new devices for measuring indoor and outdoor ultra-fine...
TRANSCRIPT
![Page 1: New Devices for Measuring Indoor and Outdoor Ultra-Fine ...chtechusa.com/supplemental-docs/FLPL-Rutgers-presentation.pdf · New Devices for Measuring Indoor and Outdoor Ultra-Fine](https://reader034.vdocuments.us/reader034/viewer/2022050518/5fa2240a17a04371414e4a33/html5/thumbnails/1.jpg)
New Devices for Measuring Indoor
and Outdoor Ultra-Fine
Particulates – A Case Study at the
Fort Lee, NJ, Public Library
Westwood, NJ
August, 2016
![Page 2: New Devices for Measuring Indoor and Outdoor Ultra-Fine ...chtechusa.com/supplemental-docs/FLPL-Rutgers-presentation.pdf · New Devices for Measuring Indoor and Outdoor Ultra-Fine](https://reader034.vdocuments.us/reader034/viewer/2022050518/5fa2240a17a04371414e4a33/html5/thumbnails/2.jpg)
Pegasor AQUrban at a Glance• Ideal tool to measure ambient ultrafine particles
(UFP)
• Provides particle mass concentration, particle
number concentration and particle active surface
area concentration
• Extensive self-diagnosis with alarms in case of
reduced data quality
• Easy installation with little installation space
• Can be used as data source for Finnish Metrology
Institute Enfuser particulate exposure forecast
model
• Various methods for data transfer including direct
storage in the cloud
• Stable with few replacement parts
• Easy maintenance, half to one year maintenance
period
![Page 3: New Devices for Measuring Indoor and Outdoor Ultra-Fine ...chtechusa.com/supplemental-docs/FLPL-Rutgers-presentation.pdf · New Devices for Measuring Indoor and Outdoor Ultra-Fine](https://reader034.vdocuments.us/reader034/viewer/2022050518/5fa2240a17a04371414e4a33/html5/thumbnails/3.jpg)
Pegasor AQIndoor at a Glance
• Ideal device for measuring ultrafine particles
indoors
• Detects temperature, relative humidity and CO2
concentration
• Self diagnostic procedure guarantees accurate
and continuous measurement
• Fits easily to any indoor environment
• Measured data can be read from the touch
screen in graphical and numerical form
• Measured data can be stored on hard disk or
USB and transferred to data storage, cloud
service, or printed out as separate document
• Easy maintenance and long maintenance interval
• Reasonable pricing and very low cost of
ownership
![Page 4: New Devices for Measuring Indoor and Outdoor Ultra-Fine ...chtechusa.com/supplemental-docs/FLPL-Rutgers-presentation.pdf · New Devices for Measuring Indoor and Outdoor Ultra-Fine](https://reader034.vdocuments.us/reader034/viewer/2022050518/5fa2240a17a04371414e4a33/html5/thumbnails/4.jpg)
Pegasor Detection Method
• Passive charging of nanoparticles - escaping-current technology
• Accurate detection range 10 nm – 800 nm (overall range 10 nm to 10 µm)
• Report Lung Deposited Surface Area (LDSA), Concentration
• Concentration range 1-20,000 µm2/cm3 which corresponds to a number concentration of about
500-107 particles/cc
• Can be equipped with TEM collection grid for further analysis of the collected nanoparticles with
electronic microscopy
![Page 5: New Devices for Measuring Indoor and Outdoor Ultra-Fine ...chtechusa.com/supplemental-docs/FLPL-Rutgers-presentation.pdf · New Devices for Measuring Indoor and Outdoor Ultra-Fine](https://reader034.vdocuments.us/reader034/viewer/2022050518/5fa2240a17a04371414e4a33/html5/thumbnails/5.jpg)
Why Use Pegasor Systems
• Evidence is mounting that Ultrafine Particulates may be a major
contributor within the range of environmental particulates that
adversely affect human health and more strongly associated with
such health impacts
• Ambient ultrafine concentration is a good measure of overall
exposure but large human sub-populations, especially those in
urban and suburban areas, generally spend most of the time
indoors
• Even well spaces with well managed incoming air filtration can
constitute UFP exposure hot spots due to internal sources
• The I/O ratio of a facility (indoor vs. outdoor particulate
concentration) can be calculated by monitoring simultaneously
with a Pegasor AQIndoor inside and Pegasor AQUrban outside
the facility
![Page 6: New Devices for Measuring Indoor and Outdoor Ultra-Fine ...chtechusa.com/supplemental-docs/FLPL-Rutgers-presentation.pdf · New Devices for Measuring Indoor and Outdoor Ultra-Fine](https://reader034.vdocuments.us/reader034/viewer/2022050518/5fa2240a17a04371414e4a33/html5/thumbnails/6.jpg)
First Step: Device Calibration
• In order for the Pegasor AQIndoor and Pegasor AQUrban
units to provide meaningful data as an integrated system their
sensors need to deliver equivalent concentration values
• CH Technologies has developed a calibration system based
on the H-1000, a 1 m3 dynamic exposure chamber
• The system uses a BLAM nebulizer to generate a known
aerosol under controlled conditions.
