noaa environmental technology laboratory gary a. wick observed differences between infrared and...
DESCRIPTION
NOAA Environmental Technology Laboratory Gary A. Wick Potential Microwave Error Contributions 3-D look-up table considering wind speed, SST, and water vaporTRANSCRIPT
Gary A. Wick NOAA Environmental Technology Laboratory
Observed Differences BetweenInfrared and Microwave Products
Detailed comparisons between infrared and microwave SST products show complex spatial and temporal differences.
Gary A. Wick NOAA Environmental Technology Laboratory
Data Sources
• Infrared– AVHRR
• Operational NLSST - Naval Oceanographic Office
• Microwave– TRMM Microwave Imager (TMI)
• Remote Sensing Systems – Wentz and Gentemann
• Buoys– QC’d GTS buoys via NCEP/CDC
Gary A. Wick NOAA Environmental Technology Laboratory
Potential Microwave Error Contributions
3-D look-up table considering wind speed, SST, and water vapor
Gary A. Wick NOAA Environmental Technology Laboratory
Estimated Microwave Bias
Gary A. Wick NOAA Environmental Technology Laboratory
Stability Impact
Gary A. Wick NOAA Environmental Technology Laboratory
Potential Infrared Error Contributions
2-D look-up table considering water vapor and SST
Gary A. Wick NOAA Environmental Technology Laboratory
Estimated Infrared Bias
Gary A. Wick NOAA Environmental Technology Laboratory
Infrared Aerosol Error Contributions
• Derived from matches with TMI
Gary A. Wick NOAA Environmental Technology Laboratory
Impact of Bias Corrections
Bias: 0.21 K
STD: 0.44 K
Bias: -0.02 K
STD: 0.27 K
Gary A. Wick NOAA Environmental Technology Laboratory
Impact on OI Analysis
August 2000
• No Corrections– bias: 0.08 K– rms: 0.61 K
• With Corrections– bias: -0.01– rms: 0.59
Gary A. Wick NOAA Environmental Technology Laboratory
New Humidity and Temperature Products
• Produced new near-surface specific humidity and air temperature products
• Combination of SSM/I and AMSU• Retrieval derived through regression to cruise
observations
Gary A. Wick NOAA Environmental Technology Laboratory
What Factors Explain the Differences
• Simple linear correlation analysis• Quantities readily in MW products + Ta/qa
• Leading terms qs-qa and Ts-Ta
• Applies to both TMI and MCSST• Highly sensitive to choice of surface
temperature
Gary A. Wick NOAA Environmental Technology Laboratory
TMI Results
Gary A. Wick NOAA Environmental Technology Laboratory
MCSST Results
Gary A. Wick NOAA Environmental Technology Laboratory
Additional MCSST Impact
Gary A. Wick NOAA Environmental Technology Laboratory