multi-platform subsystem test - oracle · 2010-12-29 · multi-platform subsystem test messages and...

342
StorageTek Multi-Platform Subsystem Test Messages and Codes Manual Version 2.04 112151207

Upload: others

Post on 22-May-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

����������

Multi-PlatformSubsystem Test

Messages and CodesManual

Version 2.04

112151207

112151207EC 123095

The information in this document is confidential and proprietary to Storage TechnologyCorporation and may be used only under the terms of the product license or nondisclosureagreement. The information in this document, including any associated software program, maynot be disclosed, disseminated, or distributed in any manner without the written consent ofStorage Technology Corporation.

Limitation on Warranties and Liability

This document neither extends nor creates warranties of any nature, expressed orimplied. Storage Technology Corporation cannot accept any responsibility for your use of theinformation in this document or for your use of any associated software program. StorageTechnology Corporation assumes no responsibility for any data corruption or erasure as a resultof the use of the information in this document, or the use of software programs. You should becareful to ensure that your use of the information complies with all applicable laws, rules, andregulations of the jurisdictions with respect to which the information is used.

Warning: No part or portion of this document may be reproduced in any manner or in anyform without the written permission of Storage Technology Corporation.

Restricted Rights

Use, duplication, or disclosure by the U.S. Government is subject to restrictions as set forth insubparagraph (c) (1) (ii) of the Rights in Technical Data and Computer Software clause atDFARS 252.227–7013 or subparagraphs (c) (1) and (2) of the Commercial Computer Software–– Restricted Rights at 48 CFR 52.227–19, as applicable.

TrademarksStorageTek is a registered trademark of Storage Technology Corporation.

IBM is a registered trademark of International Business Machines Corporation.

Other product names mentioned in this manual may be trademarks. They are used foridentification purposes only.

Seventh Edition – April 2000

This edition applies to version 2.04 of the Multi-Platform Subsystem Test software for MVS,VM, and PC/DOS operating systems. Information contained in this publication is subject tochange. Comments concerning the contents of this manual should be directed to:

Storage Technology CorporationManager, WWCS Strategic ToolsMS: 4361One StorageTek DriveLouisville, Colorado 80028–4361

� Copyright Storage Technology Corporation 2000. All Rights Reserved.

iii About this Book

About this Book

The Multi-Platform Subsystem Test (MPST) Messages andCodes manual describes the messages issued by MPST, theStand-Alone Executive (SAE), the Control Card Editor, andMPST functions.

For messages issued by the StorageTekFRIEND function refer tothe StorageTekFRIEND Function for MPST Reference Manual.

AudienceThis book was written for Storage Technology Corporation(StorageTek) personnel to support the testing and diagnostics ofStorageTek products.

We’d like to know what you think about this book. For thatpurpose, we’ve included a reader’s comment form in the back ofthis book. Please copy the form, fill it out, and mail it to us.

Reader’sComments

iv MPST Messages and Codes Manual – Version 2.04

About the Software

The following MPST software levels are supported by this book:

� MPST/MVS Version 2.04

� MPST/VM Version 2.04

� MPST/PC Version 2.04

How this Book is Organized

This book contains the messages issued by the Multi-PlatformSubsystem Test (MPST) software program for MVS, VM, andPC/DOS operating systems. Messages are arranged in this bookalpha-numerically by message number.

� Chapter 1. “Return and Abend Codes”.

� Chapter 2. “MPSTCCE.” Control Card Editor messages.

� Chapter 3. “MPSTCCW.” Channel Command-Word Tracemessages.

� Chapter 4. “MPSTCKM.” Count-Key-Data Map messages.

� Chapter 5. “MPSTCPY.” Tape Copy messages.

� Chapter 6. “MPSTDEF.” DEFINE messages.

� Chapter 7. “MPSTGSA.” Generate Stand-Alone Programsmessages.

� Chapter 8. “MPSTINT.” Attention Interrupt messages.

� Chapter 9. “MPSTLEX.” LSM Exerciser messages.

� Chapter 10. “MPSTLIB.” Library Mount messages.

� Chapter 11. “MPSTLOK.” Library Look messages.

� Chapter 12. “MPSTMAN.” MPST Main Processingmessages.

v About this Book

� Chapter 13. “MPSTRLB.” Random Locate Blockmessages.

� Chapter 14. “MPSTTIP.” Tape Independent Protocol Setmessages.

� Chapter 15. “MPSTTKD.” Track Dump messages.

� Chapter 16. “MPSTTMC.” Tape Monitor and Controlmessages.

� Chapter 17. “MPSTTSC.” Tape Scan messages.

� Chapter 18. “MPSTVSC.” Volume Scan messages.

� Chapter 19. “MPSTVTM.” Terminal Control UnitVerification messages

� Chapter 20. “MPSTWRC.” Write-Read Cartridgemessages.

� Chapter 21. “MPSTWRD.” Write-Read Disk messages.

� Chapter 22. “MSAE.” MPST Stand-Alone Executivemessages.

� Index

vi MPST Messages and Codes Manual – Version 2.04

Conventions for Reader Usability

Conventions are used to shorten and clarify explanations andexamples within this book.

The following typographical conventions are used in this book:

� Bold is used to introduce new or unfamiliar terminology.

� �����������is used to indicate command names,filenames, and literal output by the computer.

� ���������������� is used to indicate literal input tothe computer.

� ����� ��������������is used to indicate that you mustsubstitute the actual value for a command parameter. Inthe following example, you would substitute your name forthe “username” parameter.

���� ���� ���

� A bar ( | ) is used to separate alternative parameter values.In the example shown below either username orsystemname must be entered.

���� ���� ��������������

� Brackets [ ] are used to indicate that a command parameteris optional.

� Ellipses ( ... ) are used to indicate that a command may berepeated multiple times.

� The use of mixed upper and lower case characters (fornon-case sensitive commands) indicates that lower caseletters may be omitted to form abbreviations. Forexample, you may simply enter ���when executing the������command.

Typographic

vii About this Book

Single keystrokes are represented by double brackets ���

surrounding the key name. For example, press �ESC� indicatesthat you should press only the escape key.

Combined keystrokes use double brackets and the plus sign (+).The double brackets surround the key names and the plus sign isused to add the second keystroke. For example, press �ALT��+

�C� indicates that you should press the alternate key and the Ckey simultaneously.

The instruction to “press the �ENTER� key” is omitted from mostexamples, definitions, and explanations in this book.

For example, if the instructions asked you to “enter”���������, you would type in�����������and press�ENTER�.

However, if the instructions asked you to “type”������

���, you would type in�����������and you would notpress �ENTER�.

The following symbols are used to highlight text in this book.

Warning: Information necessary to keep you from damagingyour hardware or software.

Caution: Information necessary to keep you from corruptingyour data.

Hint: Information that can be used to shorten or simplify yourtask or they may simply be used as a reminder.

Note: Information that may be of special interest to you. Notesare also used to point out exceptions to rules or procedures.

Keys

Enter Command

Symbols

STOP

!

xxxxxxxx

viii MPST Messages and Codes Manual – Version 2.04

Technical Support

Contact CS Software Support at 1–800–866–6789.

Related Documentation

The following books provide more information about the MPSTsoftware product:

� MPST/PC Installation and User’s Guide

� MPST/PC Functions Reference Manual

� MPST/MVS Installation and User’s Guide

� MPST/MVS Functions Reference Manual

� MPST/VM Installation and User’s Guide

� MPST/VM Functions Reference Manual

� StorageTekFRIEND Function for MPST Reference Manual

ix Contents

Contents

About this Book iii. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Audience iii. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Reader’s Comments iii. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . About the Software iv. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . How this Book is Organized iv. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Conventions for Reader Usability vi. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Typographic vi. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Keys vii. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Enter Command vii. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Symbols vii. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Technical Support viii. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Related Documentation viii. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Chapter 1. Return and Abend Codes 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Program and Function Return Codes 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Abnormal End (ABEND) Codes 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Chapter 2. MPSTCCE 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Control Card Editor Messages 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Chapter 3. MPSTCCW 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Channel Command-Word Trace (CCWTRACE) Messages 15. . . . . . . . . . . . . . . . . . . . . . . . . .

Chapter 4. MPSTCKM 19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Count-Key-Data Map (CKDMAP) Messages 19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Chapter 5. MPSTCPY 25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tape Copy Messages 25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

x MPST Messages and Codes Manual – Version 2.04

Chapter 6. MPSTDEF 47. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DEFINE Messages 47. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Chapter 7. MPSTGSA 53. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Generate Stand-alone Programs (GENSAPGM) Messages 53. . . . . . . . . . . . . . . . . . . . . . . . . . .

Chapter 8. MPSTINT 61. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Attention Interrupt Messages 61. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Chapter 9. MPSTLEX 63. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Library Storage Module Exerciser (LSMEXER) Messages 63. . . . . . . . . . . . . . . . . . . . . . . . . .

Chapter 10. MPSTLIB 91. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Library Mount (LIBMOUNT) Messages 91. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Chapter 11. MPSTLOK 109. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Library Look (LIBLOOK) Messages 109. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Chapter 12. MPSTMAN 117. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MPST Main Processing (MPSTMAIN) Messages 117. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Chapter 13. MPSTRLB 129. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Random Locate Block (RLB) Messages 129. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Chapter 14. MPSTTIP 151. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tape Independent Protocol Set (TIPS) Messages 151. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Chapter 15. MPSTTKD 157. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Track Dump (TRKDUMP) Messages 157. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Chapter 16. MPSTTMC 171. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tape Monitor and Control (TMC) Messages 171. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Chapter 17. MPSTTSC 177. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tape Scan Messages 177. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Chapter 18. MPSTVSC 201. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Volume Scan (VOLSCAN) Messages 201. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Chapter 19. MPSTVTM 219. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Terminal Control Unit Verification (VTERM) Messages 219. . . . . . . . . . . . . . . . . . . . . . . . . . . .

xi Contents

Chapter 20. MPSTWRC 223. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Write-Read Cartridge (WRCART) Messages 223. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Chapter 21. MPSTWRD 251. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Write-Read Disk (WRDISK) Messages 251. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Chapter 22. MSAE 263. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MPST Stand-Alone Executive (MPSTSAE) Messages 263. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Index 327. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

xii MPST Messages and Codes Manual – Version 2.04

1 Chapter 1. Return and Abend Codes

Chapter 1. Return and Abend Codes

Program and Function Return Codes

The return code sent to the system is the highest return codeposted by any function to MPST. A return code is only sent ifMPST executes successfully.

Refer to the appropriate Multi-Platform Subsystem TestFunctions Reference Manual for additional information on�����and function return code testing.

ReturnCode

Program Use Function Use

0 No errors No errors

4 Not used Warning or minor error

8 Not used Serious error

12 Control card error Control card error or testdevice ���� failure

16 File ������ or ����failed to ����

2 MPST Messages and Codes Manual – Version 2.04

Abnormal End (ABEND) Codes

������codes indicate problems within the MPST program. Thefollowing ����� codes apply to MPST:

ABEND Code 087An [E]STAE environment could not be established for anOS/VS environment. Contact CS Software Support.

ABEND Code 088�������for MPST��������������������������������failed. Increase the partition or region size and tryagain.

ABEND Code 089�������for MPST�����������������������������failed. Increase the partition or region size and try again.

ABEND Code 090Not used. Contact CS Software Support.

ABEND Code 091������/��������problem. Contact CS SoftwareSupport.

ABEND Code 092Test device�� ��/�����problem. Contact CS SoftwareSupport.

ABEND Code 093Write to operator problem. Contact CS Software Support.

ABEND Code 094MPST program modules are not at the correct level.Remove all older versions of MPST from the system.

3 Chapter 1. Return and Abend Codes

ABEND Code 095The field test version of MPST has expired. Once a fieldtest has expired MPST prompts the operator for apassword. If the password is entered, execution continues;if the password is not entered, MPST abends. Install thelatest version of MPST.

ABEND Code 099Option�������is in effect and the specified trace point IDhas been reached.

4 MPST Messages and Codes Manual – Version 2.04

5 Chapter 2. MPSTCCE

Chapter 2. MPSTCCE

Control Card Editor Messages

All MPST functions and diagnostics use standard I/O operationchecking routines and these routines issue standard messages forerrors. Error message numbers are issued according to whichfunction or diagnostic was being run when the error occurred.

Hint: To make finding the messages easier, both the messagenumber and the message text are bold.

The following messages are issued for the Control Card Editor:

MPSTCCE00 MPSTCCE05

6 MPST Messages and Codes Manual – Version 2.04

�������� ������������ ���������

Explanation: This message is issued at the start of the ControlCard Editor.

Solution: None required.

�������� ��������� ������������������� ��������

Explanation: Either the���������or���������file does notexist or there are no Control Cards in the existing file.

Solution: Check the���������or���������file for ControlCards.

�������� ��� �������� ���������������������

Explanation: The requested default Control Card set ��� wasnot found in the���������file.

Solution: Check the���������file for control cards set����.

�������� ���� ����������������������������� �����

Explanation: The MPST function listed is invalid.

Solution: Correct the function name listed in the SYSINControl Card or in the Control Card.

�������� ����������

Explanation: No SYSIN data was detected in the Job JCL.

Solution: Correct the Job JCL or use the Control Card Editor.

MPSTCCE06 MPSTCCE22

7 Chapter 2. MPSTCCE

��������� ����������������������� �������������

Explanation: The current Active and Alternate Control Cardsfailed to save to the��������� ile.

Solution: Check that the���������still exists and that datacan be written to the file.

��������� ������������������������������������ ���������!"���

Explanation: The Control Card Editor requires a response.

Solution: Enter one of the following:

� ����—to list the Control Card Editor’s edit commands.

� ����—to list the control card sets defined in the�������file. �������� lists the control cards incontrol card set ����.

� ���$ #—to list the control card set numbers defined inthe����������file. ���$ #�� lists the control cards forcontrol card set���.

� �� —to terminate.

��������� ������������������� �

Explanation: There is no active Control Card in the��������

file.

Solution: Check the���������file for active Control Cards.

��������� ���������������� ��������������������������

�������������������

Explanation: The current active control cards are all listed.

Solution: None required.

MPSTCCE23 MPSTCCE29

8 MPST Messages and Codes Manual – Version 2.04

���� ��� ������ ������� ����������!'�#%��%#"$'�#%�� &�#%��#

Explanation: The Control Card Editor requires a response.

Solution: Respond to message ��������:

� Enter���!'�if you want to list, swap, or modify alternateand/or active control card sets.

� Enter��%#"$'�if you want to list the available control cardset (����) or request a specific control card set�������.

� Enter�� &�if you want to build the control card set online.

� Enter��#�if you do not need to modify control cardstatements and you’re ready to start MPST operation usingthe current, active control card set.

���� ��� ������ ������� �������������#%������

Explanation: The Control Card Editor requires a response.Message����������will sequentially display Control Cardnumbers 01 through 16 until����is entered.

Solution: Enter the text for the Control Cards. Enter���� toterminate.

���� ��� ������� ��������� �����

Explanation: The text entered for Control Card ��� wasaccepted. Message����������follows this message anddisplays the next sequential Control Card number.

Solution: None required.

���� �� ������������������ ������� ������������

Explanation: The maximum number of Control Cards that canbe entered for a set is 16.

Solution: None required.

MPSTCCE32 MPSTCCE52

9 Chapter 2. MPSTCCE

������ �� �� ������������������������� ����� �����������������������������

Explanation: Controls Cards 1 through ��� are listed for thecurrent active Control Card set.

Solution: None required.

������ �� �� �������������� � ���� ����� ��������������������

Explanation: The parameters available for Control Card ����

function are listed.

Solution: None required.

������ �� �� ������������ ������������������ ���� ���� ����� ������ �������������� ������ ����

Explanation: ������ was entered and the available defaultControl Card sets are listed.

Solution: None required.

������ �� ������������ ����������

Explanation: The HELP file�������was not found.

Solution: Load the�������file. Refer to the installationinstructions.

������ �� �� �� ��������������� ������ ��

Explanation: The Control Card Editor requires a response.

Solution: Enter the edit command to be performed, ���� to listthe available edit commands, or ��� to terminate the editfunction.

MPSTCCE53 MPSTCCE55

10 MPST Messages and Codes Manual – Version 2.04

�������� ��!����������������������������

Explanation: The edit command �������� is not valid.

Solution: Enter the correct edit command or ���� to list theavailable edit commands.

�������� !����������������������������� � ��������������������!��������������� � ���������#�����&%�����"����� � ��"���������������� � ��������������� ����� � � ������������������ � ������������� � ���� ������������������������ � �����!���������������������� � ���������������� � ����������������� � ���������!����������� � ����������������������� � �������������������������� � ��������� ������������!� � ��!������!���������������������"�� � �"�������!������������������ � �����������������!������� ����� � ���������

������������$��������������� �� ��

Explanation: The valid edit commands are listed.

Solution: None required.

������� ����������������

Explanation: Edit was requested, but there are no currentControl Cards.

Solution: Enter the name or number for the current ControlCard set.

MPSTCCE56 MPSTCCE61

11 Chapter 2. MPSTCCE

������ �� ����� ��������� � ��

Explanation: The current Control Card �� is listed with itscontents.

Solution: None required.

������ �� �����������������������

Explanation: Either ���� (list active) or ���� (list alternate)was entered and there are no Control Cards for that request.

Solution: Enter the correct request.

������ �� �� ��� ��� � ��������������

Explanation: The edit command����(replace) was entered.The Control Card Editor requires a response.

Solution: Enter the contents for the replacement Control Card.

������ � ���� ����� ������

Explanation: Control Cards are being inserted into the ControlCard Set and there is no more room. The maximum number ofcontrol cards allowed per control card set is 16.

Solution: End insert mode.

������ �� � ������� �� ����������

Explanation: A change from/to command was entered and thechange from text was not found in the current Control Card.

Solution: Enter the correct change command.

������ �� ��� ������ ���� �� ��������� ��

Explanation: Either ��� (insert after) or ��� (insert before)was entered. The Control Card Editor requires a response.

Solution: Enter the contents of the Control Card being inserted.

MPSTCCE62 MPSTCCE93

12 MPST Messages and Codes Manual – Version 2.04

�������� ���������������� �����

Explanation: The list of active Control Cards was requestedand are listed as part of this message.

Solution: None required.

�������� ����� ������������ �����

Explanation: The list of alternate Control Cards was requestedand are listed as part of this message.

Solution: None required.

�������� ������������ ��������������������

Explanation: Default Control Card set ��� was requested andwas not found in the���������file.

Solution: Enter the correct request.

�������� ������������ �����

Explanation: The Active Control Cards are listed.

Solution: None required.

�������� � ������������ �����

Explanation: The Alternate Control Cards are listed.

Solution: None required.

�������� ��������������� �����

Explanation: No Active Control Cards were found in the��������file.

Solution: None required.

MPSTCCE94 MPSTCCE99

13 Chapter 2. MPSTCCE

�������� ������ ������� ����� ��

Explanation: No Alternate Control Cards were found in the���������file.

Solution: None required.

�������� ������ ����� �������

Explanation: The Control Card Editor has terminated.

Solution: None required.

14 MPST Messages and Codes Manual – Version 2.04

15 Chapter 3. MPSTCCW

Chapter 3. MPSTCCW

Channel Command-Word Trace (CCWTRACE) Messages

All MPST functions and diagnostics use standard I/O operationchecking routines and these routines issue standard messages forerrors. Error message numbers are issued according to whichfunction or diagnostic was being run when the error occurred.

Hint: To make finding the messages easier, both the messagenumber and the message text are bold.

The following messages are issued for Channel Command-WordTrace:

MPSTCCW40 MPSTCCW40

16 MPST Messages and Codes Manual – Version 2.04

� ������� ��������������� ��������������������������������� ������������ ������������������������� ��������������� ��������������� ������

Explanation: This message is issued if CCWtrace is on at thestart of I/O operation (SIO).

� ���—if this is an immediate CCW,��is displayed atthe start of the message. Otherwise,����is displayed.

� ����������� —the cpu id and the UUT of thecontrol-unit unit.

� ��� ��������—the channel-address word specifies theaddress of the channel-command word (CCW).

� �� ���—the condition code.

� ��� ������ ������������ �—the channel-status wordspecifies the key, the next CCW in the chain, the unitstatus (��) and channel status (��), and the byte count.

� ������ �������� � ����� ��������������� �—������specifies the CCW address for the channel-command word,the command code (��), data address, flag (��), �� (notused), and the byte count.

� ���������� �� ������—specifies the data address ofthe last CCW in the chain.

Solution: None required.

MPSTCCW41 MPSTCCW41

17 Chapter 3. MPSTCCW

������ ������������ ������������������ ������������������������������������������������������������

Explanation: This message is issued if CCWtrace is on and aninterrupt has occurred.

� �������� �—the cpu id and the UUT of thecontrol-unit unit.

� �� ������������ ��������—the channel-status wordspecifies the key, the next CCW in the chain, the unitstatus ( �) and channel status (��), and the byte count.

� ��� ������� � ���������������������� — �� specifies the CCW address for the channel-commandword, the command code (��), data address, flag (��), ��(not used), and the byte count.

� ������ ��������—specifies the data address ofthe last CCW in the chain.

Solution: None required.

18 MPST Messages and Codes Manual – Version 2.04

19 Chapter 4. MPSTCKM

Chapter 4. MPSTCKM

Count-Key-Data Map (CKDMAP) Messages

All MPST functions and diagnostics use standard I/O operationchecking routines and these routines issue standard messages forerrors. Error message numbers are issued according to whichfunction or diagnostic was being run when the error occurred.

Hint: To make finding the messages easier, both the messagenumber and the message text are bold.

The following messages are issued for Count-Key-Data Mag:

MPSTCKM01 MPSTCKM11

20 MPST Messages and Codes Manual – Version 2.04

�������� ����������������������

Explanation: The parameter (����) is either coded incorrectlyor is invalid for the��������function.

Solution: None required.

�������� ��������������� ����������������

Explanation: The record read from cylinder 0, head 0, record 3of the test device was not a valid volume label.

Solution: None required.

�������� �����������������������������

Explanation: The volume is not in OS Count-Key-Data format.

Solution: None required.

�������� ���������������������

Explanation: The test device is not a direct access device.

Solution: None required.

�������� �����������������

Explanation: The test device is not a supported device.Supported devices include:

� 2305–2

� 3330–1, 3330–11

� 3350

� 3380, 3380E, 3380J, 3380–3X

� 3390–1, 3390–2, 3390–3

Solution: None required.

MPSTCKM13 MPSTCKM23

21 Chapter 4. MPSTCKM

����� ��� ����������������������

Explanation: The test device failed to open.

Solution: None required.

����� ��� �������������������

Explanation: The first DSCB read in the VTOC (volume tableof contents) was not a type 4 DSCB. The VTOC is in error.

Solution: None required.

����� ��� ����������������������������� �����

Explanation: The area GETMAIN’d to hold the internal tracklist was not large enough to contain the number of extentsencountered. This should not happen.

Solution: Contact CSE Software Support.

����� ��� ��������������������������������

Explanation: The area GETMAIN’d for the internal data setlist was not large enough to contain the number of data setsencountered. This should not happen.

Solution: Contact CSE Software Support.

����� ��� �����������������������������������������

Explanation: An error was found in one or more extents duringVTOC processing. The totals for allocated and free tracks maybe incorrect due to the error.

Solution: None required.

MPSTCKM24 MPSTCKM27

22 MPST Messages and Codes Manual – Version 2.04

�������� ��������������������������

Explanation: The FMT1 DSCB contains a pointer to acorresponding FMT2 or FMT3 DSCB. The record pointed to bythis pointer was not a valid FMT2 or FMT3. The VTOC is inerror.

Solution: None required.

�������� ��������������������

Explanation: The FMT4 DSCB contains a pointer to the firstFMT6 DSCB which then points to the next FMT6 DSCB and soon. The VTOC is in error.

Solution: None required.

�������� �����������������������

Explanation: The��������function will only process up to512 split cylinder allocations. More than 512 were encountered.

Solution: Decrease the number of split cylinder allocations.

�������� ���������������������� ��������������

Explanation: Two linked lists are created during VTOCprocessing. The first is a list of data set names with informationconcerning that data set. The second is a list of all extentallocations on the pack. The error occurred when GETMAINswere attempted for these lists and not enough storage wasavailable.

Solution: Increase the region size and retry.

MPSTCKM28 MPSTCKM32

23 Chapter 4. MPSTCKM

�������� ���� ��������������������� ��������

Explanation: If a format 6 DSCB (split cylinder allocation) isencountered, a 2K table is GETMAIN’d to construct a list of allsplit cylinder allocations. The error occurred when GETMAINwas issued and not enough storage was available.

Solution: Increase the region size and retry.....

�������� ���������

Explanation: An I/O error was encountered while attempting toread the volume label at cylinder 0, head 0, record 3.

Solution: None required.

�������� ���������

Explanation: An I/O error was encountered while attempting toread a miscellaneous DSCB.

Solution: None required.

�������� ���������

Explanation: An I/O error was encountered while attempting toread the first DSCB (format 4) of the VTOC.

Solution: None required.

24 MPST Messages and Codes Manual – Version 2.04

25 Chapter 5. MPSTCPY

Chapter 5. MPSTCPY

Tape Copy Messages

All MPST functions and diagnostics use standard I/O operationchecking routines and these routines issue standard messages forerrors. Error message numbers are issued according to whichfunction or diagnostic was being run when the error occurred.

Hint: To make finding the messages easier, both the messagenumber and the message text are bold.

The following messages are issued for Tape Copy:

MPSTCPY00 MPSTCPY02

26 MPST Messages and Codes Manual – Version 2.04

��������� �� ������������

Explanation: The���������function will be executed on thedevices listed by message��������.

Solution: None required.

��������� ��� � �� �����������

Explanation: The parameter (����) is either coded incorrectlyor is invalid for the���������function.

Solution: Enter the correct parameter.

��������� �������������� ��������������� �������������� �������

Explanation: Device������at address������with volumeserial number����configured without error.

Solution: None required.

MPSTCPY03 MPSTCPY03

27 Chapter 5. MPSTCPY

�������� �������������������������������������������������������������������������������������������� ��������������������������������������������������������������������� ������������

�����������������������������������������������

�������������������������������������������������������������������������������������������������� �����������

������������������������

��������������������������������������������������������������������������������������� �������������������������������������������

�������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������

MPSTCPY04 MPSTCPY04

28 MPST Messages and Codes Manual – Version 2.04

��������������������������������������������������������������������������������������������������

Explanation: The summary for this execution of�������

for device������at address������with volume serial number�����is printed.

� The number of passes executed and the number of recordsand tape marks processed is listed along with the totalnumber of compare, sequence, temporary, and permanentread and write errors.

� The total elapsed time is the time used for all passes.

� The total bytes transferred, written, and read are also listed.

� If the������ �parameter was specified, the number ofcontrol units detected (�����) functions for read andwrite temporary, erase gap, and read and write transienterrors are listed.

� If�������� �is specified, these counts are zero (0).

� If�����is active, the counts for�����functions arelisted; otherwise they are zero (0).

Solution: None required.

��������� ����� ������ ����

Explanation: No test devices were configured for thisexecution of������� .

Solution: Verify defined devices.

MPSTCPY05 MPSTCPY07

29 Chapter 5. MPSTCPY

�������� ����������������������������������������������������������

Explanation: A���������for a portion of memory to be usedfor data comparison failed. Data comparison cannot be done.

Solution: For data comparison, increase the size of the regionor partition where MPST is executing and then re-execute.

�������� �������������

Explanation: An I/O error occurred during configuration.

This may occur when attempting to overwrite a tape using anon-expanded format device if the tape was previously writtenusing an expanded format device.

Solution: Initialize the tape with a tape mark using anon-expanded format device to correct the problem.

Warning: Initializing the tape with a tape mark will result in allexisting data on the tape being lost.STOP

MPSTCPY08 MPSTCPY11

30 MPST Messages and Codes Manual – Version 2.04

�������� ���� ������������������������������

Explanation: Device�������was not configured. ������for not configuring:

� ��������������—The test device DD card is not atype 5 DD card.

� ������������������������ —The drive isassigned to another path.

� ����������—A test sequence with a write pass wasspecified but the cartridge is file protected. No testing canbe done on this device.

� ��������—An I/O error occurred during configuration.The error was described in message����������.

� ������������������—No device has beendefined for this DD name.

� �������������������������—�������is activeand only ����� or ����� are allowed.

� ��������—An open for the device failed.

� ����������������� —Device characteristics readdo not match the DD type specified.

� ��������—Unable to get sense data from the device.

� �������������������—The test device DD carddoes not define a cartridge device.

Solution: Verify that the test devices are correctly defined,online and available.

�������� �������������������������������� �����

Explanation: The number of passes specified by the������

parameter has been completed for device�������at address�����with volume serial number�����. Testing hasterminated on that device but continues on other devices.

Solution: None required.

MPSTCPY12 MPSTCPY20

31 Chapter 5. MPSTCPY

�������� ��������������������������������������������

Explanation: ��������has detected that a������commandwas entered at the operator’s console. Testing on test device����at address�����with volume serial number������hasbeen stopped.

Solution: None required.

�������� ����������������������������������������������

Explanation: Testing on test device�����at address����with volume serial number������has been terminated due toa permanent error.

Solution: None required.

�������� ���������������������������������� ���������������

Explanation: ����commands issued to configure the devicewere rejected.

Solution: Verify that the device has the current level ofmicrocode.

�������� ������������������� ��

Explanation: The tape comparison passed (OK) or failed andthe data � �� is one of the following:

� �������Byte Record number�

� Tape Mark number�

� 2nd Tape Mark number�

Solution: None required.

MPSTCPY21 MPSTCPY23

32 MPST Messages and Codes Manual – Version 2.04

��������� �������������������������

Explanation: �����is active and the data ���� is:

� �������Byte Record number�������

� Tape Mark number�������

� 2nd Tape Mark number�������

Solution: None required.

��������� �� ������������������������

Explanation: ������is active and the data ���� is:

� �������Byte Record number�������

� Tape Mark number�������

� 2nd Tape Mark number�������

Solution: None required.

��������� �� �������������������������� ��� ���������� �

Explanation: �����, �����, or ������ are active and thedata has been detected.

