nabersnz ™ - one year on?
DESCRIPTION
NABERSNZ ™ - One year on?. Vanessa McGrath – NZGBC Lance Jimmieson - Jackson Engineering Advisers. Agenda. Where did NABERSNZ come from? The benefit of hindsight The introduction and growth of NABERSNZ Understanding NABERSNZ How NABERSNZ relates to Facility Managers - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: NABERSNZ ™ - One year on?](https://reader035.vdocuments.us/reader035/viewer/2022062323/5681673d550346895ddbeeee/html5/thumbnails/1.jpg)
NABERSNZ™ - One year on?
Vanessa McGrath – NZGBC
Lance Jimmieson - Jackson Engineering Advisers
1
![Page 2: NABERSNZ ™ - One year on?](https://reader035.vdocuments.us/reader035/viewer/2022062323/5681673d550346895ddbeeee/html5/thumbnails/2.jpg)
Agenda
• Where did NABERSNZ come from?
• The benefit of hindsight
• The introduction and growth of NABERSNZ
• Understanding NABERSNZ
• How NABERSNZ relates to Facility Managers
• How to maximise your building
• Next steps
2
![Page 3: NABERSNZ ™ - One year on?](https://reader035.vdocuments.us/reader035/viewer/2022062323/5681673d550346895ddbeeee/html5/thumbnails/3.jpg)
National Australian Built Environment Rating System (NABERS)
3
Australian History & Results
![Page 4: NABERSNZ ™ - One year on?](https://reader035.vdocuments.us/reader035/viewer/2022062323/5681673d550346895ddbeeee/html5/thumbnails/4.jpg)
Aussie Rules
Nov 2001: Mandated in Australia2,000 m2 + buildings must disclose a current Building Energy Efficiency Certificate (BEEC).
4
![Page 5: NABERSNZ ™ - One year on?](https://reader035.vdocuments.us/reader035/viewer/2022062323/5681673d550346895ddbeeee/html5/thumbnails/5.jpg)
Property Council Australia - Quality Grading
5
![Page 6: NABERSNZ ™ - One year on?](https://reader035.vdocuments.us/reader035/viewer/2022062323/5681673d550346895ddbeeee/html5/thumbnails/6.jpg)
NABERS in Australia
6
![Page 7: NABERSNZ ™ - One year on?](https://reader035.vdocuments.us/reader035/viewer/2022062323/5681673d550346895ddbeeee/html5/thumbnails/7.jpg)
The impact on the Property Market
7
![Page 8: NABERSNZ ™ - One year on?](https://reader035.vdocuments.us/reader035/viewer/2022062323/5681673d550346895ddbeeee/html5/thumbnails/8.jpg)
NABERSNZ - Introduction
• Existing building performance rating system
• Energy performance benchmarking
• Compare energy efficiency of commercial office buildings
Range: 0 to 6 Stars
• Three types of ratings
8
![Page 9: NABERSNZ ™ - One year on?](https://reader035.vdocuments.us/reader035/viewer/2022062323/5681673d550346895ddbeeee/html5/thumbnails/9.jpg)
NABERSNZ - Philosophy:
To compare apples with apples
Make allowances for:
• Climate
• Hours of operation
• Core service delivery functions
Standardised methodology
9
![Page 10: NABERSNZ ™ - One year on?](https://reader035.vdocuments.us/reader035/viewer/2022062323/5681673d550346895ddbeeee/html5/thumbnails/10.jpg)
NABERSNZ - Progress to date
• Pilot training & assessments February 2013
• Official Launch June 2013
• 12 Certified Ratings (Published)
• 352 Self Assessments
• 175,579m² of commercial office space has undergone a Certified Rating thus far
10
![Page 11: NABERSNZ ™ - One year on?](https://reader035.vdocuments.us/reader035/viewer/2022062323/5681673d550346895ddbeeee/html5/thumbnails/11.jpg)
NABERSNZ - Results(m2 Rated)
11
![Page 12: NABERSNZ ™ - One year on?](https://reader035.vdocuments.us/reader035/viewer/2022062323/5681673d550346895ddbeeee/html5/thumbnails/12.jpg)
NABERSNZ Rules
Energy Loads
12
![Page 13: NABERSNZ ™ - One year on?](https://reader035.vdocuments.us/reader035/viewer/2022062323/5681673d550346895ddbeeee/html5/thumbnails/13.jpg)
What does NABERSNZ rate?
