ndt container colenta - colenta labortechnik gmbh & co … · - standard ndt film viewer -...

5
NDT Container Colenta COLENTA LABORTECHNIK Ges.m.b.H. & Co. KG Neunkirchner Strasse 117 A-2700 Wiener Neustadt Tel.: +43-2622-28311-0 Fax: +43-2622-28311-7 E-mail: [email protected] http://www.colenta.at ACI-COLENTA INTERNATIONAL Div. Capix House, 29 Levellers Lane, St. Neots. Cambs. PE19 2JL - UK Tel. +44-1480-211118 Fax:+44-1480-215236 Fax: +44/870/132 1352 E-mail: [email protected] Standards incl. - insulated 16 foot Container - 2 x AC and 2 x heating system, - “ready to use” internal electrics - “ready to use” water and drainage - Processor INDX 43/x incl chiller - film storage - work bench plus chair - manual film processing unit - dryer cabinet - darkroom safe light - standard NDT film viewer - cabinet - sink and water heating (symbolic image) Safe Light normal Light Automatik NDT Film Processor 43/3 or 43/5 Wash Sink Chemical Waste Chemical Supply Film Storage Film in Manual Tank processing Office desk Film viewer Air condition 1 Air condition 2 Film viewer cabinet cabinet Manual tank processing unit Work bench plus chair (symbolic image) dark room lamp dark room lamp Film Storage ready installed New from Colenta: Colenta Mobile Inspection Technology - The range of Colenta NDT products, produced for industrial x-ray inspection applications, are well established and respected world-wide and now include customized containers that provide mobile film-lab processing facilities on-site as and where required.

Upload: dothu

Post on 21-May-2018

237 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: NDT Container Colenta - Colenta Labortechnik GmbH & Co … · - standard NDT film viewer - cabinet - sink and water heating ... The range of Colenta NDT products, produced for industrial

NDT Container Colenta

COLENTA LABORTECHNIKGes.m.b.H. & Co. KGNeunkirchner Strasse 117A-2700 Wiener NeustadtTel.: +43-2622-28311-0Fax: +43-2622-28311-7E-mail: [email protected]://www.colenta.at

ACI-COLENTAINTERNATIONAL Div.Capix House, 29 Levellers Lane,St. Neots. Cambs. PE19 2JL - UKTel. +44-1480-211118Fax:+44-1480-215236Fax: +44/870/132 1352E-mail: [email protected]

Standards incl.- insulated 16 foot Container- 2 x AC and 2 x heating system,- “ready to use” internal electrics- “ready to use” water and drainage

- Processor INDX 43/x incl chiller- film storage- work bench plus chair- manual film processing unit- dryer cabinet- darkroom safe light- standard NDT film viewer- cabinet- sink and water heating

(symbolic image)

Safe Lightnormal Light

Automatik NDT FilmProcessor 43/3 or 43/5

Was

h Sin

k

Chem

ical

Was

te

Chem

ical

Supp

ly

FilmStorage

Film

in

Manual Tankprocessing

Office desk

Film viewer

Air condition 1 Air condition 2

Film viewer

cabinet

cabinet

Manual tankprocessing unit

Work bench plus chair

(symbolic image)dark room lamp

dark room lamp

Film Storage

ready installed

New from Colenta: Colenta Mobile Inspection Technology - The range of Colenta NDT products, produced forindustrial x-ray inspection applications, are well established and respected world-wide and now include customizedcontainers that provide mobile film-lab processing facilities on-site as and where required.

Page 2: NDT Container Colenta - Colenta Labortechnik GmbH & Co … · - standard NDT film viewer - cabinet - sink and water heating ... The range of Colenta NDT products, produced for industrial

NDT Container Colenta

COLENTA LABORTECHNIKGes.m.b.H. & Co. KGNeunkirchner Strasse 117A-2700 Wiener NeustadtTel.: +43-2622-28311-0Fax: +43-2622-28311-7E-mail: [email protected]://www.colenta.at

ACI-COLENTAINTERNATIONAL Div.Capix House, 29 Levellers Lane,St. Neots. Cambs. PE19 2JL - UKTel. +44-1480-211118Fax:+44-1480-215236Fax: +44/870/132 1352E-mail: [email protected]

Safe Light

Processor43/3 - 43/5Chemical Supply

FilmStorage

Manual Tankprocessing

Film viewer & office desk

Air condition 1

Air condition 2

dark room lamp

processoer exhaust

normal light

Wash Sink

Safe Light

Processor43/3 - 43/5

Chemical

Waste

FilmStorage

Manual Tankprocessing

Film viewer & office desk

cabinet

dark room lamp

processoer ex

haust

normal light

Wash Sink

dark room lamp

heating 2

heating 1

These images show the internal structure of the container with examples of a typical designformat for equipment and services. Each container is supplied to the specific requirements of thecustomer including safety standards such as:

- hand-held fire extinguisher

- eye shower system

- first aid kit

Heating

Page 3: NDT Container Colenta - Colenta Labortechnik GmbH & Co … · - standard NDT film viewer - cabinet - sink and water heating ... The range of Colenta NDT products, produced for industrial

NDT Container Colenta

COLENTA LABORTECHNIKGes.m.b.H. & Co. KGNeunkirchner Strasse 117A-2700 Wiener NeustadtTel.: +43-2622-28311-0Fax: +43-2622-28311-7E-mail: [email protected]://www.colenta.at

ACI-COLENTAINTERNATIONAL Div.Capix House, 29 Levellers Lane,St. Neots. Cambs. PE19 2JL - UKTel. +44-1480-211118Fax:+44-1480-215236Fax: +44/870/132 1352E-mail: [email protected]

Choice of processor:- INDX 43/3 - (25cm/min at 8min Dry to Dry)

incl Chillerincl 2x30 Litre Reptanks plus level controlincl 2x20 litre Waste tanks plus level controlincl fill up system for Dev and Fix

or

- INDX 43/5 (31cm/min at 8min Dry to Dry)incl Chillerincl 2x30 Litre Reptanks plus level controlincl 2x20 litre Waste tanks plus level controlincl fill up system for Dev and Fix

Included with processor:

Covered Film Feed Tray

rack carrier drip tray

level controll forreplenisher tanks

internal chiller unit

ready installed

Transport SystemINDX 43/3MW

Media exit

DRY

DEV FIX WASH

Transport SystemINDX 43/5MW

DEV FIX WASH

DRY

Anti run-back systemwith fixer.

Media exit(Main-Wash)

Pre-Wash

(Main-Wash)

Anti run-back systemwith fixer.

Pre-Wash

Media in

Media in

Optional available:- automatic Film dryer INDX Dryer 37

Page 4: NDT Container Colenta - Colenta Labortechnik GmbH & Co … · - standard NDT film viewer - cabinet - sink and water heating ... The range of Colenta NDT products, produced for industrial

NDT Container Colenta

COLENTA LABORTECHNIKGes.m.b.H. & Co. KGNeunkirchner Strasse 117A-2700 Wiener NeustadtTel.: +43-2622-28311-0Fax: +43-2622-28311-7E-mail: [email protected]://www.colenta.at

ACI-COLENTAINTERNATIONAL Div.Capix House, 29 Levellers Lane,St. Neots. Cambs. PE19 2JL - UKTel. +44-1480-211118Fax:+44-1480-215236Fax: +44/870/132 1352E-mail: [email protected]

configuration:- “ready to use” internal power supply accordingVDE (400V/32A) to cover all power requirements for the

- processor- light (normal and safe light)- venting the container- AC for container- 3 different extra 230V consumers at max 16Aall covered by internal fusing / line breakers

- optional with external power generator!

- A “ready to use” water supply unit including a prefilter system and flowrate control to cover the requirements for the

- processor- manual developing unit- cleaning sink incl. shower unit (for rack cleaning)- one extra free hose for chemical mixing and tank cleaning

- “ready installed” water drain system, to collect all the wastewater

ready installed

ready installed

(symbolic image)

to the processorManual tankprocessing unit

Wash sink

out of the container .....

The design of these self contained mobile units are individually planned to meet a customers specific requirements in terms offilm processing equipment, film handling/viewing and interior layout. All equipment and services are securely fixed to provide safe and reliablehandling both in transit and when in use.

Page 5: NDT Container Colenta - Colenta Labortechnik GmbH & Co … · - standard NDT film viewer - cabinet - sink and water heating ... The range of Colenta NDT products, produced for industrial

NDT Container Colenta

COLENTA LABORTECHNIKGes.m.b.H. & Co. KGNeunkirchner Strasse 117A-2700 Wiener NeustadtTel.: +43-2622-28311-0Fax: +43-2622-28311-7E-mail: [email protected]://www.colenta.at

ACI-COLENTAINTERNATIONAL Div.Capix House, 29 Levellers Lane,St. Neots. Cambs. PE19 2JL - UKTel. +44-1480-211118Fax:+44-1480-215236Fax: +44/870/132 1352E-mail: [email protected]

Safe Light normal Light

Dimensions : 16 foot container- inside height : 2350 mm- door height : 2 x 1940 mm

- total weight : net 1700 kg / incl Colenta accessories about 2200 kg- fork lifting points : 1650 mm / or crane handling- all dimensions are - mm -