OVER/UNDER VOLTAGE PROTECTOR
NAH KIEN WAH
THIS DISSERTATION IS SUBMITTED IN PARTIAL FULFILMENT OF THE BACHELOR DEGREE IN SCIENCE WITH HONOURS
ýýýfýPERPItStt; luy! j jlTI ý,,, LAYSI, 7 S, 41,
PHYSICS WITH ELECTRONIC PROGRAMME SCHOOL OF SCIENCE AND TECNOLOGY
UNIVERSITI MALAYSIA SABAH
April 2008
UNIVERSITI MALAVSIA SABAH
JUDUL:
BORANG PENGESAHAN STATUS TESISn
ýVQr ` VyýýQ. r ýp`ý0. kQ. ýýOýQcýoc'
PUMS99: 1
ul SC1ý, N Cý wým -k-c 0 m0 VpS IJAZAH: w%- DA
SAYA IVýtý ýýN ýºýºýCýl ' (HURUF BESAR)
3 SESI PENGAJIAN:
ýf,
mengaku membenarkan tesis (LPSM/Sarjana/Doktor Falsafah) ini disimpan di Perpustakaan Universiti Malaysia Sabah dengan syarat-syarat kegunaan seperti berikut: -
1. Tesis adalah hakmilik Universiti Malaysia Sabah. 2. Perpustakaan Universiti Malaysia Sabah dibenarkan membuat salinan untuk tujuan pengajian
sahaja. 3. Perpustakaan dibenarkan membuat salinan tesis ini sebagai bahan pertukaran antara institutsi
pengajian tinggi. PERPUSTAK, tiAM 4. Si [a tandakan (/)I! 't"rt'SITI MAI AVC1I ýýýý.,
0 SULIT
TERHAD
ý TIDAK TERHAD I
(TANDATANGAN PENULIS)
lamat TetaD: B 1-1-V 1400 KawI Miw_
Tarikh: (0
LIBRA
(TANDATANGAN PU RUIM' LIBRARIAN
I (TANDATANGAN PU "
LAYJ
Tarikh:
Nama Penyelia
CATATAN: - "Potong yang tidak berkenaan. ""Jika tesis ini SULZT atau TERHAD, sila lampirkan surat daripada pihak berkuasa
/organisasi berkenaan dengan menyatakan sekali sebab dan tempoh tesis ini perlu dikelaskan sebagai SULIT dan TERHAD.
@Tesis dimaksudkan sebagai tesis bagi Ijazah Doktor Falsafah dan Sarjana secara penyelidikan atau disertai bagi pengajian secara kerja kursus dan Laporan Projck Sarjana Muda (LPSM).
--..... 1 1 9.31n ahtstin (Mengandungi maklumat yang berdarjah keselamatan atau Kepentingan Malaysia seperti yang termaktub di dalam AKTA RAHSIA RASMI 1972)
(Mengandungi maklumat TERHAD yang telah ditentukan oleh organisasi/badan di mana penyelidikan dijalankan)
Disahkan Oleh
NURULAIN BINT ISMAIL "
IÄ SABpN ý
I
DECLARATION
I verify that this project is my own work except some materials are taken from the
work of others, in which each case has been indicate its source.
5th Mei 2008
NAH KIEN WAH
HS2005-2652
APPROVAL OF EXAMINERS
APPROVED BY
Signature
1. SUPERVISOR
(Ms. Teh Mee Tenb)
2. EXAMINER I
(Associate Prof. Dr. Jedol Dayou)
3. EXAMINER 2
(Mr. Saafie Salleh)
4. DEAN
(Associate Prof. Dr. Shariff A. Kadir Omang)
S'., 5. og
ýyý., 'ý2
111
ACKNOWLEDGEMENT
I wish to express my appreciation to my supervisor, Ms Teh Mee Teng for her
motivation in leading me and other undergraduates in their final year project. She has
provided us with her knowledge and guides generously from time to time. I hereby
take this opportunity to express my gratitude for her continuous guidance and advices
throughout this project.
I would also like to extend my heartiest gratitude to all the lecturers in my
course for all their ideas and inspiration. Special appreciation also express to William
Ker and En. Rahim who willing to assist in provided all necessary instrument and
equipment to make the circuit success.