• Both devices are placed inside the chamber and their
measurements are be fine tuned and synced with each-other
by adjusting their operation parameters
• The results are compared against reference devices such as
aerosol spectrometer and SMPS
![Page 7: New Devices for Measuring Indoor and Outdoor Ultra-Fine ...chtechusa.com/supplemental-docs/FLPL-Rutgers-presentation.pdf · New Devices for Measuring Indoor and Outdoor Ultra-Fine](https://reader034.vdocuments.us/reader034/viewer/2022050518/5fa2240a17a04371414e4a33/html5/thumbnails/7.jpg)
Schematic of the Calibration
System
![Page 8: New Devices for Measuring Indoor and Outdoor Ultra-Fine ...chtechusa.com/supplemental-docs/FLPL-Rutgers-presentation.pdf · New Devices for Measuring Indoor and Outdoor Ultra-Fine](https://reader034.vdocuments.us/reader034/viewer/2022050518/5fa2240a17a04371414e4a33/html5/thumbnails/8.jpg)
View of a Calibration System
Prototype
![Page 9: New Devices for Measuring Indoor and Outdoor Ultra-Fine ...chtechusa.com/supplemental-docs/FLPL-Rutgers-presentation.pdf · New Devices for Measuring Indoor and Outdoor Ultra-Fine](https://reader034.vdocuments.us/reader034/viewer/2022050518/5fa2240a17a04371414e4a33/html5/thumbnails/9.jpg)
Example of Sensor Calibration
Results – with 1% NaCl Solution
![Page 10: New Devices for Measuring Indoor and Outdoor Ultra-Fine ...chtechusa.com/supplemental-docs/FLPL-Rutgers-presentation.pdf · New Devices for Measuring Indoor and Outdoor Ultra-Fine](https://reader034.vdocuments.us/reader034/viewer/2022050518/5fa2240a17a04371414e4a33/html5/thumbnails/10.jpg)
Overview of the Case Study
• Pegasor AQUrban monitor deployed on the roof of the Fort Lee, NJ, Public Library during March 18 –June 30, 2016
• Pegasor AQUrban co-located with a gravimetric FRM PM2.5 monitor operated by the NJ Department of Environmental Protection that provides a daily measurement every third day
• Pegasor AQIndoor monitor placed in the children’s reading room of the Library during March 28 – May 9, 2016
• Another Pegasor AQUrban was placed near the upper level east-bound toll plaza of the George Washington Bridge, less than a mile away, as part of a larger study in the area
![Page 11: New Devices for Measuring Indoor and Outdoor Ultra-Fine ...chtechusa.com/supplemental-docs/FLPL-Rutgers-presentation.pdf · New Devices for Measuring Indoor and Outdoor Ultra-Fine](https://reader034.vdocuments.us/reader034/viewer/2022050518/5fa2240a17a04371414e4a33/html5/thumbnails/11.jpg)
Ultrafines Monitoring at Fort Lee
Public Library
![Page 12: New Devices for Measuring Indoor and Outdoor Ultra-Fine ...chtechusa.com/supplemental-docs/FLPL-Rutgers-presentation.pdf · New Devices for Measuring Indoor and Outdoor Ultra-Fine](https://reader034.vdocuments.us/reader034/viewer/2022050518/5fa2240a17a04371414e4a33/html5/thumbnails/12.jpg)
View of Fort Lee Public Library
Building
![Page 13: New Devices for Measuring Indoor and Outdoor Ultra-Fine ...chtechusa.com/supplemental-docs/FLPL-Rutgers-presentation.pdf · New Devices for Measuring Indoor and Outdoor Ultra-Fine](https://reader034.vdocuments.us/reader034/viewer/2022050518/5fa2240a17a04371414e4a33/html5/thumbnails/13.jpg)
Outdoor Ultrafines Monitoring at
