Case Study: Treating Manganese
in Groundwater
Merrimack Village District
Wells 7 & 8
Michael Unger, P.E. Senior Project Engineer
NHWWA/NHDES Manganese Seminar
June 1, 2016
![Page 2: New Hampshire Water Works Association - Case … › wp-content › uploads › Surface-Water...Project Overview •Iron & Manganese Treatment Facility –Capacity = 1,250 gpm (1.8](https://reader033.vdocuments.us/reader033/viewer/2022042405/5f1c46cc4078c7029a1a21b5/html5/thumbnails/2.jpg)
Well 7
• Installed 1996
• Approved for 500 gpm
or 720,000 gpd
2
![Page 3: New Hampshire Water Works Association - Case … › wp-content › uploads › Surface-Water...Project Overview •Iron & Manganese Treatment Facility –Capacity = 1,250 gpm (1.8](https://reader033.vdocuments.us/reader033/viewer/2022042405/5f1c46cc4078c7029a1a21b5/html5/thumbnails/3.jpg)
Well 8
• Installed 1999
• Approved for 750 gpm
or 1,080,000 gpd
3
![Page 4: New Hampshire Water Works Association - Case … › wp-content › uploads › Surface-Water...Project Overview •Iron & Manganese Treatment Facility –Capacity = 1,250 gpm (1.8](https://reader033.vdocuments.us/reader033/viewer/2022042405/5f1c46cc4078c7029a1a21b5/html5/thumbnails/4.jpg)
Wells 7 & 8
• Combined pumping rate of 1,250 gpm
• Represents 30% of MVD supply capacity
• Good water quality when wells put on line
• BUT Iron (Fe) & Manganese (Mn) have
increased over time with use of wells
4
![Page 5: New Hampshire Water Works Association - Case … › wp-content › uploads › Surface-Water...Project Overview •Iron & Manganese Treatment Facility –Capacity = 1,250 gpm (1.8](https://reader033.vdocuments.us/reader033/viewer/2022042405/5f1c46cc4078c7029a1a21b5/html5/thumbnails/5.jpg)
5
0
0.5
1
1.5
2
2.5
3
3.5
Jan-92 Jan-96 Jan-00 Jan-04 Jan-08 Jan-12 Jan-16
mg
/L
Sample Date
Well #7 - Iron
3 times the SMCL
Secondary MCL
![Page 6: New Hampshire Water Works Association - Case … › wp-content › uploads › Surface-Water...Project Overview •Iron & Manganese Treatment Facility –Capacity = 1,250 gpm (1.8](https://reader033.vdocuments.us/reader033/viewer/2022042405/5f1c46cc4078c7029a1a21b5/html5/thumbnails/6.jpg)
0.000
0.100
0.200
0.300
0.400
0.500
0.600
0.700
0.800
Jan-92 Jan-96 Jan-00 Jan-04 Jan-08 Jan-12 Jan-16
mg
/L
Sample Date
Well #7 - Manganese
6 Times the SMCL
6
Secondary MCL
![Page 7: New Hampshire Water Works Association - Case … › wp-content › uploads › Surface-Water...Project Overview •Iron & Manganese Treatment Facility –Capacity = 1,250 gpm (1.8](https://reader033.vdocuments.us/reader033/viewer/2022042405/5f1c46cc4078c7029a1a21b5/html5/thumbnails/7.jpg)
00.2
0.40.60.8
11.21.4
1.61.8
2
Jan-92 Jan-96 Jan-00 Jan-04 Jan-08 Jan-12 Jan-16
mg
/L
Sample Date
Well #8 - Iron
6 Times the SMCL
7
Secondary MCL
Well Offline
![Page 8: New Hampshire Water Works Association - Case … › wp-content › uploads › Surface-Water...Project Overview •Iron & Manganese Treatment Facility –Capacity = 1,250 gpm (1.8](https://reader033.vdocuments.us/reader033/viewer/2022042405/5f1c46cc4078c7029a1a21b5/html5/thumbnails/8.jpg)
0
0.05
0.1
0.15
0.2
0.25
0.3
0.35
Jan-92 Jan-96 Jan-00 Jan-04 Jan-08 Jan-12
mg
/L
Sample Date
Well #8 - Manganese
5 Times the SMCL
8
Secondary MCL
Well Offline
![Page 9: New Hampshire Water Works Association - Case … › wp-content › uploads › Surface-Water...Project Overview •Iron & Manganese Treatment Facility –Capacity = 1,250 gpm (1.8](https://reader033.vdocuments.us/reader033/viewer/2022042405/5f1c46cc4078c7029a1a21b5/html5/thumbnails/9.jpg)
Need for Project --
Wells #7 and #8 Water Quality