Finally, let me say thanks to my family members for their moral and finance
support.
ABSTRACT
Over/under voltage protector is designed particularly to overcome the over voltage
and under voltage events. It is sensitive enough to disconnect the power supply when
the input voltage is out of specific range. Various "over voltage" and "under voltage"
is created by using several steps down transformers. Secondary windings of
transformers are connected serially, and then its combination voltage measured will be
the sum of the output of each transformer. The circuit constructed is connected by the
voltage supply which is higher than household power supply (over voltage), hence
over voltage range can be determined. While the under voltage range is determined by
connecting the voltage supply which is lower than household power supply (under
voltage), to the circuit. Operational amplifier IC in the circuit compare its DC voltage
with corresponding zener diode, hence control the range of normal power supply
permitted in the over/under voltage protector. Over/under voltage protector is built
and its range of "voltage permitted" is set to 183.36 V to 262.00 V with uncertainty of
4.61% for over voltage edge and 1.86% for under voltage edge. However, the range of
the over voltage and under voltage still can be adjusted using variable resistor VRI
and VR2 respectively.
V
ABSTRAK
Pelindung voltan tinggi/rendah direka cipta untuk menangani masalah "voltan tinggi"
dan "voltan rendah". Alat ini adalah sensitif untuk memutuskan berkalan elektrik
daripada peralatan elektrikal, apabila berkalan voltan melebihi atau kurang daripada
julat yang ditentukan. Beberapa set "voltan tinggi" dan "voltan rendah" dicipta dengan
menggunakan beberapa transformer perendah. Output transformer disambung secara
seri, seterusnya voltan gabuangan yang didapati merupakan jumlah setiap output
transformer. Litar disambung kepada beberapa "voltan tinggi" yang lebih tinggi
daripada voltan perumahan, untuk menentukan had maksimum voltan tinggi yang
dibenarkan oleh pelindung voltan tinggi. Begitu juga dengan had minimum voltan
rendah, beberapa "voltan rendah" yang rendah daripada voltan perumahan disambung
kepada litar. Op-Amp IC dalam litar memainkan peranan dalam membandingkan
voltan DC yang melaluinya, seterusnya mengawal julat voltan biasa yang dibenarkan
oleh pelindung voltan tinggi/rendah. Pelindung voltan tinggi/rendah dibina dan julat
voltan yang dibenarkan ditentukan pada 183.36 V dan 262.00 V, dengan
ketidakpastian 4.61 % untuk sempadan voltan tinggi dan 1.86 % untuk sempadan
voltan rendah. Bagaimanapun, julat antara sempadan voltan tinggi dan voltan rendah
boleh diselaraskan dengan mengunakkan perintang pembolehubah, VRI dan VR2
masing-masing.
V1
CONTENTS
DECLARATION
APPROVAL
ACKNOWLEDGEMENT
ABSTRAC
ABSTRAK
LIST OF CONTENT
LIST OF TABLES
LIST OF FIGURES
LIST OF PHOTOS
LIST OF SYMBOLS
CHAPTER 1 INTRODUCTION
1.1 Background
1.2 Purpose of Project
1.3 Objective of Project
1.4 Scope of Project
1.5 Hypothesis
CHAPTER 2 LITERATURE REVIEW
2.1 Electrical Transmission and Distribution
2.1.1 Grounding System
2.1.2 Electrical Meter
Page
1
11
111
iv
V
vi
X
X1
Xlll
xiv
I
I
3
3
4
4
5
5
8
9
Vll
2.1.2. a Electromechanical Meter
2.1.2. b Electronic Meter
2.2 Safety Device
2.2.1 Fuse
2.2.2 Circuit Breaker
