napco ma1000e program sheet - alarmsunlimitedinc ma1000e... · property of monitronics inc napco...

8
Property of Monitronics Inc Napco MA1000E Program Sheet Enter Program 1. Hold 8 key for 3 seconds, keypad will beep 2. Enter 4 5 6 7 8 9, display should show dash on display Program Location 1. Press [B/A] key display will show 3 dashs 2. Enter 3-digit location (use B/A for any 0) 3. Value currently programmed in location will display 4. Scroll Value UP with 4 key, scroll Value DOWN with 7, blank location with 5 5. When display shows desired Value press 2 to move to next location (Or B/A + 3-digit location to move to elsewhere) Programming with LCD layout is slightly different LCD Keypads 1 scrolls left 2 scrolls right 5 scrolls data up 9 scrolls data down Exit Program 1. Hold 8 key 3 seconds, keypad will flash and beep 2. Enter 4 5 6 7 8 9, display should return to normal Enable Panics Open Keypad cover, cute Jumper "E" (bottom left jumper, clearly marked) Lockout Bypass 1. Run jumper to pins on large chip marked X (see wiring diagram) 2. Press 9 for 3 seconds, then 8 for 3 seconds and enter 456789 3. LED display should show --- , remove jumper and program normallly (wire MUST be removed to view or change locations) Report Codes Zone 1 31 Duress 21 to 29 Zone 2 32 Keypad Fire Panic 19 Zone 3 33 Keypad Police Panic 29 Zone 4 34 Keypad Medical Panic 49 Zone 5 35 Low Battery 78 Zone 6 36 Low Battery Restoral 98 Zone 7 37 AC Failure 79 Zone 8 38 AC Failure Restoral 99 Zone 9 39 Fire Trouble 76 Zone 10 41 Fire Restore 96 Zone 11 42 Smoke Detector* 16 or 18 Zone 12 43 Cancel D1 to D8 Zone 13 44 Opening 5 + User Zone 14 45 Closing 6 + User Zone 15 46 Test/Download Complete EE Zone 16 47 Zone Restores 9 + Zone IF something screws up power down then up, you have 30 seconds to get into programming Created by Mark Leuck 02/02/2002 Monitronics International, Inc.

Upload: vuongtuyen

Post on 28-Oct-2018

218 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: Napco MA1000E Program Sheet - ALARMSUNLIMITEDINC MA1000E... · Property of Monitronics Inc Napco MA1000E Program Sheet Enter Program 1. Hold 8 key for 3 seconds, keypad will beep

Prop

erty

of M

onitr

onics

Inc

Napco MA1000E Program Sheet

Enter Program 1. Hold 8 key for 3 seconds, keypad will beep 2. Enter 4 5 6 7 8 9, display should show dash on display

Program Location 1. Press [B/A] key display will show 3 dashs 2. Enter 3-digit location (use B/A for any 0) 3. Value currently programmed in location will display 4. Scroll Value UP with 4 key, scroll Value DOWN with 7, blank location with 5 5. When display shows desired Value press 2 to move to next location (Or B/A + 3-digit location to move to elsewhere)

Programming with LCD layout is slightly different LCD Keypads 1 scrolls left 2 scrolls right 5 scrolls data up 9 scrolls data down

Exit Program 1. Hold 8 key 3 seconds, keypad will flash and beep 2. Enter 4 5 6 7 8 9, display should return to normal

Enable Panics Open Keypad cover, cute Jumper "E" (bottom left jumper, clearly marked)

Lockout Bypass 1. Run jumper to pins on large chip marked X (see wiring diagram) 2. Press 9 for 3 seconds, then 8 for 3 seconds and enter 456789 3. LED display should show --- , remove jumper and program normallly (wire MUST be removed to view or change locations)

Report Codes Zone 1 31 Duress 21 to 29 Zone 2 32 Keypad F ire Panic 19 Zone 3 33 Keypad Police Panic 29 Zone 4 34 Keypad Medical Panic 49 Zone 5 35 Low Battery 78 Zone 6 36 Low Battery Restoral 98 Zone 7 37 AC Failure 79 Zone 8 38 AC Failure Restoral 99 Zone 9 39 Fire Trouble 76 Zone 10 41 Fire Restore 96 Zone 11 42 Smoke Detector* 16 or 18 Zone 12 43 Cancel D1 to D8 Zone 13 44 Opening 5 + User Zone 14 45 Closing 6 + User Zone 15 46 Test/Download Complete EE Zone 16 47 Zone Restores 9 + Zone

IF something screws up power down then up, you have 30 seconds to get into programming

Created by Mark Leuck 02/02/2002 Monitronics International, Inc.

