norandex 1/4” extruded polystyrene foam …when residing a home, the old siding must be covered...

6
Caution: This roofing underlayment is combustible Protect from high heat sources. 1/4 inch Nominal Thickness R-1.0 NORANDEX 1/4” EXTRUDED POLYSTYRENE FOAM INSULATION UNITED STATES | PRODUCT/INSTALLATION INFORMATION | RESIDENTIAL NORANDEX 1/4” Insulation is an extruded polystyrene (XPS) foam insulation board fanfolded for easy installation over existing exterior surfaces. It is used as a rigid foam underlayment for new siding materials. It also features a straight cut hinge, allowing the cladding to lie flat. NORANDEX 1/4” is a nominal 1/4” thick extruded polystyrene board and is produced in continuous 4’ x 48’ fanfolded sections with 24” crimped-seam spacing. NORANDEX 1/4” provides sealing effectiveness and a smooth level surface for new siding. NORANDEX 1/4” Insulation meets ASTM C578, Type IV – Standard Specification for Rigid Cellular Polystyrene Thermal Insulation. NORANDEX 1/4” Insulation meets IRC requirements for foam plastic insulation. Features and Benefits of NORANDEX 1/2 ” EXTRUDED POLYSTYRENE FOAM INSULATION Feature Benefit Straight cut hinge Allows cladding to lie flat Continuous fanfolded sections Covers wall studs and cavity, enhancing thermal efficiency and moisture management Flat seams Simplifies installation over old siding Built Green Norandex supports initiatives that help preserve our environment, and we strive for environmental sensitivity in our manufacturing processes and in our products. Norandex insulating foams: • contain no VOCs* • are formaldehyde-free • are not a known food source for mold or insects • are recyclable (extruded polystyrene)

Upload: others

Post on 06-Jun-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: NORANDEX 1/4” EXTRUDED POLYSTYRENE FOAM …When residing a home, the old siding must be covered with an “underlayment,” ensuring a solid, level surface to back up new siding

Caution: This roofing underlayment is combustibleProtect from high heat sources.

1

1/4 inch Nominal Thickness

R-1.0

NORANDEX 1/4” EXTRUDED POLYSTYRENE FOAM INSULATION

UNITED STATES | PRODUCT/INSTALLATION INFORMATION | RESIDENTIAL

NORANDEX 1/4” Insulation is an extruded polystyrene (XPS) foam insulation board fanfolded for easy installation over existing exterior surfaces. It is used as a rigid foam underlayment for new siding materials. It also features a straight cut hinge, allowing the cladding to lie flat.

NORANDEX 1/4” is a nominal 1/4” thick extruded polystyrene board and is produced in continuous4’ x 48’ fanfolded sections with 24” crimped-seam spacing.NORANDEX 1/4” provides sealing effectiveness and a smooth level surface for new siding.

NORANDEX 1/4” Insulation meets ASTM C578, Type IV – Standard Specification for Rigid Cellular Polystyrene Thermal Insulation.

NORANDEX 1/4” Insulation meets IRC requirementsfor foam plastic insulation.

Features and Benefits of NORANDEX 1/2” EXTRUDED POLYSTYRENE FOAM

INSULATIONFeature BenefitStraight cut hinge Allows cladding to lie flat

Continuous fanfolded sections Covers wall studs and cavity, enhancing thermal efficiency and moisture management

Flat seams Simplifies installation over old siding

Built GreenNorandex supports initiatives that help preserve our environment, and we strive for environmental sensitivity in our manufacturing processes and in our products. Norandex insulating foams:• contain no VOCs* • are formaldehyde-free• are not a known food source for mold or insects • are recyclable (extruded polystyrene)

Page 2: NORANDEX 1/4” EXTRUDED POLYSTYRENE FOAM …When residing a home, the old siding must be covered with an “underlayment,” ensuring a solid, level surface to back up new siding

INSTALLATIONBefore covering a wall with insulation and new siding, make sure the wall is sound. Do not install siding over walls that have deteriorated from moisture, insects or other causes.

1. Cover the exterior surface completely with NORANDEX 3/8” Insulation. Butt the board edges tightly together. After measuring, score panels with a utility knife, then snap off the excess over the edge of the work surface.

2. Measure the combined thickness of the insulation and new siding. Use this measurement to determine the thickness of the door and window jamb extensions. Extend flashings. The sills may also need to be extended. Have a qualified electrician extend outlets, light fixtures, doorbell buttons and other electrical items.

3. Align the fanfolded boards along the bottom edge of the home or with the siding starter strip.

4. Nail boards directly over existing surface. Use nails recommended for cladding product. Make sure nails go through the insulation, the existing surface and into the framing. This nailing pattern serves as a guide when driving the cladding nails later on. Do notoverdrive nails. This can crush the insulation and can also cause a wavy siding installation.