2.2.3 Surge Protector
2.2.4 Gas Discharge Arrestor
2.3 Overvoltage Protector
2.3.1 Crowbar Circuit
2.3.2 Series Connected Switch Circuit
2.4 Conversion from AC to DC
2.4.1 Half Wave Rectifier
2.4.2 Full Wave Rectifier
CHAPTER 3 METHODOLOGY
3.1 Introduction
3.2 Material and Instrument
3.2.1 Soldering Iron
3.2.2 Lead Solder
3.2.3 Soldering Sucker
3.2.4 Digital Multimeter
3.2.5 Transformer
3.2.6 Relay
3.2.7 Variable Resistor
10
11
12
14
15
17
19
20
21
23
24
24
25
27
27
28
28
29
29
30
31
31
32
viii
3.2.8 Op-amp LM324
3.2.9 Regulator IC 7812
3.3 Construction of Circuit
3.3.1 Schematic Circuit Diagram
3.3.1. a Original Circuit
3.3.1. b Modify Circuit
3.3.2 Procedures of Circuit's Construction
3.4 Protection Experiment
3.4.1 Over Voltage
3.4.1. a Formation of Over Voltage
3.4.1. b Measurement of Secondary Voltage
with "Over Voltage" Input 3.4.1. c Determination of Over Voltage
Range
3.4.2 Under Voltage
3.4.2. a Formation of Under Voltage
3.4.2. b Measurement of Secondary Voltage
with "Under Voltage" Input
3.4.2. c Determination of Under Voltage
Range
33
34
35
35
35
37
38
41
41
41
42
43
44
44
45
46
ix
CHAPTER 4 RESULTS AND DISCUSSION
4.1 Introduction
4.2 Formation of Testing Voltage
4.3 Measurement of Secondary Voltage of Main
Transformer with Primary Testing Voltage
4.4 Determination of Over/Under Voltage Range
4.41 Over Voltage
4.42 Under Voltage
CHAPTER 5 CONCLUSION
5.1 Conclusion
5.2 Future Research
48
48
49
53
56
56
58
63
63
64
REFERENCE 65
X
LIST OF TABLES
Table No.
2.1 Sizes of tinned copper wire fuse elements
3.1 Formation of "Over Voltage"
3.2 Secondary Voltage of Main Transformer with
"Over Voltage" Input
3.3 DC Voltage of Pin 3 with Respond of Relay
3.4 Formation of "Under Voltage"
3.5 Secondary Voltage of Main Transformer with
"Under Voltage" Input
3.6 DC Voltage of Pin 6 with Respond of Relay
4.1 Formation of "Over Voltage"
4.2 Formation of "Under Voltage"
4.3 Deviation between Theoretical and Actual
Reading
4.4 Secondary Voltage of Main Transformer with "Over Voltage" Input
4.5 Secondary Voltage of Main Transformer with "Under Voltage" Input
4.6 Turns ratio of Main Transformer
4.7 Voltage at Pin 3 and Respond of Relay at 6.5 k S2
4.8 Voltage at Pin 3 and Respond of Relay at 3.8 k 12
4.9 Voltage at Pin 6 and Respond of Relay at 4.3 k C)
4.10 Voltage at Pin 6 and Respond of Relay at 2.6 k S2
Page
15
42
43
44
45
46
47
49
49
50
53
53
55
56
56
58
58
xi
LIST OF FIGURES
Figure No.
2.1 Electrical Power Transmissions and Distribution
2.2 Wiring Orientation of Transformer to Household
Power Supply
2.3 Single Stator Electromechanical Meter
2.4 Fuse
2.5 Circuit Breaker
2.6 Internal Design and Structure of Circuit Breaker
2.7 Surge Protector
2.8 Simple MOV Surge Protector with Line
Conditioning and a Fuse
2.9 Gas Discharge Arrestor
2.10 Crowbar Circuit
2.11 Series Protector for Over/Under Voltage
2.12 Basic Circuit for Half Wave Rectifier
2.13 Input and Output Voltage Waveforms for the Half
Wave Circuit
2.14 Basic Circuit for Full Wave Rectifier
2.15 Input and Output Voltage Waveforms for the Full
Wave Circuit
Page
7
8
10
14
16
16
17
18
19
21
23
25
25
26
26
X11
3.1 SPDT Relay
3.2 Pin Connection Diagram of LM 324
3.3 Voltage Regulator 7812
3.4 Original Circuit without Op-amp IC and Transistor
32
33
34
35
3.5 Schematic Diagram of Modify Circuit 37
X111
LIST OF PHOTOS
Photo No.
