downstream side.
Handle: Prehension ring (on the small side for 610x305) fi lters).
EN 779: 2002 Effi ciency: G3.
Gravimetric effi ciency: 85%.
Eurovent effi ciency 4/5: EU3.
Recommended fi nal pressure drop: 200 Pa.
Maximum Airfl ow: Nominal Airfl ow.
Temperature: 120 or 200° C maximum in continuous service depending on model.
Mounting systems: In tight lock casings or platforms.
Reference Model Dimensions (WxHxD) mm
Effi ciencyEN 779 : 2002
Media area m2
Airfl ow / Nominal P m3/h / Pa
Temperature T°C Gasket Calorifi c
potential MJUnit mass
kgUnit volume
m3
6271.98.00 S/S Spark Arrester 610X610X50 G3 0.4 1500 / 320 120 Neoprene 2.9 5.4 0.02
6271.99.00 S/S Spark Arrester 610X305X50 G3 0.2 3400 / 320 200 - - 2.9 0.01
Other dimensions available on request.
High Efficiency
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com 17
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
Intr
oduc
tion
Med
ium
Effi
cien
cyH
igh
Effi c
ienc
yVe
ry H
igh
Effi c
ienc
yAd
sorp
tion
Casi
ngs
and
fi lte
rsfo
r co
ntai
nmen
t sys
tem
sCo
ntai
nmen
t equ
ipm
ent
Equi
pmen
t for
tem
pora
ry v
entil
atio
nAc
cess
orie
s
POLYV-PACK CELLS 95% DOP
page 19
OPAKAIR HT120
page 18
CONTENTS
High Efficiency
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com18
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
IntroductionM
edium Effi ciency
High Effi ciency
Very High Effi ciency
AdsorptionCasings and fi lters
for containment system
sContainm
ent equipment
Equipment for
temporary ventilation
Accessoires
OPAKAIR HT120
ADVANTAGES• Large fi ltering surface
• Long lifetime
• High airfl ow
Applications: High Effi ciency fi lter for new and transfer air circuit for nuclear industries.
Type: High Effi ciency fi lter with a large fi ltering surface.
Media: Glass fi ber paper (fi re classifi cation M1).
Separators: Glass fi ber thread.
Sealant: Polyurethane.
Frame: Galvanized steel.
Gasket: EPDM gasket semi-ring diameter 15mm.
Handle: Only one 1514.12.00 and 1514.13.00.
EN 779: 2002 Effi ciency: F7 and F8.
Spectral effi ciency: 85 and 95%.
Eurovent effi ciency 4/5: EU7 and EU8.
Recommended fi nal pressure drop: 450 Pa.
Maximum Airfl ow: 1.10 x nominal Airfl ow.
Temperature: 120° C maximum in continuous service.
Mounting systems: In tight lock casings, platforms or “tub” type assemblable frames.
Reference Model Dimensions (WxHxD) mm
Effi ciencyEN 779 : 2002 Media area m2 Airfl ow / Nominal P
m3/h / PaCalorifi c potential
MJ Unit mass kg Unit volume m3
1514.52.00 OPAKAIR HT120 305x610x292 F7 10 2250 / 110 72 9 0.06
1514.12.00 OPAKAIR HT120 610x610x292 F7 20 4500 / 110 144 18 0.11
1514.53.00 OPAKAIR HT120 305x610x292 F8 10 2250 / 130 72 9 0.06
1514.13.00 OPAKAIR HT120 610x610x292 F8 20 4500 / 130 144 18 0.11
High Efficiency
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com 19
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
Intr
oduc
tion
Med
ium
Effi
cien
cyH
igh
Effi c
ienc
yVe
ry H
igh
Effi c
ienc
yAd
sorp
tion
Casi
ngs
and
fi lte
rsfo
r co
ntai
nmen
t sys
tem
sCo
ntai
nmen
t equ
ipm
ent
Equi
pmen
t for
tem
pora
ry v
entil
atio
nAc
cess
orie
s
POLY V-PACK CELLS 95% DOP
ADVANTAGES• Performance guarantee sheet
• Large fi ltering surface
Applications: High Effi ciency fi lter for new air and transfer circuits for nuclear industries.
Type: Poly V-pack High Effi ciency fi lter.
Media: Glass fi ber paper (fi re classifi cation M1).
Separators: Glass fi ber thread.
Sealant: Polyvinyl chloride (PVC - fi re classifi cation M2).
Frame: Galvanized steel or stainless steel Z2 CN18-10 (304L) or Z8-C17 (F17) depending on model.
Gasket: Semi-ring Ø 15mm made of neoprene in one single piece.
Handle: 1 on side 610 parallel to V-packs.
DOP Effi ciency 0.3 µm: 95%.
Eurovent effi ciency 4/4: EU10.
Recommended fi nal pressure drop: 600 Pa.
Mechanical resistance: 4000 Pa per airfl ow increase.
Maximum airfl ow: Nominal airfl ow.
Temperature: 120° C maximum in continuous service.
Mounting systems: In tight lock casings or platforms.
Reference Model Dimensions (WxHxD) mm
Effi ciency DOP
Media area m2
Airfl ow / Nominal P m3/h / Pa Frame Calorifi c
potential MJ Unit mass kg Unit volume m3
1505.43.00 Galva poly V-pack 305x610x292 95% 20.5 1500 / 160 Galvanized steel 67 14 0.05
1506.47.00 Galva poly V-pack 610x610x292 95% 41 3400 / 160 Galvanized steel 128 23 0.11
Notes
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com20
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
IntroductionM
edium Effi ciency
High Effi ciency
Very High Effi ciency
AdsorptionCasings and fi lters
for containment system
sContainm
ent equipment
Equipment for
temporary ventilation
Accessoires
Very High Efficiency
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com 21
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
Intr
oduc
tion
Med
ium
Effi
cien
cyH
igh
Effi c
ienc
yVe
ry H
igh
Effi c
ienc
yAd
sorp
tion
Casi
ngs
and
fi lte
rsfo
r co
ntai
nmen
t sys
tem
sCo
ntai
nmen
t equ
ipm
ent
Equi
pmen
t for
tem
pora
ry v
entil
atio
nAc
cess
orie
s
SETTLING TANK CANITERS
page 29
SETTLING TANK CANITERS
page 28
DELTAFIL
page 23
CTHEN-APPROVED SOFILAIR FILTERS
page 26
PTFE VHE POLY V-PACK FILTERS
page 25
VHE POLY V-PACK
page 24
CONTENTS
GENERAL POINTS
page 22
PRINCIPLES
The applications of VHE fi lters can be classifi ed in two very different categories depending on the required aim. These are:• obtaining an atmosphere with a very
low numerical concentration in particles or in micro-organisms for the manufac-ture of very delicate products;
• arresting contaminants that are dange-rous for people, this is the case with the nuclear industry.
TECHNICAL SPECIFICATIONSRELATING TO VHE FILTERS
The French specifi cations defi ned in “The guide for the ventilation of nuclear installa-tions” mentions that the decontamination factor measured on the benchtest for VHE fi lters will be, at nominal airfl ow, higher than 5000 (effi ciency over 99.98%) according to the sodium fl uorescein aerosol method for a median of Ø 0.15 µm (AFNOR standard NFX 44-011) and that the admissible fi nal pressure drop will not be lower than 1000 Pa.
This guide also mentions, for installations, that the decontamination factor measured on receipt and during operating has to be higher than the value set by the technical specifi cations and in no case lower than 1000 with the sodium fl uorescein test (NF M 62-303 standard).
Uranine test: fl uorimetric method the measuring of which consists in sampling the uranine aerosol upstream and downstream of the test fi lter, using two sampling fi lters, to extract the uranine from these fi lters by washing and to titrate the washing solutions by measuring their fl uorescence. The penetration of the fi lter is the ratio of the titers of the two solutions.
The VHE fi lters must have successfully undergone qualifi cation tests carried out in a laboratory of the Atomic Energy Commission (CEA) or the Institute of Radioprotection and Nuclear Safety (IRSN). They should to be the subject of “Performance Guarantee” sheets based on the results of these tests which cover the effi ciency, the pressure drop and mechani-cal, thermal resistance, etc.
SOFILAIR CTHEN have been developed to meet specifi ca- tions (including, in particular, dynamic thermal resistance tests) established by the Technical Centre for the Accreditation of Nuclear Equipment (CTHEN). The Camfi l FARR Air fi lters SOFILAIR CTHEN were the fi rst ones to be accredited at 200°C/2h by CTHEN.
AMERICAN SPECIFICATIONS listed in the US Nuclear Regulatory Commission Regulatory Guide 1.52 stipulate that VHE fi lters – HEPA Filters – should comply with American standards ASME AG-1 (formerly military standard MIL- F 51.079 for fi lter paper) and MIL -F-51.068 for the fi lter itself. The latter, which is related to the American design with deep pleats, imposes minimum DOP effi ciency of 99.97% with 0.3 micron particles. Moreover, it mentions the criteria for non-fl ammability, humidity and temperature resistance that the fi lters have to meet. For nuclear applications, the Regulatory Guide 1.52 imposes metal frames.
The Camfi l FARR VHE exceeds the requirements of the French and American standards.
IRRADIATION RESISTANCE
The media of our VHE fi lters comply with the American standard ASME AG1 (MIL F 51079) which allows us to guarantee their integrity after irradiation (mechanical resistance, tempe- rature resistance, water resistance).
INTERNAL REQUALIFICATION
Our VHE fi lters are subject to complete requalifi cation in the CAMFIL laboratory. This requalifi cation includes all the CEA or IRSN tests, humidity resistance and a test for the radiation resistance of the sealants, gaskets and media. This regular requalifi -cation allows us to guarantee the integrity of our fi lters in extreme conditions.
Very High Efficiency
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com22
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
IntroductionM
edium Effi ciency
High Effi ciency
Very High Effi ciency
AdsorptionCasings and fi lters
for containment system
sContainm
ent equipment
Equipment for
temporary ventilation
Accessoires
PRINCIPLES
The applications of VHE fi lters can be classifi ed in two very different categories depending on the required aim. These are:• obtaining an atmosphere with a very
low numerical concentration in particles or in micro-organisms for the manufac-ture of very delicate products;
• arresting contaminants that are dange-rous for people, this is the case with the nuclear industry.
TECHNICAL SPECIFICATIONSRELATING TO VHE FILTERS
The French specifi cations defi ned in “The guide for the ventilation of nuclear installa-tions” mentions that the decontamination factor measured on the benchtest for VHE fi lters will be, at nominal airfl ow, higher than 5000 (effi ciency over 99.98%) ac-cording to the sodium fl uorescein aero-sol method for a median of Ø 0.15 µm (AFNOR standard NFX 44-011) and that the admissible fi nal pressure drop will not be lower than 1000 Pa.
This guide also mentions, for installations, that the decontamination factor measured on receipt and during operating has to be higher than the value set by the technical specifi cations and in no case lower than 1000 with the sodium fl uorescein test (NF M 62-303 standard).
Uranine test: fl uorimetric method the measuring of which consists in sam-pling the uranine aerosol upstream and downstream of the test fi lter, using two sampling fi lters, to extract the uranine from these fi lters by washing and to ti-trate the washing solutions by measuring their fl uorescence. The penetration of the fi lter is the ratio of the titers of the two solutions.
The VHE fi lters must have successfully undergone qualifi cation tests carried out in a laboratory of the Atomic Energy Commission (CEA) or the Institute of Radioprotection and Nuclear Safety (IRSN). They should to be the subject of “Performance Guarantee” sheets based on the results of these tests which cover the effi ciency, the pressure drop and mechani-cal, thermal resistance, etc.
SOFILAIR CTHEN have been developed to meet specifi cations (including, in par-ticular, dynamic thermal resistance tests) established by the Technical Centre for the Accreditation of Nuclear Equipment (CTHEN). The Camfi l FARR Air fi lters SO-FILAIR CTHEN were the fi rst ones to be accredited at 200°C/2h by CTHEN.
AMERICAN SPECIFICATIONS listed in the US Nuclear Regulatory Commission Regulatory Guide 1.52 stipulate that VHE fi lters – HEPA Filters – should comply with American standards ASME AG-1 (formerly military standard MIL-F-51.079 for fi lter paper) and MIL-F-51.068 for the fi lter itself. The latter, which is related to the American design with deep pleats, im-poses minimum DOP effi ciency of 99.97% with 0.3 micron particles. Moreover, it mentions the criteria for non-fl ammabi-lity, humidity and temperature resistance that the fi lters have to meet. For nuclear applications, the Regulatory Guide 1.52 imposes metal frames.
The Camfi l FARR VHE exceeds the re-quirements of the French and American standards.
IRRADIATION RESISTANCE
The media of our VHE fi lters comply with the American standard ASME AG1 (MIL-F-51.079) which allows us to gua-rantee their integrity after irradiation (mechanical resistance, temperature resis-tance, water resistance).
INTERNAL REQUALIFICATION
Our VHE fi lters are subject to complete requalifi cation in the CAMFIL laboratory. This requalifi cation includes all the CEA or IRSN tests, humidity resistance and a test for the radiation resistance of the sealants, gaskets and media. This regular requalifi -cation allows us to guarantee the integrity of our fi lters in extreme conditions.
GENERAL POINTS
Very High Efficiency
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com 23
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
Intr
oduc
tion
Med
ium
Effi
cien
cyH
igh
Effi c
ienc
yVe
ry H
igh
Effi c
ienc
yAd
sorp
tion
Casi
ngs
and
fi lte
rsfo
r co
ntai
nmen
t sys
tem
sCo
ntai
nmen
t equ
ipm
ent
Equi
pmen
t for
tem
pora
ry v
entil
atio
nAc
cess
orie
s
DELTAFIL
ADVANTAGES• Performance guarantee sheet
• Static thermal resistance
• Guaranteed dimensional tolerances
Applications: Air conditioning, ventilation and air extraction in nuclear industries and buildings.
Type: VHE V-pack.
Media: Glass fi ber paper (fi re classifi cation M1).
Separators: Glass fi ber thread.
Sealant: Mineral (fi re classifi cation M0).
Frame: Galvanized steel.
Uranine effi ciency: > 99.98%.
Uranine decontamination factor: > 5000 (NFX 44-011) or >3000 depending on airfl ow.
Recommended fi nal pressure drop: 600 Pa.
Maximum airfl ow: Nominal airfl ow.
Temperature: Static thermal resistance 200°C maximum in continuous service for 6h.
Control: Oil mist 100%.
Guarantee: This fi lter has been subject to typical tests made by the Atomic Energy Commission and is the object of a “Performance Guarantee” sheet.
Assembly system: BSS casing.
Assembly: Tightness between DELTAFIL made by using a special adhesive tape.
Accessories: Adhesive tape.
Ref 1900.10.00 : 70°C maximum in continuous service. Length: 3m.
Ref 1900.09.00 : 180°C maximum in continuous service. Length: 55 m.
Reference Model Dimensions (WxHxD) mm
Decontamination factor Uranine Media area m² Airfl ow / Nominal P
m³/h / PaCalorifi c
potential MJ Unit mass kg Unit volume m³
3306.12.00 VZ G2 600x65x202 > 3000 3.88 300 / 250 1.5 1.5 0.012
3306.12.00 VZ G2 600x65x202 > 5000 3.88 100 / 75 1.5 1.5 0.012
Very High Efficiency
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com24
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
IntroductionM
edium Effi ciency
High Effi ciency
Very High Effi ciency
AdsorptionCasings and fi lters
for containment system
sContainm
ent equipment
Equipment for
temporary ventilation
Accessoires
VHE POLY V-PACK FILTERSADVANTAGES• Performance guarantee
sheet
• Individual verifi cation
• Traceability of each fi lter
• Irradiation resistant
• Guaranteed dimensional tolerance
Applications: Air conditioning, ventilation and air extraction in nuclear industries and buildings.
Type: VHE poly V-pack fi lter.
Media: Glass fi ber paper (fi re classifi cation M1) Resistance to Gamma irradiation according to standard ASME-AG1.
Separators: Glass fi ber thread.
Sealant: PVC (fi re classifi cation M2), silicon (fi re classifi cation M1) or mineral (fi re classifi cation M0) depending on model.
Frame: Galvanized or stainless steel, depending on model.
Gasket: Semi-ring Ø 15 made of neoprene in one single piece or triangular in shape, made of compact silicon.
Handle: 1 on side 610, parallel to V-packs.
Uranine effi ciency: > 99.98% (standard NFX 44-011).
Uranine decontamination factor: > 5 000 (standard NFX 44-011).
Recommended fi nal pressure drop: 600 Pa.
Maximum airfl ow: Nominal airfl ow.
Temperature: static thermal resistance 120° C or 200° C maximum in continuous service depending on model.
Control: each fi lter is tested by unit for pressure drop and effi ciency in order to guarantee performances.
Guarantee: all the fi lters have been subject to typical tests made by the Atomic Energy Commission and are the object of a “Performance Guarantee” sheet.
Mounting systems: In tight lock casings or platforms.
Reference Model Dimension (WxHxD) mm
Uranine FR
Media area m² T°C Frame Sealant Gasket Airfl ow / Nominal P
m³/h / PaCalorifi c
potential MJUnit mass
kgUnit volume
m³
1501.26.00 Poly V-pack 450 600x130x202 > 5000 6.5 120 (1) 200( 2) S/Steel PVC Neoprene 450 / 250 26 6 0.02
1501.37.00 Poly V-pack 450 600x130x202 > 5000 6.5 120 (1) 200( 2) Galva steel PVC Neoprene 450 / 250 26 6 0.02
1501.40.00 Poly V-pack 450 600x130x202 > 5000 6.5 200 (1) Galva steel Mineral (3) Silicon 450 / 250 6.8 6 0.02
1503.37.00 Poly V-pack 1250 600x325x202 > 5000 16.8 120 (1) 200( 2) Galva steel PVC Neoprene 1250 / 250 65 11 0.04
1503.40.00 Poly V-pack 1250 600x325x202 > 5000 16.8 200 (1) Galva steel Mineral (3) Silicon 1250 / 250 17 11 0.04
1505.26.00 1505.53.00* Poly V-pack 1500 610x305x292 > 5000 20.5 120 (1)
200( 2) S/Steel PVC Neoprene 1500 / 250 67 14 0.05
1505.37.00 1505.55.00* Poly V-pack 1500 610x305x292 > 5000 20.5 120 (1)
200( 2) Galva steel PVC Neoprene 1500 / 250 67 14 0.05
1505.40.00 1505.54.00* Poly V-pack 1500 610x305x292 > 5000 20.5 200 (1) Galva steel Mineral (3) Silicon 1500 / 250 19 14 0.05
1506.17.00 Poly V-pack 3400 610x610x292 > 5000 40.5 200 (1) S/Steel Mineral (3) Silicon 3400 / 250 19 25 0.11
1506.22.00 Poly V-pack 3400 610x610x292 > 5000 40.5 200 (1) S/Steel Silicon Silicon 3400 / 250 25 0.11
1506.26.00 Poly V-pack 3400 610x610x292 > 5000 40.5 120 (1) 200( 2) S/Steel PVC Neoprene 3400 / 250 128 25 0.11
1506.37.00 Poly V-pack 3400 610x610x292 > 5000 40.5 120 (1) 200( 2) Galva steel PVC Neoprene 3400 / 250 128 25 0.11
1506.40.00 Poly V-pack 3400 610x610x292 > 5000 40.5 200 (1) Galva steel Mineral (3) Silicon 3400 / 250 35.5 25 0.11
* 1 handle on side 305 - (1) Temperature in continuous service - (2) Maximum admissible temperature for 1 hour - (3) can only be used for extraction air fi ltration.
Very High Efficiency
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com 25
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
Intr
oduc
tion
Med
ium
Effi
cien
cyH
igh
Effi c
ienc
yVe
ry H
igh
Effi c
ienc
yAd
sorp
tion
Casi
ngs
and
fi lte
rsfo
r co
ntai
nmen
t sys
tem
sCo
ntai
nmen
t equ
ipm
ent
Equi
pmen
t for
tem
pora
ry v
entil
atio
nAc
cess
orie
s
PTFE VHE POLY V-PACK FILTERSADVANTAGES• Individual verifi cation
• Traceability of each fi lter
• Guaranteed dimensional tolerance
Applications: Air conditioning, ventilation and air extraction in nuclear industries and buildings where hydrofl uoric acid is present in a gaseous state.
Type: VHE PTFE poly V-pack fi lter.
Media: PTFE membrane resistant to hydrofl uoric acid.
Separators: Hot-melt.
Sealant: Mineral (fi re classifi cation M0).
Frame: Stainless steel.
Gasket: Viton® lip seal.
Handle: 1 on side 610, parallel to V-packs.
Uranine effi ciency: > 99.98% (standard NFX 44-011).
Uranine decontamination factor: > 5 000 (standard NFX 44-011).
Recommended fi nal pressure drop: 600 Pa.
Maximum airfl ow: Nominal airfl ow.
Temperature: Static thermal resistance 70°C in continuous service.
Control: each fi lter is tested by unit for pressure drop and effi ciency in order to guarantee performances.
Mounting systems: In tight lock casings or platforms.
Reference Model Dimension (WxHxD) mm Uranine FR Media
area m² T°C Frame Sealant Gasket Airfl ow / Nominal P m³/h / Pa
Unit mass kg
Unit volume m³
1565.02.33 Poly V-pack 1500 610x305x292 > 5000 15 70 (1) S/Steel Mineral Viton 1500 / 250 13 0.05
1565.02.32* Poly V-pack 500 610x305x292 > 5000 15 70 (1) S/Steel Mineral Viton 1500 / 250 13 0.05
1560.02.32 Poly V-pack 3400 610x610x292 > 5000 35 70 (1) S/Steel Mineral Viton 3400 / 250 23 0.11
* 1 handle on side 305 - (1) Temperature in continuous service
Very High Efficiency
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com26
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
IntroductionM
edium Effi ciency
High Effi ciency
Very High Effi ciency
AdsorptionCasings and fi lters
for containment system
sContainm
ent equipment
Equipment for
temporary ventilation
Accessoires
CTHEN-APPROVED SOFILAIR FILTERS
ADVANTAGES• Accreditations by safety authority
• Guarantee and commitment of supplier
• High levels of ISO 9001quality and reliability
• Irradiation resistant
• The CTHEN range can be used instead of VHE fi lters that have already been installed without any modifi cation. However, pay attention to the rigidity of the clamping system, which must be suffi cient
The SOFILAIR CTHEN* range has been developed to meet the highest require-ments of the safety authorities under fi re emergency conditions. The fi lters that equip the fi nal level of fi ltration before emission into the atmosphere being regis-tered as “Important Safety Items” (decree dated 10 August 1984), their good beha-viour in an emergency situation is vital.
Camfi l Farr, by constantly listening to its clients and by basing itself on its unequal-led experience in nuclear fi ltration, has developed new products able to meet the requirements of the specifi cations esta-blished by CTHEN.* CTHEN = Technical Center for the Nuclear Equipment Accreditation.
CTHEN REINFORCED REQUIREMENTS
In relation to former requirements, the CTHEN specifi cation brings users an unarguable plus. The fi lter is dynamically tested and its aptitude to ensure that it is working is continuously controlled and, above all, in emergency conditions.
Actually, the fi lters are clogged (2000 Pa) during tests and undergo temperature cycles with large differences of between 70 and 300°C.
A DEVELOPMENT FOR VERY HIGH EFFICIENCY
The materials of the fi lters of the CTHEN range are highly stressed (major varia-tions in temperature, high pressure, im-mersion, fi re classifi cation, etc.).
The reliability of information is your concern: CTHEN provides its expertise and its authority for this, and Camfi l Farr pro-vides its experience and widely validated results.
