new plant seismic issues resolution program – …new plant seismic program task s2.1(a) • new...
TRANSCRIPT
![Page 1: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/1.jpg)
New Plant Seismic Issues Resolution Program – Follow-Up Discussion of S2.1 Incoherence Project
December 20-21, 2006
Stephen ShortJim JohnsonGreg Hardy
![Page 2: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/2.jpg)
2© 2006 Electric Power Research Institute, Inc. All rights reserved.
New Plant Seismic Program Task S2.1(a)
• New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response” EPRI No. 1013504, November 2006
• Meeting Topics
– Progress Report on S2.1a Actions from October 24-25 NRC Meetings (9 Action Items Resulting from Meeting)• Coherent-Incoherent Response
• Important Fixed-Base Modes
• Validation
• CLASSI and SASSI Comparison Studies
• NRC Comments to New Material
![Page 3: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/3.jpg)
October S2.1a Action Items
• Action #1 - The EPRI Project Team will review the implications of a change in the coherency function to address the low values at depths between 10 and 20 m (see Topic 1 task list). EPRI will develop a recommendation on how to address a potential variation in the coherency function with depth. Assuming that a change to the coherency function with depth is determined, new foundation and structure responses will be analyzed to demonstrate the effects of the changes as appropriate.
• Status
– New coherency function at depth defined on December 9th
– Project team recommends using this new function for embedded structures at all elevations
– Starting the review of the effects of the new coherency function for comparison to original (surface) function, mid January completion
– Recommendation for surface founded structures pending results of study
3© 2006 Electric Power Research Institute, Inc. All rights reserved.
![Page 4: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/4.jpg)
October S2.1a Action Items
• Action #2 - Greg Hardy will arrange a conference call with Dr. Abrahamson and interested parties to discuss the following questions: If the basic site seismic hazard is defined from recorded ground motions using the entire strong motion window, why does the coherency evaluation consider only the plane S-wave contribution? Does the wave passage effect in the SSI calculation induce response in excess to that caused by the consideration of the plane wave coherency only?
• Status
– Requested call conducted 11/6/06
–Clarification of several issues
–NRC consultants agreed to send written questions to clarify remaining items
4© 2006 Electric Power Research Institute, Inc. All rights reserved.
![Page 5: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/5.jpg)
5© 2006 Electric Power Research Institute, Inc. All rights reserved.
October S2.1a Action Items: #2 Cont.
• Follow up Questions from Aspa Zerva and Carl Costantino sent by NRC (11/7/06)
• “The following questions are posed to NEI/EPRI regarding the useof plane wave coherency in the SSI calculations
a) If the basic site seismic hazard is defined from recorded ground motions using the entire strong motion window, why does the coherency evaluation consider only the plane S-wave contribution?
b) Does the wave passage effect in the SSI calculation induce response in excess to that caused by the consideration of the plane wave coherency only?”
• Response to Questions via email on 12/10/06 from Norm Abrahamson and Jim Johnson
![Page 6: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/6.jpg)
October S2.1a Action Items
• Action #3 - Changes to the report will be made by ARES:a. To address a number of editorial items that were identifiedb. Wording will also be changed to state that the coherency function “was assumed to be independent of depth” not “was independent of depth”.c. Reference will be made to Dr. Veletsos’ earlier study on incoherency that describes the “approximate deterministic” approach and a descriptive comparison of the ARES and Veletsos approaches will be made.d. Chapter 4 will be amended to address the translation and rotation combination.e. The use of random vibration theory in addition to SRSS to determine the combination of translation and rotation for edge translations will be considered (ARES) and changes to figures may be incorporated.
6© 2006 Electric Power Research Institute, Inc. All rights reserved.
![Page 7: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/7.jpg)
October S2.1a Action Items
• Action Item #3 - Status
– All items requested have been completed and were incorporated into the recent November EPRI report
7© 2006 Electric Power Research Institute, Inc. All rights reserved.
![Page 8: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/8.jpg)
October S2.1a Action Items
• Action #4 - Dr. Costantino will schedule a discussion with Bechtel on SASSI details relative to the input motion power spectral density (PSD) preservation and on load vectors.
• Status
– Believe this discussion was conducted? Dr. Costantino to provide summary of results of conversation.
8© 2006 Electric Power Research Institute, Inc. All rights reserved.
![Page 9: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/9.jpg)
October S2.1a Action Items
• Action #5 - ARES will provide additional information on the main structural model results (frequencies, mode shapes, eigenfunctions and participation factors up to about 30 Hz) in order for the NRC consultants to fully understand the responses.
• Status
– Studies completed to provide requested information
– Presented in following section of presentation
9© 2006 Electric Power Research Institute, Inc. All rights reserved.
![Page 10: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/10.jpg)
October S2.1a Action Items
• Action #6 - ARES to discuss with EPRI a path generating documentation and a version of CLASSI (can be kept proprietary) with incoherency to the NRC for specific use in reviews on this project.
• Status
– Cleared the legal hurdles
– In process of documenting code for use/understanding by others
– Portions to be sent at the end of December
– Complete package in late January
10© 2006 Electric Power Research Institute, Inc. All rights reserved.
![Page 11: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/11.jpg)
October S2.1a Action Items
• Action #7 - Discuss and resolve the issue of whether both versions of SASSI and CLASSI get the increase in the low-frequency region due to the rotations. There should be a problem that is done consistently with all codes. The resolution will be communicated to the NRC.
• Status
– Evaluation in process
– Preliminary results presented in following section
– Still have work to do to complete study
11© 2006 Electric Power Research Institute, Inc. All rights reserved.
![Page 12: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/12.jpg)
October S2.1a Action Items
• Action #8 - Discuss/implement ways for industry to participate in an effort to generate an NRC/Industry consensus on elements of the seismic qualification process that have not been finalized, e.g., :a. Convolution for soil, rock and deep soil sitesb. Site profile properties uncertainty usage for SSI analysesc. Minimum seismic design levelsd. Site response assessment methods
• Status
– NEI meeting held Dec 13 to generate industry input/recommendations
– NRC meeting held Dec 14 with industry
– Further interactions requested relative to draft SRP sections
12© 2006 Electric Power Research Institute, Inc. All rights reserved.