Solution: Respond to the message:

� Respond� ��to not copy data to output.

� Respond�����to copy data to output.

� Respond����to copy data to output and to end theconfirmation operation.

MPSTCPY24 MPSTCPY26

33 Chapter 5. MPSTCPY

�������� ���������������

Explanation: ���was entered for the confirm response and���� is being skipped. ���� is one of the following:

� 2nd Tape Mark

� Tape Mark

� Record

Solution: None required.

�������� �������������������������� ����������������������

Explanation: Skipping is active and copy has not yet started.

Solution: Respond to the message:

� Respond����to not start copy.

� Respond�����to start copy.

�������� �������������������������� �

Explanation: An error with ERPA code �� detected.

Solution: Respond to the message:

� Respond����to not skip the error. ���������ends with anerror.

� Respond�����to skip the error and continue.

� Respond� ���to skip the error and try to Forward SpaceBlock. Depending on the error, this response may or maynot work.

MPSTCPY27 MPSTCPY30

34 MPST Messages and Codes Manual – Version 2.04

��������� �������������

Explanation: ���or�����was entered for the skip ERPAmessage. ���� is one of the following:

� Error.

� Err & Fwr Space Block

Solution: None required.

��������� ��������������������������������������������������

Explanation: �������is active and the input cartridge tapehas a standard label.

Solution: Respond to the message:

� Respond��!�to not copy the label.

� Respond�� "�to copy the label.

��������� ��������������� ��������������������� �����

Explanation: The��������parameter was entered and allcopy functions have been disabled. Only compare operationswill run.

Solution: None required.

��������� ������������������� �������� ������

Explanation: The physical end of tape was detected on�����.

Solution: If������is the output tape, use a longer tape foroutput or enable ICRC on the output tape. Rerun ������ .

If������is the input tape, no action is required.

MPSTCPY31 MPSTCPY40

35 Chapter 5. MPSTCPY

��������� �����������������������������������������������������

Explanation: Incorrect status was received for an I/O operationto device�������at address������during a�����pass. Theactual status received was���and the command executed was���.

Solution: None required.

��������� ����������������������� �����������������������

Explanation: An open for test device�������at address�����failed after the cartridge volumes were exchanged. Testing onthe device terminates.

Solution: None required.

�������� ���������������

Explanation: The actual data read from a record did not matchthe expected data for that record.

Solution: None required.

��������� ������������������� ������������������ � ������������������������

Explanation: A read forward pass has started for device������

at address�����. The cartridge was written in ICRC format andthe drive is not capable of ICRC.

Solution: Move the cartridge to a device that is ICRC capable.

MPSTCPY41 MPSTCPY42

36 MPST Messages and Codes Manual – Version 2.04

�������� �����������������������������������������

�����������������������������������������������

����������������������������������� �����������

������������������������������������� ��������������������������

���������������������������������������������������������������������������������������������������������

Explanation: A write pass has been completed for device������at address������with volume serial number�����.The summary report for the write pass is contained within thismessage.

If������is active, the counts for������functions are listed;otherwise, they are zero.

Solution: None required.

�������� ���������������������������������������������������������

Explanation: The summary information for all passes for testdevice�������and tape volume serial number������is notbeing kept.

Solution: None required.

MPSTCPY43 MPSTCPY43

37 Chapter 5. MPSTCPY

�������� ����������������������������������������������

�����������������������������������

���������������������������������������������������������������� �����������

�������������������������������������������

������������������������������������������������������������������������������

Explanation: A read forward pass has been completed fordevice�������at address������with volume serial number����. The summary report for the read forward pass iscontained within this message.

If������is active, the counts for������functions are listed;otherwise, they are all zero.

Solution: None required.

MPSTCPY44 MPSTCPY45

38 MPST Messages and Codes Manual – Version 2.04

��������� ������������������������������������� ���������

��������������������������� ������

�������������������������������������������������������������������

�������������� ������������� ������������������������

Explanation: A read backward pass has been completed fordevice�������at address������with volume serial number����. The summary report for the read backward pass iscontained within this message.

Solution: None required.

��������� ������������������������������������������������������������������

Explanation: A read backward pass has started for device������at address�����. The cartridge was written in ICRCformat and the drive is not capable of ICRC.

Solution: Move the cartridge to a device that is ICRC capable.

MPSTCPY50 MPSTCPY50

39 Chapter 5. MPSTCPY

��������� �������� ����� �������� ���� �������������� � ���������� ����� ����������������������������������������������������������� ��������

Explanation: A temporary error was detected and the controlunit is in forced logging mode on test device������at address��� �with volume serial number����� �mounted.

� ����� ��—The record number of the record on whichthe error occurred.

� ���������—The number of bytes transferred at thetime of the error.

� ���������—The number of times the operation hasbeen retried.

� ������—The channel command being executed.

� ���������—The SIO condition code.

� �������������—The unit and channel status for CSW.

� ������—The CPU ID of the CPU on which the erroroccurred.

� ���������—The actual channel path on which the erroroccurred.

� � �������—The sense bytes.

Solution: None required.

MPSTCPY51 MPSTCPY51

40 MPST Messages and Codes Manual – Version 2.04

��������� ������������ ����������� �������� �������������������������

��������������������������������������������� ����� ��������������������������������������������

Explanation: A temporary error has occurred on test device������at address������with volume serial number�� ����at��������������������

� �������—The record number of the record on whichthe error occurred.

� ���������—The number of bytes transferred at thetime of the error.

� � �� �����—The number of times the operation hasbeen retried.

� ������—The channel command being executed.

� �������� ��—The SIO condition code.

� �������������—The unit and channel status for CSW.

� �����—The CPU ID of the CPU on which the erroroccurred.

� ���������—The actual channel path on which the erroroccurred.

� ����������—The sense bytes.

Solution: None required.

MPSTCPY52 MPSTCPY52

41 Chapter 5. MPSTCPY

��������� ���� ������������������������ ������ ����� ��������

�������������������� ������������ ������ ���� ������������������������������������������������������� �����

Explanation: A permanent error has occurred on test device���� �at address������with volume serial number�������.� ��� �������� indicates the date and time the erroroccurred. �����indicates an error condition of either ��������or���������.

� ���������—The record number of the record on whichthe error occurred.

� ��������� —The number of bytes transferred at thetime of the error.

� ���������� —The number of times the operation hasbeen retried.

� ���� �—The channel command being executed.

� �����������—The SIO condition code.

� �������������—The unit and channel status for CSW.

� � ����—The CPU ID of the CPU on which the erroroccurred.

� �������—The actual channel path on which the erroroccurred.

� �����������—The sense bytes.

MPSTCPY54 MPSTCPY54

42 MPST Messages and Codes Manual – Version 2.04

� �������������is a message describing the error. Somepossible messages and their meanings are:

� �������������������—The channel status byte ofthe CSW indicated a channel-type error.

� ������—The event control block (ECB) completioncode was not 7F (no error) or 41 (permanent error).Any other ECB code is a fatal error.

� �������������������—The error was not a datacheck or an overrun. Data checks and overruns areretried. All other errors are considered permanent.

� ��� ����������������—Read error recovery failedto recover from a temporary read error. The error isnow a permanent error.

� ��� ����������������—Write error recoveryfailed to recover from a temporary write error. Theerror is now a permanent error.

� ��������������� �������—The error occurredduring read error recovery. ��� is the commandwhich failed during retry.

� �����������������—The failing CCW could notbe determined and no recovery action could be taken.

� ��������������� �������—The error occurredduring write error recovery. ��� is the commandwhich failed during retry.

Solution: None required.

�������� ���������������������������������� ��������� ��������������������� ��

Explanation: The�������������command issued to device�����at address������with volume serial number������failed.

Solution: None required.

MPSTCPY55 MPSTCPY58

43 Chapter 5. MPSTCPY

�������� ���������������������������������������������������������������

Explanation: An error occurred on device�������at address����with volume serial number�����. The ERPA code of���is unsupported.

Solution: Notify CS Software Support of this message and givethem the sense data.

�������� ���������������������������� ��������������������

Explanation: The buffered log overflowed for device�������ataddress�����with volume serial number�����. The logcounters have been added to the statistics.

Solution: None required.

�������� ������������������������� ����������������������������������

Explanation: The buffered log data is read at the end of eachpass for device�������at address�����with volume serialnumber�����. The log counters have been added to thestatistics.

Solution: None required.

�������� ������������������������������������� ��������������� ������������

Explanation: A read buffered log CCW was issued to obtainthe current buffered log for device�������at address�����withvolume serial number�����. The CCW failed with an SIOcondition code of�����and������of����� �.

Solution: None required.

MPSTCPY59 MPSTCPY62

44 MPST Messages and Codes Manual – Version 2.04

�������� ������������ �������������� � ������������ ������������ ��

Explanation: A unit check was posted due to end of data beingdetected on the cartridge tape. This is an excepted error. Thetype of pass (����) is����for a write pass,�����for a readforward pass, or�����for a read backward pass.

Solution: None required.

��������� ������������ �������� ��������� ����� �������������

Explanation: A pass has been started on test device������ataddress������with volume serial number��� ��. The type ofpass (����) is�����for a read forward pass,�����for a readbackward pass, or����for a write pass.

Solution: None required.

��������� ������������ ���������������� ����� ��������������� ���� �������������������������� ������ �������������������������� ������� ������������ ���������������� �������� ���������� ������ ��������

Explanation: A pass has ended on test device������ataddress������with volume serial number��� ��. The type ofpass (����) is�����for a read forward pass,�����for a readbackward pass, or����for a write pass.

The start and end date and times, as well as the elapsed time forthis pass, are listed.

Solution: None required.

MPSTCPY63 MPSTCPY91

45 Chapter 5. MPSTCPY

�� !��% � ""!��������� �������"� ������� ����#����% ���������� �������������#��������������� ��������

Explanation: This message always follows message��� ��.

Solution: None required.

�� !��% � ""!���������!������!����"��!���������!�����!%���#������!��������������������������$�������!

Explanation: A cartridge tape written in 3480–2 XF format ismounted on device������at address������and the device doesnot support 3480–2 XF format.

Solution: None required.

�� !��%�� ���!���� !��%���!�����""!�������!����%� ��&'�����

Explanation: Data on output device������will be destroyedby������ .

Solution: Respond to the message:

� Enter�%� �to continue������ . The data currently onthe output tape will be destroyed when the data on theinput tape is copied to the output tape.

� Enter����to drop the output device. The data currently onthe output tape will not be destroyed nor will theinformation on the input tape be copied to the output tape.

�� !��%� ������!���������������

Explanation: The parameter (����) is either coded incorrectlyor is invalid for the��������command for the������ function.

Solution: Re-enter the��������command using the correctparameter.

MPSTCPY96 MPSTCPY98

46 MPST Messages and Codes Manual – Version 2.04

��������� �� ���������������������������

Explanation: The��������command����������was issued to���� . The valid��������commands for����� �followthis message.

Solution: None required.

��������� ����������������������������������������

Explanation: The������������������is not supported by the���� �function.

Solution: None required.

��������� ��������������

Explanation: This message is issued in response to a�������

����������command requesting the current value of���������.

Solution: None required.

47 Chapter 6. MPSTDEF

Chapter 6. MPSTDEF

DEFINE Messages

All MPST functions and diagnostics use standard I/O operationchecking routines and these routines issue standard messages forerrors. Error message numbers are issued according to whichfunction or diagnostic was being run when the error occurred.

Hint: To make finding the messages easier, both the messagenumber and the message text are bold.

The following messages are issued for�������:

MPSTDEF00 MPSTDEF05

48 MPST Messages and Codes Manual – Version 2.04

����� ��� � ���

Explanation: The��������function is executing.

Solution: None required.

����� ��� ��� � �� �����������

Explanation: The parameter (����) is either coded incorrectlyor is invalid for the��������function.

Solution: None required.

����� ��� � ���� ����� � �������� ���� �

Explanation: A required parameter for the��������functionwas not specified.

Solution: Reissue the��������function with the requiredparameters.

����� ��� ���� ��������� ���� ��� �

Explanation: This DD name�������has already been defined.

Solution: None required.

����� ��� � ��� �������� ���� ��� �

Explanation: This device address ���� has already beendefined.

Solution: None required.

����� �� � ��� �������������������� ��� ��� ���� ���������

Explanation: This device�����is not supported by the�������function.

Solution: None required.

MPSTDEF06 MPSTDEF12

49 Chapter 6. MPSTDEF

������ �� ������������������� ����������������

Explanation: The type��DD card specified is invalid for thisdevice���.

Solution: Correct the DD card type.

������ �� ����������������� ������������������

Explanation: The device at address������is not defined to theoperating system.

Solution: ����the device to the current device definitions.

������ �� ����������������������������� ����������

Explanation: A type 3 or 4 DD card was specified and the dataset name does not match type 3 or 4 patterns.

Solution: None required.

������ �� ����������� �������������

Explanation: The device at address������failed to open.

Solution: None required.

������ �� ������������������������������������

Explanation: Device������could not be allocated, �������are:

� �������� ��������� ����—The������function adds offline/unassigned devices to the currentdevice definitions.

� �������� �������������� �—The device is offlinebut it is in use by another program that allocates offlinedevices.

� � ��������—An attempt to assign the device failed.

Solution: None required.

MPSTDEF13 MPSTDEF18

50 MPST Messages and Codes Manual – Version 2.04

�������� ������������������������� �

Explanation: An attempt to obtain storage for a Data ExtentBlock (DEB) failed.

Solution: None required.

�������� �����������������������������

Explanation: The maximum number of devices (eight) havebeen defined.

Solution: None required.

�������� ������������������������������������������

Explanation: DD name�������has been defined for the deviceat address������for a type���DD card.

Solution: None required.

�������� ��������������������������������������������������������

�������������������

Explanation: This message lists the devices currently definedby the��������function.

� �������is the device’s DD name.

� �����is the device address.

� ��is the DD card type.

Solution: None required.

MPSTDEF55 MPSTDEF58

51 Chapter 6. MPSTDEF

������� ���������������������� ����������������� ��������

Explanation: The��������function requires confirmation thatdevice������can be initialized.

Warning: If you respond���(yes), all data currently on thisdevice will be destroyed. Refer to message��������.

Solution: Respond to the message:

� ��to continue device initialization.

� ��to terminate.

������� ���������������� ������� ������������������ ��������������

Explanation: Device������must be varied offline to all othersystems.

Solution: Vary device������offline. Once the device has beenvaried offline, enter any character from the operator console tocontinue��������function execution.

������� ������������������������������������������� �������

Explanation: The��������function requires confirmation thatthe data on the volume mounted on device������can bedestroyed.

Solution: Respond to the message:

� ��if the data can be destroyed.

� ��if the data cannot be destroyed.

STOP

MPSTDEF59 MPSTDEF99

52 MPST Messages and Codes Manual – Version 2.04

��������� �� �����������������������

Explanation: The�������parameter was specified and noconfirmation for initialization or data destruction will be, or was,requested.

Solution: None required.

��������� ������ � ����������� ��� �������

Explanation: Write to offline DASD is not yet allowed. Thisis a future enhancement.

Solution: DASD devices must be online.

53 Chapter 7. MPSTGSA

Chapter 7. MPSTGSA

Generate Stand-alone Programs (GENSAPGM) Messages

All MPST functions and diagnostics use standard I/O operationchecking routines and these routines issue standard messages forerrors. Error message numbers are issued according to whichfunction or diagnostic was being run when the error occurred.

Hint: To make finding the messages easier, both the messagenumber and the message text are bold.

The following messages are issued for the Generate Stand-alonePrograms Function:

MPSTGSA00 MPSTGSA06

54 MPST Messages and Codes Manual – Version 2.04

��������� �����������������������������

Explanation: The ������ (Generate Stand-Alone Programs)function of MPST is executing.

Solution: None required.

��������� ����������������������

Explanation: The parameter (����) is either coded incorrectlyof is invalid for the ������ function.

Solution: Enter the correct parameter.

��������� ����������������������������

Explanation: An MPSTSAE IPL������is being generated.�����can be����, ���, or ����.

Solution: None required.

��������� ���������� �������������

Explanation: An open for file�������was unsuccessful.

Solution: Check the job EXECs. Verify that the referenced datasets exist.

��������� ����������������������������������

Explanation: Either IPL text (other than MPSTSAE IPL text)or user volume labels exist on the MPSTSAE IPL disk volume.The ������ function cannot replace non-MPSTSAE IPL text.MPSTSAE IPL text will not be written to the volume.

Solution: Obtain a different disk volume.

MPSTGSA07 MPSTGSA12

55 Chapter 7. MPSTGSA

�������� ����������� ������������������� �

Explanation: A permanent error has occurred. The errorindicated in messages�� ��������and�� ��������could notbe successfully retried.

Solution: Obtain different input and output devices.

�������� ����������� ������������������������

Explanation: The ����� �� function completed successfullyand an MPSTSAE IPL tape, disk or minidisk was created.

Solution: None required.

�������� ����������� ����������������������������

Explanation: The ����� �� function did not completesuccessfully. No MPSTSAE IPL tape, disk or minidisk wascreated. A prior message should indicate why the function wasunsuccessful.

Solution: Check� ��������file, correct the problem andrerun the ����� �� function.

�������� ������� ������������������������������������������

Explanation: The������ �����parameter specified by thedefined device is not a 3330–1, 3330–11, 3350, 3375, 3380 or3390 type device.

Solution: Obtain correct disk type and rerun the ����� ��

function.

MPSTGSA13 MPSTGSA14

56 MPST Messages and Codes Manual – Version 2.04

��������� ��������������������������������������������������������������������������or����������������������������� ����������

Explanation: Either a default control card set has just beencreated or the control card set contains no cards.

Solution: None required.

��������� ���� ����������������������

Explanation: The default control card set just created had aninvalid format.

Solution: Correct the control card set format.

MPSTGSA15 MPSTGSA15

57 Chapter 7. MPSTGSA

�������� ������������ ����� ��� ��� ������������� ��� �����������������������������������or��������������� �������������������

Explanation: A write to the IPL minidisk, at device address4FE, failed.

� ������—the last seek address.

� ����—the last Search ID Equal argument.

� �������—the count field of the record that could not bewritten.

� ����—the start block.

� ���—the number of blocks.

Solution: Check the following:

� When ��=� and �=��, device 4FE is not attached.Ensure that the device at address 4FE is defined and retry��������.

� When ��=� and �=��, device 4FE is busy or has aninterrupt pending. Retry ��������.

� When ��=� and �=��, unit status contained unitexception. Report this error to CSE Software Support.

� When ��=� and �=��, channel status contained incorrectlength. Report this error to CSE Software Support.

� When ��=� and �=��, a permanent I/O error occurred oran unsupported device was specified. �����is sense bytes0 and 1.

If the sense data is zero or it indicates a programmingproblem (such as command reject or no record found),report the error to CSE Software Support.

If the sense data indicates a device error (such as a datacheck or an equipment check), retry ��������.

MPSTGSA16 MPSTGSA19

58 MPST Messages and Codes Manual – Version 2.04

���� ���� �������������������������������

Explanation: The input data set specified by the �� ��� DDcard or ������� does not contain valid input for MPST������� or the input data is for the wrong version of MPST.

Solution: Check the following:

� Check the �� ��� DD card or �������.

� Verify that the correct tape is mounted.

� Increase the number of cylinders on the 4FE device andretry �������.

���� ���� �������������������������������������������or��������������������

Explanation: Either an active or alternate control card set hasjust been created or the control card set contains no cards.

Solution: None required.

���� ���� ���������������������������������������or������������������������

Explanation: Either a default device definition card set has justbeen created or the device definition card set contains no cards.

Solution: None required.

���� ���� ����������������������

Explanation: The default device data set just created had aninvalid format.

Solution: Correct the device definition format and rerun�������.

MPSTGSA20 MPSTGSA21

59 Chapter 7. MPSTGSA

�������� ����� ��� �������������� ��� �������������������or����� ��� ����������������

Explanation: Either a general help card set has just beencreated or the general help card set contains no cards.

Solution: None required.

�������� �������� ����������������� �������������������or�������� ����������������

Explanation: Either a StorageTekFRIEND help card set hasjust been created or the StorageTekFRIEND help card setcontains no cards.

Solution: None required.

60 MPST Messages and Codes Manual – Version 2.04

61 Chapter 8. MPSTINT

Chapter 8. MPSTINT

Attention Interrupt Messages

All MPST functions and diagnostics use standard I/O operationchecking routines and these routines issue standard messages forerrors. Error message numbers are issued according to whichfunction or diagnostic was being run when the error occurred.

Hint: To make finding the messages easier, both the messagenumber and the message text are bold.

The following messages are issued for Attention Interrupt:

MPSTINT20 MPSTINT40

62 MPST Messages and Codes Manual – Version 2.04

��������� ������������������������������������������������������

Explanation: MPST device ���� is running under MVS/OSand is an attention interrupt type device. The ����������

���� has no empty slots to support this device.

Solution: None required

��������� ����������������������������������������������������������

Explanation: No path was found for device ����.

Solution: To continue, vary a path �� for device ���� and reply�. To cancel, reply .

��������� ������������������������������ ���������

Explanation: The current test device has been determined to bea VIO (virtual input output) device and is not supported byStorageTek MPST.

Solution: None required.

63 Chapter 9. MPSTLEX

Chapter 9. MPSTLEX

Library Storage Module Exerciser (LSMEXER) Messages

All MPST functions and diagnostics use standard I/O operationchecking routines and these routines issue standard messages forerrors. Error message numbers are issued according to whichfunction or diagnostic was being run when the error occurred.

Hint: To make finding the messages easier, both the messagenumber and the message text are bold.

The following messages are issued for the Library StorageModule (LSM) Exerciser:

MPSTLEX00 MPSTLEX02

64 MPST Messages and Codes Manual – Version 2.04

��������� ��������������������

Explanation: The library exerciser���������has started.

Solution: None required.

��������� �������������������������

Explanation: The parameter (���) is either coded incorrectlyor is invalid for the���������function.

Solution: Enter the correct parameter.

��������� ���������������� ���������������������������������

Explanation: The cartridge tape drive�������at address����with volume serial number ���� configured without error.

Solution: None required.

MPSTLEX03 MPSTLEX03

65 Chapter 9. MPSTLEX

��������� ������������������������������������������������������������������������������������������������������������������

������������������������������������������ ����������������������������������������������������������������������������������������������������������������������������������������� ������������������������������ ������������������ ���������������������

Explanation: The�������for this execution of���������isprinted. The number of passes executed and the number ofrecords and tape marks processed is listed along with the totalnumber of compare, sequence, and temporary and permanentread and write errors. The total number of bytes transferred andthe number of bytes written and read is also listed.

Solution: None required.

MPSTLEX04 MPSTLEX07

66 MPST Messages and Codes Manual – Version 2.04

��������� �����������������������������������

Explanation: The� ��������parameter (����) is invalid.

Solution: Enter the correct parameter.

��������� �����������������������������������������������������������

Explanation: A��������for a portion of memory to be usedfor data comparison failed.

Solution: Increase the size of the region or partition that MPSTis executing in and re-execute MPST.

��������� ���������������������������������������

Explanation: An attempt to��������more than the maximumnumber of cartridge tape drives to��������failed. Message� ������ displays the failing drives.

Solution: Reduce the number of cartridge tape drives beingdefined. Up to a maximum of sixty-four drives can be defined.

��������� �������������������������������

Explanation: An error occurred on device�������whileprocessing command ���. Message � ������ follows thismessage.

Solution: None required.

MPSTLEX08 MPSTLEX09

67 Chapter 9. MPSTLEX

���� ��� ��������������������������������������������

Explanation: Device�������at address�����was notconfigured. ������for not configuring:

� �����������������������������—The device wasassigned to another path by the HOST CPU.

� � �����������—A test sequence with a write pass wasspecified but the cartridge is file protected. No testing willbe done on this device.

� ���������—An I/O error occurred during configuration.The error is described in message ���� ����.

� ������� ��—An open for the device failed. Verify thatthe DD card is coded correctly.

� ��� ��� ��������������� ���—The cartridge volumemounted on this device contains a valid OS tape label.Testing will not be done on this device.

� ������������������������—The test device DD cardfor this DD name does not define a cartridge device.Verify that the DD card is correctly coded.

Solution: None required.

���� ��� ����������������� ����������� �����

Explanation: The maximum number of����������or������cell locations was exceeded and the�� ������terminates.

Solution: Reduce the number of�������or����������entries.Up to 200 each is allowed.

MPSTLEX10 MPSTLEX13

68 MPST Messages and Codes Manual – Version 2.04

�������� ��������������������

Explanation: The������specified for the����� ��parameterwas invalid.

Solution: �����must be between 1 and 9999 minutes.

�������� ��������������������������������������

Explanation: All passes specified for device�������at drive����with volume serial number������have completed.Testing has terminated on that device for the cartridge withvolume serial number�����.

Solution: None required.

�������� ��������������������������������������������

Explanation: �������has detected that a������commandwas entered at the operator’s console. Testing on test device������at address�����with volume serial number������hasbeen stopped.

Solution: None required.

�������� �������������������� ���������������� ��� ��

Explanation: Testing on test device�������at address����with volume serial number������has been terminated due toa permanent error.

Solution: None required.

MPSTLEX14 MPSTLEX18

69 Chapter 9. MPSTLEX

��������� ��������������������������������������� ��������������������������������

Explanation: The��������parameter was entered and nomemory was available for the drive data buffer. The mountsrequested will not be performed.

Solution: If intervention is required, correct the problem andrestart the program.

��������� �����������������������������

Explanation: The LSM id (��) for the������parameter wasinvalid.

Solution: The LSM id must be between����and���.

��������� ���������������������������

Explanation: No CAP panel was found for LSM���.

Solution: This error indicates either an LMU configurationerror or a hardware error.

��������� ���������� ��������������������

Explanation: This message is issued at the end of�� ����

and indicates the number of times the cleaning cartridge wasused.

Solution: Mark the cleaning cartridges indicating the number ofpasses.

MPSTLEX19 MPSTLEX20

70 MPST Messages and Codes Manual – Version 2.04

���� ��� ������������ ��������

Explanation: Dynamic device definition has failed on drive����.

Solution: Check availability of device and retry.

���� ��� ������������ ������������������������������������������������������� �����������������

Explanation: The message identifies the tape drive that createdthe cartridge being read and the tape drive reading the cartridge.� ����is the volume serial number of the cartridge.

The drive reading the cartridge is identified by:

� �����—The tape drive’s address.

� ����—The DD name.

The drive that created the cartridge is identified by:

� �����—The tape drive’s address.

� ����—The DD name.

� �������—The control unit’s serial number.

� ��������—The tape drive’s physical address.

� ������—The tape drive’s logical address.

If the current pass is a read forward, ����and������identifywhen the write pass started on the creating tape drive.

If the current pass is a read backward, ����and������identifywhen the write pass ended on the creating tape drive.

Solution: None required.

MPSTLEX21 MPSTLEX24

71 Chapter 9. MPSTLEX

��������� ���������������������� ������������������ ��������������

Explanation: Incorrect����� ��was received for an I/Ooperation for device�������at drive�����during a����.

Solution: None required.

��������� ���������������������������������� �� ������� ��������� ���������������

Explanation: A read forward pass is being executed on testdevice�������at address�����with volume serial number�����. The BOT label on the cartridge is not a BOT label that�������would write on a test volume. Testing on the deviceterminates.

Solution: None required.

��������� ������������������������������

Explanation: A data record was expected but an EOT label wasread on a read forward pass of the cartridge on test device������

at address�����with volume serial number������. (The tapemark separating the data records and the EOT record wasmissed.) Testing on the device terminates.

Solution: None required.

��������� ���������������������������������� �� ��

Explanation: The cartridge on test device�������at address����with volume serial number�������mounted is missingthe EOT label that��������writes on a test volume. Testingon the device terminates.

Solution: None required.

MPSTLEX25 MPSTLEX27

72 MPST Messages and Codes Manual – Version 2.04

��������� ����������������������������������������� �����������������

Explanation: The number of blocks read (����) does notcompare with the number of blocks written ( ����) as listed inthe EOT label for the cartridge on test device������at address����with volume serial number�����. This is the equivalentof an����������. Testing on the device continues.

Solution: None required.

��������� �������������������������������������� ��

Explanation: A read backward pass is being executed on thecartridge on test device������at address�����with volumeserial number������mounted. The first record read was notthe EOT label, as expected; or the EOT record was not foundafter skipping a maximum of three tape marks. Testing on thedevice terminates.

Solution: None required.

��������� ����������������������� ���������������������

Explanation: A read backward pass is being executed on testdevice������at address�����with volume serial number�����mounted. The EOT label was read successfully but thenext record on the cartridge was not the tape mark preceding theEOT record. Testing on the device terminates.

Solution: None required.

MPSTLEX28 MPSTLEX30

73 Chapter 9. MPSTLEX

��������� ��������������������������������

Explanation: A read backward pass is being executed on testdevice�����at address������with volume serial number�����mounted. A data record was expected but a BOT labelwas read. (The tape mark separating the data records and theBOT record was missed.)

Solution: None required.

��������� ���������������������������������� �� ����

Explanation: The cartridge on test device�����at address�����with volume serial number������mounted is missingthe BOT label that��������would write on a test volume.Testing on the device terminates.

Solution: None required.

��������� ������������������������������������������ ���

Explanation: The last pass executed on test device�����ataddress������with volume serial number������mounted wasnot a write pass or a read forward pass. A read backward passcannot be executed.

The read backward pass is skipped and testing on the devicecontinues.

Solution: Modify the����������parameter.

MPSTLEX31 MPSTLEX35

74 MPST Messages and Codes Manual – Version 2.04

��������� ���������� ����������� ���� ��������������������������������������������������������

Explanation: A record was read on test device�����ataddress�����with volume serial number� �����mounted thatwas not the length expected. ��������expected record number����to have�������bytes but������bytes were received.

Solution: None required.

��������� ����� ������������������������������������� ��

Explanation: At initialization more cartridges were found thancan fit into the CAP.

Solution: None required.

��������� ��������� ������������������

Explanation: The������ ���parameter entered (��) isinvalid.

Solution: Enter the correct parameter.

��������� ���������� ��������������������������������� �������������������������� ��������������

Explanation: A sequence error occurred on test device����

at address�����with volume serial number� �����mounted. �������expected�������but received�����.