A COMMITMENT TO SECURITY
The CTHEN accredited SOFILAIR range helps you in your quality approach.
As these fi lters are the fi nal barrier before emission into the atmosphere, the com-mitments of the supplier are important. Camfi l Farr also commits itself to the life-time of its products:• 7 years from the date of manufacture• 5 years in service under normal opera-
ting conditions.
SPECIFICATIONS ESTABLISHED BY CTHENCommon characteristics for very high performances:• Very High Effi ciency with uranine (0.15
µm) always controlled: FR > 5000.• High mechanical resistance.Very high effi ciency fi lters equipping the fi nal fi ltration barriers.CTHEN No. 93-030 value A3 categories of SOFILAIR CTHEN have been validated in line with this specifi ca-tion:• SOFILAIR CTHEN 70: to be used in
normal conditions up to 70°C.• SOFILAIR CTHEN 120: to be used up
to 120°C / 2 hours.• SOFILAIR CTHEN 200: to be used up
to 200°C / 2 hours.Resistance to the highest temperature level: 200°C or 230°C for 2 hours (depen-ding on model) dynamically and clog.Fire classifi cation minimum M1 for the va-rious parts and M2 for the gasket (accor-ding to NF P 92-507).Very high effi ciency fi lters for incinera-tors.CTHEN No. 96-116 value A• SOFILAIR CTHEN 230: to be used at
230°C / 2 hours.Very High Effi ciency fi lters are the fi nal barrier for fi ltering particles when proces-sing incinerator fumes.The inherent constraints of processing fumes are different to those related to fi re risk; standby and normal operating phases mean that fi lters are subject to conside-rable variations in temperature.For accreditation, the fi lter undergoes se-veral cycles with steps at 230°C and at 70°C.
Very High Efficiency
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com 27
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
Intr
oduc
tion
Med
ium
Effi
cien
cyH
igh
Effi c
ienc
yVe
ry H
igh
Effi c
ienc
yAd
sorp
tion
Casi
ngs
and
fi lte
rsfo
r co
ntai
nmen
t sys
tem
sCo
ntai
nmen
t equ
ipm
ent
Equi
pmen
t for
tem
pora
ry v
entil
atio
nAc
cess
orie
s
CTHEN-APPROVED SOFILAIR FILTERS
ADVANTAGES• Respects the cycle of CTHEN
specifi cation No. 93-030
Applications: Last fi ltration level of nuclear installations.
Type: CTHEN accredited VHE fi lter.
Media: Glass fi ber paper (fi re classifi cation M1). Resistance to Gamma irradiation according to standard ASME-AG1.
Separators: Glass fi ber thread.
Sealant: Polyurethane (70° C. Fire classifi cation M3) or mineral (120, 200 and 230° C/2h. Fire classifi cation M0).
Frame: Galvanized or stainless steel.
Gasket: Neoprene (70° C and 120° C/2h) or compact silicon (200 and 230° C/2h).
Handle: 1 on side 610 parallel to V-packs.
Uranine effi ciency: > 99.98% (standard NFX 44-011).
Uranine decontamination factor: > 5000 (standard NFX 44-011).
Recommended fi nal pressure drop: 600 Pa (maximum admissible 2000 Pa).
Maximum airfl ow: Nominal airfl ow.
Temperature: Dynamic thermal resistance 70°C in continuous service and 120, 200 and 230°C for 2h.
Control: each fi lter is tested by unit for pressure drop and effi ciency in order to guarantee performances.
Guarantee: All these fi lters have been subject to typical tests made by the Atomic Energy Commission and are the object of “performance guarantee” sheets, moreover they have been accredited by the CTHEN and CEA laboratory.
Assembly system: All types of tight lock casings, platforms and cages.
Reference Model Approval certifi cate
Dimensions (WxHxD) mm
Decontamination factor Uranine
Media area m²
Airfl ow / Nominal P
m³/h / PaT°C Frame Sealant Gasket Calorifi c
potential MJ
Unit mass
kg
Unit volume
m³APPROVED LAST FILTRATION BARRIER FILTERS (in accordance with CTHEN 93-030 val.0)
1565.08.10 SOFILAIR CTHEN 200 CTHEN n°067 610x305x292 >5000 16 1500 / 250 200/2h Galva Mineral Silicon 15.8 15 0.05
1565.08.11* SOFILAIR CTHEN 200 CTHEN n°067 610x305x292 >5000 16 1500 / 250 200/2h Galva Mineral Silicon 15.8 15 0.05
1565.12.10 SOFILAIR CTHEN 200 CTHEN n°068 610x305x292 >5000 16 1500 / 250 200/2h S/Steel Mineral Silicon 15.8 15 0.05
1565.12.11* SOFILAIR CTHEN 200 CTHEN n°068 610x305x292 >5000 16 1500 / 250 200/2h S/Steel Mineral Silicon 15.8 15 0.05
1563.08.10** SOFILAIR CTHEN 200 CTHEN n°066 600x325x202 >5000 15.6 1250 / 250 200/2h Galva Mineral Silicon 12.6 12 0.04
1563.12.10** SOFILAIR CTHEN 200 600x325x202 >5000 15.6 1250 / 250 200/2h S/Steel Mineral Silicon 12.6 12 0.04
1560.08.10 SOFILAIR CTHEN 200 CTHEN n°063 610x610x292 >5000 39.3 3400 / 250 200/2h Galva Mineral Silicon 28.7 25 0.11
1560.12.10 SOFILAIR CTHEN 200 CTHEN n°064 610x610x292 >5000 39.3 3400 / 250 200/2h S/Steel Mineral Silicon 28.7 25 0.11
APPROVED FILTERS FOR INCINERATORS (in accordance with CTHEN 96-116 val. 0)
1565.12.10 SOFILAIR CTHEN 230 n°065 610x305x29 >5000 16 1500 / 250 230/2h S/Steel Mineral Silicon 15.8 15 0.05
1565.12.11* SOFILAIR CTHEN 230 n°065 610x305x29 >5000 16 1500 / 250 230/2h S/Steel Mineral Silicon 15.8 15 0.05
* 1 handle on side 305 - ** no handle.
Very High Efficiency
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com28
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
IntroductionM
edium Effi ciency
High Effi ciency
Very High Effi ciency
AdsorptionCasings and fi lters
for containment system
sContainm
ent equipment
Equipment for
temporary ventilation
Accessoires
SETTLING TANK CANISTERS
ADVANTAGES• Large arresting capacity
• Mobile
• Irradiation resistant
• Can be adapted to industrial vacuum cleaner
Applications: In nuclear industries, together with vacuum cleaners, they are used for cleaning or occasional ventilation in controlled areas.
Type: Settling tank canister.
Media: Glass fi ber paper (fi re classifi cation M1). Resistance to Gamma irradiation according to standard ASME-AG1.
Separators: Glass fi ber thread.
Sealant: Polyurethane (fi re classifi cation M3).
Grid: Galvanized steel perforated sheet metal for internal protection and external ply.
Tank: Mild steel painted inside and outside.
Uranine effi ciency: > 99.98% (standard NFX 44-011) .
Uranine decontamination factor: > 5000 (standard NFX 44-011) .
Maximum airfl ow: Nominal airfl ow.
Temperature: 80° C maximum in continuous service (120° C at peak for 1 hour maximum).
Control: Oil mist 100%.
N.B.: For highly contaminating dust, a chain of several tanks connected together can be formed.
Reference ModelDimensions in mm Litre
capacity Uranine FR Media area m²
Airfl ow / Nominal P m³/h / Pa
Max admissible pressure Pa
Unit mass kg
Unit volume m³A B C D E
3261.01.10 10 l. settling tank 300 340 235 37 37 10 > 5000 2.4 150 / 700 35 000 2.9 0.02
3262.01.10 25 l. settling tank 370 410 330 60 60 25 > 5000 3.82 200 / 700 27 000 5.4 0.04
3263.05.10 40 l. settling tank 440 480 375 60 60 40 > 5000 3.82 200 / 700 20 000 6.4 0.06
3263.01.10 50 l. settling tank 540 580 375 60 60 50 > 5000 3.82 200 / 700 20 000 7.1 0.07
Very High Efficiency
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com 29
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
Intr
oduc
tion
Med
ium
Effi
cien
cyH
igh
Effi c
ienc
yVe
ry H
igh
Effi c
ienc
yAd
sorp
tion
Casi
ngs
and
fi lte
rsfo
r co
ntai
nmen
t sys
tem
sCo
ntai
nmen
t equ
ipm
ent
Equi
pmen
t for
tem
pora
ry v
entil
atio
nAc
cess
orie
s
SETTLING TANK CANISTERS
ADVANTAGES• Large arresting capacity
• Mobile
• Irradiation resistant
• Can be adapted to industrial vacuum cleaner
Applications: In nuclear industries, together with vacuum cleaners, they are used for cleaning or occasional ventilation in controlled areas.
Type: Settling tank canister.
Media: Glass fi ber paper (fi re classifi cation M1) Resistance to Gamma irradiation according to standard ASME-AG-1.
Separators: Glass fi ber thread.
Sealant: Polyurethane (fi re classifi cation M3).
Grid: Galvanized steel perforated sheet metal for internal and external ply.
Tank: Mild steel painted inside and outside.
Uranine effi ciency: > 99.98% (standard NFX 44-011).
Uranine decontamination factor: > 5000 (standard NFX 44-011).
Maximum airfl ow: Nominal airfl ow.
Temperature: 80° C maximum in continuous service (120° C at peak for 1 hour maximum).
Control: Oil mist 100%.
Reference Model Dimensions (ØxH) mm Litre capacity Decontamination
factor Uranine Media area m² Airfl ow / Nominal P m³/h / Pa
Max admissible pressure Pa
Unit mass kg
Unit volume m³
3264.03.01 Bidon fi ltrant 50 l 375x540 50 > 5000 4.75 200 / 700 20 000 8.6 0.08
Notes
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com30
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
IntroductionM
edium Effi ciency
High Effi ciency
Very High Effi ciency
AdsorptionCasings and fi lters
for containment system
sContainm
ent equipment
Equipment for
temporary ventilation
Accessoires
Adsorption
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com 31
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
Intr
oduc
tion
Med
ium
Effi
cien
cyH
igh
Effi c
ienc
yVe
ry H
igh
Effi c
ienc
yAd
sorp
tion
Casi
ngs
and
fi lte
rsfo
r co
ntai
nmen
t sys
tem
sCo
ntai
nmen
t equ
ipm
ent
Equi
pmen
t for
tem
pora
ry v
entil
atio
nAc
cess
orie
s
GENERAL POINTSTRAPPING HYDROGEN FLUORIDE
page 32
ACTICARB 4000
page 34
ACTIVATED CARBON V-PACKS
page 36
ACTICARB FOR TOXIC GASES
page 38
CONTENTS
RADIOIODINES TRAPPING
page 33
REINFORCED BARRELS
page 37
MOLECULAR FILTRATION QUESTIONNAIRE
page 39
ACTIVATED CARBONS
Activated carbons are generally prepared from carbon coming from coconut or coal. The thermal or chemical activation treatments that they are subject to give them an extraordinarily high surface area of about 1000 to 2500 m²/g. They come into the form of extruded granules or in the form of sieved grains. The pores of the activated carbon have diameters on the nanometre scale, that is to say the same level as the size of molecules.
Activated carbon traps molecules on the inside surface of its pores, under the effect of molecular attraction forces or Van der Waals forces. These attraction forces are all the more important as the molecules have high boiling points and molar mass. If these forces are very low, it is necessary to use impregnated activa-ted carbon that allows gaseous pollutants to be trapped by chemical reaction with the impregnating agent.
ADSORPTION EFFICIENCY AND LIFETIME OF ACTIVATED CARBON
The effi ciency of activated carbon decreases over time. This is explained by a reduction in available adsorption sites or by a drop in the quantity of impregnating agent.
The effi ciency of the adsorption of gas or the vapours diffused in the air depends on several factors, and in particular:
• On the type of pollutants.
• On the concentrations of pollutants: the higher the concentration of them, the lower the effi ciency or the lifetime
• On the quality of the activated carbon.
• On the granulometry of the activated carbon: the smaller the size of the granules or grains, the higher the effi ciency or the lifetime. Nevertheless, the granulometry has to be limited in practice by pressure drop criteria.
• On the contact time t between the gas and the adsorbent: t = V/Q(Volume of adsorbent/airfl ow).The longer the contact time, the better the effi ciency or the lifetime of the adsorbent.
• On the thickness of the adsorbent: the thicker the activated carbon bed, the higher the effi ciency or the lifetime. Nevertheless, this thickness has to be limited in practice by pressure drop criteria.
• On relative humidity: this parameter can positively or negatively infl uence the effi ciency or the lifetime of the activated carbon, depending on the physical and chemical mechanisms of the trapping of the pollutant by the adsorbent.
• On the temperature: the infl uence of this parameter can be more or less signifi -cant for the effi ciency or the lifetime of the activated carbon, depending on the physical and chemical mechanisms of trapping the pollutant by the adsorbent.
In the event of an accident in a nuclear reactor, the environ- ment and the people nearby are likely to be contaminated by released radioiodine. In order to limit the activity of the iodine emitted into the atmosphere as much as possible, ventilation systems for these premises are equipped with iodine adsorbers, such as ACTICARB or SOFILTRAD, installed on extraction circuits downstream of the adsorbent fi lters.
TRAPPING MECHANISMS
These radioiodines are in the form of ele-mentary iodine and organic compounds, methyl iodine in particular. Many scientifi c studies show that if elementary iodine can easily be trapped on ordinary activated carbon, trapping methyl iodine requires specifi c activated carbons generally impregnated with potassium iodide (KI) and/or triethylenediamine (TEDA). These impregnations allow reactions of the following types of trapping to be made:
• Isotopic exchange reaction
K 127 I + CH3 131 I K 131 Iads + CH3
127 I
• Nucleophile substitution reaction
This reaction leads to the formation of a quaternary diammonium salt, a non-vola-tile compound with a high boiling point.
OPTIMAL OPERATING CONDITIONS
• Contact time
The recommendations of the Guide for the Ventilation of Nuclear Installations (Atomic Energy Commission) set a minimum contact time of 0.25 seconds.
• Relative humidity
Relative humidity has a very important infl uence on effi ciency, especially with methyl iodine.
This is why an activated carbon with a decontamination factor ration ratio (DF) of 50 at 90% of relative humidity (RH), will have a DF over 10,000 at 40% RH for the same contact time of 0.2 seconds.
Each batch of adsorbent has its own effi ciency variation curve depending on relative humidity. The effi ciency extrapola-tions from one relative humidity to another cannot be made from this experimental curve and only give approximate values. (Example of a curve for a particular batch of carbon - see below).
Depending on the operating conditions, both normal and emergency ones, the relative humidity of the air extracted from the various premises of a plant can reach high values. That is why now in France, most air extraction circuits with iodine traps, have air heaters designed in such a way that the relative humidity does not exceed 40%. Consequently, iodine traps operate in the best possible conditions and have optimal effi ciency considering the adopted sizing criteria.
• Temperature
Activated carbons can only be validly used at temperatures that do not exceed 80°C, although their fl ash point is still higher than 250°C. For higher operating tempe-ratures, it is necessary to use molecular sieves or zeolites impregnated with silver.
ACTIVATED CARBON EFFICIENCY CONTROL
The activated carbon used by CAMFIL in its iodine traps is subject to a systematic effi ciency control with methyl iodine measured on a representative sample from each batch of activated carbon. This control is made by IRSN on its STEAM test bed. The validation criterion for batches of activated carbon is one DF > 80 to the ICH3 at 90% of RH. Moreover, Camfi l guarantees each of its ACTICARB 4000 cells by systematically controlling them on its leak detection test rig.
MOLECULAR FILTRATION QUESTIONNAIRE GENERAL
Project name
Date
Customer
Contact name
Phone number
Fax number
E-mail address
Comfort Clean Process Safety and Protection
Odours Atmospheric pollution
Process protection
Artefacts protection
Exhaust gas abatement
Employees protection
Application (tick off a box and describe the application)
Adsorption
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com32
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
IntroductionM
edium Effi ciency
High Effi ciency
Very High Effi ciency
AdsorptionCasings and fi lters
for containment system
sContainm
ent equipment
Equipment for
temporary ventilation
Accessoires
GENERAL POINTSACTIVATED CARBONS
Activated carbons are generally prepa-red from carbon coming from coconut or coal. The thermal or chemical activation treatments that they are subject to give them an extraordinarily high surface area of about 1000 to 2500 m²/g. They come into the form of extruded granules or in the form of sieved grains. The pores of the activated carbon have diameters on the nanometre scale, that is to say the same level as the size of molecules.
Activated carbon traps molecules on the inside surface of its pores, under the ef-fect of molecular attraction forces or Van der Waals forces. These attraction forces are all the more important as the mole-cules have high boiling points and molar mass. If these forces are very low, it is necessary to use impregnated activated carbon that allows gaseous pollutants to be trapped by chemical reaction with the impregnating agent.
ADSORPTION EFFICIENCY AND LIFETIME OF ACTIVATED CARBON
The effi ciency of activated carbon de-creases over time. This is explained by a reduction in available adsorption sites or by a drop in the quantity of impregnating agent.
The effi ciency of the adsorption of gas or the vapours diffused in the air depends on several factors, and in particular:
• On the type of pollutants.
• On the concentrations of pollutants: the higher the concentration of them, the lower the effi ciency or the lifetime
• On the quality of the activated carbon.
• On the granulometry of the activated carbon: the smaller the size of the granules or grains, the higher the effi ciency or the lifetime. Nevertheless, the granulometry has to be limited in practice by pressure drop criteria.
• On the contact time t between the gas and the adsorbent: t = V/Q(Volume of adsorbent/airfl ow).The longer the contact time, the better the effi ciency or the lifetime of the adsorbent.
• On the thickness of the adsorbent: the thicker the activated carbon bed, the higher the effi ciency or the lifetime. Nevertheless, this thickness has to be limited in practice by pressure drop cri-teria.
• On relative humidity: this parameter can positively or negatively infl uence the effi ciency or the lifetime of the activated carbon, depending on the physical and chemical mechanisms of the trapping of the pollutant by the adsorbent.
• On the temperature: the infl uence of this parameter can be more or less signifi -cant for the effi ciency or the lifetime of the activated carbon, depending on the physical and chemical mechanisms of trapping the pollutant by the adsorbent.
TRAPPING HYDROGEN FLUORIDEHydrogen fl uoride (HF) is a very toxic gas mainly produced by hydrolysis reactions of uraniferous compounds, in the uranium enrichment industry sector. As well as the high risk of chemical toxicity for people, this gas has the property of being very corrosive for many materials, in particular those based on steel and silicon.
Thus, CAMFIL has had to specifi cally adapt its range of products to provide lasting fi ltration solutions for extraction systems for gaseous effl uents containing hydrogen fl uoride.
RESISTANCE OF MATERIALS TO THE CORROSIVENESS OF HF
For applications in a corrosive environ-ment containing HF, CAMFIL recommends using:• Tight lock casings and buffers covered
with ECTFE (see page 74): this fl uoride polymer based coating has the property of being chemically inert to HF and thus stops the casing being corroded over time.
• VHE effi ciency in PTFE media (see page 25): classic VHE media made of glass fi ber should not be used where HF is present as it is very reactive with silicon, which is the main constituent of glass fi ber.
MECHANISM FOR HFTRAPPING
To trap gaseous HF, CAMFIL recommends using ACTICARB GA, a cell with activated carbon impregnated with KOH (potassium hydroxide) to trap acidic gases.
Actually, as hydrogen fl uoride is a very volatile acidic gas with a low boiling point, using classic activated carbons has no effect. Therefore, it is necessary to use activated carbon impregnated with a com-pound that chemically reacts with HF. As this is an acidic gas, it is therefore neces-sary to use an alkaline impregnating agent such as potassium hydroxide (KOH), that will react with the HF according to the fol-lowing acid-alkaline reaction:
H2O
HF(g) + KOH(s) = KF(s) + H2O(g)
The products of this reaction are potas-sium fl uoride, an inert salt remaining on the surface of the activated carbon, and steam. This reaction can only take place in the presence of water, which is needed to release the ions so that the acid-alkaline reaction can take place.
OPTIMAL OPERATING CONDITIONS
• Contact time
The contact time generally used for the design of HF traps in uranium enrichment factories varies between 0.29 and 0.5 s. The longer the contact time is, the longer the lifetime of the fi lters will be.
• Relative humidity
As opposed to radioiodine trapping, the effect of relative humidity is to promote the effi ciency of the HF trapping. Actually, water promotes the acid-alkaline reac-tion. Thus, the higher the hygrometry, the better the performance of the HF trap is. Nevertheless, it is recommended not to reach the water saturation point in order to not condense the water droplets within the activated carbon which would result in solubilising the impregnating agent and extracting it from the fi lter by airfl ow. Thus, CAMFIL recommends using HF traps with relative humidity between 30 and 90%.
Adsorption
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com 33
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
Intr
oduc
tion
Med
ium
Effi
cien
cyH
igh
Effi c
ienc
yVe
ry H
igh
Effi c
ienc
yAd
sorp
tion
Casi
ngs
and
fi lte
rsfo
r co
ntai
nmen
t sys
tem
sCo
ntai
nmen
t equ
ipm
ent
Equi
pmen
t for
tem
pora
ry v
entil
atio
nAc
cess
orie
s
In the event of an accident in a nuclear reactor, the environ- ment and the people nearby are likely to be contaminated by released radioiodine. In order to limit the activity of the iodine emitted into the at-mosphere as much as possible, ventilation systems for these premises are equipped with iodine adsorbers, such as ACTICARB or SOFILTRAD, installed on extraction cir-cuits downstream of the adsorbent fi lters.
TRAPPING MECHANISMS
These radioiodines are in the form of ele-mentary iodine and organic compounds, methyl iodine in particular. Many scientifi c studies show that if elementary iodine can easily be trapped on ordinary activated carbon, trapping methyl iodine requires specifi c activated carbons generally impre-gnated with potassium iodide (KI) and/or triethylenediamine (TEDA). These impre-gnations allow reactions of the following types of trapping to be made:
• Isotopic exchange reaction
K 127 I + CH3 131 I K 131 Iads + CH3
127 I
• Nucleophile substitution reaction
This reaction leads to the formation of a quaternary diammonium salt, a non-vola-tile compound with a high boiling point.
OPTIMAL OPERATING CONDITIONS
• Contact time
The recommendations of the Guide for the Ventilation of Nuclear Installations (Atomic Energy Commission) set a mini-mum contact time of 0.25 seconds.
• Relative humidity
Relative humidity has a very important infl uence on effi ciency, especially with methyl iodine.
This is why an activated carbon with a decontamination factor ration ratio (DF) of 50 at 90% of relative humidity (RH), will have a DF over 10,000 at 40% RH for the same contact time of 0.2 seconds.
Each batch of adsorbent has its own effi -ciency variation curve depending on rela-tive humidity. The effi ciency extrapolations from one relative humidity to another cannot be made from this experimental curve and only give approximate values. (Example of a curve for a particular batch of carbon - see below).
Depending on the operating conditions, both normal and emergency ones, the rela-tive humidity of the air extracted from the various premises of a plant can reach high values. That is why now in France, most air extraction circuits with iodine traps, have air heaters designed in such a way that the relative humidity does not exceed 40%. Consequently, iodine traps operate in the best possible conditions and have optimal effi ciency considering the adopted sizing criteria.
• Temperature
Activated carbons can only be validly used at temperatures that do not exceed 80°C, although their fl ash point is still higher than 250°C. For higher operating tempe-ratures, it is necessary to use molecular sieves or zeolites impregnated with silver.