![Page 13: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/13.jpg)
October S2.1a Action Items
• Action #9 - Plots of the free-field ground motion, SSI coherent and SSI Incoherent Fourier Spectra for figures such as 5-80 and 5-81 of the EPRI Report 1013504 to help demonstrate the effects of SSI (coherent or incoherent) on the seismic response of foundations and structures.
• Status
– Evaluations completed and will be presented in the following presentation sections
13© 2006 Electric Power Research Institute, Inc. All rights reserved.
![Page 14: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/14.jpg)
14© 2006 Electric Power Research Institute, Inc. All rights reserved.
Coherent – Incoherent Foundation Response
![Page 15: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/15.jpg)
15© 2006 Electric Power Research Institute, Inc. All rights reserved.
Foundation Response: Review of Free-Field, Coherent, and Incoherent Response
• Objective: Demonstrate the characteristics of the foundation response for coherent and incoherent assumptions
• Rock site profile and high frequency ground motion
• Kinematic interaction – response of a rigid, massless foundation subjected to the free-field ground motion - also called foundation input motion (FIM)
– Coherent wave assumption – FIM = free-field ground motion
– Incoherent wave assumption – FIM = (free-field ground motion) * Incoherency Transfer Functions (ITFs)
• SSI response
– Structure model supported on 150 ft square foundation
– Coherent wave assumption – Inertial interaction
– Incoherent wave assumption – Kinematic and inertial interaction
![Page 16: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/16.jpg)
16© 2006 Electric Power Research Institute, Inc. All rights reserved.
Rock and Soil Site ProfileShear Wave Velocities vs. Depth
-6000
-5000
-4000
-3000
-2000
-1000
0
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000
Shear Wave Velocity, ft/sec
De
pth
, ft
EPRI 2003 Bedrock Boundary
Soil
-160
-140
-120
-100
-80
-60
-40
-20
0
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000
Shear Wave Velocity, ft/sec
De
pth
, ft
EPRI 2003 Bedrock Boundary
Rock
![Page 17: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/17.jpg)
17© 2006 Electric Power Research Institute, Inc. All rights reserved.
Site-Specific Response Spectra forRock Site at Ground Surface (Depth 0-ft)
0
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
0.1 1 10 100
Frequency, Hz
Sp
ectr
al A
cc
eler
atio
n,
g
Horizontal
Vertical
RG 1.60 Horizontal (ZPA=0.3g)
RG 1.60 Vertical (ZPA=0.3g)
5% Damping
![Page 18: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/18.jpg)
18© 2006 Electric Power Research Institute, Inc. All rights reserved.
Free-Field vs. Foundation Input Motion (FIM) (Kinematic interaction)
• Response of a rigid, massless foundation subjected to the incoherent wave field defined by the Abrahamson ground motion coherency functions
• Free-field ground motion defined by acceleration time histories (horizontal and vertical)
• Foundation is square - 150 ft on a side
• Rock site profile
• FIM calculated by applying the Incoherency Transfer Functions to the Fourier transform of the free-field ground motions – Inverse Fourier transform to obtain time histories on foundation
• Response spectra (5% damped) and Fourier Amplitude Spectra calculated
![Page 19: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/19.jpg)
19© 2006 Electric Power Research Institute, Inc. All rights reserved.
Response Spectra: Free-Field vs. Foundation Input Motion (Incoherent wave assumption) –Horizontal
Response Spectra, Foundation, x-Direction
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
0.1 1 10 100
Frequency (Hz)
Sp
ectr
al A
ccel
erat
ion
(g
)
SSI, Incoherent FIM, x-direction
Fixed Base, x-direction
![Page 20: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/20.jpg)
20© 2006 Electric Power Research Institute, Inc. All rights reserved.
Fourier Amplitude Spectra: Free-Field vs. Foundation Input Motion (Incoherent wave assumption) – Horizontal
Fourier Amplitude Spectra, Foundation, x-Direction
0
0.005
0.01
0.015
0.02
0.025
0.03
0.035
0.1 1 10 100
Frequency (Hz)
FA
S
Fixed Base, x-direction
SSI, Incoherent FIM, x-direction
![Page 21: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/21.jpg)
21© 2006 Electric Power Research Institute, Inc. All rights reserved.
Response Spectra: Free-Field vs. Foundation Input Motion (Incoherent wave assumption) -Vertical
Response Spectra, Foundation, z-Direction
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
0.1 1 10 100
Frequency (Hz)
Sp
ect
ral A
cce
lera
tio
n (
g)
SSI, Incoherent FIM, z-direction
Fixed Base, z-direction
![Page 22: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/22.jpg)
22© 2006 Electric Power Research Institute, Inc. All rights reserved.
Fourier Amplitude Spectra: Free-Field vs. Foundation Input Motion (Incoherent wave assumption) – Vertical
Fourier Amplitude Spectra, Foundation, z-Direction
0
0.005
0.01
0.015
0.02
0.025
0.03
0.035
0.04
0.045
0.1 1 10 100
Frequency (Hz)
FA
S
Fixed Base, z-direction
SSI, Incoherent FIM, z-direction
![Page 23: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/23.jpg)
23© 2006 Electric Power Research Institute, Inc. All rights reserved.
Free-Field vs. FIM vs. Foundation Response(SSI for coherent and incoherent wave assumptions)
• Free-field ground motion defined by acceleration time histories (horizontal and vertical)
• Rock site profile
• Foundation is square - 150 ft on a side – 15 ft thick with mass properties
• Advanced reactor structure stick model with eccentricities (160 modes)
• Coherent wave assumption – Inertial interaction (Kinematic interaction = unity)
• Incoherent wave assumption – Kinematic and inertial interaction
• Response spectra (5% damped) and Fourier Amplitude Spectra calculated
![Page 24: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/24.jpg)
24© 2006 Electric Power Research Institute, Inc. All rights reserved.
