nicote cable glands catalogue

Upload: kvp0107

Post on 30-Oct-2015

320 views

Category:

Documents


1 download

DESCRIPTION

Cable glands of all types

TRANSCRIPT

  • Cable Glands Catalogue

  • Thomas & Betts Nylon Cable Glands are quick & easy to install with a high quality gripping claw/seal arrangement that caters

    for a wide range of cable sizes per fitting. Each gland has no loose parts and requires no disassembly for cable installation.

    LOCKNUT WASHER BODY CLAW SEALS NUT

    ACRO

    SS C

    ORN

    ERS

    CABL

    EOV

    ERAL

    LM

    AX

    MOUN

    TING

    THRE

    AD

    THREADLENGTH

    NG Cable GlandGENERAL PURPOSE NYLON CABLE GLANDS

    Thomas & Betts, a global leader in the design, manufacture and marketing of electrical products and accessories is proud to be the manufacturer of the Nicote range of metal cable glands. This

    new catalogue not only details the full Nicote range, but presents the entire Thomas & Betts range of cable glands from the general purpose NG Nylon range through to 304 Stainless steel models designed to deliver superior performance in harsh environments.

    Thomas & Betts Australasia is proudly committed to delivering innovative solutions to its valued customers through experienced sales and service teams in each state and the National Cus-tomer Support Centre. Should you not find what you are looking for in this catalogue or need

    further information please contact us on 1300 666 595.

    ApplicationsIndoor and outdoor use

    StandardsAS60529-2004

    FunctionProvides seal on cable sheath

    Protection ClassIP68, Resistant to salt water, weak alcohol, oil, grease and common solvents

    ConstructionBody - UL approved Nylon 66 (Black)Seal - EPDM Rubber

    Thread TypeMetric with locknut and IP68 washer

    Part Mounting Thread Cable Acceptance Details Number Size Length Overall Diameter Across Pack (mm) (mm) Min. Max. Corners Qty. (mm) (mm) (mm)

    152227273341506275

    50 50 25

    25 25 10 10 2 2

    NG-12NG-16NG-20NG-20-2.5TPSNG-25NG-32NG-40 NG-50NG-63

    151515151515152020

    4 6

    8.52.5mm TPS

    12.518243040

    71014N/A1825324151

    M12 x 1.5 M16 x 1.5M20 x 1.5M20 x 1.5M25 x 1.5M32 x 1.5M40 x 1.5M50 x 1.5M63 x 1.5

    Product specifications may change at any time without notice.

    1

  • The Nicote range of metal cable glands are your guarantee of safety in hazardous locations especially where fire and explosion are an identified risk.

    The current Nicote range is quite simply the best available because they do not compromise on safety and thats what counts!

    Take a look at just some of the features that make Nicote the first choice:

    Highly durable nickel platingNicote glands are coated in a proprietary 2 coat plating process that ensures all metalcomponents will not degrade and potentially let you down over time.

    Comprehensive RangeThe greater the range of cable sizes a gland is designed to cover, the higher the risk of sealsfailing. Nicote contains a comprehensive range with smaller cable acceptance incrementsthat also allows the gland bodies to be smaller and hence easier to use when space is tight.

    Full ApprovalsDont just take our word for it, independent test bodies have confirmed that the Nicote gland range complies with relevant IEC and Australian standards including approvals for hazardous areas.

    Neoprene SealsAll Nicote glands use high quality Neoprene seals that retain their tension and are resistant to oil, chemicals and flame making them the best choice for hazardous applications.

    IP66/68 ProtectionAll Nicote glands classified for indoor/outdoor use are supplied with IP66/68 gaskets forinstallation on the mounting thread and neoprene seals on the cable sheath. This levelof protection means that the glands are protected from the ingress of dust and water.Anything less is unacceptable and compromises safety.

    ORing SealsAll Nicote glands designed for SWA cable and classified for indoor/outdoor use, feature oring seals between the body and sleeve to ensure that water cannot progress along the threadand compromise the seal. Just another safety feature.