ACTIVATED CARBON EFFICIENCY CONTROL
The activated carbon used by CAMFIL in its iodine traps is subject to a systema-tic effi ciency control with methyl iodine measured on a representative sample from each batch of activated carbon. This control is made by IRSN on its STEAM test bed. The validation criterion for batches of activated carbon is one DF > 80 to the ICH3 at 90% of RH. Moreover, Camfi l gua-rantees each of its ACTICARB 4000 cells by systematically controlling them on its leak detection test rig.
RADIOIODINES TRAPPING
Adsorption
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com34
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
IntroductionM
edium Effi ciency
High Effi ciency
Very High Effi ciency
AdsorptionCasings and fi lters
for containment system
sContainm
ent equipment
Equipment for
temporary ventilation
Accessoires
ACTICARB 4000
ADVANTAGES• Individual test certifi cate supplied with each fi lter
• High performance of installations thanks to the high effi ciency of the product
• Optimal volume of activated carbon for a maximum lifetime
• Proven product, the factory controlled characteristics of which are maintained after handling and transportation
• Time saving during work thanks to certifi cate guarantee of individual testing
• Guarantee of a minimum leak rate
Acticarb 4000 uses selected and control-led activated carbon to offer all the essen-tial correct operating, reliability and safety guarantees, needed in particular in the nu-clear fi eld. CAMFIL FARR guarantees that you systematically have IRSN controlled batches of activated carbon for trapping radio-iodines.
CAMFIL FARR is the only manufacturer to offer you these guarantees for over thirty years, as our formula criteria leave no room for error.
ACTICARB 4000 from CAMFIL FARR is:• High effi ciency: initial decontamination
factor over 4000 at ICH3 (for a mini-mum contact time of 0.2s and relative humidity lower than 40%).
• An additional guarantee: the individual controlling of the leak rate, with cyclo-hexane concentration measurements upstream and downstream of the fi lter on a fi lter test rig.
• Product traceability thanks to our ISO 9001 certifi cation.
ACTICARB: LEAKS CONTROLS
Its performance and its assets• Selection of activated carbon.• Complete traceability.
Implementation of activated carbon• Settling by calibrated vibrations.• Dust extraction.
Complete controls• Pressure drop.• Leak detection.
Designed for effi ciency• A thick carbon layer.• Settlement maintained by compression
mattress.• Rigid frame to maintain product charac-
teristics.
WHY IS THIS CONTROL MADE?
High guaranteed effi ciency
Despite a perfectly mastered manufactu-ring procedure, the decontamination fac-tor of 4000 at ICH3 cannot be guaranteed without controlling that it matches up to this requirement: leak detection.
Test certifi cate
The test certifi cate provided with each fi lter ensures you that all the parameters have been controlled and that, in case of effi ciency defect on your installation, the leak cannot come from the fi lter.
Commitment to quality
100% controlled ACTICARB 4000 fi lters help you in your quality approach.
Adsorption
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com 35
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
Intr
oduc
tion
Med
ium
Effi
cien
cyH
igh
Effi c
ienc
yVe
ry H
igh
Effi c
ienc
yAd
sorp
tion
Casi
ngs
and
fi lte
rsfo
r co
ntai
nmen
t sys
tem
sCo
ntai
nmen
t equ
ipm
ent
Equi
pmen
t for
tem
pora
ry v
entil
atio
nAc
cess
orie
s
ACTICARB 4000
ADVANTAGES• Individual test certifi cate
provided with each fi lter
• Installation performance thanks to high effi ciency
• Optimal volume of activated carbon for a maximum lifetime
• Proven product, the factory controlled characteristics of which are maintained after handling and transportation
Applications: Radioiodines trapping (elementary iodine and methyl iodide), nuclear energy production industries, radio-isotopic manu-facturing industries, radio-isotope users (nuclear medicine), etc.
Type: Activated carbon fi lter.
Media: KI and TEDA impregnated activated carbon for the trapping of iodine with carbon effi ciency control at ICH3 by IRSN (Institute of Radioprotection and Nuclear Safety).
Charcoal bed: layer thickness 50mm, vibrated and settled by compression mattress eliminating any risk of leak over time.
Frame: Painted mild steel or X2CrNi 18-9 stainless steel depending on model.
Gasket: Semi-ring Ø 15 mm, in one single piece, made of neoprene foam.
Decontamination factor: FR > 4000 at ICH3 for a contact time of 0.2s at 40% relative humidity.
Maximum leak rate: 2.5 x 10-4.
Control: Leak and pressure drop control at 100%.
Assembly system: Tight lock casings and platforms.
OPTIMAL OPERATING CONDITIONS
Temperature: lower than 80°C.
Relative humidity: < 40%.
Reference Model Dimensions (WxHxD) mm
Carbon volume litres
ICH3 fi ltration
coeff.
Carbon impregnation
Max. Airfl ow / P (±20%) m³/h*/ Pa Frame Calorifi c
potential MJ
Approx. unit mass
kg
Unit volume
m³
1606.36.00 Acticarb 4000 610x610x292 65 > 4000 KI and TEDA 1200 / 300 Painted mild steel 1400 82 0.11
1606.37.00 Acticarb 4000 610x610x292 65 > 4000 KI and TEDA 1200 / 300 Stainless steel 1400 82 0.11
1625.36.00 Acticarb 4000 305x610x292 32.5 > 4000 KI and TEDA 600 / 300 Painted mild steel 700 45 0.05
1625.37.00 Acticarb 4000 305x610x292 32.5 > 4000 KI and TEDA 600 / 300 Stainless steel 700 45 0.05
* to obtain a contact time of 0.2 s.
Adsorption
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com36
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
IntroductionM
edium Effi ciency
High Effi ciency
Very High Effi ciency
AdsorptionCasings and fi lters
for containment system
sContainm
ent equipment
Equipment for
temporary ventilation
Accessoires
ACTIVATED CARBON V-PACKS
ADVANTAGES• Appropriated to small airfl ows
Applications: Radioiodines trapping (elementary iodine and methyl iodide), nuclear energy production industries, radio-isotopic manu-facturing industries, radio-isotope users (nuclear medicine), etc.
Type: Activated carbon V-pack.
Media: KI and TEDA impregnated activated carbon for the trapping of iodine with carbon effi ciency control at l’ICH3 by IRSN (Institute of Radioprotection and Nuclear Safety).
Charcoal bed: Layer thickness 50mm, kept settled by compression mattress eliminating any risk of leak.
Frame: Painted mild steel or X2CrNi 18-9 stainless steel depending on model.
Gasket: Semi-ring Ø 15 mm, in one single piece, made of neoprene foam, depending on model.
Maximum airfl ow: Nominal airfl ow.
Control: Filter weighing at 100%.
Assembly system: BSS type metal casing or tight lock casing.
Assembly: For tight lock casings, the V-packs have to be fi tted with a neoprene semi-ring gasket.
OPTIMAL OPERATING CONDITIONS
Temperature: lower than 80°C.
Relative humidity: < 40%.
Reference Model Dimensions (WxHxD) mm
Carbon volume litres
ICH3 fi ltration
coeff.
Carbon impregnation
Nominal airfl ow / P (±20%) m³/h*/ Pa Frame Gasket
Approx. unit mass
kg
Unit volume
m³
3604.23.00 Mild steel V-pack 600x130x202 11 > 1000 KI and TEDA 190 / 300 Painted mild steel none 15 0.02
3604.92.00 Mild steel V-pack 600x130x202 11 > 1000 KI andTEDA 190 / 300 Painted mild steelt Neoprene 15 0.02
3604.33.00 Stainless steel V-pack 600x130x202 11 > 1000 KI and TEDA 190 / 300 Stainless steel none 15 0.02
3604.94.00 Stainless steel V-pack 600x130x202 11 > 1000 KI and TEDA 190 / 300 Stainless steel Neoprene 15 0.02
* to obtain a contact time of 0.2 s.
Adsorption
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com 37
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
Intr
oduc
tion
Med
ium
Effi
cien
cyH
igh
Effi c
ienc
yVe
ry H
igh
Effi c
ienc
yAd
sorp
tion
Casi
ngs
and
fi lte
rsfo
r co
ntai
nmen
t sys
tem
sCo
ntai
nmen
t equ
ipm
ent
Equi
pmen
t for
tem
pora
ry v
entil
atio
nAc
cess
orie
s
REINFORCED BARRELSWITH ACTIVATED CARBON FOR TRAPPING RADIO-IODES
ADVANTAGES• Reinforced metal drum packing
• Can be adapted to group loading and unloading connections
• Secured tank opening
Applications: loading and unloading of carbon by pneumatic method for rechargeable iodine traps and without contact with the conta-minated carbon.
Type: reinforced metal drum for activated carbon.
Media: KI and TEDA impregnated activated carbon for the trapping of iodine with carbon effi ciency control at ICH3 by IRSN (Institute of Radioprotection and Nuclear Safety).
Granulometry: 1.19 to 2.38 mm.
ASTM hardness: > 97 %.
Packaging:
Metal cast with removable cover fi xed by strapping and locked.
Maximum admissible depression: 3500 daPa.
Sealed drum with vent stopper.
Plastic cover with collar.
CONTROLS: on each manufacturing batch of activated carbon (offi cial certifi cate on sample).
Supplier controls: KI content, granulometry, water content, hardness, pressure drop.
IRSN Control: ICH3 effi ciency at 90 % RH.
Reference Model Dimensions (ØxH) mm
Actived carbon mass kg
ICH3 fi ltration coeff.* 90% HR
Carbon impregnation
Approx. unit mass kg
Unit volume m³
1600.21.00 Actived carbon barrel 600x910 100 CE > 80 KI and TEDA 130 0.26
* at 25 cm/s on one 5 cm layer of activated carbon (IRSN control).
Adsorption
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com38
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
IntroductionM
edium Effi ciency
High Effi ciency
Very High Effi ciency
AdsorptionCasings and fi lters
for containment system
sContainm
ent equipment
Equipment for
temporary ventilation
Accessoires
ACTICARB FOR TOXIC GASES
ADVANTAGES• High trapping effi ciency
• Optimal volume of activated carbon for a maximum lifetime and good adsorption ability
Applications: Toxic gases trapping (acids, alkalines, organic gases, mercury).
Type: Activated carbon fi lter.
Media: Activated carbon with specifi c impregnation depending on type of gas to be trapped.
Charcoal bed: Layer thickness 50 vibrated and settled by compression mattress eliminating any risk of leak over time.
Frame: Painted mild steel or X2CrNi 18-9 stainless steel depending on model.
Gasket: Semi-ring Ø 1/2 mm in one single piece made of neoprene foam.
Control: Pressure drop control at 100%
Assembly system: Tight lock casings and platforms.
Reference Model Dimensions (WxHxD) mm
Carbon volume litres
Gas or vapours to trapActived carbon
type
Carbon impregnation
Max. Airfl ow / P (±20%)
m³/h / PaFrame Calorifi c
potential MJ
Approx. unit mass
kg
Unit volume
m³
1606.94.02 Acticarb GA 610x610x292 65 Acids (HF, HCl, H2S, SO2…) CEX002A3 KOH 1200 / 200 Painted mild steel 1400 82 0.11
1606.80.02 Acticarb GA 610x610x292 65 Acids (HF, HCl, H2S, SO2…) CEX002A3 KOH 1200 / 200 Stainless steel 1400 82 0.11
1625.72.03 Acticarb GA 305x610x292 32.5 Acids (HF, HCl, H2S, SO2…) CEX002A3 KOH 600 / 200 Painted mild steel 700 45 0.05
1625.80.02 Acticarb GA 305x610x292 32.5 Acids (HF, HCl, H2S, SO2…) CEX002A3 KOH 600 / 200 Stainless steel 700 45 0.05
1606.75.05 Acticarb GB 610x610x292 65 Bases (ammonia and amine) CEX002B1 Acid 1200 / 200 Painted mild steel 1400 82 0.11
1606.75.04 Acticarb GB 610x610x292 65 Bases (ammonia and amine) CEX002B1 Acid 1200 / 200 Stainless steel 1400 82 0.11
1625.72.04 Acticarb GB 305x610x292 32.5 Bases (ammonia and amine) CEX002B1 Acid 600 / 200 Painted mild steel 700 45 0.05
1625.72.05 Acticarb GB 305x610x292 32.5 Bases (ammonia and amine) CEX002B1 Acid 600 / 200 Stainless steel 700 45 0.05
1606.85.01 Acticarb HG 610x610x292 65 Mercury LGS816J4 Iodized derivatives 800 / 180 Painted mild steel 1400 82 0.11
1625.85.01 Acticarb HG 305x610x292 32.5 Mercury LGS816J4 Iodized derivatives 400 / 180 Painted mild steel 700 45 0.05
1606.70.00 Acticarb GO 610x610x292 65 Organic compounds LGS048 none 1800 / 300 Painted mild steel 1400 82 0.11
1625.00.02 Acticarb GO 305x610x292 32.5 Organic compounds LGS048 none 900 / 300 Painted mild steel 700 45 0.05
LIMIT OPERATING CONDITIONS
Reference Minimum temperature
Maximum temperature
Minimum relative humidity
Maximum relative humidity
1606.94.02
10°C 80°C 30% 90%
1606.80.021625.72.031625.80.021606.75.051606.75.041625.72.041625.72.051606.85.011625.85.011606.70.00 10°C 40°C 10% 70%1625.00.02
Adsorption
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com 39
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
Intr
oduc
tion
Med
ium
Effi
cien
cyH
igh
Effi c
ienc
yVe
ry H
igh
Effi c
ienc
yAd
sorp
tion
Casi
ngs
and
fi lte
rsfo
r co
ntai
nmen
t sys
tem
sCo
ntai
nmen
t equ
ipm
ent
Equi
pmen
t for
tem
pora
ry v
entil
atio
nAc
cess
orie
s
Page 1 of 2 Camfil Farr – Private and confidential
MOLECULAR FILTRATION QUESTIONNAIRE GENERAL
Project name
Date
Customer
Contact name
Phone number
Fax number
E-mail address
Comfort Clean Process Safety and Protection
Odours Atmospheric pollution
Process protection
Artefacts protection
Exhaust gas abatement
Employees protection
Application (tick off a box and describe the application)
Describe the process if necessary
What is the progress of project? (tick of f a box)
Feasibility study Estimate
budget Performance in progress
New or existing installation?
New installation Existing
installation
Indoor duct Outdoor Making air unit Recycled air
Atmospheric exhaust Fumehood cupboard Other
Where is positioned the filtration system?
MOLECULAR FILTRATION QUESTIONNAIRE PAGE 1/2
Adsorption
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com40
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
IntroductionM
edium Effi ciency
High Effi ciency
Very High Effi ciency
AdsorptionCasings and fi lters
for containment system
sContainm
ent equipment
Equipment for
temporary ventilation
Accessoires
Page 2 of 2 Camfil Farr – Private and confidential
Required dimensions?
What are the final user’s goals?
ABOUT THE PROCESS Mean Minimum Maximum Unities (tick off a case or specify another unity)
cfm m3/s m3/hr kg/hr Air flow rate
Temperature deg.C deg.F
Relative humidity %
Concentration Main contaminants Mean Minimum Maximum ppb ppm mg/m3 g/hr
Working time hours/day days/year
Non working periods hours/day days/year
Available differential pressure (Pa)
Any particle filter already installed?
Any housing already installed?
OTHER INFORMATION ___________________________________________________________________________ ___________________________________________________________________________ ___________________________________________________________________________ ___________________________________________________________________________ ___________________________________________________________________________
MOLECULAR FILTRATION QUESTIONNAIRE PAGE 2/2
Casings and filters for containment systems
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com 41
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
Intr
oduc
tion
Med
ium
Effi
cien
cyH
igh
Effi c
ienc
yVe
ry H
igh
Effi c
ienc
yAd
sorp
tion
Casi
ngs
and
fi lte
rsfo
r co
ntai
nmen
t sys
tem
sCo
ntai
nmen
t equ
ipm
ent
Equi
pmen
t for
tem
pora
ry v
entil
atio
nAc
cess
orie
s
FILTERS FOR LEAKTIGHTENCLOSURES
page 57
STAINLESS STEEL CASINGS70 m³/h
page 53
CASINGS FOR RADIOACTIVE CELLS
page 58
PUSH-PUSHFILTERSANDSYSTEMS
page 55
METAL CASE VHE FILTERS30-70 m³/h
page 46
STAINLESS STEEL CASINGS300 m³/h
page 54
BSS DUCT CASINGS
page 59
PVC CASE VHE FILTERS 30 m³/h et 50 m³/h
page 45
CONTENTS
PVC CASE VHE FILTERS 5 m³/h
page 43
PVC CASE VHE FILTERS 20-30-50m³/h
page 44
GENERAL POINTS
page 42
METAL CASE VHE FILTERS300 m³/h
page 47p
VHE FILTERS 50 m³/h
page 48
ACTIVATED CARBON FILTERS
page 49
SCHEMATIC DIAGRAMFOR STAINLESS STEEL CASING
page 50
STAINLESS STEEL CASINGS5 m³/h
page 51
STAINLESS STEEL CASINGS30 m³/h
page 52
PRINCIPLES
CONTAINMENT enclosures: glove boxes and cells for the remote handling of radioactive products, are subject to particular ventilation aimed at ensuring the safety of the personnel and, in certain cases, protecting the products handled. We can differentiate between three types of ventilation networks:
Open network
A network into which we allow, in the enclosure, local ambient air that we then emit outside after fi ltration and possibly trapping toxic products.
Semi-open network
A network in which we ventilate the enclosure by a gas or a gaseous mix that we then emit outside after fi ltration and possibly trapping toxic products.
Closed network
A network in which ventilation is made by recycling a gas or a gaseous mixture which is continuously fi ltered and purifi ed.
The majority of CONTAINMENT enclo-sures are ventilated by an open circuit by ambient air sweeping. As, in general, it is necessary to protect personnel from contamination, the enclosure is held in depression of 100 to 500 Pa in relation to the premises.
To ensure correct sweeping and maintain the desired depression, the renewal rate is generally set at 10 volumes per hour.
The fi ltration of an enclosure, for example a category 2 glove box in accordance with AFNOR M 62.200 standard or ISO 10648-2 with a regulation system for extraction, must normally be equipped as shown opposite.
FILTRATION DEVICES ON CONTAINMENT ENCLOSURES
The aim of admission and extraction systems is to form a barrier against contamination during normal operating and if ventilation is stopped.
Admission fi lters
VHE admission fi lters avoid introducing dust into the enclosure coming from the aspirated air into the premises and slow down the clogging of extraction fi lters.
They have to be designed for the normal airfl ow of the enclosure and enclosure depression equal to the pressure drop of the new fi lter + a clogging reserve usually of between 100 and 200 Pa.
Extraction fi lters
VHE extraction fi lters are intended to stop contamination and generally toxic products in a particular state.
They have to be designed depending on the airfl ow to be processed in normal operating as well as the airfl ow to be extracted in case of accident, pulling off of a glove, for example. To determine the manometric height needed for aspiration, it is necessary to take into account a clog-ging reserve of about 250 Pa for the fi rst stage, as well as all the singular pressure drops for the network.
It should be noted that pressure drops given in technical sheets relating to fi lters correspond to the fi ltering item alone and it is necessary to add possible singular pressure drops due to assembly: casing, casing etc.
If radioiodines have been emitted into the enclosure, an activated carbon fi lter should be planned “downstream” of the VHE fi lters.
CONTROLS DURING OPERATING
It is strongly recommended, from a safety point of view, to carry out the following controls:• depression of the enclosure in relation
to the premises,• airfl ow extracted using an airfl ow meter
installed on the extraction device or by measuring the pressure drop in the second stage of extraction fi lters, which are never clogged,
• clogging control of the fi rst barrier fi lters on admission and extraction.
Casings and filters for containment systems
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com42
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
IntroductionM
edium Effi ciency
High Effi ciency
Very High Effi ciency
AdsorptionCasings and fi lters
for containment system
sContainm
ent equipment
Equipment for
temporary ventilation
Accessoires
PRINCIPLES
CONTAINMENT enclosures: glove boxes and cells for the remote handling of ra-dioactive products, are subject to particu-lar ventilation aimed at ensuring the safety of the personnel and, in certain cases, protecting the products handled. We can differentiate between three types of venti-lation networks:
Open network
A network into which we allow, in the enclosure, local ambient air that we then emit outside after fi ltration and possibly trapping toxic products.
Semi-open network
A network in which we ventilate the enclo-sure by a gas or a gaseous mix that we then emit outside after fi ltration and pos-sibly trapping toxic products.
Closed network
A network in which ventilation is made by recycling a gas or a gaseous mixture which is continuously fi ltered and purifi ed.
The majority of CONTAINMENT enclo-sures are ventilated by an open circuit by ambient air sweeping. As, in general, it is necessary to protect personnel from conta-mination, the enclosure is held in depres-sion of 100 to 500 Pa in relation to the premises.
To ensure correct sweeping and maintain the desired depression, the renewal rate is generally set at 10 volumes per hour.
The fi ltration of an enclosure, for example a category 2 glove box in accordance with AFNOR M 62.200 standard or ISO 10648-2 with a regulation system for extraction, must normally be equipped as shown opposite.
FILTRATION DEVICES ON CONTAINMENT ENCLOSURES
The aim of admission and extraction sys-tems is to form a barrier against contami-nation during normal operating and if ven-tilation is stopped.
Admission fi lters
VHE admission fi lters avoid introducing dust into the enclosure coming from the aspirated air into the premises and slow down the clogging of extraction fi lters.
They have to be designed for the normal airfl ow of the enclosure and enclosure de-pression equal to the pressure drop of the new fi lter + a clogging reserve usually of between 100 and 200 Pa.
Extraction fi lters
VHE extraction fi lters are intended to stop contamination and generally toxic pro-ducts in a particular state.
They have to be designed depending on the airfl ow to be processed in normal ope-rating as well as the airfl ow to be extracted in case of accident, pulling off of a glove, for example. To determine the manometric height needed for aspiration, it is necessa-ry to take into account a clogging reserve of about 250 Pa for the fi rst stage, as well as all the singular pressure drops for the network.
It should be noted that pressure drops given in technical sheets relating to fi lters correspond to the fi ltering item alone and it is necessary to add possible singular pressure drops due to assembly: casing, casing etc.
If radioiodines have been emitted into the enclosure, an activated carbon fi lter should be planned “downstream” of the VHE fi lters.
CONTROLS DURING OPERATING
It is strongly recommended, from a safety point of view, to carry out the following controls:• depression of the enclosure in relation to
the premises,• airfl ow extracted using an airfl ow meter
installed on the extraction device or by measuring the pressure drop in the second stage of extraction fi lters, which are never clogged,
• clogging control of the fi rst barrier fi lters on admission and extraction.
RENEWING CLOGGED FILTERS
As the previous controls are systematically carried out , it is necessary to replace:• the admission fi lter when, with regu-
lating valve (4) completely open, the depression exceeds the set point, the admission airfl ow having a lower value than the nominal value;
• the extraction fi lter when, regulating valve (4) being completely open, the depression in the enclosure is lower than the set point, the extraction airfl ow having a value lower than the nominal value.
On enclosures fi tted with two fi lters in se-ries for extraction and for admission, only the fi lter placed downstream is clogged.
GENERAL POINTS
General extraction network
Casings and filters for containment systems
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com 43
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
Intr
oduc
tion
Med
ium
Effi
cien
cyH
igh
Effi c
ienc
yVe
ry H
igh
Effi c
ienc
yAd
sorp
tion
Casi
ngs
and
fi lte
rsfo
r co
ntai
nmen
t sys
tem
sCo
ntai
nmen
t equ
ipm
ent
Equi
pmen
t for
tem
pora
ry v
entil
atio
nAc
cess
orie
s
PVC CASE VHE FILTERS 5 m3/h
ADVANTAGES• Can be adapted to small airfl ows
• Space saving
• Irradiation resistant
Applications: Arresting dust, bacteria and aerosols; manometer protection; safety valve exhaust for: nuclear and pharmaceutical indus-tries and hospitals.