• Customer complaints attributable to Fe/Mn
• Fe/Mn increase distribution system
maintenance required
• Sequestration not effective
• Treatment is only reliable way to reduce
Fe/Mn at full capacity
9
![Page 10: New Hampshire Water Works Association - Case … › wp-content › uploads › Surface-Water...Project Overview •Iron & Manganese Treatment Facility –Capacity = 1,250 gpm (1.8](https://reader033.vdocuments.us/reader033/viewer/2022042405/5f1c46cc4078c7029a1a21b5/html5/thumbnails/10.jpg)
Need for Project – Supply Capacity
• Have not been able to use Well 8 since 2008
• Use Well 7 only when necessary due to
demand
– Results in customer complaints
• Puts more stress on other wells
• Demand is increasing
• Need full capacity of Wells 7 & 8 without
sacrificing water quality
10
![Page 11: New Hampshire Water Works Association - Case … › wp-content › uploads › Surface-Water...Project Overview •Iron & Manganese Treatment Facility –Capacity = 1,250 gpm (1.8](https://reader033.vdocuments.us/reader033/viewer/2022042405/5f1c46cc4078c7029a1a21b5/html5/thumbnails/11.jpg)
Supply Needed
11
*Based on 2005 through 2012 production data.
** 320 gpm capacity needed, based on a 24 hour pumping day
*** 472 gpm capacity needed, based on a 24 hour pumping day
Current
Shortfall*
Year 2030
Shortfall
MGD MGD
Annual Average
Day Demand
0 0
Summer Average
Day Demand
0 0.46**
Maximum Day
Demand
0 to 0.18 0.68***
![Page 12: New Hampshire Water Works Association - Case … › wp-content › uploads › Surface-Water...Project Overview •Iron & Manganese Treatment Facility –Capacity = 1,250 gpm (1.8](https://reader033.vdocuments.us/reader033/viewer/2022042405/5f1c46cc4078c7029a1a21b5/html5/thumbnails/12.jpg)
Water Supply Improvement
Options Evaluated
• Increase Capacity of Well #2
• Treat Well #6
• Treat Wells #7 & #8 and Blend
• New Groundwater Source
• Pennichuck Water Works (PWW)
• Manchester Water Works (MWW)
• Surface Water Treatment Plant
• Some combination
12
![Page 13: New Hampshire Water Works Association - Case … › wp-content › uploads › Surface-Water...Project Overview •Iron & Manganese Treatment Facility –Capacity = 1,250 gpm (1.8](https://reader033.vdocuments.us/reader033/viewer/2022042405/5f1c46cc4078c7029a1a21b5/html5/thumbnails/13.jpg)
Pilot Testing
13
1. Compare Greensand Plus and Pyrolusite
2. Recommend operating parameters:
• Chlorine Dose
• pH range
• Surface Loading Rates filter sizing
3. Evaluate backwash:
• Solids settling feasibility to recycle supernatant
• Backwash characteristics (physical and chemical)
• Production rates
![Page 14: New Hampshire Water Works Association - Case … › wp-content › uploads › Surface-Water...Project Overview •Iron & Manganese Treatment Facility –Capacity = 1,250 gpm (1.8](https://reader033.vdocuments.us/reader033/viewer/2022042405/5f1c46cc4078c7029a1a21b5/html5/thumbnails/14.jpg)
Pilot Testing - Conclusions
14
• Both Greensand Plus and Pyrolusite effective at Fe/Mn
removal
• Chlorine Dose 2.0 to 2.4 mg/L
• pH range 6.8 to 7.0
• Surface Loading Rates 5 to 7 gpm/sq.ft. for 24 hour run
times
• Solids settled quickly
![Page 15: New Hampshire Water Works Association - Case … › wp-content › uploads › Surface-Water...Project Overview •Iron & Manganese Treatment Facility –Capacity = 1,250 gpm (1.8](https://reader033.vdocuments.us/reader033/viewer/2022042405/5f1c46cc4078c7029a1a21b5/html5/thumbnails/15.jpg)
Project Overview
• Iron & Manganese Treatment Facility
– Capacity = 1,250 gpm (1.8 MGD)
• Full capacity of Wells 7 and 8
