Dr. M. C. Nataraja Professor Civil Engineering Department, Sri Jayachamarajendra College of Engineering, Mysore-570 006 [email protected] (ICI Outstanding Concrete Technologist of India 2013-14) I.S method of mix design IS: 10262-2009, Indian standard Concrete mix proportioning - guidelines (First revision) 1. Scope 1.1 This standard provides the guidelines for proportioning concrete mixes as per the requirements using the concrete making materials including other supplementary materials identified for this purpose. The proportioning is carried out to achieve specified characteristics at specified age, workability of fresh concrete and durability requirements. 1.2 This standard is applicable for ordinary and standard concrete grades only 2. References I.S Code No. Title 383-1970 Specifications for coarse and fine aggregate from natural sources for concrete (second revision) 456-2000 Code of practice for plain and reinforced concrete (fourth edition) 2386 (part 3) 1963 Method of test for aggregate for concrete : Part 3 specific gravity, density, voids, absorption and bulking(Second revision)

Upload: jorge-luis-arevalo-lopez

Post on 05-May-2017

240 views

Category:

Documents


5 download

TRANSCRIPT

Page 1: New Mix Design-Is 10262 to ACI Member

Dr. M. C. NatarajaProfessor

Civil Engineering Department,Sri Jayachamarajendra College of Engineering,

Mysore-570 [email protected]

(ICI Outstanding Concrete Technologist of India 2013-14)

I.S method of mix design

IS: 10262-2009, Indian standard Concrete mix proportioning - guidelines (First revision)

1. Scope

1.1 This standard provides the guidelines for proportioning concrete mixes as per the requirements using the concrete making materials including other supplementary materials identified for this purpose. The proportioning is carried out to achieve specified characteristics at specified age, workability of fresh concrete and durability requirements.

1.2 This standard is applicable for ordinary and standard concrete grades only

2. References

I.S Code No. Title383-1970 Specifications for coarse and fine aggregate from natural sources for concrete

(second revision)

456-2000 Code of practice for plain and reinforced concrete (fourth edition)2386 (part 3) 1963

Method of test for aggregate for concrete : Part 3 specific gravity, density, voids, absorption and bulking(Second revision)

3812 (part 1) 2003

Specification of pulverized fuel ash: Part 1 For use as pozzolanain cement, cement mortar and concrete (Second revision)

8112-1989 Specification for 43 grade ordinary Portland cement (first revision)9103-1999 Specification s for admixtures for concrete ( first revision)

The following standards contain provisions, which through reference in this text, constitute provisions of this standard.

3. Data for mix proportioning

3.1 The following data are required for mix proportioning of a particular grade of concrete:a) Grade designationb) Type of cementc) Maximum nominal size of aggregate (MNSA)d) Minimum cement content

Page 2: New Mix Design-Is 10262 to ACI Member

e) Maximum water cement ratiof) Workabilityg) Exposure conditions as per Table 4 and table 5 of IS: 456h) Maximum temperature of concrete at the time of placingi) Method of transporting and placingj) Early age strength requirements, if requiredk) Type of aggregatel) Maximum cement content andm) Whether an admixture shall or shall not be used and the type of admixture and he

condition of use.

3.2 Target strength for mix proportioning

In order that not more than the specified proportioning of test results are likely to fall below the characteristic strength, the concrete mix has to be proportioned for higher target mean compressive strength f’ck. The margin over characteristic strength is given by the following relation

F’ck = fck + 1.65 s

Where,F’ck = target mean compressive strength at28 days in N/mm2,Fck= characteristic compressive strength at28 days in N/mm2, and s= standard deviation N/mm2

3.2.1 Standard deviationThe standard deviation for each grade of concrete shall be calculated separately.

3.2.1.1 Standard deviation based on test strength of samplesa) Number of test results of samples-The total number of test strength of samples required to

constitute an acceptable record for calculation of standard deviation shall be not less than 30 attempts should be made to obtain the 30 samples 9 taken from site) as early as possible, when a mix is used for the first time

b) In case of significant changes in concrete-When significant changes are made in the production of concrete batches (for example changes in the materials used, mix proportioning, equipment or technical control), the standard deviation value shall be separately calculated for such batches of concrete.

c) Standard deviation to be brought up to date- The calculation of the standard deviation shall be brought up to date after every change of mix proportioning.

