MWS ® Catalog # Type Date Project Comments Prepared by DC-5LT DROP CABLE Modular Wiring System MWS-5LT, Modular Wiring Systems with DALI Control, provides low cost installation of both power for lighting and Class 1 control wiring for use with Fifth Light DALI systems. Using modular components that plug together, MWS-5LT can be installed in a fraction of the time of hardwiring both lighting and control. Plus, MWS-5LT offers the advantage of relocating fixtures and DALI control devices for future renovations. The MWS Drop Cable with DALI Control (DC-5LT) feeds power and con- trol to wall or ceiling fixtures from a compatible Circuit T (CT) or Splitter (SP). See the CT or SP specification sheets for compatibility details. MWS Drop cables may be plugged into the last fixture cable (FC) or from a Splitter (SP) anywhere within the system. DESCRIPTION DESIGN FEATURES • UL Listed under Standard 183 for make or break under load. • Meets requirements of Article 604 of the National Electrical Code. • MWS components assembled with 12 AWG conductors rated at 20 amperes with full size ground wire. • Copper conductors are THHN insulated wire rated 90°C. • Galvanized steel exterior with integral keying for voltage and amperage. • Valox 365 constructed contact housings are approved for environmental air plenums. • Cable end supplied with 1/2" connector with locknut and 6" pre- stripped leads. • DC cable allows you to easily supply power and control to other system units. Cable Unit Standard Length Wt. Qty./Carton 9’ 3.0 lbs. 9 15’ 4.5 lbs. 8 SHIPPING DATA S Y S T E M S C E R T I F I E D Drop Cable (DC) Supplies power and control to system units. Typical MWS Wiring System Application shown utilizing Drop Cable (DC). Consult MWS Installation, Application and Specification Manual for additional comprehensive system information. Extender Cable Splitter or Circuit T Extender Cable Drop Cable Junction Box or any Out of System Unit supplied by others. SYSTEM VIEW (not to scale) MWS AUTOCAD DRAFTING MWS offers AutoCAD drafting to layout MWS, providing the contractor with additional benefits. MWS design layout time is reduced. Bills of material are computer-generated guaranteeing accuracy. MWS drawing symbols and details standardized. Layouts are available on CD or e-mail. To utilize this service and for additional information, contact the MWS Sales Department (888) 487-4887. PS510002EN 2015-04-06 13:31:07 All electrical boxes, conduit, connections and switches by others. Install dust covers on unused open ends. Scale is exaggerated on fixtures and MWS system applications. Top Side 4-3/8" [112mm] 1-7/8" [47mm] 5/8" [16mm] DIMENSIONAL DATA SAMPLE NUMBER: 27DC12/4G095LT Component DC=DropCable DC Voltage 12=120V 27=277V Conductors and Size 12/4G=#12, 4 Conductors Plus Ground Cable Length (Feet) 09=9' 15=15' Options 5LT Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. ORDERING INFORMATION Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Specifications and dimensions subject to change without notice. Eaton’s Cooper Lighting Business 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting

Upload: others

Post on 23-Apr-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

MWS®

Catalog # Type

Date

Project

Comments

Prepared by

DC-5LT

DROP CABLEModular Wiring System

MWS-5LT, Modular Wiring Systems with DALI Control, provides low cost installation of both power for lighting and Class 1 control wiring for use with Fifth Light DALI systems. Using modular components that plug together, MWS-5LT can be installed in a fraction of the time of hardwiring both lighting and control. Plus, MWS-5LT offers the advantage of relocating fixtures and DALI control devices for future renovations.

The MWS Drop Cable with DALI Control (DC-5LT) feeds power and con-trol to wall or ceiling fixtures from a compatible Circuit T (CT) or Splitter (SP). See the CT or SP specification sheets for compatibility details.

MWS Drop cables may be plugged into the last fixture cable (FC) or from a Splitter (SP) anywhere within the system.

DESCRIPTION

DESIGN FEATURES

• UL Listed under Standard 183 for make or break under load.

• Meets requirements of Article 604 of the National Electrical Code.

• MWS components assembled with 12 AWG conductors rated at 20 amperes with full size ground wire.

• Copper conductors are THHN insulated wire rated 90°C.

• Galvanized steel exterior with integral keying for voltage and amperage.

• Valox 365 constructed contact housings are approved for environmental air plenums.

• Cable end supplied with 1/2" connector with locknut and 6" pre-stripped leads.

• DC cable allows you to easily supply power and control to other system units.

Cable Unit Standard

Length Wt. Qty./Carton

9’ 3.0 lbs. 9

15’ 4.5 lbs. 8

SHIPPING DATA

S

YSTEMS

C

E RT I F I E

D

Drop Cable (DC)Supplies power and control to system units.

Typical MWS Wiring System Application shown utilizing Drop Cable (DC).

Consult MWS Installation, Application and Specification Manual for additional comprehensive system information.

Extender Cable Splitter orCircuit T

Extender Cable

Drop Cable

Junction Box or any Out of System Unit supplied by others.

SYSTEM VIEW (not to scale)

MWS AUTOCAD DRAFTINGMWS offers AutoCAD drafting to layout MWS, providing the contractor with additional benefits.

MWS design layout time is reduced.

Bills of material are computer-generated guaranteeing accuracy.

MWS drawing symbols and detailsstandardized.

Layouts are available on CD or e-mail.

To utilize this service and for additionalinformation, contact the MWS Sales Department (888) 487-4887.

PS510002EN2015-04-06 13:31:07

All electrical boxes, conduit, connections and switches by others.

Install dust covers on unused open ends.

Scale is exaggerated on fixtures and MWS system applications.

Top

Side

4-3/8"[112mm]

1-7/8"[47mm]

5/8"[16mm]

DIMENSIONAL DATA

SAMPLE NUMBER: 2 7 D C 1 2 /4 G 0 9 5 L T

ComponentDC=DropCable

DC

Voltage12=120V27=277V

Conductors and Size12/4G=#12, 4 Conductors Plus Ground

Cable Length (Feet)09=9'15=15'

Options5LT

Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representativefor availability and ordering information.

ORDERING INFORMATION

Eaton1000 Eaton BoulevardCleveland, OH 44122United StatesEaton.com

Specifications and dimensions subject to change without notice.

Eaton’s Cooper Lighting Business 1121 Highway 74 SouthPeachtree City, GA 30269P: 770-486-4800www.eaton.com/lighting