nisse i injection moulding machines op

Upload: web312tw

Post on 13-Apr-2018

219 views

Category:

Documents


0 download

TRANSCRIPT

  • 7/27/2019 Nisse i Injection Moulding Machines Op

    1/2

    Injection MouldingOperating Procedure

    Note: The Nissei ES2000 Injection Molding Machine has several switches andbuttons, and also has a touch screen. To minimize confusion in distinguishing between

    which buttons are located in which positions on the machine, the buttons and switches are

    divided into three categories:

    [ ] these brackets indicate a button that is located on the panel

    < > these brackets indicate a switch that is turned clockwise orcounterclockwise

    ( ) these brackets indicate a button that is located on the touch screen

    Startup Procedure

    1. Turn on the machine by turning the key switch to the On position.2. Sign in by entering name, email, material, etc. in the log book.3. Turn on the key switch, which is located on the lower right side of the

    machine.4. Turn on cooling water to the machine by switching the correct valve to the

    open position. It is very important to remember to turn the cooling water on,

    as the high temperature of the machine could melt the polymer before itactually enters the heating chamber, resulting in a blockage in the barrel.

    5. Turn on the operating power by pressing the orange [OPER POWER] buttonlocated on the lower right side of the panel. The button should light up if the

    machine is actually receiving power. If it doesnt, see Steve Hodgson and ask

    him to turn on the power switch, and try again.

    6. After about 20 seconds the machine will start up and the touch screen willdisplay an image. You must now ensure that the proper operating program is

    loaded for the polymer that you are working with (TEST_PE for polyethylene

    or TEST_PP for polypropylene). Push [DATA CHANGE] to view whichprogram is currently loaded and to see a list of all other available programs.

    To load a new program, click on the icon in the upper left side of the touch

    screen that looks like a filing cabinet (this means that you are going to load aprogram from the systems hard drive, as opposed to a floppy disk). Scroll up

    and down the screen by pushing the directional arrows on the panel. Once the

    proper program is selected, load it by pressing (CONFIRM).7. Ensure that the machine is set to heat to the desired temperature. Push

    [TEMP] to access the temperature profile of the heating barrel. If the

    temperatures indicated are not correct, they can be changed by touching the

    temperature location (nozzle, front, middle, rear) and input the newtemperature using the number pad on the panel. Temperatures should be at

    least 50oC above the melting temperature for the polymer.

  • 7/27/2019 Nisse i Injection Moulding Machines Op

    2/2

    8. Ensure that all switches are in the neutral position (indicated by o), and thatthe machine is set to operate manually (indicated by a hand icon ).

    9. Turn on the heater and motor power by pressing the orange [MOTORPOWER] and [HEATER POWER] buttons near the [OPER POWER] button.

    NOTE: It is very important that the machine is not re-started within 60 s of a

    shutdown. Doing so could cause a surge in power, destroying all electronicson the machine. See attached file.

    10.Wait 40 minutes for the machine to heat up.

    Operating Procedure

    1. Open hopper supply gate to allow polymer pellets to enter the heating barrel.2. Ensure that the injection unit is positioned away from the mold. If it is not,

    manually move it by turning the switch to the BWDposition. Once the unit stops moving, return the switch to the neutral position.

    3. Purge the extruder by pressing the [PURGE] button once. Once the purge hasstopped, push the [PURGE] button again to turn off the purge function andwipe off the end of the nozzle. CAUTION: The purged polymer is very hot!

    Allow it cool before removing it from underneath the injection unit.

    4. Align the screw before beginning a mold by pressing and holding the[SCREW MOTOR] button until the screw stops turning.

    5. Check the settings of all controlled variables (times, pressures, velocities, etc.)to ensure that they are at desired levels.

    6. Ensure that operation safety door is closed. If not, an alarm will sound whenmolding begins.

    7. The machine is now ready to begin molding. To run the machine, turn the[OPERATION] switch from manual to single-cycle automatic mode .

    8. Operational variables can now be manipulated. For a list of what variables canbe manipulated and how to manipulate them, see below.

    Shutdown Procedure

    1. Turn the machine into manual mode by turning the [OPERATION] switchfrom automatic to manual .

    2. Turn the [INJECTION UNIT] to the BWD position to move the extruderaway from the mold.

    3. Close the hopper gate.4. Purge the barrel until empty.5. Turn off the heater, motor, and operating power by pressing the orange

    [OPER POWER], [MOTOR POWER], and [HEATER POWER] buttons.

    6. Turn off the cooling water.7. Turn key switch to the Off position.8. Clean up all material and sign out in the log book.