3.3.1.2 Assumed standard deviation

When sufficient test results for a particular grade of concrete are not available, the value of standard deviation given in Table 1 may be assumed in the first instance.

Page 3: New Mix Design-Is 10262 to ACI Member

Table 1 Assumed standard deviationSl. No.

(1)Grade of concrete

(2)Assumed standard deviation, N/mm2

(3)1 M10 3.52 M153 M20 4.04 M255 M30

5.06 M357 M408 M459 M5010 M55

4. Selection of mix proportions4.1 selection of water cement ratio

Different cements, supplementary cementitious materials and aggregates of different maximum size, grading, surface texture, shape and other characteristics may produce concretes of different compressive strength for the same free water cement ratio. Therefore, the relationship between strength and free water cement ratio should preferably be established for the materials actually to be used. In the absence of such data, the preliminary free water cement ratio by mass corresponding to the target strength at 28 days may be selected from the established relationship, if available. Otherwise, the water cement ratio given in Table 5 of IS:456 for respective environment exposure condition may be used as starting point.

Note: The supplementary cementitious materials, that is mineral admixtures shall also be considered in water cement ratio calculations in accordance with Table 5 of IS:456-2000.

4.1.1 The free water-cement ratio selected according to 4.1 should be checked against the limiting water cement ratio for the requirement of durability and the lower of the two values adopted.

4.2 Selection of water content

The water content of concrete is influenced by a number of factors, such as aggregate size, aggregate shape, aggregate texture, workability, water-cement ratio, cement and other supplementary cementitious material type and content, chemical admixture and environmental conditions. An increase in aggregate size, a reduction in water cement ratio and slump, and use of rounded aggregate and water reducing admixtures will reduce the water demand. On the other hand increased temperature, cement content, slump, water cement ratio, aggregate angularity and a decrease in the proportion of the coarse aggregate to fine aggregate will increase water demand.

Page 4: New Mix Design-Is 10262 to ACI Member

The quantity of maximum mixing water per unit volume fo concrete may be determined from Table 2. The water content in Table 2 is for angular coarse aggregate and for 25-50 mm slump range. The water estimate in Table 2 can be reduced by approximately 10 kg for sub angular aggregate, and 20kg for gravel with some crushed particles and 25 kg for rounded gravel to produce same workability. For the desired workability other than 25- 50 mm slump, the required water content may be established by trial or an increase by 3% for every additional 25 mm slump or alternately by use of chemical admixtures conforming to IS 9103. This illustrates the need for trial batch testing of local materials as each aggregate source is different and can influence concrete properties differently. Water reducing admixtures or super plasticizing admixtures usually decrease water content by 5- 10 percent and 20 percent and above respectively at appropriate dosages.

Table 2 Maximum water content per cubic meter of concrete for nominal maximum size of aggregate (Clauses 42, A-5 and B-5)

Sl. No.

(1)

Nominal maximum size of aggregate

mm(2)

Maximum water content,Kg

(3)123

102040

208186165

Water content corresponding to saturated and surface dry aggregate

4.3 Calculation of cementitious material content

The cement and supplementary cementitious material content per unit volume of concrete may be calculated from the free water cement ratio (see 4.1) and the quantity of water per unit volume of concrete.

