new innovations in cell culture
TRANSCRIPT
8/6/2019 New Innovations in Cell Culture
http://slidepdf.com/reader/full/new-innovations-in-cell-culture 1/8
New Innovationsin Cell CultureLife-changing tools to help with
every step of your research
Assisting. Accelerating. Advancing.
Multilayer CultureFlasks
Unequa led culture g rowth
Millicell ® µ-Angiogenesis
Easy-to-useAssay Kits
Superiorvisualizatio n
Revolutio nizingcell cou nting
Handheld, AutomatedCell Counter
Millicell®
HY Flasks Scepter™
4 and 8-wellCulture Slides
Si mplicity per sonified Millicell ® EZ SLIDE
8/6/2019 New Innovations in Cell Culture
http://slidepdf.com/reader/full/new-innovations-in-cell-culture 2/8
A NEW WINDOW INTOYOUR CELL CULTURES• Histogram plots of
cell populations
• Data on cell concentration,cell volume and size
• Gain quick insight into cell health
While other automated counters rely on object recognition software, manual focusing, and clumsy
loading chambers, the Scepter cell counter provides true automation without the error that
accompanies vision-based systems. With its microfabricated, precision-engineered sensor, the
Scepter cell counter does all the work and delivers accurate and reliable cell counts in less
than 20 seconds.
Truly accurate and automatic
Scepter Handheld
Automated Cell Counter
8/6/2019 New Innovations in Cell Culture
http://slidepdf.com/reader/full/new-innovations-in-cell-culture 3/8
Description Qty/Pk Catalogue No.
Scepter Handheld Automated Cell Counter 1 PHCC00000Includes: Scepter Cell Counter 1Scepter Software CD 1O-Rings 2Scepter Test Beads 1 PHCCBEADS Scepter USB Cable 1 PHCCCABLE
ACCESSORIESScepter Sensors, 60 µm 50 PHCC60050
500 PHCC60500
Universal Power Adapter 1 PHCCPOWER
Scepter O-Ring Kit, contains two O-rings and one lter cover 1 kit PHCC0CLIP
TECHNOLOGYPACKED SENSOR• Precisely counts consistent
sample volumes
• Accurately counts every cell in your sample
• Cell discrimination at sub-micronand sub-picoliter resolution
8/6/2019 New Innovations in Cell Culture
http://slidepdf.com/reader/full/new-innovations-in-cell-culture 4/8
Description No. of Layers Total Surface Area (cm 2) Qty/Pk Catalogue No.
Millicell HY Flask*§ 3 600 16 PFHYS0616
STEM CELL TESTED 5 1000 8 PFHYS1008
We can’t make your cells grow any faster, but with our asks, you’ll get substantially higher yields
with the same effort. When choosing a multilayer ask to save space and time, choose the ask
that outperforms the rest: the Millicell HY (high yield) ask.
Each Millicell HY ask is speci cally designed to provide a consistent, quality growth environment
across all layers, which translates into cell growth and yields that surpass those of other multilayer
asks. Just as importantly, the Millicell HY ask’s unique, ergonomic design makes recovering cells
easy, with convenient access to pipetting or pouring. Millicell HY asks deliver consistently high
yields of healthy cells all grown in the same homogeneous environment to ensure reproducibility.
Unequaled cell growth with
Millicell HY Flasks
Uniform culture conditionswithout media leaking orspillover between layers
Easy media removalfrom flask withergonomic caplocationStackable for more
space savings
8/6/2019 New Innovations in Cell Culture
http://slidepdf.com/reader/full/new-innovations-in-cell-culture 5/8
Use the Millicell EZ slide to culture, x, stain and view your sample all in one device. There is no need
to tediously move cover slips from your culture dish to a slide. Fix and stain right in one EZ device,
then use the breakaway tabs to effortlessly remove the chamber well and acquire your data simply
and quickly.
Break away from the tedium using effortless
Millicell EZ slides
Clear lid foreasy viewing
Description Qty/Pk Catalogue No.
Millicell EZ slide (4-well glass) 16 PEZGS0416 96 PEZGS0496Millicell EZ slide (8-well glass) 16 PEZGS0816 96 PEZGS0896
Millicell EZ Slide Microscope Slide Holder 1 PEZXMSH01
Breakaway tab sfor easy wellremoval
Chemically
resistantchamber wells
8/6/2019 New Innovations in Cell Culture
http://slidepdf.com/reader/full/new-innovations-in-cell-culture 6/8
With unprecedented optical resolution, the Millicell
µ-Angiogenesis activation and inhibition kits provide
a powerful platform for real-time monitoring of
changes in tubule formation.