Solution: None required.

MPSTLEX36 MPSTLEX39

75 Chapter 9. MPSTLEX

����� ��� ������������ ���������� ���������� ����� ��������������������� ���������������� ������

Explanation: The record (���) read on test device�����ataddress������with volume serial number���� ���had incorrectid fields. The first four bytes������did not match the last fourbytes�����.

Solution: None required.

����� ��� ������������ �������������� ������ ���

Explanation: A short record was read on test device�����ataddress������with volume serial number���� ���mounted. Adump of the record follows.

Solution: None required.

����� ��� ������������ ������ �� �� � ������ �� �� ��� ������������ � �� �������

Explanation: A sequence error occurred on test device����

at address������with volume serial number���� ���mounted. ��������expected record�������but read record������

Solution: None required.

����� ��� ������������ ����� ���������

Explanation: The current compare record for device�����ataddress������with volume serial number���� ���is displayed.

Solution: None required.

MPSTLEX41 MPSTLEX43

76 MPST Messages and Codes Manual – Version 2.04

�������� �������������������������������� ������

������� ������������ ���������������� ����������������������������������������������������������������������������

Explanation: A write pass has been completed for device������at address������with volume serial number�����.The summary report for the write pass follows this message.

Solution: None required.

�������� ��������������������������������������������

���������������������������������������������������������������������������������������������������

Explanation: A read forward pass has been completed fordevice�������at address������with volume serial number����. The summary report for the read forward pass followsthis message.

Solution: None required.

MPSTLEX44 MPSTLEX49

77 Chapter 9. MPSTLEX

��������� �������������������������� �������������������

��������������������������������������������������������������������������������������������������������������������

Explanation: A read backward pass has been completed fordevice�����at address������with volume serial number����. The summary report for the read backward pass followsthis message.

Solution: None required.

��������� ��������������������������������� ����������������������������� ���

Explanation: A read forward pass has started for device����

at address�����. The cartridge������was written in ICRCformat and the drive is not ICRC capable.

Solution: None required.

��������� �������������������������������������� �������������

Explanation: Device������has been defined to to the�������function using the����� ��parameter, but was notdefined to MPST. I/O will not be performed on this device.

Solution: If you want to perform I/O on this device, the devicemust defined.

MPSTLEX51 MPSTLEX51

78 MPST Messages and Codes Manual – Version 2.04

�������� ������������ ������������������� ������������������������������������������������� ����� ������������������������������������������������������������

Explanation: A permanent error has occurred on test device������at address������with volume serial number�� ���mounted. Testing on the device terminates.

� ��������—The record number of the record on whichthe error occurred.

� ���������—The number of bytes transferred at thetime of the error.

� ����������—The number of times the operation hasbeen retried.

� �������—The channel command being executed.

� �������� ��—The SIO condition code.

� �������������—The unit and channel status for CCW.

� �����—The CPU ID of the CPU on which the erroroccurred.

� ���������—The actual channel path on which the erroroccurred.

� ���������—The sense bytes.

� �����������—A message describing the error. Somepossible messages and their meanings are:

� ������������������—The channel status byte ofthe CSW indicated a channel-type error.

� �������������—The event control block (ECB)completion code was not 7F (no error) or 41(permanent error). Any other ECB code is a fatalerror.

� ����������� —The equipment check bit is setin the channel status.

MPSTLEX53 MPSTLEX54

79 Chapter 9. MPSTLEX

� ��������������������—The error was not a datacheck or an overrun. Data checks and overruns areretried. All other errors are considered permanent.

� ������������������—Read error recovery failedto recover from a temporary read error. The error isnow a permanent error.

� �������������������—Write error recoveryfailed to recover from a temporary write error. Theerror is now a permanent error.

� �����������������—The failing CCW could notbe determined and no recovery action could be taken.

Solution: None required.

��������� �����������������������������������������������

Explanation: Following a sequence error,�������attemptsto get back in sync by resetting the record expected based uponthe record just processed. If the record read is more than four offof the record expected, the error is too great to correct in thismanner.

Solution: None required.

��������� ������������������������������������������������������������������ ������������������� ��

Explanation: The�������� ���command issued to device�����at address������with volume serial number������mounted failed with��������.

Solution: None required.

MPSTLEX55 MPSTLEX61

80 MPST Messages and Codes Manual – Version 2.04

��������� ������������������������������������ ������������������������������������� ��

Explanation: An error occurred on device�������at address�����with volume serial number������. The ERPA code of���is unsupported.

Solution: Notify CS Software Support of this message and givethem the sense data.

��������� �������������������������� ���������������������� ��

Explanation: The buffered log overflowed for device�������ataddress������with volume serial number������. The logcounters have been added to the statistics.

Solution: None required.

��������� ������������� ����� ����������������������������������������������� ����������

Explanation: ���is� ��for a read forward pass,� ���for aread backward pass, or�� ��for a write pass. This messageprints if�� ����is active.

Solution: None required.

��������� ������������������������ �����������������������

Explanation: A pass has been started on test device�������ataddress������with volume serial number������. The type ofpass ( ��) is� ��for a read forward pass,� ���for a readbackward pass, or�� ��for a write pass. ���������followsthis message.

Solution: None required.

MPSTLEX62 MPSTLEX68

81 Chapter 9. MPSTLEX

��������� ������������������������ �����������������������

Explanation: A pass has ended on test device������ataddress������with volume serial number������. The type ofpass (�� �) is��� �for a read forward pass,����for a readbackward pass, or�����for a write pass.

Solution: None required.

��������� ������������������ ����������������������� ����������� ����������������� ������������������

Explanation: This message always follows message���������.

Solution: None required.

�������� � ����� ����� ����������������������������������� ������ ����

Explanation: The cleaning cartridge is being cycled.

Solution: None required.

�������� ����������������� ������������������������ ��������������������������� ����� � ����� ����� ������ �����������������������������������������������������������������������������������������������������������������

Explanation: This message prints when the status (������) ofthe cartridges is requested by the����������parameter. Theoriginal CAP location (�����) and the current location(�����) are also displayed as part of this message.

Solution: None required.

MPSTLEX69 MPSTLEX72

82 MPST Messages and Codes Manual – Version 2.04

����� ��� ��������������������������� ��������� �� �����������������������

Explanation: This message prints when a CAP cycle is beingperformed with�������in effect.

Solution: None required.

����� ��� ���������� ����� ����������� ������������ ��� ���� ��� �

Explanation: The move count was equal to the mount count,enabling a mount transaction, but no drives were available. Thismessage prints if�������is active.

Solution: None required.

����� ��� ��������� ����������������������������� ������ �� ������������� ����������� ��������������������

Explanation: A mount transaction was issued and failed fordrive������volume serial number�������at���:��:���on��/��/�����for cartridge�� �, move number�� �.

Solution: None required.

����� ��� �������������������������� ��������� �� �����������������������

Explanation: The move for cartridge�� ��was completed fromLSM location��������to�������. This message prints if������is active.

Solution: None required.

MPSTLEX73 MPSTLEX76

83 Chapter 9. MPSTLEX

��������� ������������������������������������������������������������������ ����������

Explanation: The mount for cartridge�����was completed ondrive�����at LSM location����������from�������. Thismessage prints if� �����is active.

Solution: None required.

��������� �������������������������� ������ ��������������������������� ��������������������

Explanation: The�����failed for cartridge ��� from LSMlocation��������to�������.

Solution: None required.

��������� ���������������������������������������������� ����� �������������������

Explanation: The number of errors has exceeded the limit(���) of errors (��� ). The exercise terminates.

Solution: None required.

��������� ���������������������������������������������� ����� ������������������������������������������

Explanation: The number of errors has exceeded the limit(���) of errors (���� ) for cartridge tape drive����. Thisdrive will no longer be used.

Solution: None required.

MPSTLEX77 MPSTLEX80

84 MPST Messages and Codes Manual – Version 2.04

�������� ������������������������ ����������������������������������������������������������������

Explanation: The number of errors has exceeded the limit oferrors (������) for cartridge number���. This cartridge willno longer be used.

Solution: None required.

�������� ��������������������������������������������������������������������

Explanation: A fatal error has occurred on drive ����. Thisdrive will no longer be used.

Solution: If intervention is required, correct the condition andrestart the program.

�������� ��������������������������������������������������������������������������

Explanation: A fatal error has occurred on cartridge ��. Thiscartridge will no longer be used.

Solution: None required.

�������� �����������������������������������������������������������

Explanation: No cartridges were available for movement.Either no cartridges were placed into the CAP or all cartridgeswere removed from use due to errors. ��������terminates.

Solution: If intervention is required, correct the problem andrestart the program.

MPSTLEX81 MPSTLEX83

85 Chapter 9. MPSTLEX

����� ��� ����������� ������������������������ ����

Explanation: This message prints if������is active and move�������using cartridge���has started.

Solution: None required.

����� ��� ���� ����������������������� ������ � �� ��������

Explanation: ��� ��has ended.

Solution: None required.

����� ��� ������������������������ �������������� �������� � �������������� ��������������� ������ ��������������������� �� ����� ��������������������� ������ ������������������ ������ ����������� ������������������� ������ ������������� ������������������� ������ ���������������� ������������������� ���� � �������������������� �� � ������������������������������������ ��� ���������������������������������� ����������� ������ ������ � �������������������������������� ������ ������ � ����������������������������������� ������ ������ � �������������������� � ������ ������ � ������������������������ ��� ����� �

Explanation: The status for LSM �� is printed. Either��� ��has ended or the time specified by the�������

parameter has expired.

Solution: None required.

MPSTLEX84 MPSTLEX87

86 MPST Messages and Codes Manual – Version 2.04

������!� ���������������������������� ��������������

Explanation: ��������has ended and cleanup is moving thecartridges back to their original starting positions in the CAP.

Solution: None required.

������!� ����������������������������������������������� ������������

Explanation: The CAP has completed its audit and the 20cartridge volsers in the CAP are� �����if a label was read,����� if cartridge�����had no label, or���� ���if nocartridge was found in location�����.

Solution: None required.

������!� ���������������������������������������"��������������������������������������������������������������������������!�������������������������������������������������������������������������������������������������������������

Explanation: This message prints after all LSM summarymessages have been printed. The status reflects the timescomputed by the host CPU including any overhead time due tohost activity.

Solution: None required.

������! ���������������������������������������"��� ������������� ������

Explanation: LSM�����went not ready at���:��:�����/��/�����and will no longer be used.

Solution: None required.

MPSTLEX88 MPSTLEX92

87 Chapter 9. MPSTLEX

����� ��� ������������������������������������ �������������

Explanation: ����� �is cycling the cartridge back to theCAP and then moving the next CAP cartridge to be tested. Thisoccurs if����������was specified.

Solution: None required.

����� ��� �������������������������� � �

Explanation: The��������command�������was issued to����� . The valid��������commands for������ �followthis message.

Solution: None required.

����� ��� ����� ������ ���

Explanation: This message lists the number of cartridgesinserted into all possible LSM cells whenever the����

parameter is specified.

Solution: None required.

����� ��� ��� � �� �����������

Explanation: Parameter (����) is either coded incorrectly or isinvalid for the��������command for the������ �function.

Solution: Enter the correct��������parameter.

����� ��� ����������� ������������ � �����

Explanation: No LSMs were found available for generating arandom cell location. The current cartridge will not be moved,the consecutive error counter will increment, and the nextcartridge will be tried.

Solution: None required.

MPSTLEX93 MPSTLEX97

88 MPST Messages and Codes Manual – Version 2.04

������ �� ���������������!����� ���������������������������

Explanation: The panel� ����passed by the LSM status datawas invalid.

Solution: None required.

������ �� ������������������������������������ �������!������������������������

Explanation: This message prints if������is active and therandom locations generated were not available after 16 attempts.If����� ���is enabled, a location in another LSM will be tried.If����� ���is not enabled, this cartridge will be skipped forthis move.

Solution: None required.

������ �� ������������������������������������������������ �����������������

Explanation: The mount and passthru check counts were thesame. One of the counts was changed to��� .

Solution: None required.

������ � ���������������������������������������������������������������������� �����������������

Explanation: The passthru check count was an even multipleof the mount check count and has been changed to��� .

Solution: None required.

������ � ���� �������������������������!�������

Explanation: The��������parameter (����) is not supportedby the��������function.

Solution: Enter the correct��������parameter.

MPSTLEX98 MPSTLEX99

89 Chapter 9. MPSTLEX

�������� ��������������

Explanation: This message is issued in response to a� �����

����������command requesting the current value of���������.

Solution: None required.

�������� ���������������� ������� ����������������� ������������������������������������������ � � ������������������������������������� ���������� ����������� �

Explanation: The following conditions could effect thefunction of������ if:

� ������is run concurrently with the host softwarecomponent (HSC) there is a possibility that the HSC CAPtask will abend if it tries to reserve a CAP already reservedby MPST.

� MPST uses an empty cell just prior to HSC also using thatcell, HSC will try to eject the MPST cartridge.

� The HOSTID used by MPST is also being used by HSC,the LMU will alternate all messages and responsesbetween HSC and MPST.

� ������is run concurrently with LDL diagnostics, aconflict may occur causing LMU errors.

Solution: If the HSC command���������is issued for eachHSC HOSTID, the problem with a CAP being reserved isminimized.

Hint: If you want to continue running������, reply����tothis message.

90 MPST Messages and Codes Manual – Version 2.04

91 Chapter 10. MPSTLIB

Chapter 10. MPSTLIB

Library Mount (LIBMOUNT) Messages

All MPST functions and diagnostics use standard I/O operationchecking routines and these routines issue standard messages forerrors. Error message numbers are issued according to whichfunction or diagnostic was being run when the error occurred.

Hint: To make finding the messages easier, both the messagenumber and the message text are bold.

The following messages are issued for Library Mount:

MPSTLIB00 MPSTLIB05

92 MPST Messages and Codes Manual – Version 2.04

������ �� �� �����

Explanation: The����������program has been loaded andstarted.

Solution: None required.

������ �� ����������������������

Explanation: The parameter (����) is either coded incorrectlyor is invalid for the����������function.

Solution: Enter the correct parameter.

������ �� ����������� �������������������������������

Explanation: The maximum number of cartridge tape drives orrequests has been exceeded for the parameter (����) beingdecoded.

Solution: None required.

������ � �����������������������������������

Explanation: The parameter data entered is invalid.

Solution: Enter the correct parameter data.

������ � ������������������������

Explanation: The HOST tried to initialize the LMU and failed.The LMU is either not attached, not defined, or failed.

Solution: Issue the�����command to determine if the LMUexists.

������ �� �������������

Explanation: An error occurred while executing a transactionwith the LMU.

Solution: None required.

MPSTLIB06 MPSTLIB10

93 Chapter 10. MPSTLIB

������ �� ��������������������������������������

Explanation: The�����������is being sent to the LMU.This message prints if�������is active.

Solution: None required.

������ � ��������������������������������������������������

Explanation: The�����������is being resent to the LMU.This message prints if�������is active.

Solution: None required.

������ � ��� �������������������������������������������� ���������������

Explanation: The�����������was sent to the LMU and no����(acknowledge or response) was received from the LMU in����seconds. The sequence number for the transaction is #� �.

Solution: None required.

������ �� �������������

Explanation: An error occurred while executing a readfollowing an attention interrupt.

Solution: None required.

������ �� �����!���������������� ���������

Explanation: An interrupt was received from the LMU but the�����it presented was not recognized as valid data. Thismessage prints if�������is active.

Solution: None required.

MPSTLIB11 MPSTLIB16

94 MPST Messages and Codes Manual – Version 2.04

�������� �������� ������������ ���

Explanation: A message was received from the LMU.

Solution: None required.

�������� ��������������� ������������������ ����

Explanation: An interrupt was received from the LMU and theresponse set the error indicator.

Solution: None required.

�������� ������������������������� ���

Explanation: An invalid request was issued to�������.

Solution: Enter a valid request.

�������� ������������������������� �������

Explanation: An attempt to��������a drive failed because nomore drives are allowed.

Solution: Reduce the number of cartridge tape drives beingdefined. Up to a maximum of 64 drives can be defined.

�������� ����� �� ������������������������� ����

Explanation: A������ ��to��������for a cartridge tapedrive at address������failed because the drive was not defined.

Solution: �� !��the drive.

�������� ����� �� ����������������������������������

Explanation: A������ ��to��������to mount a cartridgeon drive������failed because a cartridge is already mounted onthat drive.

Solution: Mount the cartridge to another drive or issue a����"$!#/���!#�command to the drive.

MPSTLIB17 MPSTLIB22

95 Chapter 10. MPSTLIB

�������� ����������������� ������������ ������

Explanation: An interrupt was received from the LMU, and the�� �������is invalid.

Solution: None required.

�������� ������������������������ ������������������ �

Explanation: The format of the data in the��������� �received from the LMU is invalid.

Solution: None required.

�������� �������� ������������������������������

Explanation: A���������to���������to dismount acartridge on drive������failed because the drive is not mounted.

Solution: None required.

�������� ��������������������������������������

Explanation: The location����������is not a valid drivelocation in the LSM.

Solution: �� ����a valid location.

�������� ������������������������������������

Explanation: The location����������is not a valid celllocation in the LSM.

Solution: Specify a valid location.

�������� �������� �������������������

Explanation: The exchange request between drives�������and������ failed.

Solution: None required.

MPSTLIB23 MPSTLIB28

96 MPST Messages and Codes Manual – Version 2.04

��������� �������� ������������

Explanation: The������request between drives������and�����failed.

Solution: None required.

��������� ������ ����� ������������������

Explanation: An attempt to disband either the��������or���������LMU failed.

Solution: None required.

��������� ����������� ����� ����������

Explanation: An attempt to�� ��the cartridge from drive��� back to the last location for that cartridge failed.

Solution: None required.

��������� ��������������������������������

Explanation: The�����������data received from the LMUwas in error.

Solution: None required.

��������� �������������������

Explanation: An error occurred while executing a block����

to the LMU.

Solution: None required.

�������� ����� � ����������

Explanation: Drive�����has been defined.

Solution: None required.

MPSTLIB29 MPSTLIB32

97 Chapter 10. MPSTLIB

�������� ������������������������ �������������� ������������������������������������������������������������������

Explanation: This message only prints if��������wascalled by controls cards and the status of a cartridge haschanged.

Solution: None required.

�������� ����������������������������������������������

Explanation: The drive is unavailable at location���������.Possible���������are:

� �������� � ������������

� �����������

� ���������������

� �������

� ���������� � ������������

Solution: None required.

�������� �������������������

Explanation: LSM status indicates that LSM����is not ready.

Solution: None required.

�������� ������������ ������

Explanation: LMU configuration data indicates that LSM���is not configured.

Solution: None required.

MPSTLIB33 MPSTLIB37

98 MPST Messages and Codes Manual – Version 2.04

��������� ����������� ������������� �������

Explanation: A� �������command (������or�������)issued to LSM����failed.

Solution: None required.

��������� ������������� �����������������

Explanation: A������was issued to a drive at LSM location�������and no drive is located there.

Solution: None required.

��������� �����������������������������������������������������������

Explanation: A������������was sent to the LMU and isbeing retried.

Solution: None required.

��������� ����������������������� ����� ��������

Explanation: A������������request issued to drive����failed.

Solution: None required.

��������� ����������������� ��������������������������������������������

Explanation: A cartridge movement (� �) transaction is aboutto be issued but there is no active cartridge at location����.

Solution: Specify an occupied location.

MPSTLIB38 MPSTLIB42

99 Chapter 10. MPSTLIB

��������� ���������������������� ����������������� �������������������������

Explanation: A������request transaction was issued forcartridge�� ��at LSM location��������and the requestfailed.

Solution: None required.

�������� ����� ���������� �����������������������

Explanation: Cartridge�� ��was successfully moved fromLSM location��������to LSM location�������. Thismessage prints if������is active.

Solution: None required.

��������� ������������������ ���������� �����������

Explanation: The exerciser was trying to put cartridges backinto the CAP. Cartridge �� ��at LSM location��������wasnot entered into the CAP.

Solution: None required.

��������� ���� �����������������������������������

Explanation: A �������or��������command issued toLSM����CAP�� ��failed.

Solution: None required.

��������� ����������� ����������������������������� ���������������� ����� ������� ����� �

Explanation: A���������(audit)�� ����issued for cells���–���for LSM����failed. The responses received resultingfrom the request is�� ��for both�������� ���and�� ������������ ��.

Solution: None required.

MPSTLIB43 MPSTLIB47

100 MPST Messages and Codes Manual – Version 2.04

��������� �����������"������� !����������

Explanation: An�������or������command issued to LSM�CAP����failed.

Solution: None required.

��������� ������������������ �

Explanation: A���������� ����������transaction has failedfor�������.

Solution: None required.

��������� ������"����������������� ��������"��������������

Explanation: The LSM exerciser has started or ended and thetest cartridges must be inserted into or removed from�the CAPat LSM location�.

Solution: Insert or remove the cartridge.

��������� �������������������� ���������������������� �� ��������� ������������������� ������� ��

������� ����������������� ����� �������������������� ������

����������������� ����

Explanation: The��������audit has ended for LSM�.

Solution: None required.

�������� ��� ��������� "�����

Explanation: The CAP door has been opened or closed inresponse to an�������or������command.

Solution: None required.

MPSTLIB48 MPSTLIB52

101 Chapter 10. MPSTLIB

�������� �������������"��� �

Explanation: The cartridge listed in the previously displayederror message was lost or stuck.

Solution: Manually locate the cartridge.

�������� ����������� ���������� ����� �������������

Explanation: When cartridge tape drive������was undefinedafter a���� ����transaction was attempted, drive������wasfound active.

Solution: None required.

��������� ��������!� ����������������������

Explanation: MPST waited for�����wait periods fortransaction sequence������to either complete or fail. Thismessage prints if������is active.

Solution: None required.

��������� ������ ����������������������

Explanation: The acknowledgement for transaction sequence�����has been lost and a response was detected for thetransaction request. The transaction will be completed as if����

was received.

Solution: None required.

��������� �������������!����������������������

Explanation: CAP�����cannot be reserved to HOSTID���because the specified CAP is already reserved to another HOSTid.

Solution: None required.

MPSTLIB53 MPSTLIB57

102 MPST Messages and Codes Manual – Version 2.04

��������� ������������������ �������

Explanation: CAP�����was successfully reserved to HOSTID��.

Solution: None required.

��������� �������������������� �������

Explanation: CAP�����was successfully released fromHOSTID���.

Solution: None required.

��������� �������������������� ��������������������������

Explanation: A CAP�������command from HOSTID���to CAP�����failed. The CAP is�������to anotherHOSTID.

Solution: None required.

��������� ������������������� ��� �����������������������������

Explanation: A CAP��� ��command was requested butfailed. The CAP is not reserved to the requesting HOST.

Solution: None required.

��������� ������������������� ��� �����������������������������

Explanation: A CAP���� �command was requested butfailed. The CAP is not reserved to the requesting HOST.

Solution: None required.

MPSTLIB58 MPSTLIB61

103 Chapter 10. MPSTLIB

������ � ���� ���������� ��������������������������

Explanation: A command was retried����times, but theLMU buffer is full.

Solution: None required.

������ � �������������������� "���!���� ���������������"��� � ������� �� � ������� � �����������������"������������� � ����������������"���������������� � ������������������ � ��������������� � ������������������ � ��������������������� � ����������������

Explanation: The status is listed for LSM���, and the statusfor all configured LSMs will be printed. ��������is:

� ���� or ������,

� ������������, or

� �����������.

Solution: None required.

������ �� ����������������������������� ����� �

Explanation: This message prints if�� ����is active. ��������is the block message and ����� ��is the first 23characters of the transaction.

Solution: None required.

������ �� ������������������������������� ����� �

Explanation: This message prints if�� ����is active. ��������is the block message and ����� ��is the first 23characters of the transaction.

Solution: None required.

MPSTLIB62 MPSTLIB66

104 MPST Messages and Codes Manual – Version 2.04

��������� ����������������������������������������������������

Explanation: The volser at cell�����had a mismatch for eitherthe first, second, or third pass of a verify request.

Solution: None required.

��������� ����������������������������������������

Explanation: No volser was found at cell location����.

Solution: None required

��������� ��������������������������������

Explanation: A CAP cycle is being performed with the�����������parameter active. CAP�����for LSM����is tobe opened and closed as part of the CAP cycle.

Solution: Open and close the CAP door.

��������� ����� ��������������������� ������������

Explanation: This message prints when a cartridge recoveryhas been issued. �������� will be one of the following:

� ��������������������������������

� �������������������� �����������

� ������������������������� ��������

� ���� ���������������� ���

Solution: None required.

MPSTLIB70 MPSTLIB73

105 Chapter 10. MPSTLIB

�������� ���������������������������� ���������������������������������������������

Explanation: This message prints at initialization of��������

or�������. ����is the level of firmware.

Solution: None required.

�������� ������������������

Explanation: An open error occurred on LMU�����.

Solution: None required.

�������� ����������������������� ���������

Explanation: An LMU switch was requested but only oneLMU is configured.

Solution: None required.

�������� ��������������������� ������������������������������������������������������������������

Explanation: This message prints at initialization of��������

or�������.

� ������is the address of the master LMU if dual LMU isrunning, or the address of the LMU if dual LMU is notrunning.

� ������is the address of the standby LMU if dual LMU isrunning.

Solution: None required.

MPSTLIB74 MPSTLIB77

106 MPST Messages and Codes Manual – Version 2.04

��������� ������������� ������������������� ������������ ����������������� ������

Explanation: A force or auto switch-over request failed withdual-LMU running.

� ��� �is the standby address.

� ��� �������is the type of switch-over failure thatoccurred.

Solution: None required.

��������� �����������������

Explanation: This message prints if a functional LMU cannotbe found.

Solution: None required.

��������� ���������������������������������������

Explanation: This message prints if�������is active. ��������will be one of the following:

� �����������

� ��������

� � ������

Solution: None required.

��������� ����������������������� �������������

Explanation: An LMU join request failed. The ��������������LMU at address���� �failed to join theHOST.

Solution: None required.

MPSTLIB78 MPSTLIB97

107 Chapter 10. MPSTLIB

�������� ����������� ��������������� ������������������������

Explanation: Communications between the master LMU andthe standby LMU have been re-established. The standby LMUstill failed to join with the HOST.

Solution: None required.

�������� ����������������������� �����������������

Explanation: An attention interrupt was received from thestandby LMU. This message prints if�������is active.

Solution: None required.

�������� ����������������������

Explanation: The parameter (����) is either coded incorrectlyor is invalid for the�������command for the ����� �function.

Solution: Enter the command using the correct parameter.

�������� ���������� ��������� ����������

Explanation: The�������command���������was issued to����� �. The valid�������commands for������ ��followthis message.

Solution: None required.

�������� ����������������������������� �����������������

Explanation: The��������������� is not supported by the����� ��function.

Solution: Enter the correct�������parameter.

MPSTLIB98 MPSTLIB99

108 MPST Messages and Codes Manual – Version 2.04

����� ��� ��������������

Explanation: This message is issued in response to a�������

��� ��command for the��������function and displays thecurrent value for the requested parameter.

Solution: None required.

����� ��� ���������������� �� ������� ����������������� ������������������������������������������� � � ������������������������������������� ���������� ����������� �

Explanation: The following conditions could effect thefunction of�������:

� If��������is run concurrently with the host softwarecomponent (HSC), there is a possibility of causing theHSC CAP task to abend if it tries to reserve a CAP alreadyreserved by MPST.

� If MPST uses an empty cell just prior to HSC also usingthat cell, HSC tries to eject the MPST cartridge.

� Also, if the HOSTID used by MPST is also being used byHSC, the LMU alternates all messages and responsesbetween HSC and MPST.

� If��������is run concurrently with LDL diagnostics, aconflict may occur causing LMU errors.

Solution: If the HSC command ���� �� is issued for eachHSC HOSTID, the problem is minimized.

Hint: If you want to continue running�������, reply����tothis message.

109 Chapter 11. MPSTLOK

Chapter 11. MPSTLOK

Library Look (LIBLOOK) Messages

All MPST functions and diagnostics use standard I/O operationchecking routines and these routines issue standard messages forerrors. Error message numbers are issued according to whichfunction or diagnostic was being run when the error occurred.

Hint: To make finding the messages easier, both the messagenumber and the message text are bold.

The following messages are issued for Library Look:

MPSTLOK00 MPSTLOK04

110 MPST Messages and Codes Manual – Version 2.04

��������� �����������

Explanation: Th����������program has been loaded andstarted.

Solution: None required.

��������� ����������������������

Explanation: The parameter (����) is either coded incorrectlyor is invalid for the���������function.

Solution: Enter the command using the correct parameter.

��������� ������������������������

Explanation: The parameter (����) is incomplete.

Solution: Enter the complete parameter.

��������� ��������� ������������������������������������������������������������������������

Explanation: The configuration for panels �� through �� islisted for LSM ��.

Solution: None required.

MPSTLOK05 MPSTLOK08

111 Chapter 11. MPSTLOK

�������� ����������� � � ���������������������������������������� � ����������������������������������� �������� ��� ����������������������#���������!������ ��� �������������������� � � ���� ����������������������������������������������������!������ ��� �������������������� � � ���� ���������� ��������� �������������!�����������������������������������������������������������

Explanation: The status of LSM �� is listed.

Solution: None required.

�������� ��"�� ��� ����������������� �����"���������������

Explanation: The maximum number of panel audit requests(200) has been exceeded.

Solution: Respecify the number of panel audit requests.

��������� ��"�� ��� ��������������� �����"����������������

Explanation: The maximum number of CAP audit requests(200) has been exceeded.

Solution: Respecify the number of CAP audit requests.

��������� ��"�� ��� �����������!����� �����"����������������

Explanation: The maximum number of cartridge tape driveaudit requests (200) has been exceeded.

Solution: Respecify the number of cartridge tape drive auditrequests.

MPSTLOK09 MPSTLOK13

112 MPST Messages and Codes Manual – Version 2.04

�������� ������������������ ���������������� �����

Explanation: The maximum number of CAP parameters (100),which result in CAP audit requests, has been exceeded.

Solution: Respecify the number of CAP parameters.

