new biomedical applications of digital image processing … · 2013. 2. 28. · • carlos lopes...

33
José Fonseca André Mora [email protected] [email protected] Biomedical Applications of Digital Image Processing Biomedical Applications of Digital Image Processing

Upload: others

Post on 26-Sep-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: New Biomedical Applications of Digital Image Processing … · 2013. 2. 28. · • Carlos Lopes MIEEC JORTEC 2013 - 18José Fonseca & André Mora DETECTION OF ABNORMAL IMAGES l Optomap

José Fonseca André Mora [email protected] [email protected]

Biomedical Applications of

Digital Image Processing

Biomedical Applications of Digital Image Processing

Page 2: New Biomedical Applications of Digital Image Processing … · 2013. 2. 28. · • Carlos Lopes MIEEC JORTEC 2013 - 18José Fonseca & André Mora DETECTION OF ABNORMAL IMAGES l Optomap

• Retinography applications

• Biology and Bacteria's applications

• Conclusions

JORTEC 2013 - José Fonseca & André Mora 2

OUTLINE

Page 3: New Biomedical Applications of Digital Image Processing … · 2013. 2. 28. · • Carlos Lopes MIEEC JORTEC 2013 - 18José Fonseca & André Mora DETECTION OF ABNORMAL IMAGES l Optomap

RETINAL DRUSEN DETECTION

JORTEC 2013 - José Fonseca & André Mora 3

Page 4: New Biomedical Applications of Digital Image Processing … · 2013. 2. 28. · • Carlos Lopes MIEEC JORTEC 2013 - 18José Fonseca & André Mora DETECTION OF ABNORMAL IMAGES l Optomap

• Drusen are retina abnormalities caused by accumulation of extracellular materials beneath retina surface

• ARMD indicator and can produce loss of vision

• Visible in retina Fundus photography as yellowish spots around the macula

• Objective: To detect and quantify affected area

JORTEC 2013 - José Fonseca & André Mora 4

DRUSEN DETECTION

Transversal view

Surface view

Page 5: New Biomedical Applications of Digital Image Processing … · 2013. 2. 28. · • Carlos Lopes MIEEC JORTEC 2013 - 18José Fonseca & André Mora DETECTION OF ABNORMAL IMAGES l Optomap

• Assumption: retina images allow 3D shape estimation

– In a 2D grey scale image the intensity value can represent the

3rd coordinate (depth)

• Proposed algorithm:

– Step 1 – Illumination correction

– Step 2 – detection of retina spots that can be related to Drusen

– Step 3 – modelling of each retina spot using a 3D function

JORTEC 2013 - José Fonseca & André Mora 5

CONSIDERATIONS

2D view Estimated

3D view

Page 6: New Biomedical Applications of Digital Image Processing … · 2013. 2. 28. · • Carlos Lopes MIEEC JORTEC 2013 - 18José Fonseca & André Mora DETECTION OF ABNORMAL IMAGES l Optomap

JORTEC 2013 - José Fonseca & André Mora 6

AD3RI METHODOLOGY

ROI Definition Correct illumination Locate Drusen spots

(GPL algorithm) Green Channel Norm. Contrast

Page 7: New Biomedical Applications of Digital Image Processing … · 2013. 2. 28. · • Carlos Lopes MIEEC JORTEC 2013 - 18José Fonseca & André Mora DETECTION OF ABNORMAL IMAGES l Optomap

7

GRADIENT PATH LABELLING (GPL)

11

11

10

10

10

10

2

Image gradient (Sobel operator)

Labels propagation

Step1

Step2 Step3

Apply label

compatibilities

3

12 13

14 15 16 17 13 18

19 20 21 18 22

23 24 25 25 25 22 26

27 28 29 30 31 32 33

34 35 36 37 37 38 39 40

1

1

1

5

5

4

4

6

6

6 6

8 7

7

7

7

7 7

7

7

9

1 1 1 1 1 1 7 7

1 1 1 1 1 7 7 7

1 1 1 1 7 7 7 7

1 1 1 7 7 7 7 7

1 1 7 7 7 7 7 7

1 7 7 7 7 7 7 7

1 7 7 7 7 7 7 7

1 7 7 7 7 7 7 7

Ori

gin

al im

ag

e

JORTEC 2013 - José Fonseca & André Mora

Page 8: New Biomedical Applications of Digital Image Processing … · 2013. 2. 28. · • Carlos Lopes MIEEC JORTEC 2013 - 18José Fonseca & André Mora DETECTION OF ABNORMAL IMAGES l Optomap