Page 2: Napco MA1000E Program Sheet - ALARMSUNLIMITEDINC MA1000E... · Property of Monitronics Inc Napco MA1000E Program Sheet Enter Program 1. Hold 8 key for 3 seconds, keypad will beep

Prop

erty

of M

onitr

onics

Inc

Napco MA1000E Program Sheet

-------------------------------------------------< Report Options >------------------------------------------------- To program REPORT OPTIONS in locations 166 to 185 see below Diagram

Add location together and enter sum in location Example: Enable Reporting for Zones 1 to 6, Keypad Panic, Fire, Duress, Fire Trouble, AC Fail and Low Bat 1. Press B/A then 1 6 6 to move to Location 166 2. Add ZONE 1 (1) + ZONE 2 (2) + ZONE 3 (4) + ZONE 4 (8) = 15 or F, enter the F in location 166 3. Press 2 key to move to 167 4. Add Zone 5 (1) + Zone 6 (2) + Keypad Panic (8) = 11 (B), enter the B in location 167 5. Press 2 key to move to 168 6. Add FIRE ZONE (1) + AMBUSH (2) + FIRE TROUBLE (4) = 7, enter the 7 in location 168 7. Press 2 key to move to 169 8. Add AC FAIL (2) + LOW BAT (4) = 6, enter the 6 in location 169

Report Enable Zone 1 to 4 I__F _I Fire/Duress, Fire Trouble I__7__I 166 168 Report Enable Zones 5, 6 & Panic I__B _I AC Fail/Low Bat Trouble I__6__I

167 169 Restores Enabled I__ __I__ __I Misc Restores I__ __I__ __I (Blank out this section) 170 171 (Blank out this section) 172 173

Zone Restores I__ __I__ __I (Blank out this section) 184 185 -------------------------------------------------< Report Codes >------------------------------------------------- Zone 1 Report Code I__3__I__1__I Keypad Police Panic I__2__I__9__I 000 001 014 015 Zone 2 Report Code I__3__I__2__I Fire Panic/Smoke Detector* I__1__I__6__I 002 003 016 017 Zone 3 Report Code I__3__I__3__I Hostage/Duress I__2__I__6__I 004 005 018 019 Zone 4 Report Code I__3__I__4__I Fire Trouble I__7__I__6__I 006 007 020 021 Zone 5 Report Code I__3__I__5__I Day Zone Trouble I__ __I__ __I 008 009 022 023 Zone 6 Report Code I__3__I__6__I Test Timer I__ __I__ __I 010 011 024 025 Not Used I__ __I__ __I AC Failure I__7__I__9__I 012 013 026 027 Low Battery I__7__I__8__I

(I__ __I__ __I = Blank out Locations with 5 key) 028 029 *Fire Panic and Smoke Detector share signal if Smoke Detector uses dedicated Fire Zone

-------------------------------------------------< Restore Codes >-------------------------------------------------

Zone 1 Restore I__ __I__ __I Fire Panic/Smoke I__ __I__ __I 040 041 056 057 Zone 2 Restore I__ __I__ __I Not Used I__ __I__ __I 042 043 058 059 Zone 3 Restore I__ __I__ __I Fire Trouble I__ __I__ __I 044 045 060 061 Zone 4 Restore I__ __I__ __I Medical Panic I__4__I__9__I 046 047 062 063 Zone 5 Restore I__ __I__ __I Not Used I__ __I__ __I 048 049 064 065 Zone 6 Restore I__ __I__ __I AC Trouble Restore I__ __I__ __I 050 051 066 067 Low Battery Restore I__ __I__ __I

(I__ __I__ __I = Blank out Locations with 5 key) 068 069

Created by Mark Leuck 02/02/2002 Monitronics International, Inc.

