WALL HOLES FOR SCREW FIXING Differential temperature LEDs to turn the pump ON Differential temperature button to turn the pump ON Pump operation mode control button Overheating control button Anti-freeze control button Pump OFF indication LED Overheating protection indication led Pump operation mode indicator LED Differential temperature button to turn the pump OFF Differential temperature LEDs to turn the pump OFF Pump ON indication LED Anti-freeze protection indication LED 5. DISPLAY IDENTIFICATION AND CONTROL BUTTONS ANASOL 7. INSTRUMENT FIXATION MODE DIN RAIL WALL Wall DIN rail Instrument Spare reinforce screws (not included) 7.1 DIN mount fixation 7.2 Screw fixation (wall-mounted) Screws for fixation (not included) 6. WIRING DIAGRAM Mere illustrative images 4.4 - Pump operation mode Press and select the pump operation mode, as follows: OFF - Manual mode. Pump is always OFF AUT - Automatic mode. Pump activation following the user settings. ON - Manual mode. Pump is always ON. 1. DESCRIPTION ANASOL is a differential thermostat for solar heating that acts through the differential temperature between sensor S1 (solar collector) and sensor S2 (pool or boiler). Controller for pumped solar heating systems applications with overheating and anti-freeze functions. It has anti-freeze function(protection of pipes), prevents water overheating (for pools) also has manual control of the circulation pump. 2. APPLICATION Solar heating system for pool or boiler water. 3. TECHNICAL SPECIFICATIONS - Power supply: 115 or 230 Vac ±15% (50/60 Hz) -Control temperature: Sensor S1- Metal capsule - Silicone: -50 to 200 °C* / -58 to 392°F** Sensor S2 - Plastic capsule - PVC: -50 to 105 °C* / -58 to 221°F** - Load current: 16(8) A / 250Vac 1HP - Dimensions (W x H x L): 77 x 39 x 97mm - Differential to turn the pump ON: from 1 to 10 ºC* / 2 to 20°F** - Differential to turn the pump OFF: from 1 to 10 ºC* / 2 to 20°F** - Operating temperature: 0 to 45°C* / 32 to 113°F** - Operation humidity: 10 to 90% RH (without condensation) * Celsius (Cº) ANASOL model **Fahrenheit (Fº) ANASOL model 4. SETTINGS 4.1 - Adjustment To set the controller functions the correspondent key should be press and hold for three seconds until the led starts to flash. After this first step all functions can be set as desired. The adjustment validation only will be effective after the led stop flashing (three seconds after the key idleness). 4.1.1 - Differential to turn the pump ON Press to set this function. The led shows the temperature differential to activate the pump. 4.1.2 - Differential to turn the pump OFF Press to set this function. The led shows the temperature differential to deactivate the pump. Example: T ON = 8°C T OFF = 2°C When the difference between sensor 1 and sensor 2 goes higher than 8ºC it will activate the pump. The pump will only shutdown when the differential temperature between both sensors reach less than 2ºC degrees. 4.2 - Protection against overheating Allows to adjust the temperature to protect against overheating of the sensors S1 and S2, shutting down the water circulation pump if the temperature reaches the selected values. - Protection against overheating in Sensor S1: The pump is switched off to prevent the superheated water circulates through the pipes and damage them (if PVC pipes are used). - Protection against overheating in Sensor S2: The pump is switched off to keep the thermal comfort of reservoir water, mainly used in swimming pools. The hysteresis of this function has a fixed value of C * 2 / 4 F ** that will reactivate the water pump when the temperature decreases to the selected value minus the hysteresis. To disable this function select “OFF” through . DIFFERENTIAL FOR SOLAR HEATING THERMOSTAT 4.5 - Signaling The PUMP ON led ON indicates that the “NO” output is activated (pump ON). The PUMP OFF led ON indicates that the “NC” output is activated (pump OFF). Flashing PUMP ON and PUMP OFF leds indicates the following: -Some of the temperature sensors are disconnected -Temperature out of control range The T ON and T OFF leds flashing indicates the following: -The temperature setting is higher than . 4.3 - Anti-freeze protection If the temperature in the sensor 1 reaches lower values than set by the user, the water pump will activate to prevent water freezing in the pipes. The anti-freeze function has 4ºC / 8 ºF as preset value to deactivate the water pump when the temperature on sensor 1 goes over the freeze protection value, plus the differential to deactivate the pump (hysteresis). To disable this function select “OFF” through When activated by this function the water pump will keep 3 minutes (minimum) activated, regardless of the sensor 1 temperature. * ** . . 1 2 Mere illustrative images Ver.02 The LED always shows the configuration of sensor S2. To see the configuration of the sensor S1, briefly press the button, the LED will blink quickly in the corresponding value. Sensor 2 indication To adjust the overheating protection in the sensor S2 press for 3 seconds (LED blinking slowly). Sensor 1 indication To adjust the overheating protection in the sensor S1 press for 10 seconds (Led blinking quickly). Power supply Pump Load supply 0 5 - 6 115V 5 - 7 230V 115V 230V Sensor S1- Metal capsule - Silicone Panels or solar collector Sensor S2- Reservoir/Pool Plastic capsule - PVC NEWANASOL02-04T-12219