JORTEC 2013 - José Fonseca & André Mora 8

AD3RI METHODOLOGY

ROI Definition Correct illumination Locate Drusen spots

(GPL algorithm)

Model Drusen spots Threshold model

Green Channel Norm. Contrast

Page 9: New Biomedical Applications of Digital Image Processing … · 2013. 2. 28. · • Carlos Lopes MIEEC JORTEC 2013 - 18José Fonseca & André Mora DETECTION OF ABNORMAL IMAGES l Optomap

JORTEC 2013 - José Fonseca & André Mora 9

EVALUATION TESTS – PIXEL LEVEL

AD3RI

MD3RI

Pixel level Comparison

(TP, FP, TN, FN)

Pixel level analysis

Sensitivity / Specificity

Kappa coefficient

MD3RI AD3RI

SS = 0.69

SP = 0.96

K = 0.58

Page 10: New Biomedical Applications of Digital Image Processing … · 2013. 2. 28. · • Carlos Lopes MIEEC JORTEC 2013 - 18José Fonseca & André Mora DETECTION OF ABNORMAL IMAGES l Optomap

IMAGE ARTIFACTS DETECTION

JORTEC 2013 - José Fonseca & André Mora 10

Page 11: New Biomedical Applications of Digital Image Processing … · 2013. 2. 28. · • Carlos Lopes MIEEC JORTEC 2013 - 18José Fonseca & André Mora DETECTION OF ABNORMAL IMAGES l Optomap

• Images’ quality can be affected by: – Bad collaboration from the patient

– Dust over the lens

• The effects are: – Non-uniform illumination

– Flares (artifacts)

– Central Artifact

• MSc João Soares MIEBM

JORTEC 2013 - José Fonseca & André Mora 11

FUNDUS IMAGE ACQUISITION PROBLEMS

Fingerprint

Page 12: New Biomedical Applications of Digital Image Processing … · 2013. 2. 28. · • Carlos Lopes MIEEC JORTEC 2013 - 18José Fonseca & André Mora DETECTION OF ABNORMAL IMAGES l Optomap

JORTEC 2013 - José Fonseca & André Mora 12

DETECTION PROCEDURE

Template Matching

Saturation Channel

Image Template

Flare validation

Image and Template

correlation

Page 13: New Biomedical Applications of Digital Image Processing … · 2013. 2. 28. · • Carlos Lopes MIEEC JORTEC 2013 - 18José Fonseca & André Mora DETECTION OF ABNORMAL IMAGES l Optomap

ARTERIOLAR TO VENULAR RATIO (AVR)

JORTEC 2013 - José Fonseca & André Mora 13

Page 14: New Biomedical Applications of Digital Image Processing … · 2013. 2. 28. · • Carlos Lopes MIEEC JORTEC 2013 - 18José Fonseca & André Mora DETECTION OF ABNORMAL IMAGES l Optomap

• The retina arteriolar to venular diameter ratio is suggested to reflect generalized vascular alterations and to predict the risk of cardiovascular diseases.

• Procedure: – Optic disk detection

– Vessels detection

– Arteriole / Venule Classification

– AVR calculation

– MSc Student Tânia Tomaz MIEBM

JORTEC 2013 - José Fonseca & André Mora 14

ARTERIOLAR TO VENULAR RATIO (AVR)

Page 15: New Biomedical Applications of Digital Image Processing … · 2013. 2. 28. · • Carlos Lopes MIEEC JORTEC 2013 - 18José Fonseca & André Mora DETECTION OF ABNORMAL IMAGES l Optomap