Advanced ReactorStructure StickModel with Outriggersand Offset MassCenters
24© 2006 Electric Power Research Institute, Inc. All rights reserved.
![Page 25: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/25.jpg)
25© 2006 Electric Power Research Institute, Inc. All rights reserved.
Response Spectra: Free-Field vs. FIM vs. Foundation Response (SSI for coherent and incoherent wave assumptions) - Horizontal
Response Spectra, Foundation, x-Direction
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
0.1 1 10 100
Frequency (Hz)
Sp
ect
ral A
ccel
era
tio
n (
g)
SSI, Coherent, x-direction
SSI, Incoherent, x-direction
SSI, Incoherent FIM, x-direction
Fixed Base, x-direction
![Page 26: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/26.jpg)
26© 2006 Electric Power Research Institute, Inc. All rights reserved.
Fourier Amplitude Spectra: Free-Field vs. FIM vs. Foundation Response (SSI for coherent and incoherent wave assumptions) - Horizontal
Fourier Amplitude Spectra, Foundation, x-Direction
0
0.01
0.02
0.03
0.04
0.05
0.06
0.1 1 10 100
Frequency (Hz)
FA
S
SSI, Coherent, x-direction
SSI, Incoherent, x-direction
Fixed Base, x-direction
SSI, Incoherent FIM, x-direction
![Page 27: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/27.jpg)
27© 2006 Electric Power Research Institute, Inc. All rights reserved.
Response Spectra: Free-Field vs. FIM vs. Foundation Response (SSI for coherent and incoherent wave assumptions) – Vertical
Response Spectra, Foundation, z-Direction
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
0.1 1 10 100
Frequency (Hz)
Sp
ect
ral A
cce
lera
tio
n (
g)
SSI, Coherent, z-direction
SSI, Incoherent, z-direction
SSI, Incoherent FIM, z-direction
Fixed Base, z-direction
![Page 28: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/28.jpg)
28© 2006 Electric Power Research Institute, Inc. All rights reserved.
Fourier Amplitude Spectra: Free-Field vs. FIM vs. Foundation Response (SSI for coherent and incoherent wave assumptions) – Vertical
Fourier Amplitude Spectra, Foundation, z-Direction
0
0.005
0.01
0.015
0.02
0.025
0.03
0.035
0.04
0.045
0.1 1 10 100
Frequency (Hz)
FA
S
SSI, Coherent, z-direction
SSI, Incoherent, z-direction
Fixed Base, z-direction
SSI, Incoherent FIM, z-direction
![Page 29: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/29.jpg)
29© 2006 Electric Power Research Institute, Inc. All rights reserved.
Foundation Response: Review of Free-Field, Coherent, and Incoherent Response
• Response spectra and Fourier amplitude spectra demonstrate and quantify the effect on the foundation of:
– Kinematic interaction due to incoherency of ground motion on a rigid, massless foundation
– Soil-structure interaction effects on foundation response • Kinematic and inertial interaction for incoherent ground motion
• Inertial interaction for coherent ground motion (Kinematic interaction = unity)
– EPRI Report No. 1013504, Appendix C Figs. C-16 vs. C-4, C-17 vs. C-5, C-18 vs. C-6, further validate the effect of SSI on response of the foundation - coherent motion
![Page 30: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/30.jpg)
30© 2006 Electric Power Research Institute, Inc. All rights reserved.
Identification of Important Modes for Simplified Modeling and Behavior Insight
![Page 31: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/31.jpg)
31© 2006 Electric Power Research Institute, Inc. All rights reserved.
Identification of Important Modes for Simplified Modeling and Behavior Insight
• Advanced reactor structure stick model with eccentricities
– 160 fixed-base modes model the dynamic characteristics of the structure
– Frequencies 3.0 Hz – 141 Hz
– Total mass (x = 92.7%, y = 92.5%, z = 93.1%)
• Three sticks are coupled at various locations – modes are coupled
• Relative mass distribution
– ASB – 86%
– CIS – 11%
– SCV – less than 5%
![Page 32: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/32.jpg)
32© 2006 Electric Power Research Institute, Inc. All rights reserved.
Identification of Important Modes for Simplified Modeling and Behavior Insight
• Measure of importance = Phi * Gamma
– Phi – eigenvector value for DOF of interest
– Gamma – modal participation factor for base excitation direction of interest
– Base translations and rotations are important –identification based on translations – generally same modes are important for rotations
– Phi * Gamma • Signed, but absolute value plotted for clarity
• Sum of Phi * Gamma = 1.0 or 0.0 for nodes and DOFs considered
![Page 33: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/33.jpg)
33© 2006 Electric Power Research Institute, Inc. All rights reserved.
Advanced ReactorStructure Stick Model
33© 2006 Electric Power Research Institute, Inc. All rights reserved.
![Page 34: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/34.jpg)
34© 2006 Electric Power Research Institute, Inc. All rights reserved.
Advanced ReactorStructure StickModel with Outriggersand Offset MassCenters
34© 2006 Electric Power Research Institute, Inc. All rights reserved.
![Page 35: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/35.jpg)
35© 2006 Electric Power Research Institute, Inc. All rights reserved.
Important Modes – Top of ASB
Contributions to Phi*Gamma,Top of ASB - x
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
0 5 10 15 20 25 30 35 40 45 50
Mode Number
Ph
i*G
amm
a
Effect of Fdn-x
Effect of Fdn-y
Effect of Fdn-z
![Page 36: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/36.jpg)
36© 2006 Electric Power Research Institute, Inc. All rights reserved.
