new generation power factor controller · authorized dealer regional sales offices: kolkata mumbai...
TRANSCRIPT
www.epcos.com
New Generation Power Factor Controller
M3 –
M3 –
PFC Controller
PowerFactorCorrectionSystem
Authorized Dealer
Regional Sales Offices:Kolkata Mumbai Tel: +91-22-2575 0800 Fax: +91-22-2575 0810Noida Tel: +91-120-450 5801. Fax: +91-120-450 5818Bengaluru Tel: +91-80-4039 0640. Fax: +91-80-4039 0603
Tel: +91-33-2419 8815. Fax: +91-33-2419 8815
EPCOS India Pvt. Ltd.A TDK Group CompanySales Head Office:14/2, Rajesh Chambers, Brunton Road, Bengaluru 560001. Tel: +91-80-4039 0640. Fax :+91-80-4039 0603.Email: [email protected].
EIPL- PFC Controller Crystal 022016 1
“Product development is a continuous process. Consequently the data indicated in this price list is subject to change without prior notice. For the latest information, contact your local partners.”
For more details on products and applications please contact our nearest sales office or write to us at [email protected]
BR4000ET BR4000ERPF display up to 3rd decimal Upgradable for steps
Intelligent Intelligent
Value for money Wide supply and measurement range
Compact Recall recorded values
l l
l l
l l
l l
Technical Data BR4000ET BR4000ER
Series Type B44066R4…A240 B44066R4…R240
Steps 4,6 and 8 relay output 4,6 and 8 relay output
Supply Voltage 144….288V ( L-N) 110….550V ( L-N/L-L)
Measurement Voltage 144….288V ( L-N) 110….550V ( L-N/L-L)
Frequency (Selectable) 50/60 Hz 40 to 70 Hz
Switching Contactor Contactor
Operating Temperature 0ºC to 55ºC -10ºC to 60ºC
Load CT input Current 1/5A 1/5A
Parameter displayedSystem voltage (V AC) Yes Yes
Reactive power (KVAr) Yes Yes
Active power (kW) Yes Yes
Apparent power (KVA) Yes Yes
Apparent current (A) Yes Yes
Temperature (°C) Yes Yes
Real-time cos Yes Yes
KVAr value to target cos No Yes
THD – V / THD - I in % Yes Yes
Individual Harmonics in % up to 31st for V and I No Yes
Energy kWh (Import/ Export) No Yes
Energy KVAh No Yes
Energy KVARh (Inductive / Capacitive) No Yes
Demand KVA /current No Yes
Run Hour – Number of hours load is connected No Yes
On Hour – hours for which power supply is On No Yes
No of interruption – Number of interruption for power supply No Yes
Alarm Relay No Yes
Out of Bank (Under Compensation) No Yes
Overcompensation No Yes
Under Voltage No Yes
Over Voltage No Yes
Undercurrent No Yes
Overcurrent No Yes
Over temperature No Yes
Under / Over Frequency No Yes
Excess Harmonics ( V-THD / I-THD) No Yes
Recall recorded valuesMaximum / Minimum Voltage No Yes
Maximum / Minimum current No Yes
Maximum / Minimum Apparent power No Yes
Maximum / Minimum Reactive power No Yes
Maximum / Minimum temperature No Yes
Maximum / Minimum THD (V/I) No Yes
Switching count of Capacitor No Yes
Operation time of Capacitor No Yes
Correction Time 10 sec ... 10 min 10 sec …30 min
Discharge Time 10 sec ... 10 min 60 sec …30 min
Dimension 96 × 96 × 51 mm 96 × 96 × 51 mm
Weight 0.5 Kg 0.35 Kg
ø
ø
Though alarm relay is not provided for fault conditions, built in factory set protection is available in BR4000-ET as per set-trip and resume limits