newtown public school hall top view

Upload: john-gaspar

Post on 08-Mar-2016

212 views

Category:

Documents


0 download

DESCRIPTION

1989

TRANSCRIPT

  • 543210m

    1:100 @ A1, 1:200 @ A3

    1:100

    REFLECTED CEILING PLAN 0104 C

    B 23.09.09 FOR CONSTRUCTION-SERVICES CO-ORDINATION

    C

    C 23.12.09

    C

    COLA ROOF DELETED, AWNING AND WHD ADDED

    C

    REV DATE AMENDMENT BY

    AMENDMENTS

    DRAFTED DATE

    DET SCHOOL I.D NUMBER DISCIPLINE CODE

    DRAWING NUMBER REVISION

    NUMBERSERIES

    NUMBERBUILDING

    NORTHPROJECT

    DET

    AND TRAININGOF EDUCATION DEPARTMENT

    SORTA RECEN QUAM PU

    RA N SETI

    NO

    RT

    H

    SCALES ( A1 original )

    BUILDING EDUCATION REVOLUTIONCONTRACTOR:ARCHITECT:

    0

    924 PACIFIC HIGHWAY GORDON NSW 2072

    Use figured Dimensions.of components. Do not scale drawings.any work, makingof shop drawings or fabrication

    on site prior to the commencement ofverified All levels and dimensions are to be checked and

    permission of Abigroup .writtenin part or in whole without the

    form or by any meanstransmitted in anymaynot be altered,reproduced orand

    This drawing is the copyright of ABIgroup

    REV DATE AMENDMENT BY

    AMENDMENTS

    -Aarchitecture interior design urban design planning nom architect M. Sheldon 3990

    Australia 2011 www.groupgsa.com T +612 9361 4144 F +612 9332 3458 Group GSA Pty Ltd ABN 76 002 113 779 Level 7, 80 William St East Sydney NSW

    KEYNOTE LEGEND

    BOLLARDBALUSTRADEBUILDING UNDER

    CIRCULAR CONCRETE COLUMN

    CEILING DIFFUSER VENTSKYLIGHT DIFFUSER PANELCEILING FANFIBRE CEMENT CEILINGWATER RESISTANT F/C CEILING

    COVERED OUTDOOR LEARNING AREA

    PLASTERBOARD CEILING

    GRATED DRAIN

    CARPETSTEEL TROWEL CONCRETECERAMIC FLOOR TILESFIXED GLAZINGFIXED OBSCURE GLAZINGTIMBER BOARD FLOORINGVINYL SHEETING FOAM BACKEDVINYL SHEETING

    FIXED METAL LOUVREADJUSTABLE METAL LOUVRELUMINAIREMECH VENTILATION EXHAUST COWLMECH VENTILATION DUCTMECH VENTILATION REGISTERPERFORATED METAL

    PHOTOVOLTAIC CELLBARGE ROLLROOF OVERRIDGE CAPPINGROOF FLASHINGCORRUGATED METAL ROOF SHEETING

    ROTARY ROOF VENTILATORVENTILATED SKYLIGHTRAINWATER GUTTERRAINWATER DOWN PIPESTEEL COLUMN

    SKIRTINGDUCTED SKIRTINGSUNHOOD

    TIMBER POSTTERRAZZO PARTITION

    FACE BRICKWORK

    CERAMIC WALL TILES

    WALL FANPERFORATED FIBRE CEMENT PANELS

    WEATHER HOODPERFORATED PLYWOOD LINING

    PLYWOOD WALL LININGPINBOARD WALL LININGPERFORATED PLASTERBOARD WALL LININGPERFORATED METAL WALL SHEETING HORIZONTAL CORRUGATIONS