3.1 Soldering Iron with Stand
3.2 Lead Solder
3.3 Sucker
3.4 PeakTech®3140 Digital Multimeter
3.5 Transformer
3.6 Preset
3.7 Op-amp LM324
3.8 Modified Circuit on Strip Board
4.1 Formation of Testing Voltage
4.2 Over/under voltage protector under normal power
supply (183.36 V- 262.00 V)
4.3 Over/under voltage protector out of normal voltage
range (less than 183.36 V or more than 262.00 V)
Page
29
29
30
30
31
32
33
40
52
62
62
xiv
fIr
Hz
w
A
V W
S2
TTL
MOSFET
rms
LIST OF SYMBLOS
operating frequency
Hertz
angular Velocity
ampere
volt
watt
ohm
transistor-transistor logic
metal oxide semiconductor field transistor
root mean sq
CHAPTER 1
INTRODUCTION
1.1 Background
Electronic components have been designed to function properly when used within
their specified current and voltage ratings. When these ratings are exceeded during
operation, or known as over voltage, the component may sustain permanent damage
and the equipment may cease to operate. The conditions may be hazardous.
Depending on its duration, the over voltage events can be permanent or transient, the
latter case also being known as a voltage spike.
A more common scene of over voltage or over current is the operation of high-
power electrical devices such as air conditioners and refrigerators. These high-
powered pieces of equipment require a lot of energy to switch on and turn off
components like compressors and motors. This switching creates sudden, brief
demands for power, which upset the steady voltage flow in the electrical system.
While these surges are much less than the intensity of a lightning surge, they can be
severe enough to damage components, immediately or gradually, and they occur
regularly in most building's electrical systems.
1
I
2
Over voltage of power supply occur when something boosts the electrical
charge at some point in the power lines. This causes an increase in the electrical
potential energy, which can increase the current flowing to the wall outlet. When the
increase lasts three nanoseconds (billionths of a second) or more, it is called a surge.
While when it only lasts for one or two nanoseconds, it's called a spike. A number of
different things can cause this to happen.
The major source of the over voltage event are lightning strikes. When
lightning strikes near a power line, whether it's underground, in a building or running
along poles, the electrical energy can boost electrical pressure by millions of volts.
This causes an extremely large power surge that will overpower almost any over
voltage protector. In a lightning storm, sometime the best protection is to unplug their
electrical devices. However, these occurrences are always unexpected.
Other sources of over voltage are power outage, malfunction of electricity
supplier, and overload current that will cause the wire to melt, resulting short circuit
of electrical appliances.
In normal household and office wiring in our country, the standard voltage is
approximately 240 volts. If the voltage rises extremely beyond standard voltage, there
is a problem, and the over/under voltage protector helps to prevent that problem from
destroying our electrical appliances. Although under voltage condition is more rarely
to occur, and the occurrence does not bring any serious damage to the electrical
appliances, but once we know the faulty is caused by insufficient of voltage supply,
the proper maintenance and checking could be done shortly. Thus, unexpected
3
expense to repair and purchase new set could be avoided, given over/under voltage
protector is used.
1.2 Purpose of Project
The purpose of the project is to construct an over/under voltage protector to prevent
the electrical appliance from serious damage due to over or under voltage events.
1.3 Objective of Project
The objectives of the project are:
" To develop a circuit that could protect the electrical appliance against over or
under voltage events.
" To determine the exact range of normal voltage between over voltage edge
and under voltage edge, which is permitted by over/under voltage protector.
4
1.4 Scope of Project
The scope of the project is to build a circuit that responds to the transient voltage,
either exceeds 250 volts or less than 180 volts (approximately), the power supply will
disconnect immediately. The power supply will still connected to the appliance if the
voltage falls within 180 volts and 250 volts (approximately).
1.5 Hypothesis
The circuit developed is able to detect the over voltage and under voltage, hence
disconnect the power supply from the load.
