na vli scale data sheet picture gallery of typical units...weld socket 1" data sheet: 66.01d...
TRANSCRIPT
![Page 1: na VLI scale data sheet Picture gallery of typical units...weld socket 1" Data Sheet: 66.01D Operating Conditions HELP@controlcomponents.com.au Made under licence by: Ph: +61 (0)2](https://reader034.vdocuments.us/reader034/viewer/2022050413/5f89895db71ad0308166ed78/html5/thumbnails/1.jpg)
Control Components Pty LtdABN 24 080 175 293
PO Box 212Caringbah NSW 1495Sydney Australiaph: +61 (0)2 9542 8977fx: +61 (0)2 9542 [email protected]
IndicatorModel
DrawingNumber Description Material
66.01 66000 Overview
66000A 66.01A Side flanged connection
66000F 66.01F Top & bottom flanged connections
66000D 66.01D Side socket connections
66000DI 66.01DI Side socket connections - Inverted layout
66000E 66.01E Single side connection and vented top
66000DEI 66.01DEI Side socket & vented top - Inverted layout
All na VLI scale data sheet
All na Picture gallery of typical units
Click on the drawing number (blue) to go direct to sheet
Magnetic Visual Level Indicators made in Australia under licence to Weka AG of Switzerland.
Engineered Plastics
66000A, BI, C, D & E Rev 6 Website May 13
![Page 2: na VLI scale data sheet Picture gallery of typical units...weld socket 1" Data Sheet: 66.01D Operating Conditions HELP@controlcomponents.com.au Made under licence by: Ph: +61 (0)2](https://reader034.vdocuments.us/reader034/viewer/2022050413/5f89895db71ad0308166ed78/html5/thumbnails/2.jpg)
66000A
Media max 600cst
Density min 0.65 g/cm3
Pressure / Temperature Material dependent
Operating pressure max 10 bar @ 20 oC
Design pressure max 10 bar @ 20 oC
Operating temperature -30oC to + 70oC
Design temperature -30oC to + 70oC
Test pressure:
Indicating RailPolycarbonate / Al flags: Red (std), Yellow, Blue (700C max)Polyolefin protection: Heat shrink protection tubing
MaterialsFloat chamber PVC-U, PVC-C, PVDF, ABSFloat model: PTFE, 316SS - PVDF, PVC
Gaskets / seals: EPDM or Viton
Backing rings: Vanstone, SS or Galv MS
Solvent / Cement: Tangit (Std) or DYTEX / IPS724
DimensionsConnection distance 'L' dimension (mm between centres)
ConnectionsType 66000Flange standard: ANSI (B16.5), BS (AS2129)
Flange size: NB 15, 20, 25, 32, 40, 50
Class / rating: Class150, D/E
Flange facing: Flat - Vanstone or Backing rings
Optional (at extra cost)
Top, bottom flange: ANSI (B16.5), BS (AS2129)
Drain: 1/2" BSP, M or F
Vent: 1/2" BSP, M or F
Vent /drain valves: Ball valves. EPDM / Viton seals
Isolation valves. EPDM / Viton seals
AccessoriesMagnetic switches: Qty:
Transmitter: Control range mm:
Special RequirementsInstrument tags (20x40mm of 316SS)
Support bracket (1 standard for lengths over 2m)
Support frame 316 SS / Alum. Details below.
Measuring Scale Details below.