    CORRUGATIONS

    CORRUGATIONSWATER TANK

    ALP

    BBALBU

    CCCCDTCDVCDYCFCFSCFWCMA

    CMSCOLA

    CPBCPP

    DGR

    FCPFCSFCTFGFGOFTBFVFFVS

    LMFLMALUMMVEMVDMVRPM

    PVCRBRRORRCRSFRSMRSTRVRVSRWGRWPSC

    SKSKDSNH

    TPTPN

    WBF

    WCT

    WFWFA

    WHDWPAWPB

    WPLWPNWPPWSA

    WSH

    WSV

    WT

    AP ACCESS PANELASV ANTI STATIC VINYL

    CBR CURTAIN BAR

    CMM CEILING MOUNTED MICROPHONE

    CP CONCRETE PAVINGCPF

    PERFORATED P.B. CEILING & NOISE BARRIER

    DTO DOUBLE TELECOMM OUTLET

    TGSI

    FW FLOOR WASTE

    ISF INDUSTRIAL SHEET FLOORINGIWB INTERACTIVE WHITE BOARD

    SD SMOKE DETECTOR

    ST SOAKER TRAYTD TUNDISH

    VP VENT PIPE

    WD WASTE DRAIN

    FIBRE CEMENT WALL SHEETINGWFS

    WPF

    WEJ WALL EXPANSION JOINT

    WBS TWO COURSES HIGH SOLDIER CANT BRICK WBR RENDERED BRICKWORK WALL

    PT PAINTED FINISH

    DBLK

    1 2 3 4 5 6 7 8 9 10M

    HANDRAILHRHWU HOT WATER UNIT

    TACTILE GROUND SURFACE INDICATORS

    ALUMINIUM COMPOSITE PANEL

    PLASTERBOARD WALL LINING PLASTERBOARD WALL LINING - FIRE-RATED

    DESIGNER BLOCK

    SNS SUN SHADING

    7431_A_B_0104.dgn 24/12/2009 1:42:37 PM

    WFC COMPRESSED FIBRE CEMENT WALL SHEETING

    METAL WALL SHEETING - HORIZONTAL

    METAL WALL SHEETING - VERTICAL

    CORRUGATED TRANSLUCENT ROOF SHEETING

    CORRUGATED METAL SOFFIT - TYPE 1

    CORRUGATED METAL SOFFIT - TYPE 2

    PLASTERBOARD CEILING - FIRE-RATED

    TRANSLUCENT CEILING DIFFUSER

    7431

    1 24.06.09 80% - TENDER - FOR REVIEW

    10.06.09HHNEWTOWN NSW 2042NORFOLK STREET

    7431 NEWTOWN PUBLIC SCHOOL2 24.07.09 100% - ISSUED TO QS FOR COSTING3 05.08.09 REVISED 100% ISSUE FOR COSTINGA 11.09.09 FOR CONSTRUCTION

    CC

    BB

    2

    2

    4

    4

    5

    5

    6

    6

    D D

    AA

    3

    3

    EE

    7

    71

    1

    CL 2800

    ABO

    VE

    SKYLIG

    HT

    CFS

    G.11

    ABO

    VE

    SKYLIG

    HT

    ABO

    VE

    SKYLIG

    HT

    2400

    A/L

    HYD. SERV.