Upload: others

Post on 22-Jun-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: NEWANASOL02-04T-12219- FORMATO PARA …...-Temperature out of control range The T ONand T OFF leds flashing indicates the following:-The temperature setting is higher than . 4.3 -

WALL

HOLES

FOR SCREW FIXING

Differential temperatureLEDs to turn thepump ON

Differential temperaturebutton to turn the pump ON

Pump operation modecontrol button

Overheating control button

Anti-freeze control button

Pump OFF indication LED

Overheating protection indication led

Pump operation modeindicator LED

Differential temperaturebutton to turn the pump OFF

Differential temperature LEDsto turn the pump OFF

Pump ONindication LED

Anti-freeze protectionindication LED

5. DISPLAY IDENTIFICATION AND CONTROL BUTTONS

ANASOL

7. INSTRUMENT FIXATION MODE

DIN RAIL

WALLWall

DIN rail

Instrument

Spare reinforce screws (not included)

7.1 DIN mount fixation

7.2 Screw fixation (wall-mounted)

Screws for fixation (not included)

6. WIRING DIAGRAM

Mer

e ill

ustr

ativ

e im

ages

4.4 - Pump operation modePress and select the pump operation mode, as follows:

OFF - Manual mode. Pump is always OFFAUT - Automatic mode. Pump activation following the user settings.ON - Manual mode. Pump is always ON.

1. DESCRIPTIONANASOL is a differential thermostat for solar heating that acts through the differential temperature between sensor S1 (solar collector) and sensor S2 (pool or boiler). Controller for pumped solar heating systems applications with overheating and anti-freeze functions.It has anti-freeze function(protection of pipes), prevents water overheating (for pools) also has manual control of the circulation pump.

2. APPLICATIONSolar heating system for pool or boiler water.

3. TECHNICAL SPECIFICATIONS - Power supply: 115 or 230 Vac ±15% (50/60 Hz) -Control temperature: Sensor S1- Metal capsule - Silicone: -50 to 200 °C* / -58 to 392°F** Sensor S2 - Plastic capsule - PVC: -50 to 105 °C* / -58 to 221°F** - Load current: 16(8) A / 250Vac 1HP - Dimensions (W x H x L): 77 x 39 x 97mm - Differential to turn the pump ON: from 1 to 10 ºC* / 2 to 20°F**- Differential to turn the pump OFF: from 1 to 10 ºC* / 2 to 20°F** - Operating temperature: 0 to 45°C* / 32 to 113°F**- Operation humidity: 10 to 90% RH (without condensation)* Celsius (Cº) ANASOL model**Fahrenheit (Fº) ANASOL model

4. SETTINGS

4.1 - AdjustmentTo set the controller functions the correspondent key should be press and hold for three seconds until the led starts to flash. After this first step all functions can be set as desired. The adjustment validation only will be effective after the led stop flashing (three seconds after the key idleness).