Safe Fill Sign kitsInverted layout
Process gaskets - not normally supplied
66000E 66000DEIMade under licence by:Control Components Pty LtdPh: +61 (0)2 9542 8977 Fx: +61 (0)2 9542 [email protected]
66000 NB50 plastic series Data Sheet: 66.01
Technical Data
Magnetic Level Indicator
66000DI 66000F
'L'
Dim
ensi
on (
mm
) b
etw
een
cent
res
'L'
Dim
ensi
on (
mm
)
bet
we
en c
entr
es
'L'
Dim
en
sion
(m
m)
200 - 270mmmedia SGdependant
~200mm
'L'
Dim
ensi
on (
mm
) b
etw
een
cent
res
~130mm
150m
m M
in *
NB50
150
mm
Min
'L'
Dim
ensi
on (
mm
) b
etw
een
cent
res
~130mm
150
mm
Min
*
NB50
N B50 d oub lesocket un ion
53.5 mm
12.0 mm
12.0 mm
66000A, BI, C, D & E Rev 6 Website May 13
![Page 3: na VLI scale data sheet Picture gallery of typical units...weld socket 1" Data Sheet: 66.01D Operating Conditions HELP@controlcomponents.com.au Made under licence by: Ph: +61 (0)2](https://reader034.vdocuments.us/reader034/viewer/2022050413/5f89895db71ad0308166ed78/html5/thumbnails/3.jpg)
Media max 600cst
Density min 0.65 g/cm3
Pressure / Temperature Material dependent
Operating pressure max 10 bar @ 20 oC barDesign pressure max 10 bar @ 20 oC bar
Operating temperature -30oC to + 70oC OC
Design temperature -30oC to + 70oC OC
Test pressure: bar
Indicating RailPolycarbonate / Al flags: Red (std), Yellow, Blue (700C max)
Polyolefin protection: Heat shrink protection tubing
Materials
Float chamber PVC-U, PVC-C, PP, PVDF, ABSFloat model: PTFE, PVDF, PVC, 316SS
Gaskets / seals:
Backing rings: (Galv MS standard)
Solvent / Cement: Tangit (Std) or DYTEX / IPS724
DimensionsConnection distance 'L' dimension (mm between centres) mm
Drop leg length from centreline of lower connection: mm
ConnectionsType 66000A 2 side connecting flanges
Flange standard: ANSI (B16.5), BS (AS2129)Flange size: NB 15, 20, 25, 32, 40, 50 mmClass / rating: Class150, D/E
Flange facing: Flat
Optional (at extra cost)
Top, bottom flange: ANSI (B16.5), BS (AS2129)
Drain: 1/2" BSP, M or F
Vent: 1/2" BSP, M or F
Vent /drain valves: Ball valves. EPDM / Viton seals
Isolation valves. EPDM / Viton seals
Rev AccessoriesMagnetic switches: Qty: Model:
Transmitter: Control range mm: Model:
Special Requirements
Instrument tags (20x40mm of 316SS)
Support bracket (1 standard for lengths over 2m)
Support frame 316 SS / Alum. Details below.
Measuring Scale Details below.
Notes
Control Components Pty Ltd
Factory use only:
Mnfr Date:
CCPL Invoice:
Serial Number:
CCPLQuote:
66000ASide flanged connections
Technical Data
Magnetic Level Indicator
Quantity:
Customer:
CustomerPO & Date:
Made under licence by:
Ph: +61 (0)2 9542 8977 Fx: +61 (0)2 9542 7978
Data Sheet: 66.01A
Operating Conditions
'L'
Dim
ensi
on (
mm
) b
etw
een
cent
res
~130mm
* Vent & drain fittings may extend these dimensions.
150m
m M
in *
NB50
150m
m M
in
66000A, BI, C, D & E Rev 6 Website May 13
![Page 4: na VLI scale data sheet Picture gallery of typical units...weld socket 1" Data Sheet: 66.01D Operating Conditions HELP@controlcomponents.com.au Made under licence by: Ph: +61 (0)2](https://reader034.vdocuments.us/reader034/viewer/2022050413/5f89895db71ad0308166ed78/html5/thumbnails/4.jpg)
Rev # 0
Media: Rail colour: 0 T / B 0
SG: Poly: 0 Drain 0
Float: 0 0 Gaskets: 0 Vent 0 Manfr Date: 0
Support
Bracket (s)0
Frame
0
Bkg/ Rings0
1. Compared with order: 3. Dimensions:
Serial No: Type: Centre to centre ('L' dimension)L' Dim: Connections: Flanges DN & PNOp Press: Op Temp: Flange Standard & facing
Alignment of flanges:2. Components: Drop leg length:
Indicator rail colour:Guide tape installed: 4. Chamber style:
Polyolefin protection tubing: Top & bottom fittings
Float type & material: Drain
Magnet level for SG: mm VentBacking rings:Support brackets: 5. Functional tests:
Support frame: Indicator rail:Accessories fitted: Switches:
Transmitter:
Made under licence by:Control Components Pty LtdPh: +61 (0)2 9542 8977 Fx: +61 (0)2 9542 7978
Manufacturing Test Report Serial Number: 0
Magnetic Level Indicator
Customer: 0 Type: 66000A
Customer PO & Date:
0
0Quantity: 0
0.000
0 'L' Dim:
Pressure (bar) Temperature (OC) Flange connections
0 0 0 0
FacingStandardDesign
Pressure:
0 0 0
Pressure(bar)
0
0
Notes
Pressure Test
NO
Air / Immersionpressure test:
NOTime(mins)
PASS
Water pressure test:Withfloat:
___________________________ _____________________________________
Final Inspection / Acceptance Tests / Checklist
Comments
We certify that the above magnetic level indicator(s) was tested as shown and accepted as complying with the customer order, as received by Control Components Pty Ltd.