Important Modes – Top of ASB
Top of ASB-x Modal Mass as Percent of Total
Mode No Frequency
(Hz) Damping
x y z Fnd
Direction
2 3.21 0.04 20.1 0.0 0.0 x 8 6.54 0.04 3.3 2.0 0.0 x & y 9 6.57 0.04 2.6 1.8 0.0 x & y
14 10.05 0.04 15.5 0.4 0.0 x 18 13.83 0.04 3.6 0.3 0.0 x 22 15.81 0.04 2.5 0.3 0.0 x 29 20.55 0.04 3.2 0.3 0.0 x 32 21.74 0.04 0.2 2.5 0.0 y
![Page 37: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/37.jpg)
37© 2006 Electric Power Research Institute, Inc. All rights reserved.
Important Modes – Top of ASB
Contributions to Phi*Gamma, Top of ASB-y
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
0 5 10 15 20 25 30 35 40 45 50
Mode Number
Ph
i*G
amm
a
Effect of Fdn-x
Effect of Fdn-y
Effect of Fdn-z
![Page 38: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/38.jpg)
38© 2006 Electric Power Research Institute, Inc. All rights reserved.
Important Modes – Top of ASB
Top of ASB-y Modal Mass as Percent of Total
Mode No Frequency
(Hz) Damping
x y z Fnd
Direction
1 3.00 0.04 0.0 21.6 0.0 y 6 6.14 0.04 0.0 5.3 0.0 y 8 6.54 0.04 3.3 2.0 0.0 x & y 9 6.57 0.04 2.6 1.8 0.0 x & y
31 21.33 0.04 0.6 5.3 0.0 y 34 25.23 0.04 0.1 2.4 0.0 y 39 27.30 0.04 0.1 2.9 0.0 y
![Page 39: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/39.jpg)
39© 2006 Electric Power Research Institute, Inc. All rights reserved.
Important Modes – Top of ASB
Contributions to Phi*Gamma,Top of ASB-z
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
0 5 10 15 20 25 30 35 40 45 50
Mode Number
Ph
i*G
amm
a
Effect of Fdn-x
Effect of Fdn-y
Effect of Fdn-z
![Page 40: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/40.jpg)
40© 2006 Electric Power Research Institute, Inc. All rights reserved.
Important Modes – Top of ASB
Top of ASB-z Modal Mass as Percent of Total
Mode No Frequency
(Hz) Damping
x y z Fnd
Direction
13 9.85 0.04 0.0 0.0 25.3 z 30 21.07 0.04 0.0 0.0 18.9 z 47 33.02 0.04 0.0 0.0 9.6 z 78 54.49 0.04 0.0 0.0 4.1 z 83 57.60 0.04 0.0 0.0 0.3 z
![Page 41: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/41.jpg)
41© 2006 Electric Power Research Institute, Inc. All rights reserved.
Important Modes – Top of SCV
Contributions to Phi*Gamma,Top of SCV-x
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
0 5 10 15 20 25 30 35 40 45 50
Mode Number
Ph
i*G
amm
a
Effect of Fdn-x
Effect of Fdn-y
Effect of Fdn-z
![Page 42: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/42.jpg)
42© 2006 Electric Power Research Institute, Inc. All rights reserved.
Important Modes – Top of SCV
Top of SCV-x Modal Mass as Percent of Total
Mode No Frequency
(Hz) Damping
x y z Fnd
Direction
2 3.21 0.04 20.1 0.0 0.0 x 5 5.46 0.04 3.1 0.0 0.0 x
11 9.49 0.04 1.3 18.8 0.0 x 12 9.57 0.04 1.2 1.9 0.0 x & y 14 10.05 0.04 15.5 0.4 0.0 x 26 18.65 0.04 0.6 1.6 0.0 x & y 27 18.72 0.04 1.8 0.2 0.0 x & y 28 19.77 0.04 2.2 0.3 0.0 x 29 20.55 0.04 3.2 0.3 0.0 x 41 29.33 0.04 6.9 0.4 0.0 x 56 36.41 0.04 0.4 0.1 0.0 x 58 36.94 0.04 1.3 0.1 0.0 x & y
![Page 43: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/43.jpg)
43© 2006 Electric Power Research Institute, Inc. All rights reserved.
Important Modes – Top of SCV
Contributions to Phi*Gamma,Top of SCV-y
0.0
0.5
1.0
1.5
2.0
2.5
0 5 10 15 20 25 30 35 40 45 50
Mode Number
Ph
i*G
amm
a
Effect of Fdn-x
Effect of Fdn-y
Effect of Fdn-z
![Page 44: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/44.jpg)
44© 2006 Electric Power Research Institute, Inc. All rights reserved.
Important Modes – Top of SCV
Top of SCV-y Modal Mass as Percent of Total
Mode No Frequency
(Hz) Damping
x y z Fnd
Direction
1 3.00 0.04 0.0 21.6 0.0 y 4 4.96 0.04 0.1 0.0 0.0 y 8 6.54 0.04 3.3 2.0 0.0 x & y 9 6.57 0.04 2.6 1.8 0.0 x & y
11 9.49 0.04 1.3 18.8 0.0 y 26 18.65 0.04 0.6 1.6 0.0 x & y 27 18.72 0.04 1.8 0.2 0.0 x 31 21.33 0.04 0.6 5.3 0.0 y 51 34.15 0.04 0.4 1.5 0.0 y 54 35.84 0.04 0.3 0.0 0.0 x 55 35.95 0.04 0.1 0.2 0.0 y
![Page 45: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/45.jpg)
45© 2006 Electric Power Research Institute, Inc. All rights reserved.
Important Modes – Top of SCV
Contributions to Phi*Gamma,Top of SCV-z
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
0 5 10 15 20 25 30 35 40 45 50
M o d e N umber
Effect of Fdn-x
Effect of Fdn-y
Effect of Fdn-z
![Page 46: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/46.jpg)
46© 2006 Electric Power Research Institute, Inc. All rights reserved.