JORTEC 2013 - José Fonseca & André Mora 15

OPTIC DISK DETECTION

Morphologic Close

Edge Detection

Threshold Hough

Transform

Page 16: New Biomedical Applications of Digital Image Processing … · 2013. 2. 28. · • Carlos Lopes MIEEC JORTEC 2013 - 18José Fonseca & André Mora DETECTION OF ABNORMAL IMAGES l Optomap

JORTEC 2013 - José Fonseca & André Mora 16

VESSELS DETECTION AND CLASSIFICATION

Circular projection

Vessels detection

Vessels classification

Page 17: New Biomedical Applications of Digital Image Processing … · 2013. 2. 28. · • Carlos Lopes MIEEC JORTEC 2013 - 18José Fonseca & André Mora DETECTION OF ABNORMAL IMAGES l Optomap

DETECT ABNORMAL IMAGES

JORTEC 2013 - José Fonseca & André Mora 17

Page 18: New Biomedical Applications of Digital Image Processing … · 2013. 2. 28. · • Carlos Lopes MIEEC JORTEC 2013 - 18José Fonseca & André Mora DETECTION OF ABNORMAL IMAGES l Optomap

– Objective: On screening and using Retinal Auto-fluorescence images, detect patients that have retinal abnormalities and need to visit their ophthalmologist

– Procedure: • Detect deviations from a normal retina

auto-fluorescence pattern

– MSc Students: • Sara Praça MIEBM

• Carlos Lopes MIEEC

JORTEC 2013 - José Fonseca & André Mora 18

DETECTION OF ABNORMAL IMAGES

Norm

al

Optomap

(ultra-wide field) HRA

Ab

no

rma

l

Page 19: New Biomedical Applications of Digital Image Processing … · 2013. 2. 28. · • Carlos Lopes MIEEC JORTEC 2013 - 18José Fonseca & André Mora DETECTION OF ABNORMAL IMAGES l Optomap

BACTERIA SEGMENTATION

JORTEC 2013 - José Fonseca & André Mora 19

Page 20: New Biomedical Applications of Digital Image Processing … · 2013. 2. 28. · • Carlos Lopes MIEEC JORTEC 2013 - 18José Fonseca & André Mora DETECTION OF ABNORMAL IMAGES l Optomap

• The need of reliable and fast methods of single cell evaluation for statistically significant studies

• Extraction of individual cells information from bacterial populations with large number of elements

• Avoid manual analysis which is fastidious, time consuming and subject to observer variances

JORTEC 2013 - José Fonseca & André Mora 20

WHY BACTERIA SEGMENTATION AND TRACKING?

Page 21: New Biomedical Applications of Digital Image Processing … · 2013. 2. 28. · • Carlos Lopes MIEEC JORTEC 2013 - 18José Fonseca & André Mora DETECTION OF ABNORMAL IMAGES l Optomap

JORTEC 2013 - José Fonseca & André Mora 21

THE PROBLEM

DIC - Diferential Interference Contrast Microscopy

image Confocal Fluorescence Microscopy image

Page 22: New Biomedical Applications of Digital Image Processing … · 2013. 2. 28. · • Carlos Lopes MIEEC JORTEC 2013 - 18José Fonseca & André Mora DETECTION OF ABNORMAL IMAGES l Optomap

JORTEC 2013 - José Fonseca & André Mora 22

IMAGE PROCESSING STEPS

DIC image

Segmented

image

Cleaned

image

GPL

Discard classifier

Merge classifier

Merged

image

Fluorescence

image

Cells evaluation

Image alignment

Aligned

image 1

Aligned

image 2

Aligned

image 3

Aligned

image 4

Aligned

image n

Temporal filtering

Page 23: New Biomedical Applications of Digital Image Processing … · 2013. 2. 28. · • Carlos Lopes MIEEC JORTEC 2013 - 18José Fonseca & André Mora DETECTION OF ABNORMAL IMAGES l Optomap

JORTEC 2013 - José Fonseca & André Mora 23

BACTERIA (OVER)SEGMENTATON

Gradient Path Labelling (Sobel operator) Original image

Page 24: New Biomedical Applications of Digital Image Processing … · 2013. 2. 28. · • Carlos Lopes MIEEC JORTEC 2013 - 18José Fonseca & André Mora DETECTION OF ABNORMAL IMAGES l Optomap