DateTest conducted by
_____________________________________
Signed as correct
_________________
Operating Temp:
Maximum
Signed as correct
Operating Pressure:
Switches Accessories
Qty: 0 Model: 0 0
CCPL Invoice: 0
Solvent / Cement:0
Controlrange mm:
Transmitter
Model:
Size (NB) Class/Table
0
66000A, BI, C, D & E Rev 6 Website May 13
![Page 5: na VLI scale data sheet Picture gallery of typical units...weld socket 1" Data Sheet: 66.01D Operating Conditions HELP@controlcomponents.com.au Made under licence by: Ph: +61 (0)2](https://reader034.vdocuments.us/reader034/viewer/2022050413/5f89895db71ad0308166ed78/html5/thumbnails/5.jpg)
Media max 600cst
Density min 0.65 g/cm3
Pressure / Temperature Material dependent
Operating pressure max 10 bar @ 20 oC barDesign pressure max 10 bar @ 20 oC bar
Operating temperature -30oC to + 70oC OC
Design temperature -30oC to + 70oC OC
Test pressure: bar
Indicating RailPolycarbonate / Al flags: Red (std), Yellow, Blue (700C max)
Polyolefin protection: Heat shrink protection tubing
Materials
Float chamber PVC-U, PVC-C, PP, PVDF, ABS
Float model: PTFE, PVDF, PVC, 316SS
Gaskets / Seals:
Solvent / Cement: Tangit (Std) or DYTEX / IPS724
DimensionsConnection distance 'L' dimension (mm face to face) mm
Dead zone (no indication) at bottom of chamber mm
ConnectionsType 66000F Top & bottom flanged
Flange standard: ANSI (B16.5), BS (AS2129)Flange size: NB50 mmClass / rating: Class150, D/E
Flange facing: Flat
Optional (at extra cost)
Full face flanges
Backing rings Gal MS or 316SS
Stub flanges with backing rings
Rev AccessoriesMagnetic switches: Qty: Model:
Transmitter: Control range mm: Model:
Special Requirements
Instrument tags (20x40mm of 316SS)
Support bracket (1 standard for lengths over 2m)
Support frame 316 SS / Alum. Details below.
Measuring Scale Details below.
