NUCLEAR QUALIFIED ACTUATORS

Electric actuators for Nuclear Power Plants

Page 2: NUCLEAR QUALIFIED ACTUATORSimg65.chem17.com/2/20151123/635839108356808023160.pdfQUAL/1997/8657b). L.Bernard maintains also the nuclear quality in accordance with ISO 9000, 50C/ SG–Q–IAEA

2

2

Page 3: NUCLEAR QUALIFIED ACTUATORSimg65.chem17.com/2/20151123/635839108356808023160.pdfQUAL/1997/8657b). L.Bernard maintains also the nuclear quality in accordance with ISO 9000, 50C/ SG–Q–IAEA

3

Contents

L. BERNARD - electric actuator specialist . . 4

L.Bernard in nuclear plants . . . . . . . . . . . . . . . 5

Type of operation . . . . . . . . . . . . . . . . . . . . . . 6

Nuclear Classification of electric actuators . . . 7

Wide choice of controls . . . . . . . . . . . . . . . . . 8

Overview of SN series - Qualified multiturnactuators for inside containment . . . . . . . . . 10

- SN Qualification description . . . . . . . . . . . . . . . . . . . . . . . 11- SN Performance data . . . . . . . . . . . . . . . . . . . . . . . . . . . 12- SN Dimensions & specifications . . . . . . . . . . . . . . . . . . . 14

Overview of ST series - Qualified multiturnactuators for outside containment . . . . . . . . 16- ST Qualification description . . . . . . . . . . . . . . . . . . . . . . . 17- ST Performance data . . . . . . . . . . . . . . . . . . . . . . . . . . . 18- ST Dimensions & Specifications . . . . . . . . . . . . . . . . . . . 20

Overview of SD series - Qualified quarter- turnactuators for outside containment . . . . . . . . 24

- SD Qualification description . . . . . . . . . . . . . . . . . . . . . . 25- SD Performance data . . . . . . . . . . . . . . . . . . . . . . . . . . 26- SD Dimensions & Specifications . . . . . . . . . . . . . . . . . . . 28

ISO 5210 Guidelines . . . . . . . . . . . . . . . . . . . 32

Other actuation solutions for nuclear powerplants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

Page 4: NUCLEAR QUALIFIED ACTUATORSimg65.chem17.com/2/20151123/635839108356808023160.pdfQUAL/1997/8657b). L.Bernard maintains also the nuclear quality in accordance with ISO 9000, 50C/ SG–Q–IAEA

Certification

L. Bernard appreciates the importance on quality at allstages of the production process, and has put in place andmaintains a Quality Management System in accordancewith ISO 9001-2000 (certification no.:QUAL/1997/8657b). L.Bernard maintains also the nuclearquality in accordance with ISO 9000, 50C/ SG–Q–IAEAcodes and RCCE Chapitre A5000.

The quality of Bernard products has been approved andrecognized by a number of international certifying bodies, including ABS, CSA, NEMA, ATEX, IEEE,LCIE, Germanischer Lloyd, GOST Russia, INERIS andothers.

Services

Our certified technical centres ensure that quality techni-cal support is on hand for all of our customers.

Installation and commissioningThe process of commissioning electric actuators calls forspecial expertise, particularly in cases where themotorized valve is controlled by a complex system like afieldbus.Our specialists can therefore provide assistance to ourcustomers in the following operations:• fitting the actuator to the valve• installation• set-up• commissioning

Maintenance and repairsOur technicians can visit your site at any time to:• conduct periodic checks on the operation of actuators• perform preventive maintenance• troubleshoot problems and carry out repairs

TrainingWe arrange training sessions for our customers on a regularbasis. The sessions can either be held at our head office inFrance or on site.

Subjects which are most in demand include actuatortechnology, settings, operation and maintenance.

4

With several decades of experience in actuator technology and unrivalled knowledge in the use ofthese systems in industry, L.Bernard is ideally placed to offer comprehensive solutions for valve automation applications.

4

Innovation & international presence

L. Bernard is an international company which specializes in thedesign and manufacture of electric actuators and employs aninnovative development program to bring constant improve-ment to its product range.

The company's actuators incorporate the latest design conceptsand specifications to ensure that they are both easy to use andmeet the most demanding industrial standards and environmen-tal requirements.

Over forty subsidiaries, offices and agencies help our customers with the design, installation, commissioning and main-tenance of their systems.

Our flexible approach and efficient service allow us to develop andmaintain a relationship of trust with our customers.

L.BERNARD,the electric actuator specialist

Page 5: NUCLEAR QUALIFIED ACTUATORSimg65.chem17.com/2/20151123/635839108356808023160.pdfQUAL/1997/8657b). L.Bernard maintains also the nuclear quality in accordance with ISO 9000, 50C/ SG–Q–IAEA

5

Important elements in the chain of control, the actuators provide the interface between the commandsystem and the valves, which are essential for regulation and safety in the nuclear power plants.

L.BERNARD,in the nuclear plants

Reliability and safety

Actuator construction requires both electrical and mecha-nical components. Once installed in the heart of thenuclear power plant, they must retain their integrity andremain available, not only during the decades of normalservice in the containment area (in presence of ionisingradiations) but also in case of severe accidental circum-stances when their correct operation becomes absolutelynecessary.

International standards

These environmental conditions have been preciselydefined by the various safety authorities for instance RCCE(French standard), IEEE (American standard) or KTA(German standard).

Accidental circumstances include earthquakes and condi-tions linked to a loss of coolant.

Applications experience

Based on our experience in the nuclear industry (morethan 70 reactor units in operation all over the world),L.Bernard has designed a full range of actuators for useinside and outside nuclear power plants containment. We also propose actuation solutions for other nuclear sitessuch as waste treatment and uranium enrichment plantsor nuclear submarines which carry small nuclear plants onboard. In this last application, compactness is of criticalimportance.

Classification

BERNARD range of electric actuators for nuclear plant hasbeen designed and qualified according to RCC-E standardpublished by AFCEN (French association for the rules ofdesign and construction of components used in nuclearpower plants) and to IEEE.

The RCC-E and IEEE documents specify the rules fordesign, qualification and construction of electical materialsfor nuclear power plants.

Three main levels of requirements and qualification existdepending on the type of application. Please note that these three types of application exist in allstandards but may be named differently.

The three levels of requirements are:

• Non safety requirements (NC) :

actuators designed for operation in normal environmentfor 30 years (referred as “NC” type in the RCC-E stan-dard)

• Safety requirements outside containment (Nuc OC):

actuators designed for operation in normal environmentfor 30 years and during seismic accidents (referred as“K3” type in the RCC-E standard)

• Safety requirements inside containment (Nuc IC):actuators designed for operation during 40 years in ioni-zing environment and remaining operational in case ofseismic accidents and LOCA, Loss of Coolant Accident(referred as “K1” type in the RCC-E standard)

Page 6: NUCLEAR QUALIFIED ACTUATORSimg65.chem17.com/2/20151123/635839108356808023160.pdfQUAL/1997/8657b). L.Bernard maintains also the nuclear quality in accordance with ISO 9000, 50C/ SG–Q–IAEA

CEI 34 STANDARD - S4 Motor duty cycle

S4 INTERMITTENT DUTY WITH STARTINGRepetition of cycles including:• starting period D• period of constant speed N• rest period RTo be followed by the duty factor in %, as well as the number of starts per hour.

The choice of a type of operation determines the selection of a motor for each function. Based on the CEI34 Standard defining the electric motors standard duty cycles, L. Bernard has chosen the S4 dutyrating, because it is the most representative duty cycle for actuators operations.

Type of operation .................................................Modulating class

Open or close the full stroke, ..........................................................................On-Offon average 20 to 30 times/day.360 motor starts / h maxi (peak)Motor duty cycle: S4 - 30% or 40%

Select intermediate positions, ....................................................CLASS III modulatingwith good precision (better than 2 %) on average 360 times/day. 1200 motor starts / h maxi (peak)Motor duty cycle: S4 - 50%

Select intermediate positions, ................................................... CLASS II modulatingwith high precision (better than 1 %) on a permanent basis every 2 or 3 seconds. 1800 motor starts / h maxi (peak)Motor duty cycle: S4 - 100%

Fast positioning ...........................................................................CLASS I modulatingwith an excellent precision (0.5 % or better) and continuous movement.No limit of motor startsMotor duty cycle: S4 - 100%

Type of operation

What are the classes of modulating?

A modulating actuator has to be fully adapted to the operating duty of the modulating loop. Two points are impor-tant for enhancing the reliability of the actuator:• The lifetime of equipment is related to the number of operations (motor, mechanism, electronic…) or to the

change of positions,• The motor must stand up to overheating.

Although the electric motor is important, it is not the only one element to take into account when choo-sing an actuator. Therefore, L.BERNARD proposes a classification of actuators according to four types ofoperations named MODULATING CLASSES.

