    Grounding of Electrical

    systems

  • 8/14/2019 New Microsoft PowerPoint Presentation .ppt

    2/32

    Grounded & Ungrounded Systems

  • 8/14/2019 New Microsoft PowerPoint Presentation .ppt

    3/32

    Grounded & Ungrounded Systems

  • 8/14/2019 New Microsoft PowerPoint Presentation .ppt

    4/32

    Grounding & Bonding

    Grounding Neutral of power supply unit is attached to earth

    Neutral of different utility sections is attached to

    ground

    Bonding Enclosures of two different equipments are

    attached to each other with a solid conductor to

    avoid static charge development

  • 8/14/2019 New Microsoft PowerPoint Presentation .ppt

    5/32

    Requirement of Grounding &

    Bonding

    To avoid electrocuting of living entities

    To avoid transient over voltages To direct static charges to ground

    To have an easy identification of faulty

    conditions To protect electrical equipment

  • 8/14/2019 New Microsoft PowerPoint Presentation .ppt

    6/32

    Bonding

  • 8/14/2019 New Microsoft PowerPoint Presentation .ppt

    7/32

    Methods of Grounding

  • 8/14/2019 New Microsoft PowerPoint Presentation .ppt

    8/32

    Grounding Techniques

  • 8/14/2019 New Microsoft PowerPoint Presentation .ppt

    9/32

  • 8/14/2019 New Microsoft PowerPoint Presentation .ppt

    10/32

    Ungrounded Systems

  • 8/14/2019 New Microsoft PowerPoint Presentation .ppt

    11/32

    Solid Grounding

    Neutral of the power supply is attached directly to ground

    Neutral point is held at earth potential in all conditions

    Advantages Faulty conditions could be identified easily

    No over voltages on healthy phases occur

    High safety of living entities

    Disadvantages Large values of fault current

    Possible equipment damage

  • 8/14/2019 New Microsoft PowerPoint Presentation .ppt

    12/32

    Solid Grounding

  • 8/14/2019 New Microsoft PowerPoint Presentation .ppt

    13/32

    Resistance Grounding

    Neutral of the power supply is attached to ground

    through a resistor

    Value of R should neither be very low nor very high

    Advantages Fault current magnitude is reduced

    Improves the stability of the system under faulty

    conditions

    Disadvantages

    Neutral is displaced during an earth fault

    Large amount of energy is produced in the earthing

    resistor for a fault

  • 8/14/2019 New Microsoft PowerPoint Presentation .ppt

    14/32

    Resistance Grounding

  • 8/14/2019 New Microsoft PowerPoint Presentation .ppt

    15/32

    Reactance Grounding

    A reactor is attached between neutral and

    ground

    Higher fault currents would be required forinterruption

    By adjusting the value of reactance we can

    adjust the system to operate as any scheme ofgrounding

  • 8/14/2019 New Microsoft PowerPoint Presentation .ppt

    16/32

    Reactance Grounding

  • 8/14/2019 New Microsoft PowerPoint Presentation .ppt

    17/32

    Resonant Grounding

    A variable inductance coil is used to avoidthe flow of charging current for faultconditions

    If IL=IC fault current would be almost zero Reactor is provided with tapings to avoid

    different values of charging current

    A small magnitude of fault current flowswhich is in phase with the faulty phasevoltage

  • 8/14/2019 New Microsoft PowerPoint Presentation .ppt

    18/32

    Resonant Grounding

  • 8/14/2019 New Microsoft PowerPoint Presentation .ppt

    19/32

    Voltage Transformer Earthing

    A single phase voltage transformer is used

    to make a ground connection.

    Primary is attached between neutral and

    earth

    A low resistance is attached in series with

    a relay across the Secondary

    Eliminates the condition of arcing grounds

    and transient over voltages

  • 8/14/2019 New Microsoft PowerPoint Presentation .ppt

    20/32

    Voltage Transformer Earthing

  • 8/14/2019 New Microsoft PowerPoint Presentation .ppt

    21/32

    Grounding Techniques for Delta

    Connected System

    For system sections having delta

    connections a virtual neutral is achieved to

    facilitate the protection system Grounding transformers are used to create

    this virtual neutral point

    Grounding T/F Types Zig-Zag Transformers

    Wye-Delta Transformers

  • 8/14/2019 New Microsoft PowerPoint Presentation .ppt

    22/32

    Zig-Zag Transformer

    Grounding Techniques for Delta

    Connected System

    G di T h i f D lt

  • 8/14/2019 New Microsoft PowerPoint Presentation .ppt

    23/32

    Zig-Zag Transformer

    Behavior of Zig-Zag transformer durring a ground

    fault

    Grounding Techniques for Delta

    Connected System

  • 8/14/2019 New Microsoft PowerPoint Presentation .ppt

    24/32

    Wye-Delta Transformer

    Primary is attached to the system for which

    grounding is required

    Neutral may be solidly or impedance

    grounded

    Secondary is delta connected or may be opendelta connected

    Grounding Techniques for Delta

    Connected System

  • 8/14/2019 New Microsoft PowerPoint Presentation .ppt

    25/32

    Wye-Delta Transformer In normal conditions the transformer behaves like

    an open circuited secondary and draws only a

    small magnitude of magnetizing current

    Grounding Techniques for Delta

    Connected System

  • 8/14/2019 New Microsoft PowerPoint Presentation .ppt

    26/32

    Wye-Delta Transformer Operation under ground fault conditions

    Grounding Techniques for Delta

    Connected System

  • 8/14/2019 New Microsoft PowerPoint Presentation .ppt

    27/32

    Equipment Grounding

    Equipment grounding is done to avoidelectrocuting of living entities

    Fault current could flow through ground mass or

    conductive path Usually low impedance or solid grounding is

    used to avoid potential rise at the equipmentenclosure

    For remote distances potential could developbetween different locations over the groundmass

  • 8/14/2019 New Microsoft PowerPoint Presentation .ppt

    28/32

    Equipment Grounding

  • 8/14/2019 New Microsoft PowerPoint Presentation .ppt

    29/32

    A conductive path is provided to minimizethe impedance for fault current

    Equipment Grounding

  • 8/14/2019 New Microsoft PowerPoint Presentation .ppt

    30/32

  • 8/14/2019 New Microsoft PowerPoint Presentation .ppt

    31/32

    Ground Fault Current Detection

  • 8/14/2019 New Microsoft PowerPoint Presentation .ppt

    32/32

    Grounding Connection for Surge

    Protective Equipment

    Surge arrestors are used to direct any line

    surge to ground