Page 3: Napco MA1000E Program Sheet - ALARMSUNLIMITEDINC MA1000E... · Property of Monitronics Inc Napco MA1000E Program Sheet Enter Program 1. Hold 8 key for 3 seconds, keypad will beep

Prop

erty

of M

onitr

onics

Inc

Napco MA1000E Program Sheet

-----------------------------------------< Opening/Closings/Cancel >------------------------------------------

Closing User 1 I__ __I__ __I Opening User 1 I__D__I__1__I 030 031 070 071 Closing User 2 I__ __I__ __I Opening User 2 I__D__I__1__I 032 033 072 073 Closing User 3 I__ __I__ __I Opening User 3 I__D__I__1__I 034 035 074 075 Closing User 4 I__ __I__ __I Opening User 4 I__D__I__1__I 036 037 076 077 Force Arm I__ __I__ __I (These are Cancels, see also section 179) 038 039 Select User Closings I__ __I Select User Openings I__ __I

174 176

(I__ __I__ __I = Blank out Locations with 5 key) -----------------------------------------------< Account Numbers >-----------------------------------------------

Telephone Number 1 (Last 4 of Account must be entered in each section) Group 1 Account Group 2 Account Open/Close Account I__?__I__?__I__?__I__?__I I__?_ _I__?__I__?__I__?__I I__ __I__ __I_ _ __I_ _ __I

100 101 102 103 104 105 106 107 108 109 110 111

Telephone Number 2 (Leave Blank) Group 1 Account Group 2 Account Open/Close Account I__ __I__ __I_ _ __I_ _ __I I__ __I__ __I_ _ __I_ _ __I I__ __I__ __I_ _ __I_ _ __I

132 133 134 135 136 137 138 139 140 141 142 143

------------------------------------------------< Phone Numbers >------------------------------------------------

Report Format Phone 1 I__9__I__2__I

112 113 First Digit Second Digit Blank = Ademco/Silent Knight Slow Blank = Extended or Single Digit 1 = Sescoa, Vertex, DCI, Franklin 1 = Single Digit 2 = Radionics Fast 2 = 2-Digit (4/2) 3 = Silent Knight Fast 4 = Sumcheck 4 = Radionics, DCI, Franklin Slow 5 = Universal Hi Speed 8 = 2300 Handshake (Add this to above numbers)

Receiver 1 Options I__ __I__ __I (Add D in 114 if delay needed to dial out)

114 115 (Add 9 in 115 if 9 is needed to dial out) Receiver 1 Phone I_ E_ I__ _I_ _ __I__ __I_ _ __I__ __I_ _ __I__ __I_ _ __I__ __I_ _ __I__ __I_ _ __I__ __I__ __I_ _ __I

116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 Report Format Phone 2 I__ __I__ __I (Leave blank) 144 145 Receiver 2 Options I__ __I__ __I (Leave blank) 146 147 Receiver 2 Phone I_ E_ I__ __I_ _ __I__ __I_ _ __I__ __I_ _ __I__ __I_ _ __I__ __I_ _ __I__ __I_ _ __I__ __I__ __I_ _ __I

148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 Rings before Download I__9__I (9 rings until Answer) 269 Download Phone 1 I__ __I_ _ __I__ __I_ _ __I__ __I_ _ __I__ __I_ _ __I__ __I_ _ __I__ __I_ _ __I__ __I__ __I_ _ __I_ _ __I

270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 Download Phone 2 I__ __I_ _ __I__ __I_ _ __I__ __I_ _ __I__ __I_ _ __I__ __I_ _ __I__ __I_ _ __I__ __I__ __I_ _ __I_ _ __I

286 297 288 289 290 291 292 293 294 295 296 297 298 299 300 301

Created by Mark Leuck 02/02/2002 Monitronics International, Inc.

