newanasol02-04t-12219- formato para …...-temperature out of control range the t onand t off leds...
TRANSCRIPT
WALL
HOLES
FOR SCREW FIXING
Differential temperatureLEDs to turn thepump ON
Differential temperaturebutton to turn the pump ON
Pump operation modecontrol button
Overheating control button
Anti-freeze control button
Pump OFF indication LED
Overheating protection indication led
Pump operation modeindicator LED
Differential temperaturebutton to turn the pump OFF
Differential temperature LEDsto turn the pump OFF
Pump ONindication LED
Anti-freeze protectionindication LED
5. DISPLAY IDENTIFICATION AND CONTROL BUTTONS
ANASOL
7. INSTRUMENT FIXATION MODE
DIN RAIL
WALLWall
DIN rail
Instrument
Spare reinforce screws (not included)
7.1 DIN mount fixation
7.2 Screw fixation (wall-mounted)
Screws for fixation (not included)
6. WIRING DIAGRAM
Mer
e ill
ustr
ativ
e im
ages
4.4 - Pump operation modePress and select the pump operation mode, as follows:
OFF - Manual mode. Pump is always OFFAUT - Automatic mode. Pump activation following the user settings.ON - Manual mode. Pump is always ON.
1. DESCRIPTIONANASOL is a differential thermostat for solar heating that acts through the differential temperature between sensor S1 (solar collector) and sensor S2 (pool or boiler). Controller for pumped solar heating systems applications with overheating and anti-freeze functions.It has anti-freeze function(protection of pipes), prevents water overheating (for pools) also has manual control of the circulation pump.
2. APPLICATIONSolar heating system for pool or boiler water.
3. TECHNICAL SPECIFICATIONS - Power supply: 115 or 230 Vac ±15% (50/60 Hz) -Control temperature: Sensor S1- Metal capsule - Silicone: -50 to 200 °C* / -58 to 392°F** Sensor S2 - Plastic capsule - PVC: -50 to 105 °C* / -58 to 221°F** - Load current: 16(8) A / 250Vac 1HP - Dimensions (W x H x L): 77 x 39 x 97mm - Differential to turn the pump ON: from 1 to 10 ºC* / 2 to 20°F**- Differential to turn the pump OFF: from 1 to 10 ºC* / 2 to 20°F** - Operating temperature: 0 to 45°C* / 32 to 113°F**- Operation humidity: 10 to 90% RH (without condensation)* Celsius (Cº) ANASOL model**Fahrenheit (Fº) ANASOL model
4. SETTINGS
4.1 - AdjustmentTo set the controller functions the correspondent key should be press and hold for three seconds until the led starts to flash. After this first step all functions can be set as desired. The adjustment validation only will be effective after the led stop flashing (three seconds after the key idleness).
4.1.1 - Differential to turn the pump ONPress to set this function. The led shows the temperature differential to activate the pump.4.1.2 - Differential to turn the pump OFFPress to set this function. The led shows the temperature differential to deactivate the pump. Example: T ON = 8°C
T OFF = 2°CWhen the difference between sensor 1 and sensor 2 goes higher than 8ºC it will activate the pump. The pump will only shutdown when the differential temperature between both sensors reach less than 2ºC degrees.
4.2 - Protection against overheatingAllows to adjust the temperature to protect against overheating of the sensors S1 and S2, shutting down the water circulation pump if the temperature reaches the selected values.
- Protection against overheating in Sensor S1: The pump is switched off to prevent the superheated water circulates through the pipes and damage them (if PVC pipes are used).- Protection against overheating in Sensor S2: The pump is switched off to keep the thermal comfort of reservoir water, mainly used in swimming pools.
The hysteresis of this function has a fixed value of C * 2 / 4 F ** that will reactivate the water pump when the temperature decreases to the selected value minus the hysteresis. To disable this function select “OFF” through .
DIFFERENTIAL FOR SOLAR HEATING
THERMOSTAT
4.5 - SignalingThe PUMP ON led ON indicates that the “NO” output is activated (pump ON). The PUMP OFF led ON indicates that the “NC” output is activated (pump OFF). Flashing PUMP ON and PUMP OFF leds indicates the following:
-Some of the temperature sensors are disconnected -Temperature out of control rangeThe T ON and T OFF leds flashing indicates the following:
-The temperature setting is higher than .
4.3 - Anti-freeze protectionIf the temperature in the sensor 1 reaches lower values than set by the user, the water pump will activate to prevent water freezing in the pipes. The anti-freeze function has 4ºC / 8 ºF as preset value to deactivate the water pump when the temperature on sensor 1 goes over the freeze protection value, plus the differential to deactivate the pump (hysteresis). To disable this function select “OFF” through
When activated by this function the water pump will keep 3 minutes (minimum) activated, regardless of the sensor 1 temperature.
* **
. .
1
2
Mer
e ill
ustr
ativ
e im
ages
Ver.02
The LED always shows the configuration of sensor S2. To see the configuration of the sensor S1, briefly press the button, the LED will blink quickly in the corresponding value.
Sensor 2 indication To adjust the overheating protection in the sensor S2 press for 3 seconds (LED blinking slowly).
Sensor 1 indication To adjust the overheating protection in the sensor S1press for 10 seconds (Led blinking quickly).
Powersupply
Pump
Loadsupply
0
5 - 6 115V 5 - 7 230V
115
V
230
V
Sensor S1- Metal capsule - Silicone Panels or solar collector
Sensor S2- Reservoir/Pool
Plastic capsule - PVC
NE
WA
NA
SO
L0
2-0
4T
-12
21
9
IMPORTANTAs chapters of IEC 60364 norm: 1: Install protectors against overloads on power supply.2: Sensor cables and computer signs can be together, however not in the same conduction; where there power supply and load drive.3: Install suppresors (RC filters) in parallel to loads to increase the relays function.
Wiring diagram of suppresor in contactors Wiring diagram of suppresor linking in loads direct drive
LoadFor direct activation the maximumspecified current should be takeninto consideration.
A1
A2
A1 and A2 are the contactor coil.
Sup
pres
or
Sup
pres
or
ENVIRONMENTAL INFORMATIONPackage:The packages material are 100% recyclable. Just dispose it through specialized recyclers.
Products:The electro components of Full Gauge controllers can be recycled or reused if it is disassembled for specialized companies.
Disposal:Do not burn or throw in domestic garbage the controllers which have reached the end-of-life. Observe the respectively law in your region concerning the environmental responsible manner of dispose its devices. In case of any doubts, contact Full Gauge controls for assistance.