The cementitious material content calculated shall b checked against the minimum content for the requirements of durability and the greater of the two values adopted. The maximum cement content shall be in accordance with IS 456

4.4 Estimation of coarse aggregate proportion

Aggregates of essentially the same nominal maximum size, type and grading will produce concrete of satisfactory workability when a given volume of coarse aggregate per unit volume of total aggregate is used. Approximate values for this aggregate volume are given in Table 3 for a water cement ratio of 0.5, which may be suitably adjusted for other water cement ratios. It can be seen that for equal workability, the volume of coarse aggregate in a unit volume of concrete is dependent only on its nominal maximum size and grading zone of fine aggregate. Differences in the amount of mortar required for workability with different aggregates, due to differences in particle shape and grading, are compensated for automatically by differences in rodded void content

Page 5: New Mix Design-Is 10262 to ACI Member

4.4.1 For more workable concrete mixes which is sometimes required to be worked around congested reinforcing steel, it may be desirable to reduce the estimated coarse aggregate content determined using Table 3 up to 10 percent. However, caution shall be exercised to assume that the resulting slump, water cement ratio and strength properties of concrete are consistent with the recommendations of IS 456 and meet project specifications requirements as applicable.

Table 3 Volume of coarse aggregate per unit volume of total aggregate for different zones of fine aggregate (Clause 4.4 and A-7)Sl. No Nominal maximum

Size of aggregate, mm

Volume of coarse aggregate per unit volume of total aggregate for different zones of fine aggregate

Zone IV Zone III Zone II Zone I

123

102040

0.500.660.75

0.480.640.73

0.460.620.71

0.440.600.69

Volumes are based on aggregates in saturated surface dry conditions

4.5 Combination of different coarse aggregate fractions

The coarse aggregate used shall conform to IS 383. Coarse aggregates of different sizes may be combined in suitable proportions so as to result in an overall grading conforming to Table 2 of IS: 383 for particular nominal maximum size of aggregate.

4.6 Estimation of fine aggregate proportion

With the completion of procedure given in 4.4, all the ingredients have been estimated except the coarse and fine aggregate content. These quantities are determined by finding out the absolute volume of cementitious materials, water and the chemical admixture; by dividing their masses by their respective specific gravity, multiplying by 1/1000 and subtracting the result of their summation from unit volume. The values so obtained are divided into coarse and fine aggregate fractions by volume in accordance with coarse aggregate proportions already determined 4.4. The coarse and fine aggregate contents are then determined by multiplying with their respective specific gravities and multiplying by 1000.

5. Trial mixes

The calculated mix proportions shall be checked by means of trial batches.

Workability of the Trial mix No. 1 shall be measured. The mix shall be carefully observed for freedom from segregation and bleeding and its finishing properties. If the measured workability of Trial mix No. 1 is different from the stipulated value, the water and/or admixture content shall be adjusted suitably. With the adjustment, the mix proportions shall be recalculated keeping the free water cement ratio as the preselected value, which will comprise trial mix No. 2. In addition two more trial mixes No.3 and No. 4 shall be made with the water content same as trial No. 2 and varying the free water cement ratio by ±10 Percent of the preselected value

Page 6: New Mix Design-Is 10262 to ACI Member

Mix No. 3 and 4 normally provides sufficient information including the relationship between compressive strength and water cement ratio, from which the mix proportions for field may be arrived. The concrete for field trials shall be produced by methods of actual concrete production.

6 Illustrative examples

Illustrative examples are presented in ANNEX A and ANNEX B for M40 concrete using cement alone and using both cement and fly ash. In both cases superplasticiser is used to get the required workability. Both concretes are for pumping purpose.

Illustrative examples on concrete mix proportioning [M40 pumpable concrete]

A-1 Design stipulations for proportioning

a) Grade designation : M40b) Type of cement : OPC 43 grade confirming to IS 8112c) Maximum nominal size of aggregates : 20 mmd) Minimum cement content : 320 kg/m3

e) Maximum water cement ratio : 0.45f) Workability : 100 mm (slump)g) Exposure condition : Severe (for reinforced concrete)h) Method of concrete placing : Pumpingi) Degree of supervision : Goodj) Type of aggregate : Crushed angular aggregatek) Maximum cement content : 450 kg/m3

l) Chemical admixture type : Superplsticiser

A-2 TEST DATA FOR MATERIALS

a) Cement used : OPC 43 grade confirming to IS 8112b) Specific gravity of cement : 3.15c) Chemical admixture : Superplasticiser conforming to IS 9103d) Specific gravity of