CHAPTER 2
LITERATURE REVIEW
2.1 Electrical Transmission and Distribution
The electrical transmission system is the interconnection of the electric energy
produced by power plants with the loads. The operating frequency (fop) is 50 Hz in
our country. At the power station, an electrical generator converts mechanical power
into a set of alternating electric currents. The currents are sinusoidal functions of time,
all at the same frequency but offset in time to give different phases. In a three-phase
system, the phases are spaced equally, giving a phase separation of one-third cycle.
(Karady, G. G., 2006)
The three-phase power leaves the generator and enters a transmission
substation at the power plant. This substation uses large transformers to convert the
generator's voltage (which is at the thousands of volts level) up to extremely high
voltages for long-distance transmission on the transmission grid.
6
For power to be useful in a home or business, it comes off the transmission
grid and is stepped-down to the distribution grid. This may happen in several phases.
The place where the conversion from "transmission" to "distribution" occurs is in a
power substation. A power substation typically does several things:
" It has transformers that step transmission voltages (in the tens or hundreds of
thousands of volts range) down to distribution voltages (typically less than 10,000
volts).
" It has a "bus" that can split the distribution power off in multiple directions.
" It often has circuit breakers and switches so that the substation can be
disconnected from the transmission grid or separate distribution lines can be
disconnected from the substation when necessary.
After that, the power goes from the transformer to the distribution bus. The
bus distributes power to two separate sets of distribution lines at two different
voltages. The smaller transformers attached to the bus are stepping the power down to
standard line voltage (usually 7,200 volts) for one set of lines, while power leaves in
the other direction at the higher voltage of the main transformer. The wires at the
higher voltage need to be stepped down again, which will often happen at another
substation or in small transformers somewhere down the line. (Gonen, T., 1994)
After numerous further conversions in the transmission and distribution
network the power is finally transformed to the transformer drum, which is attached to
the pole. It reduces the 7,200 volts down to the 240 volts that makes up normal
7
household electrical service. There are two wires running out of the transformer and
three wires running to the house.
Figure 2.1 Electrical Power Transmissions and Distribution (Karady, G. G., 2006)
The two from the transformer are insulated, and the third one is bare. The bare
wire is the ground wire. The two insulated wires each carry 120 volts, but they are
180 degrees out of phase so the difference between them is 240 volts. The transformer
is wired in this sort of configuration (www. howstuffwork. com):
8
7,200 volts
ThT111Th rk i I
r L.
'_ 320 vows voww
240 voib
120 volts
Figure 2.2 Wiring of Transformer to Household Power Supply (Gonen, T., 1994)
2.1.1 Grounding System
In electricity supply systems, a grounding system defines the electrical potential of the
conductors relative to that of the Earth's conductive surface. Grounding system has
implications for the safety and electromagnetic compatibility of the power supply.
The grounding wire is directly or indirectly connected to one or more earth
electrodes. These may be located locally, be far away in the suppliers network or in
many cases both. This grounding wire is usually but not always connected to the
neutral wire at some point and they may even share a cable for part of the system
under some conditions. The ground wire is also usually bonded to pipe work to keep it
at the same potential as the electrical ground during a fault. Water supply pipes often
used to be used as ground electrodes.
A power ground serves to provide a return path for fault currents and therefore
allows the fuse or breaker to disconnect the circuit. The power ground is also often
bonded to the house's incoming pipe work, and pipes and cables entering the
65
REFERENCE
Brown, M., 2001, Power Supply Cookbook, Second Edition, Newnes, Butterworth-
Heinemann.
Crowell, B., 1999, Electricity and Magnetism, Edition 2.0. Fullerton, California.
Departments of the Army, and the Air Force, February 1995, Electrical Power
Supply and Distribution, TM 5-811-1/AFJMAN 32-1080, Washington, DC.
Fergusan, B., 2002, OVER VOLTAGE PROTECTION ON AC ADAPTER LNPUT,
Microsemi, Integrated Products.
Gheorghe, A. V., 2006, Critical Infrastructures at Risk, Securing the European
Electric Power System, Springer, Netherlands.
Halliday D., Resnick R., Walker J., 2001, Fundamental of Physics: the Sixth
Edition, John Wiley & Sons Inc, New York.
Rajashekara, K., Sohail Anwar, Barkhordarian, V., Alex, Q. I-I., Power Electronic
Devices, 2002, CRC Press LLC.