normal icat samples labeled (2 hrs) and trypsin- digested (overnight) at 37°c samples...

1
Normal ICAT Samples labeled (2 hrs) and trypsin-digested (overnight) at 37°C Samples cleaned/purified as above, and cleaved (2 hrs) at 37°C Kratos Axima MALDI-TOF Digests C 18 zip-tipped and eluted with 2mg/mL HCCA in 90%AcCN, 0.1% TFA on hydrophobic probe ABI Q-STAR/LC-MS/MS Digests seperated on a Swift C 18 column (150 µm i.d. x 5 cm, 5 µm particle size), 250 min separation--6-35% B Analyzed positive ion mode, 1 sec MS scan, 3 sec MS/MS scan, 2.6 kV ProICAT Analysis ABI ProICAT software was Introduction: The power of combining cleavable ICAT (isotope-coded affinity tags) and CEM microwave technologies offers a more efficient, high- throughput analysis of differential quantitation and identification in both simple and complex protein mixtures. The time required to process ICAT- labeling protocols has been reduced from 10 + hours to 30 minutes. The technique has been applied to both BSA for validation and depleted rat serum. Here we demonstrate the successful labeling and identification of 76 proteins from depleted serum. Conclusions: The time required for cleavable-ICAT analysis has been reduced from 10 + hours to 30 minutes. The combination of depletion and microwave-assisted ICAT enhances low abundant protein ID’s. 76 proteins were identified with a confidence of >64 using ABI ProICAT software. Future Work: • Application of ABI iTRAQ labels to biological samples. • Comparison of the relative efficiency of microwave-labeling to normal labeling. Increase the number of depleted proteins from serum/plasma samples and pre- fractionation prior to analysis to increase low abundant protein ID’s. Methods: Depletion Sprague dawley rat serum was depleted of RSA-IgG- Transferrin ABI vision system Avian IgY antibodies Ultralink TM hydrazide beads Microwave-ICAT CEM DiscoverO’ microwave system Samples were microwave- labeled with light (C 12 ) or heavy (C 13 ) biotinylated labels (10 min) • Labeled fractions were mixed 1:1 and 1:2 Samples were microwave- digested with trypsin (10 min), cleaned via cation- exchange, purified on an avidin cartridge, and microwave-cleaved of biotin Fig. 1: MALDI spectra of normal and CEM-labeled laminin peptide. Fig. 2: MALDI spectra of CEM-labeled and normal-labeled BSA; 1:1 light:heavy. Results: Fig. 4: MS spectrum of corresponding light and heavy peptides. Higher-throughput Cleavable ICAT Analysis using Microwave Technology Tonya M. Pekar, Mai-Loan Nguyen, Jennifer Rutherford, David Innamorati, Joe Bonapace, and John Pirro Charles River Proteomic Services, Worcester, MA Standard 2 Hr Labeling and Cleaving Un-cleaved Laminin Cleaved Laminin 10 min CEM Labeling and Cleaving Cleaved Laminin Un-cleaved Laminin Fig. 5: MS/MS spectrum of light-labeled peptide; fragments used to ID parent protein and identify label. Fig. 3: TIC of depleted rat serum, with 1:1 CEM-labeled light:heavy peptides. Un-Labeled Peptide (2Hr labeling) Un-Labeled Peptide (10 min labeling) Normal 1:1 Normal 1:1 CEM 1:1 CEM 1:1 Fig. 6: Example of the protein identification and quantitation output of ProICAT software used for analysis of the data dependent scans. 76 protein identifications were made from MS/MS of cysteine-labeled peptides, confidence >64. A ccession # Nam e C onfidence P eptides Found A vg H :L gi|125520 T-K IN INO G EN IPRECURSO R 99 31 0.8402 gi|1345834 C-REACTIVE PRO TE IN P R E C U R S O R 99 3 0.9576 gi|130318 P LA S M INO G EN PRECURSO R 99 2 0.9567 gi|2497917 ZIN C -ALPH A-2-G LY C O PRO TE IN P R E C U R S O R 99 1 1.0339 gi|1730193 UDP-G LU C O S E 4-E P IM ERASE 95 1 0.7502 Zoom Full Range

Upload: teresa-cummings

Post on 28-Dec-2015

212 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Normal ICAT Samples labeled (2 hrs) and trypsin- digested (overnight) at 37°C Samples cleaned/purified as above, and cleaved (2 hrs) at 37°C Kratos Axima