    Easy to useThe ability to easily produce a tight seal and correct earth everytime is of primary importance.All Nicote glands are designed to be easy to use and to ensure that the installer can see thatthe correct fitting instructions have been followed. For example, all SWA flameproof glandsfeature a loose clamping cone so that the installer can see that the armour is fully secured.

    When safety matters, there is only one choice.

    Introduction

    2

  • MOUN

    TING

    THRE

    AD

    ACRO

    SS C

    ORN

    ERS

    CABL

    E OV

    ERAL

    L

    MAX

    BODY

    IP66/68 GASKET NEOPRENE SEAL

    SKID WASHER

    NUT

    PROTRUSIONTHREADLENGTH

    UN12AUN16AUN20AUN20BUN25AUN32AUN40A UN40BUN50A UN50B UN63AUN63B

    101010101010161616161919

    1.0 1.0 6.010.615.020.025.030.035.040.045.050.0

    6.06.010.615.020.025.030.035.040.045.050.055.0

    18.320.627.530.933.040.751.155.060.967.078.088.0

    131314161718212323242532

    1/2 x 26 TPI M16 x 1.5M20 x 1.5M20 x 1.5M25 x 1.5M32 x 1.5M40 x 1.5M40 x 1.5M50 x 1.5M50 x 1.5M63 x 1.5M63 x 1.5

    Fitting Instructions1. To comply with IP66/68 approvals, the fibre gasket must be installed on the mounting thread.2. Screw the gland body into the apparatus, or use a locknut to secure body.3. Pass the cable through the gland to the required position and tighten gland nut so that the seal grips firmly onto the cable.

    Part Mounting Thread Cable Acceptance Details Cable Gland Number Size Length Overall Diameter Across (mm) (mm) Min. Max Corners Protrusion (mm) (mm) (mm) (mm)

    UN Cable GlandGENERAL PURPOSE CABLE GLAND FOR CIRCULAR CABLE

    Product specifications may change at any time without notice.

    3

    ApplicationsIndoor and Outdoor use

    StandardsAS60529-2004

    FunctionProvides Seal on Cable Sheath

    Protection ClassIngress of waterIP66/68 (30m)

    ConstructionNickel Plated Brass Components

  • ApplicationsIndoor and Outdoor use in hazardous areas

    StandardsAS60529-2004

    FunctionProvides Flameproof Seal on Cable Sheath

    Protection ClassIngress of waterIP66/68 (40m)

    ConstructionNickel Plated Brass Components

    Fitting Instructions1. To comply with IP66/68 approvals, the fibre gasket must be installed on the mounting thread.2. Screw the gland body into the apparatus.3. Pass the cable through the gland to the required position and tighten gland nut so that the seal grips firmly onto the cable.

    PROTRUSION

    ACRO

    SS C

    ORN

    ERS

    MOUN

    TING

    THRE

    ADBODY

    CABL

    E OV

    ERAL

    LM

    AX

    IP66/68 GASKET NEOPRENE SEAL SKID WASHER

    NUT

    THREADLENGTH

    UFPN20AUFPN20BUFPN20CUFPN25AUFPN32AUFPN32BUFPN40AUFPN40BUFPN50AUFPN50BUFPN63AUFPN63BUFPN250AUFPN275AUFPN300AUFPN350AUFPN350BUFPN400AUFPN400B

    M20 x 1.5 M20 x 1.5M20 x 1.5M25 x 1.5M32 x 1.5M32 x 1.5M40 x 1.5M40 x 1.5M50 x 1.5M50 x 1.5M63 x 1.5M63 x 1.52.5BSP2.75BSP3.0BSP3.5BSP3.5BSP4.0BSP4.0BSP

    6.29.112.014.518.221.925.630.034.239.144.048.755.562.469.376.183.089.996.6

    9.112.014.518.221.925.630.034.239.144.048.755.562.469.376.183.089.996.6103.0

    28283136424652557274888898107115129129143143

    21182023232525253133343435363648484848

    303020161288622222111111

    12.712.712.715202021212828282828353538383838

    Product specifications may change at any time without notice.

    Part Mounting Thread Cable Acceptance Details Cable Gland Inner Number Size Length Overall Diameter Across Carton (mm) (mm) Min. Max. Corners Protrusion Pack (mm) (mm) (mm) (mm) Qty.