��������� ��������� �����������������

Explanation: The� ����command was entered by the operator.

Solution: None required.

��������� �������������������� ���!"� �������� ���������������������������������

Explanation: The CAP parameter entered (������) isinvalid for the�����������.

Solution: Use the������command to enter the correct���parm.

��������� ������������ �������������!"������������ ������������������������

Explanation: The panel list parameters found by the��������

function are corrupted.

Solution: Exit MPST and notify CS Software Support. Theprinter output should be retained and given to CS SoftwareSupport.

��������� ������������������������������������������� ������ �������������

Explanation: The panel number () entered for a 9740 drive isinvalid.

Solution: Respecify the panel number.

MPSTLOK17 MPSTLOK95

113 Chapter 11. MPSTLOK

�������� �������������� ������ �����

Explanation: ������tried to load the���������functionand failed.

Solution: Exit MPST and notify CS Software Support. Theprinter output should be retained and given to CS SoftwareSupport.

��������� ������������������������������� ������������ ����������������������������������������������

Explanation: The audit request has ended. The time to run, thenumber of cells that were actually audited, and the average timeper cell are listed.

Hint: Remember if� �����or� ������was specified, thetotal time and cell count is three times that requested.

Solution: None required.

�������� ����������������������

Explanation: The parameter (����) is either coded incorrectlyor is invalid for the command for the�������function.

Solution: Enter the command using the correct parameter.

�������� �������������������������������"$����������'"����������������������

Explanation: The�������function is ready to acceptcommands via the�%&!#�(�command. This message isrepeated, after the function processes input parameter, until an����parameter is received.

Solution: None required.

MPSTLOK96 MPSTLOK98

114 MPST Messages and Codes Manual – Version 2.04

��������� ��� ��� ��������������� �����

Explanation: The��������command����� ��was issued to�����. The valid��������commands for�������followthis message.

Solution: None required.

��������� � ������������������������ �������������������

Explanation: The������������������is not supported by the������function.

Solution: Enter the correct��������parameter.

��������� ��������������

Explanation: This message is issued in response to a�������

������command for the�������function and displays thecurrent value for the requested parameter.

Solution: None required.

MPSTLOK99 MPSTLOK99

115 Chapter 11. MPSTLOK

������ �� ������������������������� �������������������������������������������������������������������������������������������������������������������������������������������

Explanation: The following conditions could effect thefunction of������:

� If�������is run concurrently with the host softwarecomponent (HSC), there is a possibility of causing theHSC CAP task to abend if it tries to reserve a CAP alreadyreserved by MPST.

� If MPST uses an empty cell just prior to HSC also usingthat cell, HSC tries to eject the MPST cartridge.

� Also, if the HOSTID used by MPST is also being used byHSC, the LMU alternates all messages and responsesbetween HSC and MPST.

� If�������is run concurrently with LDL diagnostics, aconflict may occur causing LMU errors.

Solution: If the HSC command ����� is issued for eachHSC HOSTID, the problem is minimized.

Hint: If you want to continue running������, reply���tothis message.

116 MPST Messages and Codes Manual – Version 2.04

117 Chapter 12. MPSTMAN

Chapter 12. MPSTMAN

MPST Main Processing (MPSTMAIN) Messages

All MPST functions and diagnostics use standard I/O operationchecking routines and these routines issue standard messages forerrors. Error message numbers are issued according to whichfunction or diagnostic was being run when the error occurred.

Hint: To make finding the messages easier, both the messagenumber and the message text are bold.

The following messages are issued for MPST Main Processing:

MPSTMAN02 MPSTMAN06

118 MPST Messages and Codes Manual – Version 2.04

��������� �� ��������������������

Explanation: This is the last message issued by MPST prior tonormal termination. The highest return code encountered duringexecution was �. This return code (�) is returned to thesystem (calling program).

Solution: None required.

��������� ����������������������������������

Explanation: The last control card listed has requested anunknown function.

Solution: Correct the control card.

��������� �������������������������

������������������������������������������������������������������������������������������������������������������������������

������������

Explanation: The function�����started or ended at time���������and the return code for the last function was��. Thefunction performed����EXCPs to the test device andenvironmental sense data was received����times. If the testdevice is a 33XX type device, the last����occurrences ofenvironmental sense data are listed.

Solution: None required.

��������� ���������������������������

Explanation: The�������������option is in effect and theMPST online control card editor will be entered at the end of thecurrent control card string.

Solution: ������������will remain in effect until����������is specified.

MPSTMAN07 MPSTMAN08

119 Chapter 12. MPSTMAN

������ � ������ ����������������

Explanation: The��������option is in effect while a controlcard set is being processed. The current value of�����is thenumber of times to repeat the current control card set. Thismessage is issued each time the control card set is repeated.

Solution: Execution ends when the value of�����equals zero.

������ �������

Explanation: The following conditions could exist:

� A control card indicated that function parameters werecontinued on the next card, but an end of file occurredwhen MPST attempted to read the next card.

� The last control card contains more than 31 parameters orthe total of all parameter characters exceeds 512.

One of the following messages is displayed:

� �������������������������������

� ��������������� ���������������������

� ���������������������� ����������

� ����������������������������������������� �

�����

� ����������������������� ��������� ��� ���

�����

� ����������������������� �������������� �

� ��� ������

� ������ ��� ������������ ���

� ������� ������ ������

� ������������������������������������������

�������

Solution: Check for missing commas or missing blank spacesbetween parameters. Parameters must be separated by a commaor by blank spaces.

MPSTMAN10 MPSTMAN15

120 MPST Messages and Codes Manual – Version 2.04

��������� ���������������

Explanation: The parameter is coded incorrectly or is invalidfor the��������function.

Solution: Re-enter the��������command using the correctparameter.

��������� ��� ���� ����������

Explanation: The current settings of the��������functionparameters are listed.

Solution: Refer to the appropriate MPST Functions ReferenceManual for an explanation of the listed options

��������� �� ������� ����� ����� ������ ��������� ��

Explanation: The requested device or devices are not defined.

Solution: Redefine the requested device or devices.

��������� � � �������������

Explanation: The requested Sense ID data for DD name �����

is displayed.

Solution: None required.

��������� �� �������������

Explanation: The requested Read Device Configuration datafor DD name ����� is displayed.

Solution: None required.

��������� �� �������������

Explanation: The requested Read Configuration Data for DDname ����� is displayed.

Solution: None required.

MPSTMAN19 MPSTMAN20

121 Chapter 12. MPSTMAN

�������� ����� ����������������

Explanation: During open the DD card is missing for����� �.

Solution: Correct the DD card.

�������� � �������� ��������������������������������������������� ����������������������������������������������������������������������������������������

Explanation: The�������parameter of the�������functionwas specified. This message lists the I/O status for an I/Ooperation when it is posted as completed.

� ��������—The device address.

� ������—The ECB completion code.

� ������������������—The SIO condition code, the unitand channel status, and the residual byte count from theCSW.

� ��������—Sense bytes 0 and 1.

� �������—The IOB flag bytes.

� ��������������—The seek address in hex.

� ��� �����—The DASD file mask byte.

� ����������—The I/O appendages flag byte.

� �������—The CPU ID on which the operation occurred.If no error occurred, the � will be ��.

� ��������—The actual path used for the operation. If noerror occurred, the ��� will be ����.

� ��������������—The sense bytes, if available.

� �������������������—The command code, flag byte,and the byte count for each CCW in the CCW chain. Theformat of the last CCW executed is ������������.

Solution: None required.

MPSTMAN21 MPSTMAN21

122 MPST Messages and Codes Manual – Version 2.04

������ ������������ �������������������������� ������������������� ����

Explanation: The�������function������parameter wasspecified. MPST lists the results of a successful open request.

� ��—The DD name that was opened.

� ����—The device address

� �����—The volume serial number mounted on thedevice.

� ��—The device type.

� ������—The hexadecimal address of the cylinder.head atthe start of the first data set extent if a DASD device.

� ������—The hexadecimal address of the cylinder.head atthe end of the first data set extent is a DASD device.

� ����—The number of tracks in the data set extent.

Solution: None required.

MPSTMAN22 MPSTMAN25

123 Chapter 12. MPSTMAN

��������� �����������������������

Explanation: The�������function������parameter wasspecified. MPST indicates that a close request for device���

was successful.

Solution: None required.

��������� ���������������������������������������������

Explanation: Environmental data was detected for deviceaddress ����.

Solution: None required.

��������� �����������������������������������������������

Explanation: The missing interrupt handler (���) has posted anMPST I/O operation completed. This message is normallyfollowed by an error message from the MPST function that isexecuting on device�����.

Solution: Determine why the device lost the interrupt.

��������� ������������������������������������������������

Explanation: Environmental data was detected for device����. The sense�����contain the environmental data.

Solution: None required.

MPSTMAN26 MPSTMAN26

124 MPST Messages and Codes Manual – Version 2.04

��������� ��������������������������� ��������������������������������������������� �������������������������� ������������������� ������������ ���������������������������������������� ���������� ���� ��������� � �� ����������������������������������������������������� ��������������������

Explanation: The device at address������has caused a SIMrecord to be logged.

� �����������and���������—The data and time of theSIM.

� �� �����������—The DASD volser.

� ���������������—The device code.

� ������������������� —The device type and modelnumber.

� �� ��������������� —The controller type and modelnumber.

� ��������—The error code.

� ������������������������������—The severity code,SIM type, and an indicator that the SIM is repeated.

� ���� ���������� ������—The manufacturer andplant ID.

� ����� �� ��������� —The plant serial number.

� ���������—The SIM ID.

� �������������—The reference codes.

� �����������������—The ServiceTek sequence code.

� ����������—The message code.

� ��������������������—The message modifiers.

� ���������—The raw sense byte.

Solution: None required.

MPSTMAN27 MPSTMAN42

125 Chapter 12. MPSTMAN

��������� ������������������������������ ���������

Explanation: SMS VIO (Virtual Input Output) devices areconsidered to be non-StorageTek devices and are not supported.

Solution: Special ACS Routines must be provided by thecustomer to successfully run MPST/MVS in an SMS controlledinstallation.

��������� ����������������������������

Explanation: MPST has detected that a������command wasentered at the operator’s console. MPST terminates at the nextavailable stop point.

Solution: None required.

��������� �������������������������

Explanation: The control card file contained no control cards.

Solution: Verify that the SYSIN DD statement is present,correctly coded, and followed by one or more MPST functioncontrol cards.

��������� ������������������� ����������������

Explanation: The return code from the����������was greaterthan zero. This condition indicates an error that does not allowMPST to perform properly and MPST terminates immediately.Previous errors should have indicated the errors that resulted inthe return code being greater than zero.

Solution: Correct the errors and re-execute MPST.

MPSTMAN43 MPSTMAN70

126 MPST Messages and Codes Manual – Version 2.04

�������� ���������������������������������

Explanation: The return code from the last function executedwas greater than the return code allowed by the�� �����������

paramete. MPST terminates immediately.

Solution: None required.

�������� ������������������

Explanation: A���� �command was entered at the operator’sconsole and MPST operation terminates. All MPST controlcards may not have been processed.

Solution: None required.

�������� ��������������������������������������������

Explanation: MPST requires a response.

Solution: Enter the������command to stop the execution ofMPST or enter null to continue MPST execution.

�������� ��������������������������������������������������������

Explanation: The response to message� �������wasneither���� �nor null.

Solution: Enter������to stop the execution of MPST or null tocontinue MPST execution.

�������� ��������� ��������� ���������

Explanation: The��������command�������was issued to� ����. The valid��������commands for� ������followthis message.

Solution: None required.

MPSTMAN71 MPSTMAN99

127 Chapter 12. MPSTMAN

��������� ��� ��������������������� ��������������

Explanation: The� ����������������is not supported by the������function.

Solution: Enter the correct� ������parameter.

��������� �� ������ �������������������� ���������������������

Explanation: The� ������parameter������for the������function has been rejected. The control cards to be repeatedmust have been previously loaded into the control card buffer.

Solution: Re-run the operation with the correct control cardsource.

��������� ������� ������

Explanation: The�������function�����parameter wasspecified and trace point�����was encountered.

Solution: None required.

128 MPST Messages and Codes Manual – Version 2.04

129 Chapter 13. MPSTRLB

Chapter 13. MPSTRLB

Random Locate Block (RLB) Messages

All MPST functions and diagnostics use standard I/O operationchecking routines and these routines issue standard messages forerrors. Error message numbers are issued according to whichfunction or diagnostic was being run when the error occurred.

Hint: To make finding the messages easier, both the messagenumber and the message text are bold.

The following messages are issued for Random Locate Block:

MPSTRLB00 MPSTRLB03

130 MPST Messages and Codes Manual – Version 2.04

�������� ���������� �����

Explanation: The�����function will be executed on thedevices listed by message���������.

Solution: None required.

�������� ��� � �� ����������

Explanation: The parameter (���) is either coded incorrectlyor is invalid for the�����function.

Solution: Enter the correct parameter.

�������� ���� ������������������ �������������������� ����������������

Explanation: Device����at address�����with volumeserial number������configured without error.

Solution: None required.

�������� ������������������ ������������������� ����������� ������� �������������������������������������������� �� � ��� ��� ���������� �� ���� ���������� �� ��� ������� � ������� ������� � ������� ��� �� �������� ������� ������ ��� ����������� ����������������� �� ������������� ����������� ������� ��� ��� �������������� ���� ����������������� �� ���������� ������� � ������������������ ��

MPSTRLB03 MPSTRLB03

131 Chapter 13. MPSTRLB

������������������������������� ����� ����������������������������������������������������������������������������������������������������������� �

��������������������� �

��������������������� �

���������������� �

��������������� �

������������������� �

��������� �������������� �

����� ����������������� �

����� ������� ���������� �

���������������������� �

Explanation: The summary for this execution of����fordevice�������at address������with volume serial number�����is printed.

� The number of passes executed and the number of recordsand tape marks processed is listed along with the totalnumber of compare, sequence, temporary, and permanentwrite errors.

� The total bytes transferred by write are also listed.

� If the��� ���parameter was specified, the number ofcontrol units detected (������) functions for writetemporary, erase gap, and write transient errors are listed.

� If���� ���is specified, these counts are zero (0).

� If�����is active, the counts for�����functions arelisted; otherwise they are zero (0).

Note: The information in the summary report marked with anasterisk is not always included in this message.

Solution: None required.

xxxxxxxx

MPSTRLB04 MPSTRLB07

132 MPST Messages and Codes Manual – Version 2.04

�������� ���� ��� ���������� �

Explanation: No test devices were configured for thisexecution of���.

Solution: Verify defined devices.

�������� ��������������� ��� ���� ���� ��������������

Explanation: The��������parameter specified a value of lessthan 28 or greater than the maximum size allowed. The�������parameter was changed to reflect the correct range for����.

� On MVS either��������or the device maximum is themaximum������allowed.

� On the PC������ is the maximum������allowed.

� On VM either��������or the device maximum is themaximum������allowed.

Solution: None required.

�������� ���� ��������

Explanation: An I/O error occurred during configuration.

This may occur when attempting to overwrite a tape using anon-expanded format device if the tape was previously writtenusing an expanded format device.

Solution: Initialize the tape with a tape mark using anon-expanded format device to correct the problem.

Warning: Initializing the tape with a tape mark will result in allexisting data on the tape being lost.STOP

MPSTRLB08 MPSTRLB08

133 Chapter 13. MPSTRLB

�������� ���� �������������������������������

Explanation: Device�������was not configured. ��������for not configuring:

� ������������������������������������—Thetest device is not defined as the correct DD card type.Correct the DD card type.

� �������������������������—DD card type6 specifies read-only operations. Correct DD card type.

� ������������������������ —The drive isassigned to another path.

� ����������—A test sequence with a write pass wasspecified but the cartridge is file protected. No testing canbe done on this device.

� ��������������������������—A��������for a20K I/O buffer failed. Increase the size of the region orpartition in which MPST is executing.

� ��������—An I/O error occurred during configuration.The error was described in message����������.

� ������������������—No device has beendefined for this DD name. Verify the device definition.

� ��������—An open for the device failed. Verify thedevice definition.

� �����������������������������������

������—The cartridge volume mounted on this devicecontains a valid OS tape label and is not file protected toprevent an inadvertent write. Testing cannot be done onthis device. With an OS tape label and file protection allwrite pass commands will be changed to table build passcommands.

MPSTRLB09 MPSTRLB12

134 MPST Messages and Codes Manual – Version 2.04

� �����������—The�������command has failed morethan 10 times on this device.

� ������������ ����������—The test device definitiondoes not define a cartridge device. Verify the devicedefinition.

Solution: Verify that the test devices are correctly defined,online, and available.

������ �� ��������������������� ������������ �����������!���� ���������

Explanation: � �����parameter detected but UUT���was notdefined. Volume serial number������will be ignored.

Solution: None required.

������ �� �������� ����#�������������"�������������

Explanation: If the block size specified by the�������parameter is less than 4098, the time to execute�����tocompletion may be very long.

Solution: None required.

������ �� ���������������������������������������

Explanation: The number of passes specified by the������

parameter has been completed for device�������at address�����with volume serial number�����. Testing hasterminated on that device but continues on other devices.

Solution: None required.

������ �� ����������������������������������������������

Explanation: ����has detected a������command entered atthe operator’s console. Testing on test device�������at address�����with volume serial number������has been stopped.

Solution: None required.

MPSTRLB13 MPSTRLB15

135 Chapter 13. MPSTRLB

��������� ������������������������������������������ ��������

Explanation: Testing on test device�����at address�����with volume serial number�������has been terminated due toa permanent error.

Solution: None required.

��������� ���������������������� ������� ��������������������������� ����������������������

Explanation: The��������parameter requested a larger blocksize than the device can handle. The block size has beenchanged to the correct������for this device.

� On MVS either��������or the device maximum is themaximum������allowed.

� On the PC������ is the maximum������allowed.

� On VM either��������or the device maximum is themaximum������allowed.

Solution: None required.

�������� ������������������������������������ ���������� ������������������� �

Explanation: The test device�����at address�����encountered an error in the segment number while performing awrite pass or a table build pass. The segment number wasneither equal to nor one greater than the previously retrievedsegment number.

Solution: None required.

MPSTRLB16 MPSTRLB17

136 MPST Messages and Codes Manual – Version 2.04

����� ��� �������� ���������� � �������������������������� ������������� ����� �������������

Explanation: The test device�����at address���� �had asequential locate performed on block identifier �������. Theblock identifier sought (�������) should be identical to theblock identifier read (�������). If these block identifiers arenot identical, the message���������is flagged with trailingasterisks (*).

The block identifier is 4 bytes long.

� The first byte is the segment number.

� The first two bits of the second byte identify the formatmode.

� The last six bits of the second byte and the third and fourthbytes are the logical block number.

Solution: None required.

����� ��� �������� �������� ��������������������������� ������������ ����� �������������

Explanation: The test device�����at address���� �had arandom locate performed on block identifier �������. Theblock identifier sought (�������) should be identical to theblock identifier read (�������). If these block identifiers arenot identical, the message���������is flagged with trailingasterisks (*).

The block identifier is 4 bytes long.

� The first byte is the segment number.

� The first two bits of the second byte identify the formatmode.

� The last six bits of the second byte and the third and fourthbytes are the logical block number.

Solution: None required.

MPSTRLB18 MPSTRLB19

137 Chapter 13. MPSTRLB

����� ��� ����������������������� ������� ������� ������������������� ���

Explanation: The test device�������at address�����encountered an error while building a block identifier using arandomly generated logical block number. The randomlygenerated logical block number did not fit within the boundariesof the Block ID Table and the table was corrupted.

The block identifier is 4 bytes long.

� The first byte is the segment number.

� The first two bits of the second byte identify the formatmode.

� The last six bits of the second byte and the third and fourthbytes are the logical block number.

Solution: Notify CS Software Support.

����� ��� ������������������������������������������������������������������������������������

�������������������������

Explanation: This message identifies the tape drive that iscreating the cartridge.

� The drive reading the cartridge is identified by ������,drive address ����� and �����.

� The drive creating the cartridge is identified by ������,drive address �����, control unit serial number �����,tape drive physical address ���������, and tape drivelogical address �������.

� The time is specified by hour:minute:second (��������)and the date is specified by month:day:year (����������).They identify when the write pass started.

� ����is the number of records per file.

If this device is a Model 3490E, the characters ’3490E’ willfollow����.

Solution: None required.

MPSTRLB20 MPSTRLB21

138 MPST Messages and Codes Manual – Version 2.04

����� ��� ����������������� ����� ���������� �������������� ��� ���������� �����������

Explanation: The test device�������at address�����encountered an error while performing a block identifier readduring a write pass or a table build pass. Either the logical blocknumber or the segment number was out of sequence. The������ ������������������field (� ����) remainsthe same on subsequent messages until a proper sequence isreestablished.

The block identifier is 4 bytes long.

� The first byte is the segment number.

� The first two bits of the second byte identify the formatmode.

� The last six bits of the second byte and the third and fourthbytes are the logical block number.

The format mode bits are not used in the calculations made todetermine if the block identifier is in error.

Solution: None required.

����� ��� �����������������������������������������������������������

Explanation: Incorrect status was received for an I/O operationto device�������at address������during a������pass. Theactual status received was������and the command executed was���.

Solution: None required.

MPSTRLB22 MPSTRLB23

139 Chapter 13. MPSTRLB

����� ��� �������� ����������� ������ ������� ��������������������� �

Explanation: The test device������at address���� encountered a logical block number of zero in the last entry ofthe Block ID Table during a random locate pass.

The table entry is 8 bytes long.

� The first byte is the segment number.

� The first two bits of the second byte identify the formatmode.

� The last six bits of the second byte and the third and fourthbytes are the logical block number.

� The fifth byte is reserved and always contains zeros.

� The sixth, seventh, and eighth bytes are the highest logicalblock number of the segment.

Solution: None required.

����� ��� �������� �� �����������������

Explanation: For each block identifier read during a write passor a table build pass both the test device������and the addressare identified, and the block identifier number read is listed.

The�������������field (������) is 4 bytes long.

� The first byte is the segment number.

� The first two bits of the second byte identify the formatmode.

� The last six bits of the second byte and the third and fourthbytes are the logical block number.

Solution: To stop message���������� from being issued, enterthe� ��������parameter.

MPSTRLB24 MPSTRLB26

140 MPST Messages and Codes Manual – Version 2.04

�������� ���������������������������������������������

Explanation: The test device���at address�����completed a write pass or a table build pass. The last blockidentifier (������) resulting from this pass is entered into theBlock ID Table.

If the write pass or the table build pass was successful, this������ number should match the block identifier in message��������.

Note: If the completed table build pass was performed on a tapepreviously created by a write pass, the��������number is oneless than the block identifier number displayed in the messageaccompanying the initial write pass.

The block identifier is 4 bytes long.

� The first byte is the segment number.

� The first two bits of the second byte identify the formatmode.

� The last six bits of the second byte and the third and fourthbytes are the logical block number.

Solution: None required.

�������� ��������������������������� ����������������

Explanation: The test device���at address�����encountered a block identifier of zero when a Read Block IDwas performed.

Solution: None required.

�������� ������������������������������� ����������������

Explanation: The test device���at address�����completed a write pass or a table build pass. ��������was thelast block identifier retrieved from the tape.

Solution: None required.

xxxxxxxx

MPSTRLB28 MPSTRLB41

141 Chapter 13. MPSTRLB

�������� �������������� ��� ������������ �������" �� �����������$������� �� ���

Explanation: The test device������encountered a deferredunit check during a table build pass. The first four bytes(�� ���) of the channel status word (CSW) and the first foursense bytes (�� ���) are displayed

Solution: None required.

��������� ���������������� ����������������#�������������������

Explanation: The Block ID Table was filled during a write passor a table build pass and the pass was terminated. Subsequentpasses are executed using the entries in the table which may notinclude all the Block ID’s on the tape.

Solution: None required.

�������� ������������������ ����$�����"����������$����"���������������"������������������"�������

��������$�����������������������������������������

� ����������"���� �����"������������ ����������� ���� �����"��������������

� �����"�������� ���� ��������"����$����� �������!�"����$����"���$����������������� ��������"���������� �������!�"���������� ����������#�������

MPSTRLB42 MPSTRLB42

142 MPST Messages and Codes Manual – Version 2.04

���������������������������������

�������������������������� �

������������������� �

������������������� �

��������������� �

�������������� �

������������������ �

��������������������� � �

�������������������� �

������������������������ �

��������������������� �

Explanation: A write pass has been completed for device������at address������with volume serial number�����.The summary report for the write pass is contained within thismessage.

If������is active, the counts for������functions are listed;otherwise, they are zero.

Note: The information in the summary report marked with anasterisk is not always included in this message.

Solution: None required.

��������� ����������������������� ������������������������������

Explanation: The summary information for all passes for testdevice�������and tape volume serial number������is notbeing kept.

Solution: None required.

xxxxxxxx

MPSTRLB50 MPSTRLB50

143 Chapter 13. MPSTRLB

�������� �������� ����� ���������������������������� ��������������������������� ������������������������������������������������������������

Explanation: A temporary error was detected and the controlunit is in forced logging mode on test device������at address��� �with volume serial number����� �mounted.

� ����� ��—The record number of the record on whichthe error occurred.

� ���������—The number of bytes transferred at thetime of the error.

� ���������—The number of times the operation hasbeen retried.

� ������—The channel command being executed.

� ���������—The SIO condition code.

� �������������—The unit and channel status for CSW.

� ������—The CPU ID of the CPU on which the erroroccurred.

� ���������—The actual channel path on which the erroroccurred.

� � �������—The sense bytes.

Solution: None required.

MPSTRLB51 MPSTRLB51

144 MPST Messages and Codes Manual – Version 2.04

��������� ������������ ����������������������������������������������

���� ������������ ������ ��������������������������� ���������������������������������� ��������

Explanation: A temporary error has occurred on test device������at address������with volume serial number�� ����at�������� on ����������.

� �������—The record number of the record on whichthe error occurred.

� ���������—The number of bytes transferred at thetime of the error.

� � �� �����—The number of times the operation hasbeen retried.

� ������—The channel command being executed.

� �������� ��—The SIO condition code.

� �������������—The unit and channel status for CSW.

� �����—The CPU ID of the CPU on which the erroroccurred.

� ���������—The actual channel path on which the erroroccurred.

� ����������—The sense bytes.

Solution: None required.

MPSTRLB52 MPSTRLB52

145 Chapter 13. MPSTRLB

�������� ������������ ���������� �������������������������������������������

������������������������������������� ��������������� �������������������������������������������

Explanation: Either a permanent or a degraded error hasoccurred on test device�������at address������with volumeserial number�� ����at �������� on ����������.

� �������—The record number of the record on whichthe error occurred.

� ���������—The number of bytes transferred at thetime of the error.

� � �� �����—The number of times the operation hasbeen retried.

� ������—The channel command being executed.

� �������� ��—The SIO condition code.

� �������������—The unit and channel status for CSW.

� �����—The CPU ID of the CPU on which the erroroccurred.

� ���������—The actual channel path on which the erroroccurred.

� ����������—The sense bytes.

Solution: None required.

MPSTRLB54 MPSTRLB57

146 MPST Messages and Codes Manual – Version 2.04

�������� ������������ ������������� ������������������������������������ �������������������������������

Explanation: The�������������command issued to device����at address������with volume serial number�� ���failed.

Solution: None required.

�������� ������������ ��������������������������������������� �������������

Explanation: An error occurred on device�����at address�����with volume serial number�� ���. The error recoveryprocedure action (ERPA) code of����is unsupported.

Solution: Gather the sense data and notify CS SoftwareSupport.

�������� ������������ �������� ������������� �����������������������

Explanation: The buffered log overflowed for device�����ataddress������with volume serial number�� ���. The logcounters have been added to the statistics. This message willspecify when the overflow was caused by a dismount.

Solution: None required.

�������� ������������ �������� ��������������������������� ����������������

Explanation: The buffered log data is read at the end of eachpass for device�����at address������with volume serialnumber�� ���. The log counters have been added to thestatistics.

Solution: None required.

MPSTRLB58 MPSTRLB61

147 Chapter 13. MPSTRLB

�������� ������������������������������������ � ��������� �����������������������

Explanation: A read buffered log CCW was issued to obtainthe current buffered log for device������at address������withvolume serial number������. The CCW failed with an SIOcondition code of�����and���of�� � ��.

Solution: None required.

������� �������������������������������������������"�������������� ��

Explanation: A unit check was posted due to end of data beingdetected on the cartridge tape. This is an excepted error.

Solution: None required.

��������� ������������������������� �����������������"��������!������

Explanation: The control until detected an incorrect blockidentifier sequence on test device������at address������withvolume serial number�������mounted. An error recoveryprocedure action (ERPA) code of X’41’ is returned.

Solution: None required.

��������� ������������������������ ��������������� ���������

Explanation: A pass has been started on test device������ataddress������with volume serial number������. The type ofpass ( ��) is����for a table build pass,����for a sequentialread block identifier pass,�����for a random locate pass, or���

for a write pass.

Solution: None required.

MPSTRLB62 MPSTRLB64

148 MPST Messages and Codes Manual – Version 2.04

��������� ������������ ���������������� ����� �������������

Explanation: A pass has ended on test device� ���ataddress������with volume serial number��� ��. The type ofpass (����) is�����for a table build pass,����for a sequentialread block identifier pass,����for a random locate pass, or���

for a write pass.

Solution: None required.

�������� ������������ ������������� ��� ���������!��� �� ��������������������������� �� ��������������

Explanation: This message always follows message��������.

Solution: None required.

�������� ������������������ ����������������� �������!������������� � ��������� ���������� ������ �

Explanation: A cartridge tape written in 3480–2 XF format ismounted on device� ���at address������and the device doesnot support 3480–2 XF format.

Solution: None required.

MPSTRLB65 MPSTRLB91

149 Chapter 13. MPSTRLB

� ������ ��������� ����������� �

Explanation: If the������parameter was specified, thismessage is displayed at the conclusion of a write pass or a tablebuild pass. Each message contains two eight byte table entries.Message���������is repeated until all table entries have beenlisted.

The table entry is 8 bytes long.

� The first byte is the segment number.

� The first two bits of the second byte identify the formatmode.