Important Modes – Top of SCV
Top of SCV-z Modal Mass as Percent of Total
Mode No Frequency
(Hz) Damping
x y z Fnd
Direction
23 16.00 0.04 0.0 0.0 4.4 z 30 21.07 0.04 0.0 0.0 18.9 z 38 26.55 0.04 0.0 0.0 0.3 z 47 33.02 0.04 0.0 0.0 9.6 z 78 54.49 0.04 0.0 0.0 4.1 z
![Page 47: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/47.jpg)
47© 2006 Electric Power Research Institute, Inc. All rights reserved.
Important Modes – Top of CIS
Contributions to Phi*Gamma,Top of CIS
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
0 5 10 15 20 25 30 35 40 45 50
Mode Number
Ph
i*G
amm
a
Effect of Fdn-x
Effect of Fdn-y
Effect of Fdn-z
![Page 48: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/48.jpg)
48© 2006 Electric Power Research Institute, Inc. All rights reserved.
Important Modes – Top of CIS
Top of CIS-x Modal Mass as Percent of Total
Mode No Frequency
(Hz) Damping
x y z Fnd
Direction
14 10.05 0.04 15.5 0.4 0.0 x 15 11.56 0.04 0.2 2.4 0.0 y 17 12.96 0.04 5.3 0.4 0.0 x & y 18 13.83 0.04 3.6 0.3 0.0 x 20 14.71 0.04 0.2 3.3 0.0 x & y 21 15.21 0.04 0.6 1.4 0.0 x & y 22 15.81 0.04 2.5 0.3 0.0 x 26 18.65 0.04 0.6 1.6 0.0 y 27 18.72 0.04 1.8 0.2 0.0 x 28 19.77 0.04 2.2 0.3 0.0 x & y 31 21.33 0.04 0.6 5.3 0.0 y 32 21.74 0.04 0.2 2.5 0.0 y 33 23.11 0.04 1.7 0.3 0.0 x 41 29.33 0.04 6.9 0.4 0.0 x 52 35.40 0.04 0.2 0.1 0.0 x 54 35.84 0.04 0.3 0.0 0.0 x 58 36.94 0.04 1.3 0.1 0.0 x 93 65.51 0.04 1.0 0.0 0.0 x
![Page 49: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/49.jpg)
49© 2006 Electric Power Research Institute, Inc. All rights reserved.
Important Modes – Top of CIS
Contributions to Phi*Gamma,Top of CIS-y
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
0 5 10 15 20 25 30 35 40 45 50
Mode Number
Ph
i*G
amm
a
Effect of Fdn-x
Effect of Fdn-y
Effect of Fdn-z
![Page 50: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/50.jpg)
50© 2006 Electric Power Research Institute, Inc. All rights reserved.
Important Modes – Top of CIS
Top of CIS-y Modal Mass as Percent of Total
Mode No Frequency
(Hz) Damping
x y z Fnd
Direction
11 9.49 0.04 1.3 18.8 0.0 y 15 11.56 0.04 0.2 2.4 0.0 x & y 17 12.96 0.04 5.3 0.4 0.0 x 19 14.37 0.04 1.0 1.4 0.0 y 20 14.71 0.04 0.2 3.3 0.0 y 22 15.81 0.04 2.5 0.3 0.0 x & y 24 16.33 0.04 0.1 0.3 0.0 y 27 18.72 0.04 1.8 0.2 0.0 x 28 19.77 0.04 2.2 0.3 0.0 x & y 29 20.55 0.04 3.2 0.3 0.0 x 31 21.33 0.04 0.6 5.3 0.0 y 32 21.74 0.04 0.2 2.5 0.0 y 41 29.33 0.04 6.9 0.4 0.0 x 51 34.15 0.04 0.4 1.5 0.0 y 54 35.84 0.04 0.3 0.0 0.0 x 55 35.95 0.04 0.1 0.2 0.0 y 58 36.94 0.04 1.3 0.1 0.0 x
![Page 51: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/51.jpg)
51© 2006 Electric Power Research Institute, Inc. All rights reserved.
Important Modes – Top of CIS
• Maximum contribution from Mode 61 – f=41.4 Hz
Contributions to Phi*Gamma,Top of CIS-z
0.0
0.5
1.0
1.5
2.0
2.5
0 5 10 15 20 25 30 35 40 45 50
Mode Number
Ph
i*G
amm
a
Effect of Fdn-x
Effect of Fdn-y
Effect of Fdn-z
![Page 52: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/52.jpg)
52© 2006 Electric Power Research Institute, Inc. All rights reserved.
Important Modes – Top of CIS
Top of CIS-z Modal Mass as Percent of Total
Mode No Frequency
(Hz) Damping
x y z Fnd
Direction
62 41.41 0.04 0.0 0.0 14.5 z 78 54.49 0.04 0.0 0.0 4.1 z 98 67.16 0.04 0.0 0.0 8.6 z
119 90.48 0.04 0.0 0.0 0.6 z
![Page 53: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/53.jpg)
53© 2006 Electric Power Research Institute, Inc. All rights reserved.
Identification of Important Modes for Simplified Modeling and Behavior Insight
• Structure model is very complex
– Coupling of the three sticks through their interconnections
– Natural torsion due to offsets horizontally of masses from shear centers for ASB and CIS introduces additional coupling
• Simplified analysis could use Phase 1 model with no natural torsion offsets and the three sticks colocated on z-axis
![Page 54: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/54.jpg)
54© 2006 Electric Power Research Institute, Inc. All rights reserved.
Validation of CLASSIinco
![Page 55: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/55.jpg)
55© 2006 Electric Power Research Institute, Inc. All rights reserved.
Validation of CLASSIinco
• Objective: Benchmark the approach and implementation of CLASSIinco with published literature
• Rigid, massless foundations on a visco-elastic half-space
– Kinematic interaction
– Incoherency transfer functions (CLASSI scattering functions)
• Circular disk of radius 84.63 ft (Area = 22,500 ft*ft)
– Luco and Mita (1987)
– Veletsos and Prasad (1989)
• Square foundation 150 ft on a side
– Luco and Wong (1986)
![Page 56: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/56.jpg)
56© 2006 Electric Power Research Institute, Inc. All rights reserved.