6

Page 7: NUCLEAR QUALIFIED ACTUATORSimg65.chem17.com/2/20151123/635839108356808023160.pdfQUAL/1997/8657b). L.Bernard maintains also the nuclear quality in accordance with ISO 9000, 50C/ SG–Q–IAEA

7

Nuclear Classificationof electric actuators

Safety related equipement

MULT

I-TU

RN

QUA

RTE

R-T

URN

FAIL

SAFE

SN

ST

MAMB

OANo torque

limiter

Up to 150 N.m

AS/BSTorquelimiter

Up to 1200 N.m

FQ

Electroniccontrol

-

-

-INTELLI+

INTEGRAL+-

INTELLI+POSIGAM+

-INTELLI+

MODUGAM+

-INTELLI+

-INTEGRAL+

-POSIGAM+

-INTELLI+

INTEGRAL+-

INTELLI+POSIGAM+

-INTEGRAL+

-POSIGAM+

GEAR

BOXE

S

ON/OFF

Class III

ON/OFF

Class III

Class II

Class I

ON/OFF

Class III

ON/OFF

Class III

ON/OFF

Class III

Multi-turn

Quarter-turn

Manual

Non safety relatedequipment

NC

-

-

(1)

(1)

Nuc O.COutside containment

qualification(aging & seism tests)

(2)

(2)

-

-

-

(3)

-

(1)

-(1)

Nuc I.CInside containmentqualification (agingseism & LOCA tests)

Linear thrust units are also available(1): separated box only(2): due to the qualification for inside containment, actuator is automatically qualified for outside containment and non safety related area (3): Westinghouse actuator qualification and L.Bernard electronic qualification with separated box

Actuators

The following table shows which actuator types are qualified for each application.

Modulatingclass

Page 8: NUCLEAR QUALIFIED ACTUATORSimg65.chem17.com/2/20151123/635839108356808023160.pdfQUAL/1997/8657b). L.Bernard maintains also the nuclear quality in accordance with ISO 9000, 50C/ SG–Q–IAEA

Wide choice of controlsYou can decide on local or remote control to meet the requirements of your particular system and the environment in which the actuators are to be used. The BERNARD wide range of control systems enables youto choose the best solution for your needs.

As well as the functions offered by INTEGRAL+, theINTELLI+ system also allows the system to be set up and programmed without opening the unit. It includes anLCD screen plus tools for preventive maintenance.

Qualification : Non Safety Related Area

The customer provides the control logic to handle all thedata received from the actuator electric contacts. Thereversing starters are housed in the customer's own enclosure.

Qualification : inside or outside containment, or NonSafety Related Area

The INTEGRAL+ control system is fully configurable and canperform all actuator control functions, including productionof status reports, fault handling, protection systems andcommand processing. Local controls can be disabled eitherlocally or from a remote location. The reversing starters areincorporated in the control unit.

Qualification : outside containment or Non SafetyRelated Area

Fieldbus systems are compatible with L.Bernard integratedcontrols and allow you to control a large number ofactuators or other devices and transmit/receive a greatdeal of data over a single two-wire serial link.Qualification : Non Safety Related Area

Standard version

INTEGRAL+ control

INTELLI+ control

Fieldbus control

BBeenneeffiittss ooff iinntteeggrraatteedd ccoonnttrrooll ssyysstteemmss

• Simple: ready-to-use turnkey solution.• Safe: proven system incorporating many safety features.• Economical: saves time and money at the design and installation stages.• Intelligent: remote management of a large volume of data and optimized preventive maintenance using

our digital solutions in conjunction with the fieldbus.

8

See the "Specifications" section of this brochure for further details.

Page 9: NUCLEAR QUALIFIED ACTUATORSimg65.chem17.com/2/20151123/635839108356808023160.pdfQUAL/1997/8657b). L.Bernard maintains also the nuclear quality in accordance with ISO 9000, 50C/ SG–Q–IAEA

9

QU

ALI

FI-

CATI

ON

FIEL

DB

US

MODULA

-TI

NG

CLA

SSR

EMO

TE C

ON

TRO

LIN

TER

NA

LP

RO

TECT

ION

SIG

NA

LLIN

GM

ON

ITO

RIN

GCO

NFI

GU

RA

TIO

NLO

CAL

COM

MAN

DS

ON/OFF

Modulating class III

Pulse commandMaintained signalESD (Emergency ShutDown)Auxiliary

Timer

Lockable selector knobsDigital displayIndicator lights

FusesAutomatic phase monitoring (3-phase)Motor thermal cut-outTorque limiter protection

Number of signal relaysData itemsNumber of fault relays

Number of listed faultsAnalogue position feedback

Configuration setting

Torque/position setting methodTravel limit stop

Full configuration upload

Self-diagnostics

Torque / position curve

Actuator operating log

Partial stroking

Profibus DP (single or redundant)Foundation fieldbusModbus RTU

INTEGRAL+ INTELLI+

Integral+

Posigam+

(Overrides local command)

Option

-Option

4 + 3 (option)1618

Option (Std on Posigam)

Internal (with jumpers)

MechanicalOn positionOn torque

-

-

---

Option--

Intelli+

Intelli+

2 commands9 options

4 + 3 (option)231

12Option

ExternalLocal command knob

FieldbusPocket PC

LaptopDigital

On positionOn torqueVia fieldbus

Via pocket PCVia laptop

OptionOptionOption

See INTEGRAL+ (A115) and INTELLI+ (A116) catalogues for further information on controls.

Non Safety Related Area

Outside containment

Inside containment

Page 10: NUCLEAR QUALIFIED ACTUATORSimg65.chem17.com/2/20151123/635839108356808023160.pdfQUAL/1997/8657b). L.Bernard maintains also the nuclear quality in accordance with ISO 9000, 50C/ SG–Q–IAEA

10

Overview of SN series

The SN series is a multi turn series designed for inside containment safety-related service (Nuc I.C). It can be used for On-Off or Modulating Class III applications. This range integrates the feedback from users working in more than70 reactor units all over the world.

• High starting torque asynchronous motor

• Excellent starting torque over nominal torque ratio

• On/Off operation: 40% motor duty rating with peakservice conditions up to 360 starts per hour

• Modulating class III: 50% motor duty rating with peakservice conditions up to 1,200 starts per hour

• Motor easy to remove with intermediate connector

Power

Handwheel without clutch release

• Patented manual override system

• Differential geardrive allows the handwheel to beoperated without releasing a clutch beforehand (exceptfor very low torque values on model SN6L).

• The handwheel can therefore be operated under all condi-tions, even when a high torque is applied to the valve (i.ewedge gate valve closed tight)

• Priority of electric command over handwheel manoeu-ver

• Self-locking gearings at all speeds

• Continuous gear drive from the motor down to the valve

• Class H insulation motor

• Unaffected by vibrations

• No preventive maintenance required. Gearing islubricated for lifetime

Mechanical

Sensors

• Torque and position directly and mechanically measured atthe output shaft to accurately reflect the status of the valve

• Dynamometric torque measurement principle usingcalibrated springs mechanically linked to the outputshaft. This torque limiting system ensures a very goodrepeatability, low long-term drift and extremely shortresponse time. The torque sensor fast response enables the controlsystem to cut off the motor supply rapidly, thus limitingthe overtorque applied to the valve

• Travel limit switch setting : easy and reliable in positionand depth

• Torque limit switch setting : easy and reliable with visualindicator and without any special tools

Maintenance

• Modular design to reduce exposure to radiation

• Tightness testing device allows to check, on the spot,for the actuator proctection after any connection ormaintenance operation

• Common control box from SN6 to SN220

Connection

• Pluggable connector with two configurations:- Bernard common control and power connector (from

SN6L to SN220)- Bernard separated connectors for control (plug-in 30

points with earth terminal for shielding) and power (plug-in 4 points including earth terminal)

• Auxiliary terminals available allowing the remote monito-ring of power connector disconnection in the case of adual connectors configuration

• External earth terminal

• Direct connection of large power cables up to 4 x 35mm²

• Connectors have been designed to prevent any pene-tration of water steam from the cables (creepage distance,condensates removal, …)

Qualified multiturn actuators forinside containment (Nuc IC)

Page 11: NUCLEAR QUALIFIED ACTUATORSimg65.chem17.com/2/20151123/635839108356808023160.pdfQUAL/1997/8657b). L.Bernard maintains also the nuclear quality in accordance with ISO 9000, 50C/ SG–Q–IAEA

11

SN Qualification description

SN series qualification program uses an envelop covering both RCC-E and IEEE qualification requirements. For example, pressurization cycle is a test required only by the IEEE standard which was integrated into the SN series qual-ification program.

(*) with 50% of maximum load

Additional tests to reach IEEE levels for radiation and LOCA tests.

Tests were witnessed by an independent third party company : Bureau Veritas.

These products meet the requirements of EPR and non-EPR nuclear power stations. They have been qualified inaccordance with:• RCC-E (2005) - Design and Construction Rules for Electrical Components of Nuclear Islands

• IEEE Std 382 (1996) - IEEE Standard for qualification of actuators for power-operated valve assemblies with safety-relatedfunctions for nuclear power plants

X

X

X (*)

X (*)

X (*)

X (*)

Qualification program SN qualification Operation during the test

Thermal aging 40 years at 40°C

Damp heat test 2 cycles of 24h following EN 60068-2-30 standard (variante 2)

Pressurization cycle 15 cycles 4,48bars (0-65psig)

Functional test 2,000 cycles ON/OFF200,000 steps MODULATING

Vibration aging Up to 2g, 5-500-5Hz, 90min on each axis

Seismic test OBE : up to 3g, 1-40-1HzSSE line mounted : up to 4,5g, 2-32HzSSE Hard mounted : up to 20g, 1-60H

Atmosphere spray Saturated air and steam mixture with chemical spray (0.102lps/m2) composed of boric acid 1.5% andsodium hydroxide 0.6% (pH 9.25 at room temperature)

Radiation 850kGy at 70°C

DBE LOCA test LOCA RCC-E standard (2 peaks of 156°C; 5,6 bars abs)

X (*)

X (*)

Qualification program SN qualification Operation during the test

Atmosphere spray Saturated air and steam mixture with chemical spray(0.475lps/m2) composed of boric acid 1.146%and sodium hydroxide 0.17% (pH 10.5 at room temperature)

Radiation 1050kGy at ambiant temperature

DBE LOCA test Case III of IEEE382

Page 12: NUCLEAR QUALIFIED ACTUATORSimg65.chem17.com/2/20151123/635839108356808023160.pdfQUAL/1997/8657b). L.Bernard maintains also the nuclear quality in accordance with ISO 9000, 50C/ SG–Q–IAEA

12

SN Performance dataPerformance data are given for a 400VAC-50Hz and a 460VAC-60Hz hree phase voltage supply.Please consult us to get precise values at other power supplies, maximum voltage drop, etc ...