    UFPN Cable GlandFLAMEPROOF CABLE GLAND FOR CIRCULAR CABLE

    4

  • ApplicationsIndoor use

    FunctionProvides Armour Clamp

    ConstructionNickel Plated Brass Components

    Fitting Instructions1. Screw the gland body into the apparatus.2. Pass the gland sleeve over the cable before commencing to strip the outer sheath of the cable.3. Measure the length of tails required and add about 75mm to the outer sheath and armour to this point.4. Strip the outer sheath.5. Cut the armour wire to the SWA exposed length in the table.6. Pass the armour clamp over the armour.7. Pass the armour cone over the bedding and under the armour wires.8. Pass the bedding through the gland body.9. Engage sleeve thread onto body thread and tighten securely.

    GN164GN204GN206GN254GN256GN324GN326GN405GN503GN505GN636GN753GN755

    M16 x 1.5 M20 x 1.5M20 x 1.5M25 x 1.5M25 x 1.5M32 x 1.5M32 x 1.5M40 x 1.5M50 x 1.5M50 x 1.5M63 x 1.52.5BSP2.5BSP

    10.0010.0010.0010.0010.0010.0010.0015.0015.0015.0019.0019.0019.00

    7.2011.0013.7516.2518.7522.7526.5032.7538.5044.4556.2560.3566.70

    10.8017.0020.0022.5026.0030.0034.0041.5049.0055.5068.2573.0079.40

    0.90 - 1.250.90 - 1.250.90 - 1.250.90 - 1.251.25 - 1.601.25 - 1.601.60 - 2.001.60 - 2.002.00 - 2.502.00 - 2.502.50 - 3.152.50 - 3.152.50 - 3.15

    20.525.227.530.333.639.544.554.260.366.782.695.3101.6

    21.526.326.326.335.738.738.744.651.354.556.060.060.0

    7.4010.4016.6019.6022.1025.6029.6033.6041.1048.6055.1067.8572.60

    8.08.08.08.010.512.012.014.015.515.517.521.521.5

    30202016864644211

    PROTRUSION

    CABL

    E OV

    ERAL

    LM

    AX

    ACRO

    SS C

    ORN

    ERS

    MOUN

    TING

    THRE

    AD

    CABL

    EO/B

    EDDI

    NG

    MAX

    BODYSWA

    EXPOSED CLAMP SLEEVE

    THREADLENGTH

    Product specifications may change at any time without notice.

    Part Mounting Thread Cable Acceptance Details Cable Gland Inner Number Size Length O/bedding Overall Diameter SWA Across SWA Carton (mm) (mm) Max. Min. Max. Dia. Corners Protrusion Exposed Pack (mm) (mm) (mm) (mm) (mm) (mm) (mm) Qty.

    GN Cable GlandGENERAL PURPOSE CABLE GLAND FOR STEEL WIRED ARMOURED CABLE

    5

  • ApplicationsIndoor and outdoor use

    FunctionProvides armour clamp, and sealon outer sheath

    Protection ClassIngress of waterIP66/68

    ConstructionNickel Plated Brass Components

    Part Mounting Thread Cable Acceptance Details Cable Gland Inner Number Size Length O/bedding Overall Diameter SWA Across SWA Carton (mm) (mm) Max. Min. Max. Dia. Corner Protrusion Exposed Pack (mm) (mm) (mm) (mm) (mm) (mm) (mm) Qty.

    MOUN

    TING

    THRE

    AD

    CABL

    EO/B

    EDDI

    NG

    MAX

    CABL

    E OV

    ERAL

    LM

    AX

    PROTRUSION

    BODY

    IP66/68 GASKETO RINGSEAL CLAMP

    SWAEXPOSED

    SLEEVE

    NEOPRENE SEAL

    NUT

    ACRO

    SS C

    ORN

    ERS

    THREADLENGTH

    WGN162WGN164WGN202WGN203WGN204WGN206WGN254WGN256WGN324WGN326WGN403WGN404WGN405WGN502WGN503WGN504WGN505WGN634WGN635WGN636WGN753WGN754WGN755WGN10AWGN10B