• Improvements to Wells 7 and 8
• Provisions for Well 6 or new well treatment in
future
15
![Page 16: New Hampshire Water Works Association - Case … › wp-content › uploads › Surface-Water...Project Overview •Iron & Manganese Treatment Facility –Capacity = 1,250 gpm (1.8](https://reader033.vdocuments.us/reader033/viewer/2022042405/5f1c46cc4078c7029a1a21b5/html5/thumbnails/16.jpg)
16
![Page 17: New Hampshire Water Works Association - Case … › wp-content › uploads › Surface-Water...Project Overview •Iron & Manganese Treatment Facility –Capacity = 1,250 gpm (1.8](https://reader033.vdocuments.us/reader033/viewer/2022042405/5f1c46cc4078c7029a1a21b5/html5/thumbnails/17.jpg)
17
WELL 7
WELL 8
FILTRATION
BUILDING
![Page 18: New Hampshire Water Works Association - Case … › wp-content › uploads › Surface-Water...Project Overview •Iron & Manganese Treatment Facility –Capacity = 1,250 gpm (1.8](https://reader033.vdocuments.us/reader033/viewer/2022042405/5f1c46cc4078c7029a1a21b5/html5/thumbnails/18.jpg)
18
![Page 19: New Hampshire Water Works Association - Case … › wp-content › uploads › Surface-Water...Project Overview •Iron & Manganese Treatment Facility –Capacity = 1,250 gpm (1.8](https://reader033.vdocuments.us/reader033/viewer/2022042405/5f1c46cc4078c7029a1a21b5/html5/thumbnails/19.jpg)
19
![Page 20: New Hampshire Water Works Association - Case … › wp-content › uploads › Surface-Water...Project Overview •Iron & Manganese Treatment Facility –Capacity = 1,250 gpm (1.8](https://reader033.vdocuments.us/reader033/viewer/2022042405/5f1c46cc4078c7029a1a21b5/html5/thumbnails/20.jpg)
20
![Page 21: New Hampshire Water Works Association - Case … › wp-content › uploads › Surface-Water...Project Overview •Iron & Manganese Treatment Facility –Capacity = 1,250 gpm (1.8](https://reader033.vdocuments.us/reader033/viewer/2022042405/5f1c46cc4078c7029a1a21b5/html5/thumbnails/21.jpg)
21
![Page 22: New Hampshire Water Works Association - Case … › wp-content › uploads › Surface-Water...Project Overview •Iron & Manganese Treatment Facility –Capacity = 1,250 gpm (1.8](https://reader033.vdocuments.us/reader033/viewer/2022042405/5f1c46cc4078c7029a1a21b5/html5/thumbnails/22.jpg)
22
![Page 23: New Hampshire Water Works Association - Case … › wp-content › uploads › Surface-Water...Project Overview •Iron & Manganese Treatment Facility –Capacity = 1,250 gpm (1.8](https://reader033.vdocuments.us/reader033/viewer/2022042405/5f1c46cc4078c7029a1a21b5/html5/thumbnails/23.jpg)
23
![Page 24: New Hampshire Water Works Association - Case … › wp-content › uploads › Surface-Water...Project Overview •Iron & Manganese Treatment Facility –Capacity = 1,250 gpm (1.8](https://reader033.vdocuments.us/reader033/viewer/2022042405/5f1c46cc4078c7029a1a21b5/html5/thumbnails/24.jpg)
24
![Page 25: New Hampshire Water Works Association - Case … › wp-content › uploads › Surface-Water...Project Overview •Iron & Manganese Treatment Facility –Capacity = 1,250 gpm (1.8](https://reader033.vdocuments.us/reader033/viewer/2022042405/5f1c46cc4078c7029a1a21b5/html5/thumbnails/25.jpg)
25
![Page 26: New Hampshire Water Works Association - Case … › wp-content › uploads › Surface-Water...Project Overview •Iron & Manganese Treatment Facility –Capacity = 1,250 gpm (1.8](https://reader033.vdocuments.us/reader033/viewer/2022042405/5f1c46cc4078c7029a1a21b5/html5/thumbnails/26.jpg)
26