Page 4: Napco MA1000E Program Sheet - ALARMSUNLIMITEDINC MA1000E... · Property of Monitronics Inc Napco MA1000E Program Sheet Enter Program 1. Hold 8 key for 3 seconds, keypad will beep

Prop

erty

of M

onitr

onics

Inc

Napco MA1000E Program Sheet

------------------------------------------------< Misc Functions >--------------------------------------------------

To program sections 084 to 216 see below Diagram

Add location together and enter sum in location Example: Program Zones 1, 3 4, 5 and 6 for Door Chime 1. Press B/A then B/A again then 8 8 to enter Location 088 2. Add Zone 1 (1) + Zone 2 (2) + Zone 4 (8) = 11 or B, enter B in location 088 3. Press 2 key to move to 089 4. Add Zone 5 (1) + Zone 6 (2) = 3, enter 3 in location 089

Swinger Shutdown I__F__I__3__I (Swinger enabled on all Zones) 084 085 No EOL Zone Resistors I__ __I__ __I (F 3 = No EOL all Zones, Blank = EOL all zones) 086 087 Chime Zones 1 to 6 I__ __I__ __I (Turns on/off chimes per zone) 088 089 Never Arm I__ __I__ __I (Leave blank) 090 091 PIR Zone I__ __I__ __I (Program PIR zones here. also see 206 - 207) 092 093 Untimed Output to Lug E15 I__F__I__B _I__ __I__ __I (Normally not programmed) 096 097 098 099 Keypad Sounder on Alarm I__ __I__ __I (Leave blank) 164 165 Day Zone I__ __I__ __I (Leave blank) 186 187 Priority Zone W/Bypass I__ __I__ __I (Leave blank) 188 189 Priority Zone I__F__I__3__I (Default = F 3, leave alone) 190 191 Remove Auto-Bypass I__ __I__ __I (Leave blank) 192 193 Selective Bypass I__F__I__3__I (Default = F 3, leave alone) 194 195 Group Bypass I__?__I__?__I (Any zone here will bypass by B/A key twice) 196 197 24 Hr Protection I__ __I__8__I (Use if Hold-Up buttons on a zone) 198 199 Auto Reset I__F__I__D__I (Default = F D, leave alone) 200 201 Entry/Exit Delay 1 Zones I__?__I__?__I (Program which zones are Delay 1) 202 203 Entry/Exit Delay 2 Zones I__?__I__?__I (Program which zones are Delay 2) 204 205 Interior Follower Zones I__?__I__?__I (Program PIR zones here. also see 092 - 093) 206 207 Abort Delay per Zone I__ __I__ __I (Leave blank) 208 209 Burglary Output per Zone I__F__I__B__I (FB = Audible Keypad Panic, F3 = Silent) 210 211 Timed Negative Output I__ __I__ __I (Leave blank) 212 213 7ms Loop Response I__ __I__ __I (Leave blank) 214 215 50ms Loop Response I__ __I__ __I (Leave blank) 216 217

Created by Mark Leuck 02/02/2002 Monitronics International, Inc.

Page 5: Napco MA1000E Program Sheet - ALARMSUNLIMITEDINC MA1000E... · Property of Monitronics Inc Napco MA1000E Program Sheet Enter Program 1. Hold 8 key for 3 seconds, keypad will beep

Prop

erty

of M

onitr

onics

Inc

Napco MA1000E Program Sheet

------------------------------------------------< User Codes >-------------------------------------------------

Hostage/Duress Code I__9__I__9__I 304 305

User Program Code I__1__I__2__I__3__I__4__I__5__I__6__I 306 307 308 309 310 311 This allows customer to change User codes, leave at default

Installer/Dealer Code I__4__I__5__I__6__I__7__I__8__I__9__I 312 313 314 315 316 317

User Code 1 I__1__I__2__I__3__I__4__I User Code 2 I__ __I__ __I__ __I__ __I User Code 3 I__ __I__ __I__ __I__ __I 318 319 320 321 322 323 324 325 326 327 328 329 User Code 4 I__ __I__ __I__ __I__ __I User Code 5 I__ __I__ __I__ __I_ 7__I User Code 6 I__ __I__ __I__ __I__ __I 330 331 332 333 334 335 336 337 338 339 340 341 User Code 7 I__ __I__ __I__ __I__ __I User Code 8 I__ __I__ __I__ __I__ __I 342 343 344 345 346 347 348 349 User Codes can be 1, 2, 3 or 4 digits, If User Code 5 is Quick Arm program as 7, customer can Arm system by pressing 7, do NOT make it anything else or it will screw up other functions!

