multifunction monitoring unit with rcm residual current ......iteratioa saes departmet socomec re de...
TRANSCRIPT
-
DIRIS A80
Multifunction monitoring unit with RCM Residual Current Monitoring
COMPACT
PATENTED INNOVATION*
DEDICATED TOOLS
The leader in monitoring units, SOCOMEC’s innovative DIRIS A80 unit combines permanent monitoring of residual currents and advance energy management for electrical installations.A true benefit to the field of energy efficiency as well as asset and personal safety, the DIRIS A80 is used to control energy quality whilst avoiding inconvenient installation shutdowns.
* French patent applied for
-
www.socomec.com
Non
con
trac
tual
doc
umen
t. ©
201
3, S
ocom
ec S
A. A
ll rig
hts
rese
rved
.
hEAD OffICE
SOCOMEC GROUPS.A. SOCOMEC capital 10 951 300 €R.C.S. Strasbourg B 548 500 149B.P. 60010 - 1, rue de Westhouse F-67235 Benfeld Cedex - FRANCE
INTERNATIONAL SALES DEPARTmENT
SOCOMEC1, rue de Westhouse - B.P. 60010 F - 67235 Benfeld Cedex - FRANCETel. +33 (0)3 88 57 41 41 Fax +33 (0)3 88 74 08 [email protected]
YOUR DISTRIBUTOR
• 4e_couv_SCP_130213_fiche.indd 6 22/02/13 10:26
CO
UV
205
A -
SIT
E 46
3 A
- T
OR
E 04
6 A
- D
IRIS
876
AFI
P 2
1033
- 0
3 / 1
3 -
Pho
to: M
artin
Ber
nhar
t - R
éalis
atio
n: S
OC
OM
EC
- G
yss
Impr
imeu
r O
bern
ai -
To
help
pro
tect
the
envi
ronm
ent,
this
doc
umen
t has
bee
n pr
inte
d on
PE
FC p
aper
(Pro
gram
me
for
the
End
orse
men
t of F
ores
t Cer
tific
atio
n)
DIRIS A80Multifunction monitoring unit with RCM Residual Current Monitoring
Benefits
• CompactThe DIRIS A80’s case houses two complementary products, enabling faster installation with less space lost. The DIRIS A80 comprises:- a multifunction monitoring unit,- an RCM (Residual Current Monitoring)
monitor.
• Patentedinnovation*Automatic adjustment of the leakage current alarm threshold in accordance with the load current to avoid false alarms.* French patent applied for
• DedicatedDIRISA80tools- Webserver tool, integrated within
the optional Ethernet module, for monitoring and exploiting data remotely without the necessity of installing software.
ApplicationsThe A80 unit is indispensable in installations where a reliable, available electrical power supply is essential and quick fault current detection is required:- sensitive installations: security,
availability and reliability of supply are critical (data centre, bank, hospital etc.),
- preventive maintenance of critical circuits: monitoring of production lines, cable insulation checks, verification of earth connections etc.
DIRIS A80
Type References
With 2 outputs 4825 0213With 1 input / 1 output 4825 0214
PC
DIRIS A80 DIRIS A80
Eth
erne
t
VERTELISsoftwaresolution
PLC
Currentsper phasecurve
Mainmeter panel
DIRIS A80
DIRIS A80
RS-485
Compliance• IEC 61557-12• IEC 62020• IEC 62053-22 class 0.5 S• IEC 62053-23 class 2 Residualcoresareessentialtothe
operationoftheDIRISA80.The∆ICrangeiscomplete,practicalandinnovative(patentedaccessories).Learnmoreonourwebsite.
Residual cores
TOR
E_0
46_A
TOR
E_0
35_A
For more information on the DIRIS A80 unit, visit our website: www.socomec.com/en/dirisa80
To find out more:
FLC
D-U
RL_
027_
A_G
B
DIR
IS 8
75_B
- Analysis software: analyse data to improve the reliability of your electrical installation.
- Easy Config software: quick and simple configuration of the DIRIS A80 from a PC.
Specification,commissioning,maintenance,endoflife,trainingetc.Withourspecialists,youwillsoonberunningtheDIRISA80inyourenvironment.
Services
Options
RS485 JBus / Modbus communication module 4825 0092Ethernet communication module with integrated Webserver software 4825 0203Ethernet communication module with RS485 Modbus gateway and integrated Webserver 4825 0204
Thequalityofthepowertransformerisakeyelementforguaranteeingaccuratereadings.Socomecoffersyouafull,highperformancerangetofulfilyourinstallations’requirements.
Power transformers
DIP
890
33
Current transformers
dip_89033_A.indd 1 13/11/09 9:38:24