    CMSCMSCMSCMS

    CMS

    CPP

    CPB

    CPP

    CMA

    CMS

    CMSCMS

    CPB

    CPB

    CPB

    CPB

    CPB

    CPB

    CPP

    CPP

    RA

    KE

    D C

    EILIN

    GR

    AK

    ED C

    EILIN

    G

    WHD

    CPB

    EQEQ EQEQ EQEQ EQEQ

    EQ

    EQ

    1500

    2928EQEQEQEQ2927

    1400

    1500

    EQ

    EQ

    1500

    2400

    4290 EQ EQ 4290

    4290EQEQ4290

    CL 2800

    CFS

    G.03

    STORECHAIR

    LUM

    LUM

    CL 2800

    CFS

    G.04

    STOREPERFORMANCE

    LUM

    LUM

    CL 2800

    CFS

    G.05

    P.E STORE

    LU

    ML

    UM

    LU

    ML

    UM

    1165116510651065

    CL 2800

    CFS

    G.06

    A/L

    LU

    M

    175

    LU

    M

    LU

    M

    370

    200

    EQ EQ535 735EQ EQEQ EQEQ EQEQ EQ

    CL 2800

    CFSG.08

    LUM

    SOUND CBD

    5351460800 800

    CFW

    G.13

    CL 2800

    ACCESS

    930

    635

    LIGHTHEATER/EXHAUST

    SENSORMOTION

    LU

    M

    CL 2800

    CFS

    G.10

    LU

    M

    175

    LU

    M

    EQ

    EQ

    CL 2800

    CFS

    G.14

    MSBCL 2800

    CFS

    G.12

    CDS

    LUM

    LUM

    295

    LUM

    450

    175

    CFW

    G.09

    B.WC

    CL 2800 CL 2800

    CFW

    G.07

    G.WC

    LU

    M

    MOUNTED @ 4000 ABOVE FFLFROM ROOF FRAMING TO ENGS DETAILSRHS CURTAIN BAR SUSPENDED

    2280

    2175

    2280

    3018

    600

    VP

    LADDER FIXING FRAMESTAINLESS STEEL

    EAVES AND OVERHANG DIMENSIONS AND DETAILSREFER TO SECTION DETAILS FOR ROOFNOTE:

    EAVES AND OVERHANG DIMENSIONS AND DETAILSREFER TO SECTION DETAILS FOR ROOFNOTE:

    HEATER HEATER

    3000 ABOVE FFLMOUNTED AT

    3600 ABOVE FFLMOUNTED AT

    3600 ABOVE FFLMOUNTED AT

    3000 ABOVE FFLMOUNTED AT

    3600 ABOVE FFLMOUNTED AT

    3000 ABOVE FFLMOUNTED AT

    3000 ABOVE FFLMOUNTED AT

    3000 ABOVE FFLMOUNTED AT

    3000 ABOVE FFLMOUNTED AT

    4800 ABOVE FFLMOUNTED AT

    4800 ABOVE FFLMOUNTED AT

    4800 ABOVE FFLMOUNTED AT

    4800 ABOVE FFLMOUNTED AT

    4800 ABOVE FFLMOUNTED AT

    4800 ABOVE FFLMOUNTED AT

    3000 ABOVE FFLMOUNTED AT

    3000 ABOVE FFLMOUNTED AT

    3000 ABOVE FFLMOUNTED AT

    3000 ABOVE FFLMOUNTED AT

    3600 ABOVE FFLMOUNTED AT

    3600 ABOVE FFLMOUNTED AT

    3600 ABOVE FFLMOUNTED AT

    HEATER HEATER

    37953795

    37953795

    300

    LU

    ML

    UM

    LU

    ML

    UM

    LU

    M

    WHD

    CEILINGRAKED

    CMA

    CMA

    RWPRWG RWPRWP RWG

    RWP

    RBR

    RW

    G

    RWP

    RWP

    RWP

    RW

    GR

    WG

    RBR

    1873

    3822

    2580

    2580

    2520

    2520

    1615

    SC

    SC

    SC

    SC

    SC

    SC

    SC

    750750

    LUM

    LU

    M

    CL=

    SL=

    CDT

    CFS FIBRE CEMENT CEILING

    CFW

    CMS

    PLASTERBOARD CEILINGCPB

    CPL

    CPP

    CORRUGATED METAL SOFFIT

    PLYWOOD CEILING

    CEILING LEVEL

    SOFFIT LEVEL

    700 x 700 ACRYLIC PANEL

    MICROPHONE

    CEILING LEGEND

    CEMENT CEILINGMOISTURE RESISTANT FIBRE

    CEILINGPERFORATED PLASTERBOARD

    DIFFUSERTRANSLUSCENT CEILING

    CAI

    CENTER LINE600mm WIDE EITHER SIDE OF WALL 11kg/m,ACOUSTIC INSULATION 75mm THICK

    BLOCK WALL

    BRICK WALL

    OF ROOF STRUCTUREBRICK WALL TO U/S

    WALL LEGEND