Rating type Covers Applicable to:
Tenancy Lighting and plug loads used within the tenancy space
Tenants
Base Building Common-area lighting and power, lifts, HVAC to the whole building
Building owner or property manager
Whole Building A combination of the above
Building owner or property manager
13
![Page 14: NABERSNZ ™ - One year on?](https://reader035.vdocuments.us/reader035/viewer/2022062323/5681673d550346895ddbeeee/html5/thumbnails/14.jpg)
Tenant loadsPower and Lighting to Tenancy rentable area Power and
Lighting to Tenancy service areas assigned to a single tenant
Tenant-controlled supplementary air conditioning to meet a special tenant requirement
Generator fuel for a tenant
Tenant-installed signage within or on the building
14
![Page 15: NABERSNZ ™ - One year on?](https://reader035.vdocuments.us/reader035/viewer/2022062323/5681673d550346895ddbeeee/html5/thumbnails/15.jpg)
Base building loadsCentral plant i.e. chillers, boilers, AHUs
Centralised supplementary services provided for tenantsLifts &
escalators
Toilet exhaust fan
Exterior lighting
Lighting and power in common areas
Exterior signage
Generator fuel where it serves central services
Car park ventilation and lighting for tenant use
HVAC to meet normal office needs
HVAC to meet normal office requirements
Automatic blinds to control internal temperature
15
![Page 16: NABERSNZ ™ - One year on?](https://reader035.vdocuments.us/reader035/viewer/2022062323/5681673d550346895ddbeeee/html5/thumbnails/16.jpg)
Data Required
• Survey plans measured to PCNZ standard
• Leases, BMS records, after hour records, occupancy surveys
• Computer count
• Utility bills, check meter readings, diesel delivery bills
16
![Page 17: NABERSNZ ™ - One year on?](https://reader035.vdocuments.us/reader035/viewer/2022062323/5681673d550346895ddbeeee/html5/thumbnails/17.jpg)
First time is always the hardest
Major challenges:
• Lack of adequate metering
• NLA surveys
• Lack of up to date single line diagrams
• Need for retro-commissioning
17
![Page 18: NABERSNZ ™ - One year on?](https://reader035.vdocuments.us/reader035/viewer/2022062323/5681673d550346895ddbeeee/html5/thumbnails/18.jpg)
Facilities Managers Influence
Measure NABERS impact
Partially in-sourced building management
1.3 Stars
Where building, asset and portfolio manager all feel able to affect efficiency
0.9 Stars
Efficiency penalties/incentives to maintenance Contractors
0.4 Stars
18
![Page 19: NABERSNZ ™ - One year on?](https://reader035.vdocuments.us/reader035/viewer/2022062323/5681673d550346895ddbeeee/html5/thumbnails/19.jpg)
Facilities Managers Skills
Measure NABERS impact
Efficiency training program in place
0.5 Stars
Where facilities manager reports a higher level of energy efficiency knowledge perform better
1.3 Stars
19
![Page 20: NABERSNZ ™ - One year on?](https://reader035.vdocuments.us/reader035/viewer/2022062323/5681673d550346895ddbeeee/html5/thumbnails/20.jpg)
Energy Efficiency Consideration
• Part Load (pumps, fans, chillers, boilers, etc.)
• After-hours strategy (base building system)
• Economy cycle
• Re-heat and humidity control
• Allowing for a single-tenant or a multiple tenants
20
![Page 21: NABERSNZ ™ - One year on?](https://reader035.vdocuments.us/reader035/viewer/2022062323/5681673d550346895ddbeeee/html5/thumbnails/21.jpg)
Next steps
• Is your building NABERSNZ ready? Find out
• Enabling works?
• First certified rating- can remain private
• Focus on the journey
• Energy efficiency improvement plan
• Engagement from tenants, property owners etc.
21
![Page 22: NABERSNZ ™ - One year on?](https://reader035.vdocuments.us/reader035/viewer/2022062323/5681673d550346895ddbeeee/html5/thumbnails/22.jpg)
Education options
NABERSNZ Practitioner course• A basic knowledge of the Rules, the data
required, metering requirements, common problems in existing buildings. Access to the reverse calculator
NABERSNZ Assessor course• Carry out NABERSNZ Certified Ratings• Access to the rating tool
22
![Page 23: NABERSNZ ™ - One year on?](https://reader035.vdocuments.us/reader035/viewer/2022062323/5681673d550346895ddbeeee/html5/thumbnails/23.jpg)
Questions?
• You can contact the NABERSNZ Team at the New Zealand Green Building Council:Email: [email protected]: www.nzgbc.org.nz
• For further information on NABERSNZ visit:www.nabersnz.govt.nz
• For more information on how your organisation can improve your energy efficiency visit:www.eecabusiness.govt.nz
23