    M16 x 1.5M16 x 1.5M20 x 1.5M20 x 1.5M20 x 1.5M20 x 1.5M25 x 1.5M25 x 1.5M32 x 1.5M32 x 1.5M40 x 1.5M40 x 1.5M40 x 1.5M50 x 1.5M50 x 1.5M50 x 1.5M50 x 1.5M63 x 1.5M63 x 1.5M63 x 1.52.5BSP2.5BSP2.5BSP3BSP3BSP

    14141414141414141414151515151515151919191919191919

    6.007.208.009.7511.0013.7516.2518.7522.7526.5028.5030.7532.7535.7538.5041.6544.4548.8052.4056.2560.3563.5066.7070.0076.00

    9.6010.8012.0015.5017.0020.0022.5026.0030.0034.0037.0039.5041.5045.0049.0053.5055.5060.3563.5068.2573.0076.2079.4084.0088.50

    0.50 - 0.90 0.50 - 0.90 0.50 - 0.90 0.90 - 1.250.90 - 1.250.90 - 1.250.90 - 1.251.25 - 1.601.25 - 1.601.60 - 2.001.60 - 2.001.60 - 2.001.60 - 2.002.00 - 2.502.00 - 2.502.00 - 2.502.00 - 2.502.50 - 3.152.50 - 3.152.50 - 3.152.50 - 3.152.50 - 3.152.50 - 3.15

    3.153.15

    36 364040404040475555595959737373737979799393939090

    8899999111212131313141414141515152222222222

    4040303030208688444442211111111

    Fitting Instructions1. To comply with IP66/68 approvals, the fibre gasket must be installed on the mounting thread.2. Screw the gland body into the apparatus.3. Pass the gland nut, outer seal and gland sleeve over the cable before commencing to strip the outer sheath of the cable.4. Measure the length of tails required and add about 75 mm to the outer sheath and armour to this point.5. Strip the outer sheath.6. Cut the armour wire to SWA exposed length.7. Pass the armour clamp over the armour.8. Pass the body and armour cone over the bedding and under the armour wires.

    WGN10A - B Complete with earth fixing lug of 1/2 diameter.

    9. Engage sleeve thread onto body thread and tighten securely.10. Slide outer seal and gland nut into position and engage nut thread onto sleeve thread.11. Tighten gland nut securely.

    8.009.2010.4011.6015.1016.6019.6022.1025.6029.6033.6036.6039.1041.1044.6048.6053.1055.1059.9563.1067.8572.6075.8079.0083.60

    24.124.125.327.527.533.036.440.749.849.860.960.960.976.076.086.586.5101.9101.9101.9115.6115.6115.6124.0124.0

    Product specifications may change at any time without notice.

    WGN Cable GlandGENERAL PURPOSE CABLE GLAND FOR STEEL WIRED ARMOURED CABLE

    6

  • INNER NEOPRENESEAL

    SWAEXPOSED

    BODY

    IP66/68 GASKETO RINGSEAL

    CLAMP

    CONESLEEVE

    NUTOUTER NEOPRENE SEAL

    PROTRUSION

    ACRO

    SS C

    ORN

    ERS

    MOUN

    TING

    THRE

    AD

    CABL

    E OV

    ERAL

    LM

    AX

    CABL

    EO/B

    EDDI

    NG

    MAX

    THREADLENGTH

    9. Pass the armour cone over the bedding and under the armour wires.10. Pass the bedding through the inner seal in the gland body. N.B. Unless this seal provides a push fit on the bedding the next size gland will be required. (The minimum dimension over the bedding is embossed on the sleeve of the gland for reference.) On glands over FLWN405 one or two seals are supplied with each gland, select the most suitable seal.11. Engage sleeve thread onto body thread and tighten securely.12. Slide outer seal and gland nut into position and engage nut thread onto sleeve thread.13. Tighten gland nut securely.