(1) Maximal actuator output torque in abnormal conditions with torque limit system out of service (with transient speedof the motor of about 1,200 rpm). Actuator with 1,500 rpm motor type are available in both On-Off and Class III Modulating version.

400V 50Hz

Actuator Speed Guaranteed Minimum Stall (1) Stall torque Motor torque at torque torque at at 0,85Un P Speed Current Current cos0,85Un limiter 1,05Un 156°C nominal Motor nominal starting ϕϕ Efficiency

settingType turns/min Nm Nm Nm Nm kW turns/min A A %

SN6L 11 60 15 134 71 0,06 1500 0,2 0,9 0,63 69SN6L 16 30 5 74 39 0,06 1500 0,2 0,9 0,63 69SN6LS 16 60 5 149 78 0,1 1500 0,4 1,6 0,53 68SN6L 26 20 5 51 27 0,06 1500 0,2 0,9 0,63 69SN6LS 26 60 5 101 53 0,1 1500 0,4 1,6 0,53 68SN6L 61 25 5 46 24 0,1 1500 0,44 0,9 0,53 68

SN6 11 60 24 137 72 0,15 1500 0,7 2,1 0,45 68SN6 16 60 24 111 58 0,15 1500 0,7 2,1 0,45 68SN6 23 60 24 145 76 0,37 1500 1,1 5 0,64 76SN6 30 60 24 188 99 0,50 3000 1,6 5 0,54 83SN6 46 60 24 141 74 0,50 3000 1,6 5 0,54 83SN6 61 60 24 130 68 0,50 1500 1,5 5 0,63 76SN6 92 60 24 111 59 0,50 3000 1,6 5 0,54 83

SN14 11 140 56 239 126 0,37 1500 1,1 5 0,64 76SN14 16 140 56 303 159 0,50 1500 1,5 5 0,63 76SN14 23 140 56 227 119 0,50 1500 1,5 5 0,63 76SN14 30 140 56 269 141 0,75 3000 1,6 5 0,81 84SN14 46 140 56 349 184 1,50 3000 3,4 24 0,77 83SN14 61 140 56 230 121 0,90 1500 2,5 11 0,67 78SN14 92 140 56 276 145 1,50 3000 3,4 24 0,77 83SN14 120 140 56 214 112 1,50 3000 3,4 24 0,77 83

SN30 16 300 120 561 295 0,90 1500 2,5 11 0,67 78SN30 23 300 120 598 314 1,50 1500 3,7 21 0,71 82SN30 30 300 120 488 256 1,50 3000 3,4 24 0,77 83SN30 46 300 120 672 353 2,20 3000 4,4 33 0,86 84SN30 61 300 120 536 282 2,20 1500 5,1 27 0,76 82SN30 92 300 120 527 277 2,20 3000 4,4 33 0,86 84SN30 120 300 120 595 313 3,00 3000 6,4 49 0,81 84

SN70 16 700 280 1386 728 2,20 1500 5,1 27 0,76 82SN70 23 700 280 1080 568 2,20 1500 7,2 37 0,54 82SN70 30 700 280 1463 769 3,00 3000 6,4 49 0,81 84SN70 46 700 280 1140 599 3,00 3000 6,4 49 0,81 84SN70 61 700 280 1223 643 4,50 1500 9,1 52 0,88 81SN70 92 700 280 1148 603 4,50 3000 9,2 69 0,82 86SN70 120 600 280 915 481 4,50 3000 9,2 69 0,82 86

SN175 16 1750 700 4084 2146 5,50 1500 11 85 0,84 86SN175 23 1750 700 3578 1880 5,50 1500 11 85 0,84 86SN175 30 1750 700 3039 1597 5,50 1500 11 85 0,84 86SN175 46 1750 700 2929 1539 7,50 1500 15 120 0,82 88SN175 61 1600 700 2441 1283 7,50 1500 15 120 0,82 88SN175 92 1100 700 1696 891 7,50 1500 15 120 0,82 88SN175 120 900 700 1512 795 9,00 1500 17 128 0,86 89

SN220 16 2200 880 4084 2146 5,5 1500 11 85 0,84 86SN220 23 2200 880 3578 1880 5,5 1500 11 85 0,84 86SN220 30 2200 880 4015 2110 7,5 1500 15 120 0,82 88SN220 46 2200 880 3371 1771 9 1500 17 128 0,86 89SN220 61 2200 880 4832 2539 15 1500 28 218 0,87 89SN220 92 2200 880 3357 1764 15 1500 28 218 0,87 89SN220 120 1700 880 2602 1367 15 1500 28 218 0,87 89

Page 13: NUCLEAR QUALIFIED ACTUATORSimg65.chem17.com/2/20151123/635839108356808023160.pdfQUAL/1997/8657b). L.Bernard maintains also the nuclear quality in accordance with ISO 9000, 50C/ SG–Q–IAEA

13

460V 60Hz

Actuator Speed Guaranteed Minimum Stall (1) Stall torque Motortorque at torque torque at at 0,85Un P Speed Current Current cos0,85Un limiter 1,05Un 156°C nominal Motor nominal starting ϕϕ Efficiency

settingType turns/min Nm Nm Nm Nm kW turns/min A A %

SN6L 13 60 15 134 71 0,07 1800 0,2 0,9 0,63 69SN6L 19 30 5 74 39 0,07 1800 0,2 0,9 0,63 69SN6LS 19 60 5 149 78 0,12 1800 0,4 1,6 0,53 68SN6L 36 20 5 51 27 0,07 1800 0,2 0,9 0,63 69SN6LS 36 60 5 101 53 0,12 1800 0,4 1,6 0,53 68SN6L 73 25 5 46 24 0,12 1800 0,4 1,6 0,53 68

SN6 13 60 24 137 72 0,18 1800 0,7 2,1 0,55 68SN6 19 60 24 111 58 0,18 1800 0,7 2,1 0,55 68SN6 28 60 24 145 76 0,44 1800 1,1 5 0,77 76SN6 36 60 24 188 99 0,60 3600 1,6 5 0,65 83SN6 55 60 24 141 74 0,60 3600 1,6 5 0,65 83SN6 73 60 24 130 68 0,60 1800 1,5 5 0,76 76SN6 110 60 24 111 59 0,60 3600 1,6 5 0,65 83

SN14 13 140 56 239 126 0,44 1800 1,1 5 0,77 76SN14 19 140 56 303 159 0,60 1800 1,5 5 0,76 76SN14 28 140 56 227 119 0,60 1800 1,5 5 0,76 76SN14 36 140 56 269 141 0,90 3600 1,6 5 0,97 84SN14 55 140 56 349 184 1,80 3600 3,4 24 0,92 83SN14 73 140 56 230 121 1,08 1800 2,5 11 0,80 78SN14 110 140 56 276 145 1,80 3600 3,4 24 0,92 83SN14 144 140 56 214 112 1,80 3600 3,4 24 0,92 83

SN30 19 300 120 561 295 1,08 1800 2,5 11 0,80 78SN30 28 300 120 598 314 1,80 1800 3,7 21 0,86 82SN30 36 300 120 488 256 1,80 3600 3,4 24 0,92 83SN30 55 300 120 672 353 2,64 3600 4,4 33 1,03 84SN30 73 300 120 536 282 2,64 1800 5,1 27 0,91 82SN30 110 300 120 527 277 2,64 3600 4,4 33 1,03 84SN30 144 300 120 595 313 3,60 3600 6,4 49 0,97 84

SN70 19 700 280 1386 728 2,64 1800 5,1 27 0,91 82SN70 28 700 280 1080 568 2,64 1800 7,2 37 0,65 82SN70 36 700 280 1463 769 3,60 3600 6,4 49 0,97 84SN70 55 700 280 1140 599 3,60 3600 6,4 49 0,97 84SN70 73 700 280 1223 643 5,40 1800 9,1 52 1,06 81SN70 110 700 280 1148 603 5,40 3600 9,2 69 0,99 86SN70 144 600 280 915 481 5,40 3600 9,2 69 0,99 86

SN175 19 1750 700 4084 1612 6,60 1800 9,1 52 1,29 81SN175 28 1750 700 3578 1412 6,60 1800 9,1 52 1,29 81SN175 36 1750 700 3039 1597 6,60 1800 11 85 1,01 86SN175 55 1750 700 2929 1539 9,00 1800 15 120 0,98 88SN175 73 1600 700 2441 1283 9,00 1800 15 120 0,98 88SN175 110 1100 700 1696 891 9,00 1800 15 120 0,98 88SN175 144 900 700 1512 795 10,80 1800 17 128 1,03 89

SN220 19 2200 880 4084 2146 6,60 1800 11 85 1,01 86SN220 28 2200 880 3578 1880 6,60 1800 11 85 1,01 86SN220 36 2200 880 4015 2110 9,00 1800 15 120 0,98 88SN220 55 2200 880 3371 1771 10,80 1800 17 128 1,03 89SN220 73 2200 880 4832 2539 18,00 1800 28 218 1,04 89SN220 110 2200 880 3357 1764 18,00 1800 28 218 1,04 89SN220 144 1700 880 2602 1367 18,00 1800 28 218 1,04 89

Page 14: NUCLEAR QUALIFIED ACTUATORSimg65.chem17.com/2/20151123/635839108356808023160.pdfQUAL/1997/8657b). L.Bernard maintains also the nuclear quality in accordance with ISO 9000, 50C/ SG–Q–IAEA

14

Dimensions & SpecificationsSN series

SN6L SN6 SN14 SN30 SN70 SN175 SN220

Weight (kg) (1) 34 62-65 64-69 85-105 121-129 282-312 284-331Dimensions (mm)

L 440 514-524 514-524 545-613 566-62 3790-917 790-917l 430 513 513 535 590 676 676h 248 334 334 380 457 525 525

Flange ISO5210 F07/F10 F10 F10 F14 F16 F25 F30Stem acceptance 32 38 38 43 54 90 90Center of gravity (2)

(mm) L’ x l’ x h’ 75x60x100 35x75x121 45x70x120 70x100x140 110x95x150 175x80x190 200x85x185Handwheeldiameter (mm) 160 300 300 450 550 500/800 800/1000

(1): excluding connector disconnectable part and considering ISO coupling C or B3.Height = distance between coupling flange and manual override handwheel.(2): average gravity center. May vary according to the exact configuration of the actuator.