Type: Filters for glove boxes and containment enclosures.
Media: Glass fi ber paper (fi re classifi cation M1). Gamma irradiation resistance according to standard ASME-AG1.
Separators: Glass fi ber thread.
Sealant: Polyurethane (fi re classifi cation M3).
Case: Polyvinyl chloride (PVC).
Gasket: Neoprene.
Uranine effi ciency: >99.98% (standard NFX 44-011).
Recommended fi nal pressure drop: 600 Pa.
Admissible maximum pressure drop: 1000 Pa.
Uranine decontamination factor: > 5000 (standard NFX 44-011).
Maximum airfl ow: Nominal airfl ow.
Temperature: 70° C maximum in continuous service.
Control: Leak detection 100% of products.
Mounting systems: Stainless steel casing.
Reference Model Dimensions (ØxH) mm
Uranine effi ciency Uranine FR Media area
m²Airfl ow / P
m³/h / Pa Thread gasket GasketCalorifi c potential
MJ
Unit mass
kg
Unit volume
m³
3205.11.00 * 5 m3/h fi lter with open casingDelivered with ring and gasket 92x35 At 5 m³/h
> 99.98%At 5 m³/h
FR > 5000 0.075 / 2203 / 1301 / 60
See special details
Neoprene 4mm thick 1.9 0.125 0.0003
* you must use a fi lter fi tted with a cover (ref. 6202.92.81) for assembly in casing (not supplied with the fi lter).
Casings and filters for containment systems
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com44
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
IntroductionM
edium Effi ciency
High Effi ciency
Very High Effi ciency
AdsorptionCasings and fi lters
for containment system
sContainm
ent equipment
Equipment for
temporary ventilation
Accessoires
PVC CASE VHE FILTERS 20-30-50 m3/h
ADVANTAGES• Can be adapted to small airfl ows
• Space saving
• Irradiation resistant
• Prehension cross bar from model 50m³/h
• Peripheral opening: safety feature for passage of airfl ow
Reference Model Dimensions (ØxH) mm
Uranine effi ciency Uranine FR Media
area m²Airfl ow / P
m³/h / Pa Thread gasket GasketCalorifi c potential
MJ
Unit mass
kg
Unit volume
m³
3211.01.00 20 m3/h fi lter with open casing 140x130 At 20 m³/h >99.98%
At 20 m³/h FR > 5000 0.49
20 / 210 15 / 150 10 / 70
Ø 34 see special detail
Neoprene 4mm thick 0.5 0.002
3201.01.00 30 m3/h fi lter with open casing 140x130 At 30 m³/h >99.98%
At 30 m³/h FR > 5000 0.49
30 / 180 20 / 110 10 / 50
Ø 61.62.5 thread
Neoprene 4mm thick 15 0.56 0.002
3201.01.01 * 30 m3/h fi lter with peripheral openings 140x130 At 30 m³/h
>99.98%At 30 m³/h FR > 5000 0.49
30 / 180 20 / 110 10 / 50
Ø 61.62.5 thread
Neoprene 4mm thick 0.5 0.002
3202.04.00 50 m3/h fi lter with open casingPrehension cross bar 160x173 At 50 m³/h
>99.98%At 50 m³/h FR > 5000 0.75
50 / 200 30 / 110 20 / 70
Ø 61.62.5 thread
Neoprene 4mm thick 16.6 0.9 0.0035
3202.04.01*50 m3/h fi lter with peripheral
openingsPrehension cross bar
160x173 At 50 m³/h >99.98%
At 50 m³/h FR > 5000 0.75
50 / 200 30 / 110 20 / 70
Ø 61.62.5 thread
Neoprene 4mm thick 0.8 0.0035
* for assembly in casing.
Prehension cross bar
Open casing
Peripheral opening
Open casing
Applications: Arresting dust, bacteria and aerosols; manometer protection; safety valve exhaust for: nuclear and pharmaceutical industries and hospital establishments.
Type: Filters for glove boxes and containment enclosures.
Media: Glass fi ber paper (fi re classifi cation M1). Gamma irradiation resistance according to standard ASME-AG1.
Separators: Glass fi ber thread.
Sealant: Polyurethane (fi re classifi cation M3).
Case: Polyvinyl chloride (PVC).
Gasket: Neoprene.
Uranine effi ciency: >99.98% (standard NFX 44-011).
Recommended fi nal pressure drop: 600 Pa.
Admissible maximum pressure drop: 1000 Pa.
Uranine decontamination factor: > 5000 (standard NFX 44-011).
Maximum airfl ow: Nominal airfl ow.
Temperature: 70° C maximum in continuous service.
Control: Leak detection 100% of products.
Mounting systems: Stainless steel casing.
Casings and filters for containment systems
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com 45
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
Intr
oduc
tion
Med
ium
Effi
cien
cyH
igh
Effi c
ienc
yVe
ry H
igh
Effi c
ienc
yAd
sorp
tion
Casi
ngs
and
fi lte
rsfo
r co
ntai
nmen
t sys
tem
sCo
ntai
nmen
t equ
ipm
ent
Equi
pmen
t for
tem
pora
ry v
entil
atio
nAc
cess
orie
s
PVC CASE VHE FILTERS 30 m3/h et 50 m3/h
ADVANTAGES• Filter standing peracetic acid
• Fluted adaptor
Reference Model Dimensions (ØxH) mm
Uranine effi ciency Uranine FR Media
area m2Airfl ow / P
m³/h / PaThread gasket Gasket
Calorifi c potential
MJ
Unit mass
kg
Unit volume
m³
3203.01.00 30 m3/h fi lter with closed casing 140x190 At 30 m³/h >99.98%
At 30 m³/h FR > 5000 0.49
30 / 200 20 / 120 10 / 40
Ø 61.62.5 thread
Neoprene 5mm thick 0.745 0.003
3204.01.00 50 m3/h fi lter with closed casing 160x218 At 50 m³/h >99.98%
At 50 m³/h FR > 5000 0.75
50 / 250 30 / 130 20 / 80
Ø 61.62.5 thread
Neoprene 5mm thick 18 1.2 0.0045
Applications: Arresting dust, bacteria and aerosols; manometer protection; safety valve exhaust for: nuclear and pharmaceutical indus-tries and hospital establishments.
Type: Filters for glove boxes and containment enclosures.
Media: Glass fi ber paper (fi re classifi cation M1). Gamma irradiation resistance according to standard ASME-AG1.
Separators: Glass fi ber thread.
Sealant: Polyurethane (fi re classifi cation M3).
Case: Polyvinyl chloride (PVC).
Gasket: Neoprene.
Uranine effi ciency: >99.98% (standard NFX 44-011).
Recommended fi nal pressure drop: 600 Pa.
Admissible maximum pressure drop: 1000 Pa.
Uranine decontamination factor: > 5000 (standard NFX 44-011).
Maximum airfl ow: Nominal airfl ow.
Temperature: 70° C maximum in continuous service.
Control: Leak detection 100% of products.
Mounting systems: Stainless steel casing.
Casings and filters for containment systems
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com46
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
IntroductionM
edium Effi ciency
High Effi ciency
Very High Effi ciency
AdsorptionCasings and fi lters
for containment system
sContainm
ent equipment
Equipment for
temporary ventilation
Accessoires
METAL CASE VHE FILTERS 30-70 m3/h
ADVANTAGES• Temperature resistance
• Low calorifi c potential
• Prehension ability
• Has a performance guarantee sheet
Applications: Arresting dust, bacteria and aerosols; manometer protection; safety valve exhaust for: nuclear and pharmaceutical indus-tries and hospital establishments.
Type: Filters for glove boxes and containment enclosures.
Media: Glass fi ber paper (fi re classifi cation M1). Gamma irradiation resistance according to standard ASME-AG-1.
Separators: Glass fi ber thread.
Sealant: Polyvinyl chloride (PVC fi re classifi cation M2), or polyurethane (M3 fi re classifi cation) depending on model.
Case: Zinc-bichromate plated sheet metal or stainless steel Z2CN18-10 depending on model.
Gasket: Viton O-ring.
Handle: 1.
Uranine effi ciency: >99.98% (standard NFX 44-011).
Recommended fi nal pressure drop: 600 Pa.
Admissible maximum pressure drop: 1000 Pa.
Uranine decontamination factor: > 5000 (standard NFX 44-011).
Maximum airfl ow: Nominal airfl ow.
Temperature: 120° C maximum in continuous service and 200°C for 1 hour.
Control: Leak detection 100% of products.
Mounting systems: Stainless steel casing.
Reference Model Dimensions (ØxH) mm
Uranine effi ciency Uranine FR
Media area m²
Airfl ow / P m³/h / Pa
Thread gasket Casing Sealant Gasket
Calorifi c potential
MJ
Unit mass
kg
Unit volume
m³
3211.72.00 30 m3/h fi lter with open casing 130x159 At 30 m³/h
> 99.98%At 30 m³/h FR > 5000 0.49
30 / 180 20 / 110 10 / 50
M 622.5 thread
S/Steel sheet Z2CN18-10 PVC Viton R35 5.1 0.65 0.002
3211.90.01 70 m3/h screw fi lter 182x210 At 70 m³/h >99.98%
At 70 m³/h FR > 5000 1.75
70 / 165 50 / 105 30 / 55
M 622.5 thread
Zinc-bi. plated steel
sheet
Polyur-ethane Viton R35 1.47 0.008
3211.90.02 70 m3/h screw fi lter 182x210 At 70 m³/h >99.98%
At 70 m³/h FR > 5000 1.75
70 / 165 50 / 105 30 / 55
M 622.5 thread
S/Steel sheet Z2CN18-10
Polyur-ethane Viton R35 1.47 0.008
30 m3/h
70 m3/h
Casings and filters for containment systems
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com 47
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
Intr
oduc
tion
Med
ium
Effi
cien
cyH
igh
Effi c
ienc
yVe
ry H
igh
Effi c
ienc
yAd
sorp
tion
Casi
ngs
and
fi lte
rsfo
r co
ntai
nmen
t sys
tem
sCo
ntai
nmen
t equ
ipm
ent
Equi
pmen
t for
tem
pora
ry v
entil
atio
nAc
cess
orie
s
METAL CASE VHE FILTERS 300 m3/h
ADVANTAGES• Temperature resistance
• Low calorifi c potential
• Prehension ability
• Has a performance guarantee sheet
Applications: Arresting dust, bacteria and aerosols; manometer protection; safety valve exhaust for: nuclear and pharmaceutical indus-tries and hospital establishments.
Type: Filters for glove boxes and containment enclosures.
Media: Glass fi ber paper (fi re classifi cation M1). Gamma irradiation resistance according to standard ASME-AG1.
Separators: Glass fi ber thread.
Sealant: Polyvinyl chloride (PVC fi re classifi cation M2), or polyurethane (M3 fi re classifi cation) depending on model.
Case: Zinc-bichromate plated sheet metal or stainless steel Z2CN18-10 depending on model.
Gasket: Viton O-ring
Handle: 1.
Uranine effi ciency: >99.98% (standard NFX 44-011).
Recommended fi nal pressure drop: 600 Pa.
Admissible maximum pressure drop: 1000 Pa.
Uranine decontamination factor: > 5000 (standard NFX 44-011).
Maximum airfl ow: Nominal airfl ow.
Temperature: 120° C maximum in continuous service and 200°C for 1 hour.
Control: Leak detection 100% of products.
Mounting systems: Stainless steel casing.
Reference Model Dimensions (ØxH) mm
Uranine effi ciency Uranine FR
Media area m²
Airfl ow / P m³/h / Pa
Thread gasket Casing Sealant Gasket
Calorifi c potential
MJ
Unit mass
kg
Unit volume
m³
3211.91.00 300 m3/h screw fi lter 261x328.8 At 300 m³/h>99.98%
At 300 m³/hFR > 5000 4
300 / 290200 / 180150 / 135
M 1203 thread
Zinc-bi. plated steel
sheet
Polyur-ethane
1 Viton R54
O-ring3.7 0.023
3211.91.01 300 m3/h interlock fi lter 261x394.8 At 300 m³/h>99.98%
At 300 m³/hFR > 5000 4.75
300 / 275200 / 170150 / 120
Zinc-bi. plated steel
sheet
Polyur-ethane
2 Viton O-rings Ø 118.5
3.9 0.027
300 m3/h
Casings and filters for containment systems
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com48
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
IntroductionM
edium Effi ciency
High Effi ciency
Very High Effi ciency
AdsorptionCasings and fi lters
for containment system
sContainm
ent equipment
Equipment for
temporary ventilation
Accessoires
VHE FILTERS 50 m³/hREMOTE HANDLING AND RECHARGEABLE
ADVANTAGES• Waste reduction
• For rechargeable casing
• Remote handling
Applications: Arresting dust, bacteria and aerosols for: nuclear and pharmaceutical industries and hospital establishments.
Type: Case fi lter for glove box and sealed enclosure ventilation.
Filter: Interchangeable cartridge.
Media: Glass fi ber paper (fi re classifi cation M1). Gamma irradiation resistance according to standard ASME-AG1.
Separators: Glass fi ber thread.
Sealant: Polyurethane (M3 fi re classifi cation).
Case: Rigid removable polyvinyl chloride (PVC).
Gasket: Viton (casing) and EPDM (fi lter).
Uranine effi ciency: >99.98% (standard NFX 44-011).
Recommended fi nal pressure drop: 600 Pa.
Admissible maximum pressure drop: 1000 Pa.
Uranine decontamination factor: > 5000 (standard NFX 44-011).
Maximum airfl ow: Nominal airfl ow.
Temperature: 70° C maximum in continuous service.
Control: Leak detection 100% of products.
Reference Model Dimensions(ØxH) mm Uranine effi ciency Uranine FR Media area
m²Airfl ow / P
m³/h / PaUnit mass
kgUnit volume
m³
3255.99.02
+3202.98.03
Rechargeable casing(body + cover)
+Filter cartridge
160x154.7
135x147
At 50 m³/h>99.98%
At 50 m³/hFR > 5000 0.7
50 / 30030 / 14520 / 85
0.94
0.24
0.005
0.002
Casings and filters for containment systems
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com 49
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
Intr
oduc
tion
Med
ium
Effi
cien
cyH
igh
Effi c
ienc
yVe
ry H
igh
Effi c
ienc
yAd
sorp
tion
Casi
ngs
and
fi lte
rsfo
r co
ntai
nmen
t sys
tem
sCo
ntai
nmen
t equ
ipm
ent
Equi
pmen
t for
tem
pora
ry v
entil
atio
nAc
cess
orie
s
ACTIVATED CARBON FILTERS
Applications: Radioiodines trapping or other toxic gases.
Type: Filters for glove boxes and sealed enclosures.
Media: Activated carbon with specifi c impregnation depending on type of gas to be trapped.
Carbon bed: Layer thickness 36 or 50 mm depending on model, kept settled by compression mattress eliminating any risk of leak.
Case: Stainless steel sheet metal Z2CN18-10.
Gasket: Viton.
Handle: 1.
Temperature: 80°C maximum in continuous service.
Control: Filter weighing at 100%
Assembly: Filters to be screwed into stainless steel casings.
Reference Model Dimensions (ØxH) mm
Carbon volume litres
Gas or vapours to trap
Actived carbon type
Carbon impregnation
Max. Airfl ow /P (±20%)
m³/h / Pa
Thread gasket Gasket
Unit mass
kg
Unit volume
m³
3603.30.00 20 m3/h activated carbon fi lter 130x160 1.1 Radioiodes CA102-02 KI and TEDA 20 / 200 M622.5 thread Viton R35 1.2 0.003
3603.40.03 50 m3/h activated carbon fi lter 180x205 3.3 Radioiodes CA102-02 KI and TEDA 50 / 300 M622.5 thread Viton R35 3.8 0.007
3603.30.02 20 m3/h activated carbon fi lter 130x160 1.1 Acids (HF, HCl, H2S, SO2…) CEX002A3 KOH 20 / 130 M62
2.5 thread Viton R35 1.2 0.003
3603.40.04 50 m3/h activated carbon fi lte 180x205 3.3 Acids (HF, HCl, H2S, SO2…) CEX002A3 KOH 50 / 200 M62
2.5 thread Viton R35 3.8 0.007
3603.30.04 20 m3/h activated carbon fi lter 130x160 1.1 Organic compounds LGS048 none 20 / 100 M62
2.5 thread Viton R35 1.2 0.003
3603.40.06 50 m3/h activated carbon fi lte 180x205 3.3 Organic compounds LGS048 none 50 / 150 M62
2.5 thread Viton R35 3.8 0.007
Casings and filters for containment systems
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com50
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
IntroductionM
edium Effi ciency
High Effi ciency
Very High Effi ciency
AdsorptionCasings and fi lters
for containment system
sContainm
ent equipment
Equipment for
temporary ventilation
Accessoires
SCHEMATIC DIAGRAM OF A STAINLESS STEEL CASINGFOR VHE OR ACTIVATED CARBON FILTERS
1 Stainless steel casing (X5 Cr N: 18-10) Flanged or welded entry and exit
2 Stainless steel bulkhead union (X2 Cr N: 18-10) To be screwed with Viton gasket or to be welded
3 Stainless steel connecting fl ange (X2 Cr N: 18-10)
4 Gasket (DN16 and DN 50 Viton, DN100 EPDM)
5 Collar (DN16 Aluminium, DN50 and DN100 Stainless steel)
6 Inside BAG fi lter
7 Filter in casing
8 Containment bag
9 Clogging measurement kit
10 Regulating and/or sectional valve
Casings and filters for containment systems
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com 51
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
Intr
oduc
tion
Med
ium
Effi
cien
cyH
igh
Effi c
ienc
yVe
ry H
igh
Effi c
ienc
yAd
sorp
tion
Casi
ngs
and
fi lte
rsfo
r co
ntai
nmen
t sys
tem
sCo
ntai
nmen
t equ
ipm
ent
Equi
pmen
t for
tem
pora
ry v
entil
atio
nAc
cess
orie
s
Reference ModelCase
Airfl ow /P m³/h / Pa(1)
Operating pressure
Intervention bag
reference.
Reference for mounting
fi lter
Cover gasket
AccessoriesUnit
mass kg
Unit volume
m³Aluminium
collarViton
O-ring
S/Steel connection to weld with
conical fl angeValve
6202.97.01S/Steel casing
5 m3/h with conical fl anges DN 16 KF
5 / 20 0 to 2000 Pa 6202.07.14 3205.11.00(2) Silicon 6202.12.42 6202.12.41 6202.02.63 6202.97.65 0.8 0.003
6202.97.30S/Steel casing
5 m3/h to be welded DN 15 ISO
5 / 20 0 to 2000 Pa 6202.07.14 3205.11.00(2) Silicon 0.8 0.003
6202.97.32
Vacuum resistant S/Steel casing
5 m3/h with conical fl anges DN 16 KF
5 / 20 ± 1 bar 6202.07.14 3205.11.00(2) Viton 6202.12.42 6202.12.41 6202.02.63 2.8 0.003
6202.97.33
Vacuum resistant S/Steel casing
5 m3/h to be welded DN 15 ISO
5 / 20 ± 1 bar 6202.07.14 3205.11.00(2) Viton 2.8 0.003
(1) Between fl anges, without fi lter and without valve.
(2) Foresee a cover 6202.92.81.
To be welded on casing To be attached to casing with fl anges
STAINLESS STEEL CASINGS 5 m3/h FOR 3205.11.00 FILTERS
Casings and filters for containment systems
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com52
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
IntroductionM
edium Effi ciency
High Effi ciency
Very High Effi ciency
AdsorptionCasings and fi lters
for containment system
sContainm
ent equipment
Equipment for
temporary ventilation
Accessoires
STAINLESS STEEL CASINGS 30 m³/h
Reference ModelCase
Airfl ow /P m³/h / Pa
Operating pressure
Intervention bag
reference
Reference for mounting
fi lter
Cover gasket
AccessoriesUnit
mass kg
Unit volume
m³
S/Steel bulkhead crossing
S/Steel collar
Viton O-ring
S/Steel connection to weld with
conical fl angeValve
6202.91.01S/Steel casing
30 m3/h with conical fl anges DN 50
30 / 2020 / 1510 / 10
0 to 2000 Pa 6202.02.17
3201.01.01 3202.04.01 3211.72.00 3603.30.00
Silicon 6202.92.11 (To screw) 6202.12.28 6202.12.27 6202.01.10 6202.09.39 3 0.01
6202.91.11S/Steel casing 30 m3/h to be
welded DN 50 ISO
30 / 2020 / 1510 / 10
0 to 2000 Pa 6202.02.17
3201.01.01 3202.04.01 3211.72.00 3603.30.00
Silicon 6202.02.14 (To weld) 6202.09.33 3 0.01
6202.91.31
Vacuum resistant S/Steel casing
30 m3/h with conical fl anges DN 50
30 / 2020 / 1510 / 10
± 1 bar 6202.02.17
3201.01.01 3202.04.01 3211.72.00 3603.30.00
Viton 6202.92.11 (To screw) 6202.12.28 6202.12.27 6202.01.10 5.3 0.012
6202.91.32
Vacuum resistant S/Steel casing 30 m3/h to be
welded
30 / 2020 / 1510 / 10
± 1 bar 6202.02.17
201.01.01 3202.04.01 3211.72.00 3603.30.00
Viton6202.02.14
(To be welded)
5.3 0.012
6202.96.46 Clogging measurement kit
To be welded on casing
To be attached to casing with fl anges
Casings and filters for containment systems
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com 53
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
Intr
oduc
tion
Med
ium
Effi
cien
cyH
igh
Effi c
ienc
yVe
ry H
igh
Effi c
ienc
yAd
sorp
tion
Casi
ngs
and
fi lte
rsfo
r co
ntai
nmen
t sys
tem
sCo
ntai
nmen
t equ
ipm
ent
Equi
pmen
t for
tem
pora
ry v
entil
atio
nAc
cess
orie
s
STAINLESS STEEL CASINGS 70 m³/h
Reference ModelCase
Airfl ow /P m³/h / Pa
Operating pressure
Intervention bag
reference
Reference for mounting
fi lter
Cover gasket
AccessoriesUnit
mass kg
Unit volume
m³
S/Steel bulkhead crossing
S/Steel collar
Viton O-ring
S/Steel connection to weld with
conical fl angeValve
6202.95.01S/Steel casing
70 m3/h with conical fl anges DN 50
70 / 35 50 / 20 30 / 10
0 to 2000 Pa 620202.18
3211.90.01 3211.90.02 3603.40.03 3202.04.01
Silicon 6202.92.11 (To screw) 6202.12.28 6202.12.27 6202.01.10 6202.09.39 3.6 0.02
6202.95.11S/Steel casing 70 m3/h to be
welded DN 50 ISO
70 / 35 50 / 20 30 / 10
0 to 2000 Pa 620202.18
3211.90.01 3211.90.02 3603.40.03 3202.04.01
Silicon 6202.02.14 (To weld) 6002.09.33 3.6 0.02
6202.95.31
Vacuum resistant S/Steel casing
70 m3/h with conical fl anges DN 50
70 / 35 50 / 20 30 / 10
± 1 bar 620202.18
3211.90.01 3211.90.02 3603.40.03 3202.04.01
Viton 6202.92.11 (To screw) 6202.12.28 6202.12.27 6202.01.10 7.5 0.025
6202.95.32
Vacuum resistant S/Steel casing 70 m3/h to be
welded DN 50 ISO
70 / 35 50 / 20 30 / 10
± 1 bar 620202.18
3211.90.01 3211.90.02 3603.40.03 3202.04.01
Viton 6202.02.14 (To weld) 7.5 0.025
6202.96.47 Clogging measurement kit
To be welded on casing
To be attached to casing with fl anges
Casings and filters for containment systems
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com54
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
IntroductionM
edium Effi ciency
High Effi ciency
Very High Effi ciency
AdsorptionCasings and fi lters
for containment system
sContainm
ent equipment
Equipment for
temporary ventilation
Accessoires
STAINLESS STEEL CASINGS 300 m³/h
Reference ModelCase
Airfl ow /P m³/h / Pa
Operating pressure
Intervention bag
reference
Reference for mounting
fi lter
Cover gasket
AccessoriesUnit
mass kg
Unit volume
m³
S/Steel bulkhead crossing
S/Steel collar
EPDM O-ring
S/Steel connection to weld with
conical fl ange
Valve
6202.96.03S/Steel casing 300 m3/h with
conical fl anges DN 100
300 / 100 200 / 50 150 / 25
0 to 2000 Pa 6202.06.44 3211.91.01 Silicon 6202.13.67 6202.13.47 6202.01.47 6202.09.35 10 0.06
6202.96.30S/Steel casing
300 m3/h to be welded DN 100 ISO
300 / 100 200 / 50 150 / 25
0 to 2000 Pa 6202.06.44 3211.91.01 Silicon 6202.09.41 10 0.06
Casings and filters for containment systems
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com 55
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
Intr
oduc
tion
Med
ium
Effi
cien
cyH
igh
Effi c
ienc
yVe
ry H
igh
Effi c
ienc
yAd
sorp
tion
Casi
ngs
and
fi lte
rsfo
r co
ntai
nmen
t sys
tem
sCo
ntai
nmen
t equ
ipm
ent
Equi
pmen
t for
tem
pora
ry v
entil
atio
nAc
cess
orie
s
PUSH-PUSH FILTERS AND SYSTEMS
ADVANTAGES• Adapted to small airfl ows
• Irradiation resistant
FILTER:
Applications: Arresting dust, bacteria and aerosols for industries: nuclear, pharmaceuti-cal, etc...