![Page 27: New Hampshire Water Works Association - Case … › wp-content › uploads › Surface-Water...Project Overview •Iron & Manganese Treatment Facility –Capacity = 1,250 gpm (1.8](https://reader033.vdocuments.us/reader033/viewer/2022042405/5f1c46cc4078c7029a1a21b5/html5/thumbnails/27.jpg)
27
![Page 28: New Hampshire Water Works Association - Case … › wp-content › uploads › Surface-Water...Project Overview •Iron & Manganese Treatment Facility –Capacity = 1,250 gpm (1.8](https://reader033.vdocuments.us/reader033/viewer/2022042405/5f1c46cc4078c7029a1a21b5/html5/thumbnails/28.jpg)
28
![Page 29: New Hampshire Water Works Association - Case … › wp-content › uploads › Surface-Water...Project Overview •Iron & Manganese Treatment Facility –Capacity = 1,250 gpm (1.8](https://reader033.vdocuments.us/reader033/viewer/2022042405/5f1c46cc4078c7029a1a21b5/html5/thumbnails/29.jpg)
29
![Page 30: New Hampshire Water Works Association - Case … › wp-content › uploads › Surface-Water...Project Overview •Iron & Manganese Treatment Facility –Capacity = 1,250 gpm (1.8](https://reader033.vdocuments.us/reader033/viewer/2022042405/5f1c46cc4078c7029a1a21b5/html5/thumbnails/30.jpg)
31
![Page 31: New Hampshire Water Works Association - Case … › wp-content › uploads › Surface-Water...Project Overview •Iron & Manganese Treatment Facility –Capacity = 1,250 gpm (1.8](https://reader033.vdocuments.us/reader033/viewer/2022042405/5f1c46cc4078c7029a1a21b5/html5/thumbnails/31.jpg)
32
![Page 32: New Hampshire Water Works Association - Case … › wp-content › uploads › Surface-Water...Project Overview •Iron & Manganese Treatment Facility –Capacity = 1,250 gpm (1.8](https://reader033.vdocuments.us/reader033/viewer/2022042405/5f1c46cc4078c7029a1a21b5/html5/thumbnails/32.jpg)
33
![Page 33: New Hampshire Water Works Association - Case … › wp-content › uploads › Surface-Water...Project Overview •Iron & Manganese Treatment Facility –Capacity = 1,250 gpm (1.8](https://reader033.vdocuments.us/reader033/viewer/2022042405/5f1c46cc4078c7029a1a21b5/html5/thumbnails/33.jpg)
34
![Page 34: New Hampshire Water Works Association - Case … › wp-content › uploads › Surface-Water...Project Overview •Iron & Manganese Treatment Facility –Capacity = 1,250 gpm (1.8](https://reader033.vdocuments.us/reader033/viewer/2022042405/5f1c46cc4078c7029a1a21b5/html5/thumbnails/34.jpg)
Performance
35
Raw Finished
Iron 1.5 – 1.89 mg/L 0.03 mg/L
Manganese 0.155 mg/L 0.006 mg/L
Pre-Treated Finished
Chlorine Residual 1.5 – 2.25 mg/L 0.8 – 1.0 mg/L
(no post-feed)
pH 6.8 – 7.0 6.8 – 7.0
(no post-caustic)
Filter Run Times = 48 hours +/- (5 psid)
![Page 35: New Hampshire Water Works Association - Case … › wp-content › uploads › Surface-Water...Project Overview •Iron & Manganese Treatment Facility –Capacity = 1,250 gpm (1.8](https://reader033.vdocuments.us/reader033/viewer/2022042405/5f1c46cc4078c7029a1a21b5/html5/thumbnails/35.jpg)
36
![Page 36: New Hampshire Water Works Association - Case … › wp-content › uploads › Surface-Water...Project Overview •Iron & Manganese Treatment Facility –Capacity = 1,250 gpm (1.8](https://reader033.vdocuments.us/reader033/viewer/2022042405/5f1c46cc4078c7029a1a21b5/html5/thumbnails/36.jpg)
Acknowledgments
• Merrimack Village District
• Blueleaf, Inc.
• NHDES – State Revolving Loan Fund
• PRB Construction
37
![Page 37: New Hampshire Water Works Association - Case … › wp-content › uploads › Surface-Water...Project Overview •Iron & Manganese Treatment Facility –Capacity = 1,250 gpm (1.8](https://reader033.vdocuments.us/reader033/viewer/2022042405/5f1c46cc4078c7029a1a21b5/html5/thumbnails/37.jpg)
Questions?
38