november 2011 surveyor central system medica 2011

9
November 2011 Surveyor Central System Medica 2011

Upload: timothy-phillips

Post on 02-Jan-2016

218 views

Category:

Documents


1 download

TRANSCRIPT

November 2011

Surveyor Central System

Medica 2011

Surveyor Central Features at a Glance

• Windows XP based with easy-to-use menus• Surveyor network for up to 80 telemetry channels• Antenna network option for increased coverage• Diagnostic 12-lead patient monitoring!

Ischemia and infarction patterns are not missed • ST segment analysis in all 12 leads

ST segment change alarms• SpO2% and pulse rate display with on/off pleth waveform display• Arrhythmia monitoring with alarm events

Standard lethal arrhythmias (e.g. VT, VF, Arrest) Extended arrhythmias (e.g. ectopy, R-on-T, irregularity, etc.) SpO2 (thresholds, desaturation) Resting ECG (QT prolongation) ST change Patient call Technical events

• 12-lead ECG interpretation with VERITAS™ analysis No need to connect to an electrocardiograph

• Protocol manager for automatic operation Automatic timed events for therapies Automatic ECG printouts with protocol message

• Full disclosure for beat-by-beat review and storage Ability to review and print ECG during and after monitoring Ability to review graphical and tabular trending Ability to import monitoring data for Holter analysis

• Repeat monitoring display in networked locations with Surveyor Repeater

• Duplicate control of patient monitoring slots Multiple control at any number of locations

• Remote review capabilities Online patient monitoring data review Archived patient monitoring data review Choice of turnkey or software only

Surveyor Central Features at a Glance

Telemetry Benefit: No Clutter!

3-channel telemetry Pulse oximetry monitor 3-channel Holter monitor

ECG machine

From this (competitor’s equipment) To a single device

T12S 12-Lead ECG Transmitter with SpO2

Real-time12-lead telemetry, pulse oximetry, 12-lead

ECG, and 12-lead Holter all in one device!

Continuous 12-Lead ECG Capture

Click on any channel to immediately display 12-lead ECG and all parameters.

Ease of use: point and click!

Presentation of ST Changes

Averaged ECG shows ST change.

Continuous 12-lead ST trending.

ST Change report printout

Full Disclosure Storage and Review

• Immediate event review All 12-leads Any single or combination of leads

• Navigation to Any time point Any alarm event Any Protocol event

• Print and Export ECGs from full disclosure • Export to HScribe for Holter analysis• 600 patient monitoring days of storage

Trend Review and Print

User-defined Graphical Trend

User-defined Tabular Trend

Automatic Operation

Onscreen timers show protocol start time and therapy progression:Time in current stage

Time to next stage

Next stage name

Protocol Manager events are displayed in the multi-patient view and can be selected in “Review”.