Notes
Control Components Pty Ltd
Data Sheet: 66.01F
Operating Conditions
CustomerPO & Date:
Made under licence by:
Ph: +61 (0)2 9542 8977 Fx: +61 (0)2 9542 7978
66000FSide flanged connections
Technical Data
Magnetic Level Indicator
Quantity:
CCPLQuote:
Customer:
Mnfr Date:
CCPL Invoice:
Factory use only:
Serial Number:
'L'
Dim
ensi
on (
mm
) b
etw
een
cent
res
66000A, BI, C, D & E Rev 6 Website May 13
![Page 6: na VLI scale data sheet Picture gallery of typical units...weld socket 1" Data Sheet: 66.01D Operating Conditions HELP@controlcomponents.com.au Made under licence by: Ph: +61 (0)2](https://reader034.vdocuments.us/reader034/viewer/2022050413/5f89895db71ad0308166ed78/html5/thumbnails/6.jpg)
Media max 600cst
Density min 0.65 g/cm3
Pressure / Temperature Material dependent
Operating pressure max 10 bar @ 20 oC barDesign pressure max 10 bar @ 20 oC bar
Operating temperature -30oC to + 70oC OC
Design temperature -30oC to + 70oC OC
Test pressure: bar
Indicating RailPolycarbonate / Al flags: Red (std), Yellow, Blue (700C max)
Polyolefin protection: Heat shrink protection tubing
MaterialsFloat chamber PVC-U, PVC-C, PP, PVDF, ABS
Float model: PTFE, PVDF, PVC, 316SSGaskets / Seals:Solvent / Cement: Tangit (Std) or DYTEX / IPS724
DimensionsConnection distance 'L' dimension (mm between centres) mm
Drop leg length from centreline of lower connection: mm
ConnectionsType 66000D 2 side connection sockets
Upper fitting: size:
Lower fitting: size:
Bottom access flange 2" ANSI (std), Table E (AS2129)
Optional (at extra cost)
Top access flange 2" ANSI (std), Table E (AS2129)
Drain: 1/2" BSP port with plug
Vent: 1/2" BSP port with plugVent /drain valves: Ball valves. EPDM / Viton sealsIsolation valves. EPDM / Viton seals
Rev AccessoriesMagnetic switches: Qty: Model:
Transmitter: Control range mm: Model:
Special RequirementsInstrument tags (20x40mm of 316SS)
Support bracket (1 standard for lengths over 2m)
Support frame 316 SS / Alum. Details below.
Measuring Scale Details below.
Notes
Control Components Pty Ltd
ANSI cl150 Vanstone flange
yes1/2"1/2"
weld socket1"
Data Sheet: 66.01D
Operating Conditions
Made under licence by:
Ph: +61 (0)2 9542 8977 Fx: +61 (0)2 9542 7978
66000DSide socket connections
Technical Data
Magnetic Level Indicator
Factory use only:
Quantity:
CCPLQuote:
Customer:
Mnfr Date:
CCPL Invoice:
Serial Number:
CustomerPO & Date:
yes
1/2"
'L'
Dim
ensi
on (
mm
) b
etw
een
cent
res
150m
m M
in *
NB50
140m
m M
in
66000A, BI, C, D & E Rev 6 Website May 13
![Page 7: na VLI scale data sheet Picture gallery of typical units...weld socket 1" Data Sheet: 66.01D Operating Conditions HELP@controlcomponents.com.au Made under licence by: Ph: +61 (0)2](https://reader034.vdocuments.us/reader034/viewer/2022050413/5f89895db71ad0308166ed78/html5/thumbnails/7.jpg)
Media max 600cst
Density min 0.65 g/cm3
Pressure / Temperature Material dependent
Operating pressure max 10 bar @ 20 oC barDesign pressure max 10 bar @ 20 oC bar
Operating temperature -30oC to + 70oC OC
Design temperature -30oC to + 70oC OC
Test pressure: bar
Indicating RailPolycarbonate / Al flags: Red (std), Yellow, Blue (700C max)
Polyolefin protection: Heat shrink protection tubing
MaterialsFloat chamber PVC-U, PVC-C, PP, PVDF, ABS
Float model: PTFE, PVDF, PVC, 316SSGaskets / Seals:
Solvent / Cement: Tangit (Std) or DYTEX / IPS724
DimensionsConnection distance 'L' dimension (mm between centres) mm
Drop leg length from centreline of lower connection: mm
ConnectionsType 66000D 2 side sockets
Socket size NB 15, 20, 25, 32, 40, 50Pipe pieces - length from centre of pipe mmThreaded connections NB 15, 20, 25, 32, 40, 50 (M/F)
Flanged connections DN 25, 32, 40, 50 (ANSI or AS2129)
Optional (at extra cost)
Male / female fittings in sockets:
Top, bottom flange: ANSI (B16.5)
Drain: 1/2" BSP, M or FVent: 1/2" BSP, M or FVent /drain valves: Ball valves. EPDM / Viton seals
Isolation valves. EPDM / Viton seals
Rev AccessoriesMagnetic switches: Qty: Model:
Transmitter: Control range mm: Model:
Special RequirementsInstrument tags (20x40mm of 316SS)
Support bracket (1 standard for lengths over 2m)
Support frame 316 SS / Alum. Details below.