� The last six bits of the second byte and the third and fourthbytes are the logical block number.

� The fifth byte is reserved and always contains zeros.

� The first two bits of the sixth byte identify the formatmode.

� The last six bits of the sixth byte and the seventh andeighth bytes are the logical block number for the last blockof this segment.

Solution: None required.

� ������ �����������������

Explanation: The parameter (���) is either coded incorrectlyor is invalid for the� ������command for the�����function.

Solution: Re-enter the� ������command using the correctparameter.

MPSTRLB96 MPSTRLB98

150 MPST Messages and Codes Manual – Version 2.04

��������� ��� ��� �����������������

Explanation: The� ������command�������was issued to���. The valid� ������commands for�����follow thismessage.

Solution: None required.

��������� ���������������������� ��������������

Explanation: The� ����������������is not supported by the����function.

Solution: None required.

��������� ��������������

Explanation: This message is issued in response to a� �����

����������command requesting the current value of���������.

Solution: None required.

151 Chapter 14. MPSTTIP

Chapter 14. MPSTTIP

Tape Independent Protocol Set (TIPS) Messages

All MPST functions and diagnostics use standard I/O operationchecking routines and these routines issue standard messages forerrors. Error message numbers are issued according to whichfunction or diagnostic was being run when the error occurred.

Hint: To make finding the messages easier, both the messagenumber and the message text are bold.

The following messages are issued for Tape IndependentProtocol Set:

MPSTTIP00 MPSTTIP06

152 MPST Messages and Codes Manual – Version 2.04

��������� ������ ���� ����������������

Explanation: The������function is executing.

Solution: None required.

��������� ��������������������

Explanation: The parameter (����) is either coded incorrectlyor is invalid for the������function.

Solution: Enter the correct parameter.

��������� ��������������������

Explanation: Device������is starting.

Solution: None required.

��������� �������� ������� �����

Explanation: A������command was entered; but no devicesare currently defined.

Solution: Define devices.

��������� ��������������� ���

Explanation: ������is ending operation with the specifieddevice.

Solution: None required.

�������� ����������������� ����������� � ����� �����

Explanation: Up to 128 devices can be defined at one time.

Solution: Define fewer drives.

MPSTTIP07 MPSTTIP20

153 Chapter 14. MPSTTIP

��������� ���� ������� ������������������

Explanation: Command�����failed on device������.

Solution: Correct the problem and reissue the command.

��������� ���� ���������� �������������

Explanation: Device�������at address������failed. ������specifies why it failed.

Solution: Correct the problem and reissue the command.

��������� ���������� ������������� �� � �

Explanation: Only 29 commands are allowed per�����

operation.

Solution: Delete commands from this operation of�����.

��������� ���������������� ������� ���

Explanation: A 15 second timeout has occurred.

Solution: Retry device.

��������� ���� ��������� ������ ���

Explanation: Dynamic device definition has failed on drive����.

Solution: Check availability of device and retry.

��������� �� ���� � �� ������������� ��������������

Explanation: Summary information for the������operationfollows this message header.

Solution: None required.

MPSTTIP21 MPSTTIP84

154 MPST Messages and Codes Manual – Version 2.04

��������� ���� ���������������������������� � ����� ����

��������� � ����� �

Explanation: This message lists the������commands thatcompleted or failed for each test device.

Solution: None required.

��������� �������� ��������� ����

Explanation: The������command did not receive a correct�����key reply.

Solution: Verify that the device is������capable.

��������� � ���� ��������� ��� ������ ��� �

Explanation: �����was unable to allocate the requesteddevice.

Solution: Verify that the device is accessible.

��������� ������������� ����� � ��������������� ��� �����

Explanation: An error occurred on device������while�����was executing.

Solution: Enter���(ignore this device),���(retry this device), or��(cancel operation).

�������� ��������������

Explanation: An error occurred while trying to save thetransferring file.

Solution: Check the JCL or the data set name.

MPSTTIP85 MPSTTIP96

155 Chapter 14. MPSTTIP

��������� ����������� ���������������

Explanation: The size transferred did not match the size in thetape header. This is probably a bad tape.

Solution: None required.

��������� ����������� �������

Explanation: Size mismatch or no dump is available.

Solution: Issue a��������command and verify availability.Then, reissue the���������command.

��������� ��������������

Explanation: The file specified by the������command couldnot be accessed.

Solution: Check the file name, data set name, or JCL.

��������� ��������������������������

Explanation: The file specified by the������command couldnot be accessed.

Solution: Check the file name, data set name, or JCL.

��������� �����������������������������

Explanation: The����������������is not supported by the�����function.

Solution: None required.

MPSTTIP97 MPSTTIP99

156 MPST Messages and Codes Manual – Version 2.04

��������� ����������������������������������������������� ����� ������������ ����������� ������������� ������������� ������� �

Explanation: This message is issued in response to a����

command.

Solution: None required.

��������� ����������������������������� ����������� �������� �������� ������������ � ������������ ������������� �������� �� ������ �������� �

Explanation: This message is issued in response to a������

command.

Solution: None required.

��������� ������������������������

Explanation: This message lists the������commands thatcompleted or failed for the test device.

Solution: None required.

157 Chapter 15. MPSTTKD

Chapter 15. MPSTTKD

Track Dump (TRKDUMP) Messages

All MPST functions and diagnostics use standard I/O operationchecking routines and these routines issue standard messages forerrors. Error message numbers are issued according to whichfunction or diagnostic was being run when the error occurred.

Hint: To make finding the messages easier, both the messagenumber and the message text are bold.

The following messages are issued for Track Dump:

MPSTTKD00 MPSTTKD04

158 MPST Messages and Codes Manual – Version 2.04

��������� ���������������������������������������������������������!�������"���������������������������#

Explanation: The� ������function is executed on device�����with volume�������on a�����device.

Solution: None required.

��������� ���������������� ������������

Explanation: A��� ���macro for an I/O buffer has failed.

Solution: Increase the size of the memory for MPST and rerunthe job.

��������� ��������������������������������������

Explanation: An open for the test device failed or the testdevice is not a DASD device.

Solution: Verify that the first test device DD card is codedcorrectly.

��������� �!�������������������������������������

Explanation: The cylinder or head number specified by the �����parameter is not valid for the current test device.

Solution: Enter the correct cylinder or head number.

�������� ����������������������������������� �������

Explanation: The home address (HA) or record zero (R0)record could not be read, or the number of permanent errorsreading data records exceeded the number specified by the���� �parameter. Dumping of that track terminates anddumping of the next track (if specified) begins.

Solution: None required.

MPSTTKD05 MPSTTKD09

159 Chapter 15. MPSTTKD

��������� ��� ����� ��� ������������������� ���� ����

Explanation: A permanent error occurred dumping a datarecord. Any data that could be read is printed. Dumping of thatrecord terminates and dumping of the next record begins.

Solution: None required.

��������� �� ��������������� �������� �����

Explanation: A permanent error occurred reading a data record.Any data that could be read is printed but may not be the exactdata that was in the record.

Solution: None required.

��������� �� �������������������� � �� �

Explanation: A�� ���command was accepted by the������

function.

Solution: None required.

��������� ��������� ��� �� �� ��� ����������� �� �� ������� ����� �

Explanation: The�������parameter requested is greater thanthe number of tracks remaining on the SA cylinder.

Solution: Reduce the number of tracks requested.

��������� ������� �� ��� �� �� ��� ����������� �� �� ������� ����� �

Explanation: The�������parameter requested is greater thanthe number of tracks remaining on the CE cylinder.

Solution: Reduce the number of tracks to dump.

MPSTTKD10 MPSTTKD14

160 MPST Messages and Codes Manual – Version 2.04

��������� ��� � �� �����������

Explanation: The parameter (����) is either coded incorrectlyor is invalid for the���������function.

Solution: Enter the correct parameter.

��������� ���� �������

Explanation: An error occurred while attempting to read thehome address (HA) record.

Solution: None required.

��������� ���� ������� ������ ����������� ���

Explanation: An error occurred while attempting to read recordzero (R0).

Solution: None required.

��������� ���� ������� ��������� ������� ��������������������

������ ��������������

Explanation: An error occurred while attempting to read orsearch for a data record.

Solution: None required.

�������� ���� �������

Explanation: An error occurred while executing a sense (04)command on initial startup.

Solution: None required.

MPSTTKD15 MPSTTKD19

161 Chapter 15. MPSTTKD

������ �� ������������

Explanation: An error occurred while attempting to read thecount field of a data record.

Solution: None required.

������ �� ����������� ��������������

Explanation: The dump which follows is a space count dumpof the track.

Solution: None required.

������ �� ��� ����������� ������������������

Explanation: A space count dump was requested but no datawas transferred by the space count CCW chain.

Solution: None required.

������ �� ������������������������� �����

Explanation: An error occurred while executing a space count(0F) and read data (06) command chain.

Solution: None required.

������ � �� ���������������� ������������������������� ���� ���� ����

Explanation: The�������parameter requested is greater thanthe number of tracks remaining on the volume. Tracks aredumped until end of volume is reach. Then,������

terminates with return code 4

Solution: Reduce the number of tracks requested.

MPSTTKD20 MPSTTKD24

162 MPST Messages and Codes Manual – Version 2.04

�������� ������������������� �� ���� ������� ��������

Explanation: A read device characteristics command failedwhile trying to initialize the device.

Solution: Retry��������. If the problem persists, printeroutput should be retained and given to CS Software Support.

�������� ������������ ���������������������������� �����

Explanation: This is the start of the dump of a track. ������is the track address in hexadecimal and in decimal.

Solution: None required.

������� ���������� ���������������������������� �����

Explanation: This is the end of the dump of a track. �������isthe track address in hexadecimal and in decimal.

Solution: None required.

������� �� �������������������������������������� �����

Explanation: This is the dump of a record on a track. The�����������is the record address in hexadecimal and indecimal.

Solution: None required.

�������� �������������� ������������������ ������������������

Explanation: The track to be dumped is a defective alternatetrack. Dumping of that track terminates and dumping of thenext track (if specified) begins.

Solution: None required.

MPSTTKD25 MPSTTKD28

163 Chapter 15. MPSTTKD

��������� ���������� � ���� ��������������� ����� �������� ��� ���

Explanation: The track to be dumped is a defective track. Thealternate track assigned to this track will be dumped.

Solution: None required.

��������� ����������������� ���� ��� �������������������

Explanation: The track to be dumped is an unassignedalternate track. Dumping of that track terminates and dumpingof the next track (if specified) begins.

Solution: None required.

��������� ��������������� ���� ��� �����������������

Explanation: The track to be dumped is an assigned alternatetrack. The dump of that track follows this message.

Solution: None required.

��������� ����������� ������������������������� ���������������������� ������������������������������������������������������������

Explanation: The table printed is a summary of the records onthe track being dumped. The cylinder (����), head (���� and��), record number (�� and ���), key field length (�� and ���),and data field length (���� and �����) for each record on thetrack is listed in hexadecimal and decimal.

Solution: None required.

MPSTTKD29 MPSTTKD33

164 MPST Messages and Codes Manual – Version 2.04

��������� ��������������������

Explanation: The device for�������has no valid CE or SAcylinders.

Solution: None required.

��������� ������������������ ���

Explanation: The������parameter was not specified and the������function terminates. ��������.�� is a requiredparameter for������.

Solution: Correct the�������control card.

��������� ����� � ���������

Explanation: The record dump was an end-of-file record.

Solution: None required.

��������� ��������� �������� ���������

Explanation: The record dumped was part of an overflowrecord.

Solution: None required.

��������� �����������������������������������������������������

Explanation: The number of bytes used on this track up to andincluding this record, but not including home address (HA) andrecord zero (R0), is����.

Solution: None required.

MPSTTKD34 MPSTTKD44

165 Chapter 15. MPSTTKD

������ � ����������������� � �������������������� ����������������� ������� ���

Explanation: The number of bytes read for this track exceedthe track capability of the device.

Solution: None required.

������ � �� ������������

Explanation: The data that follows is the data from the homeaddress (HA) record. The five bytes dumped are the flag byte,the cylinder address (two bytes), and the head address (2 bytes).

Solution: None required.

������ � ���������� ��������������

Explanation: The data that follows is the data from the countfield for the record. The eight bytes dumped are the cylinderaddress (two bytes), the head address (two bytes), the recordnumber (one byte), the key field length (one byte), and the datafield length (two bytes).

Solution: None required.

������ � �������� ���

Explanation: The data that follows is the data from the keyfield for the record.

Solution: None required.

������ ������ ���

Explanation: The data that follows is the data from the datafield for the record.

Solution: None required.

MPSTTKD51 MPSTTKD54

166 MPST Messages and Codes Manual – Version 2.04

�������� ����������� �� ������� ����

Explanation: No data was transferred when the record wasread.

Solution: None required.

�������� �������� ��������������� � ���

Explanation: Less than eight bytes were transferred when therecord was read. The complete count field was not transferredand the length of the key and data fields is unknown. Thesefields will not be dumped.

Solution: None required.

�������� � ������������� ��������������� �� �

Explanation: Exactly eight bytes were transferred when therecord was read (only the count field) but the count fieldindicated that the data field length was greater than zero (not anend of file record).

Solution: None required.

�������� ������� ���� �����

Explanation: The key field length in the count field was greaterthan zero but less than the number of bytes transferred when therecord was read. A dump of the partial key field follows thismessage.

Solution: None required.

MPSTTKD55 MPSTTKD60

167 Chapter 15. MPSTTKD

��������� ������������� ����

Explanation: The data field length in the count field wasgreater than zero but less than the number of bytes transferredwhen the record was read. A dump of the partial data fieldfollows this message.

Solution: None required.

��������� ��������������������� �����

Explanation: When the record was read, more data bytes weretransferred than the total for the key and data field as indicatedin the count field. The extra data bytes follow this message.

Solution: None required.

��������� ��������� ���������������������������������������������

Explanation: A correctable data check occurred while thisrecord was being read. The uncorrected data is printed for therecord.

Solution: The data at offset ���� is in error and should becorrected to ����.

��������� ��������������������������� �����������������

Explanation: The record����, requested in the�������option,was not found on the specified track.

Solution: Specify���������������to obtain a summary of therecords on this track.

MPSTTKD91 MPSTTKD96

168 MPST Messages and Codes Manual – Version 2.04

��������� ��� � �� �����������

Explanation: The parameter (����) is either coded incorrectlyor invalid for the��������command for the� �����function.

Solution: There are no��������command parameters for ����.

��������� � ��� ������ ��� �

Explanation: The�������������parameter was specified, butthe device is not defined.

Solution: If the first device defined in the device definition isnot the device to be used, specify the correct address or DDname in the parameter.

��������� � ��� �������������

Explanation: The�������������parameter specified does nothave a path available.

Solution: Select another device.

��������� � ��� ����� �

Explanation: The�������������parameter specified is notenabled.

Solution: Enable the device and try again.

��������� �������������������������������

Explanation: The��������command������ �was issued to ����. There are no��������command parameters for ����.

Solution: None required.

MPSTTKD97 MPSTTKD97

169 Chapter 15. MPSTTKD

������ ���� ������������ ���������������������

Explanation: The���� �����������is not supported by the��������function.

Solution: None required.

170 MPST Messages and Codes Manual – Version 2.04

171 Chapter 16. MPSTTMC

Chapter 16. MPSTTMC

Tape Monitor and Control (TMC) Messages

All MPST functions and diagnostics use standard I/O operationchecking routines and these routines issue standard messages forerrors. Error message numbers are issued according to whichfunction or diagnostic was being run when the error occurred.

Hint: To make finding the messages easier, both the messagenumber and the message text are bold.

The following messages are issued for Tape Monitor andControl:

MPSTTMC00 MPSTTMC04

172 MPST Messages and Codes Manual – Version 2.04

��������� �����������������������������������������������������"���������������������������"����������� �������������������������������������� ������������������������#�������������������� ���������������������������������������"����������� �������������������������������������������������"�������������������������

Explanation: The�����function is executing.

Solution: None required.

�������� ����������������������

Explanation: The parameter (����) is either coded incorrectlyor is invalid for the�����function.

Solution: Enter the command using the correct parameter.

�������� ��!������������ �����������������������������������������������������

Explanation: The�����status for all defined drives is listed.

Solution: None required.

��������� ���������!������������

Explanation: A�����command was entered; but no devices arecurrently defined.

Solution: Define devices.

��������� ��������������������#��������

Explanation: ����is waiting for another������command tobe entered.

Solution: You can enter a������command now.

MPSTTMC05 MPSTTMC09

173 Chapter 16. MPSTTMC

��������� ��� ����������

Explanation: The���������parameter was entered and������� is the trace point position.

Solution: None required.

��������� ���������� ��������� �� �� � ������� ���

Explanation: Too many devices are being defined.

Solution: The maximum number of device definitions is 8.

��������� ���� ������� ������������������������������

Explanation: Device�������encountered an error on the�����

command.

Solution: None required.

��������� ���� ���������� ������������ ������������� ��������

Explanation: Device�������at address�����failed toconfigure. ���������specifies why it failed.

Solution: Correct the problem and reissue the command.

��������� ���������� ���������������������� �� � �

Explanation: Too many commands were entered at one time.

Solution: Enter fewer commands.

MPSTTMC10 MPSTTMC13

174 MPST Messages and Codes Manual – Version 2.04

��������� ������������������������������������������������������������� ������������ ���������� �� ������������������� ������������ ���������� �� �������������������������������������������������

Explanation: ����has terminated and devices�����were leftwith forced logging enabled.

Solution: Disable force logging mode.

��������� ��������������� ������� ���

Explanation: The timer was set to a value other than zero andhas timed out.

Solution: None required.

��������� � ��� ������

Explanation: ����called the�������function and the calltype failed. �������describes the failure.

Solution: Correct the problem described in the failure �����.

��������� � ��� ������������� ��� ������������ �� �������������

Explanation: An attempt was made to request a������������

for device����, prior to that device being defined to����.

Solution: � �� ��device and reissue the command.

MPSTTMC14 MPSTTMC95

175 Chapter 16. MPSTTMC

�������� �������������������! ������������������������������������������������������������������������� ���� �������������������������� "���������� ��������������������������������������������� �����!�������������������������������������������������������������������������������������! ������������������������

Explanation: The message is sent in response to the timervalue being set to zero.

Solution: None required.

��������� ��� �������� ��������������

Explanation: Dynamic device definition has failed on drive����.

Solution: Check availability of device and retry.

��������� � � ������������������

Explanation: Parameter (����) is either coded incorrectly or isinvalid for the�����function.

Solution: Enter the command using the correct parameter.

�������� ����������������������������� ����������

Explanation: When entering the ����� command,������must be entered before any other commands.

Solution: Correct the problem.

� If�������was entered as a run-time command, using��� , re-enter the commands with�������entered first.

� If�������was entered in an incorrect position in a controlstatement,�����function ends. Correct the control cardand restart����.

MPSTTMC96 MPSTTMC99

176 MPST Messages and Codes Manual – Version 2.04

��������� �� �����������������������

Explanation: The���� �command���������was issued to���. The valid���� �commands for�����follow thismessage.

Solution: None required.

��������� �����������������������������������

Explanation: The���� ���������� is not supported by the����function.

Solution: None required.

��������� ��������������

Explanation: This message is issued in response to a����

���������command requesting the current value of��������.

Solution: None required.

��������� ����������������

Explanation: This is an informational message.

Solution: None required.

177 Chapter 17. MPSTTSC

Chapter 17. MPSTTSC

Tape Scan Messages

All MPST functions and diagnostics use standard I/O operationchecking routines and these routines issue standard messages forerrors. Error message numbers are issued according to whichfunction or diagnostic was being run when the error occurred.

Hint: To make finding the messages easier, both the messagenumber and the message text are bold.

The following messages are issued for Tape Scan:

MPSTTSC00 MPSTTSC05

178 MPST Messages and Codes Manual – Version 2.04

������ �� ����� ��������� ��������������������������������� ����������

Explanation: The����������function is executed on device�����with volume�������on a�����device.

Solution: None required.

������ �� ����������������������

Explanation: The parameter (����) is either coded incorrectlyor is invalid for the����������function.

Solution: Correct the error and restart���������.

������ �� ������ �������������

Explanation: A sense command failed to completesuccessfully.

Solution: None required.

������ �� �������������� ��������

Explanation: ���������has detected a tape mark condition.

Solution: None required.

������ � ���� ����������������������������

Explanation: The only device types supported for���������

are 3480 and 3490.

Solution: None required.

������ � ��������� ����������������

Explanation: An open for the test device failed.

Solution: Verify that the first test device DD card is codedcorrectly.

MPSTTSC06 MPSTTSC10

179 Chapter 17. MPSTTSC

��������� ����������� �������������� �������������������������������� ���� ����������������

Explanation: An error has occurred while trying to read thefirst record on the tape. ����������is unable to determine thelabel type. No additional processing of this tape will occur.

Solution: None required.

�������� ���������������������������������� ������������������������

Explanation: The number of physical blocks counted withinthe data file does not compare to the block count written in thetrailer record. This message applies to standard label (SL) tapesonly.

Solution: None required.

�������� ������������ �������������� ���������������������� �������

Explanation: An I/O error has occurred while trying to read alabel during a label dump.

Solution: None required.

��������� ��������������������������������

Explanation: A����command was accepted by the���������function and����������terminates.

Solution: None required.

��������� ��������� ������������������������������������������

Explanation: A permanent error was detected causing���������to terminate.

Solution: Determine the cause of the permanent error andrestart���������.

MPSTTSC11 MPSTTSC14

180 MPST Messages and Codes Manual – Version 2.04

��������� ������ ����� ������������������������������������������������ �����������������������

Explanation: The file ID and the data set name in ����

contains all zeroes. This is usually the result of a program (suchas ����) that rewrites header labels. An all-zero file ID is adummy HDR1 record.

The last operations to the tape were label rewrites.

Solution: None required.

��������� �������������������� �������������������

Explanation: The����������label dump function has started.

Solution: None required

��������� ��������������������������������������� ����� ��� ������������������ ���������������

Explanation: The file ID (data set name) in HDR1 does notcompare to the next�� ���� ��’s file ID.

This condition indicates that this tape was not closed outproperly when it was last used as an output tape. The trailerrecords are old and not associated with the HDR1�records.

Solution: Check the system or console log for any unusualconditions that may have occurred while this tape was beingcreated (such as��������� ����������or a���������).

�������� ���������������� ���������������� ����������������������������������� ����

Explanation: The label dump will continue after skipping theerror record.

Solution: None required.

MPSTTSC15 MPSTTSC18

181 Chapter 17. MPSTTSC

��������� ��!������������������

Explanation: The rewind command has failed.

Solution: None required.

�������� ������������������������ ���������������������� ��������������������������� ���� "����������

Explanation: The tape has either two tape marks in a row orhas a tape mark followed by a trailer label at the beginning ofthe tape.

This may indicate that while this tape was being created an����� occurred, ���������������������was received, andthe operator made the volume�������at load point to satisfy theintervention. (The operator should have used a “dummy” tape tosatisfy any intervention.)

Solution: This volume requires re-initialization before it can beused as an SL tape.

�������� ������������������������������ �������������

Explanation: ��� ����did not detect any problems whileperforming this function.

Solution: None required.

��������� ���������������������������������������������������������$��������#������������������� ������������ ��������

Explanation: An error occurred while���� ����wasattempting to read the first record on the tape.

Solution: Re-initialization or a tape mark may be requiredbefore the volume can be reused.

MPSTTSC19 MPSTTSC22

182 MPST Messages and Codes Manual – Version 2.04

��������� �� ������������������� ������� ������ �������������� ��� �����

Explanation: This message indicates that data records arebeing skipped (via FSB commands) in order to get to the nexttape mark where the trailer records should reside.

If the tape is not closed out and an old tape mark is not present,unpredictable results can occur after this point.

Solution: None required.

��������� ��������� ��� ���������������� ����������� ���������������������� ����� �����������������

Explanation: The tape was read immediately after detection ofa tape mark and the last tape mark was probably the last validrecord written. This error is caused by “old data” being read.

Solution: None required.

��������� ������ ������ � � ������ ���� ������ ����� � �� �

Explanation: A read CCW with a byte count of 80 and no SLIwas executed and resulted in an�������� ����� ��indicatorbeing set. A record other than 80 bytes in length was read whena label record was expected.

Solution: None required.

��������� �� �������� � ���� ������� � ���������������� ������������ ������ ����������� ������ �� ����� �

Explanation: The volume being read starts with two tapemarks. � �������will only process NL tapes until two tapemarks are detected. Testing on this tape terminates.

Solution: None required.

MPSTTSC23 MPSTTSC28

183 Chapter 17. MPSTTSC

��������� ���������������������������������������

Explanation: The failing record�������is reported for file����.

Solution: None required.

��������� ���������������������� ����������������� ���

Explanation: An 80 byte record with VOL1 as the first fourbytes was detected as the first record at load point.

Solution: None required.

�������� ���������������������� ���������

Explanation: If ���������is�������������, a tape markwas the first record detected at load point.

If ���������is� � (non-standard label), the tape is determinedto have a non-standard label.

Solution: None required.

�������� �� ������ ������������������� �������������������������������������"�������

Explanation: ������and�������will only be executedagainst SL (standard label) tapes.

Solution: None required.

��������� ����������������������������������!��������� �������������������� ������"������������������

Explanation: The next record following the error record wasnot in sequence indicating “old data” was read. The label dumpwill try to continue after skipping the error record.

Solution: None required.

MPSTTSC29 MPSTTSC33

184 MPST Messages and Codes Manual – Version 2.04

�������� ���������� ��������������������������������"������������� ��

Explanation: The back space block command failed duringprogram error recovery of a label record.

Solution: None required.

�������� ��������� ������������������������������������������ ����������������

Explanation: No error was detected while reading the recordswithin file�����.

Solution: None required.

�������� ������������������������������� ���������������"� ���������������� ����������� ������"������ ��� ���

Explanation: Since no data was transferred on the read-forwardcommand, the record may have a partial beginning. ���������

will attempt a read-backward command at this point.

Solution: None required.

�������� ��������� �����������������������������������������!����������������������

Explanation: ���������has positioned the tape for visualexamination after a data check.

Solution: Visually examine the tape for damage.

������� ��������������������������������

Explanation: The first 80 bytes of data for file�����, record������follow this message.

Solution: None required.

MPSTTSC34 MPSTTSC37

185 Chapter 17. MPSTTSC

������ �� ����������� �����������!����������������������������� �������

Explanation: A forward space file (FSF) command failed whilethe program was trying to position the tape to the next set oflabels.

Solution: None required.

������ �� �����������!�������������������������������������������� ������������������

Explanation: A minimum of one byte and up to a maximum of80 bytes of data transferred forward. The error record followsthis message.

Solution: None required.

������ �� ��������������������� ��������������������� ��������

Explanation: ���������has successfully skipped over theerror record.

Solution: None required.

������ � ����� �����������������������������������������������������������������������"����������������

Explanation: ���������has determined that the program hadread into “old data”.

This may indicate that when the new data set was created it didnot complete properly and data, from a prior write operation,was left on the tape. The tape is not closed out.

Solution: None required.

MPSTTSC38 MPSTTSC40

186 MPST Messages and Codes Manual – Version 2.04

�������� ������������������������������������������������������������������������������������������

Explanation: The volume under test did not complete normallywhen it was last used as an output tape.

This may indicate that while this tape was being created asystem problem occurred and the CPU needed to be IPL’d.

Solution: Check the system and console logs for unusualconditions such as: �����, re-IPL of CPU, or interventions.

�������� �������������������������� ������������������������ ����� �����

Explanation: The tape appears to���������to havecompleted properly when created, but the tape now has a readerror.

Solution: Check the tape for damage.

� If the tape is damaged, check the last two devices that usedthe tape.

� If the tape is not damaged, check the device used to createthe tape.

Note: If the tape stick is visible, replace the volume.

�������� ���� �������������������������� � �����������

Explanation: The analysis of the first error follows thismessage.

Solution: None required.

xxxxxxxx

MPSTTSC41 MPSTTSC44

187 Chapter 17. MPSTTSC

��������� ���� ���� �� ������ ����������������� ���� ���� � ��� ���� ������� �������� ������ ��� ��

Explanation: This message suggest that the label dump outputbe reviewed.

Solution: Review the label dump output.

� SL tapes should have�����labels followed by������labels.

� The file ID in������should match the file ID in������or����.

��������� ���� ������������� ����������� ������ � �

Explanation: This messages suggests that��� ������be re-runwith the�����parameter.

Solution: Re-run��� ������with the�����parameter.

��������� ���� ������������� ��������������������� � ���������������� ���� ������������ ��������� ������ ����� ������� ������

Explanation: This message suggests that��� ������be re-runwith the���� ���parameter.

Solution: Re-run��� ������with the���� ���parameter.

��������� ����������� �� ������ ����������� �������� �������� ���

Explanation: While attempting to read an error record in thebackward direction no data was transferred. This may indicate apartial record at end-of-record.

Solution: None required.

MPSTTSC45 MPSTTSC49

188 MPST Messages and Codes Manual – Version 2.04

��������� � �������#����������� ��� ��! ��������������������� � ������!������������������

Explanation: A read backward command of an error recordcaused data transfer. From 1 to 80 bytes are printed.

Solution: None required.

��������� �� ������� ���� �������������������������������

Explanation: The��� ����function has started.

Solution: None required.

�������� �������������� �������������

Explanation: If���������is��������������������, the firstrecord of this file is a����������record.

If�������� is �������������, the first record of this file is a����record.

If���������is������������������������, the first recordof this file is an�����or�����record.

Solution: None required.

�������� ��������������� �����������������������"������ ���������������� �� ��� ��$ ��������

Explanation: After skipping over an error record, the nextoperation was either “read a tape mark” or an “error” whilereading the next record.

Solution: None required.

��������� ���������������#������ ���������! ������ ����������� ����������

Explanation: An incorrect record length was detected. ��������expected�����and received�����.

Solution: None required.

MPSTTSC50 MPSTTSC56

189 Chapter 17. MPSTTSC

��������� ������������������������������� ����������������������

Explanation: The�������of blocks counted by��������within file�����.

Solution: None required.

��������� �������������������� ���������������������������������������

Explanation: The�����should be the number of physicalblocks written in data file������preceding the trailer label at thetime of creation.