Validation of CLASSIinco: Key Parameters
• Visco-elastic half-space
– Shear Wave Velocity, Vs = 6300 ft/sec = 1920.24 m/sec
– Mass Density, ρ = .004969 k-sec2/ft4
– Poisson's Ratio, ν = 0.33
– Damping, ξ = 0.01
![Page 57: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/57.jpg)
57© 2006 Electric Power Research Institute, Inc. All rights reserved.
Coherency Ground Motion Function
• Coherency ground motion function (vertically incident waves) Γ(|r1 - r2|,ω) = exp[ -(γω|r1 - r2|/Vs)**2]
where |r1 - r2| is the distance between points on the foundation
(subregion centroids)γ is a dimensionless incoherence parameter,
ω is the angular frequency (radians/sec), Vs is the representative shear wave velocity of the soil profile
• CLASSIinco was modified to include the Luco and Wong representation of the coherency ground motion
• Values of γ = 0.1, 0.2, 0.3, 0.4, and 0.5 were benchmarked • Luco and Wong provide the following guidance
Vs * 2 x 10-4 sec/m ≤ γ ≤ Vs * 3 x 10-4 sec/m γ = 0.5 approximates this recommendation for Vs = 1920 m/sec
![Page 58: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/58.jpg)
58© 2006 Electric Power Research Institute, Inc. All rights reserved.
Coherency Ground Motion Function: Abrahamson vs. Luco and Wong (γ = 0.5)
γPW(f,z)
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
1.1
0 10 20 30 40 50Frequency (Hz)
Gam
ma
Abrahamson, z=10m
Abrahamson, z=20m
Abrahamson, z=50m
Abrahamson, z=100m
Luco & Mita (1987), z=10m
Luco & Mita (1987), z=20m
Luco & Mita (1987), z=50m
Luco & Mita (1987), z=100m
![Page 59: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/59.jpg)
59© 2006 Electric Power Research Institute, Inc. All rights reserved.
Circular Disk
• Luco and Mita (1987)
– Solution in terms of Bessel functions
– Horizontal and induced torsion
– Vertical and induced rocking
– Results plotted vs. dimensionless frequency a0
• Veletsos and Prasad (1989)
– Reduced the number of independent variables
– Horizontal and induced torsion plotted vs. γ * a0
Frequency (Hz) a0 1020253050
0.844041231.688082452.110103072.532123684.22020613
![Page 60: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/60.jpg)
60© 2006 Electric Power Research Institute, Inc. All rights reserved.
Circular Disk: CLASSIinco Discretization
![Page 61: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/61.jpg)
61© 2006 Electric Power Research Institute, Inc. All rights reserved.
CLASSIinco vs. Luco and Mita (1987): Horizontal ITF
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0
Dimensionless Frequency a0
Sc
atte
rin
g |
S11
| (ft
/ft)
CLASSI, g=0.1 Luco & Mita, g=0.1
CLASSI, g=0.2 Luco & Mita, g=0.2
CLASSI, g=0.3 Luco & Mita, g=0.3
CLASSI, g=0.4 Luco & Mita, g=0.4
CLASSI, g=0.5 Luco & Mita, g=0.5
![Page 62: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/62.jpg)
62© 2006 Electric Power Research Institute, Inc. All rights reserved.
CLASSIinco vs. Luco and Mita (1987): Induced Torsion ITF
0.00
0.05
0.10
0.15
0.20
0.25
0.30
0.35
0.40
0.45
0.50
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0
Dimensionless Frequency a0
Sc
att
erin
g |S
61|
(ft/
ft)
CLASSI, g=0.1 Luco & Mita, g=0.1
CLASSI, g=0.2 Luco & Mita, g=0.2
CLASSI, g=0.3 Luco & Mita, g=0.3
CLASSI, g=0.4 Luco & Mita, g=0.4
CLASSI, g=0.5 Luco & Mita, g=0.5
![Page 63: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/63.jpg)
63© 2006 Electric Power Research Institute, Inc. All rights reserved.
CLASSIinco vs. Luco and Mita (1987): Vertical ITF
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0
Dimensionless Frequency a0
Sc
att
erin
g S
|33
| (f
t/ft
)
CLASSI, g=0.1 Luco & Mita, g=0.1
CLASSI, g=0.2 Luco & Mita, g=0.2
CLASSI, g=0.3 Luco & Mita, g=0.3
CLASSI, g=0.4 Luco & Mita, g=0.4
CLASSI, g=0.5 Luco & Mita, g=0.5
![Page 64: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/64.jpg)
64© 2006 Electric Power Research Institute, Inc. All rights reserved.
CLASSIinco vs. Luco and Mita (1987): Induced Rocking ITF
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0
Dimensionless Frequency a0
Sca
tte
rin
g |S
43| (
ft/f
t)
CLASSI, g=0.1 Luco & Mita, g=0.1
CLASSI, g=0.2 Luco & Mita, g=0.2
CLASSI, g=0.3 Luco & Mita, g=0.3
CLASSI, g=0.4 Luco & Mita, g=0.4
CLASSI, g=0.5 Luco & Mita, g=0.5
![Page 65: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/65.jpg)
65© 2006 Electric Power Research Institute, Inc. All rights reserved.
CLASSIinco vs. Veletsos and Prasad (1989) (γ = 0.5): Horizontal ITF
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
0.0 1.0 2.0 3.0 4.0 5.0
Dimensionless Frequency ã0 = a0*γ
Sc
atte
rin
g |
S11
| (ft
/ft)
CLASSI, g = 0.5
Veletsos & Prasad, Eqn (9a), g=0.5
![Page 66: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/66.jpg)
66© 2006 Electric Power Research Institute, Inc. All rights reserved.