Superior Visualization of Your Cells with
Millicell µ-Angiogenesis
Assay Kits
Cell Medium(50 µL) Cells
on Gel
Coverslip-likeplastic
Gel Matrix(10 µL)
Miniaturized formatreduces costs andwaste by up to 80%
*Activation Assay shown.
8/6/2019 New Innovations in Cell Culture
http://slidepdf.com/reader/full/new-innovations-in-cell-culture 7/8
Description Qty/Pk Catalogue No.
Millicell µ-Angiogenesis Inhibition Assay 1 (5 slides, 75 microwells) MMA125
Millicell µ-Angiogenesis Activation Assay 1 (5 slides, 75 microwells) MMA130
Fibrin In Vitro Angiogenesis Assay (reagents only) 1 (enough for 1 x 96-well plate) ECM630
In Vitro Angiogenesis Assay Kit (reagents only) 1 (enough for 1 x 96-well plate) ECM625
Unique slide designeliminates anyliquid meniscus andout-of-focus areas
Optimized assayconditions
Continuousmonitoring of cells
All-in-one slide usedto grow, treat, andstain cells
Compatible withmultichannel pipettes
Full well visualizationat low magni cationmeans signi cantly lesstime spent on imaging
8/6/2019 New Innovations in Cell Culture
http://slidepdf.com/reader/full/new-innovations-in-cell-culture 8/8
TO PLACE AN ORDER OR
RECEIVE TECHNICAL ASSISTANCE In the U.S. and Canada , call toll-free 1 800-Millipore (1-800-645-5476)
In Europe , please call Customer Service:
France: 0825.045.645
Spain: 901.516.645 Option 1
Germany: 01805.045.645
Italy: 848.845.645
United Kingdom: 0870.900.46.45
For other countries across Europe and the world,
please visit www.millipore.com/offices .
For Technical Service, please visit www.millipore.com/techservice .
Pore Size Funnel Capacity Receiver BottleDescription Membrane/Application (µm) (mL) (mL) Qty/Pk Catalogue No.
Steritop-GP Filter Units, Millipore Express PLUS (PES) / 0.22 150 NA 12 SCGPS01RE33 mm § fast ltration of tissue culture 250 NA 12 SCGPS02RE
STEM CELL TESTED media and buffers 500 NA 12 SCGPS05RE1000 NA 12 SCGPS10RE
Steritop-GP Filter Units, Millipore Express PLUS (PES) / 0.22 150 NA 12 SCGPT01RE45 mm fast ltration of tissue culture 250 NA 12 SCGPT02RE
media and buffers 500 NA 12 SCGPT05RE1000 NA 12 SCGPT10RE
Steri ip Filter Units Millipore Express PLUS (PES) / 0.22 50 50 50 SCGP00525fast ltration of tissue culturemedia and buffers
Steritop ® and Steriflip ® Filter UnitsSteritop bottle-top filters fit 33 mm and 45 mm openings, and Steriflip devices filter solutions from 50 mL conical tubes.
Pore Size Funnel Capacity Receiver BottleDescription Membrane/Application (µm) (mL) (mL) Qty/Pk Catalogue No.
Stericup-GP Filter Units § Millipore Express ® PLUS (PES) / 0.22 ** 150 150 12 SCGPU01RESTEM CELL TESTED fast ltration of tissue culture 250 250 12 SCGPU02RE
media and buffers 500 500 12 SCGPU05RE 500 1000 12 SCGPU10RE1000 1000 12 SCGPU11RE
Stericup-VP Filter Units Millipore Express PLUS (PES) / 0.1 250 250 12 SCVPU02RE removal of mycoplasma † 1000 1000 12 SCVPU11RE
Stericup ® Filter UnitsStericup filter devices combine a filter unit with a receiver flask and cap for processing and storage.
* Available with barcodes – please contact technical service for more information.
** 0.10 µm pore size is designed to enhance maximum ltration of tissue culture
media but it is not a guarantee of complete mycoplasma removal.§ Stem cell testing was conducted by using the device in question for culturing
mESC for ve passages, then verifying by ow cytometry that viability andpluripotency are unchanged.
ADDITIONAL PRODUCTS
www.millipore.com
Millipore, Advancing Life Science Together, Millipore Express, Millicell, Stericup, Steritop,and Steriflip are registered trademarks of Millipore Corporation.
The M mark and Scepter are trademarks of Millipore Corporation.Lit. No. PB2578EN00 Rev. - 07/10 LS-SBU-10-03242 Printed in U.S.A.© 2010 Millipore Corporation, Billerica, MA 01821 U.S.A. All rights reserved.
www.millipore.com