Solution: None required.

��������� ������������������������������������������������� ���������������

Explanation: The�������of files processed includes all���,�����, and������files.

Solution: None required.

��������� ����� ����������������� �����

Explanation: The forward space block command failed.

Solution: None required.

��������� ����� ������������

Explanation: The label dump utility completed successfully.

Solution: None required.

�������� �� ������ ������ �����

Explanation: The read forward command (02) failed.

Solution: None required.

MPSTTSC57 MPSTTSC61

190 MPST Messages and Codes Manual – Version 2.04

�������� ���������������������������

Explanation: Read forward command (02) failed whileattempting to read a record label.

Solution: None required.

��������� �����������������������������������������������������!������

Explanation: ��������has finished; the number of filesprocessed (���) includes��� ,�� ��� , and������files.

Solution: None required.

��������� ����������������������������"�������������!����������������������������������������������������������!������ ����������������������������������"��������������������������������"����������������� �������������������������������������������������������������������������������������������

Explanation: The����������������parameter will readall files and report any errors found. If a second error isdetected, unpredictable results may occur.

Solution: None required.

�������� �������������������������������������������

Explanation: The data following this message is the 17-bytefile ID field of��� �.

Solution: None required.

�������� ����������������������������������������

Explanation: The data following this message is the 17-bytefile ID field of������or�����.

Solution: None required.

MPSTTSC62 MPSTTSC67

191 Chapter 17. MPSTTSC

������ �� ������������������������������ ���������� ����� ��������

Explanation: The Julian day and year are retrieved from HDR1of the failing data set file. If the system date was properly set byoperations, this should be the date the failing data was created.

Solution: None required.

������ �� �������������������� ��������������������������� ���������������� ������������������������

Explanation: The last record within the data file failed.

This may indicate that a write data check or a write equipmentcheck �����’d the job during the creation phase.

Solution: Check the system and console logs for errors.

������ �� �������� �� ���������� ����������������������������������������������������������

Explanation: This messages suggests that the system andconsole logs be checked for any unusual conditions.

Solution: Check the system and console logs for unusualconditions such as: ������, re-IPL of CPU, or interventions.

������ �� ����� ����������� �����������������������������������������

Explanation: An error was detected reading a������label.

Solution: None required.

������ � ������������������������������������������������ ����

Explanation: The next I/O error will be the second sequentialerror in a row.

Solution: None required.

MPSTTSC68 MPSTTSC71

192 MPST Messages and Codes Manual – Version 2.04

�������� ���������������� ������

Explanation: Operator reply to a console message.

Solution: None required.

�������� ���������������������������������$��������������� ��� ��������%&�������������

Explanation: ���� ���detected that the tape is not fileprotected. ����� ���is a read-only function and can onlyprocess���������������tapes.

Solution: Reply to the message.

� If “ �” is entered, the function will ignore the write enabledcondition.

� If “ ” is entered, the function will unload the tape andprompt the operator to file protect the tape and remount.

� If “ �” is entered,����� ���will cancel.

�������� �����������"���������������!��"�������� �� �������������"��������#��������������������������� ���

Explanation: Blank tape was detected during the�������dumputility.

Solution: None required.

�������� �������������� ���������������$������� ���������������������������� ���������������!���������������� ���

Explanation: If the tape control unit does not have the blanktape detection feature installed, the tape can ’run away’ whenblank tape is read. This could cause a missing interruptcondition or it may cause an IFCC (interface control check)condition.

Solution: None required.

MPSTTSC72 MPSTTSC75

193 Chapter 17. MPSTTSC

������ � �������!��������������������������� �� �������������������

Explanation: If the tape was not closed out properly, it mayhave run off the end of the reel.

Solution: Check the label dump output.

������ � ������� �� ������� �� ����� ��������������� ����������� �� ������ ������������������������ ���������� ���������

Explanation: An interface control check has been received.

Solution: Ensure that the tape control units are still in properworking order.

������ � ������ ��������� ���������������� ���� ������� ���������!������� ������������ ��������

Explanation: No error conditions were encountered whilereading the record after the error.

Solution: None required.

������ ��"�������������������������� ��������� ��������������������!� ���� ������� �������

Explanation: The tape was not file protected.

Solution: Unload and file protect the tape. Remount the tape.Press any character on the keyboard to continue.

MPSTTSC76 MPSTTSC79

194 MPST Messages and Codes Manual – Version 2.04

��������� �������� ������������������������������� ������������������������������������� �����

Explanation: A block ID sequence error was detected withinthe label of this tape.

This may indicate that a prior write error has occurred andcaused this condition.

Solution: The tape may require re-initialization before it can bereused.

��������� �������� ������������������������������������ ������������������������

Explanation: A block ID sequence error was detected.

This may indicate that the last job that wrote to this tape did notcomplete properly.

Solution: Check the system and console logs for errors.

��������� �������� ����������������������� ��������� ������������������������������������ ������

Explanation: An incorrect length record was read within thelabel of this tape.

This may indicate that a prior write error has occurred andcaused this condition.

Solution: The tape may require re-initialization before it can bereused.

��������� � �����������������������������������������������

Explanation: This messages states that the tape will requirere-initialization before it can be reused.

Solution: Re-initialize the tape.

MPSTTSC80 MPSTTSC83

195 Chapter 17. MPSTTSC

�������� ����� ������������������������������������������������

Explanation: A read block ID command (22) has failed. Thesense data for this error follow this message.

Solution: None required.

�������� ������� ��������������������������������������������

Explanation: A locate block command (4F) has failed. Thesense data for this error follow this message.

Solution: None required.

�������� �������������������������������������� ��������������������������������������������

Explanation: No errors were detected while scanning anNL/NSL tape.

Solution: None required.

�������� ��������������������������������������������������������������������������������������� �������������

Explanation: The last record within the data file failed.

This may indicate that a write data check or a write equipmentcheck �����’d the job during the creation phase.

Solution: Check the system and console logs for errors.

MPSTTSC84 MPSTTSC87

196 MPST Messages and Codes Manual – Version 2.04

�������� �������������������������������������������������������������������������������������������

Explanation: A tape void was detected immediately after anerror record.

This may indicate that while this tape was being created asystem problem occurred and the CPU needed to be IPL’d.

Solution: Check the system and console logs for unusualconditions such as: ������, re-IPL of CPU, or interventions.

�������� ����������������������������������������������������������� �������

Explanation: The first error during input was PEOT.

This may indicate that the output job wrote into the physicalEOT (end of tape).

Solution: None required.

�������� ��������������������������������� �������������

Explanation: The record size exceeds the buffer size.

Solution: None required.

�������� ����������������������������������������������������������������������������������������������

Explanation: A sequence error was detected after an errorrecord.

This may indicate that while this tape was being created asystem problem occurred and the CPU needed to be IPL’d.

Solution: Check the system and console logs for unusualconditions such as: ������, re-IPL of CPU, or interventions.

MPSTTSC88 MPSTTSC92

197 Chapter 17. MPSTTSC

������ �� ������������������������������������ ���������������������������������������� ���������������������

Explanation: After the error record, the beginning of the nextrecord is printed. A maximum of 80 bytes of data aretransferred. This data may help determine if “old data” was thecause of the first error.

Solution: None required.

������ � ������������������������������������ ���� ����������� ������������ ���

Explanation: An incorrect length record was detected withinthe data set. All data set records are checked for block size ifrecord format was variable or fixed.

Message����������follows this message.

Solution: None required.

������ � ���������������������� ������������� ������ ���������������������������� ����������

Explanation: The record��������for file������is incorrect.Message����������follows this message.

Solution: None required.

������ � ����������������������

Explanation: Parameter (����) is either coded incorrectly or isinvalid for the��� ����command for the��������function.

Solution: Enter the��� ����command using the correctparameter.

������ � ������������ �����������������

Explanation: The record read had a length of�����bytes.

Solution: None required.

MPSTTSC93 MPSTTSC98

198 MPST Messages and Codes Manual – Version 2.04

��������� �� ����������� � ��������� ������������ ������� ��� � ������

Explanation: Multiple errors were detected; the analysis of thefirst error cannot be completed.

Solution: None required.

��������� �������� �� �� ����

Explanation: The expected block����was received. It is +1from the last readable record.

Solution: None required.

��������� ��������� �������������� �������������� �

Explanation: The block �� read from the tape was writtenwhen the record was created. If the����read is out of sequencewith the prior record (indicating “old data” was read), a�����

������ ����error (ERPA code 41) will occur.

This may indicate that the output job did not complete normallyor was not closed out properly. It may also indicate thatsubsystem error recovery positioned the tape at an unexplainedsection of the tape.

Solution: None required.

��������� ���� ��������

Explanation: This message is issued in response to a�������

���������command requesting the current value of��������.

Solution: None required.

MPSTTSC99 MPSTTSC102

199 Chapter 17. MPSTTSC

��������� ������������������������������������������������������������������������������� ������������������� �������������������������������������������������������� ������������������������������������������������������������������������

Explanation: This warning is placed on the reports if SL tapesare being processed.

���� ���attempts to process SL labels as IBM or ANSIstandard. Tapes that use an 80-byte�����record as the firstrecord on the tape will be treated as an SL-labeled volume.

Any other types of labels, that begin with a�����record, maycause unpredictable results.

Solution: None required.

���������� ������������������������ ������ ��������������� ���������������� ����������� ������������

Explanation: ���� ���will attempt to proceed to thevoid/physical EOT after skipping the 1st record after a doubletape mark.

Solution: None required.

���������� ���������� ����������������������� �������

Explanation: The number of double tape marks processed by���� ���is����.

Solution: None required.

���������� ����������������������������������������� ��������������

Explanation: ���� ���has finished; the number of filesprocessed (���) includes����,��������, and������files.

Solution: None required.

MPSTTSC103 MPSTTSC208

200 MPST Messages and Codes Manual – Version 2.04

���������� ������������������������������������������ �������

Explanation: �������has finished; the number of filesprocessed (���) includes����,� ������, and��� ��files.

Solution: None required.

���������� ����������������������������������������������������������

Explanation: �������has finished. There were too manyerrors found and� �������will not continue past this volume.

Solution: None required.

���������� ���������� ���������

Explanation: The last ERPA code received was�����.

Solution: None required.

���������� ���������������������������

Explanation: The���� ����process has started.

Solution: None required.

��������� ����� �������������������������������

Explanation: The record count was�����just before thecounter was reset.

Solution: None required.

201 Chapter 18. MPSTVSC

Chapter 18. MPSTVSC

Volume Scan (VOLSCAN) Messages

All MPST functions and diagnostics use standard I/O operationchecking routines and these routines issue standard messages forerrors. Error message numbers are issued according to whichfunction or diagnostic was being run when the error occurred.

Hint: To make finding the messages easier, both the messagenumber and the message text are bold.

The following messages are issued for Volume Scan:

MPSTVSC00 MPSTVSC03

202 MPST Messages and Codes Manual – Version 2.04

��������� ����� ������������ ������������������������������������� �������������� ���������������

Explanation: The���������function is executed on the deviceat address������with volume serial number������. Thedevice� ���is:

� 3330–1 (3330 Mod 1), 3330–11 (3330 Mod II)

� 3350 C1 (3350 in 3330 Mod 1 compat mode), 3350 C11(3350 in 3330 Mod 11 compat mode), 3350 N (3350 innative mode)

� 3380, 3380E (3380 2X), 3380J, 3380K

� 3390-1, 3390–2, 3390–3, 3390–9

Solution: None required.

��������� � � �����������������

Explanation: The parameter�����is either coded incorrectlyor is invalid for the���������function.

Solution: Enter the command using the correct parameter.

��������� ������������

Explanation: An I/O error occurred while attempting toexecute a sense (04) command.

Solution: Retry the command. If the problem persists, notifyCS Software Support.

�������� ��������������������������������������

Explanation: The���������function terminated because theend of a VM/370 mini-disk, or the end of a 4305 in 3380 mode,was detected. ���.���is displayed in decimal and hex.

Solution: None required.

MPSTVSC04 MPSTVSC06

203 Chapter 18. MPSTVSC

��������� ���� ��� � ������� � ���������

Explanation: The value specified for the��������or the�������parameter is not valid for the device being tested.

Solution: Correct the value and retry the command.

��������� ����� ���� ������������������

Explanation: The test device failed to open, the test device isnot a DASD device, or the program does not recognize the typeof DASD.

Solution: Verify that the first test device defined is codedcorrectly.

��������� ����������

Explanation: An I/O error occurred while reading a datarecord. � ������is executing in������mode. In this mode,a random record on a track is read.

Solution: Try scanning in normal mode to see if the error ispermanent.

MPSTVSC07 MPSTVSC07

204 MPST Messages and Codes Manual – Version 2.04

�������� ������������������������������������������������

���������������������������������������������������

���������� ���

����� ��������������� ��� �����

������ �������������������������������������������������������������� ���

Explanation: This message prints a table of errors by head anda table of errors by type. Only one error will be counted pertrack and errors encountered during retry do not appear in thistable.

The���������������table lists the total number of errorsencountered for each head and the total number of defect skipsassigned for all tracks scanned for that head and the total numberof tracks that had any defect skips assigned. The head number islisted in decimal and in hexadecimal.

The��������������table lists the total number of errors forall tracks scanned for each format error type. ������errors areerrors which are not format 0 through format 8 errors.Correctable format 4 errors are counted as format 5 errors here.Format 6 errors are not presented.

Solution: None required.

MPSTVSC08 MPSTVSC11

205 Chapter 18. MPSTVSC

������ � ����� ������������������������������������������� ���������������������������������������

Explanation: This message prints a table of cylinders witherrors by head. The head number is listed in decimal andhexadecimal. If the message� ������������is also printed,more than 512 errors occurred.

Solution: None required.

������ �� ���������������� ��������� �����

Explanation: A�����command was entered and accepted bythe��������function and��������terminates.

Solution: None required.

������ � ���� ��������������������������������� ���

Explanation: �������is unable to continue because anunrecoverable error occurred. An unrecoverable error could be achannel error or intervention required.

Solution: If intervention is required, correct the condition andrestart the program.

������ ���� �������������������������������� ���

Explanation: No errors were detected by the�������

function on the device at address������with volume serialnumber�������.

Solution: None required.

MPSTVSC12 MPSTVSC15

206 MPST Messages and Codes Manual – Version 2.04

��������� ����������������������� ������� ������ � �� �

Explanation: Correctable/temporary errors were detected by��������on the device at address������with volume serialnumber�������.

Solution: This message indicates problems that should beinvestigated at the next scheduled maintenance period. TheMPST printer output should be retained and given to CSSoftware Support.

��������� ����������������������� ��� � ������� � �� �������� �� ��� ����� ������������

Explanation: Device errors were detected by���������on thedevice at address������with volume serial number�������.

Solution: This message inidcates problems that should beinvestigated as soon as possible. The MPST printer outputshould be retained and given to CS Software Support.

��������� ��� ����� ������� ������� �����

Explanation: The CE cylinder could not be scanned due to anerror in the parameter list.

Solution: Notify CS Software Support.

��������� ���� �������

Explanation: An I/O error occurred while attempting toexecute a sense ID (E4) command.

Solution: None required.

MPSTVSC16 MPSTVSC18

207 Chapter 18. MPSTVSC

�������� ����������������������������������������������������� ����

Explanation: Correctable data checks were detected by��������on the device at address������with volume serialnumber�������.

Solution: This message indicates possible problems that shouldbe investigated at the next scheduled maintenance period. TheMPST printer output should be retained and given to CSSoftware Support.

�������� ����������������������������������������

Explanation: No problems were detected by the��������

function on the device at address������with volume serialnumber�������.

Solution: None required.

�������� ������������

Explanation: An I/O error occurred while attempting toexecute a read device characteristics command.

Solution: None required.

MPSTVSC20 MPSTVSC20

208 MPST Messages and Codes Manual – Version 2.04

�������� ����������������������������� �������������������������������������������������������������� ����������������������������� ����������������������

Explanation: An error occurred while attempting to read thehome address (HA) and record zero (R0) of the alternate trackthat is assigned to this defective track. The address of thealternate track found in the count field of the defective track isprinted with the error information.

� �����—The cylinder/head address in decimal andhexadecimal.

� ��—The CPU id.

� ���—The actual path where the error occurred.

� �����������—The unit and channel status from theCSW.

� ��—The condition code.

� � �����—The ECB completion code.

� ����������—The sense bytes.

Solution: The MPST printer output should be retained andgiven to CS Software Support.

MPSTVSC21 MPSTVSC23

209 Chapter 18. MPSTVSC

����������� ������������������������� ������������ ���������������������������������� �����������������

Explanation: An error occurred while reading the track.

� �����—The cylinder/head address in decimal andhexadecimal.

� �—The CPU id.

� ����—The actual path where the error occurred.

� ����������—The unit and channel status from theCSW.

� ����� ��—The ECB completion code.

� ����������—The sense bytes.

Solution: The MPST printer output should be retained andgiven to CS Software Support.

��������� ���������������������� ������������������

Explanation: An error occurred reading the home address (HA)and the record zero (R0) of this track.

Solution: The MPST printer output should be retained andgiven to CS Software Support.

��������� ���������������������� ��������� ����������������������

Explanation: An error occurred reading record number�����

(decimal) or���������(hexadecimal) of this track. ���������is the retry count for�����.

Solution: The MPST printer output should be retained andgiven to CS Software Support.

MPSTVSC24 MPSTVSC27

210 MPST Messages and Codes Manual – Version 2.04

��������� ���������������������������� � ���������������������������������

Explanation: The track is flagged as a defective track, and thealternate track assigned is listed in decimal and hexadecimal.

Solution: None required.

��������� ����������������������� �����������

Explanation: The track is an alternate track that is flagged asdefective.

Solution: None required.

��������� ������������������������ ���� ����������������� ������������������ �������������������

Explanation: The track is an alternate track and an erroroccurred while reading the home address (HA) and the recordzero (R0) of the defective track.

Solution: None required.

�������� ����������������������� ���������

Explanation: Two possible conditions may exist:

� The track was flagged as defective, but the alternate trackpointed to does not point back to the defective track.

� The track is an assigned alternate, but the defective trackpointed to by this alternate track does not point back to thealternate.

Solution: None required.

MPSTVSC28 MPSTVSC29

211 Chapter 18. MPSTVSC

��������� ����������������� �������� �������������������� �����������

Explanation: The count field of the record read was not instandard format. The actual record count field is printed ascylinder (��), head (��), record (�), key (�), and data (��).

The following possible conditions could exist:

� R0 is a file mark (data field length equals zero).

� The record number of this record is less than or equal tothe record number of the previous record read (indicatingduplicate or out-of-sequence records).

Solution: None required.

��������� ��������������������������������������������������������������������

Explanation: Home address (HA) and record zero (R0) wereread without error, but were not in standard format. Thefollowing possible conditions could exist:

� Bits 0–5 of the HA flag byte are not zero.

� The cylinder or the head address is not correct.

� The R0 count field record number is not zero.

� The R0 record has a key field.

� The R0 record data field is not 8 bytes.

The record zero field is: flag/cylinder/head.

The home address field is: cylinder/head/record/key/data_length.

Solution: None required.

MPSTVSC30 MPSTVSC33

212 MPST Messages and Codes Manual – Version 2.04

�������� ����������������������������������� ��������������

Explanation: An error occurred when reading this track, butwhen the records on the track were re-read, one at a time, theerror did not recur.

Solution: None required.

�������� �������������������������������

Explanation: The maximum number of retries specified by the� ��parameter has been reached without retry being successful.� ������terminates scanning of the current record and proceedsto the next track to be scanned.

Solution: None required

�������� ������������������������������� ������������������������������������

Explanation: The track is an assigned alternate track and thedefective mate to which this track is assigned is listed.

Solution: None required.

�������� ���������������������������������������

Explanation: An error occurred attempting to obtain the defectskip data for this track. �� �����is the retry count for�� �.

� For a 3350 type device�������is�������������

� For a 3380 type device�������is�����������

Solution: None required.

MPSTVSC34 MPSTVSC36

213 Chapter 18. MPSTVSC

�������� ������������������������������������������ ������������

Explanation: The following possible conditions could exist:

� The home address (HA) or record zero (R0) record couldnot be read.

� The number of permanent errors that occurred whilereading data records exceeded the number specified by the����� �parameter.

Scanning of that track terminates and scanning of the next trackbegins.

Solution: None required.

�������� �����������������

Explanation: The number of errors encountered whileexecuting������������ has exceeded the maximumallowed by the������ �parameter and testing terminates.

Solution: None required.

�������� ����������������������������������������������������

Explanation: A status of unit exception was received on a readmultiple CKD command. Unit exception on CKD DASDindicates an end of file mark was encountered. On a readmultiple CKD command, the end of file mark should betransferred to the system as part of the data.

Solution: None required.

MPSTVSC37 MPSTVSC52

214 MPST Messages and Codes Manual – Version 2.04

�������� �����������������������������������������������������������

Explanation: An invalid track format was detected and nofurther testing will be attempted. Invalid track format bypasses����checking and immediately skips to the next track.

Solution: None required.

�������� ������������������������������������������

Explanation: This track of a 3350 type device was scanned andthe defect skip information was read from home address (HA)and printed.

� ��specifies the location of the first defect on the track,�� �

specifies the location of the second defect on the track, and�� �

specifies the location of the third defect on the track

Solution: None required.

�������� �������������������������������������������

Explanation: This track of a 3380 type device was scanned andthe defect skip information was read from home address (HA)and printed. ������is a decimal value.

� ��specifies the location of the first defect on the track,�� �

specifies the location of the second defect on the track, and . . . � ��specifies the location of the seventh defect on thetrack

Solution: None required.

�������� ��������������������������������������� ��

Explanation: The defect skip data for this track is not availabledue to errors. This message is preceded by message��� �� ���

which describes the error.

Solution: None required.

MPSTVSC60 MPSTVSC62

215 Chapter 18. MPSTVSC

�������� ������������������������������������������

Explanation: A Sense ID command (X’E4’) was issued to thetest device. The data, if any, returned by this command isdisplayed in this message. This message indicates����

��������if:

� The test device command rejects this command.

� The first byte of data returned is not ��.

� The number of bytes returned is other than seven.

� An I/O error occurs.

If an I/O error, other than command reject occurs, it is reportedby message� �������.

The Sense ID data is printed as:

� ������—The control unit type (2 bytes).

� �������—The control unit model (1 byte).

� �������—The device type (2 bytes).

� ��������—The device model (1 byte).

Solution: None required.

�������� ���������������

Explanation: The device for��������has no valid CEcylinder.

Solution: None required.

�������� ��������������������������

Explanation: The device for��������has no defect skipinformation available. Parameter forced off.

Solution: None required.

MPSTVSC63 MPSTVSC91

216 MPST Messages and Codes Manual – Version 2.04

��������� �������� �������� ������� ���������

Explanation: The��������������command has beenprocessed and� �����terminates.

Solution: None required.

��������� ���������� �����

Explanation: The��� ���������parameter was specified, butthe device is not defined.

Solution: If the first device defined is not the device to be used,specify the correct address or DD name.

��������� ��������������������

Explanation: The��� ���������parameter specified does nothave a path available.

Solution: Select another device.

��������� ������ �����

Explanation: The��� ���������parameter specified is notenabled.

Solution: Enable the device and try again.

�������� ��������������������

Explanation: Parameter (����) is either coded incorrectly or isinvalid for the��������command for the� �����function.

Solution: Enter the command using the correct parameter.

MPSTVSC96 MPSTVSC99

217 Chapter 18. MPSTVSC

��������� ������������������������������

Explanation: The��������command������� �was issued to�����.

Solution: None required.

��������� ����������������������������������������

Explanation: The������������������is not supported by the������function.

Solution: None required. �������and������� �are the onlyvalid��������parameters.

��������� ��������������������� �����������������������������

��������������������� ��������������������������

��������������������� �����������������������

Explanation: Program check failed.

Solution: The MPST printer output should be retained andgiven to CS Software Support.

218 MPST Messages and Codes Manual – Version 2.04

219 Chapter 19. MPSTVTM

Chapter 19. MPSTVTM

Terminal Control Unit Verification (VTERM) Messages

All MPST functions and diagnostics use standard I/O operationchecking routines and these routines issue standard messages forerrors. Error message numbers are issued according to whichfunction or diagnostic was being run when the error occurred.

Hint: To make finding the messages easier, both the messagenumber and the message text are bold.

The following messages are issued for Terminal Control UnitVerification:

MPSTVTM00 MPSTVTM04

220 MPST Messages and Codes Manual – Version 2.04

��������� ��������� �������������� ���� �

Explanation: The terminal control unit verification test hasstarted.

Solution: None required.

��������� �������������������������� ��

Explanation: The test device must be defined as a type 5 DDcard.

Solution: Redefine the test device.

��������� ��� � ������������������ ������������

Explanation: The memory allocation for a 4k I/O buffer failedand the function terminates.

Solution: Increase memory or reduce the number of concurrenttasks that are running.

��������� ���������� ����� �����

Explanation: The full pattern ripple display test has started.

Solution: None required.

��������� �� � ��������������� �����

Explanation: The individual character display test has started.

Solution: None required.

MPSTVTM05 MPSTVTM09

221 Chapter 19. MPSTVTM

��������� ���������������������� ������������������� ������

Explanation: The data read from the screen buffer was notwhat was expected. The data at byte�����should have been��.

Solution: Repeat the test using a different monitor. If theproblem persists, the controller is in error. This is a severe errorindicator.

��������� ��������������������������������������������

Explanation: This message is displayed on the console.

Solution: Look at the test monitor and confirm the screencontents.

��������� ������������������������������������ �����

Explanation: The user indicated that the previous display wasincorrect and the function terminates.

Solution: None required.

��������� ������������������������������

Explanation: The user indicated that the previous display wascorrect and the function continues.

Solution: None required.

��������� ��������������������������� �����

Explanation: An I/O error occurred and the test terminates.

Solution: None required.

MPSTVTM10 MPSTVTM14

222 MPST Messages and Codes Manual – Version 2.04

��������� ����������������������������

Explanation: The user has been prompted to enter a singlecharacter on the test device.

Solution: User enters the prompted character at the testterminal.

��������� �����������������������������������

Explanation: The user entered character���on the test deviceand character���is now being displayed.

Solution: None required.

��������� ���������������������������� �����

Explanation: The terminal control unit verification test hasbeen terminated.

Solution: None required.

��������� ������������������� ��������������� �����

Explanation: The LMU must be disconnected from itscontroller and replaced with a standard 3278 terminal beforebeginning this test series.

Solution: Attach the 3278 terminal and/or ensure that thecorrect location was entered in the device definition.

��������� ������������������������������������������

Explanation: An invalid key was pressed or an invalidcharacter was entered for the test sequence.

Solution: Enter a valid LMU character. Valid characters consistof upper case alphabet, numbers 0–9, and the characters < > ( ) ?and blank. Or, press��F3� to terminate the test.

223 Chapter 20. MPSTWRC

Chapter 20. MPSTWRC

Write-Read Cartridge (WRCART) Messages

All MPST functions and diagnostics use standard I/O operationchecking routines and these routines issue standard messages forerrors. Error message numbers are issued according to whichfunction or diagnostic was being run when the error occurred.

Hint: To make finding the messages easier, both the messagenumber and the message text are bold.

The following messages are issued for Write-Read Cartridge:

MPSTWRC00 MPSTWRC02

224 MPST Messages and Codes Manual – Version 2.04

��������� ���� �� ���������

Explanation: The�������function will be executed on thedevices listed by message���������.

Solution: None required.

��������� ��� � �� �����������

Explanation: The parameter (����) is either coded incorrectlyor is invalid for the�������function.

Solution: Enter the correct parameter.

��������� �������������� ��������������� �������������� �������

Explanation: Device �� at address������with volumeserial number����configured without error.

Solution: None required.

MPSTWRC03 MPSTWRC03

225 Chapter 20. MPSTWRC

�������� ������������������������������������������������������������������������������������������ ��������������������������������������������������������������������� ������������

�����������������������������������������������

�������������������������������������������������������������������������������������������������� �����������

������������������������

��������������������������������������������������������������������������������������� �������������������������������������������

�������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������

MPSTWRC04 MPSTWRC04

226 MPST Messages and Codes Manual – Version 2.04

��������������������������������������������������������������������������������������������������

Explanation: The summary for this execution of�������fordevice����at address������with volume serial number�����is printed.

� The number of passes executed and the number of recordsand tape marks processed is listed along with the totalnumber of compare, sequence, temporary, and permanentread and write errors.

� The total elapsed time is the time used for all passes.

� The total bytes transferred, written, and read are also listed.

� If the�������� �parameter was specified, the number ofcontrol units detected (����) functions for read andwrite temporary, erase gap, and read and write transienterrors are listed.

� If���������� �is specified, these counts are zero (0).

� If������is active, the counts for������functions arelisted; otherwise they are zero (0).

Solution: None required.

��������� ����� ������ ����

Explanation: No test devices were configured for thisexecution of������.

Solution: Verify defined devices.

MPSTWRC05 MPSTWRC07

227 Chapter 20. MPSTWRC

��������� � ��������� �� �� �������� ����� ���������� �����������

Explanation: A���������for a portion of memory to be usedfor data comparison failed. Data comparison cannot be done.

Solution: For data comparison, increase the size of the regionor partition where MPST is executing and then re-execute.

��������� �������� ��������� ���� ��������������

Explanation: The�� ����parameter specified a value of lessthan 28 or greater than the maximum size allowed. The� ����parameter was changed to reflect the correct range for����.

� On MVS either��������or the device maximum is themaximum������allowed.

� On the PC������ is the maximum������allowed.

� On VM either��������or the device maximum is themaximum������allowed.

Solution: None required.

��������� ���� ��������

Explanation: An I/O error occurred during configuration.

This may occur when attempting to overwrite a tape using anon-expanded format device if the tape was previously writtenusing an expanded format device.

Solution: Initialize the tape with a tape mark using anon-expanded format device to correct the problem.

Warning: Initializing the tape with a tape mark will result in allexisting data on the tape being lost.STOP

MPSTWRC08 MPSTWRC08

228 MPST Messages and Codes Manual – Version 2.04

��������� ���������������� ��� ���������������

Explanation: Device�������was not configured. ��������for not configuring:

� �����������������—The test device DD card is not atype 5 DD card.