Type: VHE fi lter.
Media: Glass fi ber (fi re classifi cation M1). Gamma irradiation resistance according to standard ASME-AG1.
Separators: Glass fi ber thread.
Sealant: Polyvinyl chloride (PVC fi re classifi cation M2).
Case: Stainless steel perforated sheet metal Z2CN18-10.
Gasket: Double lip, in one single piece, made of EPT (Ethylene-Propylene Terpolymer).
Uranine effi ciency: > 99.98% (standard NFX 44-011) .
Recommended fi nal pressure drop: 400 Pa.
Uranine decontamination factor: > 5000 (standard NFX 44-011).
Maximum airfl ow: Nominal airfl ow.
Temperature: 110°C maximum in continuous service.
Control: Leak detection 100% of products.
Assembly system: Push-push system.
Reference Model Dimensions (ØxH) mm Uranine FR Media area
m²Airfl ow / Nominal P
m³/h / PaCalorifi c potential
MJUnit mass
kgUnit volume
m³
3206.03.00 35 m³/h fi lter 152x162 > 5000 0.7 35 / 130 3.1 0.365 0.003
Reference Model Dimensions (ØxH) mm Airfl ow m³/h Unit mass kg Unit volume m³
6211.01.00 Stainless steel system with pin 159x540 35 20 0.01
6211.51.00 PVC system with pin 160x540 35 10 0.01
6211.31.00 Stainless steel system with receptacle 159x625 35 20 0.01
6211.81.00 PVC system with receptacle 160x625 10 20 0.01
For versions assembled outside the enclosure and armoured versions, please consult us.
SYSTEM:
Applications: Equipping glove boxes for nuclear and pharmaceutical industries.
Type: Travelling device.
Description: Stainless steel tube X2CrNi 18-09 or polyvinyl chloride. Adjustable fl ange for assembly on glove boxes. Lateral spurs for the admission or extraction of air or gas. Pressure taps for controlling the fi lter’s pressure drop. Safety pin or receptacle with lateral spurs.
For fi lters: Power reference 3206.03.00.
Maximum airfl ow: 35 m³/h.
Temperature: 110°C maximum in continuous service for stainless steel model and 70°C for PVC model.
Operating principle: 3206.03.00 fi lters slide inside the tube, tightness made by double lip gasket. The new fi lter replaces the old one by pushing it inside the glove box without breaking the tightness.
Assembly: The push-push system can be installed in a vertical or horizontal position. The number of fi lters to be installed in the push-push system on admission and on extraction of the enclosures is equal to 1 for category III and 2 for categories I and II according to standard NFM 62.202.
Casings and filters for containment systems
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com56
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
IntroductionM
edium Effi ciency
High Effi ciency
Very High Effi ciency
AdsorptionCasings and fi lters
for containment system
sContainm
ent equipment
Equipment for
temporary ventilation
Accessoires
PUSH-PUSH FILTERS AND SYSTEMSSCHEMATIC DIAGRAM
DESIGNATION MATERIAL REFERENCES
SET
(with
out
32
06
-03
fi lte
r)
With pin 5STAINLESS STELL 6211-01
PVC 6211-51
With receptacle and lateral spur 4
STAINLESS STELL 6211-31
PVC 6211-81
SPA
RE
PAR
TS
Obturator 2STAINLESS STELL 6210-05
PVC 6210-55
Ejection tappet 3 PVC 6210-56
Receptacle with lateral spur 4
STAINLESS STELL 6210-02
PVC 6210-52
Pin 5STAINLESS STELL 6210-03
PVC 6210-53
FILTERS REPLACEMENT
- 1 Put out the obturator 2
- 2 Take out the tappet 5 or, depending on the case, open the receptacle 4
- 3 Insert a new fi lter by the opposite side of the joint
- 4 Slid the fi lter in order to evacuate the sealed fi lter with the ejection tappet 3
- 5 Put back the obturator, the fl ange and the receptacle
1 Tube
2 Obturator
3 Ejection tappet
4 Receptacle
5 Pin
Casings and filters for containment systems
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com 57
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
Intr
oduc
tion
Med
ium
Effi
cien
cyH
igh
Effi c
ienc
yVe
ry H
igh
Effi c
ienc
yAd
sorp
tion
Casi
ngs
and
fi lte
rsfo
r co
ntai
nmen
t sys
tem
sCo
ntai
nmen
t equ
ipm
ent
Equi
pmen
t for
tem
pora
ry v
entil
atio
nAc
cess
orie
s
FILTERS FOR TIGHTNESS ENCLOSURES
ADVANTAGES• Evacuation by standardised sealed
devices
• Remote handling
• Compact version for waste reduction
Applications: Arresting dust and aerosols for nuclear industries.
Type: Remote handling VHE fi lters for sealed enclosures.
Media: Glass fi ber paper (fi re classifi cation M1) .
Separators: Glass fi ber thread.
Sealant: Polyvinyl chloride (PVC - fi re classifi cation M2).
Case: Galvanized or stainless steel sheet metal Z2CN18-10 with strip for remote handling
Gasket: Double lip, in one single piece, made of EPT (Ethylene-Propylene Terpolymer).
Uranine effi ciency: > 99.98% (standard NFX 44-011) .
Uranine decontamination factor: > 5000 (standard NFX 44-011) .
Maximum airfl ow: Nominal airfl ow.
Temperature: 120°C maximum in continuous service and (200°C at peak operating for 1 hour maximum).
Control: Leak detection 100% of products.
Assembly system: Casings for radioactive cells.
Reference Model Dimensions (ØxH) mm Uranine FR Media area
m²Airfl ow / Nominal P
m³/h / Pa Frame Calorifi c potential MJ
Unit mass kg
Unit volume m³
3271.01.00 Galvanised fi lter 245x380 > 5000 3.39 300 / 240 Galvanized steel 7.4 2.0 0.02
3271.11.00 Stainless steel fi lter 245x380 > 5000 3.39 300 / 240 Stainless steel 7.4 2.0 0.02
3271.21.00 Compact stainless steel fi lter 245x240 > 5000 3.00 300 / 270 Stainless steel 2.5 0.03
SPARK ARRESTER
Reference Model Dimensions (AxB) mm Uranine FR Media area
m²Airfl ow / Nominal P
m³/h / Pa Frame Calorifi c potential MJ
Unit mass kg
Unit volume m³
6271.91.00 Spark arrester 272x320 G3 0.08 300 / 65 Stainless steel 1.15 0.004
6271.92.00 Spark arrester 320x545 G3 0.17 600 / 65 Stainless steel 2.30 0.009
6271.93.00 Spark arrester 272x595 G3 0.16 600 / 65 Stainless steel 2.15 0.008
SPARK ARRESTERSee SPARK ARRESTER table
Casings and filters for containment systems
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com58
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
IntroductionM
edium Effi ciency
High Effi ciency
Very High Effi ciency
AdsorptionCasings and fi lters
for containment system
sContainm
ent equipment
Equipment for
temporary ventilation
Accessoires
CASINGS FOR RADIO-ACTIVE CELLS
ADVANTAGES• Tightness guaranteed
Applications: Equipping cells for handling radioactive products.
Type: Casing for remote handling VHE fi lters.
Description:
• Casing made of 3 mm stainless steel sheet metal welded tight.
• Manufactured gasket seat made of 10 mm stainless steel.
• Protection by stripping and passivating.
For fi lters: VHE remote handling.
Maximum airfl ow: Filter nominal airfl ow.
Temperature: 120°C maximum in continuous service and (200°C at peak operating for 1 hour maximum).
Controls:
• Dimensional, appearance, operating.
• Visual control of welds.
• Gasket seat weld leak detection.
• Gasket seat tightness under depression of 250 Pa
• Surface protection.
Assembly: These casings have to be installed so that their gasket seats are perfectly horizontal.
Accessories:
• Cover made of perforated sheet metal or with lateral air inlet.
• Spark arrester fi lter (see below).
Reference Model Dimensions (AxB) mm
Nmber of fi lters
Spark arrester numberFlange Unit mass
kgUnit volume
m³6271.91.00 6271.92.00 6271.93.00
6271.12.00 In-line layout 558x337 2 1 DN 100 PN 16 45 0.15
6271.13.00 In-line layout 833x337 3 1 1 DN 125 PN 16 62 0.22
6271.14.00 In-line layout 1108x337 4 2 DN 150 PN 16 78 0.29
6271.22.00 2 rows layout 558x612 4 2 DN 150 PN 16 65 0.27
Casings and filters for containment systems
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com 59
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
Intr
oduc
tion
Med
ium
Effi
cien
cyH
igh
Effi c
ienc
yVe
ry H
igh
Effi c
ienc
yAd
sorp
tion
Casi
ngs
and
fi lte
rsfo
r co
ntai
nmen
t sys
tem
sCo
ntai
nmen
t equ
ipm
ent
Equi
pmen
t for
tem
pora
ry v
entil
atio
nAc
cess
orie
s
BSS DUCT CASINGS
ADVANTAGES• Space saving
• Possible to replace without breaking tightness (assembly with canvas sleeves)
• For mobile and temporary use
Application: Temporary or mobile ventilation in nuclear and pharmaceutical industries and hospital establishments.
Type: Tubular duct casing without fl anges.
Description: Casing made of soft stainless steel sheet metal 15/10 mm thickness with assembly by continuous weld and protection by glycerophtalic paint or made of polyvinyl chloride (PVC). The tightness between the fi lters and the casing as well as that of the cover is made by special adhesive (vinyl) tape.
For fi lters: VHE and activated carbon ones.
Recommended airfl ow: 100 m³/h per fi lter.
Temperature: 60°C maximum in continuous service for PVC models and 70°C for mild steel models.
Assembly: The air inlet has to be made on the cover side. These casing have been designed to only work in depression. Connecting to the ventilation circuit is made by canvas sleeves that are held still by adhesive tape.
Accessories: Adhesive tape ref. 1900.10.00: for resistance at 70°C maximum in continuous service. Length: 33 m.
Reference Model Number of fi lters
For fi lters WxHxD mm
Airfl ow / Nominal P* m³/h / Pa H I E Ø B Connection
sleeveBSS
equipedUnit
mass kgVolume
m³
6335.01.02 Mild steel 1 600x65x202 100 / 55 200 / 205 615 76 450 62 100 6900.02.00 6335.44.55 6 0.02
6335.02.02 Mild steel 21
600x65x202 600x130x202
200 / 40 400 / 195 615 142 490 120 100 6900.03.00 6335.47.55 9 0.04
6335.04.02 Mild steel 42
600x65x202 600x130x202
400 / 25 800 / 115 615 274 490 260 93 6900.04.00 6335.45.55 12.5 0.08
6335.51.00 PVC 1 600x65x202 100 / 55 200 / 205 624 88 454 63 100 6900.02.00 4 0.02
6335.52.00 PVC 21
600x65x202 600x130x202
200 / 40 400 / 195 624 154 494 125 100 6900.03.00 6.5 0.05
6335.54.00 PVC 42
600x65x202 600x130x202
400 / 25 800 / 115 624 286 544 250 90 6900.04.00 9 1.00
* between tubing without fi lters.
Notes
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com60
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
IntroductionM
edium Effi ciency
High Effi ciency
Very High Effi ciency
AdsorptionCasings and fi lters
for containment system
sContainm
ent equipment
Equipment for
temporary ventilation
Accessoires
Containment equipment
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com 61
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
Intr
oduc
tion
Med
ium
Effi
cien
cyH
igh
Effi c
ienc
yVe
ry H
igh
Effi c
ienc
yAd
sorp
tion
Casi
ngs
and
fi lte
rsfo
r co
ntai
nmen
t sys
tem
sCo
ntai
nmen
t equ
ipm
ent
Equi
pmen
t for
tem
pora
ry v
entil
atio
nAc
cess
orie
s
GAS ADSORBERS
page 82
CAGES
page 81
ISOLATING DAMPERS
page 73
TIGHT LOCK CASINGSMULTICELLULAR TYPE
page 68
CONTENTS
GENERAL POINTS
page 62
TIGHT LOCK CASINGSUNIT TYPE
page 63
BUTTERFLY VALVES
page 67
TIGHT LOCK CASINGSMULTICELLULAR TYPECONNECTION FLANGES
page 72
SURFACE TREATMENT SPECIFIC FOR CASING WITH TIGHT LOCK AND ISOLATING DAMPER
page 74
BAG OUT PORT TYPE PLATFORMS
page 78
CRADLE PLATFORMS
page 79
CAM PLATFORMS
page 80
PROCEDURES
page 75
DIFFERENT CONTAINMENT EQUIPMENT DESIGNS
There are currently many designs for making fi ltration equipment for air extrac-ted from contaminable areas
TIGHT LOCK CASINGS
Principle:
These casings have the advantage of being able to replace contaminated fi lters under a plastic bag i.e. without any tightness interruption. By this way, the process provides total protection for the personnel against risks of accidental contamination.
Description:
Each casing has as many cells as fi lters. These are limited in the upper part by a gasket seat and in the lower part by a vertically mobile sliding resting on two camshafts. The tightness between the casing and the fi lter is made by a gasket attached to the fi lter and compressed under the effect of the two camshafts.
The position of the guide rail supporting the fi lter can be height adjusted using a mechanical device. The adjustment is made in the factory.
Usually, air circulates from the top to the bottom in the fi ltering cell, avoiding contaminating the work area when replacing the fi lter. Moreover, when remo-ving the fi ltering cell, there is no risk of dust dropping into the casing. Individual casings can also be installed on edge, the air then circulates horizontally in the cells, but if possible preference is given to the fi rst position.
Changing the fi lters:
Described on page 75-77 “Procedures”.
Taking pressure reading in-situ (as an option):
Networks of high airfl ow installation tubes do not always allow for compliance with the installation rules for injection and sampling points for in-situ control of VHE fi lters.
On request, multi-cell tight lock casings can be fi tted with Ø200 points allowing these tests to be made, at a reduced air-fl ow, casing by casing, using two specifi c CAMFIL mobile units.
The units are connected to the casing by tubes isolated from the network by two dampers, made up of a uranine generator, sampling devices, a fl ow-meter, a ventila-tor and a VHE safety fi lter.
PLATFORMS
Principle:
There are three types of platforms:• with canvas sleeves: this type of plat-
form has the advantage of allowing, in case of emergency contamination - a case for nuclear reactors – the fi lter to be replaced in a plastic protection bag. However, it is necessary to remove the vinyl safe change bags when turning the ventilation on;
• with cradles;• with cams.
These last two platform types require using a protective suit when replacing the fi lters.
GAS ADSORBERS(SOFILTRAD model)
These are adsorbers with fi xed beds and loading and unloading beds using pneumatic means for radioiodines trap-ping and toxic gases. They are more and more used for high airfl ows, from some thousand m3/h.
SOFILTRAD gas adsorbers can either be incorporated into platform type equipment, or used together with tight lock casings. In the latter case, the adsorber has to be fi tted with two plenums (1 upstream and 1 downstream).
The advantages of these radioiodine adsor-bers are as follows:• Space saving: volume needed lower
than that for carbon cells installed on platforms or tight lock casings.
• Easy and safe operating: no direct work in the contaminated area.
• Cost saving due to only replacing activated carbon.
• Reduction in quantity of waste.• The adsorbers are designed according to
the following parameters:- Airfl ow to be processed;- Admitted speed.
• Thickness of adsorbent beds (function, associated with the required speed and effi ciency).
• Space available.• Geometry of the fi ltration equipment
planned upstream and downstream.
Containment equipment
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com62
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
IntroductionM
edium Effi ciency
High Effi ciency
Very High Effi ciency
AdsorptionCasings and fi lters
for containment system
sContainm
ent equipment
Equipment for
temporary ventilation
Accessoires
GENERAL POINTS
DIFFERENT CONTAINMENT EQUIPMENT DESIGNS
There are currently many designs for ma-king fi ltration equipment for air extracted from contaminable areas
TIGHT LOCK CASINGS
Principle:
These casings have the advantage of being able to replace contaminated fi lters under a plastic bag i.e. without any tightness interruption. By this way, the process pro-vides total protection for the personnel against risks of accidental contamination.
Description:
Each casing has as many cells as fi lters. These are limited in the upper part by a gasket seat and in the lower part by a ver-tically mobile sliding resting on two cams-hafts. The tightness between the casing and the fi lter is made by a gasket attached to the fi lter and compressed under the effect of the two camshafts.
The position of the guide rail supporting the fi lter can be height adjusted using a mechanical device. The adjustment is made in the factory.
Usually, air circulates from the top to the bottom in the fi ltering cell, avoiding conta-minating the work area when replacing the fi lter. Moreover, when removing the fi lte-ring cell, there is no risk of dust dropping into the casing. Individual casings can also be installed on edge, the air then circulates horizontally in the cells, but if possible preference is given to the fi rst position.
Tightness control:
Each casing is subject to 3 controls:• Size, appearance, operating test, mainly
covering the fi lter lifting system.• General tightness test for the casing
made under pressure of 3000Pa.• Filters’ gasket seat tightness test made
under pressure of 1500Pa.
Isolating dampers:
For insulting tight lock casings from the rest of the installation to allow the fi lters to be changed without stopping the ven-tilation if the casings are bypassed, these dampers are positioned upstream and downstream of the casings.
Changing the fi lters:
Described on page 75-77 “Procedures”.
Taking pressure reading in-situ (as an option):
Networks of high airfl ow installation tubes do not always allow for compliance with the installation rules for injection and sampling points for in-situ control of VHE fi lters.
On request, multi-cell tight lock casings can be fi tted with Ø200 points allowing these tests to be made, at a reduced air-fl ow, casing by casing, using two specifi c CAMFIL mobile units.
The units are connected to the casing by tubes isolated from the network by two dampers, made up of a uranine generator, sampling devices, a fl ow-meter, a ventila-tor and a VHE safety fi lter.
PLATFORMS
Principle:
There are three types of platforms:• with canvas sleeves: this type of plat-
form has the advantage of allowing, in case of emergency contamination - a case for nuclear reactors – the fi lter to be replaced in a plastic protection bag. However, it is necessary to remove the vinyl safe change bags when turning the ventilation on;
• with cradles;• with cams.
These last two platform types require using a protective suit when replacing the fi lters.
Description:
The characteristics of each model are des-cribed in detail on pages 78-80.
The platforms can be made up of up to 4 fi ltration levels as shown on the dia-grams.
It is also possible to incorporate a SOFILTRAD gas adsorber into the plat-form.
GAS ADSORBERS(SOFILTRAD model)
These are adsorbers with fi xed beds and loading and unloading beds using pneu-matic means for radioiodines trapping and toxic gases. They are more and more used for high airfl ows, from some thousand m3/h.
SOFILTRAD gas adsorbers can either be incorporated into platform type equip-ment, or used together with tight lock ca-sings. In the latter case, the adsorber has to be fi tted with two plenums (1 upstream and 1 downstream).
The advantages of these radioiodine ad-sorbers are as follows:• Space saving: volume needed lower
than that for carbon cells installed on platforms or tight lock casings.
• Easy and safe operating: no direct work in the contaminated area.
• Cost saving due to only replacing acti-vated carbon.
• Reduction in quantity of waste.• The adsorbers are designed according to
the following parameters:- Airfl ow to be processed;- Admitted speed.
• Thickness of adsorbent beds (function, associated with the required speed and effi ciency).
• Space available.• Geometry of the fi ltration equipment
planned upstream and downstream.
SOFILTRAD gas adsorbers can be fi lled with various types of adsorbents. Gene-rally, for air extraction on nuclear reactors, we use activated carbon impregnated with 1% potassium iodide as this type of adsorbent currently has the best effi cien-cy characteristics as opposed to methyl iodide.
Due to their construction and their design (large protective layer in the top part, etc.), SOFILTRAD gas adsorbers have effi ciency levels that match the effi ciencies of carbon cells. They meet the French and American specifi cations in force.
Containment equipment
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com 63
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
Intr
oduc
tion
Med
ium
Effi
cien
cyH
igh
Effi c
ienc
yVe
ry H
igh
Effi c
ienc
yAd
sorp
tion
Casi
ngs
and
fi lte
rsfo
r co
ntai
nmen
t sys
tem
sCo
ntai
nmen
t equ
ipm
ent
Equi
pmen
t for
tem
pora
ry v
entil
atio
nAc
cess
orie
s
TIGHT LOCK CASINGS UNIT TYPE PAGE 1/4
ADVANTAGES• Tightness guaranteed
• Temperature resistance
• Secure fi lter clamping device
• Decontamination
Applications: Extraction of contaminated air in nuclear buildings and laboratories with biological risks.
Type: Tight lock casings allowing the removal or the installation of fi lters without breaking the tightness.
Description:• Mild steel or 3mm stainless steel sheet metal casing, sealed by weld with glove opening obscured by an fi lter access cover.• Protection by decontaminable paint (mild steel) or by stripping and passivating (stainless steel).• Gasket clamping of the fi lter made by one or two camshafts working on Z2CN18-10 stainless steel guide rails with safety device in
“locked” and “unlocked» position.• A dial manometer (0 to 1000 Pa scale) by level to indicate the development of the clogging (supplied assembled with 2 possible
orientations) and a cover manoeuvre key.• A vent to make it easier to form safe change bags.
For fi lters: Medium and High Effi ciency Filters, VHE fi lters and activated carbon fi lters.
Maximum airfl ow: Filter nominal airfl ow.
Temperature: 120°C in continuous service and 200°C in emergency operating for 2 hours.
Controls: Size, Appearance, Operating. Visual control of welds. Gasket seat weld leak detection. Overall tightness under pressure of 3000 Pa according to NFM 62200 class 3 or ISO 10648 class 4. Gasket seat tightness under depression of 1500 Pa, maximum leak airfl ow 10-5 of the casing’s nominal airfl ow. Surface protection.