Measuring Scale Details below.
Safe Fill sign kit
Notes
Control Components Pty Ltd
Mnfr Date:
CCPL Invoice:
66000D InvertedSide socket connections
Technical Data
Magnetic Level Indicator
Factory use only:
Serial Number:
CCPLQuote:
Customer:
CustomerPO & Date:
Quantity:
Made under licence by:
Ph: +61 (0)2 9542 8977 Fx: +61 (0)2 9542 7978
Data Sheet: 66.01DI
Operating Conditions
'L'
Dim
ens
ion
(mm
) b
etw
een
cent
res
66000A, BI, C, D & E Rev 6 Website May 13
![Page 8: na VLI scale data sheet Picture gallery of typical units...weld socket 1" Data Sheet: 66.01D Operating Conditions HELP@controlcomponents.com.au Made under licence by: Ph: +61 (0)2](https://reader034.vdocuments.us/reader034/viewer/2022050413/5f89895db71ad0308166ed78/html5/thumbnails/8.jpg)
66000E
Media max 600cst
Density min 0.65 g/cm3
Pressure / Temperature Material dependent
Operating pressure max 10 bar @ 20 oC barDesign pressure max 10 bar @ 20 oC bar
Operating temperature -30oC to + 70oC OC
Design temperature -30oC to + 70oC OC
Test pressure: bar
Indicating RailPolycarbonate / Al flags: Red (std), Yellow, Blue (700C max)
Polyolefin protection: Heat shrink protection tubing
MaterialsFloat chamber PVC-U, PVC-C, PP, PVDF, ABS
Float model: PTFE, PVDF, PVC, 316SS
Gaskets / Seals:
Solvent / Cement: Tangit (Std) or DYTEX / IPS724
DimensionsConnection distance 'L' dimension (mm between centres) mm
Drop leg length from centreline of lower connection: mm
ConnectionsType 66000E 1 side connection & vent
Upper fitting: size:
Lower fitting: size:
Bottom float access 2" blind union end (Std) or ANSI flange
Optional (at extra cost)
Top fittingDrain: 1/2" BSP port with plug
Vent /drain valves: Ball valves. EPDM / Viton sealsIsolation valves. EPDM / Viton seals
Rev AccessoriesMagnetic switches: Qty: Model:
Transmitter: Control range mm: Model:
Special RequirementsInstrument tags (20x40mm of 316SS)
Support bracket A-26936-ADJ ( Note: 1 std > 2m)
Support frame 316 SS / Alum. Details below.
Measuring Scale Details below.
Notes
Control Components Pty Ltd
Factory use only:
Quantity:
Mnfr Date:
CCPL Invoice:
Side socket connectionsTechnical Data
Magnetic Level Indicator
with vented top
Serial Number:
CCPLQuote:
Customer:
CustomerPO & Date:
Made under licence by:
Ph: +61 (0)2 9542 8977 Fx: +61 (0)2 9542 7978
1
Data Sheet: 66.01D
Operating Conditions
'L'
Dim
ensi
on (
mm
) b
etw
een
cent
res
~130mm
* Vent & drain fittings may extend these dimensions.