Weight: 3 kg

From SN6 to SN220

Connector disconnectable part

Page 15: NUCLEAR QUALIFIED ACTUATORSimg65.chem17.com/2/20151123/635839108356808023160.pdfQUAL/1997/8657b). L.Bernard maintains also the nuclear quality in accordance with ISO 9000, 50C/ SG–Q–IAEA

15

Type of service ON/OFF or Modulating class III

Casing • Ductile iron• Casings are watertight for LOCA conditions

Mechanical technology Self locking gearing at all speeds

Motor Totally-enclosed, squirrel cage 3-phase motor, class H insulationtechnology Motors easy to remove with internal connector

Motor • S4 motor service (intermittent service on start-up) to IEC 34-1duty • S4 - 40% for ON/OFF operation - up to 360 starts per hour.rating • S4 - 50% for Modulating class III - up to 1,200 starts per hour.

Ambient operating • Standard condition: -20 °C ... +70 °C ( -4 °F ...+158 °F)temperature • Accident condition: up to 185°C (up to 312.8 °F)

External Decontaminable paint : epoxy undercoat and grey AFNOR 1625 top coatcorrosion protection Other color on request

Vibration resistance See qualification program description.

Lubrication • MOVLL Grade 0• Lubricated for product lifetime and do not require any special maintenance

Manual override • By handwheel which does not rotate during motor operation.• Automatic switch between manual and electrical drive without clutch release lever

(except for SN6L models). Electrical control has always priority.• Manual control efficiency: see table below.

Power SN actuators can operate on:supply • 3-phase power supply,

• standard voltages: 380V-50Hz, 400V-50Hz, 460V-60Hz• Other voltage on request

Output flange SN actuator flanges comply with ISO 5210.See "Mounting flange specifications" section for further details.

Connectivity • One or two connectors with screw terminals:- 30 contacts for control (max. wiring section: 5mm2)- 4 contacts for power (max. wiring section: 35mm2)

• Other type of connection on request

Conduit entries Standard configuration: 1xM40 ; 1xM32Cable gland reducer can be used

Travel limit • Position: movement reading on output shaft.systems • Range: 1.5 to 1,080 turns.

• 2 contacts as standard (up to 8 in option) ;2.5A @ 250VAC / 2.5A @ 30/48VDC / 1A@115VDC under resistive load

Torque limiting • Torque: dynamometer measuring torque transmitted.systems • The torque limiting system is pre-calibrated at the factory at the torque value provided

by the customer• 2 contacts as standard, 2.5A @ 250V under resistive load

Visual position • Graduated indicator showing valve position at all times, even in case of loss of power supplyindicatorRemote position • 1000 Ohm potentiometer, power rating: 12.5Windication (options) • Intermediate position given by SPDT switches

Handwheel SN6L SN6 SN14 SN30 SN70 SN175 SN220

Mechanical ratio 1 1 1/2 1/2 1/21 1/34 1/34

Efficiency 1 1 0.7 0.7 0.2 0.25 0.25

Handwheel diameter (mm) 160 300 300 450 550 500/800 800/1000

Handwheel diameter is calculated to comply with EN12570.

Page 16: NUCLEAR QUALIFIED ACTUATORSimg65.chem17.com/2/20151123/635839108356808023160.pdfQUAL/1997/8657b). L.Bernard maintains also the nuclear quality in accordance with ISO 9000, 50C/ SG–Q–IAEA

16

Overview of ST series

• High starting torque asynchronous motor

• Excellent starting torque over nominal torque ratio

• On/Off operation: 40% motor duty rating with peakservice conditions up to 360 starts per hour

• Modulating class III: 50% motor duty rating with peakservice conditions up to 1,200 starts per hour

• Motor built-in thermal cut-out

Power

Handwheel without clutch release

• Patented manual override system

• Differential geardrive allows the handwheel to beoperated without releasing a clutch beforehand (exceptfor very low torque values on model ST6).

• The handwheel can therefore be operated under all condi-tions, even when the valve is blocked by the torque limiter

• Electric command is always prioritary on the handwheeloperation

• Self-locking gearing at all speeds

• Continuous gear drive from the motor down to the valve

• Class F insulation motor

• Mechanical parts unaffected by vibration

• No preventative maintenance required. Gearing is lubri-cated for lifetime

Mechanical

Sensors

• Torque and position directly and mechanically measured atthe output shaft to accurately reflect the status of the valve

• Dynamometric torque measurement principle usingcalibrated springs mechanically linked to the outputshaft. This torque limiting system ensures a very goodrepeatability, low long-term drift and extremely shortresponse time. The torque sensor fast response enables the controlsystem to cut off the motor supply rapidly, thus limitingthe overtorque applied to the valve

• Travel limit switch setting : easy and reliable patentedcamblock

• Torque limit switch setting : easy and reliable with visualindicator and without any special tools Connection

• Standard connection through cable glands

• Pluggable connector available on request

• External earth terminal

• A test connector can be mounted inside the actuator toperform tests on site

The ST series is a multi turn series designed for outside containment safety-related service or non safety relatedarea. It can be used for On-Off or Modulating Class III applications. This serie takes into account feedback onseveral years of exploitation in Oil & Gas and Nuclear markets.

ST actuator with INTEGRAL+ control

Qualified multiturn actuators foroutside containment (Nuc OC)

Page 17: NUCLEAR QUALIFIED ACTUATORSimg65.chem17.com/2/20151123/635839108356808023160.pdfQUAL/1997/8657b). L.Bernard maintains also the nuclear quality in accordance with ISO 9000, 50C/ SG–Q–IAEA

17

ST Qualification description

ST “K3” range qualification program is an envelop covering both RCC-E and IEEE qualification requirements. For example, for vibration and seism tests, we used envelop curve.

(*) with 50% of maximum load

Integrated electronic control qualificationST range is also qualified with electronic controls INTEGRAL+. For this application, the control box can be separated fromthe actuator to a maximum distance of 50 meters.

Special conditionsMoreover, by analysis, ST range is qualified for 5kGy radiation and a temperature of 100°C during 24h.

Tests were witnessed by an independent third party company: Bureau Véritas.

This product, in its “NUC OC” configuration, meets the requirements of EPR and non-EPR nuclear power stations. Ithas been qualified in accordance with:• RCC-E (2002) - Design and Construction Rules for Electrical Components of Nuclear Islands

• IEEE Std 382 (1996) - IEEE Standard for qualification of actuators for power-operated valve assemblies with safety-relatedfunctions for nuclear power plants

X

X (*)

X (*)

Qualification program ST qualification Operation during the test

Thermal aging 40 years at 40°C

Damp heat test 2 cycles of 24hfollowing standard EN 60068-2-30 (variante 2)

Fonctional test 2,000 cycles ON/OFF200,000 steps MODULATING

Vibration aging Up to 2g, 5-500-5Hz, 90min on each axis

Seismic test OBE : up to 3g, 1-40-1HzSSE line mounted : up to 4,5g, 2-32HzSSE Hard mounted : up to 20g, 1-60H

Page 18: NUCLEAR QUALIFIED ACTUATORSimg65.chem17.com/2/20151123/635839108356808023160.pdfQUAL/1997/8657b). L.Bernard maintains also the nuclear quality in accordance with ISO 9000, 50C/ SG–Q–IAEA

ST Performance data

This table shows performance data for a 3-phase 400V 50Hz power supply.