5. Tape all joints with construction tape (2-7/8” wide).

6. Apply cladding and trim. Use nails recommended for cladding product. Be sure nails go through the insulation, existing surface and into the framing.

7. Follow the cladding manufacturer’s installationinstructions.

Typical Physical Properties ofNORANDEX 1/4” EXTRUDED POLYSTYRENE FOAM INSULATION

Property and Test Method ValueThermal Resistance @ 1/4", ASTM C518 @ 75°F mean temp., ft2•h•°F/Btu, R-value(1), min. 3/8” = R-1

Density, ASTM D1622 Fresh, foam core only, min. Fresh, foam core, max.

1.92.9

Flame Spread(2), ASTM E84 10Smoke Developed, ASTM E84 200(1) R means resistance to heat flow. The higher the R-value, the greater the insulating power.(2) This numerical flame spread rating is not intended to reflect hazards presented by this or any other material under actual fire conditions.

1 ABC Parkway, Beloit, WI 53511 | www.norandex.com

Page 3: NORANDEX 1/4” EXTRUDED POLYSTYRENE FOAM …When residing a home, the old siding must be covered with an “underlayment,” ensuring a solid, level surface to back up new siding

Caution: This roofing underlayment is combustibleProtect from high heat sources.

3/8 inch Nominal Thickness

R-1.5

NORANDEX 3/8” EXTRUDED POLYSTYRENE FOAM INSULATION

UNITED STATES | PRODUCT/INSTALLATION INFORMATION | RESIDENTIAL

NORANDEX 3/8” Insulation is an extruded polystyrene (XPS) foam insulation board fanfolded for easy installation over existing exterior surfaces. It is used as a rigid foam underlayment for new siding materials. It also features a straight cut hinge, allowing the cladding to lie flat.

NORANDEX 3/8” is a nominal 3/8” thick extruded polystyrene board and is produced in continuous4’ x 48’ fanfolded sections with 24” crimped-seam spacing.NORANDEX 3/8” provides sealing effectiveness and a smooth level surface for new siding.

NORANDEX 3/8” Insulation meets ASTM C578, Type IV – Standard Specification for Rigid Cellular Polystyrene Thermal Insulation.

NORANDEX 3/8” Insulation meets IRC requirementsfor foam plastic insulation. May be used as alternative water-resistive barrier as prescribed in Section 1404.2 of the IBC., Section 703.2 of the IRC, and Section 1402.1 UBC, when installed on exterior walls as described in this section.

Features and Benefits of NORANDEX 3/8” EXTRUDED POLYSTYRENE FOAM INSULATION

Feature BenefitStraight cut hinge Allows cladding to lie flat

Continuous fanfolded sections Covers wall studs and cavity, enhancing thermal efficiency and moisture management

Flat seams Simplifies installation over old siding

Built GreenNorandex supports initiatives that help preserve our environment, and we strive for environmental sensitivity in our manufacturing processes and in our products. Norandex insulating foams:• contain no VOCs* • are formaldehyde-free • are not a known food source for mold or insects • are recyclable (extruded polystyrene)

Page 4: NORANDEX 1/4” EXTRUDED POLYSTYRENE FOAM …When residing a home, the old siding must be covered with an “underlayment,” ensuring a solid, level surface to back up new siding

INSTALLATIONBefore covering a wall with insulation and new siding, make sure the wall is sound. Do not install siding over walls that have deteriorated from moisture, insects or other causes.

1. Cover the exterior surface completely with NORANDEX 3/8” Insulation. Butt the board edges tightly together. After measuring, score panels with a utility knife, then snap off the excess over the edge of the work surface.

2. Measure the combined thickness of the insulation and new siding. Use this measurement to determine the thickness of the door and window jamb extensions. Extend flashings. The sills may also need to be extended. Have a qualified electrician extend outlets, light fixtures, doorbell buttons and other electrical items.

3. Align the fanfolded boards along the bottom edge of the home or with the siding starter strip.

4. Nail boards directly over existing surface. Use nails recommended for cladding product. Make sure nails go through the insulation, the existing surface and into the framing. This nailing pattern serves as a guide when driving the cladding nails later on. Do notoverdrive nails. This can crush the insulation and can also cause a wavy siding installation.

5. Tape all joints with construction tape (2-7/8” wide).

6. Apply cladding and trim. Use nails recommended for cladding product. Be sure nails go through the insulation, existing surface and into the framing.

7. Follow the cladding manufacturer’s installationinstructions.

Typical Physical Properties ofNORANDEX 3/8” EXTRUDED POLYSTYRENE FOAM INSULATION

Property and Test Method ValueThermal Resistance @ 3/8", ASTM C518 @ 75°F mean temp., ft2•h•°F/Btu, R-value(1), min. 3/8” = R-1.5

Density, ASTM D1622 Fresh, foam core only, min. Fresh, foam core, max.