Coarse aggregate : 2.74Fine aggregate : 2.74

e) Water absorptionCoarse aggregate : 0.5 percentFine aggregate : 1.0 percent

f) Free (surface) moistureCoarse aggregate : Nil (absorbed moisture also nil)Fine aggregate : Nil

Page 7: New Mix Design-Is 10262 to ACI Member

g) Sieve analysisCoarse aggregate : Conforming to Table 2 of IS: 383Fine aggregate : Conforming to Zone I of IS: 383

A-3 TARGET STRENGTH FOR MIX PROPORTIONINGf’

ck = fck + 1.65 sWhere

f’ck = Target average compressive strength at 28 days,

fck = Characteristic compressive strength at 28 days, s= Standard deviationFrom Table 1 standard deviation, s = 5 N/mm2

Therefore target strength = 40 + 1.65 x 5 = 48.25 N/mm2

A-4 SELECTION OF WATER CEMENT RATIO

From Table 5 of IS:456-2000, maximum water cement ratio = 0.45Based on experience adopt water cement ratio as 0.400.4 < 0.45, hence ok

A-5 SELECTION OF WATER CONTENT

From Table-2, maximum water content = 186 liters (for 25mm – 50mm slump range and for 20 mm aggregates)

Estimated water content for 100 mm slump = 186 + 6/100 x186 = 197 litersAs superplsticiser is used, the water content can be reduced up to 20 percent and aboveBased on trials with SP water content reduction of 29 percent has been achieved.Hence the water content arrived = 19 x 0.71 =140 liters

A-6 CALCULATION OF CEMENT CONTENT

Water cement ratio = 0.40Cement content = 140/0.40 = 350 kg/m3

From Table 5 of IS: 456, minimum cement content for severe exposure condition = 320 kg/m3

350 kg/m3 > 320 kg/m3, hence OK

A-7 PROPORTION OF VOLUME OF COARSE AGGREGATE AND FINE AGGREGATE CONTENT

From Table 3, volume of coarse aggregate corresponding to 20 mm size aggregate and fine aggregate (Zone I) for water-cement ratio of 0.50 =0.60

Page 8: New Mix Design-Is 10262 to ACI Member

In the present case w/c= 0.40. The volume of coarse aggregate is required to be increased to decrease the fine aggregate content. As w/c ratio is lower by 0.10, increase the coarse aggregate volume by 0.02 ( at the rate of -/+ 0.01 for every +/- 0.05 change in water cement ratio).Therefore corrected volume of coarse aggregate for w/c of 0.40 =0.62

Note: In case the coarse aggregate is not angular, then also the volume of CA may be required to be increased suitably based on experience

For puMPable concrete these values should be reduced by 10 percentTherefore volume of coarse aggregate = 0.62 x 0.9 = 0.56Volume of fine aggregate content = 1- 0.56 = 0.44

A-8 MIX CALCULATIONS

The mix calculations per unit volume of concrete shall be as follows

a) Volume of concrete = 1 m3

b) Volume of cement =

= [350/3.15] x [1/1000] = 0.111 m3

c) Volume of water = [140/1] x [1/1000] = 0.140 m3

d) Volume of chemical admixture = [7/1.145] x [1/1000] = 0.006 m3

( SP 2%by mass of cement)

e) Volume of all in aggregates (e) =a – (b + c + d) = 1 – (0.111 + 0.140 + 0.006) = 0.743 m3

f) Volume of coarse aggregates = e x Volume of CA x specific gravity of CA= 0.743 x 0.56 x 2.74 x 1000 = 11140 kg

g) Volume of fine aggregates = e x Volume of FA x specific gravity of FA= 0.743 x 0.44 x 2.74 x 1000 = 896 kg

A-9 MIX PROPORTIONS FOR TRIAL NUMBER 1

Cement = 350 kg/m3

Water = 140 kg/m3

Page 9: New Mix Design-Is 10262 to ACI Member

Fine aggregate = 896 kg/m3

Coarse aggregates = 1140 kg/m3

Chemical admixture = 7 kg/m3

Water cement ratio = 0.40

Aggregates are assumed to be in SSD. Otherwise corrections are to be applied while calculating the water content. Necessary corrections are also required to be made in mass of aggregates.