    ApplicationsIndoor and Outdoor use in hazardous areas

    StandardsIEC 60079 - 0:2004 IEC 60079 - 1:2007 IEC 61241 - 0:2004 IEC 61241 - 1:2004

    FunctionProvides O/Bledding Flameproof Seal, ArmourClamp and Seal on Outer Sheath

    Protection ClassANZEx 11.2001xIECEx SIM 11.0002XEx d I/IICIngress of waterIP66/68 (30m)

    ConstructionNickel Plated Brass Components

    Fitting Instructions1. To comply with IP66/68 approvals, the fibre gasket must be installed on the mounting thread.2. Screw the gland body into the apparatus.3. Leave the inner seal in the gland body.4. Pass the gland nut, outer seal and gland sleeve over the cable before commencing to strip the outer sheath of the cable.5. Measure the length of tails required and add about 75 mm to the outer sheath and armour to this point.6. Strip the outer sheath.7. Cut the armour wire to SWA exposed length.8. Pass the armour clamp over the armour.

    Product specifications may change at any time without notice.

    Part Mounting Thread Cable Acceptance Details Cable Gland Inner Number Size Length Overbedding Overall Diameter SWA Across SWA Carton (mm) (mm) Min. Max. Min. Max. Dia. Corners Protrusion Exposed Pack (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) Qty.

    FLWN202 M20 x 1.5 15.80 6.00 8.00 11.00 13.00 0.50 - 0.90 25 54 12 30FLWN203 M20 x 1.5 15.80 8.30 9.75 12.50 15.50 0.90 - 1.25 27 54 12 30FLWN204 M20 x 1.5 15.80 9.35 11.00 15.10 17.00 0.90 - 1.25 27 54 12 30FLWN205 M20 x 1.5 15.80 10.60 12.50 16.60 20.00 0.90 - 1.25 33 54 12 20FLWN206 M20 x 1.5 15.80 12.00 13.75 17.00 20.00 0.90 - 1.25 33 54 12 20FLWN253 M25 x 1.5 19.00 13.35 15.00 19.60 22.50 0.90 - 1.25 36 56 12 14FLWN254 M25 x 1.5 19.00 14.60 16.25 19.60 22.50 0.90 - 1.25 36 56 12 14FLWN255 M25 x 1.5 19.00 15.85 17.50 22.10 26.00 1.25 - 1.60 41 56 12 12FLWN256 M25 x 1.5 19.00 17.10 18.75 23.00 26.00 1.25 - 1.60 41 56 12 12FLWN323 M32 x 1.5 25.40 18.35 20.75 25.60 30.00 1.25 - 1.60 50 64 13 8FLWN324 M32 x 1.5 25.40 20.35 22.75 25.60 30.00 1.25 - 1.60 50 64 13 8FLWN325 M32 x 1.5 25.40 22.35 24.75 29.60 34.00 1.60 - 2.00 50 64 13 8FLWN326 M32 x 1.5 25.40 24.35 26.50 30.00 34.00 1.60 - 2.00 50 64 13 8FLWN403 M40 x 1.5 25.40 26.10 28.50 33.60 37.00 1.60 - 2.00 61 72 15 1FLWN404 M40 x 1.5 25.40 28.10 30.75 36.60 39.50 1.60 - 2.00 61 72 15 1FLWN405 M40 x 1.5 25.40 30.35 32.75 37.00 41.50 1.60 - 2.00 61 72 15 1

    FLWN Cable GlandFLAMEPROOF CABLE GLAND FOR STEEL WIRE ARMOURED CABLE

    7

  • Part Mounting Thread Cable Acceptance Details Cable Gland Inner Number Size Length O/bedding Overall Diameter SWA Across SWA Carton (mm) (mm) Max. Min. Max. Dia. Corners Protrusion Exposed Pack (mm) (mm) (mm) (mm) (mm) (mm) (mm) Qty.

    Fitting Instructions1. To comply with IP66/68 approvals, the fibre gasket must be installed on the mounting thread.2. Pass Nut, Seal and Sleeve over the outer sheath of cable (Where more than 1 seal is supplied, use the seal with the smallest clearance on the cable).3. Measure the length of cores required and strip the outer sheath and armour wires to the length shown in Table 1.4. Remove the Bedding and any fillers to the length shown in Table 2.5. Slide the clamp over the armour wires and work the Cone over the bedding and under the SWA.6. Locate the Body onto the Cores and hold hard against the face of the Cone. Screw the Sleeve onto the Body and tighten, now tighten the nut onto the sleeve.7. Remove the Body from the assembly.8. Prepare the epoxy putty. This is a 2 part pack and must be mixed in a ratio of 1 to 1 until the colour is even throughout, without any streaks. After mixing it remains pliable for at least 1 hour. (see Useable Life for Mixed Epoxy below)

    Note: The Red Epoxy component is affected by storage temperature. Please check to ensure this component is as pliable as the yellow component. It is recommended that the epoxy should be mixed and fitted only with the user wearing the disposable gloves supplied with every gland.