400V 50Hz

18

Actuator Speed Guaranteed Min. set Stall (1) Motortorque at torque torque at P Speed I n I d cos Motor0,85Un in 1,05Un Motor ϕϕ Efficiency

standardType turns/min Nm Nm Nm kW turns/min A A %

ST6 11 60 24 100 0,10 750 0,8 1,6 0,51 37ST6 16 50 24 81 0,10 750 0,8 1,6 0,51 37ST6 23 60 24 152 0,37 1500 1,1 5 0,7 70ST6 30 60 24 120 0,37 1500 1,1 5 0,7 70ST6 46 50 24 90 0,37 1500 1,1 5 0,7 70ST6S 46 60 24 141 0,50 1500 1,5 5 0,78 65ST6 61 60 24 133 0,50 3000 1,6 5 0,9 53ST6 92 60 24 100 0,50 3000 1,6 5 0,9 53

ST14 11 140 56 240 0,37 1500 1,1 5 0,7 70ST14 16 120 56 194 0,37 1500 1,1 5 0,7 70ST14S 16 140 56 304 0,50 1500 1,5 5 0,78 65ST14 23 140 56 228 0,50 1500 1,5 5 0,78 65ST14 30 120 56 189 0,50 3000 1,6 5 0,9 53ST14 46 140 56 350 1,50 3000 3,4 24 0,88 77ST14 61 130 56 213 0,90 1500 2,7 14 0,7 77ST14 92 140 56 276 1,50 3000 3,4 24 0,88 77ST14 120 130 56 214 1,50 3000 3,4 24 0,88 77

ST30 16 300 120 520 0,90 1500 2,7 14 0,7 77ST30 23 300 120 599 1,50 1500 3,7 21 0,82 75ST30 30 300 120 489 1,50 3000 3,4 24 0,88 77ST30 46 300 120 674 2,20 3000 4,4 33 0,89 82ST30 61 280 120 445 2,20 1500 5,1 27 0,81 76ST30S 61 300 120 671 3,00 1500 7,2 37 0,79 77ST30 92 300 120 529 2,20 3000 4,4 33 0,89 82ST30 120 260 120 418 2,20 3000 4,4 33 0,89 82ST30S 120 300 120 596 3,00 3000 6,4 49 0,81 84

ST70 16 700 280 1150 2,20 1500 5,1 27 0,81 76ST70 23 700 280 1353 3,00 1500 7,2 37 0,79 77ST70 30 700 280 1466 3,00 3000 6,4 49 0,81 84ST70 46 700 280 1143 3,00 3000 6,4 49 0,81 84ST70 61 600 280 975 4,00 1500 9,1 52 0,79 80ST70 92 700 280 1151 4,50 1500 9,2 69 0,85 80ST70 120 550 280 917 4,50 3000 9,2 69 0,85 80ST70 190 400 280 644 4,50 3000 9,2 69 0,85 80

ST175 36 1750 700 1151 4,50 1500 9,2 69 0,85 80ST175 46 1600 700 917 4,50 3000 9,2 69 0,85 80ST175 61 1600 700 644 4,50 3000 9,2 69 0,85 80

ST220 16 2200 880 4001 5,50 1500 12,5 100 0,74 86ST220 23 2200 880 3505 5,50 1500 12,5 100 0,74 86ST220 30 1900 880 2977 5,50 1500 12,5 100 0,74 86ST220 36 2000 880 3142 7,50 1500 16,5 115 0,77 85ST220 46 1900 880 3016 9,00 1500 18,1 135 0,83 87ST220 61 2200 880 4860 15,00 1500 29,2 220 0,84 88ST220 92 2200 880 3376 15,00 1500 29,2 220 0,84 88ST220 120 1700 880 2617 15,00 1500 29,2 220 0,84 88

(1) Maximal output torque in abnormal conditions with torque limit system out of service (with transient speedof the motor of about 1200 rpm).Actuators with 1500rpm (or 750rpm) speed motors are available in both on-off and Class III Modulatingexcept ST175 and ST220 which are available in On-Off only.

Page 19: NUCLEAR QUALIFIED ACTUATORSimg65.chem17.com/2/20151123/635839108356808023160.pdfQUAL/1997/8657b). L.Bernard maintains also the nuclear quality in accordance with ISO 9000, 50C/ SG–Q–IAEA

19

This table shows performance data for a 3-phase 460V 60Hz power supply.

460V 60Hz

Actuator Speed Guaranteed Min. set Stall (1) Motor torque at torque torque at P Speed I n I d cos Motor0,85Un in 1,05Un Motor ϕϕ Efficiency

standardType turns/min Nm Nm Nm kW turns/min A A %

ST6 13 60 24 100 0,12 900 0,8 1,6 0,51 37ST6 19 50 24 81 0,12 900 0,8 1,6 0,51 37ST6 28 60 24 152 0,44 1800 1,1 5 0,7 70ST6 36 60 24 120 0,44 1800 1,1 5 0,7 70ST6 55 50 24 90 0,44 1800 1,1 5 0,7 70ST6S 55 60 24 141 0,60 1800 1,5 5 0,78 65ST6 73 60 24 133 0,60 3600 1,6 5 0,9 53ST6 110 60 24 100 0,60 3600 1,6 5 0,9 53

ST14 13 140 56 240 0,44 1800 1,1 5 0,7 70ST14 19 120 56 194 0,44 1800 1,1 5 0,7 70ST14S 19 140 56 304 0,60 1800 1,5 5 0,78 65ST14 28 140 56 228 0,60 1800 1,5 5 0,78 65ST14 36 120 56 189 0,60 3600 1,6 5 0,9 53ST14 55 140 56 350 1,80 3600 3,4 24 0,88 77ST14 73 130 56 213 1,08 1800 2,7 14 0,7 77ST14 110 140 56 276 1,80 3600 3,4 24 0,88 77ST14 144 130 56 214 1,80 3600 3,4 24 0,88 77

ST30 19 300 120 520 1,08 1800 2,7 14 0,7 77ST30 28 300 120 599 1,80 1800 3,7 21 0,82 75ST30 36 300 120 489 1,80 3600 3,4 24 0,88 77ST30 55 300 120 674 2,64 3600 4,4 33 0,89 82ST30 73 280 120 445 2,64 1800 5,1 27 0,81 76ST30S 73 300 120 671 3,60 1800 7,2 37 0,79 77ST30 110 300 120 529 2,64 3600 4,4 33 0,89 82ST30 144 260 120 418 2,64 3600 4,4 33 0,89 82ST30S 144 300 120 596 3,60 3600 6,4 49 0,81 84

ST70 19 700 280 1150 2,64 1800 5,1 27 0,81 76ST70 28 700 280 1353 3,60 1800 7,2 37 0,79 77ST70 36 700 280 1466 3,60 3600 6,4 49 0,81 84ST70 55 700 280 1143 3,60 3600 6,4 49 0,81 84ST70 73 600 280 975 4,80 1800 9,1 52 0,79 80ST70 110 700 280 1151 5,40 3600 9,2 69 0,85 80ST70 144 550 280 917 5,40 3600 9,2 69 0,85 80ST70 226 400 280 644 5,40 3600 9,2 69 0,85 80

ST175 43 1750 700 2715 6,60 1800 12,5 100 0,74 86ST175 55 1600 700 2514 9,00 1800 16,5 115 0,77 85ST175 73 1600 700 2514 10,80 1800 18,1 135 0,83 87

ST220 19 2200 880 4001 6,60 1800 12,5 100 0,74 86ST220 28 2200 880 3505 6,60 1800 12,5 100 0,74 86ST220 36 1900 880 2977 6,60 1800 12,5 100 0,74 86ST220 43 2000 880 3142 9,00 1800 16,5 115 0,77 85ST220 55 1900 880 3016 10,80 1800 18,1 135 0,83 87ST220 73 2200 880 4860 18,00 1800 29,2 220 0,84 88ST220 110 2200 880 3376 18,00 1800 29,2 220 0,84 88ST220 144 1700 880 2617 18,00 1800 29,2 220 0,84 88

(1) Maximal output torque in abnormal conditions with torque limit system out of service (with transient speedof the motor of about 1200 rpm).Actuators with 1800rpm (or 900rpm) speed motors are available in both on-off and Class III Modulatingexcept ST175 and ST220 which are available in On-Off only.

Page 20: NUCLEAR QUALIFIED ACTUATORSimg65.chem17.com/2/20151123/635839108356808023160.pdfQUAL/1997/8657b). L.Bernard maintains also the nuclear quality in accordance with ISO 9000, 50C/ SG–Q–IAEA

20

Connection can be done with different system:

- screw terminals (integrated in the main housing)

- clips terminals (integrated in an additional box)

- connector (same type as SN range)

Overall dimensions - NC and Nuc O.C standard version

ST6 ST14 ST30 ST70 ST175 ST220

Weight 25 31 48 63 266 266Dimensions (mm)

L 472 469-479 509-579 547-617 791-918 791-918 l 409 403 535 603 882 882 H-B3/C form 283 316 363 443 525 525 H-A form 341 375 441 547 661 661 H-B1 form 341 375 450 547 661 661

Center of gravity (mm) L’ x l’ x h’ 76x74x90 79x16x118 75x58x154 95x53x171 127x56x199 127x56x199Handwheeldiameter (mm) 160-300 300 450 550 500-800 800-1000

Dimensions & SpecificationsST series without controls

Page 21: NUCLEAR QUALIFIED ACTUATORSimg65.chem17.com/2/20151123/635839108356808023160.pdfQUAL/1997/8657b). L.Bernard maintains also the nuclear quality in accordance with ISO 9000, 50C/ SG–Q–IAEA

21

Type of service ON/OFF or Modulating class IIICasing • Cast aluminium.

• Casings are watertight to IP68 & NEMA 6 and can withstand pressure of 10 metresWC for 96 hours.

Motor Totally-enclosed, squirrel cage 3-phase or 1-phase motor, class F insulation withtechnology integral thermal overload protection. Motors easy to remove with sealed ball

bearings fitted at front and rear.Motor • S4 motor service (intermittent service on start-up) to IEC 34-1.duty • S4 - 30% for ON/OFF operation - up to 360 starts per hour.rating • S4 - 50% for Modulating class III - up to 1,200 starts per hour.

Ambient • Standard version: -20 °C ... +70 °C ( -4 °F ...+158 °F)operating • Low temperature version: -40 °C ... +70 °C ( -40 °F ... +158 °F)temperature • High temperature version : +0 °C ... +100 °C (+32 °F ... +194 °F)

External corrosion Standard paint system: Zinc rich primer, epoxy undercoat and RAL5002 blueprotection polyurethane top coat.

Special protection for radiation ; environment available on request

Vibration resistance See qualification description.

Lubrication ST actuators are lubricated for the product lifetime and do not require anyspecial service.

Manual control • By handwheel which does not rotate when electrical operation system in service.• Switch between manual and electrical operation automatically without clutch

release lever (except for ST6 models). Electrical control has always priority.Power ST actuators can operate on a wide variety of power supplies:supply • single-phase or 3-phase, DC,

• up to 690 V (depending on version),• 50 or 60 Hz, etc.