4.1.1 - Differential to turn the pump ONPress to set this function. The led shows the temperature differential to activate the pump.4.1.2 - Differential to turn the pump OFFPress to set this function. The led shows the temperature differential to deactivate the pump. Example: T ON = 8°C

T OFF = 2°CWhen the difference between sensor 1 and sensor 2 goes higher than 8ºC it will activate the pump. The pump will only shutdown when the differential temperature between both sensors reach less than 2ºC degrees.

4.2 - Protection against overheatingAllows to adjust the temperature to protect against overheating of the sensors S1 and S2, shutting down the water circulation pump if the temperature reaches the selected values.

- Protection against overheating in Sensor S1: The pump is switched off to prevent the superheated water circulates through the pipes and damage them (if PVC pipes are used).- Protection against overheating in Sensor S2: The pump is switched off to keep the thermal comfort of reservoir water, mainly used in swimming pools.

The hysteresis of this function has a fixed value of C * 2 / 4 F ** that will reactivate the water pump when the temperature decreases to the selected value minus the hysteresis. To disable this function select “OFF” through .

DIFFERENTIAL FOR SOLAR HEATING

THERMOSTAT

4.5 - SignalingThe PUMP ON led ON indicates that the “NO” output is activated (pump ON). The PUMP OFF led ON indicates that the “NC” output is activated (pump OFF). Flashing PUMP ON and PUMP OFF leds indicates the following:

-Some of the temperature sensors are disconnected -Temperature out of control rangeThe T ON and T OFF leds flashing indicates the following:

-The temperature setting is higher than .

4.3 - Anti-freeze protectionIf the temperature in the sensor 1 reaches lower values than set by the user, the water pump will activate to prevent water freezing in the pipes. The anti-freeze function has 4ºC / 8 ºF as preset value to deactivate the water pump when the temperature on sensor 1 goes over the freeze protection value, plus the differential to deactivate the pump (hysteresis). To disable this function select “OFF” through

When activated by this function the water pump will keep 3 minutes (minimum) activated, regardless of the sensor 1 temperature.

* **

. .

1

2

Mer

e ill

ustr

ativ

e im

ages

Ver.02

The LED always shows the configuration of sensor S2. To see the configuration of the sensor S1, briefly press the button, the LED will blink quickly in the corresponding value.

Sensor 2 indication To adjust the overheating protection in the sensor S2 press for 3 seconds (LED blinking slowly).

Sensor 1 indication To adjust the overheating protection in the sensor S1press for 10 seconds (Led blinking quickly).

Powersupply

Pump

Loadsupply

0

5 - 6 115V 5 - 7 230V

115

V

230

V

Sensor S1- Metal capsule - Silicone Panels or solar collector

Sensor S2- Reservoir/Pool

Plastic capsule - PVC

NE

WA

NA

SO

L0

2-0

4T

-12

21

9

Page 2: NEWANASOL02-04T-12219- FORMATO PARA …...-Temperature out of control range The T ONand T OFF leds flashing indicates the following:-The temperature setting is higher than . 4.3 -

IMPORTANTAs chapters of IEC 60364 norm: 1: Install protectors against overloads on power supply.2: Sensor cables and computer signs can be together, however not in the same conduction; where there power supply and load drive.3: Install suppresors (RC filters) in parallel to loads to increase the relays function.

Wiring diagram of suppresor in contactors Wiring diagram of suppresor linking in loads direct drive

LoadFor direct activation the maximumspecified current should be takeninto consideration.

A1

A2

A1 and A2 are the contactor coil.

Sup

pres

or

Sup

pres

or

ENVIRONMENTAL INFORMATIONPackage:The packages material are 100% recyclable. Just dispose it through specialized recyclers.

Products:The electro components of Full Gauge controllers can be recycled or reused if it is disassembled for specialized companies.

Disposal:Do not burn or throw in domestic garbage the controllers which have reached the end-of-life. Observe the respectively law in your region concerning the environmental responsible manner of dispose its devices. In case of any doubts, contact Full Gauge controls for assistance.