    9. Spread the conductors and apply to epoxy to the EXPOSED CENTRE of the conductors. Close the conductors and pack putty into the recess of the cone and down onto the top of the bedding material leaving a shoulder of putty to fill the sleeve cup.

    ApplicationsIndoor and Outdoor use in hazardous areas

    StandardsIEC 60079 - 0:2004 IEC 60079 - 1:2007 IEC 61241 - 0:2004 IEC 61241 - 1:2004

    FunctionProvides Barrier Epoxy Seal to Cable Cores,Armour Clamp, and Seal on Outer Sheath

    Protection ClassANZEx 11.2001XIECEx SIM 11.0002X Ex d I//IICIngress of waterIP66/68 (30m)

    ConstructionNickel Plated Brass Components

    FLPW203BFLPW206BFLPW256BFLPW326BFLPW405BFLPW503BFLPW505BFLPW635BFLPW636BFLPW754BFLPW755B

    M20 x 1.5M20 x 1.5M25 x 1.5M32 x 1.5M40 x 1.5M50 x 1.5M50 x 1.5M63 x 1.5M63 x 1.5

    2.5BSP2.5BSP

    15.8015.8019.0025.4025.4028.6028.6028.6028.6028.6028.60

    9.7513.7518.7526.5032.7538.5044.4552.4056.2563.5066.70

    15.5020.0026.0034.0041.5049.0055.5063.5068.0076.0079.40

    0.90 - 1.25 0.90 - 1.251.25 - 1.601.60 - 2.001.60 - 2.002.00 - 2.502.00 - 2.502.50 - 3.152.50 - 3.152.50 - 3.152.50 - 3.15

    27334150617687102102116116

    545456647288889696100100

    12.5015.0019.5025.5033.5041.0048.5055.0063.0067.5075.50

    11.511.511.513.515.5171719192323

    14141062221111

    MOUN

    TING

    THRE

    AD

    CABL

    EO/B

    EDDI

    NG

    MAX

    EPOXY

    PROTRUSION

    CABL

    E OV

    ERAL

    LM

    AXAC

    ROSS

    CORN

    ERS

    CLAMPSWA

    EXPOSEDSLEEVE

    NUTOUTER NEOPRENE SEALCONEBODY SLEEVEO RING

    SEAL

    IP66/68 GASKETBODY

    THREADLENGTH

    Continue folding putty round the conductors and working it well in between them, joining with that extruded from the core center avoiding any gaps or voids. Cover the conductors from the face of the cone to the length equal at least to the length of the Sleeve.10. Assemble the Sleeve over the epoxy until it fits into the Cone. Remove any surplus epoxy.11. Reassemble the Body, tighten and allow at least three hours for the epoxy to reach correct hardness.12. Remove the Body, fit to the equipment the reassemble completed fitting.

    TABLE 1 TABLE 2Gland mm

    FLPW203BFLPW206BFLPW256BFLPW326BFLPW405BFLPW503BFLPW505BFLPW635BFLPW636BFLPW754BFLPW755B

    11.5011.5011.5013.5015.5017.0017.0019.0019.0023.0023.00

    Gland mmFLPW203BFLPW206BFLPW256BFLPW326BFLPW405BFLPW503BFLPW505BFLPW635BFLPW636BFLPW754BFLPW755B

    13.5013.5013.5015.5017.5017.5019.5021.0021.0025.0025.00

    Useable Life for Mixed EpoxyThis will depend upon the bulk mass and temperature. 25 grams wt 2 hours @ 25deg. CApproximate figures are: 25 grams wt 3 hours @ 15deg. C

    CureThis will depend upon the bulk mass and temperature. 25 grams wt 12 hours @ 25deg. CApproximate figures are: 25 grams wt 24 hours @ 15deg. C

    Mechanical properties of cured mixTensile strength BS6319 2 days min. 30MPaCompressive strength BS6319 2 days min. 40MPaHardness min 75 shore DSpecific Gravity @ 20 deg. C 1.84 to 1.99

    Product specifications may change at any time without notice.