Normal ICAT• Samples labeled (2 hrs) and trypsin-

digested (overnight) at 37°C • Samples cleaned/purified as above, and

cleaved (2 hrs) at 37°C Kratos Axima MALDI-TOF • Digests C18 zip-tipped and eluted with

2mg/mL HCCA in 90%AcCN, 0.1% TFA on hydrophobic probe

ABI Q-STAR/LC-MS/MS• Digests seperated on a Swift C18 column

(150 µm i.d. x 5 cm, 5 µm particle size), 250 min separation--6-35% B

• Analyzed positive ion mode, 1 sec MS scan, 3 sec MS/MS scan, 2.6 kV

ProICAT Analysis• ABI ProICAT software was used for

analysis of the data dependent scans

Introduction:

The power of combining cleavable ICAT (isotope-coded affinity tags) and CEM microwave technologies offers a more efficient, high-throughput analysis of differential quantitation and identification in both simple and complex protein mixtures. The time required to process ICAT-labeling protocols has been reduced from 10+ hours to 30 minutes. The technique has been applied to both BSA for validation and depleted rat serum. Here we demonstrate the successful labeling and identification of 76 proteins from depleted serum.

Conclusions:• The time required for cleavable-ICAT analysis has been reduced from 10+ hours to 30 minutes.• The combination of depletion and microwave-assisted ICAT enhances low abundant protein ID’s.• 76 proteins were identified with a confidence of >64 using ABI ProICAT software.

Future Work:• Application of ABI iTRAQ labels to biological samples.• Comparison of the relative efficiency of microwave-labeling to normal labeling.• Increase the number of depleted proteins from serum/plasma samples and pre-fractionation prior to analysis to

increase low abundant protein ID’s.

Methods:

Depletion• Sprague dawley rat serum was depleted of

RSA-IgG-Transferrin• ABI vision system• Avian IgY antibodies• UltralinkTM hydrazide beadsMicrowave-ICAT• CEM DiscoverO’ microwave system• Samples were microwave-labeled with

light (C12) or heavy (C13) biotinylated labels (10 min)

• Labeled fractions were mixed 1:1 and 1:2• Samples were microwave-digested with

trypsin (10 min), cleaned via cation-exchange, purified on an avidin cartridge, and microwave-cleaved of biotin (10 min)

CEM DiscoverO’ Protocol• 10 minute digest• Max power: 50 W• Max temp: 60ºC• 10% cooling

Fig. 1: MALDI spectra of normal and CEM-labeled laminin peptide.

Fig. 2: MALDI spectra of CEM-labeled and normal-labeled BSA; 1:1 light:heavy.

Results:

Fig. 4: MS spectrum of corresponding light and heavy peptides.

Higher-throughput Cleavable ICAT Analysis using Microwave Technology

Tonya M. Pekar, Mai-Loan Nguyen, Jennifer Rutherford, David Innamorati, Joe Bonapace, and John Pirro

Charles River Proteomic Services, Worcester, MA

Standard 2 Hr Labeling and Cleaving Un-cleaved Laminin

Cleaved Laminin

10 min CEM Labeling and Cleaving Cleaved Laminin Un-cleaved Laminin

Fig. 5: MS/MS spectrum of light-labeled peptide; fragments used to ID parent protein and identify label.

Fig. 3: TIC of depleted rat serum, with 1:1 CEM-labeled light:heavy peptides.

Un-Labeled Peptide(2Hr labeling)

Un-Labeled Peptide(10 min labeling)

Normal 1:1

Normal 1:1

CEM 1:1

CEM 1:1

Fig. 6: Example of the protein identification and quantitation output of ProICAT software used for analysis of the data dependent scans. 76 protein identifications were made from MS/MS of cysteine-labeled peptides, confidence >64.

Accession # Name Confidence Peptides Found Avg H:Lgi|125520 T-KININOGEN I PRECURSOR 99 31 0.8402gi|1345834 C-REACTIVE PROTEIN PRECURSOR 99 3 0.9576gi|130318 PLASMINOGEN PRECURSOR 99 2 0.9567gi|2497917 ZINC-ALPHA-2-GLYCOPROTEIN PRECURSOR 99 1 1.0339gi|1730193 UDP-GLUCOSE 4-EPIMERASE 95 1 0.7502

Zoom

Full Range