Output flange ST actuator flanges comply with ISO 5210.See "Mounting flange specifications" section for further details.

Conduit entries Standard configuration: 2 x M20. External Earth Connection: Mono wire. Max.section 6 mm2.Other cable entry configuration options available on request.

Travel • Position: movement reading on output shaft.limit systems • Range: 1.5 to 1,080 turns.

• 2 contacts as standard (up to 8 as option) ; 16A to 250V under resistive loadTorque • Torque: dynamometer measuring torque transmitted.limiting systems • The torque limiting system is calibrated at the factory to the torque setting

selected by the customer.• 2 contacts as standard; 16A to 250V under resistive load

Visual • Graduated indicator showing position at all times, even if no power supplyposition indicator present.

Remote position • 1000 Ohm potentiometer, 0.3W - wiper current = max. 1 mA. (Non Safety indication (option) Related Area application)

• 1000 Ohm potentiometer, 2W - wiper current = max. 1 mA. (Outside Containmentapplication)

• TAM position transmitter: 4-20mA (12, 24 or 32V power supply for maximumpermissible load of 150, 750 or 1,050 Ohms). (Non Safety Related Area application)

• Intermediate positions given by SPDT switches.• Others on request.

Compliance Weatherproof version ST actuators comply with:with EC Directives • directive 89/336/EEC, as amended by 93/68/EEC: Electromagnetic compatibility

• directive 73/23/EEC, as amended by 93/68/EEC: Low voltage• the following harmonised standards: EN 61000-6-4: Generic emissions standard

for industrial environments; EN 61000-6-2: Generic immunity standard for industrialenvironments; EN 60034-1: Rotating electrical machines; EN 60529: Degrees of protection provided by enclosures (IP ratings code)

Handwheel ST6 ST14 ST30 ST70 ST175 ST220

Mechanical ratio 1 1/2 1/2 1/21 1/34 1/34

Efficiency 1 0.7 0.7 0.2 0.25 0.25

Handwheel diameter (mm) 300 300 450 550 500/800 800/100

Handwheel diameter is calculated to comply with EN12570.

These specifications are for standard versions (no integrated controls) either safety related ot not).

Page 22: NUCLEAR QUALIFIED ACTUATORSimg65.chem17.com/2/20151123/635839108356808023160.pdfQUAL/1997/8657b). L.Bernard maintains also the nuclear quality in accordance with ISO 9000, 50C/ SG–Q–IAEA

22

Overall dimensions - ST with INTEGRAL+ control box

H

L l

INTEGRAL+ controls for use in nuclear outside containment environment is available in a separated box configura-tion only.

ST6 ST14 ST30 ST70

Weight 32 40 61 85Dimensions (mm)

L (max) 630 626 736 739l 472 450 570 638H-B3/C form 283 317 364 447H-A form 341 375 441 547H-B1 form 341 375 450 547

Handwheeldiameter (mm) 300 300 450 550

Dimensions & SpecificationsST Series with control box

Page 23: NUCLEAR QUALIFIED ACTUATORSimg65.chem17.com/2/20151123/635839108356808023160.pdfQUAL/1997/8657b). L.Bernard maintains also the nuclear quality in accordance with ISO 9000, 50C/ SG–Q–IAEA

23

These specifications are for weatherproof versions with integrated controls INTEGRAL+ or POSIGAM+

Refer to INTEGRAL+ (ref. A115) catalogue for further information on control functions.

Models Versions according to operating modes:• INTEGRAL+ for ON/OFF• POSIGAM+ for Class III modulating

INTEGRAL+ includes: POSIGAM+ includes:• Terminal compartment • All INTEGRAL+ features• Power contactors • Positioner board• Logic control • Precision feedback • Configuration panel potentiometer, linearity<0.5%• Signalling relays• Local control selectors

Enclosure protection Weather proof design IP67 / NEMA 4

Temperature Ambiant temperature range: -40°C ...+70°C ( -40°F ... +158°F)

External corrosion Paint system and colour are the same as the actuator on which INTEGRAL+ is mountedprotection

On-off control • Isolated by opto-couplers• Voltage: 10 to 250 V DC/AC• Current: 10 mA at 24V• Dry contacts (uses INTEGRAL+ auxillary DC supply)• Minimum pulse duration: 100ms• Time of rotational direction change: 50ms or 200ms

Modulating control • Standard input signal: 4-20 mA - output signal: 4-20mA• Input signal: 0-20 mA - output signal: 0-20 mA• Input signal: 0-10 V - output signal: 0-20 mA

Signalling relays • 4 relays: four information can be freely selected among a total of 16 available information (250 VAC-5A max.)• Contact configuration: normally open or normally closed

Default relay • SPDT contact• Contact configuration: normally open or normally closed

Power supply Same power supply as the actuator

Electrical connection Screw type terminals

Cable entries Standard configurations (other on request): 3xM20 (2 for signalling, 1 for power supply)

Vibration / Seism See ST qualification program description

EU conformity INTEGRAL+ controls comply with:• The 89/336/EEC directive modified by 93/68/EEC electromagnetic compatibility• The 73/23/EEC directive modified by 93/68/EEC Low Voltage• The following harmonized standards: Generic emission standard-Industrial environment EN 50081-2 Generic immunity standard - Industrial environment EN 50082-2 ; Rotating electrical machines EN 60034-1, Degrees of protection provided by enclosures (IP code) EN 6052

Options • Additional 3 relays board• Separated box

Page 24: NUCLEAR QUALIFIED ACTUATORSimg65.chem17.com/2/20151123/635839108356808023160.pdfQUAL/1997/8657b). L.Bernard maintains also the nuclear quality in accordance with ISO 9000, 50C/ SG–Q–IAEA

Overview of SD series

• Asynchronous motor with high starting torque

• Excellent starting torque / nominal torque ratio

• On/Off operation: 40% duty rating for peak serviceconditions of up to 360 starts per hour

• Modulating class III: 50% duty rating for peak service conditions of up to 1,200 starts per hour

Power

Torque sensorsMechanical

Position sensors

• Direct position measurement is on the output shaft for OAactuators

• Direct position measurement is on helical reduction gear onmain worm for AS/BS actuators

• Travel limit switch setting : easy and reliable with L.Bernard camblock patented system

• Each single cam can be set independently from theothers

• Cams are locked in position so setting is unaffected byvibrations

The SD series are quarter turn actuators designed for outside containment safety related service or for nonsafety-related area. They can be used for On-Off or Modulating Class III applications. They have been designedto operate quarter turn valves directly (without any additional gearbox).

24

• Gear design with two reduction stages. The first one isa planetary system with high speed reduction and excel-lent efficiency. The second one is an largely sized wormand quadrant gear type.

• Gearing is self-locking at all speeds

• Continuous gear drive from the motor down to the valve

• Class F insulation motor

• Unaffected by vibrations

• No preventative maintenance required. Gearing is lubri-cated for lifetime

Standard specifications

• Thermal cut out motor to protect from overheating

• Handwheel is plain and rotating during electric opera-tion, other configurations are available on request

• Connection by cable glands and terminal blocks, othertypes on request

• Optical position indicator always available

SD series INTEGRAL+ optional control box

• The ouput torque for valve operation is permanentlymeasured by the lever deflection of the planetary gearexternal crown (AS/BS). This crown Gear is permanentlymaintained in position by two calibrated Linear springs

• Torque setting is independent for each direction

• Torque measure is mechanically friction free so measure isvery precise and reliable

• Due to the low torque, no torque sensor available onOA actuators.

Qualified quarter-turn actuators foroutside containment (Nuc OC)

Page 25: NUCLEAR QUALIFIED ACTUATORSimg65.chem17.com/2/20151123/635839108356808023160.pdfQUAL/1997/8657b). L.Bernard maintains also the nuclear quality in accordance with ISO 9000, 50C/ SG–Q–IAEA

SD Qualification description

25

AS and BS series qualification program is an envelop of RCC-E and IEEE qualification program. For example, for vibration and seism tests, we used envelop curve.

(*) with 50% of maximum load

Integrated electronic control qualificationAS and BS series are also qualified with electronic control INTEGRAL+. For this application, electronic box must be sepa-rated. Maximum distance allowed is 50m.

Special conditionsMoreover, SD series are qualified for 5kGy radiation and a temperature of 100°C during 24h.

Tests were witnessed by an independent third party company: Bureau Véritas.