-------------------------------------------------< Misc Options >-------------------------------------------------

Add each section, place total in box (Example: 1 + 4 + 8 = 13 or "D") I__ __I = Blank Out with 5 key

I__4__I çç 1 = Display Day Zone/Reset I__2__I çç 1 = Audible Test on Arming 078 2 = Reserved 180 2 = Auto-Reset after Timeout 4 = User 5 Quick Arm 4 = Reserved 8 = User 5 Report as User 1 8 = Reserved

I__ __I çç 1 = User 5 Service Code I__5__I çç 1 = Pulsing Fire

079 2 = Disable Day Zone Report 181 2 = Disable Key 9 Reset Fire Zone 4 = Users 6,7,8 Report as 2,3,4 4 = Enable Keypad Tactical Beeps 8 = Reserved 8 = Reset Test Timer on any Alarm Report

I__1__I çç 1 = Disable Low Battery Display* I__6__I çç 1 = Disable Fault Find 080 2 = Reserved 182 2 = Enable Keypad Panic 4 = Disable Callback Download 4 = Enable Communicator Test 8 = Disable Function 6 Download 8 = Disable Bell Test

I__1__I çç 1 = Watch on With Group Bypass I__1__I çç 1 = Display any Bypass 081 2 = Chime On with Group Bypass 183 2 = Reserved 4 = Display Open Zones 4 = Inc Manl Bypass in Force Arm/Status 8 = Disable Display Bypass 8 = Keyswitch Input on Zone 5

I__D__I çç 1 = Enable Download w/Ans Machine I__6__I çç 1 = Enable User 8 to PGM Lug 082 2 = Reserved 236 2 = Enable PGM on E/E Delay 4 = Enable Keypad Fire Panic* 4 = Fail to Communicate on PGM Lug 8 = Enable Keypad Aux/Medical Panic* 8 = Keypad Sounder on PGM Lug

I__2__I çç 1 = Touchtone Dialing I__ __I çç 1 = Ground Start on PGM Lug 178 2 = Touchtone with Rotary Backup 237 2 = Armed LED on PGM Lug 4 = Backup Reporting 4 = Keypad Aux on PGM Lug 8 = Double Reporting 8 = Audio Verification on PGM Lug

I__1__I çç 1 = Opening after Alarm (see 070 to 077) *Panics only work if Jumper E on Keypad is cut 179 2 = Force Arm (Jumper E found at bottom left in back of Keypad) 4 = Status Report ** Panel tends to display low battery if siren sounds 8 = Split Report for any length of time

Created by Mark Leuck 02/02/2002 Monitronics International, Inc.

Page 6: Napco MA1000E Program Sheet - ALARMSUNLIMITEDINC MA1000E... · Property of Monitronics Inc Napco MA1000E Program Sheet Enter Program 1. Hold 8 key for 3 seconds, keypad will beep

Prop

erty

of M

onitr

onics

Inc

Napco MA1000E Program Sheet

-------------------------------------------------< System Times >-------------------------------------------------

Entry/Exit Times found by dividing desired time by 16 Enter 1st digit of resut in second box and 2nd digit of result in 1st box (wierd ain't it?)

Sensor Watch I__ _ _I__ __I (Leave both blank, not used) 094 095 Exit Delay I__C__I__3__I (60 seconds) 218 219 Entry Delay 1 I__E__I__1__I (30 seconds) 220 221 Entry Delay 2 I__E__I__1__I (30 seconds) 222 223 Burg Timeout I__6__I__ __I (6 minutes, leave 2nd entry blank) 224 225 Fire Timout I__F__I__ __I (Unlimited, leave 2nd entry blank) 228 229 Chime Duration I__4__I__ __I (1/2 second Chime, leave 2nd entry blank) 230 231 Abort Delay I__ __I__ __I (Leave both blank, not used) 232 233 Test Timer I__ __I__ __I (Leave both blank, not used) 250 251 Auto Download ID I__ __I__ __I (Leave both blank, not used) 252 253 Callback Select I__ __I (Leave blank, not used) 254

Created by Mark Leuck 02/02/2002 Monitronics International, Inc.

Page 7: Napco MA1000E Program Sheet - ALARMSUNLIMITEDINC MA1000E... · Property of Monitronics Inc Napco MA1000E Program Sheet Enter Program 1. Hold 8 key for 3 seconds, keypad will beep

Prop

erty

of M

onitr

onics

Inc

Napco MA1000E Program Sheet

Created by Mark Leuck 02/02/2002 Monitronics International, Inc.