Assembly: The direction of the air fl ow indicated by an arrow on the side of the casing has to be respected so as to not contaminate the work area. The casing can be installed:• Vertical circulation of air, entry fl ange must be at the top.• Horizontal circulation of air, entry fl ange on the right or left, covers vertical.
Replacing fi lters: Sealed, with intervention bags assembled on gloves openings and using a handling console (only for 610x305x292 and 610x610x292 mm fi lters).Two isolation valves «upstream” and “downstream” will be foreseen to insulate the casing during this operation. If the ventilation cannot be stopped, the “downstream” valve can be removed.
N.B.: For resistance to seismic or to specifi c operating pressures, please consult us.
Containment equipment
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com64
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
IntroductionM
edium Effi ciency
High Effi ciency
Very High Effi ciency
AdsorptionCasings and fi lters
for containment system
sContainm
ent equipment
Equipment for
temporary ventilation
Accessoires
TIGHT LOCK CASINGS UNIT TYPE PAGE 2/4
ADVANTAGES• Tightness guaranteed
• Temperature resistance
• Secure fi lter clamping device
• Decontamination
Mild steel casing Reference
Stainless steel casing Reference Model Max. working pressure
PaAirfl ow / Nominal P*
m³/h / PaFor fi lters
WxHxD mmFlange connection
mmUnit mass
kg
7110.11.00 7210.11.00 Single casing ± 8000 190 / 80450 / 260 600x130x202 DN 100 PN 16 40
Accessories: vinyl bag, handling console, see page 88.
* P: between fl anges, without fi lter and without valve.
Containment equipment
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com 65
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
Intr
oduc
tion
Med
ium
Effi
cien
cyH
igh
Effi c
ienc
yVe
ry H
igh
Effi c
ienc
yAd
sorp
tion
Casi
ngs
and
fi lte
rsfo
r co
ntai
nmen
t sys
tem
sCo
ntai
nmen
t equ
ipm
ent
Equi
pmen
t for
tem
pora
ry v
entil
atio
nAc
cess
orie
s
TIGHT LOCK CASINGS UNIT TYPE PAGE 3/4
ADVANTAGES• Tightness guaranteed
• Temperature resistance
• Secure fi lter clamping device
• Decontamination
Mild steel casing Reference
Stainless steel casing Reference Model Max. working
pressure PaAirfl ow / Nominal P*
m³/h / Pa Confi guration For fi ltersWxHxD mm
Flange connectionmm
Unit masskg
7120.11.00 7220.11.00 Single casing ± 8000 600 / 20 1500 / 120 1 stage fi lter 610x305x292 DN 200 PN 10 80
7120.21.00 7220.21.00 Single casing ± 8000 600 / 20 1500 / 120 2 stage fi lter 610x305x292 DN 200 PN 10 125
7130.11.00 7230.11.00 Single casing ± 8000 600 / 20 1500 / 120
1 stage prefi lter + 1 stage fi lter
610x305x50 610x305x292 DN 200 PN 10 125
Accessories: vinyl bag, handling console, see page 88.
* P: between fl anges, without fi lter and without valve.
For stainless steel version, the cord between the fl anges increases by 40 mn.
Containment equipment
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com66
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
IntroductionM
edium Effi ciency
High Effi ciency
Very High Effi ciency
AdsorptionCasings and fi lters
for containment system
sContainm
ent equipment
Equipment for
temporary ventilation
Accessoires
TIGHT LOCK CASINGS UNIT TYPE PAGE 4/4
ADVANTAGES• Tightness guaranteed
• Temperature resistance
• Secure fi lter clamping device
• Decontamination
Mild steel casing Reference
Stainless steel casing Reference Model Max. working
pressure PaNumber of
fi lters
Airfl ow / Nominal P* m³/h / Pa
molecular fi ltration particle fi ltration
Confi guration For fi ltersWxHxD mm
Flange connection
mm
Unit masskg
CASING FOR FILTER 610x610
7140.11.00 7240.11.00 Single casing ± 8000 11
1200 / 25 3400 / 140 1 stage fi lter 610x610x292 DN 300 PN 10 130
7140.21.00 7240.21.00 Single casing ± 8000 11
1200 / 25 3400 / 140 2 stage fi lter 610x610x292 DN 300 PN 10 190
7150.11.00 7250.11.00 Single casing ± 8000 11
1200 / 253400 / 140
1 stage prefi lter + 1 stage fi lter
610x610x50 610x610x292 DN 300 PN 10 165
CASING FOR FILTER 610x305, the casing is equipped with the intermediate sealing surface
7160.11.00 7260.11.00 Single casing ± 8000 11
1200 / 25 3000 / 140 1 stage fi lter 610x305x292 DN 300 PN 10 130
7160.21.00 7260.21.00 Single casing ± 8000 11
1200 / 25 3000 / 140 2 stage fi lter 610x305x292 DN 300 PN 10 190
7170.11.00 7270.11.00 Single casing ± 8000 11
1200 / 253000 / 140
1 stage prefi lter + 1 stage fi lter
610x305x50 610x305x292 DN 300 PN 10 165
Accessories: vinyl bag, handling console, see page 88.
* P: between fl anges, without fi lter and without valve.
For stainless steel version, the cord between the fl anges increases by 40 mn.
Containment equipment
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com 67
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
Intr
oduc
tion
Med
ium
Effi
cien
cyH
igh
Effi c
ienc
yVe
ry H
igh
Effi c
ienc
yAd
sorp
tion
Casi
ngs
and
fi lte
rsfo
r co
ntai
nmen
t sys
tem
sCo
ntai
nmen
t equ
ipm
ent
Equi
pmen
t for
tem
pora
ry v
entil
atio
nAc
cess
orie
s
BUTTERFLY VALVES
ADVANTAGES• Tightness guaranteed
• Can be adapted to all models including those with an Intermediate gasket seat
Applications: Insulation tight lock casing unit.
Type a: Butterfl y valve tightness on EPDM collar. Manual command by adjustable quarter turn handle. Can be blocked in all positions.
Body and butterfl y:Standard model: body and butterfl y made of cast iron GS 400-15 (NFA 32201).Stainless steel butterfl y model: the body is made of cast iron GS 400-15 (NFA 32201) and the butterfl y is made of stainless steel 316 (NFA 35573).Stainless steel model: body and butterfl y made of stainless steel 316 (NFA 35573).
Axle: Z33C13 (NFA 35573).
Sleeve: EPDM.
Handle: Cast iron GS (NFA 32201).
Screws: Stainless steel 316 (NFA 35573).
Protection: Decontaminable paint for body, butterfl y and handle (except stainless steel model).
Colour: Light grey.
Temperature: Fluid: air from 10°C to 120°C in continuous service 200°C 2 emergency hours.
Tightness: 10-5 of the nominal airfl ow at 3000 Pa.
Assembly: Recommended assembly between fl anges according to plan opposite.
ReferencesDN
Dimensions In mm Airfl ow / Nominal Pm³/h / Pa
Unit masskgStandard S/Steel butterfl y Stainless steel A B C D E
7905.50.10 7905.50.12 7905.50.13 100 210 106 52 152 290 450 / 70 6.5
7905.60.10 7905.60.12 7905.60.13 200 285 164 60 265 450 1500 / 60 17.1
7905.65.10 7905.65.12 7905.65.13 250 311 200 68 318 450 1500 / 50 28.4
7905.70.10 7905.70.12 7905.70.13 300 336 238 78 371 450 3400 / 45 32.2
Material available on order.
Containment equipment
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com68
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
IntroductionM
edium Effi ciency
High Effi ciency
Very High Effi ciency
AdsorptionCasings and fi lters
for containment system
sContainm
ent equipment
Equipment for
temporary ventilation
Accessoires
MULTICELLULAR TYPE TIGHT LOCK CASINGS PAGE 1/4
ADVANTAGES• Single-block casing
• Sealant guaranteed
• Temperature resistance
• Secure fi lter clamping device
• Decontamination
Applications: Extraction of contaminated air in nuclear buildings and laboratories with biological risks.
Type: Tight lock casings allowing the removal or the installation of fi lters without breaking the tightness.
Description:• Mild steel or 3 and 4mm stainless steel sheet metal casing, sealed by weld with glove openings obscured by a fi lter access cover.• Protection by decontaminable paint (mild steel) or by stripping and passivating (stainless steel).• Gasket clamping of the fi lter made by one or two camshafts working on X2CrNi18-9 stainless steel guide rails with safety device in
“locked” and “unlocked» position.• A dial manometer (0 to 1000 Pa scale) by level to indicate the evolution of the clogging and a cover manoeuvre key. • A hole to make it easier to unfold safe change bags.• Connection fl anges, the orientations of which are to be made according to the following pages.• As an option, the casings can be fi tted with Ø 200 inlets for the in situ controlling of effi ciency using a Camfi l special mobile group Isolating dampers with manual locking command on “OPEN” or «CLOSED» position. Version with access door for changing the fl ap gasket without disassembling the damper.
For fi lters: Medium Effi ciency Filters 610x610x50 mm High Effi ciency Filters, VHE and activated carbon fi lters 610x610x292.
Maximum airfl ow: Filter nominal airfl ow.
Temperature: 120°C in continuous service and 200°C in emergency operating for 2 hours.
Controls: Size, appearance, good working order.Visual control of welds. Weld gasket seat leak detection.Overall tightness of the casings under pressure of 3000 Pa according to NFM 62200 class 3. Gasket seat tightness under depression of 1500 Pa, maximum leak airfl ow 10-5 of the casing’s nominal airfl ow.Damper tightness under depression of 3000 Pa, maximum leak airfl ow 10-5 of the casing’s nominal airfl ow. Surface protection.
Assembly: The direction of air fl ow has to be respected in order to not contaminate the work area.• The casings can be stacked and bolted together up to about 5m high.• The dampers have to be installed so that the depression of the circuits pushes the fl ap against the gasket seat to obtain maximum
leak-tightness.
Replacing fi lters:• Sealed, with intervention bags assembled on the lock and using a handling console (see reference below).• Two insulation valves «upstream” and “downstream” will be foreseen to insulate the casing during this operation. If the ventilation
cannot be stopped, the “downstream” damper can be removed.
N.B.: For resistance to seismic or to specifi c operating pressures, please consult us.
Containment equipment
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com 69
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
Intr
oduc
tion
Med
ium
Effi
cien
cyH
igh
Effi c
ienc
yVe
ry H
igh
Effi c
ienc
yAd
sorp
tion
Casi
ngs
and
fi lte
rsfo
r co
ntai
nmen
t sys
tem
sCo
ntai
nmen
t equ
ipm
ent
Equi
pmen
t for
tem
pora
ry v
entil
atio
nAc
cess
orie
s
MULTICELLULAR TYPE TIGHT LOCK CASINGS PAGE 2/4
ADVANTAGES• Single-block casing
• Sealant guaranteed
• Temperature resistance
• Secure fi lter clamping device
• Decontamination
Mild steel casing
Reference
S/Steel casing
Referencex
Max working pressure Pa
Number of fi lters
Airfl ow m³/hmolecular fi ltration particle fi ltration
Pressure Drop Pa*Flange Type 1, 2, 3 ou 4 (see p 72)
Flange positionsUnit
mass kg
Mild steel damper
Reference
S/Steel damper
ReferenceFlangesE1/S1 & E4/S4
FlangesE2/S2 & E5/S5
P P1 H1 H2
CASING FOR FILTER 610x610x292
7140.12.00 7240.12.00 ± 6000 2 24006800
7 40
28160 1 666 368 910.5 200.5 230 7100.12.00 or
7101.12.007200.12.00 or
7201.12.00
7140.13.00 7240.13.00 ± 6000 3 360010200
9 50
36200 2 666 368 1068 253 350 7100.13.00 or
7101.13.007200.13.00 or
7201.13.00
7140.14.00 7240.14.00 ± 6000 4 480013600
8 50
37230 3 668 369 1226.5 306.5 590 7100.14.00 or
7101.14.007200.14.00 or
7201.14.00
7140.15.00 7240.15.00 ± 6000 5 600017000
7 40
32180 4 668 369 1541.5 411.5 830 7100.15.00 or
7101.15.007200.15.00 or
7201.15.00
7140.16.00 7240.16.00 ± 6000 6 720020400
8 50
42260 4 668 369 1541.5 411.5 980 7100.15.00 or
7101.15.007200.15.00 or
7201.15.00CASING FOR FILTER 610x305x292, the casing is equipped with the intermediate gasket fl ange
7160.12.00 7260.12.00 ± 6000 4 24006000
7 40
28160 1 666 368 910.5 200.5 230 7100.12.00 or
7101.12.007200.12.00 or
7201.12.00
7160.13.00 7260.13.00 ± 6000 6 36009000
9 50
36200 2 666 368 1068 253 350 7100.13.00 or
7101.13.007200.13.00 or
7201.13.00
7160.14.00 7260.14.00 ± 6000 8 4800132000
8 50
37230 3 668 369 1226.5 306.5 590 7100.14.00 or
7101.14.007200.14.00 or
7201.14.00
7160.15.00 7260.15.00 ± 6000 10 600013000
7 40
32180 4 668 369 1541.5 411.5 830 7100.15.00 or
7101.15.007200.15.00 or
7201.15.00
7160.16.00 7260.16.00 ± 6000 12 720018000
8 50
42260 4 668 369 1541.5 411.5 980 7100.15.00 or
7101.15.007200.15.00 or
7201.15.00
Material available on order. ACCESSORIES: see page 88.* P : between fl anges, without fi lter, without damper.
Containment equipment
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com70
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
IntroductionM
edium Effi ciency
High Effi ciency
Very High Effi ciency
AdsorptionCasings and fi lters
for containment system
sContainm
ent equipment
Equipment for
temporary ventilation
Accessoires
MULTICELLULAR TYPE TIGHT LOCK CASINGS PAGE 3/4
ADVANTAGES• Single-block casing
• Sealant guaranteed
• Temperature resistance
• Secure fi lter clamping device
• Decontamination
Mild steel casing
Reference
S/Steel casing
Reference
Max working pressure Pa
Number of fi lters
Airfl ow m³/hmolecular fi ltration particle fi ltration
Pressure Drop Pa* Flange Type 1, 2, 3 ou 4 (see p 72)
Flange positions Unit mass
kg
Mild steel damper
Reference
S/Steel damper
Reference
Flanges E1/S1 & E4/S4
Flanges E2/S2 & E5/S5
P P1 H1 H2
CASING FOR FILTER 610x610x292
7140.22.00 7240.22.00 ± 6000 4 24006800
7 40
28160 1 666 368 1395.5 200.5 340 7100.12.00 or
7101.12.007200.12.00 or
7201.12.00
7140.23.00 7240.23.00 ± 6000 6 360010200
9 50
36200 2 666 368 1553 253 500 7100.13.00 or
7101.13.007200.13.00 or
7201.13.00
7140.24.00 7240.24.00 ± 6000 8 480013600
8 50
37230 3 668 369 1711.5 306.5 810 7100.14.00 or
7101.14.007200.14.00 or
7201.14.00
7140.25.00 7240.25.00 ± 6000 10 600017000
7 40
32180 4 668 369 2026.5 411.5 1110 7100.15.00 or
7101.15.007200.15.00 or
7201.15.00
7140.26.00 7240.26.00 ± 6000 12 720020400
8 50
42260 4 668 369 2026.5 411.5 1300 7100.15.00 or
7101.15.007200.15.00 or
7201.15.00CASING FOR FILTER 610x305x292, the casing is equipped with the intermediate gasket fl ange
7160.22.00 7260.22.00 ± 6000 8 24006000
7 40
28160 1 666 368 1395.5 200.5 340 7100.12.00 or
7101.12.007200.12.00 or
7201.12.00
7160.23.00 7260.23.00 ± 6000 12 36009000
9 50
36200 2 666 368 1553 253 500 7100.13.00 or
7101.13.007200.13.00 or
7201.13.00
7160.24.00 7260.24.00 ± 6000 16 480012000
8 50
37230 3 668 369 1711.5 306.5 810 7100.14.00 or
7101.14.007200.14.00 or
7201.14.00
7160.25.00 7260.25.00 ± 6000 20 6000173000
7 40
32180 4 668 369 2026.5 411.5 1110 7100.15.00 or
7101.15.007200.15.00 or
7201.15.00
7160.26.00 7260.26.00 ± 6000 24 720018000
8 50
42260 4 668 369 2026.5 411.5 1300 7100.15.00 or
7101.15.007200.15.00 or
7201.15.00
Material available on order. ACCESSORIES: see page 88.* P : between fl anges, without fi lter, without damper.
Containment equipment
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com 71
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
Intr
oduc
tion
Med
ium
Effi
cien
cyH
igh
Effi c
ienc
yVe
ry H
igh
Effi c
ienc
yAd
sorp
tion
Casi
ngs
and
fi lte
rsfo
r co
ntai
nmen
t sys
tem
sCo
ntai
nmen
t equ
ipm
ent
Equi
pmen
t for
tem
pora
ry v
entil
atio
nAc
cess
orie
s
MULTICELLULAR TYPE TIGHT LOCK CASINGS PAGE 4/4
ADVANTAGES• Single-block casing
• Sealant guaranteed
• Temperature resistance
• Secure fi lter clamping device
• Decontamination
Mild steel casing
Reference
S/Steel casing
Reference
Max working pressure Pa
Nbr of prefi lters
Nbr of fi lters
Airfl ow m³/hmolecular fi ltration particle fi ltration
Pressure Drop Pa* Flange Type 1, 2, 3 ou 4 (see p 72)
Flange positions Unit mass
kg
Mild steel damper
Reference
S/Steel damper
Reference
Flanges E1/S1 & E4/S4
Flanges E2/S2 & E5/S5
P P1 H1 H2
CASING FOR PREFILTER 610x610x50 and FILTER 610x610x292
7150.12.00 7250.12.00 ± 6000 2 2 24006800
740
28160 1 666 368 1176.5 200.5 320 7100.12.00 or
7101.12.007200.12.0 or 7201.12.00
7150.13.00 7250.13.00 ± 6000 3 3 360010200
950
36200 2 666 368 1334 253 440 7100.13.00 or
7101.13.007200.13.00 or
7201.13.00
7150.14.00 7250.14.00 ± 6000 4 4 480013600
850
37230 3 668 369 1492.5 306.5 730 7100.14.00 or
7101.14.007200.14.00 or
7201.14.00
7150.15.00 7250.15.00 ± 6000 5 5 600017000
740
32180 4 668 369 1807.5 411.5 1000 7100.15.00 or
7101.15.007200.15.00 or
7201.15.00
7150.16.00 7250.16.00 ± 6000 6 6 720020400
850
42260 4 668 369 1807.5 411.5 1180 7100.15.00 or
7101.15.007200.15.00 or
7201.15.00CASING FOR PREFILTER 610x305x50 and FILTER 610x305x292, the casing is equipped with the intermediate gasket fl ange
7170.12.00 7270.12.00 ± 6000 4 4 24006000
740
28160 1 666 368 1176.5 200.5 320 7100.12.00 or
7101.12.007200.12.0 or 7201.12.00
7170.13.00 7270.13.00 ± 6000 6 6 36009000
950
36200 2 666 368 1334 253 440 7100.13.00 or
7101.13.007200.13.00 or
7201.13.00
7170.14.00 7270.14.00 ± 6000 8 8 480012000
850
37230 3 668 369 1492.5 306.5 730 7100.14.00 or
7101.14.007200.14.00 or
7201.14.00
7170.15.00 7270.15.00 ± 6000 10 10 600013000
740
32180 4 668 369 1807.5 411.5 1000 7100.15.00 or
7101.15.007200.15.00 or
7201.15.00
7170.16.00 7270.16.00 ± 6000 12 12 720018000
850
42260 4 668 369 1807.5 411.5 1180 7100.15.00 or
7101.15.007200.15.00 or
7201.15.00
Material available on order. ACCESSORIES: see page 88.* P : between fl anges, without fi lter, without damper.
Containment equipment
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com72
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
IntroductionM
edium Effi ciency
High Effi ciency
Very High Effi ciency
AdsorptionCasings and fi lters
for containment system
sContainm
ent equipment
Equipment for
temporary ventilation
Accessoires
MULTICELLULAR TYPE TIGHT LOCK CASINGS CONNECTING FLANGES
ADVANTAGES• High level of fl exibility
ORIENTATION OF CONNECTION FLANGES:
On multi-cell tight lock casings, the fl anges can be positioned in several directions defi ned in the fi gure opposite.
• The delivery duct for the air to be fi ltered will be connected to one of the fl anges E1, E2, E4, E5, the fi ltered air duct is connected to one of the outlets S1, S2, S4, and S5.
• The positioning of the fl anges on a casing will be defi ned by the two symbols corresponding to its fl anges to be given in the order.
• For entry fl anges located on the right of the casing, the exit fl anges must be on the left and vice versa. For example: E1/S1 or E4/S4 etc.
• Arrival on the top of the casing possible: please consult us.
• Circular connection fl anges: please consult us.
CONNECTING FLANGES:
Containment equipment
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com 73
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
Intr
oduc
tion
Med
ium
Effi
cien
cyH
igh
Effi c
ienc
yVe
ry H
igh
Effi c
ienc
yAd
sorp
tion
Casi
ngs
and
fi lte
rsfo
r co
ntai
nmen
t sys
tem
sCo
ntai
nmen
t equ
ipm
ent
Equi
pmen
t for
tem
pora
ry v
entil
atio
nAc
cess
orie
s
ISOLATING DAMPERS
ADVANTAGES• Tightness guaranteed
• Access door: replace the gasket without removing the damper
Used for isolating tight lock casings from the rest of the installation for changing fi lters without stopping ventilation if the casings are bypassed, these dampers are assembled upstream and downstream of the casings.
Damper reference without inspection hatch
Damper reference with inspection hatche A B C D
E without hatch
E with
hatchn p
D without hatch
Airfl ows m³/h P Pa*
Mass kg without hatch
Mass kg with
hatchMild steel S/Steel Mild steel S/Steel
7100.12.00 7200.12.00 7101.12.00 7201.12.00 275 208 361 676 200 435 3 18 89 24006800 25160 34 45
7100.13.00 7200.13.00 7101.13.00 7201.13.00 380 308 466 676 250 540 4 20 147 360010200 1060 42 57
7100.14.00 7200.14.00 7101.14.00 7201.14.00 485 388 571 676 340 615 5 22 156 480013600 1080 55 70
7100.15.00 7200.15.00 7101.15.00 7201.15.00 695 264 781 676 220 450 7 26 147 720020400 20140 68 83
Material available on order.
* P: for 1 damper.
Containment equipment
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com74
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
IntroductionM
edium Effi ciency
High Effi ciency
Very High Effi ciency
AdsorptionCasings and fi lters
for containment system
sContainm
ent equipment
Equipment for
temporary ventilation
Accessoires
SPECIFIC SURFACE TREATMENT FOR CASING WITH SEALED LOCK AND ISOLATING DAMPER
In case of specifi c application, for example, during the conversion or enrichment of fuel for nuclear power plants, certain procedures require equipment that can resist acidic gases.
These gases can be extremely corrosive on “classic” materials, and also dangerous for people and the environment.
Camfi l Farr uses the support of its unarguable experience in nuclear boiler work to develop a material allowing these requirements to be met.
After research, laboratory tests and the making of a prototype, Camfi l Farr today offers an adapted surface treatment.
For example, an ECTFE (Ethylene chlorotrifl uoroethylene) type coating that can withstand extremely corrosive acidic atmospheres.
The implementation of such a coating is made by hot electrostatic application after specifi c thermal and mechanical treatments.
This surface treatment can be made on tight lock casing or isolation dampers made of mild steel or stainless steel.