� �� ����� �������� ��������—The drive isassigned to another path.

� ���������—A test sequence with a write pass wasspecified but the cartridge is file protected. No testing canbe done on this device.

� ����� ����� �������� ��—A����� ��for a20K I/O buffer failed. Increase the size of the region orpartition in which MPST is executing.

� �������—An I/O error occurred during configuration.The error was described in message����������.

� ������������������� �—No device has beendefined for this DD name.

� ����� ��—An open for the device failed.

� ���������������� ��������—The cartridge volumemounted on this device contains a valid OS tape label.Testing cannot be done on this device.

� ��������������� ������—Device characteristics readdo not match the DD type specified.

� ����� ��—Unable to get sense data from the device.

� ������ ����������� ��—The test device DD carddoes not define a cartridge device.

Solution: Verify that the test devices are correctly defined,online and available.

MPSTWRC09 MPSTWRC13

229 Chapter 20. MPSTWRC

����"��� ��� ��� ����� �������������������!�����������"��������������

Explanation: �� ���parameter detected but�������was notdefined. Volume serial number������will be ignored.

Solution: None required.

����"���� �������������$��������������#�� ����������

Explanation: If the block size specified by the���� ����parameter is less than 4098, the time to execute��������tocompletion may be very long.

Solution: None required.

����"���� ����������������� ���� �������������

Explanation: The number of passes specified by the���

parameter has been completed for device�������at address�����with volume serial number�����. Testing hasterminated on that device but continues on other devices.

Solution: None required.

����"���� ������������������������� ������ ������� ���

Explanation: �������has detected that a������command wasentered at the operator’s console. Testing on test device������

at address������with volume serial number������has beenstopped.

Solution: None required.

����"���� ����������������������� ����� �������������������

Explanation: Testing on test device�������at address�����with volume serial number������has been terminated due toa permanent error.

Solution: None required.

MPSTWRC14 MPSTWRC15

230 MPST Messages and Codes Manual – Version 2.04

��������� ������������������������� ����� ��������� ��� ���������������������������

Explanation: The��������parameter requested a larger blocksize than the device can handle. The block size has beenchanged to the correct�����for this device.

� On MVS either��������or the device maximum is themaximum�����allowed.

� On the PC������ is the maximum�����allowed.

� On VM either��������or the device maximum is themaximum�����allowed.

Solution: None required.

��������� ����������������������� ���������������� ����������� �� � �

Explanation: ���commands issued to configure the devicewere rejected.

Solution: Verify that the device has the current level ofmicrocode.

MPSTWRC19 MPSTWRC19

231 Chapter 20. MPSTWRC

��������� �� �������������������������������� ���������� �� ����������������� ��������������������

�������������������� ��

Explanation: This message identifies the tape drive that iscreating the cartridge.

� The drive reading the cartridge is identified by �� ����

and drive address �����.

� The drive that created the cartridge is identified by�� ����, drive address �����, control unit serial number���� , tape drive physical address ��������, and tapedrive logical address �������.

� The time is specified by hour:minute:second (������)and the date is specified by month:day:year (����������).They identify when the write pass started.

� ���is the number of records per file.

If this device is a Model 3490E, the characters ’3490E’ willfollow� ��.

Solution: None required.

MPSTWRC20 MPSTWRC21

232 MPST Messages and Codes Manual – Version 2.04

�������� �� ���������������������������������������� ����������������� ��������������������

�������������������� ��

Explanation: This message identifies the tape drive that createdthe cartridge being read.

� The drive reading the cartridge is identified by �� ����

and drive address �����.

� The drive that created the cartridge is identified by�� ����, drive address �����, control unit serial number���� , tape drive physical address ��������, and tapedrive logical address �������.

� The time is specified by hour:minute:second (������)and the date is specified by month:day:year (����������).They identify when the write pass ended on the creatingdrive if the current pass is a read backward.

� �� is the number of records per file.

Solution: None required.

�������� ��� ��������������������������������������������������� ���

Explanation: Incorrect status was received for an I/O operationto device���� ��at address������during a������pass. Theactual status received was������and the command executed was���.

Solution: None required.

MPSTWRC22 MPSTWRC25

233 Chapter 20. MPSTWRC

�������� ������������������������ �� �������� �������� �������������

Explanation: A read forward pass is being executed on the testdevice� ����at address�����but the BOT label on thecartridge is not a BOT label that������writes on a testvolume. Testing on the device terminates.

Solution: None required.

�������� ������������������������������

Explanation: A data record was expected but an EOT label wasread. The tape mark separating the data records and the EOTrecord was missed on a read forward pass of the cartridge on testdevice� ����at address�����with volume serial number����. Testing on the test device terminates.

Solution: None required.

�������� ���������������������������������� �� ��

Explanation: The cartridge on test device� ����at address����with volume serial number������is missing the EOTlabel that������writes on a test volume. Testing on thedevice terminates.

Solution: None required.

�������� ����������������������������������������� ��������� �������

Explanation: The number of blocks read (����) does notcompare with the number of blocks written ( ����) as listed inthe EOT label for the cartridge on test device� ����at address����with volume serial number�����. This is the equivalentof an����������. Testing on the test device continues.

Solution: None required.

MPSTWRC26 MPSTWRC29

234 MPST Messages and Codes Manual – Version 2.04

�������� ����������������������������������������

Explanation: During a read backward pass on the cartridge ontest device�������at address������with volume serial number����, the first record read was not the EOT label as expectedor the EOT record was not found after skipping a maximum ofthree tape marks. Testing on the test device terminates.

Solution: None required.

�������� ������������������������� �������������������

Explanation: A read backward pass is being executed on testdevice�������at address������with volume serial number����. The EOT label was read successfully but the nextrecord on the cartridge was not the tape mark preceding the EOTrecord. Testing on the device terminates.

Solution: None required.

�������� �������������������������������

Explanation: A data record was expected but a BOT label wasread on a read backward pass of the cartridge on test device������at address������with volume serial number�����.(The tape mark separating the data records and the BOT recordwas missed.) Testing on the device terminates.

Solution: None required.

�������� ����������������������������������������

Explanation: The cartridge on test device�������at address�����with volume serial number������is missing the BOTlabel that��������writes on a test volume. Testing on thedevice terminates.

Solution: None required.

MPSTWRC30 MPSTWRC33

235 Chapter 20. MPSTWRC

�������� ���������� �����������������������������������

Explanation: The last pass executed on test device�����ataddress�����with volume serial number� ����was not awrite pass, a read forward pass, or������is active and���������was not specified. A read backward pass cannot beexecuted and testing on the test device continues.

Solution: None required.

�������� ���������� ����������� ���� ����������������������������������������������������������

Explanation: A record was read on test device�����ataddress�����with volume serial number� ����that was notthe length expected. �������expected record number�������

to have�������bytes but������bytes were received.

Solution: None required.

�������� ������������������� ������������������������������������������

Explanation: An exchange point was reached for test device����at address����.

Solution: Reply with any character when the cartridge volumeshave been exchanged and the drive is made ready.

�������� �����������������������������������������������

Explanation: An open for test device�����at address����failed after the cartridge volumes were exchanged. Testing onthe device terminates.

Solution: None required.

MPSTWRC34 MPSTWRC37

236 MPST Messages and Codes Manual – Version 2.04

��������� ��������������������������� ��������������� ��������������� ������

Explanation: The first record on the cartridge, mounted on testdevice������at address�����, after an exchange point was nota BOT label record written by the� ����function. Testing onthe device terminates.

Solution: None required.

��������� ������������������������������������������ ��� ��������� ��� �

Explanation: A sequence error occurred on test device�����

at address������with volume serial number������.� ���expected��� ��but read��� �, where���and���are either�����or��������� �.

Solution: None required.

��������� �������������������� ����� ������������������ ������������� ��������������������� ������������

Explanation: The ID fields (the first and last eight bytes) donot match for record�����on test device������at address�����with volume serial number������.

� ���������is the first eight bytes of the record.

� ���������is the last eight bytes of the record.

Solution: None required.

��������� �������������������������������� ��� ���

Explanation: A short record was read on test device������ataddress������with volume serial number������. A dump ofthe record follows this message.

Solution: None required.

MPSTWRC38 MPSTWRC40

237 Chapter 20. MPSTWRC

��������� ����������������������������������������� ������ � ������������ ������ �����

Explanation: A sequence error occurred on test device������

at address�����with volume serial number������mounted. �������expected record� ����but received record�����.

Solution: None required.

�������� ���������������

Explanation: The actual data read from a record did not matchthe expected data for that record.

Solution: None required.

��������� ������������������ ������������������ � ������������������������

Explanation: A read forward pass has started for device������

at address����. The cartridge was written in ICRC format andthe drive is not capable of ICRC.

Solution: Move the cartridge to a device that is ICRC capable.

MPSTWRC41 MPSTWRC42

238 MPST Messages and Codes Manual – Version 2.04

�������� �����������������������������������������

�����������������������������������������������

����������������������������������� �����������

������������������������������������� ��������������������������

���������������������������������������������������������������������������������������������������������

Explanation: A write pass has been completed for device������at address������with volume serial number�����.The summary report for the write pass is contained within thismessage.

If������is active, the counts for������functions are listed;otherwise, they are zero.

Solution: None required.

�������� ���������������������������������������������������������

Explanation: The summary information for all passes for testdevice�������and tape volume serial number������is notbeing kept.

Solution: None required.

MPSTWRC43 MPSTWRC43

239 Chapter 20. MPSTWRC

�������� ����������������������������������������������

�����������������������������������

���������������������������������������������������������������� �����������

�������������������������������������������

������������������������������������������������������������������������������

Explanation: A read forward pass has been completed fordevice�������at address������with volume serial number����. The summary report for the read forward pass iscontained within this message.

If������is active, the counts for������functions are listed;otherwise, they are all zero.

Solution: None required.

MPSTWRC44 MPSTWRC45

240 MPST Messages and Codes Manual – Version 2.04

��������� ������������������������������������� ���������

��������������������������� ������

�������������������������������������������������������������������

�������������� ������������� ������������������������

Explanation: A read backward pass has been completed fordevice�������at address������with volume serial number����. The summary report for the read backward pass iscontained within this message.

Solution: None required.

��������� ������������������������������������������������������������������

Explanation: A read backward pass has started for device������at address�����. The cartridge was written in ICRCformat and the drive is not capable of ICRC.

Solution: Move the cartridge to a device that is ICRC capable.

MPSTWRC50 MPSTWRC50

241 Chapter 20. MPSTWRC

��������� �������� ����� �������� ���� �������������� � ���������� ����� ����������������������������������������������������������� ��������

Explanation: A temporary error was detected and the controlunit is in forced logging mode on test device������at address��� �with volume serial number����� �mounted.

� ����� ��—The record number of the record on whichthe error occurred.

� ���������—The number of bytes transferred at thetime of the error.

� ���������—The number of times the operation hasbeen retried.

� ������—The channel command being executed.

� ���������—The SIO condition code.

� �������������—The unit and channel status for CSW.

� ������—The CPU ID of the CPU on which the erroroccurred.

� ���������—The actual channel path on which the erroroccurred.

� � �������—The sense bytes.

Solution: None required.

MPSTWRC51 MPSTWRC51

242 MPST Messages and Codes Manual – Version 2.04

��������� ������������ ����������� �������� ������������������������

��������������������������������������������� ����� ��������������������������������������������

Explanation: A temporary error has occurred on test device������at address������with volume serial number�� ����at��������������������

� �������—The record number of the record on whichthe error occurred.

� ���������—The number of bytes transferred at thetime of the error.

� � �� �����—The number of times the operation hasbeen retried.

� ������—The channel command being executed.

� �������� ��—The SIO condition code.

� �������������—The unit and channel status for CSW.

� �����—The CPU ID of the CPU on which the erroroccurred.

� ���������—The actual channel path on which the erroroccurred.

� ����������—The sense bytes.

Solution: None required.

MPSTWRC52 MPSTWRC52

243 Chapter 20. MPSTWRC

��������� ���� ������������������������ ������ ����� ��������

�������������������� ������������ ������ ���� ������������������������������������������������������� �����

Explanation: A permanent error has occurred on test device���� �at address������with volume serial number�������.� ��� �������� indicates the date and time the erroroccurred. �����indicates an error condition of either ��������or���������.

� ���������—The record number of the record on whichthe error occurred.

� ��������� —The number of bytes transferred at thetime of the error.

� ���������� —The number of times the operation hasbeen retried.

� ���� �—The channel command being executed.

� �����������—The SIO condition code.

� �������������—The unit and channel status for CSW.

� � ����—The CPU ID of the CPU on which the erroroccurred.

� �������—The actual channel path on which the erroroccurred.

� �����������—The sense bytes.

MPSTWRC52 MPSTWRC52

244 MPST Messages and Codes Manual – Version 2.04

� �������������is a message describing the error. Somepossible messages and their meanings are:

� �������������������—The channel status byte ofthe CSW indicated a channel-type error.

� ������—The event control block (ECB) completioncode was not 7F (no error) or 41 (permanent error).Any other ECB code is a fatal error.

� �������������������—The error was not a datacheck or an overrun. Data checks and overruns areretried. All other errors are considered permanent.

� ��� ����������������—Read error recovery failedto recover from a temporary read error. The error isnow a permanent error.

� ��� ����������������—Write error recoveryfailed to recover from a temporary write error. Theerror is now a permanent error.

� ��������������� �������—The error occurredduring read error recovery. ��� is the commandwhich failed during retry.

� �����������������—The failing CCW could notbe determined and no recovery action could be taken.

� ��������������� �������—The error occurredduring write error recovery. ��� is the commandwhich failed during retry.

Solution: None required.

MPSTWRC53 MPSTWRC56

245 Chapter 20. MPSTWRC

�������� ���������� ����������������������������������

Explanation: Following a sequence error,�������attempts toget back in sync by resetting the record expected based upon therecord just processed. If the record read is more than eight off ofthe record expected, the error is too great to correct in thismanner.

Solution: None required.

�������� ���������� ��������������������������� �������������������������������

Explanation: The����������� �command issued to device�����at address�����with volume serial number� ���failed.

Solution: None required.

�������� ���������� ��������������������������������������� �������������

Explanation: An error occurred on device������at address����with volume serial number� ���. The ERPA code of���is unsupported.

Solution: Notify CS Software Support of this message and givethem the sense data.

�������� ���������� �������� ������������� ��������������

Explanation: The buffered log overflowed for device������ataddress�����with volume serial number� ���. The logcounters have been added to the statistics.

Solution: None required.

MPSTWRC57 MPSTWRC60

246 MPST Messages and Codes Manual – Version 2.04

�������� �������������������� ��������������������������������������������� ��

Explanation: The buffered log data is read at the end of eachpass for device�������at address������with volume serialnumber������. The log counters have been added to thestatistics.

Solution: None required.

�������� �������������������������������������� � �������� ������������������������

Explanation: A read buffered log CCW was issued to obtainthe current buffered log for device�������at address������withvolume serial number������. The CCW failed with an SIOcondition code of�����and������of�� � ��.

Solution: None required.

��������� ��������������������������������������������������� �������

Explanation: A unit check was posted due to end of data beingdetected on the cartridge tape. This is an excepted error. Thetype of pass ( ��) is����for a write pass,�����for a readforward pass, or�����for a read backward pass.

Solution: None required.

��������� ���������������������������������� �������������������

Explanation: When a cartridge tape in ICRC format is readbackward by device�������at address������with volume serialnumber������, this message is posted. FSC of X’4411’.

Solution: None required.

MPSTWRC61 MPSTWRC63

247 Chapter 20. MPSTWRC

������ � ��������������������������� �����������������������

Explanation: A pass has been started on test device��� ��ataddress������with volume serial number������. The type ofpass (�� �) is�����for a read forward pass,�����for a readbackward pass, or��� �for a write pass.

Solution: None required.

������ � ������������������������� ����������������������������������������������������������������������������������������� �������� �� ��������������������������������������������������� ����

Explanation: A pass has ended on test device��� ��ataddress������with volume serial number������. The type ofpass (�� �) is�����for a read forward pass,�����for a readbackward pass, or��� �for a write pass.

The start and end date and times, as well as the elapsed time forthis pass, are listed.

Solution: None required.

������ ������������������� ������������������������ ����������� ������������������ ������������������

Explanation: This message always follows message� �����.

Solution: None required.

MPSTWRC64 MPSTWRC97

248 MPST Messages and Codes Manual – Version 2.04

��� #��� !! ��������� ������ ����!�� ��������� ����� %���"������ �������������������� ����$�������

Explanation: A cartridge tape written in 3480–2 XF format ismounted on device������at address������and the device doesnot support 3480–2 XF format.

Solution: None required.

��� #���� ��&������� !������������� ����$������� �����$��!���������&������

Explanation: The���� ��of the actual record is greater thanthe maximum block size specified (����) via the�� ����parameter or the default length if�� �����was not specified.

Solution: None required.

��� #���� ������ ��������������

Explanation: The parameter (���) is either coded incorrectlyor is invalid for the��������command for the�������function.

Solution: Re-enter the��������command using the correctparameter.

��� #���� "����������%��������������#����

Explanation: The��������command����� ��was issued to������. The valid��������commands for��������follow thismessage.

Solution: None required.

��� #���� #���� �������� ��!���� ������%������� ���

Explanation: The������������� ���is not supported by the�������function.

Solution: None required.

MPSTWRC98 MPSTWRC98

249 Chapter 20. MPSTWRC

�������� �������������

Explanation: This message is issued in response to a�������

����������command requesting the current value of���������.

Solution: None required.

250 MPST Messages and Codes Manual – Version 2.04

251 Chapter 21. MPSTWRD

Chapter 21. MPSTWRD

Write-Read Disk (WRDISK) Messages

All MPST functions and diagnostics use standard I/O operationchecking routines and these routines issue standard messages forerrors. Error message numbers are issued according to whichfunction or diagnostic was being run when the error occurred.

Hint: To make finding the messages easier, both the messagenumber and the message text are bold.

The following messages are issued for Write-Read Disk

MPSTWRD00 MPSTWRD02

252 MPST Messages and Codes Manual – Version 2.04

��������� ���������������

Explanation: The�������function will be executed on thedevices listed by message����������.

Solution: None required.

��������� ��������������������

Explanation: The parameter (��) is either coded incorrectlyor is invalid for the�������function.

Solution: Re-enter the command using the correct parameter.

��������� ��������������� ��������������������������������������������������������� �������� ���������

���������������� ����������������� ����������������������� �����

Explanation: �������has successfully configured test device������at address����.

� If the device has the DASD fast write (DFW) feature, then��������will be�����������or����� �����.

� If the device is an Iceberg or Nordique device, then��������will be����and STK and the product name willbe listed.

Solution: None required.

MPSTWRD03 MPSTWRD03

253 Chapter 21. MPSTWRD

��������� ��� ��������������������������������������������������������������

������������������������������� ��� ������������������������� ����� ���������������������������� ������������������������������� ����������������������� ������ �������������������������� ������������������������������� �

�����������������������������������������

Explanation: The summary for this execution of����� ��fordevice�������at address�����with volume serial number������is printed. Each track tested by����� ��was tested anaverage of�� ��times. �� ��is calculated by dividing thenumber of times any track was selected for testing by thenumber of tracks to be tested.

The� �������������table lists the number of recordsprocessed (both reading and writing) and the number of errorsencountered for each head tested. The head number is listed indecimal and hexadecimal.

The� ������������������table lists the number of errorsfor each error type for all heads. ������errors are errors whichare not format 0 through 8. �������errors are errors wheredata read did not match the data written.

Solution: None required.

MPSTWRD04 MPSTWRD08

254 MPST Messages and Codes Manual – Version 2.04

��������� ������������ ������

Explanation: No test devices were configured for thisexecution of��� ���.

Solution: Verify that the test devices are correctly defined andonline and available.

��������� ����������� �������������������������������������������������� ��������

Explanation: The block size specified by the��������parameter is larger than the maximum allowed for test device�����. The block size will be set to the maximum allowed forthis device.

Solution: None required

��������� ������������������������� ������ ���������

Explanation: An error occurred on device�������at address�����with volume serial number������and the� ���parameter was specified. A dump of the track follows thismessage.

Solution: None required.

��������� ��������������������� ��������������

Explanation: Device�������was not configured. ������for not configuring:

� �������������������������—A 3390 controller witha 3390 device attached and the device characteristicinformation indicates that the problem is that the F5 factor,a division for the formula, is zero.

� ��� ��������������������—The test device DDcard for�������is not a type 2, 3 or 4 DD card. Verify thatthe DD card is coded correctly.

MPSTWRD08 MPSTWRD08

255 Chapter 21. MPSTWRD

� �����������������������������—A read devicecharacteristics command was issued to the device and anerror was encountered.

� ����������������—A sense command was issued to thedevice and an error was encountered.

� ���������������—A sense �� command was issued tothe device and an error was encountered.

� �����������������������������—A sense subsystemstatus command was issued to the device and an error wasencountered.

� �������������������������—More systemmemory required for������ �to run with this manydevices.

� ������������������������—There is no DD card for�����. Verify that the DD card is coded correctly.

� ������� �����������—The DD card specified for testdevice�������is a DD type 1 (zero space allocated). TheDD type must be 2, 3 or 4.

� ����������—An open for the device failed. Verify thatthe DD card is coded correctly.

� ������������������������������—The device typespecified on the������ �DD card does not match thedevice type obtained from the read device characteristicscommand.

� ��������������������—The test device DD card for������does not define a DASD device. Verify that theDD card is coded correctly.

Solution: None required.

MPSTWRD09 MPSTWRD13

256 MPST Messages and Codes Manual – Version 2.04

��������� ���������� ������������� ���

Explanation: The�����parameter or��������command wasspecified and too many devices were requested.

Solution: The maximum number of defined devices is eight.

��������� ���������������������������������

Explanation: The I/O limit specified by the��������parameter has been reached for device� ����at address�����with volume serial number�����. Testing has terminated onthat device but continues on any other devices.

Solution: None required.

��������� ����������������������������������������������

Explanation: ������has detected that a�����command wasentered at the operator’s console. Testing on all devices,including� ����at address������with volume serial number����, has been stopped.

Solution: None required.

��������� ��������������������������������������������������������

Explanation: Testing on test device� ����at address�����with volume serial number������has been terminated. Eitherthe number of permanent errors exceeds the maximum allowedby the��������parameter or an unrecoverable I/O error hasoccurred.

Solution: None required. Testing continues on all otherdevices.

MPSTWRD15 MPSTWRD18

257 Chapter 21. MPSTWRD

�������� ������������������������������������

Explanation: No errors were detected by��������while testingthe device at address������with volume serial number�������.

Solution: None required.

�������� ������������������������������������������

Explanation: Correctable/temporary errors were detected by�������while testing the device at address������with volumeserial number�������. This message does not indicate aproblem that requires immediate attention.

Solution: This message indicates problems that should beinvestigated at the next scheduled maintenance period. TheMPST printer output should be retained and given to CSSoftware Support.

�������� �����������������������������������������������������������������������

Explanation: Errors were detected by��������while testingthe device at address������with volume serial number�������.

Solution: This message indicates problems that should beinvestigated as soon as possible. The printer output should beretained and given to CS Software Support.

�������� ����������������������������������� �������������������

Explanation: Correctable data checks were detected by�������while testing the device at address������with volumeserial number�������.

Solution: This message indicates problems that should beinvestigated at the next scheduled maintenance period. TheMPST printer output should be retained and given to CSSoftware Support.

MPSTWRD19 MPSTWRD33

258 MPST Messages and Codes Manual – Version 2.04

��������� ��������������������������� ���� � �� �

Explanation: ������detected no problems while testing thedevice at address������with volume serial number�����.

Solution: None required.

��������� �������������������� ������� ����� �������������

Explanation: An error occurred while trying to fill the trackwith records. This error prevents further testing on the track andtesting on this track is terminated. However, this track may beselected for testing again.

This track is located on device�������at address������andvolume serial number�����.

Solution: None required.

��������� ���� ��������

Explanation: An error occurred while attempting to write awrite count, key, or data record.

Solution: None required.

��������� ���� �������

Explanation: An error occurred while attempting to read awrite count, key, or data record.

Solution: None required.

��������� ���� �������

Explanation: An error occurred while attempting to update arecord with a write key and data command.

Solution: None required.

MPSTWRD34 MPSTWRD80

259 Chapter 21. MPSTWRD

������ �� ������������

Explanation: An error occurred while attempting to read anupdated record.

Solution: None required.

������ �� ������������

Explanation: An unrecoverable error occurred. Anunrecoverable error is a channel error, intervention required,command reject, or a device error other than unit check.

Solution: None required.

������ � �����������������������������������

Explanation: An error occurred on test device�����ataddress�����with volume serial number������and themaximum number of retries specified by the������parameterhas been reached without retry being successful.

Solution: None required.

������ � �� �������������������������������������������� �����

Explanation: Bad parameter passed in program.

Solution: The MPST printer output should be retained andgiven to CS Software Support.

������ � ����������������������� ����� ��

Explanation: Either the parameters�������or�������included device�����and that device does not support theDASD fast write (DFW) feature.

Solution: Enter the correct parameter.

MPSTWRD81 MPSTWRD85

260 MPST Messages and Codes Manual – Version 2.04

��������� ��������������������������� �����������

Explanation: Device������is not connected to a 3390 typecontroller with the cache feature.

Solution: None required.

��������� ��������������������������������� �������

Explanation: Device������at address������with volumeserial number�������had a failure issuing DFW commands.

Solution: None required.

��������� ������������ �����������

Explanation: The DASD fast write (DFW)����of thedevice at address������is now either�������or��������.

Solution: None required.

��������� ������������ �� �����������

Explanation: Either the sense subsystem status commandfailed or a��� ����parameter was issued to device������andits DFW����failed to�������.

Solution: None required.

��������� ������������ ���������������

Explanation: The 3390 type control for device������does notsupport the DASD fast write (DFW) feature.

Solution: None required.

MPSTWRD86 MPSTWRD97

261 Chapter 21. MPSTWRD

�������� �� ��������������

Explanation: On a 3390 type control for device������the ��������is either:

� ���� �� ��������, or

� ��� �����������.

NVS stands for nonvolatile storage.

Solution: None required.

�������� ����������������������

Explanation: The parameter (����) is either coded incorrectlyor is invalid for the��������command for the�����function.

Solution: Re-enter the command using the correct parameter.

�������� ��� ��� ���������������� ��

Explanation: The��������command��������was issued to����. The valid��������commands for������follow thismessage.

Solution: None required.

�������� �� ��������������������� ������������������

Explanation: The�����������������is not supported by the�����function.

Solution: None required

262 MPST Messages and Codes Manual – Version 2.04

263 Chapter 22. MSAE

Chapter 22. MSAE

MPST Stand-Alone Executive (MPSTSAE) Messages

All MPST functions and diagnostics use standard I/O operationchecking routines and these routines issue standard messages forerrors. Error message numbers are issued according to whichfunction or diagnostic was being run when the error occurred.

Hint: To make finding the messages easier, both the messagenumber and the message text are bold.

The following messages are issued for the MPST Stand-aloneExecutive:

MSAE000 MSAE004

264 MPST Messages and Codes Manual – Version 2.04

������� ���������� ��������� �����

Explanation: This message, including copyright notice, isissued when MPSTSAE successfully loads.

Solution: None required.

������� ������������������������� ������������ ��������������������������������� ������������������������������������������������������������������������

Explanation: MPSTSAE has loaded and is ready to processcommands.

Solution: Enter MPSTSAE commands.

������� ������������������������������������� ����

Explanation: MPSTSAE is executing on a VM virtualmachine.

Solution: None required.

������� �������������������������������������� ������

Explanation: MPSTSAE is executing on an AP/MP system.The number of processors configured is ���.

Solution: None required.

������ ��������������������� �� ����

Explanation: MPSTSAE is unable to determine the one secondBCT instruction count for the CPU. Time dependent testingcannot be performed.

Solution: None required.

MSAE005 MSAE009

265 Chapter 22. MSAE

������ �� �����������������������������

Explanation: The CPU time-of-day clock is either incorrect ornot working.

Solution: To continue, reset the time-of-day clock.

������ �������� �������������������������������

Explanation: The time-of-day (TOD) clock must be enabled tocontinue MPSTSAE operation.

Solution: Press the switch on the CPU that enables the TODclock.

������ �������������������������

Explanation: The CPU interval timer is not operational.

Solution: None required.

������ �������������������������������������������

Explanation: The interval timer must be enabled.

Solution: Enable the interval timer; then, enter any keyboardcharacter to continue MPSTSAE operation.

����� �������� ��� ���������������������

Explanation: The storage areas being used by MPSTSAE are:

� �������� �—The size of the main storage area.

� ����������—The size of the MPST dynamic area.

� ���������—The high address used by MPST SAE.

Solution: None required.

MSAE010 MSAE017

266 MPST Messages and Codes Manual – Version 2.04

������� ������������������

Explanation: MPSTSAE is operating in XA, ESA or 370mode.

Solution: None required.

������� ���������� ����

Explanation: The MPSTSAE task, �� ����, has abended.This message displays if the������������command is used tohalt operation. If a printer is currently defined, a dump of themain storage area is printed.

Solution: If this message is displayed and a�����������

command was not issued, contact CS Software Support. Aprogram error has occurred.

������� ���������������������������������� ������ ����������� ����������������� �����������

Explanation: An I/O error has occurred.

� ����—The CPU number.

� ���������—The device address.

� �����—The ECB completion code.

� � ��—The SIO condition code.

� ��� ��������—The CSW unit and channel status andresidual byte count.

� ��� ����������������—The cylinder and headaddress and the record number (if DASD).

� ����������—The sense data (if unit check is � in theunit status).

Solution: None required.

MSAE018 MSAE019

267 Chapter 22. MSAE

����� ������������������������������

Explanation: An I/O error occurred when MPSTSAEattempted a NOP command to a device. The message precedingthis one (�������) describes the error.

Solution: Reply to the message, enter one of the following:

� ��to ignore the message and continue.

� ��to retry the operation.

� ��to cancel the function attempting to use the device.

����� ����������� ������

Explanation: The program being run attempted to����anundefined DD card� ���.