    FLPWB Cable GlandBARRIER CABLE GLAND FOR STEEL WIRE ARMOURED CABLE

    8

  • Earth Tags

    E16E20E25E32E40E50E63

    M16M20M25M32M40M50M63

    TBA20010050502525

    6.356.356.356.356.356.356.35

    Locknuts

    Extension Nuts for UFPN Glands

    L12LNB-16LNB-20LNB-25LNB-32LNB-40LNB-50LNB-63

    L250L275L300L325L350L400

    1/2 X 26 TPIM16 x 1.5M20 x 1.5M25 x 1.5M32 x 1.5M40 x 1.5M50 x 1.5M63 x 1.52.5 BSP2.75 BSP3.0 BSP3.25 BSP3.5 BSP4.0 BSP

    100100100100100402520666664

    EN20AEN20BEN20CEN25AEN32AEN32B

    403739424547

    282831364246

    181410886

    Part Suits Cable Gland Inner Number Gland Across Carton Corners Protrusion Pack (mm) (mm) Quantity

    Orange Shrouds

    CUT

    LINE

    FOR

    MIN

    IMUM

    CAB

    LEDI

    AMET

    ER

    SHRO

    UDNUM

    BER

    TO S

    UIT

    GLAN

    DFR

    OM

    SEL

    ECTI

    ON

    CHAR

    T

    MOUN

    TING

    THRE

    AD

    DIAM

    ETER

    EART

    H B

    OLT

    DIAM

    ETER

    ACROSS FLATS

    MOUNTING THREAD

    CUT

    LINE

    FOR

    MIN

    IMUM

    CAB

    LEDI

    AMET

    ER

    SHRO

    UDNUM

    BER

    TO S

    UIT

    GLAN

    DFR

    OM

    SEL

    ECTI

    ON

    CHAR

    T

    MOUN

    TING

    THRE

    AD

    DIAM

    ETER

    EART

    H B

    OLT

    DIAM

    ETER

    ACROSS FLATS

    MOUNTING THREAD

    CUT LINE FORMINIMUM CABLE

    DIAMETER

    SHROUDNUMBER

    TO SUIT GLANDFROM SELECTION

    CHART

    MOUNTING THREAD

    DIAMETER

    EARTH BOLTDIAMETER

    ACROSS FLATS

    MOUN

    TING TH

    READ

    PROTRUSION

    EXTENSION NUT

    ACRO

    SS C

    ORN

    ERS

    FLPW203B

    FLPW206B

    FLPW256B

    FLPW326B

    FLPW405B

    FLPW503B

    FLWN202FLWN203FLWN204FLWN205FLWN206FLWN253FLWN254FLWN255FLWN256FLWN323FLWN324FLWN325FLWN326FLWN403FLWN404FLWN405FLWN502FLWN503

