new multimeter p/n: bmmtrms13 features & benefits • auto power off after 15’ w/o use •...
TRANSCRIPT
New Multimeter P/N: BMMTRMS1
1
Multimeter
2
Applications: Precise and reliable the Bahco BMMTRMS1 Digital Multimeter is the perfect solution for user looking for a tester easy and safe to use when measuring voltage, amperage, frequency, resistance, capacitance, continuity, polarity,….., as well as temperature. Usage in many segments such as :
• Automotive • Industries • Building and construction
3
Features & Benefits
• Auto power off after 15’ w/o use
• 6,000 counts high LCD resolution display
• USB connexion to PC
• Backlight function
• Auto ranging mode i.e. no need to adjust manually any ranges • AC and DC measurement up to
1,000V • Class 600V-CATIV and 1,000V-CATIII
• Temperature measurement from -55C° to + 1,000C°
• Inner battery level indicator
• True RMS feature giving precise AC measurement • NCV (Non Contact Voltage) function
which allows to detect AC voltage without contact • Fuses protection
4
Thanks to the USB cable the multimeter is connectable on Windows PC. PC link software can be
loaded to the PC from the USB memory stick.
Features & Benefits
Accessories included
5
1. Multimeter bag with multimeter strap holder 2. Needle test silicon probe leads set 1m long : Cat III 1000V, 10A 3. Alligator Clips test probe leads sets spring-loaded copper clips with a wide 12.7 mm (0.5 inch) jaw
opening and serrated teeth 1m long: Cat III 1000V, 10A 4. T° sensor probe lead 1m long 5. Multimeter PC Connectivity USB Cable 1.2m long 6. User manual booklet in English-French-Spanish-Swedish-Turkish-Russian 7. USB Memory stick loaded with PC Link connectivity software and user manual in the following 12
languages: English-French-Spanish-Swedish-Turkish-Russian-Portugese-Italian-Greek-Sloven-Czek-Polish 8. Calibration report 9. 1 battery 6F22(9V)
❸ ❹ ❷ ❶ ❻ ❺ ❼ ❽ ❾
6
Specifications Specifications
Display: 6,000 counts
USB port connect to PC √
True RMS Measurement √
NCV function √
Relative measurement √
Auto power-off √
Data hold √
Backlight √
Auto/manual range √
Polarity indication √
Diode test √
Continuity test √
Low battery power indication √
DC Voltage: 600mV ±0.5%, 6V/60V/600V ±0,8%, 1000V ±1,0%
AC Voltage: 600mV/6V/600V ±1,0%, 1000V ±1,5%
CAT Rating: 1000V CATIII - 600V CATIV
DC Current: 600uA/6mA/60mA/600mA6A/10A ±1,5%
AC Current: 600uA/6mA/60mA/600mA ±1,5%, 6A/10A ±3,0%
Resistance: 600Ω/6KΩ/60KΩ/600KΩ/6MΩ ±0,5%, 60MΩ ±1,5%
Capacitance: 6nF ±3,0%, 600nF/6uF/60uF/300uF ±5,0%
Logic Frequency: 10Hz~1MHz ±(0,1%+3)
Linear Frequency: 10Hz~10KHz ±(0,05%+8)
Duty cycle: 1%~99%
Temperature: -55°c~1000°c ±(2%+2)
Fuses protection: 0,63A/1000Vx1 for µA and mA ranges & 10A/1000Vx1 for 10A range
Power: Battery 6F22(9V)x1 included
In the box:
User manual booklet printed in 6 languages:
• English • French • Spanish • Swedish • Turkish • Russian
In the USB memory stick:
• User manual in pdf version loaded in the USB memory stick in 12 languages:
• English • French • Spanish • Swedish • Turkish • Russian
7
User manual
• Portuguese • Italian • Greek • Slovene • Czech • Polish
CE certified according to Directive(CE):2004/108/EC Standard (EMC): • ET09121138-EMC • EN61326-1:2006 • EN61326-2-2:2006 Directive(CE): 2006/95/EC Standard (LVD): • ET09121139-LVD • EN 61010-1 :2001 • EN:61010-031:2002+A1:2
Third party certified (TÜV)
Certification
8
9
Calibration
Each and every multimeter is tested
and calibrated.
Test report is supplied with the
device.
Packaging
10
11
ASC supporting documentation
Each and every spares will be
available at the same time with
the first batch of the
multimeter. Exploded view
already loaded in Extranet.
12
Annexes
What NCV means?
Non Contact Voltage.
Thanks to this function on board the BMMTRMS1 can detect the presence of AC voltage without touching wires or electrodes
13
Annexes
Overvoltage
category In brief Examples
CAT I Electronic
• Protected electronic equipment.
• Equipment connected to (source) circuits in which measures are taken to limit transient overvoltage
to an appropriately low level.
• Any high-voltage, low-energy source derived from a high winding resistance transformer, such as
the high-voltage section of a copier.
CAT II Single-phase receptacle connected loads
• Appliance, portable tools, and other household and similar loads.
• Outlet and long branch circuits.
• Outlets at more than 10 meters (30 feet) from CAT III source.
• Outlets at more that 20 meters (60 feet) from CAT IV source.
CAT III Three-phase distribution, including single-
phase commercial lighting
• Equipment in fixed installations, such as switchgear and polyphase motors.
• Bus and feeder in industrial plants.
• Feeders and short branch circuits, distribution panel devices.
• Lighting systems in larger buildings.
• Appliance outlets with short connections to service entrance.
CAT IV Three-phase at utility connection, any
outdoor conductors
• Refers to the “origin of installation”; i.e., where low-voltage connection is made to utility power.
• Electricity meters, primary overcurrent protection equipment.
• Outside and service entrance, service drop from pole to building, run between meter and panel.
• Overhead line to detached building, underground line to well pump.
What CAT III and CAT IV mean?
Electrician professional corporations recommend to their members CAT IV
multimeters for safety.
14
Annexes
What TRMS means?
True Root Mean Square.
The true RMS value is proportional to the square-root of the average of the square of the curve. This means that True RMS is measuring the actual sine wave and not assuming the shape and filling in the blanks as is the case with the peak averaging method. This is a more complex calculation and it is more accurate.
The end result is far greater accuracy and a true measurement of voltage.