Photo opposite:Example of multicellular tight lock casing with insideECTFE coating, made up of 3 fi ltration levels:
• Prefi lter
• Very High Effi ciency
• Adsorption
Containment equipment
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com 75
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
Intr
oduc
tion
Med
ium
Effi
cien
cyH
igh
Effi c
ienc
yVe
ry H
igh
Effi c
ienc
yAd
sorp
tion
Casi
ngs
and
fi lte
rsfo
r co
ntai
nmen
t sys
tem
sCo
ntai
nmen
t equ
ipm
ent
Equi
pmen
t for
tem
pora
ry v
entil
atio
nAc
cess
orie
s
PROCEDURE FOR CHANGING FILTERS PAGE 1/3
PROCEDURE FOR REPLACING FILTERS ON AN IN-SERVICE INSTALLATION
What follows concerns replacing VHE fi lters and activated carbon fi lters. For prefi lters, the process is the same with one single camshaft.
Vocabulary linked to the Tight lock casing
Vent
Clamping nuts
Cell
Filtration stage
Clamping system in locked position:
Clamping system in unlocked position: The cranks are taken out and prevent the cover of the cell being closed as long as the fi lter is unlocked.
1. The casing is operating, the dampers or valves are open.
In each cell, the camshaft manoeuvre handles are in the locked position.
2. Close the dampers or the isolation valves or, failing this, stop the ventilation.
3. Open the air inlet (see fi rst fi gure above), the effect of this is to equalise the pressure between the inside and the outside of the casing and thus allow the vinyl containment bags to be deployed
4. Unscrew the clamping nuts then remove the cover.
5. Install the handling console.
6. Through the vinyl bag, unlock the fi lter bag by pulling the handles of the camshafts and putting them in the unlocked position.
Containment equipment
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com76
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
IntroductionM
edium Effi ciency
High Effi ciency
Very High Effi ciency
AdsorptionCasings and fi lters
for containment system
sContainm
ent equipment
Equipment for
temporary ventilation
Accessoires
PROCEDURE FOR CHANGING FILTERS PAGE 2/3
7. Pull the used fi ltering cell in the vinyl bag.
8. Weld the bag between the cell and the lock so that it is sealed. Make 3 parallel welds.
9. Cut off the bag along the middle weld. This prevents the dissemination of the dust located in the safe change bag and reduce it as much as possible.
10. The previous bag was installed on the inside groove of the glove seat with adhesive tape to ensure the tightness. Now there is only a bag stump fi xed to the Casing. Remove the adhe-sive tape…
Containment equipment
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com 77
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
Intr
oduc
tion
Med
ium
Effi
cien
cyH
igh
Effi c
ienc
yVe
ry H
igh
Effi c
ienc
yAd
sorp
tion
Casi
ngs
and
fi lte
rsfo
r co
ntai
nmen
t sys
tem
sCo
ntai
nmen
t equ
ipm
ent
Equi
pmen
t for
tem
pora
ry v
entil
atio
nAc
cess
orie
s
... and gently slide the remaining part of the bag on the outside seam of the glove seat. This allows you to remove this part of the bag inside the new bag.
Glove opening Bag on glove opening inside
11. The new fi lter has to be placed in a bag before being instal-led. Place the new fi lter in its new vinyl bag, the rubber gasket on the gasket seat side and the handle facing the operator. Fix this bag over the previous bag on the free inside seam and hold it in place using adhesive tape.
Extraction sleeve
12. Each new bag is fi tted with a sleeve for removing the rem-nant of the previous bag. Place your arm in the sleeve of the new bag turned inside out, pull off the remnant of the previous bag and pull it towards you so that it is inside the sleeve.
Extraction sleeveContaining the remnant of the previous bag
13. Weld the sleeve in the same way as for the bag, with 3 welds, and remove it after cutting along the middle weld.
14. Push the new cell into the casing until it cannot go any further.
15. Lock the cell by turning the camshafts into the locked
positions.
16. Role the bag and place it inside the lock so that there
are no folds on the glove opening. Replace the cover.
17. Close the air inlet.
18. Open the dampers or the isolation valves or start up the ventilation.
PROCEDURE FOR CHANGING FILTERS PAGE 3/3
Containment equipment
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com78
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
IntroductionM
edium Effi ciency
High Effi ciency
Very High Effi ciency
AdsorptionCasings and fi lters
for containment system
sContainm
ent equipment
Equipment for
temporary ventilation
Accessoires
BAG OUT PORT TYPE PLATFORMS
ADVANTAGES• Guaranteed gasket seat tightness
• Replacement of contaminated fi lters in intervention bags.
• Quick locking of fi lters
Applications: Making fi ltering barriers in high effi ciency, very high effi ciency or activated carbon fi ltration.
Type: Fast blocking sleeve platform.
Description:• Frame made of folded mild steel sheet metal or welded stainless steel.• Plated and welded tight gasket fl ange.• Mild steel sleeves assembled on the platform, after installation, by threaded ties.• Quick locking systems for fi lters (CAMFIL patent) made up of eccentric handles made of zinc-plated bichromate mild steel• Protection by decontaminable paint (mild steel) or by stripping and passivating (stainless steel).
For fi lters: 610x610x292 mm.
Assembly: The platforms are fi xed on the civil engineering part or on the metal casing using clamps.
On request, adaptation for prefi lters can be planned on the opposite side to the fi lters.
Number of fi lters Dimensions mmType *
Painted mild steel platforms Stainless steel platformsUnit mass kg
Total W x H W H References References
1 1 x 1 770 765 A 5443.11.00 5444.11.00 30
2 1 x 2 770 1490 A 5443.12.00 5444.12.00 60
2 2 x 1 1490 770 B 5443.21.00 5444.21.00 60
3 1 x 3 770 2215 A 5443.13.00 5444.13.00 85
3 3 x 1 2215 770 B 5443.31.00 5444.31.00 85
4 2 x 2 1460 1490 A 5443.22.00 5444.22.00 105
6 2 x 3 1460 2215 A 5443.23.00 5444.23.00 150
6 3 x 2 2215 1460 B 5443.32.00 5444.32.00 150
8 2 x 4 1460 2940 A 5443.24.00 5444.24.00 200
8 4 x 2 2940 1460 B 5443.42.00 5444.42.00 200
9 3 x 3 2150 2215 A 5443.33.00 5444.33.00 220
12 3 x 4 2150 2940 A 5443.34.00 5444.34.00 285
12 4 x 3 2840 2215 A 5443.43.00 5444.43.00 285
15 3 x 5 2215 3530 B 5443.35.00 5444.35.00 355
15 5 x 3 3530 2215 A 5443.53.00 5444.53.00 355
16 4 x 4 2840 2940 A 5443.44.00 5444.44.00 380
* Type A: vertical V-pack assembled fi lters – Type B: horizontal V-packs Material available on order.
Containment equipment
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com 79
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
Intr
oduc
tion
Med
ium
Effi
cien
cyH
igh
Effi c
ienc
yVe
ry H
igh
Effi c
ienc
yAd
sorp
tion
Casi
ngs
and
fi lte
rsfo
r co
ntai
nmen
t sys
tem
sCo
ntai
nmen
t equ
ipm
ent
Equi
pmen
t for
tem
pora
ry v
entil
atio
nAc
cess
orie
s
CRADLE PLATFORMS
Applications: Making fi ltering barriers in high effi ciency, very high effi ciency or activated carbon fi ltration.
Type: Cradle platform.
Description:• Frame made of welded mild steel extruded shapes.• Plated and welded tight gasket fl ange.• Filter clamping devices by frames made of mild steel and bolting made of zinc-plated bichromate steel.
For fi lters: 610x610x292 mm and prefi lters 610x610x50mm.
For fi lters: 610x305x292 mm and prefi lters 610x305x50 mm.
The platform is fi tted with intermediary gasket seats.
Assembly:• Platform to be bolted: openings Ø 12 mm are to be counterbored on site on the opposite side from the gasket seat using Ø 10 mm
bolting (not included).• Platform to be sealed: some sealing rounds are foreseen on the edge of the platform.
These platforms can also be made of stainless steel.
ADVANTAGES• Gasket seat tightness guaranteed
• In-series assembly of prefi lters and fi lters
• Planned to resist seismic loads
Number of fi lters Dimensions mm Platforms to bolt Platforms to sealUnit mass kg
Total W x H W H References References
1 1 x 1 726 726 5264.01.00 5266.01.00 23
2 1 x 2 726 1352 5264.02.00 5266.02.00 33
2 2 x 1 1381 726 5264.03.00 5266.03.00 33
3 1 x 3 726 1978 5264.04.00 5266.04.00 52
3 3 x 1 2036 726 5264.05.00 5266.05.00 52
4 2 x 2 1381 1352 5264.08.00 5266.08.00 75
6 2 x 3 1381 1978 5264.13.00 5266.13.00 105
6 3 x 2 2036 1352 5264.14.00 5266.14.00 105
8 2 x 4 1381 2604 5264.15.00 5266.15.00 120
8 4 x 2 2691 1352 5264.16.00 5266.16.00 120
9 3 x 3 2036 1978 5264.17.00 5266.17.00 133
12 3 x 4 2036 2604 5264.22.00 5266.22.00 155
12 4 x 3 2691 1978 5264.23.00 5266.23.00 155
15 3 x 5 2036 3230 5264.24.00 5266.24.00 165
15 5 x 3 3346 1978 5264.25.00 5266.25.00 165
Material available on order.
Containment equipment
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com80
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
IntroductionM
edium Effi ciency
High Effi ciency
Very High Effi ciency
AdsorptionCasings and fi lters
for containment system
sContainm
ent equipment
Equipment for
temporary ventilation
Accessoires
CAM PLATFORMS
ADVANTAGES• Gasket seat tightness guaranteed
• Quick locking of fi lters
Applications: Making fi ltering barriers in high effi ciency, very high effi ciency or activated carbon fi ltration.
Type: Cam platform.
Description:• Frame made of welded mild steel extruded shapes.• Plated and welded tight gasket fl ange.• Systems for clamping fi lters with 2 removable camshafts made of cadmium-plated mild steel ensuring adequate compression of the
gasket.
For fi lters: 610x610x292 mm
Assembly:• Platform to bolt: openings Ø 12 mm are to be counterbored on site on the opposite side from the gasket fl ange using Ø 10 mm
bolting (not included).• Platform to seal: some sealing rounds are foreseen on the edge of the platform.
These platforms can also be made of stainless steel.
Number of fi lters Dimensions mm Platforms to bolt Platforms to sealUnit mass kg
Total W x H W H References References
1 1 x 1 646 646 5251.01.00 5253.01.00 37
2 1 x 2 646 1272 5251.02.00 5253.02.00 60
2 2 x 1 1272 646 5251.03.00 5253.03.00 60
3 1 x 3 646 1898 5251.04.00 5253.04.00 85
3 3 x 1 1898 646 5251.05.00 5253.05.00 85
4 2 x 2 1272 1272 5251.08.00 5253.08.00 100
6 2 x 3 1272 1898 5251.13.00 5253.13.00 135
6 3 x 2 1898 1272 5251.14.00 5253.14.00 135
8 2 x 4 1272 2524 5251.15.00 5253.15.00 170
8 4 x 2 2524 1272 5251.16.00 5253.16.00 170
9 3 x 3 1898 1898 5251.17.00 5253.17.00 180
12 3 x 4 1898 2524 5251.22.00 5253.22.00 230
12 4 x 3 2524 1898 5251.23.00 5253.23.00 130
15 3 x 5 1898 3150 5251.24.00 5253.24.00 280
15 5 x 3 3150 1898 5251.25.00 5253.25.00 280
Material available on order.
Containment equipment
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com 81
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
Intr
oduc
tion
Med
ium
Effi
cien
cyH
igh
Effi c
ienc
yVe
ry H
igh
Effi c
ienc
yAd
sorp
tion
Casi
ngs
and
fi lte
rsfo
r co
ntai
nmen
t sys
tem
sCo
ntai
nmen
t equ
ipm
ent
Equi
pmen
t for
tem
pora
ry v
entil
atio
nAc
cess
orie
s
CAGES
Applications: replacement of 40 and 80 V-pack cages.
Type: cages for VHE fi lters.
Description:• Frames made of welded mild steel extruded shapes 4mm thick.• Plated and welded tight gasket fl ange.• Bottom base with silicon gasket and crushing limiters.• Clamping systems for fi lters by 2 independent stirrups made of mild steel and threaded ties with crushing limiters made of cadmium-
coated bichromate steel.• Protection by decontaminable paint.
For fi lters: 600x325x202 mm.
Temperature: 120°C in continuous service and 200°C in emergency operating for 2 hours.
Controls:Dimensional, appearance, operating.Visual control of welds.State of surface and smoothness of the planes of the fi lter gaskets and the base.Weld gasket seat leak detection.Surface protection.
Assembly: on installation, ensure the good levelling of the sealed foundation and the surface state of its gasket fl ange.
Reference Replacement model Number of fi lters Dimensions mm Unit mass kg Unit volume m³
6953.09.00 80 V-pack cage 16 1615x750x750 152 0.91
6955.06.00 40 V-pack cage 8 785x750x750 95 0.44
6955.16.00 80 V-pack cage 16 1435x750x750 152 0.81
ADVANTAGES• Tightness guaranteed
• Temperature resistance
• Decontamination
• Compatible fi lter CTHEN certifi ed
Containment equipment
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com82
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
IntroductionM
edium Effi ciency
High Effi ciency
Very High Effi ciency
AdsorptionCasings and fi lters
for containment system
sContainm
ent equipment
Equipment for
temporary ventilation
Accessoires
GAS ADSORBERS (SOFILTRAD model)
ADVANTAGES• Safe operating
• Cost savings
• Easy to operate
• 250 devices installed in 30 years
Applications: Trapping toxic gases, like for example radioio-dines.
Type: Gas adsorber with remote pneumatic loading and unloa-ding.
Thickness of activated carbon: From 50 to 200 mm.
Specifi c characteristics:• Safe operating: The operator is not exposed to contamination
during loading and unloading operations. • Cost savings: only the used activated carbon has to be re-
placed and the intervention time is reduced to its minimum.• Easy to operate: the activated carbon is directly sucked into
the delivery drums by a mobile pneumatic transport unit that ensures the continuous loading of the adsorber. When unloa-ding, the mobile unit sucks the carbon that is recuperated into the drums.
• Dust removal from the activated carbon: when loading car-bon the majority of the dust is removed by the dust removal device incorporated into the pneumatic transport mobile unit, the rest of the dust is eliminated by the mobile dust removal unit when entering the adsorber.
Description:SOFILTRAD gas adsorbers are entirely made of X2CrNi18-9 stainless steel. They are assembled by weld without gasket.They are formed by a series of vertical beds in the shape of a diamond, of a thickness that can vary from 50 to 200 mm, outlined by fi nely perforated metal sheet.This set of beds, which makes up the active part of the adsorber is completed by:• at the top, a supply chamber with loading opening;• in the bottom part, a double slope hopper for servicing the
adsorbent and a vibrator to perfect the settling of the activa-ted carbon after loading and facilitate removal at the end of servicing.
SOFILTRAD gas adsorbers comply with CEA and EDF specifi -cations.They can be calculated to resist seismic depending on the par-ticular data of each site.
Mobile groupfor loadingand unloading
Mobile groupfor dust removal
Assembly:SOFILTRAD gas adsorbers can be:• incorporated into equipment with inside access equipped
upstream of prefi lters and VHE fi lters and downstream of VHE fi lters that increase safety by arresting carbon dust likely to be dragged along during operating;
• associated downstream of a tight lock casing equipped with prefi lters and VHE fi lters or downstream of a tight lock casing fi tted with VHE fi lters.
Equipment for temporary ventilation
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com 83
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
Intr
oduc
tion
Med
ium
Effi
cien
cyH
igh
Effi c
ienc
yVe
ry H
igh
Effi c
ienc
yAd
sorp
tion
Casi
ngs
and
fi lte
rsfo
r co
ntai
nmen
t sys
tem
sCo
ntai
nmen
t equ
ipm
ent
Equi
pmen
t for
tem
pora
ry v
entil
atio
nAc
cess
orie
s
CONTENTS
MOBILE FAN FILTER CASINGSFOR NUCLEAR DISMANTLING
page 84p
TYPICAL CONFIGURATIONS
page 85
CURVES
page 86
ACCESSORIES FORDISMANTLING
page 86
Equipment for temporary ventilation
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com84
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
IntroductionM
edium Effi ciency
High Effi ciency
Very High Effi ciency
AdsorptionCasings and fi lters
for containment system
sContainm
ent equipment
Equipment for
temporary ventilation
Accessoires
MOBILE FAN FILTER CASINGS FOR NUCLEAR DISMANTLING
Application:
Contaminated air extraction as close as possible to the pollution source. Adapted to nuclear dismantling worksites and for quick and mobile deployment of the fi ltration system.
Strong points:
Robuste :
Technology from Camfi l Farr nuclear tight lock casings.
Casing made of mild steel sheet metal or stainless steel welded tight with glove opening covered by a cover for access to the fi l-ter and reinforced to withstand the clamping effort of a CTHEN fi lter.
Electric cabinet resistant to impacts, to dust and to water jets.
Protection by paint (mild steel) or by stripping and passivating (stainless steel).
Centrifuge ventilator driven by an induction motor protected from the surrounding environment.
Electricity supply 3 Ph 400V 50Hz.
Weight 300kg without fi lters.
Easy to use:• Airfl ow variation by frequency regulator or by butterfl y
damper.• Manometer to observe the pressure drop evolution• Motor rotation direction guaranteed by a detector of the order
of stages (available with automatic reversing device as an option).
• Air inlet Ø250mm can be disassembled and oriented in four positions.
Safety:• Filter clamped by two camshafts operating on stainless steel
guide rails.• Guaranteed gasket clamping.• Vinyl bags for replacement of contaminated fi lters without
breaking containment.• Guaranteed leak-tightness of the casing when operating.• Uranine effi ciency > 5000 over entire casing with CTHEN
fi lters (Standard NFX 44-011).• Electrical safety, motor protection and operator protection
device.
Filtration adapted to your requirements:
Prefi ltration by metal knit media.
High Effi ciency or Very High Effi ciency Filtration.
CTHEN certifi ed fi lters 200°C/2h.
Molecular fi ltration by activated carbon for fi ltration of gases and trapping iodine.
Filters available as full cell (610mm x 610mm) or half cell (610mm x 305mm).
Mobile:• Prehension lugs.• Directional wheels with brake and handling handle.• Height foreseen to pass under standard doors.• Cable winder 10m (as an option).
Characteristics of the casing above:
Maximum pressure drops upstream: 600Pa.
Prefi lter cell and one fi ltration level can host VHE, CHTEN or Carbon fi lters.
Dimensions: L 990 x l 1000 x H 1950.
Weight: 360kg with fi lters.
Reference: 8170.11.20.
ADVANTAGES• Robust
• Easy to use
• Safe
• Filtration adapted to your requirements
• Mobile
Equipment for temporary ventilation
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com 85
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
Intr
oduc
tion
Med
ium
Effi
cien
cyH
igh
Effi c
ienc
yVe
ry H
igh
Effi c
ienc
yAd
sorp
tion
Casi
ngs
and
fi lte
rsfo
r co
ntai
nmen
t sys
tem
sCo
ntai
nmen
t equ
ipm
ent
Equi
pmen
t for
tem
pora
ry v
entil
atio
nAc
cess
orie
s
MOBILE FAN FILTER CASINGS FOR NUCLEAR DISMANTLING
Selections of references for casings and associated fi lters
Painted steel Reference Nominal airfl ow (m3/h) Regulation Filtration stages Cells size Number of cells per stage
8120.11.10
1500
Damper1 stage fi lter 610x305 1
8120.11.30 Variator
8120.21.10 Damper2 stages fi lters 610x305 1
8120.21.30 Variator
8130.11.10 Damper1 stage prefi lter + 1 stage fi lter 610x305 1
8130.11.30 Variator
8130.21.10 Damper1 stage prefi lter + 2 stages fi lters 610x305 1
8130.21.30 Variator
8140.11.20
3400
Damper1 stage fi lter 610x610 1
8140.11.40 Variator
8140.21.20 Damper2 stages fi lters 610x610 1
8140.21.40 Variator
8150.11.20 Damper1 stage prefi lter + 1 stage fi lter 610x610 1
8150.11.40 Variator
8150.21.20 Damper1 stage prefi lter + 2 stages fi lters 610x610 1
8150.21.40 Variator
8160.11.20
3000
Damper1 stage fi lter 610x305 2
8160.11.40 Variator
8160.21.20 Damper2 stages fi lters 610x305 2
8160.21.40 Variator
8170.11.20 Damper1 stage prefi lter + 1 stage fi lter 610x305 2
8170.11.40 Variator
8170.21.20 Damper1 stage prefi lter + 2 stages fi lters 610x305 2
8170.21.40 Variator
Filter type Filter Reference Bag Reference
610x305 cells
Metal knit prefi lter 1464.11.031900.45.06
Metal prefi lter with baffl es 1465.60.08
VHE fi lter 1505.37.00
1900.46.05Activated carbon fi lter 1625.36.00
CTHEN fi lter 1565.08.11
610x610 cells
Metal knit prefi lter 1460.01.011900.45.06
Metal prefi lter with baffl es 1465.60.03
Filtre THE 1506.37.00
1900.46.05Activated carbon fi lter 1606.36.00
CTHEN fi lter 1560.08.10
Equipment for temporary ventilation
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com86
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
IntroductionM
edium Effi ciency
High Effi ciency
Very High Effi ciency
AdsorptionCasings and fi lters
for containment system
sContainm
ent equipment
Equipment for
temporary ventilation
Accessoires
MOBILE FAN FILTER CASINGS FOR NUCLEAR DISMANTLING
Prefi ltration casing
Ref : 8100.00.01
For installing the prefi ltration spark arrester type barrier upstream of the VHE levels.
A casing allowing the fi lter to be changed quickly.
This is assembled on a guide rail on the cover. The cover is fi xed by quick fasteners.
Thickness of the sheet metal 15/10 with decontaminable coating.
Connection diameter adapted to your installation, to be stipulated at the time of your request.
Handles for easy handling of the casing.
Dimensions of the fi lter: 610x305mm.
Reference of the fi lter to be used:
TM SHOCK 2 in 1, ref.: 1465.60.08, see page 15.
Typical confi gurations
Ventilator curves Airfl ow/Frequency curves on apparatus equipped with a variator
Baffl e box
Ref : 8100.10.01
The baffl e box is a solution that is often used on nuclear worksites. Placed upstream of the fi ltration system it allows sparks from cutting devices to be arrested.
It is made of stainless steel.
The connection diameter is made, on request, at the size used on your installation.
Service
We offer training on using Cam-Protect units as well as support for starting them up.
We also offer you training for maintaining groups and we can provide you with spare parts according to the site maintenance policy.