    WGN162WGN164WGN202WGN203WGN204

    WGN206WGN254WGN256

    WGN324WGN326

    WGN403WGN404WGN405WGN502WGN503

    S0-Orange

    S1-Orange

    S2-Orange

    S3-Orange

    S4-Orange

    S5-Orange

    S6-Orange

    S7-Orange

    UN20AUN20B

    UN25A

    UN32A

    UN40A

    UN40BUN50A

    UN50BUN63A

    UN63B

    UFPN20AUFPN20B

    UFPN20C

    UFPN25A

    UFPN32A

    UFPN32B

    UFPN40AUFPN40B

    UFPN50AUFPN50B

    UFPN63AUFPN63B

    GN204GN206GN254GN256

    GN324GN326

    GN405

    GN503GN505

    GN636

    Part Mounting Earth Inner Number Thread Bolt Carton Diameter Pack (mm) Quantity

    Part Mounting Across Inner Number Thread Flats Carton Hexagon Pack (mm) Quantity

    1620.727

    31.640

    48.257.38294102116116124140

    150

    140

    110

    90

    70

    50

    40

    18

    Part Cable Gland Number UN UFPN GN WGN FLWN FLPWB Carton Pack Quantity

    UFPN20AUFPN20BUFPN20CUFPN25AUFPN32AUFPN32B

    Cable Gland Accessories

    9

  • UB4PUB8P

    UB13P

    UB17PUB22P

    UB27P

    UB31P

    UB36PUB41P

    UB45P

    UB117P

    UB118PUB119P

    UB517P

    UB518P

    WGN162WGN164WGN202WGN203WGN204WGN206

    WGN254WGN256

    WGN324WGN326

    WGN403WGN404WGN405

    WGN502WGN503WGN504WGN505WGN634WGN635WGN636

    WGN753WGN754WGN755

    WGN10AWGN10B

    1/2M16

    M20

    M20M25

    M32

    M40

    M50M50

    M63

    2.5 BSP

    2.75 BSP3 BSP

    3.5 BSP

    4 BSP

    UN12AUN16A

    UN20A

    UN20BUN25A

    UN32A

    UN40AUN40B

    UN50AUN50B

    UN63AUN63B

    FLWN202FLWN203FLWN204FLWN205FLWN206

    FLWN253FLWN254FLWN255FLWN256FLWN323FLWN324FLWN325FLWN326FLWN403FLWN404FLWN405

    FLWN502FLWN503FLWN504FLWN505FLWN633FLWN634FLWN635FLWN636FLWN753FLWN754FLWN755

    UFPN20AUFPN20BUFPN20C

    UFPN25A

    UFPN32AUFPN32B

    UFPN40AUFPN40B

    UFPN50AUFPN50B

    UFPN63AUFPN63B

    UFPN250A

    UFPN275AUFPN300A

    UFPN350AUFPN350BUFPN400AUFPN400B

    FLPW203BFLPW206B

    FLPW256B

    FLPW326B

    FLPW405B

    FLPW503BFLPW505B

    FLPW635BFLPW636B

    FLPW754BFLPW755B

    100100

    100

    100100

    100

    100

    100100

    20

    20

    2020

    20

    20

    IP66/68 GASKETAs supplied with glands

    Fibre Gasket

    Part Mounting Cable Gland Number Thread UN UFPN WGN FLWN FLPWB Carton Size Pack Quantity

    Nicote Accessories

    10

  • ApplicationsIndoor and outdoor use in harsh environments

    StandardsAS60529-2004

    FunctionProvides seal on cable sheath

    Protection ClassIP65

    ConstructionBody and compression nut304 Stainless Steel

    SSG Cable GlandGENERAL PURPOSE STAINLESS STEEL CABLE GLANDS

    Stainless Steel Cable Glands are high quality glands designed for use in severe environments. Made from 304 grade stainless steel, each gland features a wide cable diameter range and UP65 protection.

    8.411.516.321

    27.7

    3.56.4111519

    M16x1.5M20x1.5M20x1.5M25x1.5M32x1.5

    Part Mounting Cable Acceptance Number Thread Details Across Pack Size Length Overall Diameter Corners Qty (mm) (mm) Min (mm) Max (mm) (mm)

    SSG-16-8SSG-20-11SSG-20-16

    SSG-25SSG-32

    1010121212

    5025252510

    2222

    27.53240

    MOUN

    TING

    THRE

    AD

    ACRO

    SS C

    ORN

    ERS

    CABL

    E OV

    ERAL

    L

    MAX

    BODY

    SEAL

    SKID WASHER

    NUT

    PROTRUSIONTHREADLENGTH

    Pro

    duct

    spe

    cific

    atio

    ns m

    ay c

    hang

    eat

    any

    tim

    e w

    ithou

    t not

    ice.

    11

  • For further information, contact Thomas & Betts National Support Centre onPhone 1300 666 595 Fax 1300 666 594 Email [email protected] Website www.tnbaust.comThomas & Betts Australasia Pty Ltd Head Office,

    Suite 3, Level 7, 3 Rider Boulevard, Rhodes NSW 2138 Australia ABN 62 074 810 898