CLASSIinco vs. Veletsos and Prasad (1989) (γ = 0.5): Induced Torsion ITF
0.00
0.05
0.10
0.15
0.20
0.25
0.30
0.35
0.40
0.45
0.50
0.0 1.0 2.0 3.0 4.0 5.0
Dimensionless Frequency ã0 = a0*γ
Sc
att
eri
ng
|S
61|
(ft/
ft)
CLASSI, g = 0.5
Veletsos & Prasad, Eqn (9b), g=0.5
![Page 67: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/67.jpg)
67© 2006 Electric Power Research Institute, Inc. All rights reserved.
Square Foundation: CLASSIinco Discretization
![Page 68: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/68.jpg)
68© 2006 Electric Power Research Institute, Inc. All rights reserved.
CLASSIinco vs. Luco and Wong (1986): Horizontal ITF
0.00
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0.90
1.00
0.0 1.0 2.0 3.0 4.0 5.0
Dimensionless Frequency a0
Sca
tter
ing
S11
(ft
/ft)
CLASSI, g = 0.1 Luco & Wong, g=0.1
CLASSI, g = 0.2 Luco & Wong, g=0.2
CLASSI, g = 0.3 Luco & Wong, g=0.3
CLASSI, g = 0.4 Luco & Wong, g=0.4
CLASSI, g = 0.5 Luco & Wong, g=0.5
![Page 69: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/69.jpg)
69© 2006 Electric Power Research Institute, Inc. All rights reserved.
CLASSIinco vs. Luco and Wong (1986): Induced Torsion ITF
0.00
0.05
0.10
0.15
0.20
0.25
0.30
0.35
0.40
0.45
0.50
0.0 1.0 2.0 3.0 4.0 5.0
Dimensionless Frequency a0
Sca
tte
rin
g S
61 (
ft/f
t)
CLASSI, g = 0.1 Luco & Wong, g=0.1
CLASSI, g = 0.2 Luco & Wong, g=0.2
CLASSI, g = 0.3 Luco & Wong, g=0.3
CLASSI, g = 0.4 Luco & Wong, g=0.4
CLASSI, g = 0.5 Luco & Wong, g=0.5
![Page 70: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/70.jpg)
70© 2006 Electric Power Research Institute, Inc. All rights reserved.
CLASSIinco vs. Luco and Wong (1986): Vertical ITF
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
0.0 1.0 2.0 3.0 4.0 5.0
Dimensionless Frequency a0
Sc
att
eri
ng
S3
3 (
ft/f
t)
CLASSI, g = 0.1 Luco & Wong, g=0.1
CLASSI, g = 0.2 Luco & Wong, g=0.2
CLASSI, g = 0.3 Luco & Wong, g=0.3
CLASSI, g = 0.4 Luco & Wong, g=0.4
CLASSI, g = 0.5 Luco & Wong, g=0.5
![Page 71: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/71.jpg)
71© 2006 Electric Power Research Institute, Inc. All rights reserved.
CLASSIinco vs. Luco and Wong (1986): Induced Rocking ITF
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
0.0 1.0 2.0 3.0 4.0 5.0
Dimensionless Frequency a0
Sc
atte
rin
g S
43
(ft
/ft)
CLASSI, g = 0.1 Luco & Wong, g=0.1
CLASSI, g = 0.2 Luco & Wong, g=0.2
CLASSI, g = 0.3 Luco & Wong, g=0.3
CLASSI, g = 0.4 Luco & Wong, g=0.4
CLASSI, g = 0.5 Luco & Wong, g=0.5
![Page 72: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/72.jpg)
72© 2006 Electric Power Research Institute, Inc. All rights reserved.
Validation of CLASSIinco
• Benchmark with published literature validates CLASSIinco approach and implementation
![Page 73: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/73.jpg)
73© 2006 Electric Power Research Institute, Inc. All rights reserved.
Validation of SASSI with Incoherence
![Page 74: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/74.jpg)
74© 2006 Electric Power Research Institute, Inc. All rights reserved.
Validation of SASSI with Incoherence
• Close agreement between CLASSI & SASSI is demonstrated in Appendix C of EPRI No. 1013504
– Rigid massless foundation transfer functions and response spectra
– AP1000 stick model on a rigid foundation
• SASSI evaluation of incoherency-induced rotations on rigid massless foundations (Chapter 4)
• SASSI evaluation of incoherency-induced rotations on the AP1000 stick model with offsets & outriggers (Ch. 5)
![Page 75: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/75.jpg)
75© 2006 Electric Power Research Institute, Inc. All rights reserved.
CLASSI-SASSI Comparison from App. C
CLASSI-SASSI Comparison150 ft Square Foundation on Rock Halfspace
0.000
0.100
0.200
0.300
0.400
0.500
0.600
0.700
0.800
0.900
1.000
0 5 10 15 20 25 30 35 40 45 50
Frequency (Hz)
Inco
he
ren
cy
Tra
nsf
er
Fu
nc
tion
CLASSI-H CLASSI-V SASSI-H SASSI-V
![Page 76: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/76.jpg)
76© 2006 Electric Power Research Institute, Inc. All rights reserved.
CLASSI-SASSI Comparison from App. C
5% Damped Horizontal Spectra - 150 ft sq. Fdn on Rock Halfspace
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
0.1 1.0 10.0 100.0Frequency (Hz)
Sp
ectr
al A
ccel
erat
ion
(g
)
Free Field Input CLASSI - no wv psg SASSI- no wv psg
![Page 77: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/77.jpg)
77© 2006 Electric Power Research Institute, Inc. All rights reserved.
CLASSI-SASSI Comparison from App. C
5% Damped AP1000 Top of ASB - YY Direction
0.0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
0.1 1.0 10.0 100.0
Frequency (Hz)
Sp
ect
ral A
ccel
era
tio
n (
g)
CLASSI-FB-COH-Y Bechtel SASSI-HR-Y ACS SASSI HR-Y
![Page 78: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/78.jpg)
78© 2006 Electric Power Research Institute, Inc. All rights reserved.
