nist-f1 cesium fountain atomic clock the primary time and frequency standard for the united states ...

9

Upload: hollie-arline-sutton

Post on 02-Jan-2016

228 views

Category:

Documents


8 download

TRANSCRIPT

Page 1: NIST-F1 Cesium Fountain Atomic Clock The Primary Time and Frequency Standard for the United States  f = 9,192,631,770
Page 2: NIST-F1 Cesium Fountain Atomic Clock The Primary Time and Frequency Standard for the United States  f = 9,192,631,770

NIST-F1 Cesium Fountain Atomic ClockThe Primary Time and Frequency Standard for the United States

http://tf.nist.gov/cesium/fountain.htm

f = 9,192,631,770 Hz T ~ 10-6 K

The base unit of time is officially defined as "the duration of 9,192,631,770 periods of the radiation corresponding to the transition between the two hyperfine levels of the ground state of the caesium-133 atom".

Page 3: NIST-F1 Cesium Fountain Atomic Clock The Primary Time and Frequency Standard for the United States  f = 9,192,631,770

http://inms-ienm.nrc-cnrc.gc.ca/research/cesium_clock_e.html

Cesium 133 energy diagram

Page 4: NIST-F1 Cesium Fountain Atomic Clock The Primary Time and Frequency Standard for the United States  f = 9,192,631,770

Commercial standard: 1 in 1012 accuracy

Page 5: NIST-F1 Cesium Fountain Atomic Clock The Primary Time and Frequency Standard for the United States  f = 9,192,631,770

Cesium Beam Clock Cesium Fountain Clock

» Hot atoms, heated in oven to ~350K

» Cold atoms, laser cooled to ~2 x 10-6K

» Horizontal launch at ~250m/s (velocity of gaseous cesium atoms at 350K)

» Vertical launch at 2 to 5 m/s (by laser beams)

» Using magnets, atoms in two atomic ground states are separated. Atoms in the desired state enter the microwave cavity; the other atoms are discarded.

» The atoms are all pumped (using laser pumping) into the desired state. All atoms enter the microwave cavity.

» The atoms undergo Ramsey interrogation as they pass through the two parts of the double cavity. Interrogation time: 0.005 s

» The atoms pass through the same microwave cavity on their way up and way down, undergoing Ramsey interrogation. Interrogation time: 0.5 s

» Continuous flow of atoms » Pulsed operation

Page 6: NIST-F1 Cesium Fountain Atomic Clock The Primary Time and Frequency Standard for the United States  f = 9,192,631,770
Page 7: NIST-F1 Cesium Fountain Atomic Clock The Primary Time and Frequency Standard for the United States  f = 9,192,631,770
Page 8: NIST-F1 Cesium Fountain Atomic Clock The Primary Time and Frequency Standard for the United States  f = 9,192,631,770
Page 9: NIST-F1 Cesium Fountain Atomic Clock The Primary Time and Frequency Standard for the United States  f = 9,192,631,770