These products meet the requirements of EPR and non-EPR nuclear power stations. They are qualified in accordancewith:• RCC-E (2002) - Design and Construction Rules for Electrical Components of Nuclear Islands

• IEEE Std 382 (1996) - IEEE Standard for qualification of actuators for power-operated valve assemblies with safety-relatedfunctions for nuclear power plants

X

X (*)

X (*)

Qualification program SD qualification Operation during the test

Thermal aging 30 years at 40°C

Damp heat test 2 cycles of 24hfollowing standard EN 60068-2-30 (variante 2)

Fonctional test 2000 cycles ON/OFF200000 steps MODULATING

Vibration aging Up to 2g, 5-500-5Hz, 90min on each axis

Seismic test OBE : up to 3g, 1-40-1HzSSE line mounted : up to 4,5g, 2-32HzSSE Hard mounted : up to 20g, 1-60H

Page 26: NUCLEAR QUALIFIED ACTUATORSimg65.chem17.com/2/20151123/635839108356808023160.pdfQUAL/1997/8657b). L.Bernard maintains also the nuclear quality in accordance with ISO 9000, 50C/ SG–Q–IAEA

SD Performance data

3 x 400V 50Hz

26

Actuator Operating Guaranteed Permanent Stall (1) Motor time torque at torque torque at P Speed Curent Curent cos Motor

0,85Un 1,05Un ϕϕ Efficiency

Type 90°/sec Nm Nm Nm kW rpm rated A start A %

AS18 5 200 140 350 0,10 1500 0,6 1,1 0,6 40AS25 5 250 140 462 0,15 1500 0,7 2,1 0,6 58AS25 10 300 140 633 0,10 750 0,8 1,6 0,5 37ASP25 30 250 140 530 0,03 1500 0,3 0,5 0,5 30ASP25 50 250 140 857 0,03 1500 0,3 0,5 0,5 30AS50 30 600 400 1016 0,06 1500 0,3 0,8 0,8 35AS50 60 600 400 1288 0,06 750 0,6 0,9 0,4 40AS80 30 650 400 1016 0,06 1500 0,3 0,8 0,8 35AS80 60 800 400 1288 0,06 750 0,6 0,9 0,4 40

BS100 30 1000 750 2470 0,10 1500 0,6 1,1 0,6 40BS100 30 1200 750 2495 0,06 1500 0,3 0,8 0,8 35

1 x 230V 50Hz

Actuator Operating Guaranteed Permanent Stall (1) Motor time torque at torque torque at P Speed Curent Curent cos Motor

0,85Un 1,05Un ϕϕ Efficiency

Type 90°/sec Nm Nm Nm kW rpm rated A start A %

OA3 6 45 35 69 0,03 1500 0,8 0,9 0,9 15OAP 35 100 60 221 0,02 1500 0,5 0,6 0,9 12OAP 60 100 60 258 0,03 1500 0,6 0,9 0,9 22

Page 27: NUCLEAR QUALIFIED ACTUATORSimg65.chem17.com/2/20151123/635839108356808023160.pdfQUAL/1997/8657b). L.Bernard maintains also the nuclear quality in accordance with ISO 9000, 50C/ SG–Q–IAEA

27

3 x 460V 60Hz

Actuator Operating Guaranteed Permanent Stall (1) Motor time torque at torque torque at P Speed Curent Curent cos Motor

0,85Un 1,05Un ϕϕ Efficiency

Type 90°/sec Nm Nm Nm kW rpm rated A start A %

AS18 4 200 140 350 0,12 1800 0,6 1,1 0,6 40AS25 4 250 140 462 0,18 1800 0,7 2,1 0,6 58AS25 8 300 140 633 0,12 900 0,8 1,6 0,5 37ASP25 25 250 140 530 0,04 1800 0,3 0,5 0,5 30ASP25 40 250 140 857 0,04 1800 0,3 0,5 0,5 30AS50 25 600 400 1016 0,07 1800 0,3 0,8 0,8 35AS50 50 600 400 1288 0,07 900 0,6 0,9 0,4 40AS80 25 650 400 1016 0,07 1800 0,3 0,8 0,8 35AS80 50 800 400 1288 0,07 900 0,6 0,9 0,4 40

BS100 30 1000 750 2470 0,12 1800 0,6 1,1 0,6 40BS100 60 1200 750 2495 0,07 1800 0,3 0,8 0,8 35

1 x 1 15V 60Hz

Actuator Operating Guaranteed Permanent Stall (1) Motortime torque at torque torque at P Speed Curent Curent cos Motor

0,85Un 1,05Un ϕϕ Efficiency

Type 90°/sec Nm Nm Nm kW rpm rated A start A %

OA3 5 45 35 69 0,032 1800 1,5 1,8 0,9 21OAP 30 100 60 184 0,015 1800 1,1 1,6 0,9 13OAP 50 100 60 533 0,03 1800 1,3 2 0,9 23

Page 28: NUCLEAR QUALIFIED ACTUATORSimg65.chem17.com/2/20151123/635839108356808023160.pdfQUAL/1997/8657b). L.Bernard maintains also the nuclear quality in accordance with ISO 9000, 50C/ SG–Q–IAEA

OA type overall dimensions

OA3 OAP

Weight 8 09-10Dimensions (mm)

L 273 315-362l 200 200H 225 225

Center of gravity (mm) 37x28x82 53x27x82L’ x l’ x H’Handwheel diameter (mm) 90 90

28

AS18 AS25 ASP AS50 AS80 BS100

Weight 19-24 23 17-18 20 23-30 28-35Dimensions (mm)

L 415-479 479 413-459 465-528 465-528 520-583l 313 313 313 313 313 424H 180 180 180 225 256 167

Center of gravity (mm) 41x47x91 79x49x91 39x46x89 60x49x80 60x43x113 81x72x80L’ x l’ x H’Handwheel diameter (mm) 160 160 160 250 250 250

AS / BS types overall dimensions

Dimensions & SpecificationsSD series without controls

Page 29: NUCLEAR QUALIFIED ACTUATORSimg65.chem17.com/2/20151123/635839108356808023160.pdfQUAL/1997/8657b). L.Bernard maintains also the nuclear quality in accordance with ISO 9000, 50C/ SG–Q–IAEA

Type of service ON/OFF or Modulating class III

Casing • Cast aluminium• Casings are watertight to IP67 & NEMA 6

IP68 on requestMotor Totally-enclosed, squirrel cage 3-phase or 1-phase motor, class F insulation withtechnology built-in thermal overload protection. Motors easy to remove with sealed ball

bearings fitted at front and rear.Motor • S4 motor service (intermittent service on start-up) to IEC 34-1.duty • S4 - 40% for ON/OFF operation - up to 360 starts per hour.rating • S4 - 50% for Modulating class III - up to 1,200 starts per hour.

Ambient • Standard version: -20 °C ... +70 °C ( -4 °F ...+158 °F)operating • Low temperature version: -40 °C ... +70 °C ( -40 °F ... +158 °F)temperature • High temperature version : +0 °C ... +100 °C (+32 °F ... +212 °F)

External corrosion Standard paint system: Zinc rich primer, epoxy undercoat and RAL5002 blueprotection polyurethane top coat.

Special protection for radiation ; environment available on request

Vibration See SD qualification description.resistanceLubrication SD actuators are lubricated for product lifetime and do not require any

specific maintenance.

Manual control • By plain handwheel which rotates during motor operation.• Automatic switch between manual and motor operation without clutch release

lever. Electrical control has always priority.

Power SD actuators can operate on a wide variety of power supplies:supply • single-phase or 3-phase, DC,

• up to 690 V (depending on version),• 50 or 60 Hz, etc.

Output flange SD actuator flanges comply with ISO 5211.See "Mounting flange specifications" section for further details.

Conduit entries Standard configuration: 2 x M20Other cable entry configuration options available on request.

Travel • Position: movement reading on output shaft (OA), on helical reduction gear limit systems on main worm for AS/BS

• 2 contacts as standard (up to 8 as option) ; 16A to 250V under resistive loadTorque • Torque limiting device available on AS and BS actuators. Not available on OA.limiting systems • Torque measured on the external crown of the planetary gear

• The torque limiting system is calibrated at the factory to the maximum torqueof the actuator unless otherwise specified

• 2 contacts as standard; 16A to 250V under resistive load

Visual • Graduated indicator showing position at all times, even in case of loss of position indicator power supply

Remote position • 1000 Ohm potentiometer qualified for outside containment, 2W - wiperindication (options) current = max. 1 mA.

• 1000 Ohm potentiometer not qualified, 0.3W - wiper current = max. 1 mA• TAM position transmitter: 4-20mA (12, 24 or 32V power supply for maximum

permissible load of 150, 750 or 1,050 Ohms). Not qualified for outside containement• Intermediate positions given by SPDT switches.• Others on request.

Compliance Weatherproof version SD actuators comply with:with EC Directives • directive 89/336/EEC, as amended by 93/68/EEC: Electromagnetic compatibility

• directive 73/23/EEC, as amended by 93/68/EEC: Low voltage• the following harmonised standards: EN 61000-6-4: Generic emissions standard

for industrial environments; EN 61000-6-2: Generic immunity standard for industrialenvironments; EN 60034-1: Rotating electrical machines; EN 60529: Degrees of protection provided by enclosures (IP ratings code)

29

These specifications are for standard versions for safety related service or not

Page 30: NUCLEAR QUALIFIED ACTUATORSimg65.chem17.com/2/20151123/635839108356808023160.pdfQUAL/1997/8657b). L.Bernard maintains also the nuclear quality in accordance with ISO 9000, 50C/ SG–Q–IAEA

30

Separate control box dimensions

Dimensions & SpecificationsSD series separated control box

Integral or Posigam controls for Nuc OC qualified SD series is available solely in separate box configuration.