GW Bridge Toll Plaza
![Page 14: New Devices for Measuring Indoor and Outdoor Ultra-Fine ...chtechusa.com/supplemental-docs/FLPL-Rutgers-presentation.pdf · New Devices for Measuring Indoor and Outdoor Ultra-Fine](https://reader034.vdocuments.us/reader034/viewer/2022050518/5fa2240a17a04371414e4a33/html5/thumbnails/14.jpg)
Results of Co-Location at GWB –
Comparison with LDSA at FLPL
![Page 15: New Devices for Measuring Indoor and Outdoor Ultra-Fine ...chtechusa.com/supplemental-docs/FLPL-Rutgers-presentation.pdf · New Devices for Measuring Indoor and Outdoor Ultra-Fine](https://reader034.vdocuments.us/reader034/viewer/2022050518/5fa2240a17a04371414e4a33/html5/thumbnails/15.jpg)
Indoor vs. Outdoor Ultrafine
Concentrations
y = 0.176x + 1.9494R² = 0.342
0
10
20
30
40
50
60
70
80
0 50 100 150 200 250 300 350
AQ
I LD
SA
(mm
2/c
m3)
AQU LDSA (mm2/cm3)
Correlation Between AQU and AQI LDSA at Fort Lee Library
![Page 16: New Devices for Measuring Indoor and Outdoor Ultra-Fine ...chtechusa.com/supplemental-docs/FLPL-Rutgers-presentation.pdf · New Devices for Measuring Indoor and Outdoor Ultra-Fine](https://reader034.vdocuments.us/reader034/viewer/2022050518/5fa2240a17a04371414e4a33/html5/thumbnails/16.jpg)
I/O Ratio at Fort Lee Library
![Page 17: New Devices for Measuring Indoor and Outdoor Ultra-Fine ...chtechusa.com/supplemental-docs/FLPL-Rutgers-presentation.pdf · New Devices for Measuring Indoor and Outdoor Ultra-Fine](https://reader034.vdocuments.us/reader034/viewer/2022050518/5fa2240a17a04371414e4a33/html5/thumbnails/17.jpg)
Overview of Measurement
Results at Fort Lee Library
Outdoor LDSA
Indoor LDSA
I/O Ratio
![Page 18: New Devices for Measuring Indoor and Outdoor Ultra-Fine ...chtechusa.com/supplemental-docs/FLPL-Rutgers-presentation.pdf · New Devices for Measuring Indoor and Outdoor Ultra-Fine](https://reader034.vdocuments.us/reader034/viewer/2022050518/5fa2240a17a04371414e4a33/html5/thumbnails/18.jpg)
Main Conclusions of the Case
Study• The combination Pegasor AQUrban and AQIndoor is the
ideal package for monitoring air quality of large indoor spaces
• The CH Technologies proprietary calibration system ensures excellent intra-monitor measurement consistency between AQUrban and AQIndoor monitors
• The average I/O value of 0.25 calculated for the children’s reading room of the Fort Lee Public Library indicates that the ventilation system removes UFP from outside air
• There are episodes occurring almost daily in the early afternoon hours where the calculated I/O ratio values clearly indicate elevated levels of indoor generated UFP
• A follow up study in the library is needed to identify the origin of the internal UFP source(s) and investigate their periodic occurrence
![Page 19: New Devices for Measuring Indoor and Outdoor Ultra-Fine ...chtechusa.com/supplemental-docs/FLPL-Rutgers-presentation.pdf · New Devices for Measuring Indoor and Outdoor Ultra-Fine](https://reader034.vdocuments.us/reader034/viewer/2022050518/5fa2240a17a04371414e4a33/html5/thumbnails/19.jpg)
CONTACTS
CH Technologies (USA), Inc.
Address: 263 Center Avenue
Westwood, NJ 07675, USA
Tel: +1 201 666 2335
Fax: +1 201 666 8611
Email: [email protected]
Website: www.chtechusa.com