1.92.9

Flame Spread(2), ASTM E84 10Smoke Developed, ASTM E84 200(1) R means resistance to heat flow. The higher the R-value, the greater the insulating power.(2) This numerical flame spread rating is not intended to reflect hazards presented by this or any other material under actual fire conditions.

1 ABC Parkway, Beloit, WI 53511 | www.norandex.com

Page 5: NORANDEX 1/4” EXTRUDED POLYSTYRENE FOAM …When residing a home, the old siding must be covered with an “underlayment,” ensuring a solid, level surface to back up new siding

NORANDEX 1/2” EXTRUDED POLYSTYRENE FOAM INSULATION

UNITED STATES | RESIDENTIAL

NORANDEX 1/2” Extruded Polystyrene Foam Insulation provides the moisture resistance and air barrier advantages of thicker insulations, at a more affordable price. When the insulation value of a thicker product is not required, NORANDEX 1/2” insulation is an excellent choice for use with vinyl, steel or aluminum siding.

NORANDEX 1/2” Extruded Polystyrene Foam Insulation is a specially formulated 1/2” extruded polystyrene board sealed between select facing materials, and produced in continuous 24’ by 4’ fanfold sections. Available with a durable film, NORANDEX 1/2” insulation can meet high-performance requirements in residential structures, and is appropriate for:

• Residing applications• New frame wall construction behind siding

Perfect for ResidingWhen residing a home, the old siding must be covered with an “underlayment,” ensuring a solid, level surface to back up new siding materials. Using NORANDEX 1/2” ExtrudedPolystyrene Foam Insulation can help boost your home’s insulation efficiency as well as enhance the appearance of your new siding.

Caution: This roofing underlayment is combustibleProtect from high heat sources.

1/2 inch Nominal Thickness

R-2.5

Caution: This roofing underlayment is combustibleProtect from high heat sources.

1

1/2 inch Nominal Thickness

R-2.5

Typical Physical Properties ofNORANDEX 1/2” EXTRUDED POLYSTYRENE FOAM INSULATION

Property and Test Method ValueThermal Resistance @ 1/2", ASTM C518 @ 75°F mean temp., ft2•h•°F/Btu, R-value(1), min. R 2.5

Minimum Compressive Strength (5) 31.5Density, ASTM D1622 Fresh, foam core only, min. Fresh, foam core, max.

2.22.7

Flame Spread(2)(3), ASTM E84 0#Smoke Developed(4), ASTM E84 10#(1) R means resistance to heat flow. The higher the R-value, the greater the insulating power.(2) This numerical flame spread rating is not intended to reflect hazards presented by this or any other material under actual fire conditions.(3) Installed in a thickness, or stored in an effective thickness, as indicated, for a density of 2.5 pcf.(4) Flame spread and smoke developed recorded while material remained in original test position. Ignition of molten residue on the furnace floor resulted in flame travel equivalent to calculated flame spread classification of 10 and smoke developed classification of 450 to over 500.(5) Compressive strength is measured at 10 percent deformation or at yield, whichever occurs first.

Page 6: NORANDEX 1/4” EXTRUDED POLYSTYRENE FOAM …When residing a home, the old siding must be covered with an “underlayment,” ensuring a solid, level surface to back up new siding

Whether Residing or Building NewNORANDEX 1/2”

GETS THE JOB DONE RIGHT

Ideal for New ConstructionNORANDEX 1/2” Extruded Polystyrene Foam Insulation offers superior performance in new residential construction. It provides an economical alternative to other sheathing products that can absorb water or degrade.

BenefitsHomes built with NORANDEX 1/2” Extruded Polystyrene Foam Insulation offer homeowners increased energy efficiency, while the product’s ease of use and low cost help builders work better and more profitably.

Energy SavingsThe superior characteristics of NORANDEX 1/2” Extruded Polystyrene Foam Insulation (air infiltration, insulation performance, vapor permeability and moisture resistance) help homes stay warmer in winter and cooler in summer, free from air leaks that can cause up to 40 percent of normal heat loss or gain.

Ease of InstallationNORANDEX 1/2” Extruded Polystyrene Foam Insulation is lightweight and easy to cut and install. NORANDEX 1/2” represents the equivalent of three 4’ x 8’ sheets.

May be used as alternative waterresistive barrier as prescibed in Section 1404.2 of the IBC, Section 703.2 of the IRC, and Section 1402.1 UBC, when installed on exterior walls as described in this section.

Built GreenNorandex supports initiatives that help preserve our environment, and we strive for environmental sensitivity in our manufacturing processes and in our products. Norandex insulating foams:• contain no VOCs* • are formaldehyde-free • are not a known food source for mold or insects • are recyclable (extruded polystyrene)

1 ABC Parkway, Beloit, WI 53511 | www.norandex.com