Accessories for dismantling
Accessories
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com 87
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
Intr
oduc
tion
Med
ium
Effi
cien
cyH
igh
Effi c
ienc
yVe
ry H
igh
Effi c
ienc
yAd
sorp
tion
Casi
ngs
and
fi lte
rsfo
r co
ntai
nmen
t sys
tem
sCo
ntai
nmen
t equ
ipm
ent
Equi
pmen
t for
tem
pora
ry v
entil
atio
nAc
cess
orie
s
CONTENTS
ACCESSORIES
page 88
FILTERING MEDIA Disks and Reels
page 89
MEMORY JOGGERS
page 90
Acronyms and abbreviations
AFNOR Association Française de Normalisation
AHU Air Handling Unit
ASHRAE American Society of Heating, Refrigerating and Air-conditioning Engineers (USA)
ASPEC Association pour la Prévention et l’Etude de la Contamination
BSI British Standards Institute
CEN Comité Européen de Normalisation
CETIAT Centre Technique des Industries Aérauliques et Thermiques
CNC Condensation Nucleus Counter
CSTB Centre Scientifi que et Technique du Bâtiment
DEHS Di-Ethyl-Hexyl-Sebaçate (= DES = DOS)
DIN Deutsches Institut für Normung
DOP Di-Octyl-Phtalate
EUROVENT European Committee of Air Handling and Refrige-ration Equipment Manufacturers
FR Decontamination factor
GRAVI Gravimetric effi ciency
HEPA High Effi ciency Particulate Air (fi lter)
ISO International Standards Organisation
MPPS Most Penetrating Particule Size
OPA Opacimetric effi ciency
ULPA Ultra Low Penetration Air (fi lter)
UNICLIMA Syndicat du matériel frigorifi que, syndicat de l’aéraulique
VOC Volatile Organic Compounds
VTT Technical Research Centre (Finland)
p Pressure drop
MPPS : Most Penetrating Particle Size
The overall effi ciency of an air fi lter results from the combina-tion of the 4 basic mechanisms of fi ltration (settling, inertia, interception and diffusion), the effi ciency curve of an air fi lter usually looks like a “V” when showing minimum effi ciency. This minimum effi ciency corresponds to a particle size called MPPS (Most Penetrating Particle Size).
In other terms, the MPPS is the particle size that is the most diffi cult to stop. Depending on the fi lters and the air passage speeds in the fi ltering media, the MPSS is located between 0.1 and 0.2 µm.
Accessories
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com88
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
IntroductionM
edium Effi ciency
High Effi ciency
Very High Effi ciency
AdsorptionCasings and fi lters
for containment system
sContainm
ent equipment
Equipment for
temporary ventilation
Accessoires
ACCESSORIESSafe change bag, handling console, manometer
Casing type Casing Reference
Safe change bag without ring
Safe change bag with ring
Extended safe change bag without ring (for cell with 2 fi lters 610x305)
Extended safe change bag with ring (for cell with 2 fi lters 610x305
Handling consoleMagnehelic manometer
0 to 1000 Pa
UNIT TIGHT LOCK
CASING
7110.11.001900.43.00 1900.50.00
N/A N/A
N/A
1900.72.02*
7210.11.00
7120.11.00
1900.44.00 1900.49.00
7905.02.00(casing with vertical airfl ow)
7905.03.00(casing with horizontal airfl ow)
7120.21.00
7220.21.00
7220.11.00
7130.11.00
7230.11.00
7140.11.001900.41.00 1900.46.00
1900.78.00 1900.78.01
7905.00.00(casing with vertical airfl ow)
7905.01.00(casing with horizontal airfl ow)
7240.11.00
7150.11.00 1900.40.00 (for prefi lter) 1900.41.00 (for fi lter)
1900.45.00 (for prefi lter) 1900.46.00 (for fi lter)7250.11.00
MULTICELLULAR TIGHT LOCK
CASING
7140.12.00à
7140.16.00
1900.41.00 1900.46.00
7905.00.00
7240.12.00à
7240.16.00
7140.22.00à
7140.26.00
7240.22.00à
7240.26.00
7150.12.00à
7150.16.00 1900.40.00 (for prefi lter) 1900.41.00 (for fi lter)
1900.45.00 (for prefi lter) 1900.46.00 (for fi lter)7250.12.00
à7250.16.00
* Each tight lock casing is supplied with 1 manometer per fi ltration stage assembled and wired.
Accessories
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com 89
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
Intr
oduc
tion
Med
ium
Effi
cien
cyH
igh
Effi c
ienc
yVe
ry H
igh
Effi c
ienc
yAd
sorp
tion
Casi
ngs
and
fi lte
rsfo
r co
ntai
nmen
t sys
tem
sCo
ntai
nmen
t equ
ipm
ent
Equi
pmen
t for
tem
pora
ry v
entil
atio
nAc
cess
orie
s
FILTERING MEDIADisks and ReelsApplications: for measuring and air sampling devices
Type: cellulose or glass fi ber fi ber paper.
PAPER CHARACTERISTICS
Reference Grammage g/m² DOP effi ciency 0.3%m at 1 cm/s Pressure drop at 1 cm/s
Cellulose fi ber paper GREEN 50 45% 15 Pa
Cellulose fi ber paper BLUE 85 65% 35 Pa
Cellulose fi ber paper YELLOW 100 95% 70 Pa
Cellulose fi ber paper PINK 150 99.90% 150 Pa
Cellulose fi ber paper WHITE 80 95% 30 Pa
VHE glass fi ber paper 85 99.99% 75 Pa
PAPER CHARACTERISTICS
Width (m) Length (m) Number of rolls Blue series paper Yellow series paper White series paper
0.04 20 270 3022.01
0.044 65 100 3021.10
0.06 40 108 3022.18
0.07 25 95 3024.21
0.07 40 80 3021.22 3022.22
0.16 80 18 3022.31
0.16 Ext diam 100 50 3022.33
0.80 Ext diam 138 80 3022.37
0.04 65 80 3022.53
Material available on order.
SHAPES AND MODELS/DISKS
Diameter (mm) Min. quantity Blue series paper Yellow series paper Pink series paper White series paper Green series paper
40 to 80 5000 3051.04 to 08 3052.04 to 08 3053.04 to 08 3054.04 to 08 3056.04 to 08
81 to 120 5000 3051.09 to 12 3052.09 to 12 3053.09 to 12 3054.09 to 12 3056.09 to 12
130 2500 3051.13 3052.13 3053.13 3054.13 3056.13
131 to 160 2500 3051.14 to 16 3052.14 to 16 3053.14 to 16 3054.14 to 16 3056.14 to 16
For other models, please consult us.
VHE GLASS FIBER
Diameter Min. quantity Series
130 2500 3056.33
47 1000 3056.40*
* not water resistant.
Accessories
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com90
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
IntroductionM
edium Effi ciency
High Effi ciency
Very High Effi ciency
AdsorptionCasings and fi lters
for containment system
sContainm
ent equipment
Equipment for
temporary ventilation
Accessoires
MEMORY JOGGERSAcronyms and abbreviations
AFNOR Association Française de Normalisation
AHU Air Handling Unit
ASHRAE American Society of Heating, Refrigerating and Air-conditioning Engineers (USA)
ASPEC Association pour la Prévention et l’Etude de la Contamination
BSI British Standards Institute
CEN Comité Européen de Normalisation
CETIAT Centre Technique des Industries Aérauliques et Thermiques
CNC Condensation Nucleus Counter
CSTB Centre Scientifi que et Technique du Bâtiment
DEHS Di-Ethyl-Hexyl-Sebaçate (= DES = DOS)
DIN Deutsches Institut für Normung
DOP Di-Octyl-Phtalate
EUROVENT European Committee of Air Handling and Refrige-ration Equipment Manufacturers
FR Decontamination factor
GRAVI Gravimetric effi ciency
HEPA High Effi ciency Particulate Air (fi lter)
ISO International Standards Organisation
MPPS Most Penetrating Particule Size
OPA Opacimetric effi ciency
ULPA Ultra Low Penetration Air (fi lter)
UNICLIMA Syndicat du matériel frigorifi que, syndicat de l’aé-raulique
VOC Volatile Organic Compounds
VTT Technical Research Centre (Finland)
p Pressure drop
Particle diameterA graph representing the percentage of the spread in number, in area and in weight of the particles present in the atmospheric air depending on the diameter.
MPPS : Most Penetrating Particle Size
The overall effi ciency of an air fi lter results from the combina-tion of the 4 basic mechanisms of fi ltration (settling, inertia, interception and diffusion), the effi ciency curve of an air fi lter usually looks like a “V” when showing minimum effi ciency. This minimum effi ciency corresponds to a particle size called MPPS (Most Penetrating Particle Size).
In other terms, the MPPS is the particle size that is the most diffi cult to stop. Depending on the fi lters and the air passage speeds in the fi ltering media, the MPSS is located between 0.1 and 0.2 µm.
Standards: History
Year Reference Test type Classifi cation
1956 MIL STD 282 DOP 0.3 µm
1972 AFNOR NF X 44.011 Uranine 0.15 µm
1976 EUROVENT 4/4 NaCl 0.35 µm EU10 to EU14
1995 CEN EN 1822 MPPS 0.1 to 0.2 µm HEPA : E10 to H14ULPA : U15 to U17
2009 CEN EN 1822 MPPS 0.1 to 0.2 µmEPA : E10 to E12
HEPA : H13 to H14ULPA : U15 to U17
Conversion table (%)
Effi ciency Penetration FR Effi ciency Penetration FR
95 5 20 99.99 0.01 10 000
99 1 100 99.995 0.005 20 000
99.5 0.5 200 99.999 0.001 100 000
99.9 0.1 1 000 99.9995 0.0005 200 000
99.95 0.05 2 000 99.9999 0.0001 1 000 000
99.97 0.03 3 333 99.99995 0.00005 2 000 000
99.98 0.02 5 000 99.99999 0.00001 10 000 000
Accessories
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com 91
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
Intr
oduc
tion
Med
ium
Effi
cien
cyH
igh
Effi c
ienc
yVe
ry H
igh
Effi c
ienc
yAd
sorp
tion
Casi
ngs
and
fi lte
rsfo
r co
ntai
nmen
t sys
tem
sCo
ntai
nmen
t equ
ipm
ent
Equi
pmen
t for
tem
pora
ry v
entil
atio
nAc
cess
orie
s
Filter effi ciency:
The effi ciency of an air fi lter is expressed in 3 ways:
• The yield (or effi ciency) %
• The permeance (or penetration) %
• The decontamination factor (without dimensions)
It is easy to see that the decontamination factor (DF) is the most representative expression of high fi ltration levels.
N.B. :
I = particle concentration upstream.
E = particle concentration downstream.
MPPS Integral Values MPPS Local Values
Filter group
Filter class
Min. effi ciency
(%)
Max. penetration
(%) Min. FR
Min. effi ciency
(%)
Max. penetration
(%) Min. FR
EPA(E)
E10 85 15 6.7
E11 95 5 20
E12 99.5 0.5 200
HEPA (H)
H13 99.95 0.05 2 000 99.75 0.25 400
H14 99.995 0..005 20 000 99.975 0.025 4 000
ULPA (U)
U15 99.9995 0.0005 200 000 99.9975 0.0025 4 0000
U16 99.99995 0.00005 2 000 000 99.99975 0.00025 400 000
U17 99.999995 0.000005 2 0000 000 99.9999 0.0001 1 000 000
EPA : Effi ciency Particulate Air (fi lter).
HEPA : High Effi ciency Particulate Air (fi lter).
ULPA : Ultra Low Penetration Air (fi lter).
EN/ISO cleanrooms standards applied in Europe
EN ISO 14 644 = particulate + molecular• 1 Air particulate ranking (07/1999)• 2 Follow up (11/2000)• 3 Metrology (03/2006)• 4 Conception, construction, start up (07/2001)• 5 Exploitation (12/2004)• 6 Vocabulary• 7 Isolators, glove boxes, mini environments (12/2004)• 8 Conta molecular ranking (12/2004)
EN ISO 14 698 = bio• 1 Risk areas biocontamination, air methods, surfaces,
textiles, liquids... (03/2004)• 2 bio datas interpretation (03/2004)
Classifi cations of types of air particle cleanliness for clean rooms and areas
Class. No. ISO CD 14644-1
(1996)
Max. permissible concentration (particles/m3 air) in particles of a size equal to or greater than that given below
0.1 µm 0.2 µm 0.3 µm 0.5 µm 1 µm 5 µm
ISO 1 10 2
ISO 2 100 24 10 4
ISO 3 1 000 237 102 35 8
ISO 4 10 000 2 370 1 020 352 83
ISO 5 100 000 23 700 10 200 3 520 832 29
ISO 6 1 000 000 237 000 102 000 35 200 8 320 293
ISO 7 352 000 83 200 2 930
ISO 8 3 520 000 832 000 29 300
ISO 9 35 200 000 8 320 000 293 000
C = 10N(0,1/D)2,08 part/m3.
MEMORY JOGGERS
General Conditions of Sale
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfi lfarr.com92
Cam
fi l F
arr
rese
rves
the
rig
ht t
o m
odify
the
cha
ract
eris
tics
of it
s pr
oduc
ts w
ithou
t pr
ior
notic
e w
ithin
the
fram
ewor
k of
its
cont
inua
l im
prov
emen
t po
licy
for
its p
rodu
cts.
IntroductionM
edium Effi ciency
High Effi ciency
Very High Effi ciency
AdsorptionCasings and fi lters
for containment system
sContainm
ent equipment
Equipment for
temporary ventilation
Accessoires
ARTICLE 1: GENERAL CONDITIONS
Except in case of special agreement, noted in writing, when the client sends an order this implies his agreement, without reservation, to the present sales conditions (GSC), excluding any other documents such as prospectuses, catalogues or website of the seller and which are only given as an indication.The present conditions replace all previous conditions.
ARTICLE 2: OFFER - ORDER
CAMFIL S.A.S reserves the right to unilaterally modify the material that is the object of an order if these modifi cations are linked to the technical or statutory development of products offered by suppliers in particular as far as all modifi cations to layout, shape, dimensions or in terms of materials is concerned.Except if indicated otherwise, the terms of the offer are valid for one month.The seller declares supplying material that complies with the standards of the European Community and declines all responsibility if the said material is used outside the EEC.
ARTICLE 3: STUDIES AND DRAFTS - CONFIDENTIALITY
Except if they are the object of a sales contract, the studies and documents of any kind submitted or sent by CAMFIL always remain its full property and have to be returned on request. In any case, they cannot be sent, reproduced, copied or executed without written authorisation.They in no case constitute a contractual document.
ARTICLE 4: ACCEPTANCE
Acceptance is made by sending CAMFIL acknowledgment of receipt of the order.Any order is considered to be accepted by the parties 72 hours after sending our acknowledgment of receipt of the order.Any accepted order defi nitively binds the client to respect, in particular, the present conditions.
ARTICLE 5: PRICE OF THE GOODS
The products are supplied at the prices in force at the time when the order is placed. They are net, before tax, without packaging, ex-works of the seller.The prices set by quotation are valid for 30 days. In case of an order resulting in a delivery deadline of over 1 month, the prices set on ordering are given as an indication and will be defi nitively given at the time of delivery.
ARTICLE 6: PAYMENT
6.1. Our goods is payable without a discount to the domicile of the seller.The delivery of goods in the sense of article 9-1 of the present brings about the issuing of the invoice. The invoice is established on the day of delivery and its amount can be demanded on this date.The full VAT amount will be demanded on delivery.6.2. In no case can payments be suspended or be the object of any kind of compensation without the prior written agreement of the seller.6.3. Billing minimum: considering the high costs of establishing invoices with a low amount, orders of a total amount of less than 150 Euros before tax, will be invoiced at a minimum price of 150 Euros before tax.6.4. Financial guarantee requirement: Any deterioration in the fi nancial situation of the purchaser could justify requesting guarantees or payment in cash, before processing the orders received.6.5. Unless in case of express agreement, invoices are payable:For series material, with an execution deadline of less than 3 months: 100% by bank transfer 30 days from the invoice issue date and with all taxes.For special or modifi ed material or for any order of an amount higher than 15,000 Euros: 30% on order before tax by cheque or bank transfer and the balance by cheque or bank transfer after 30 days from invoice issue date with all the VAT.
ARTICLE 7: RESERVATION OF OWNERSHIP
Acceptance of delivery or documents relating to this delivery is considered as accepting the present clause.7.1. The seller maintains ownership of the goods sold until actual payment of the total price in principal and accessories in accordance with law 80.335 dated 12 05 1980, the payment being considered as the actual cashing of the sums due. Payment default on any of the payment deadlines could bring about the claiming of the goods.
The client is the guardian of the goods sold under reservation of ownership and accepts risks as of delivery. Therefore, he will have to separately store them in order to identify them as belonging to CAMFIL in case of claim, insure them and accept any responsibility as of delivery.7.2. The client is authorised, within the normal operating framework of his establishment, to resell the goods delivered. He undertakes to inform his own customers that the goods resold is the object of an ownership reservation clause benefi ting CAMFIL.in case of payment incident, this authorisation is automatically void.If payment is not made by the foreseen deadline, CAMFIL reserves the right to take back the products it has delivered at the client’s costs.In case of seizure, or any other intervention of a third party concerning the goods, the purchaser must inform the seller of this immediately so that he can oppose this and uphold his rights.7.3. If the goods have been resold, the client subrogates CAMFIL, in all its rights, to the sub-purchaser. The Client will send, in order to do this, on fi rst request, the names and addresses of the third parties to whom he has resold the goods.
ARTICLE 8: DELAY – PENAL CLAUSE
8.1. All transportation and handling operations, made on site, except in case of particular agreement in the contract, are at the charge, costs and risks of the purchaser who will take out the necessary insurance.8.2. In case of dispatch by Camfi l, dispatch is made carriage forward at the lowest rates, except in case of express request from the purchaser.8.3. In all cases, it is up to the purchaser to control the shipments on arrival and to make a claim, if necessary, against the transporters.
ARTICLE 9: DELIVERY
9.1. The delivery is made available in the CAMFIL warehouses for the goods ordered. 9.2. DEADLINE: The delivery deadlines indicated in the quotations and contracts start from the time when the order has been technically defi ned, when all the information due by the client has been sent and the fi rst deposit has been received, if needed, this the event one of these items is missing, the seller is released ipso jure for any commitment or responsibility relating to the availability deadlines.The purchaser is obliged to pick up the goods delivered by the deadlines set in the order acknowledgment of receipt. Storage fees will be invoiced if the goods have not been picked up within 8 days at a level of 0.5% by week of the price before tax of the goods. The storage and handling of the goods made available will be carried out at the costs and risks of the client.The delivery date is given as an indication only and any delay cannot justify either a request for compensation or the cancellation of the order.9.3. PLACE: The seller’s warehouse is the place of delivery. The purchaser is bound to directly pick up the goods that are the object of the order or have them picked up by one of his authorised representatives from our warehouses.9.4. RISK TRANSFER: The transfer of risks for the products is made from delivery (art. 9-1).9.5. PACKAGING: The packaging is to be paid for by the purchaser. The packaging is prepared by CAMFIL who acts in the best interests of the purchaser. The packaging is only simple mechanical protection against emergency impacts.
ARTICLE 10: TRANSPORTATION
10.1. COSTS: Transportation costs, packaging costs and all related costs, in particular for loading and unloading are to be fully met by the purchaser unless there are provisions to the contrary.10.2. RISK: The goods are always transported at the risks of the purchaser who will take out the necessary insurance. It will be up to him to control the shipments on arrival and to make a claim and reservations, if necessary, against the transporters within 24 hours from receipt of the goods (reservations on the shipping bill and registered letter with acknowledgment of receipt within 48 hours).
ARTICLE 11: DEFINITIVE RECEIPT - COMPLIANCE
Defi nitive receipt will be considered to be made 8 days after the delivery date in the sense of article 9-1. Without prejudice to actions to be taken towards the carrier company, any claim concerning conspicuous defects or concerning non-compliance of the product delivered have to be made in writing within 8 days from the day of delivery.After this deadline, no claim for non-compliance will be accepted by CAMFIL.
Any return of products that do not comply with the order will have to be the object of an express prior written agreement from CAMFIL. The returned products have to be in perfect condition and in their original packaging. The accepted return of products recognised as being non-compliant by CAMFIL will give rise to the free replacement of the product at the costs of CAMFIL, not including shipping and labour costs and excluding any compensation or damage and interest.
ARTICLE 12: CONTROLS AND TESTS
Tests can be made at the request of the purchaser, in the factory, before delivery; the costs in this case will be at the charge of the purchaser.
If, after delivery, the purchaser contests the characteristics or performance of the material, he could ask that measures are taken by CAMFIL, on site, if the operation is possible. In this case, the purchaser will meet the costs incurred by CAMFIL, if the performances and characteristics are compliant with the technical sales conditions, if these are not available, compliant with the standards in force, and in the absence of standards, in accordance with the rules of the profession or good manufacturing practices and with reference to the conditions specifi ed by the manufacturer.
ARTICLE 13: GUARANTEE
The products sold by CAMFIL are guaranteed for 1 year from the delivery date not including consumables and under normal conditions of use.
CAMFIL S.A.S cannot guarantee the lifetime and the effi ciency of the fi lter as regards the environment in which it is installed.
For this guarantee and after expert opinion from its technical department, CAMFIL is limited to replacing faulty products. This guarantee does not cover labour costs or those resulting from disassembly and reassembly operations or other services. It is exclusive of all material or immaterial damage and interest.
The guarantee is not applicable if the deterioration cannot be directly put down to the normal use of the product or when a third party has been involved.
ARTICLE 14: RESPONSIBILITY
CAMFIL FARR cannot, in any case, be held liable if its products are implemented by a third party.
It is expressly agreed between the parties, that the seller’s liability arising from a malfunction or defect from of the delivered goods is limited according to the previous article, as far as hidden defects are concerned especially hidden fl aws and intangible damages.
CAMFIL FARR cannot, in any case, be held liable for a development risk of a legal nature or in case of the occurrence of a Force Majeure. By case of Force Majeure, the following are in particular meant: fl ood, seism, storm, act of war, terrorism, natural disasters and generally, any fortuitous, unforeseeable and unstoppable event.
ARTICLE 15: CANCELLATION
Any request for cancellation of an order should be expressly accepted by CAMFIL and will automatically bring about payment of a penalty that will vary between 30% and 100% of the order at the discretion of CAMFIL depending on the deadline by which this cancellation is asked for.
No cancellation will be granted for an order of special products.
ARTICLE 16: DEFEASANCE CLAUSE
In case of non-execution of all or part of its obligations by the client, the present contract will be terminated ipso jure for the benefi t of the other party without negatively affecting the damages and interest that could be claimed from the client.
Termination will come into force 8 days after sending a warning which has remained unanswered.
ARTICLE 17: COMPETENCE - DISPUTE
In case of dispute, the Commercial Court of Nanterre, applying French law, will be the only competent court, whatever the place of delivery, the method of payment accepted and even in case of the introduction of third parties of multiple defendants.
The French version of these conditions is the only one with contractual value.
For international request
Sandra MOLIÈRECustomer Service Group ResponsibleTel. +33 (0)1 46 52 48 18sandra.moliere@camfi l.fr
Arthur LEPIVERTProduct ManagerTel.+33 (0)1 46 52 49 66arthur.lepivert@camfi l.fr
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - FranceTel. +33 (0)1 46 52 48 00 - Fax +33(0)1 47 60 17 81 - www.camfi lfarr.com
Protection and Safetya sales team at your service…
... and a technical team with 4 Protection and Safety engineers
1 Chemical engineer6 Design Offi ce technicians
Camfil Farr77 / 81 boulevard de la République
FR - 92257 La Garenne Colombes CedexTel. + 33 (0) 1 46 52 48 00Fax + 33 (0) 1 47 60 17 81
20
10
- ju
in
www.camfilfarr.com
The Camil Farr group standards’…
...Camfil Farr is the global leader in clean air technology and energy efficient air filter solutions with product development, R&D and local representation in America, Europe and in the Asia-Pacific region.
We supply high-quality products and services with the aim of making our customers operations more sustainable, energy efficient and productive.
Our own vision of sustainability is a global approach combining consideration for people, environmental protection and business performance.
Camil Farr is a member of the United Nations Global Compact program and follows the GRI (Global Reporting Initiative) sustainability reporting framework.
Cam
fil F
arr
201
2-01
Camfi l Farr Products and Services
Air fi ltration solutions for nuclear industry
Camfi l Farr - clean air solutions
Cam
fil Farr - Safety and P
rotection Catalogue
Safety and Protection