A-10 The slump shall be measured and the water content and dosages of admixture shall be adjusted for achieving the required slump based on trials, if required. The mix proportions shall be reworked for the actual water content and checked for durability requirements.

A-11 Two more trials having variation of ± 10 percent of water cement ratio in A-10 shall be carried out keeping water content constant, and a graph between three water cement ratios and their corresponding strengths shall be plotted to work out the mix proportions for the given target strength for field trials. However, durability requirements shall be met.

Illustrative examples on concrete mix proportioning [M40 pumpable concrete with fly ash]

A-1 Design stipulations for proportioning

a) Grade designation : M40b) Type of cement : OPC 43 grade confirming to IS 8112c) Type of mineral admixture : Fly ash confirming to IS 3812

(Part-1)d) Maximum nominal size of aggregates : 20 mme) Minimum cement content : 320 kg/m3

f) Maximum water cement ratio : 0.45g) Workability : 100 mm (slump)h) Exposure condition : Severe (for reinforced concrete)i) Method of concrete placing : Pumpingj) Degree of supervision : Goodk) Type of aggregate : Crushed angular aggregatel) Maximum cement content : 450 kg/m3

m) Chemical admixture type : Superplsticiser

A-2 TEST DATA FOR MATERIALS

a. Cement used : OPC 43 grade confirming to IS 8112b. Specific gravity of cement : 3.15c. Fly ash used : Fly ash confirming to IS 3812 (Part-1)

Page 10: New Mix Design-Is 10262 to ACI Member

d. Specific gravity of fly ash : 2.2e. Chemical admixture : Superplasticiser conforming to IS 9103f. Specific gravity of

i. Coarse aggregate : 2.74ii. Fine aggregate : 2.74

g. Water absorptioni. Coarse aggregate : 0.5 percent

ii. Fine aggregate : 1.0 percenth. Free (surface) moisture

i. Coarse aggregate : Nil (absorbed moisture also nil)ii. Fine aggregate : Nil

i. Sieve analysisi. Coarse aggregate : Conforming to Table 2 of IS: 383

ii. Fine aggregate : Conforming to Zone I of IS: 383

A-3 TARGET STRENGTH FOR MIX PROPORTIONINGf’

ck = fck + 1.65 sWhere

f’ck = Target average compressive strength at 28 days,

fck = Characteristic compressive strength at 28 days, s= Standard deviationFrom Table 1 standard deviation, s = 5 N/mm2

Therefore target strength = 40 + 1.65 x 5 = 48.25 N/mm2

A-4 SELECTION OF WATER CEMENT RATIO

From Table 5 of IS:456-2000, maximum water cement ratio = 0.45Based on experience adopt water cement ratio as 0.400.4 < 0.45, hence ok

A-5 SELECTION OF WATER CONTENT

From Table-2, maximum water content = 186 liters (for 25mm – 50mm slump range and for 20 mm aggregates)

Estimated water content for 100 mm slump = 186 + 6/100 x186 = 197 litersAs superplsticiser is used, the water content can be reduced up to 20 percent and aboveBased on trials with SP water content reduction of 29 percent has been achieved.Hence the water content arrived = 19 x 0.71 =140 liters

A-6 CALCULATION OF CEMENT CONTENT

Page 11: New Mix Design-Is 10262 to ACI Member

Water cement ratio = 0.40Cement content = 140/0.40 = 350 kg/m3

From Table 5 of IS: 456, minimum cement content for severe exposure condition = 320 kg/m3

350 kg/m3 > 320 kg/m3, hence OK

For proportioning fly ash concrete, the suggested steps are;Decide the percentage of fly ash to be used based on [project requirement and quality of materialsIn certain situations increase in cementitious material content may be warranted. The decision on increase in cementitious material content and its percentage may be based on experience and trial.The example is with increase of 10% of cementitious material content