150m
m M
in *
NB50
NB50 doublesocket union
53.5 mm
12.0 mm
12.0 mm
66000A, BI, C, D & E Rev 6 Website May 13
![Page 9: na VLI scale data sheet Picture gallery of typical units...weld socket 1" Data Sheet: 66.01D Operating Conditions HELP@controlcomponents.com.au Made under licence by: Ph: +61 (0)2](https://reader034.vdocuments.us/reader034/viewer/2022050413/5f89895db71ad0308166ed78/html5/thumbnails/9.jpg)
Media max 600cst
Density min 0.65 g/cm3
Pressure / Temperature Material dependent
Operating pressure max 10 bar @ 20 oC barDesign pressure max 10 bar @ 20 oC bar
Operating temperature -30oC to + 70oC OC
Design temperature -30oC to + 70oC OC
Test pressure: bar
Indicating RailPolycarbonate / Al flags: Red (std), Yellow, Blue (700C max)
Polyolefin protection: Heat shrink protection tubing
MaterialsFloat chamber PVC-U, PVC-C, PP, PVDF, ABS
Float model: PTFE, PVDF, PVC, 316SSGaskets / Seals:
Solvent / Cement: Tangit (Std) or DYTEX / IPS724
DimensionsConnection distance 'L' dimension (mm between centres) mm
Drop leg length from centreline of lower connection: mm
ConnectionsType 66000DE Inv 1 side socket and top vent
Socket size NB 15, 20, 25, 32, 40, 50Pipe pieces - length from centre of pipe mmThreaded connections NB 15, 20, 25, 32, 40, 50 (M/F)
Flanged connections DN 25, 32, 40, 50 (ANSI or AS2129)
Optional (at extra cost)
Male / female fittings in sockets:
Top, bottom flange: ANSI (B16.5)
Drain: 1/2" BSP M /F or 1/2" socketDrain valve: EPDM seal double union valveVent: Elbow, Union, threaded port
Isolation valves. EPDM / Viton seals
Rev AccessoriesMagnetic switches: Qty: Model:
Transmitter: Control range mm: Model:
Special RequirementsInstrument tags (20x40mm of 316SS)
Support bracket (1 standard for lengths over 2m)
Support frame 316 SS / Alum. Details below.
Measuring Scale Details below.
Safe Fill sign kit
Notes
Control Components Pty LtdMade under licence by:
Ph: +61 (0)2 9542 8977 Fx: +61 (0)2 9542 [email protected]
Mnfr Date:
CCPL Invoice:
CustomerPO & Date:
Serial Number:
Quantity:
Customer:
Factory use only:
CCPLQuote:
66000DE Inverted
Technical Data Operating Conditions
Magnetic Level Indicator Side socket connection & vent Data Sheet: 66.01DEI
'L'
Dim
ens
ion
(mm
)
200 - 270mmmedia SGdependant
~200mm
66000A, BI, C, D & E Rev 6 Website May 13
![Page 10: na VLI scale data sheet Picture gallery of typical units...weld socket 1" Data Sheet: 66.01D Operating Conditions HELP@controlcomponents.com.au Made under licence by: Ph: +61 (0)2](https://reader034.vdocuments.us/reader034/viewer/2022050413/5f89895db71ad0308166ed78/html5/thumbnails/10.jpg)
Level Indicator type & serial number:
Indicator connection length ('L' in mm):
Scale mounting (RHS standard):
Scale materials and colour:
Graduations:
Major bars:
Intermediate bars:
Minor bars:
Scale legend and position:
Additional comments
(add sketch in area to left or over page, if req'd)
Sketch (as necessary):
CCPL production order:
Number of units: Date required:
Notes:Control Components Pty LtdPh: +61 (0)2 9542 8977 Fx: +61 (0)2 9542 7978Email: [email protected]: www.ccezy.com.au ABN: 24 080 175 293
Drawn: PGM Date: ~ Smartline (33.7mm OD pipe) 30mm Revision: 4 Date: ~ Standardline (>53mm ) OD pipe) 50mm Not to scale
Alt legend position
mm
LHS RHS
316SS Engraved lettering, paint fill colour:
Alumimium
0
Brass
WhiteColorbond
Vinyl lettering color:
Ove
rall
leng
th:
0
Sca
le le
ngth
=
in
dica
tion
leng
th
mm
LHS Area for legend RHS
mm
~ Scale default is right hand side (RHS) mounting. LHS mounting requirement to be specified on order.
~ Scales are mounted with: SS brackets (# 36617), clamps, socket mushroom head screws, washers and Nyloc nuts.