Ll

H

Weight 6 kg Dimensions (mm)

L 276l 156

H (without cable galnds) 193

Page 31: NUCLEAR QUALIFIED ACTUATORSimg65.chem17.com/2/20151123/635839108356808023160.pdfQUAL/1997/8657b). L.Bernard maintains also the nuclear quality in accordance with ISO 9000, 50C/ SG–Q–IAEA

31

These data are for Integral or Posigam control box only

Models Versions according to operating modes:• INTEGRAL+ for ON/OFF• POSIGAM+ for Class III modulating

INTEGRAL+ includes: POSIGAM+ includes:• Terminal compartment • All INTEGRAL+ features• Power contactors • Positioner board• Logic control • Precision feedback • Configuration panel potentiometer, linearity<0.5%• Signalling relays• Local control selectors

Enclosure protection Weather proof design IP67 / NEMA 4

Temperature Ambiant temperature range: -40°C ...+70°C ( -40°F ... +158°F)

External corrosion Paint system and colour are the same as the actuator on which INTEGRAL+ is mountedprotection

On-off control • Isolated by opto-couplers• Voltage: 10 to 250 V DC/AC• Current: 10 mA at 24V• Dry contacts (uses INTEGRAL+ auxillary DC supply)• Minimum pulse duration: 100ms• Time of rotational direction change: 50ms or 200ms

Modulating control • Standard input signal: 4-20 mA - output signal: 4-20mA• Input signal: 0-20 mA - output signal: 0-20 mA• Input signal: 0-10 V - output signal: 0-20 mA

Signalling relays • 4 relays: four information can be freely selected among a total of 16 available information (250 VAC-5A max.)• Contact configuration: normally open or normally closed

Default relay • SPDT contact• Contact configuration: normally open or normally closed

Power supply Same power supply as the actuator

Electrical connection Screw type terminals

Cable entries Standard configurations (other on request): 3xM20 (2 for signalling, 1 for power supply)

Vibration / Seism See SD qualification program description

EU conformity INTEGRAL+ controls comply with:• The 89/336/EEC directive modified by 93/68/EEC electromagnetic compatibility• The 73/23/EEC directive modified by 93/68/EEC Low Voltage• The following harmonized standards: Generic emission standard-Industrial environment EN 50081-2 Generic immunity standard - Industrial environment EN 50082-2 ; Rotating electrical machines EN 60034-1, Degrees of protection provided by enclosures (IP code) EN 6052

Options • Additional 3 relays board

Page 32: NUCLEAR QUALIFIED ACTUATORSimg65.chem17.com/2/20151123/635839108356808023160.pdfQUAL/1997/8657b). L.Bernard maintains also the nuclear quality in accordance with ISO 9000, 50C/ SG–Q–IAEA

ISO 5210 guidelines

Flange

F10

F14

F16

F25

F30

Maxtorque

100 N.m

400 N.m

700 N.m

1200 N.m

2500 N.m

Max. thrust withstem nut

40 000 N

100 000 N

150 000 N

200 000 N

325 000 N

Mounting bolts

4 x M10 / d=102 mm

4 x M16 / d=140 mm

4 x M20 / d=165 mm

8 x M16 / d=254 mm

8 x M20 / d=298mm

OptionType A

STEM NUT

StandardType C

CLAW COUPLING

OptionType B3/B4

SMALL DIA.

OptionType B1/B2

LARGE DIA.

Thrust accepted Thrust not accepted Thrust not accepted Thrust not accepted

Valve side

Actuatorside

ISO5210 types of drive forms

ISO 5210 max. torque / max. thrust / bolting guidelines

32

Page 33: NUCLEAR QUALIFIED ACTUATORSimg65.chem17.com/2/20151123/635839108356808023160.pdfQUAL/1997/8657b). L.Bernard maintains also the nuclear quality in accordance with ISO 9000, 50C/ SG–Q–IAEA

33

Other actuation solutionsfor nuclear power plants

High Duty Modulating- 100% duty service- Different models suitable for use as:

. Class II modulating: moderate speed, high precision

. Class I modulating: high speed, very high precision- Quarter-turn, linear, multiturn and lever movements- Specific turnkey electronic control solutions available

Failsafe- Failsafe with reliable spring-return technology- Fast and shock-free valve travel during emergency

operation- Maintenance-free- Explosionproof versions (ATEX-NEMA)- Nuc IC and Nuc OC versions

Conventional actuators- A complete range of non-qualified actuators for :

. Steam valves

. Cooling towers

. Dampers & fans, etc ...- For On-Off up to Class I positioning duty- Available with INTELLI+ non-intrusive controls

Page 34: NUCLEAR QUALIFIED ACTUATORSimg65.chem17.com/2/20151123/635839108356808023160.pdfQUAL/1997/8657b). L.Bernard maintains also the nuclear quality in accordance with ISO 9000, 50C/ SG–Q–IAEA

4 rue d’Arsonval - BP 70091 - 95505 Gonesse - FranceTel: +33.1. 34.07.71.00 - Fax: +33.1.34.07.71.01E-mail: [email protected]: http://www.bernard-actuators.com

A12

0-00

P

HO

TO C

RED

ITS:

L B

ern

ard

. Ph

oto

s ta

ken

fro

m r

oya

lty-

free

CD

s. L

Ber

nar

d r

eser

ves

the

rig

ht

to c

han

ge

the

spec

ific

atio

ns

con

tain

ed in

th

is d

ocu

men

t w

ith

ou

t n

oti

ce.

At your service around the world

AUSTRALIA TRANSMARK - [email protected] ROWVILLE, VICTORIA

Tel.: + 61 3 97 65 61 11Fax: + 61 3 97 65 61 65

AUSTRIA IPU ING PAUL UNGER WIEN [email protected] Tel.: +43 1 602 41 49

Fax: +43 1 603 29 43

BELGIUM BERNARD BENELUX SAchristian.baert@ bernard-benelux.com BRUXELLES

Tel.: +32 (0)2 343 41 22Fax: +32 (0)2 347 28 43

BRAZIL JCN SAO [email protected] Tel.: +55 11 39 02 26 00

Fax: +55 11 39 02 40 18

CHINA BEIJING BERNARD CONTROLEQUIPMENT

[email protected] Tel.: +86 10 8739 77 27Fax: +86 10 8739 77 04

CZECH REPUBLIC FLUIDTECHNIK BOHEMIA [email protected] BRNO

Tel.: +420 548 213 233-5Fax: +420 548 213 238

DENMARK ARMATEC A/S [email protected] Tel.: +45 46 96 00 00www.armatec.dk Fax: +45 46 96 00 01

EGYPT ATEB [email protected] Tel.: +203 483 13 53www.atebreefer.com Fax: +203 484 99 35

FINLAND Hijojankuja 5 [email protected] Tel.: +358 0 207 420 740www.soffco.fi Fax: +358 0 207 420 759

GERMANY DEUFRA GmbH TROISDORF

[email protected] Tel.: +49 22 41 98 340www.deufra.de Fax: +49 22 41 98 34 44

GREECE PI&MS Entreprises [email protected] HALANDRI

Tel.: +30 210 608 61 52Fax: +30 210 608 61 52

HUNGARY APAGYI TRADEIMPEX [email protected] BUDAPEST

Tel.: +36 1 223 1958Fax: +36 1 273 0680

ITALY BERNARD SERVOMOTORI [email protected] RHO /MILANO

Tel.: +39 02 931 85 233Fax: +39 02 931 85 260

MALAYSIA ACTUATION & CONTROLS [email protected] JOHOR BAHRU

Tel.: +60 7 23 50 277 / 23 50 281Fax: +60 7 23 50 280 / 23 50 285

MIDDLE-EAST BERNARD [email protected] DUBAI - U.A.E.

Tel.: +971 4 39 80 726Fax: +971 4 39 80 726

MOROCCO AQUATEL [email protected] CASABLANCA

Tel.: +212 22 66 55 71Fax: +212 22 66 55 74

NETHERLANDS BERNARD BENELUX [email protected] AN ZWAAG

Tel.: +31 (0)229-298083Fax: +31 (0)229-298089

NORWAY FAGERBERG NORGE [email protected] GRESSVIKwww.fagerberg.no Tel.: +47 69 35 55 30

Fax: +47 69 35 55 31

POLAND [email protected] WARSAW

Tel.: +48 22 864 55 43Fax: +48 22 864 94 22

PORTUGAL PINHOL, GOMES & GOMES [email protected] CARNAXIDE

Tel.: +351 21 425 68 50Fax: +351 21 425 68 59

RUSSIA BERNARD REPRESENTATIVE OFFICE [email protected] c/o AMOTEK - MOSCOW

Tel./Fax: +7 (495) 343 43 80Mob.: +7 917 562 8591

RUSSIA (agent) A.E.T. [email protected] ST PETERSBURG

Tel./Fax: +7 812 320 55 97Mob.: +7 812 956 35 14

SINGAPORE ACTUATION & CONTROLS ENG. (ASIA)[email protected] SINGAPORE

Tel.: +65 65 654 227Fax: +65 65 650 224

SPAIN BERNARD [email protected] MADRID

Tel.: +34 91 30 41 139Fax: +34 91 32 73 442

SOUTH AFRICA A-Q-RATE AUTOMATION [email protected] BERTSHAM

Tel.: +27 11 432 58 31Fax: +27 11 432 41 04

SOUTH KOREA RENTEC CO Ltd (water market) [email protected] Tel.: +82 31 399 73 23

Fax: +82 31 399 80 77

SOUTH KOREA YOO SHIN E&I Co. Ltd (oil & gas market) SEOUL [email protected] Tel.: +82 2 406 62 78

Fax: +82 2 406 62 79

SWITZERLAND MATOKEM AG [email protected] ALLSCHWILwww.matokem.ch Tel.: +41 61 483 15 40

Fax: +41 61 483 15 42

THAILAND BERNARD SOUTH-EAST [email protected] BANGKOK

Tel.: +66 2 640 82 64Fax: +66 2 640 82 60

TURKEY OTKONSAS [email protected] ISTANBUL

Tel.: +90 216 326 39 39Fax: +90 216 545 98 75 /76

UNITED ARABS EMIRATES EMIRATES [email protected] ABU DHABI

Tel.: +97 12 644 73 73Fax: +97 12 644 40 66

UNITED-KINGDOM ZOEDALE Plc [email protected] BEDFORDwww.bernardactuators.co.uk Tel.: +44 12 34 83 28 28

Fax: +44 12 34 83 28 29

USA ENERTECH(nuclear applications) [email protected] Tel.: (714) 528-2301 x247

USA/CANADA/MEXICO BERNARD CONTROLS Inc(except nuclear applications) HOUSTON - [email protected] Tel.: +1 281 578 66 66www.bernardcontrols.com Fax: +1 281 578 27 97