Cementitious material content 1.1 x 350 = 385 kg/m3

Water content = 140 kg/m3

Water cement ratio = 140/385 = 0.364 ≈0.40

Let us use fly as at 30 percent of cementitious material content in addition to cementFly ash = 385 x 0.3 = 115 kg/m3

Cement =385-115=270 kg/m3 (Saving of cement coMPared to previous design = 350-279 = 80 kg/m3 and fly ash utilization = 115 kg/m3)

A-7 PROPORTION OF VOLUME OF COARSE AGGREGATE AND FINE AGGREGATE CONTENT

From Table 3, volume of coarse aggregate corresponding to 20 mm size aggregate and fine aggregate (Zone I) for water-cement ratio of 0.50 =0.60In the present case w/c= 0.40. The volume of coarse aggregate is required to be increased to decrease the fine aggregate content. As w/c ratio is lower by 0.10, increase the coarse aggregate volume by 0.02 (at the rate of -/+ 0.01 for every +/- 0.05 change in water cement ratio).Therefore, corrected volume of coarse aggregate for w/c of 0.40 =0.62.

Note: In case the coarse aggregate is not angular, then also the volume of CA may be required to be increased suitably based on experience

For puMPable concrete these values should be reduced by 10 percentTherefore volume of coarse aggregate = 0.62 x 0.9 = 0.56Volume of fine aggregate content = 1- 0.56 = 0.44

A-8 MIX CALCULATIONS

Page 12: New Mix Design-Is 10262 to ACI Member

The mix calculations per unit volume of concrete shall be as follows

h) Volume of concrete = 1 m3

i) Volume of cement =

= [270/3.15] x [1/1000] = 0.086 m3

j) Volume of fly ash = [115/2.2] x [1/1000] = 0.052 m3

k) Volume of water = [140/1] x [1/1000] = 0.140 m3

l) Volume of chemical admixture = [7.7/1.145] x [1/1000] = 0.007 m3

( SP 2%by mass of cementitiousmaterial)

m) Volume of all in aggregates (e) =a – (b + c + d) = 1 – (0.086 + 0.052 + 0.140 + 0.007) = 0.715 m3

n) Volume of coarse aggregates = e x Volume of CA x specific gravity of CA= 0.715 x 0.56 x 2.74 x 1000 = 1097 kg

o) Volume of fine aggregates = e x Volume of FA x specific gravity of FA= 0.715 x 0.44 x 2.74 x 1000 = 862 kg

A-9 MIX PROPORTIONS FOR TRIAL NUMBER 1

Cement = 270 kg/m3

Fly ash = 115 kg/m3

Water = 140 kg/m3

Fine aggregate = 862 kg/m3

Coarse aggregates = 1097 kg/m3

Chemical admixture = 7.7 kg/m3

Water cement ratio = 0.364

Aggregates are assumed to be in SSD. Otherwise corrections are to be applied while calculating the water content. Necessary corrections are also required to be made in mass of aggregates.

Page 13: New Mix Design-Is 10262 to ACI Member

A-10 The slump shall be measured and the water content and dosages of admixture shall be adjusted for achieving the required slump based on trials, if required. The mix proportions shall be reworked for the actual water content and checked for durability requirements.

A-11 Two more trials having variation of ± 10 percent of water cement ratio in A-10 shall be carried out keeping water content constant, and a graph between three water cement ratios and their corresponding strengths shall be plotted to work out the mix proportions for the given target strength for field trials. However, durability requirements shall be met.

