n=&%ge · pdf filematrix gfx-m stainless steel floor mount, with gloss silver mantel...

4
External dimensions for all GFX Matrix Gas Log Fires (All dimensions in millimeters) Matrix MODEL A B1 & B2 C D E F G H I GFX-S 945 B1=875 / B2=795 740 520 530 80 650 285 903 GFX-M 1045 B1=960 / B2=880 830 520 612 80 750 285 1003 GFX-L 1140 B1=1045 / B2=972 920 520 701 80 850 285 1099 Suggested wall cut out sizes. (Suits Standard fascia & larger) IMPORTANT: Allow min. 150mm up from floor when fitting standard window fascia and extra if skirting is fitted to the wall. Matrix MODEL HEIGHT (A1) MIN WIDTH (B1) MIN DEPTH (C1) MIN GFX-S 780m 920mm 550mm GFX-M 865mm 1020mm 550mm GFX-L 950mm 1120mm 550mm B1 A WALL MOUNT FASCIA MODEL GAS TYPE MJH INJECTOR SIZE KW Rating Vertical KW Rating Horizontal Matrix GFX-S NAT 28 2.5 5.64 5.71 Matrix GFX-M NAT 34 2.7 7.14 6.86 Matrix GFX-L NAT 40 3.0 8.14 7.87 ELECTRICAL COMPONENTS CONFORM TO AS 3100 240V 50HZ 60 WATTS SIDE VIEW REAR MOUNTED FLUE E I G H TOP VIEW TOP FLUE D SIDE VIEW TOP MOUNTED FLUE C F (WALL MOUNT FASCIA) A B2 FLOOR WALL MOUNT FASCIA NOTE: The minimum width, depth and height shown in the table below relate to standard floor mounted fascia dimensions. A more detailed dimension sheet is available from your dealer. A1 C1 Minimum Width B1 Note: All flue pipes including active inner & any outer cases must be installed with the crimped end of the pipe facing up Plaster or similar faced wall with timber framing 8” (205mm) Outer Case 6” (152mm) Active Flue Recommended minimum distance from top of heater to underside of timber frame is 70mm provided that the gap between any active flue pipe and any timber or combustible material is a minimum of 25mm, or the gap between any outer case and any timber or combustible material is a minimum of 10mm. Weatherproof Housing Angle Bracket 500mm Minimum Dektite Flashing (Supplied by Installer) Illusion Australia Pty Ltd (ABN 35 005 834 784) 145 South Gippsland Highway, Dandenong Victoria 3175 Phone: (03) 9793 7520 Fax: (03) 9791 7162 (PDLO VDOHV#LOOXVLRQÀUHVFRPDX :HE ZZZLOOXVLRQÀUHVFRPDX Copyright © Illusion Australia Pty Ltd 2104

Upload: truongquynh

Post on 26-Mar-2018

214 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: N=&%GE · PDF fileMatrix GFX-M Stainless Steel Floor Mount, with Gloss Silver Mantel 0DWUL[ *); 0 6WDLQOHVV 6WHHO &KDUFRDO Floor Mount, with Gloss Black Mantel

External dimensions for all GFX Matrix Gas Log Fires (All dimensions in millimeters)

Matrix MODEL A B1 & B2 C D E F G H I

GFX-S 945 B1=875 / B2=795 740 520 530 80 650 285 903

GFX-M 1045 B1=960 / B2=880 830 520 612 80 750 285 1003

GFX-L 1140 B1=1045 / B2=972 920 520 701 80 850 285 1099

Suggested wall cut out sizes. (Suits Standard fascia & larger)IMPORTANT: Allow min. 150mm up from floor when fitting standard window fascia and extra if skirting is fitted to the wall.