JORTEC 2013 - José Fonseca & André Mora 24

OVERSEGMENTED IMAGE

Page 25: New Biomedical Applications of Digital Image Processing … · 2013. 2. 28. · • Carlos Lopes MIEEC JORTEC 2013 - 18José Fonseca & André Mora DETECTION OF ABNORMAL IMAGES l Optomap

JORTEC 2013 - José Fonseca & André Mora 25

“CLEANED” IMAGE BY CART DECISION TREE

Page 26: New Biomedical Applications of Digital Image Processing … · 2013. 2. 28. · • Carlos Lopes MIEEC JORTEC 2013 - 18José Fonseca & André Mora DETECTION OF ABNORMAL IMAGES l Optomap

JORTEC 2013 - José Fonseca & André Mora 26

“MERGED IMAGE” BY CART DECISION TREE

Page 27: New Biomedical Applications of Digital Image Processing … · 2013. 2. 28. · • Carlos Lopes MIEEC JORTEC 2013 - 18José Fonseca & André Mora DETECTION OF ABNORMAL IMAGES l Optomap

JORTEC 2013 - José Fonseca & André Mora 27

DIC AND FLUORESCENCE IMAGES ALIGNMENT

Page 28: New Biomedical Applications of Digital Image Processing … · 2013. 2. 28. · • Carlos Lopes MIEEC JORTEC 2013 - 18José Fonseca & André Mora DETECTION OF ABNORMAL IMAGES l Optomap

JORTEC 2013 - José Fonseca & André Mora 28

DIC AND FLUORESCENCE IMAGES ALIGNED

Page 29: New Biomedical Applications of Digital Image Processing … · 2013. 2. 28. · • Carlos Lopes MIEEC JORTEC 2013 - 18José Fonseca & André Mora DETECTION OF ABNORMAL IMAGES l Optomap

JORTEC 2013 - José Fonseca & André Mora 29

INTER-FRAME CORRECTION

frame n-1 frame n frame n+1

frame n after inter-frame correction

Page 30: New Biomedical Applications of Digital Image Processing … · 2013. 2. 28. · • Carlos Lopes MIEEC JORTEC 2013 - 18José Fonseca & André Mora DETECTION OF ABNORMAL IMAGES l Optomap

JORTEC 2013 - José Fonseca & André Mora 30

INDIVIDUAL CELLS FLUORESCENCE EVALUATION

Page 31: New Biomedical Applications of Digital Image Processing … · 2013. 2. 28. · • Carlos Lopes MIEEC JORTEC 2013 - 18José Fonseca & André Mora DETECTION OF ABNORMAL IMAGES l Optomap

• This work was developed in close collaboration with the Laboratory of Biosystem Dynamics, Department of Signal Processing, Tampere University of Technology (TUT)

• Special thanks to Professor André Ribeiro (TUT)

• Local contributors: – MSc Leonardo Martins (finished) - MIEBM

– MSc Cátia Queimadelas (finished) - MIEBM

– MSc João Rodrigues (on going) - MIEBM

– MSc Pedro Ferreira (just started) – MIEEC

JORTEC 2013 - José Fonseca & André Mora 31

CREDITS

Page 32: New Biomedical Applications of Digital Image Processing … · 2013. 2. 28. · • Carlos Lopes MIEEC JORTEC 2013 - 18José Fonseca & André Mora DETECTION OF ABNORMAL IMAGES l Optomap

• The proposed method shown to be able to extract the necessary information from individual cells with acceptable error

• The method can be used to support studies if gene expression dynamics using tsr-venus proteins to assess the kinetics of expression of the gene of interest

• The evaluation of more time-series and possible improvements on image quality will certainly lead to error reduction and improved cell evaluation

JORTEC 2013 - José Fonseca & André Mora 32

CONCLUSIONS

Page 33: New Biomedical Applications of Digital Image Processing … · 2013. 2. 28. · • Carlos Lopes MIEEC JORTEC 2013 - 18José Fonseca & André Mora DETECTION OF ABNORMAL IMAGES l Optomap

THANK YOU FOR YOUR ATTENTION

JORTEC 2013 - José Fonseca & André Mora 33