Design of M20 concrete mix as per IS:10262-2009, Concrete mix proportioning-guidelines (First revision)

A-1 Design stipulations for proportioning

i. Grade designation : M20ii. Type of cement : OPC 43 grade confirming to IS 8112

iii. Maximum nominal size of aggregates : 20 mmiv. Minimum cement content : 320 kg/m3

v. Maximum water cement ratio : 0.55vi. Workability : 75 mm (slump)

vii. Exposure condition : Mildviii. Degree of supervision : Good

ix. Type of aggregate : Crushed angular aggregatex. Maximum cement content : 450 kg/m3

xi. Chemical admixture : Not recommended

A-2 TEST DATA FOR MATERIALS

i. Cement used : OPC 43 grade confirming to IS 8112ii. Specific gravity of cement : 3.15

iii. Specific gravity of i. Coarse aggregate : 2.68

ii. Fine aggregate : 2.65iv. Water absorption

i. Coarse aggregate : 0.6 percentii. Fine aggregate : 1.0 percent

v. Free (surface) moisturei. Coarse aggregate : Nil (absorbed moisture full)

ii. Fine aggregate : Nilvi. Sieve analysis

i. Coarse aggregate : Conforming to Table 2 of IS: 383ii. Fine aggregate : Conforming to Zone I of IS: 383

Page 14: New Mix Design-Is 10262 to ACI Member

A-3 TARGET STRENGTH FOR MIX PROPORTIONINGf’

ck = fck + 1.65 sWhere

f’ck = Target average compressive strength at 28 days,

fck = Characteristic compressive strength at 28 days, s= Standard deviationFrom Table 1 standard deviation, s = 4 N/mm2

Therefore target strength = 20 + 1.65 x 4 = 26.60 N/mm2

A-4 SELECTION OF WATER CEMENT RATIO

From Table 5 of IS:456-2000, maximum water cement ratio = 0.55 (Mild exposure)Based on experience adopt water cement ratio as 0.500.5 < 0.55, hence ok

A-5 SELECTION OF WATER CONTENT

From Table-2, maximum water content = 186 liters (for 25mm – 50mm slump range and for 20 mm aggregates)

Estimated water content for 75 mm slump = 186 + 3/100 x186 = 191.6 liters

A-6 CALCULATION OF CEMENT CONTENT

Water cement ratio = 0.50Cement content = 191.6/0.5 = 383 kg/m3 >320 kg/m3(given)

From Table 5 of IS: 456, minimum cement content for mild exposure condition = 300 kg/m3

Hence OK

A-7 PROPORTION OF VOLUME OF COARSE AGGREGATE AND FINE AGGREGATE CONTENT

From Table 3, volume of coarse aggregate corresponding to 20 mm size aggregate and fine aggregate (Zone I) for water-cement ratio of 0.50 =0.60

A-8 MIX CALCULATIONS

The mix calculations per unit volume of concrete shall be as follows

a) Volume of concrete = 1 m3

Page 15: New Mix Design-Is 10262 to ACI Member

b) Volume of cement =

= [383.16/3.15] x [1/1000] = 0.122 m3

c) Volume of water = [192/1] x [1/1000] = 0.192 m3

d) Volume of all in aggregates (e) =a – (b + c) = 1 – (0.122 + 0.192) = 0.686 m3

e) Volume of coarse aggregates = e x Volume of CA x specific gravity of CA= 0.686 x 0.6 x 2.68 x 1000 = 1103 kg

f) Volume of fine aggregates = e x Volume of FA x specific gravity of FA= 0.686 x 0.4 x 2.65 x 1000 = 727 kg

A-9 MIX PROPORTIONS FOR TRIAL NUMBER 1

Cement = 383 kg/m3

Water = 191.6 kg/m3

Fine aggregate = 727 kg/m3

Coarse aggregates = 1103 kg/m3

Water cement ratio = 0.50Yield =2404.6 kg

Aggregates are assumed to be in SSD. Otherwise corrections are to be applied while calculating the water content. Necessary corrections are also required to be made in mass of aggregates.

Trial mixes:

Laboratory results: Slump and compacting factor of the above mix when tested in laboratory are 90mm and 0.93 respectively. The slump is slightly more than the required and hence the mix can be accepted without any modification to reduce slump. Six concrete cubes are cast for compression testing at 7 and 28 days. As per IS two more mixes are worked out having variation of ± 10 percent of water cement ratio, and keeping water content constant. All three mixes are presented in table and the workability results along with 7 and 28 day results are presented in table.

Details not includedDr. M. C. Nataraja