Matrix MODEL HEIGHT (A1) MIN WIDTH (B1) MIN DEPTH (C1) MIN

GFX-S 780m 920mm 550mm

GFX-M 865mm 1020mm 550mm

GFX-L 950mm 1120mm 550mm

B1

AWALL MOUNT FASCIA

MODEL GAS TYPE MJH INJECTOR SIZE KW Rating Vertical KW Rating Horizontal

Matrix GFX-S NAT 28 2.5 5.64 5.71

Matrix GFX-M NAT 34 2.7 7.14 6.86

Matrix GFX-L NAT 40 3.0 8.14 7.87

ELECTRICAL COMPONENTS CONFORM TO AS 3100 240V 50HZ 60 WATTS

SIDE VIEW REAR MOUNTED FLUE

E

I

G

H

TOP VIEW

TOP FLUE

D

SIDE VIEW TOP MOUNTED FLUE C

F (WALL MOUNT FASCIA)

A

B2

FLOOR WALL MOUNT FASCIA

NOTE: The minimum width, depth and height shown in the table below relate to standard floor mounted fascia dimensions. A more detailed dimension sheet is available from your dealer.

A1

C1

MinimumWidth

B1

Note: All flue pipesincluding active inner& any outer casesmust be installed withthe crimped end ofthe pipe facing up

Plaster or similarfaced wall withtimber framing

8” (205mm)Outer Case

6” (152mm)Active Flue

Recommended minimumdistance from top of heaterto underside of timber frame is 70mm provided that the gap between any active flue pipe and any timber or combustible material is a minimum of 25mm, or the gap between any outer case and any timber or combustible material is a minimum of 10mm.

WeatherproofHousing

Angle Bracket

500mmMinimum

Dektite Flashing(Supplied by Installer)

Illusion Australia Pty Ltd (ABN 35 005 834 784) 145 South Gippsland Highway, Dandenong Victoria 3175Phone: (03) 9793 7520 Fax: (03) 9791 7162

(PDLO��VDOHV#LOOXVLRQÀUHV�FRP�DX���:HE��ZZZ�LOOXVLRQÀUHV�FRP�DXCopyright © Illusion Australia Pty Ltd 2104

Page 2: N=&%GE · PDF fileMatrix GFX-M Stainless Steel Floor Mount, with Gloss Silver Mantel 0DWUL[ *); 0 6WDLQOHVV 6WHHO &KDUFRDO Floor Mount, with Gloss Black Mantel

F u n c t i o n

The Illusion Matrix Series of Gas Log Fires DUH�DYDLODEOH�LQ���GLVWLQFW�VL]HV�LQFOXGLQJ�the compact GFX-S, midrange GFX-M and the Spectacular GFX-L making VHOHFWLRQ�RI�D�VXLWDEO\�VL]HG�XQLW�D�EUHH]H��

F o r m

S t y l e

V e r s a t i l i t y

:LWK�D�ÀUHER[�GHVLJQHG�WR�PD[LPLVH�visual appeal, auto fan on function, +L���/R�ÁDPH�FRQWURO�DQG�RSWLRQDO�UHPRWH�operation the Illusion Matrix Gas Log Fire SXWV�WKH�FRQWURO�LQ�\RXU�KDQGV���

Visually stunning, with logs moulded directly off Australian hardwood you ZRQ·W�ÀQG�D�PRUH�UHDOLVWLF��JDV�ORJ�ÀUH�DQ\ZKHUH��(DFK�ORJ�LV�PHWLFXORXVO\�KDQG�SDLQWHG�E\�FUDIWVPHQ�ZKR�WDNH�SULGH�LQ�WKHLU�ZRUN��<RX·OO�EH�KDUG�SUHVVHG�WR�SLFN�our logs from the real thing!

)XOO\�WHVWHG�DQG�DSSURYHG�E\�WKH�$*$�to Australian Standards, the Illusion Matrix 6HULHV�FDQ�EH�LQVWDOOHG�WKURXJK�PRVW�ZDOOV��LQWR�SXUSRVH�EXLOW�FDYLWLHV�RU�HYHQ�LQ�DQ�$O�)UHVFR�RXWGRRU�ÀUHSODFH��7KH�SRVVLELOLWLHV�DUH�HQGOHVV�DQG�OLPLWHG�RQO\�E\�\RXU�LPDJLQDWLRQ��

M a t r i xS e r i e s

Choose from a multitude of designercolours and fascia Styles

Gas Log FiresILLusion

:DOO�PRXQWHG��QR�FKLPQH\�QHFHVVDU\

Through wall with mantel and extended fascia

B a l a n c e d F l u e

7KH�,OOXVLRQ�0DWUL[�6HULHV�FDQ�EH�LQVWDOOHG�with either a rear mounted or top PRXQWHG�ÁXH�V\VWHP�

I n s t a l l a t i o n

� � � < H D U � : D U U D Q W \

)RU�\RXU��VDIHW\��WKH�FRPEXVWLRQ�DLU�IRU�WKH�ÀUH�LV�GUDZQ�IURP��RXU�EDODQFHG�ÁXH�V\VWHP���8VLQJ�QDWXUDO�FRQYHFWLRQ�E\�GUDZLQJ�DLU�IURP�RXWVLGH�WKH�EXLOGLQJ��LW�SURYLGHV�ÁH[LEOH�DQG�FRPIRUWDEOH�ZDUPWK�$�QRQ�EDODQFHG�ÁXH�UHTXLUHV�FRQVWDQW�YHQWLODWLRQ�WR�NHHS�LW�EXUQLQJ�DQG�FDQ�PDNH�WKH�URRP�VWXII\��,Q�FRQWUDVW��D�EDODQFHG�ÁXH�JDV�ÀUH�LV�URRP�VHDOHG�XVLQJ�D�JODVV�IURQW��,W�KDV�D�VRSKLVWLFDWHG�ÁXH�WKDW�XVHV�QDWXUDO�convection to draw the air from outside WKH�EXLOGLQJ�IRU�FRPEXVWLRQ�DQG�H[SHOV�LW�EDFN�WR�WKH�RXWVLGH�WKURXJK�D�VHSDUDWH�FRPSDUWPHQW�RI�WKH�ÁXH���

The Illusion Matrix Series of Gas Log Fires come with a ten year warranty on WKH�ÀUHER[���$OO�RWKHU�FRPSRQHQWV�DUH�warranted for 12 months from the date of SXUFKDVH���

Gas Log FiresILLusion

A u s t r a l i a n M a d eILLusion Gas Log Fires are designed and PDGH�LQ�$XVWUDOLD�DQG�XWLOLVH�WKH�ÀQHVW�DYDLODEOH�PDWHULDOV�DQG�SURFHVVHV�WR�SURGXFH�D�XQLTXHO\�$XVWUDOLDQ�SURGXFW��1R�RWKHU�ORFDOO\�PDGH�JDV�ORJ�ÀUH�FDQ�compare to an ILLusion Matrix Series Gas /RJ�)LUH�

,OOXVLRQ�2SHQ�*DV�/RJ�)LUHV�3W\��/WG��LV�D�wholly Australian owned and operated &RPSDQ\��$OO�,//XVLRQ�JDV�ORJ�ÀUHV�DUH�manufactured in Australia to exacting VWDQGDUGV��

Floor Mount Stainless Steel

:DOO�0RXQW��6WDLQOHVV��&KDUFRDO

:DOO�0RXQW�6WDLQOHVV�6WHHO :DOO�0RXQW��&KDUFRDO

)ORRU�0RXQW��6WDLQOHVV��&KDUFRDO

Floor Mount Stainless Steel with extended fascia

:DOO�0RXQW�5DZ�&RWWRQ��6WDLQOHVV

Page 3: N=&%GE · PDF fileMatrix GFX-M Stainless Steel Floor Mount, with Gloss Silver Mantel 0DWUL[ *); 0 6WDLQOHVV 6WHHO &KDUFRDO Floor Mount, with Gloss Black Mantel

The Matrix Series will change yourYLHZV�RQ�*DV�/RJ�)LUHV�IRUHYHU�

:LWK�WKH�PRVW�OLIH�OLNH�ORJV�DYDLODEOH�DQ\ZKHUH�LQ�WKH�ZRUOG���Matrix attains a level of realism RWKHUV�FDQ�RQO\�DVSLUH�WR�

Stylish fascias set the trend framing an enormous ceramic JODVV�YLHZLQJ�DUHD� Enjoy your free time without the hassles , mess, or fuss involved in FROOHFWLQJ�DQG�VWRULQJ�ÀUHZRRG�

5 H D O L V P

The Matrix Series lends itself perfectly to outdoor LQVWDOODWLRQV�SURYLGLQJ�D�FRV\�DPELHQFH�WR�\RXU�RXWGRRU�HQWHUWDLQPHQW�DUHD�

E n t e r t a i n

F a s h i o n

%ULQJ�LQ�\RXU�SODQV�DQG�OHW�XV�PDNH�\RXU�LGHDV�D�UHDOLW\��2XU�VWDII�ZLOO�ZRUN�FORVHO\�ZLWK�\RX�WR�HQVXUH�WKH�HQG�UHVXOW�LV�DOO�\RX�H[SHFW�DQG�PRUH�� 1RQ�VWDQGDUG�)DVFLDV�FDQ�EH�PDQXIDFWXUHG�IRU�DGGLWLRQDO�FRVW��

F u n c t i o n

C h o i c e0DWUL[�RIIHUV�\RX�D�UDQJH�RI�VL]HV��FRORXUV�DQG�WULP�RSWLRQV�VR�\RX�FDQ�EH�DVVXUHG�\RXU�FKRLFH�LV�WKH�ULJKW�RQH�

Our experts can arrange a home inspection at your convenience and will advise on installation and regulatory UHTXLUHPHQWV��

And you can relax with the knowledge WKDW�HYHU\�,OOXVLRQ�JDV�ORJ�ÀUH�KDV�EHHQ�WHVWHG�DQG�DSSURYHG�E\�WKH�$XVWUDOLDQ�*DV�$VVRFLDWLRQ�WR�$XVWUDOLDQ�6WDQGDUGV�

<RX�GRQ·W�QHHG�D�PDVRQDU\�FKLPQH\�WR�LQVWDOO�D�0DWUL[�*DV�/RJ�)LUH���0RGHUQ��7UDGLWLRQDO��&RQWHPSRUDU\�GHVLJQV��WKH�SRVVLELOLWLHV�DUH�HQGOHVV�ZLWK

an ILLusion Matrix Series Gas Log Fire!

2SWLRQDO�3URJUDPPDEOH�7KHUPRVWDWLF�)0�5HPRWH�&RQWURO

8 Q O H D V K � \ R X U � L P D J L Q D W L R Q 8 Q O H D V K � \ R X U � L P D J L Q D W L R Q

Page 4: N=&%GE · PDF fileMatrix GFX-M Stainless Steel Floor Mount, with Gloss Silver Mantel 0DWUL[ *); 0 6WDLQOHVV 6WHHO &KDUFRDO Floor Mount, with Gloss Black Mantel

Matrix GFX-M Stainless Steel Floor Mount, with Gloss Silver Mantel

0DWUL[�*);�0�6WDLQOHVV�6WHHO���&KDUFRDO�Floor Mount, with Gloss Black Mantel

�0DWUL[�*);�6�5DZ�&RWWRQ�)ORRU�0RXQW��ZLWK�*ORVV�:KLWH�0DQWHO

0DWUL[�*);�0�6WDLQOHVV��&KDUFRDO�)ORRU�0RXQW��ZLWK�*ORVV�:KLWH�0DQWHO 8 Q O H D V K � \ R X U � L P D J L Q D W L R Q

M a t r i x

0DWUL[�*);�0�6WDLQOHVV�6WHHO��&KDUFRDO�)ORRU�0RXQW��ZLWK�WLOHV�DQG�PDQWHO�

0DWUL[�*);�/�6WDLQOHVV�6WHHO��:DOO�0RXQW��RQ�WLOHV�ZLWK��%ODFN�0DQWHO�

�0DWUL[�*);�0�LQ�0RFFKD�:DOO�0RXQW��RQ�WXPEOHG�EULFN�ZDOO�

0DWUL[�*);�0�6WDLQOHVV�6WHHO�:DOO�0RXQW��RQ�VWRQH�ÀUHSODFH