~Scales are shipped mounted to the indicator. If not practical to do so, they are fully prepared for mounting. Visual level indicator measuring scale specification sheet
~ Indication rail and scale extend beyond indication length each end (std): 5-Jul-06
14-Apr-08
70mm
Volume
10mm 90 degreturn
%
66000A, BI, C, D & E Rev 6 Website May 13 Page 15 of 18 Rev 4 13/06/2013
![Page 11: na VLI scale data sheet Picture gallery of typical units...weld socket 1" Data Sheet: 66.01D Operating Conditions HELP@controlcomponents.com.au Made under licence by: Ph: +61 (0)2](https://reader034.vdocuments.us/reader034/viewer/2022050413/5f89895db71ad0308166ed78/html5/thumbnails/11.jpg)
Weka level indicator measuring scale specification sheet - additional information:
Level Indicator type & serial number:
Indicator connection length ('L' in mm):
Control Components Pty LtdPh: +61 (0)2 9542 8977 Fx: +61 (0)2 9542 7978Email: [email protected]: www.ccezy.com.au ABN: 24 080 175 293
Drawn: PGM Date: Revision: 4 Date: Not to scale
Enter data, sketches or XLS tables in highlighted areas only.
0 0
0
Page 2 of 2
Visual level indicator measuring scale specification sheet
5-Jul-0614-Apr-08
66000A, BI, C, D & E Rev 6 Website May 13 Page 16 of 18 Rev 4 13/06/2013
![Page 12: na VLI scale data sheet Picture gallery of typical units...weld socket 1" Data Sheet: 66.01D Operating Conditions HELP@controlcomponents.com.au Made under licence by: Ph: +61 (0)2](https://reader034.vdocuments.us/reader034/viewer/2022050413/5f89895db71ad0308166ed78/html5/thumbnails/12.jpg)
![Page 13: na VLI scale data sheet Picture gallery of typical units...weld socket 1" Data Sheet: 66.01D Operating Conditions HELP@controlcomponents.com.au Made under licence by: Ph: +61 (0)2](https://reader034.vdocuments.us/reader034/viewer/2022050413/5f89895db71ad0308166ed78/html5/thumbnails/13.jpg)
Typical 66000 arrangements
![Page 14: na VLI scale data sheet Picture gallery of typical units...weld socket 1" Data Sheet: 66.01D Operating Conditions HELP@controlcomponents.com.au Made under licence by: Ph: +61 (0)2](https://reader034.vdocuments.us/reader034/viewer/2022050413/5f89895db71ad0308166ed78/html5/thumbnails/14.jpg)
Typical units
UPVC 66000A withflanged float access
PVDF 65000A (DN40)with switches.
Special layout to customer requirements
UPVC 66000A units with isolation and drain valves
![Page 15: na VLI scale data sheet Picture gallery of typical units...weld socket 1" Data Sheet: 66.01D Operating Conditions HELP@controlcomponents.com.au Made under licence by: Ph: +61 (0)2](https://reader034.vdocuments.us/reader034/viewer/2022050413/5f89895db71ad0308166ed78/html5/thumbnails/15.jpg)
ANSI cl150 Vanstone process connection flange
Process connection flange to AS2129 via SS backing ring
Drain valve alternatives
![Page 16: na VLI scale data sheet Picture gallery of typical units...weld socket 1" Data Sheet: 66.01D Operating Conditions HELP@controlcomponents.com.au Made under licence by: Ph: +61 (0)2](https://reader034.vdocuments.us/reader034/viewer/2022050413/5f89895db71ad0308166ed78/html5/thumbnails/16.jpg)
![Page 17: na VLI scale data sheet Picture gallery of typical units...weld socket 1" Data Sheet: 66.01D Operating Conditions HELP@controlcomponents.com.au Made under licence by: Ph: +61 (0)2](https://reader034.vdocuments.us/reader034/viewer/2022050413/5f89895db71ad0308166ed78/html5/thumbnails/17.jpg)
Inverted UPVC 66000D with scale
Standard UPVC 66000A withblind union end float access
UPVC 66000A with flanged float access
UPVC and 316SS Top of Tank units
![Page 18: na VLI scale data sheet Picture gallery of typical units...weld socket 1" Data Sheet: 66.01D Operating Conditions HELP@controlcomponents.com.au Made under licence by: Ph: +61 (0)2](https://reader034.vdocuments.us/reader034/viewer/2022050413/5f89895db71ad0308166ed78/html5/thumbnails/18.jpg)
Typical WTP installation