CLASSI-SASSI Comparison from App. C
5% Damped AP1000 Top of ASB - YY Direction
0.0
1.0
2.0
3.0
4.0
5.0
6.0
0.1 1.0 10.0 100.0
Frequency (Hz)
Sp
ect
ral
Acc
ele
rati
on
(g
)
Bechtel SASSI-INCOH-Y CLASSI-INCOH-Y ACS SASSI INCOH-Y
![Page 79: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/79.jpg)
79© 2006 Electric Power Research Institute, Inc. All rights reserved.
CLASSI-SASSI Comparison from App. C
5% Damped AP1000 Top of SCV - YY Direction
0.0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
11.0
12.0
13.0
14.0
0.1 1.0 10.0 100.0
Frequency (Hz)
Sp
ectr
al A
cce
lera
tio
n (
g)
CLASSI-FB-COH-Y Bechtel SASSI-HR-Y ACS SASSI HR-Y
![Page 80: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/80.jpg)
80© 2006 Electric Power Research Institute, Inc. All rights reserved.
CLASSI-SASSI Comparison from App. C
5% Damped AP1000 Top of SCV - YY Direction
0.0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
11.0
12.0
0.1 1.0 10.0 100.0
Frequency (Hz)
Sp
ectr
al A
cce
lera
tio
n (
g)
Bechtel SASSI-INCOH-Y CLASSI-INCOH-Y ACS SASSI INCOH-Y
![Page 81: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/81.jpg)
81© 2006 Electric Power Research Institute, Inc. All rights reserved.
CLASSI-SASSI Comparison from App. C
5% Damped AP1000 Top of CIS - ZZ Direction
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
18.0
20.0
22.0
24.0
0.1 1.0 10.0 100.0
Frequency (Hz)
Sp
ect
ral
Acc
ele
rati
on
(g
)
CLASSI-FB-COH-Z Bechtel SASSI-HR-Z ACS SASSI HR-Z
![Page 82: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/82.jpg)
82© 2006 Electric Power Research Institute, Inc. All rights reserved.
CLASSI-SASSI Comparison from App. C
5% Damped AP1000 Top of CIS - ZZ Direction
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
0.1 1.0 10.0 100.0
Frequency (Hz)
Sp
ectr
al A
cce
lera
tio
n (
g)
Bechtel SASSI-INCOH-Z CLASSI-INCOH-Z ACS SASSI INCOH-Z
![Page 83: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/83.jpg)
83© 2006 Electric Power Research Institute, Inc. All rights reserved.
SASSI-CLASSI Comparison of Translations, Torsion, and Rocking
• Rigid massless foundation cases from Chapter 4
– Preliminary results presented here
– Good agreement for translation (horizontal & vertical)
– Need improvement for torsion & rocking
• Rigid massless foundation cases from CLASSIincohvalidation study
– Work is underway; no results available
• SSI Cases of AP1000 Model with offsets and outriggers from Chapter 5
– Work is underway; no results available
![Page 84: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/84.jpg)
84© 2006 Electric Power Research Institute, Inc. All rights reserved.
Horizontal Translation & TorsionTransfer Functions
Rock Site, 150x150 fdn, Horizontal & Torsion
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
0 10 20 30 40 50 60 70 80Frequency
Inco
her
ency
Tra
nsf
er F
un
ctio
n
CLASSI Horizontal Translation CLASSI Translation due to Torsion
SASSI Horizontal Translation SASSI Translation due to Torsion
![Page 85: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/85.jpg)
85© 2006 Electric Power Research Institute, Inc. All rights reserved.
Horizontal Translation & TorsionResponse Spectra
Horizontal and Torsion, Response Spectra, 5% DampingRock, 150 ft x 150 ft, H1 Input
0.00
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0.90
0.1 1 10 100Frequency (Hz)
Sp
ec
tra
l A
cc
ele
rati
on
(g
)
CLASSI Foundation Translation-H1 CLASSI Foundation Edge Translation due to Torsion
SASSI Foundation Translation-H1 SASSI Foundation Edge Translation due to Torsion
![Page 86: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/86.jpg)
86© 2006 Electric Power Research Institute, Inc. All rights reserved.
Vertical Translation & RockingTransfer Functions
Rock Site, 150x150 fdn, Vertical & Rocking
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
0 10 20 30 40 50 60 70 80
Frequency
Inco
her
ency
Tra
nsf
er F
un
ctio
n
CLASSI Vertical Translation CLASSI Translation due to Rocking
SASSI Vertical Translation SASSI Translation due to Rocking
![Page 87: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/87.jpg)
87© 2006 Electric Power Research Institute, Inc. All rights reserved.
Vertical Translation & RockingResponse Spectra
Vertical and Rocking, Response Spectra, 5% DampingRock, 150 ft x 150 ft, Vertical Input
0.00
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.1 1 10 100Frequency (Hz)
Sp
ec
tra
l Ac
ce
lera
tio
n (
g)
CLASSI Foundation Translation-V CLASSI Foundation Edge Translation due to Rocking
SASSI Foundatin Translation-V SASSI Foundation Edge Translation due to Rocking
![Page 88: New Plant Seismic Issues Resolution Program – …New Plant Seismic Program Task S2.1(a) • New Report – “Effect of Seismic Wave Incoherence on Foundation and Building Response”](https://reader034.vdocuments.us/reader034/viewer/2022042416/5f31bca92335d5366a0245b3/html5/thumbnails/88.jpg)
88© 2006 Electric Power Research Institute, Inc. All rights reserved.
SASSI-CLASSI Comparison of Translations, Torsion, and Rocking
• Validation package will include cases from Chs. 4 & 5 and CLASSIincoh validation study with comparisons to published result
• Examining mesh refinement and foundation stiffness to improve comparison for rotations before completing the validation