Page 8: Napco MA1000E Program Sheet - ALARMSUNLIMITEDINC MA1000E... · Property of Monitronics Inc Napco MA1000E Program Sheet Enter Program 1. Hold 8 key for 3 seconds, keypad will beep

Prop

erty

of M

onitr

onics

Inc

Mon

itron

ics

Nap

co 1

000e

Qui

ck R

efer

ence

Gui

de

Mon

itorin

g an

d S

ervi

ce c

all 1

-800

-447

-923

9

Arm

ing

With

ST

AT

US

ligh

t ste

ady

ente

r U

ser

Cod

e, A

RM

ligh

t sho

uld

turn

on

indi

catin

g sy

stem

is a

rmed

If

disp

lay

show

s a

flash

ing

“P”

syst

em w

as a

rmed

with

a z

one

open

Dis

arm

ing

/ S

ilenc

ing

an A

larm

E

nter

4-d

igit

Cod

e If

sile

ncin

g al

arm

turn

off

sire

n w

ith U

ser

Cod

e th

en h

old

9 fo

r th

ree

seco

nds

to s

top

any

flash

ing

disp

lay

Inst

ant D

oors

B

efor

e or

afte

r ar

min

g sy

stem

pre

ss 4

for

3 se

cond

s S

TA

TU

S li

ght w

ill r

apid

ly fl

ash

and

all e

ntry

doo

rs w

ill n

ow b

e in

stan

t A

ll zo

nes

retu

rn to

nor

mal

whe

n sy

stem

is d

isar

med

.

Zon

e B

ypas

sing

P

ress

[B/A

] + Z

one

to b

ypas

s (1

to 6

), B

YP

AS

S li

ght w

ill tu

rn o

n, a

rm s

yste

m n

orm

ally

W

hen

syst

em is

dis

arm

ed a

ll by

pass

ed Z

ones

will

ret

urn

to n

orm

al.

Use

r C

odes

Pre

ss 8

for

3 se

cond

s (k

eypa

d w

ill b

eep)

E

nter

Use

r P

rogr

amm

ing

Cod

e (A

RM

, ST

AT

US

and

BY

PA

SS

ligh

ts fl

ash

and

keyp

ad r

apid

ly b

eeps

) E

nter

Use

r to

add

or

chan

ge (

1 to

8)

Ent

er n

ew 3

to 4

-dig

it U

ser

Cod

e W

hen

finis

hed

pres

s [B

/A] t

wic

e to

exi

t T

o er

ase

a co

de fo

llow

abo

ve s

teps

but

pre

ss [B

/A] t

wic

e in

stea

d of

ent

erin

g a

code

Doo

r C

him

es

Pre

ss 5

for

3 se

cond

s, r

epea

t thi

s to

turn

off

chim

es

Sm

oke

Det

ecto

r R

eset

S

ilenc

e si

ren

with

Use

r C

ode

Pre

ss 9

for

3 se

cond

s, s

mok

e de

tect

or s

houl

d re

set

Tro

uble

Lig

ht

With

any

inte

rnal

pro

blem

AR

M, S

TA

TU

S a

nd B

YP

AS

S li

ghts

will

flas

h an

d a

num

ber

will

app

ear

1 =

Pow

er F

ailu

re: S

yste

m is

ope

ratin

g on

Bac

kup

Bat

tery

2 =

Low

Bat

tery

: Bac

kup

Bat

tery

is lo

w a

nd n

eeds

to e

ither

rec

harg

e or

be

repl

aced

.

3

= F

ailu

re to

Com

mun

icat

e: S

yste

m c

anno

t com

mun

icat

e w

ith M

onito

ring

Sta

tion

Pan

ic B

utto

ns

Pre

ss 9

and

# fo

r F

ire, [

*/P

] and

# fo

r P

olic

e, [B

/A] a

nd #

for

Med

ical

N

ote:

You

may

hav

e to

arm

and

dis

arm

sys

tem

to tu

rn o

ff si

ren

afte

r us

ing

Pan

ic B

utto

ns

Created by Mark Leuck 02/02/2002 Monitronics International, Inc.