Solution: Check the current device definition or the����

control card.

MSAE020 MSAE020

268 MPST Messages and Codes Manual – Version 2.04

������ ���������������������������������������������� � ����� ���������������� � ����� ���������������� � ����� ���������������� � �����

������������������ � ����� ������������������� � ����� ��� �� ������������� � ����� ���������������� � ����� �������������� � ����� ��� �� �������� � ����� ���������������� � ����� �������������� � ����� ��� �� �������� � ����� ���������������� � ����

�������������� ������� � ���

����������������� � ���

���������������� � ���

Explanation: If more than 10 I/O operations are performed ona test device, this message is issued (only to the console) whenthe function ends and the test device is closed.

� Operation time—The time between a request for an I/Ooperation (EXCP) and when the operation is posted ascompleted (ECB).

� Queue time—The time an I/O operation remains queuedby the I/O supervisor due to a channel, control unit, ordevice busy condition.

� CCW time—The time between the last SIO, SIOF, orSSCH instruction to when the channel is received for theCCW chain. When MPSTSAE is run on a VM/370 virtualmachine, the VM control program (CP) is included in theCCW values.

Solution: None required.

MSAE095 MSAE099

269 Chapter 22. MSAE

������� ���������������� ��������������������

Explanation: A buffer log overflow occurred on the IPL/loaddevice.

Solution: None required.

������� ���������������������������������������������������������������������������

Explanation: An error occurred on the MPSTSAE IPL device.

� ��������—The device address.

� �����—The ECB completion code.

� ���—The SIO condition code.

� ������������—The CSW unit and channel status andresidual byte count.

� ������������������—The cylinder and headaddress and the record number (if DASD).

� ����������—The sense data (if unit check is �� in theunit status).

Solution: None required.

������� �� �����������

Explanation: The program module cannot be found on the IPLdevice.

Solution: Contact CS Software Support.

MSAE109 MSAE111

270 MPST Messages and Codes Manual – Version 2.04

�� ��� ��� ���� ��� � � �� ��� � � �� ����� � � �� ������� � � �� ��

Explanation: During program load MPSTSAE could notresolve references (1–7).

Solution: Contact CS Software Support.

�� ��� ������� ����� �� ����������� ��� ������� �� ������

Explanation: The test device at address������on CPU����has reported environmental sense data. This data could bestatistical or logging mode data.

� �������—The CPU number.

� � ��� �����—The device address.

� � �� �����—The sense data (if unit check is �� in theunit status).

Solution: None required.

�� ��� ��������������� ��� ������������������� �� ������

Explanation: An unexpected I/O interrupt was received fromthe test device at address������on CPU����.

� �������—The CPU number.

� � ��� �����—The device address.

� ����������—CSW unit and channel status.

� � �� �����—The sense data (if unit check is �� in theunit status).

Solution: None required.

MSAE112 MSAE115

271 Chapter 22. MSAE

�� ��� �������� � �������������������� ��� ������������������ ���������� �������

Explanation: A buffered log full status was received from the4305 test device at address����on CPU����. Each of theeight 8–byte buffered log entries are printed.

� �������—The CPU number.

� � ��� ���—The device address.

� ����������—CSW unit and channel status.

� �������—The eight 8–byte buffered log entries.

Solution: None required.

�� ��� ����� ��� ���������������� ����������

Explanation: A recoverable machine check interrupt wasreceived from CPU ��� and ignored by MPSTSAE. Bits 0–64of the machine interrupt code from main storage address hex E8are printed.

Solution: None required.

�� ��� �� ����������������� �����

Explanation: An external interrupt from CPU�����wasreceived and ignored by MPSTSAE. ���� is the externalinterrupt code from main storage address hex 86.

Solution: None required.

�� ��� ��� �� ������� ���� ������������� ��� ����� �� �����

Explanation: The test device at address����on CPU����� isnot ready. ��� is the sense data (if unit check is �� in the unitstatus).

Solution: None required.

MSAE116 MSAE117

272 MPST Messages and Codes Manual – Version 2.04

������ �������������������������������������

Explanation: An unexpected status was received when an ISOwas done to the test device at address������on CPU���. ��is the unit and channel status bytes of the stored CSW.

Solution: None required.

������ ����� �����������������������������������

Explanation: The test device at address������on CPU���has failed to present device end, control unit end, or channel endstatus within the MPSTSAE timeout period. For tape devicesthe timeout period is 2 minutes; for all other devices the timeoutperiod is 1 minute.

��� is the last status received by MPSTSAE for the testdevice. ��� could be:

� ����—Device busy (CC=1 with BUSY) on the last SIO.

� �� —An I/O operation was started and channel end and/ordevice end status was not received.

� ����—Channel busy (CC=2) on the last SIO.

� ����—Control unit busy (CC=1 with STM and BUSY) onthe last SIO.

� ����—No I/O operation is in progress or pending.

� ��—The device is not ready.

Solution: None required.

MSAE118 MSAE119

273 Chapter 22. MSAE

������ �������������������������� �

Explanation: The MPSTSAE missing interrupt handler hasgenerated a pseudo I/O interrupt for a hung I/O operation. Thepseudo I/O interrupt has both the interface control check and thechannel control check set in the channel status byte of thechannel status word (CSW).

Solution: Message���������describes the hung I/O operation.

������ �������� ������������

Explanation: An unknown message has been queued.

Solution: Contact CS Software Support.

MSAE120 MSAE120

274 MPST Messages and Codes Manual – Version 2.04

������ �������������������� �������������������������������������������������������������������������������������������������������������������������������������� ����������������� �������������� ������������� �������������������������������������������������� ������������������������������ ��������������� ��������

Explanation: A SIM record was logged from the test device ataddress�����.

� ����������—The device address.

� ���������������—The date and time of the SIM.

� �������������

� ����������—The device code.

� �������������������—The device type and modelnumber.

� ������������������—The controller type and modelnumber.

� ��������—The error code.

� �������������������������������—The severitycode, SIM type, and the SIM repeat.

� � ����������������� ���—The manufacturer’s idand the plant id.

� ��������� �—The serial number for the plant.

� ��������—The SIM id.

� �� �����������������—The reference codes.

� ������������—The message code.

� �������� ���������������—The message modifiers.

� ������ �����������—The raw sense bytes.

Solution: None required.

MSAE161 MSAE171

275 Chapter 22. MSAE

������� ����������������������

Explanation: The SYSIN device being configured has nophysical paths enabled.

Solution: Enable a path to the device and reissue the������command.

������� �������������������������������

Explanation: The�������command just issued has completed.

� If the SYSIN device is successfully accessed, the��������

is the device address and the device type. If this is a tapedevice, �� is the file number.

� If the SYSIN device has been varied offline, the �������

is��������.

Solution: None required.

������� ��������������������������������� ��������

Explanation: A SYSIN device was already defined. The������command just issued was ignored

Solution: None required.

������� �������������������������������������

Explanation: Because MPST was running when the������

command was issued, the command was ignored.

Solution: None required.

������� ��� ���������������

Explanation: The status of the start I/O fast option isdisplayed.

Solution: None required.

MSAE172 MSAE211

276 MPST Messages and Codes Manual – Version 2.04

������� ������������������

Explanation: The current state of the missing interrupt handleris displayed in response to an�����command.

Solution: None required.

������� �������������������������������

Explanation: This message is issued in response to a�����

command.

� If block multiplexing is enabled, control register��������

is set to��.

� If block multiplexing is disabled, control register �������

is set to��.

Solution: None required.

������� ���������� ��������

Explanation: The�������command was issued and������

status is displayed.

Solution: None required.

������� �������������������������������������

Explanation: Because MPST was running when the� ����

command was issued, the command was ignored.

Solution: None required.

������� �����������������������������������

Explanation: Because MPST was running when the� ��

command was issued, the command was ignored.

Solution: None required.

MSAE221 MSAE225

277 Chapter 22. MSAE

������� ����������������������

Explanation: The LMU(2) is not online.

Solution: Correct the problem and reissue the����[�]command.

������� �������������������������������

Explanation: The���[�] command just issued has completed.

� If the LMU(2) device is successfully accessed, the������� is the device address and the device type.

� If the LMU(2) device has been varied offline, the �������

is���������.

Solution: None required.

������� ��������������������������������� ����

Explanation: An LMU(2) device was already defined. The��[�] command just issued was ignored

Solution: Enter an����[�]�� �command and then an����[�]�����command to change the LMU(2) devices.

������� �������������������������������������

Explanation: Because MPST was running when the���[�]command was issued, the command was ignored.

Solution: None required.

������� ����� ��������������������������������

Explanation: Because MPST was running when the�������

command was issued, the command was ignored.

Solution: None required.

MSAE226 MSAE232

278 MPST Messages and Codes Manual – Version 2.04

������� ����� ������������������������������ ������

Explanation: A��������command was issued but no printeris configured.

Solution: Enter the������command to assign a printer; then,reissue the������ �command.

������� ����� ���������������������� �����������

Explanation: A��������command was previously issued buthas not yet continued processing. The second�������

command is ignored

Solution: None required.

������� ����� �������������������������������������

Explanation: A��������command was issued, but the printdevice assigned (using the�����command) is not valid. To use�������the printer type must be a 1403, 3203, or a 3211.

Solution: Enter the������command to assign a printer; then,reissue the������ �command.

������� ����������������������������������������

Explanation: A� ����command was issued while MPST wasnot running and the command was ignored.

Solution: None required.

������� ���������������

Explanation: A� ����command was issued and MPSTterminates as soon as the command is detected. The exact timethat MPST terminates depends upon the function currentlyexecuting.

Solution: None required.

MSAE233 MSAE236

279 Chapter 22. MSAE

������ ������������ ����������� ���� ��

Explanation: A second������command was issued whileMPST was running and the command was ignored.

Solution: None required.

������ �� ���������� �������� �� ���������� ��

Explanation: A�������command was entered and the mainprogram was not running.

Solution: None required.

������ �� �������� ��

Explanation: A�������command is pending and awaitsprocessing by the main program.

Solution: None required.

������ �� ���������� �������� ��� ���� ��

Explanation: A�������command was entered and theprevious command is still pending.

Solution: Re-enter the�������command.

MSAE237 MSAE245

280 MPST Messages and Codes Manual – Version 2.04

�� ��� ����������� ���������������������������

Explanation: A��� ����command was entered and the mainprogram is stopping.

Solution: None required.

�� ���� � ��������� �������������������������������

Explanation: A�������command was issued while MPSTwas not running and the command was ignored.

Solution: None required.

�� ���� ������ ����������� ����� � ����������

Explanation: MPST was cancelled by either a������

command or by an MPSTSAE abend processing

Solution: None required.

�� ��� ������������������������������������������

Explanation: This message is issued in response to a�������

����command.

� ��������—The binary device number assigned to thesubchannel.

� �����������—The subchannel id (SID).

� ��������������������—The channel path identifiersdefined for this subchannel.

Solution: None required.

MSAE246 MSAE252

281 Chapter 22. MSAE

�� ��� ��������������

Explanation: This message is issued in response to a�������

����command. ����is the subchannel identification and�����

is the condition code for the store subchannel (STSCH)instruction. If the code is��, the subchannel information blockis displayed following this message.

Solution: None required.

�� ��� �������������� ������

Explanation: This message is issued in response to a�������

���command.

� �������—The binary device number assigned to thesubchannel.

� ���� ������—The subchannel id (SID).

Solution: None required.

�� ��� ���������������� ������������������

Explanation: A��� ��printer�������command was issuedwhile MPST was running and the command was ignored.MPST cannot be running when the��� ��command is issued.

Solution: Stop MPST operation and reissue the����command.

�� ��� ���������������� �������� ������ ��� �����

Explanation: A��� ��printer���command was entered butthe printer was already defined.

Solution: None required.

MSAE253 MSAE255

282 MPST Messages and Codes Manual – Version 2.04

������� �������������� ������� ������ ������������������������������������

Explanation: An I/O error has occurred during printerdefinition.

� �� ������—The device address.

� �����—The ECB completion code.

� ���—The SIO condition code.

� ��������—The CSW unit and channel status andresidual byte count.

� ���������—The sense data (if unit check is �� in theunit status).

Solution: None required.

������� �� ����������� ��

Explanation: While attempting to verify that the printer devicewas operational, an I/O error occurred. The������printer���command fails.

Solution: None required.

������� �� ������� ��������� ��

Explanation: The printer device is offline (SIO conditioncode=3).

Solution: Correct the problem and reissue the������command.

MSAE256 MSAE259

283 Chapter 22. MSAE

������� ����� ������� ������������������������������������������ ������������������������������������� ���������������

Explanation: The last��� �command was successfullyprocessed.

� If the print device is successfully accessed, the ������� isthe device address and the device type.

� If the print device was varied offline, the ������� is ����.

Solution: None required.

������� ���� ���������������������������� ���������

Explanation: A�����command was issued but no printer isconfigured.

Solution: Use the������command to assign a printer; then,reissue the�����command.

������� ������������

Explanation: The entry, specified in the�����command, hasbeen logged on the printer.

Solution: None required.

������ ����� �������������� ��������

Explanation: This message is issued in response to a�������command.

Solution: None required.

MSAE260 MSAE263

284 MPST Messages and Codes Manual – Version 2.04

������ �����������������������������������������������

Explanation: A��� �����command was issued but no printeris configured.

Solution: Use the���� �command to assign a printer; then,reissue the����������command.

������ �����������������������

Explanation: This message is issued in response to a�������

��command. The current Julian date and the time is displayed.

Solution: None required.

����� ��������������������������������������������

Explanation: This message is issued in response to a�������

��command when MPST is not running. The current Julian dateand the time is displayed.

Solution: None required.

����� ���������������������������������������� �������������������������������������������������������� ������� ����� � ��������������� ���������� ������ ������� �� ����

���

�������� ���������� ������ ������� �� ����

Explanation: This message is issued either in response to a���������command or as a result of a����������command.MPST is currently running and the current state of any testdevices opened by MPST is shown.

� ���� ����—The device address.

� ������ ��� ��—The volume serial number.

� ��� �—The number of I/O operations completed on thedevice.

MSAE264 MSAE264

285 Chapter 22. MSAE

� � � ��—The number of SIO, SIOF, or SSCH instructionsdone to the device.

� � ����� ������—The number of SIO or SIOFinstructions that received channel busy.

� � ����� �����—The number of SIO or SIOFinstructions that received control unit busy.

� � ����� �������—The number of SIO or SIOFinstructions that received device busy.

� ������ ���—��� is the last status received byMPSTSAE for the test device. ��� could be:

� �� �—Device busy (CC=1 with BUSY) on the lastSIO.

� ���—An I/O operation was started and channel endand/or device end status was not received.

� ����—Channel busy (CC=2) on the last SIO.

� ����—Control unit busy (CC=1 with STM andBUSY) on the last SIO.

� ���—No I/O operation is in progress or pending.

� ���—The device is not ready.

Solution: None required.

������ ����� ���������������� �����

Explanation: This message is issued in response to a��� ���

��command. If any reply messages are outstanding, the replyID number and the text of the message are displayed.

Solution: None required.

MSAE265 MSAE268

286 MPST Messages and Codes Manual – Version 2.04

������ �������������

Explanation: A�������command was issued and the devicewas not available. The��������the device was not available:

� ��� �

� ���������������

� ��������

� �����

Solution: None required.

������ ��������������

Explanation: A���� (write tape mark) command was issuedand the device was not available. The��������the device wasnot available:

� ��� �

� ���������������

� ��������

� �����

Solution: None required.

������ ��������� ����������

Explanation: Display monitor has started.

Solution: None required.

������ ��������� ���� ��

Explanation: Display monitor has stopped.

Solution: None required.

MSAE269 MSAE272

287 Chapter 22. MSAE

������ �����������������������������������

Explanation: A��� �����command, specifying anMPSTSAE device, was issued. ��� �����does not traceMPSTSAE devices and the command is ignored.

Solution: None required.

������ ������������������������������������ ����

Explanation: The��� �����command was issued to anundefined device. ��� �����will begin tracing all I/O to thisdevice once it has been defined.

Solution: None required.

������ ��������

Explanation: This message is issued in response to anMPSTSAE����command.

Solution: None required.

������ �������������������������������������������

Explanation: This message is issued in response to a�������

��command.

� ��������—The CSECT name.

� ����—The offset into the CSECT.

� ���—The verify or replace data.

Solution: None required.

MSAE274 MSAE275

288 MPST Messages and Codes Manual – Version 2.04

����� ���������������������������������

Explanation: The message issued as part of the “MAP DATA”storage display. �����is the address of the main storage data,�������� is the data in hex, and ���� is the data in a printableformat.

Solution: None required.

����� ����������������

Explanation: This message is issued in response to a�������

��command when no devices are defined.

Solution: None required.

MSAE276 MSAE281

289 Chapter 22. MSAE

�� ��� � ��� �� ������������� ����� ���� ������ ����� ������ ���� ������ ����������� ������������������������������

�������������� ����������� ��������������������������

Explanation: This message is issued in response to a�������

�command. The current test device definitions are listed.

� ��—The DD name for this device definition.

� �����—The processor and device address.

� ����� �—The device type.

� ����—The DD card type.

� �����—The volume serial number of the DASD or tapevolume mounted on the device.

� ������������—The 1–44 character data set name or*NONE*.

� ���������—The first track of the test data set, if DASD,specified as cccc.hhhh (c=cylinder, h=head).

� �������—The last track of the test data set, if DASD,specified as cccc.hhhh (c=cylinder, h=head).

� �������—The number of tracks in the test data set.

Solution: None required.

�� �� ������������������ �� ��� �������� ��

Explanation: An invalid command (��) was entered and thecommand was ignored.

Solution: None required.

MSAE282 MSAE291

290 MPST Messages and Codes Manual – Version 2.04

������ ����������� ��������������

Explanation: This message is issued when a�����commandwas entered without a selection parameter. The menu for����

follows the first line of this message. This message is followedby message�������.

Solution: None required.

������ ����������������������������������

Explanation: This message is issued when a�����commandwas entered without a selection parameter. This message ispreceded by message�������.

Solution: Refer to message��������and enter the desired helpselection or��� �to terminate the�����command.

������ ������������������

Explanation: The help selection, chosen when responding tomessage�������, follows this message.

Solution: None required.

����� ����������� ������� �������������� ���������������������� ���������������

Explanation: A previous�����command is still beingprocessed. The�����command just issued was ignored

Solution: Enter the� ���������command to display theoutstanding Help selection reply messages.

������ ��������������������� ���������������������

Explanation: An invalid parameter (����) was entered or arequired parameter was omitted and the entire command wasignored.

Solution: Enter������and correct the problem.

MSAE292 MSAE295

291 Chapter 22. MSAE

����� �� ������� ������� ��� ������������������������

Explanation: A������command was issued but device�����

has not been configured and the command is ignored.

Solution: None required.

����� ������������������������ ���� ����������

Explanation: A������command was issued but nointervention required condition exists for device������and thecommand is ignored.

Solution: None required.

����� �������� ������ ����� ����������

Explanation: In response to a������command device endwas posted for device�����.

Solution: None required.

����� �������������������������� ��������� ���������������� ������� ����������� ������������������������������

Explanation: This message is issued in response to a�������

��command. An entry for each configured CPU is shown.

� ���—The number of the CPUs.

� ����� ���—The one second BCT count in hex.

� ���—The CPU address in hex.

� �����—The CPU id data.

� ���—The internal MPSTSAE flags.

� �������—The address of the prefix storage area (PSA) forthe CPU.

Solution: None required.

MSAE296 MSAE302

292 MPST Messages and Codes Manual – Version 2.04

�� �� �������������� ���� ����� �� ��������

Explanation: A command to assign a device (��� , ���, etc.)was entered and that device address is already in use.

Solution: If possible, assign a different address to the device.

�� �� ��������� ���� ����������������� ���� �� ������������������������ ���������������� ��� ������

Explanation: This message is issued in response to a������

�command.

� �������—The size of the CPU real memory.

� � �������—The area MPST uses.

� ����� and �����—The boundaries of the data area (D/A)MPST uses.

� —The fixed task.

� �� ������—The size of each fixed task area.

Solution: None required.

�� � ���� �������� ���

Explanation: This message displays the return code from the���command entered while running VM/370.

Solution: None required.

�� ��� ���� ��� �� ���������

Explanation: If no devices were defined, this message is issuedduring the device definition phase of����commandprocessing

Solution: None required.

MSAE303 MSAE303

293 Chapter 22. MSAE

����� ������������������ ������������������������������������ ��������� ��������������������� ���������������

���������������������������� ���� ��������� ����� ��

Explanation: This message is issued during the devicedefinition phase of the�������command The current test devicedefinitions are listed.

� ���—The DD name for this device.

� ����� —The processor and device address.

� �������—The IBM device type.

� �—The DD card type (0–6).

� ����� —The volume serial number of the DASD or tapevolume mounted on the device.

� �����������—The 1–44 character data set name or*NONE*.

� �� ���� �—The first track of the test data set, if DASD,specified as cccc.hhhh (c=cylinder, h=head).

� ������ �—The last track of the test data set, if DASD,specified as cccc.hhhh (c=cylinder, h=head).

� ��� ��—The number of tracks in the test data set.

Solution: None required.

MSAE304 MSAE305

294 MPST Messages and Codes Manual – Version 2.04

������ � ������������������������������������

Explanation: This message follows either message�������

or�������.

Solution: Reply to the message, enter one of the following:

� �to edit (delete or add) existing test device definitions.

� ��to prompt the operator for each new entry.

� ��to delete all current device definitions and enter newdefinitions.

� ��to use the current device definitions.

������ ���������������������������������������������

Explanation: This message displays the format in which a testdevice definition is entered.

� �����—the DD name for this device (UUT01 – UUT08).

� �����—the channel path id ( �) and the device address(����). The CHPID is optional.

� ������ —the IBM device type.

� ����� —the device definition type (0–6).

Solution: None required.

MSAE306 MSAE311

295 Chapter 22. MSAE

������ �������������� ������������������

Explanation: This message requires a response.

Solution: Reply to the message, enter one of the following:

� Test device definition����.

� ����to terminate the device definition entry.

������ �������� ������������������������������ �������

Explanation: The last test device definition was rejected.

Solution: The message preceding this one explains the reasonfor the rejection.

������ ������������

Explanation: Test device definition�����was accepted byMPSTSAE.

Solution: None required.

������ ������������

Explanation: The last test device definition contained aninvalid DD name.

Solution: Correct the DD name.

������ �����������������

Explanation: The last test device definition contained aninvalid device address.

Solution: The device addresss must be 3 or 4 hexadecimalcharacters and the process address must be 0–3.

MSAE312 MSAE321

296 MPST Messages and Codes Manual – Version 2.04

������ ������������

Explanation: The last test device definition contained aninvalid device type.

Solution: The device type must be a valid IBM device type:2305–2, 3330–1, 3330–11, 3350, 3380, 3420, TAPE, 3480,3490, 3590, 4420, 1403, 3211, 3203, 3800, 4245, 4245, 4248, or��.

������ �����������

Explanation: The last device definition contained an invalidDD type.

Solution: The DD type must be a single digit from 0–6.

������ ���������� ��

Explanation: The last test device definition contained aduplicate DD name from a previously defined DD card ordevice. The DD name cannot be� � ����,� � �,� � ��, � �����, or� � �����.

Solution: None required.

������ ������������������

Explanation: A duplicate device address was specified duringthe device definition phase. The device address cannot be theaddress of MPSTSAE, IPC, console, SYSIN, or print device.

Solution: None required.

������ ����������������������������������� ������

Explanation: A� � ��command was issued for the testdevice during device definition. This information is displayedfor each configured processor of a multi-processor system.

� ������—The CPU number.

� ��������—The device address.

MSAE322 MSAE323

297 Chapter 22. MSAE

� ���—The SIO condition code.

� �����������—CSW unit and channel status.

� �������� �—The sense data (if unit check is �� in theunit status).

Solution: None required.

������� ����������������������������������������

Explanation: MPSTSAE is running on a multi-processorsystem and the CPU address hasn’t been specified for the testdevice definition.

Solution: Respond to the message:

� �, �, �, or � to specify the CPU address.

� ��to request the�����command (message�������).

� �to cancel the device definition.

������� ������������ ���������

Explanation: This message is issued during deviceconfiguration when MPSTSAE is operating in XA mode. Thebinary device number is assigned to SID.

� ��������—The binary device number assigned to thesubchannel.

� � ���������—The subchannel id (SID).

Solution: None required.

MSAE324 MSAE325

298 MPST Messages and Codes Manual – Version 2.04

������ ����������������������������������������������

Explanation: A�����command was issued to device addrduring device configuration. This information is displayed foreach configured CHPID for the device when MPSTSAE isoperating in XA mode.

� ����������—The channel path identifier.

� ��������—The device address.

� ������—The SIO condition code.

� �����������—CSW unit and channel status.

� ��������—The sense data (if unit check is � in theunit status).

Solution: None required.

������ ������������� ����������

Explanation: MPSTSAE is operating in XA mode and theCHPID was not specified for a test device definition.

Solution: Respond to the message, enter one of the following:

� The channel path identifier to be used (it must be one ofthe id’s displayed in message�������).

� � �to specify all defined channel path identifiers for use.

� ��to request the�����command (message�������).

� ��to cancel the device definition.

MSAE331 MSAE333

299 Chapter 22. MSAE

������� �� �������������������������������������������������������� ������������������� ���������������������������

Explanation: The device definition editor is active.

� If you responded���(edit) to message� �����, themessage is “��������������� ...”

� If you responded���(prompt) to message� �����, thebracketed messages are displayed.

Solution: Respond to the message.

� For the message “��������������� ...” respond

� ��to add an additional test device definition to theexisting set of device definitions.

� ���to delete a current test device definition.

� ���to have the default test devices listed.

� ���to terminate the device definition editor.

� For the bracketed messages respond to the individualprompts.

������� ���������

Explanation: The maximum number of device definitions (8)are already defined. No additional test device definitions areallowed.

Solution: Delete one or more existing device definitions beforeadding additional test device definitions.

������� �������� ���� � � ��

Explanation: This message requires a response.

Solution: Enter device definitions.

MSAE334 MSAE338

300 MPST Messages and Codes Manual – Version 2.04

������� ��������������������

Explanation: The test device definition added using the devicedefinition editor was accepted.

Solution: None required.

������� ����������������������������� �������� ���

Explanation: The test device definition being added by thedevice definition editor was rejected.

Solution: The message preceding this one explains the reasonfor the rejection.

������� ���������������������������������

Explanation: This message requires a response.

Solution: Enter the DD name or the device address of the testdevice to be deleted.

������� ���������������������������

Explanation: Either the DD name or the device address enteredin response to message���������is not currently defined. Notest device was deleted.

Solution: None required.

������� �����������������������������������

Explanation: The test device definition (�����, ����) wasdeleted from the currently defined test devices.

Solution: None required.

MSAE339 MSAE342

301 Chapter 22. MSAE

������ �������� ���������������������������������

Explanation: The response to message�� ������was���.

Solution: Respond to the message:

� To select a default DD set, enter the DD set number (00through 10).

� To display all of the default DD sets, enter�����.

� To display the details for a DD set, enter���������. ����is the number of the DD set.

� To terminate default DD set selection, enter����.

������ ��������������������� �������������

Explanation: The response to message�� ������requested DDset����. The DD set was either not found or was empty.

Solution: Select a different DD set.

������ ����������������

���

���

Explanation: The response to message�� ������was�� �.The available DD set numbers are displayed.

Solution: None required.

������ ���������

Explanation: The response to message�� ������was� �����. The details for DD set�����are displayed.

Solution: None required.

MSAE381 MSAE400

302 MPST Messages and Codes Manual – Version 2.04

�� ��� ������ ���� ��� �� ��������

Explanation: Processing has started on the device definitionphase of the MPSTSAE�������command

Solution: None required.

�� ��� ���� ���� ��� �� ��������

Explanation: Processing has ended on the device definitionphase of the MPSTSAE�������command

Solution: None required.

�� ��� ��������� ����������������������

Explanation: MPST execution began on �������� at������ .

Solution: None required.

�� ��� ����� �� ���������������������� �� �������� ���

Explanation: MPST completed execution on �������� at������ with a return code of���.

Solution: None required.

�� ��� ����������� ���� ������� ������ ����

Explanation: The�����������requires����(million) bytesof memory to run.

Solution: Increase the size of the virtual machine to����bytes.

�� ��� � ������������ �������� �

Explanation: Insufficient main storage was available for thetables associated with the processing of type 2 DD cards.

Solution: If you are running MPSTSAE under VM/370,increase the storage size of your virtual machine.

MSAE401 MSAE404

303 Chapter 22. MSAE

�� ��� �������������������������

Explanation: An invalid extent description was found in theDSCB at ������������ while processing a type 2 DD card.MPSTSAE treats this pack as if no free space was available.

� ����—The four digit cylinder address.

� ����—The four digit head address.

� ��—The two digit record address.

Solution: None required.

�� ��� ���� ������ ������ ����������������

Explanation: An I/O error occurred when MPSTSAEattempted to read the volume label of a CKD DASD test device.The volume label is cylinder 0/head 0/record 3. The messagepreceding this one (�������) describes the error.

Solution: Refer to message �������. Enter���to ignore themessage and continue,���to retry the operation, or���to cancelthe function attempting to use the device.

�� ��� ����� �� ���������������������� ����� ���

Explanation: The volume mounted on the CKD DASD devicebeing configured does not contain a volume label record oncylinder 0/head 0/record 3. The label record must have a 4-bytekey field containing ’VOL1’ and an 80-byte data field startingwith ’VOL1’.

Solution: None required.

�� ��� ������������������������������������

Explanation: The volume mounted on the CKD DASD devicebeing configured does not contain a valid VTOC format 4 DSCBon the first record of the VTOC.

Solution: None required.

MSAE405 MSAE409

304 MPST Messages and Codes Manual – Version 2.04

������� �������� ���������������������

Explanation: MPSTSAE has determined that the test data setextent limits are invalid.

Solution: Redefine the starting track and the size of the testdata set to be within valid cylinder and head limits for the testdevice.

������� �����������������

Explanation: An I/O error occurred reading the VTOC.Allocation of the test device fails.

Solution: None required.

������� ����������������!������� ������� ����

Explanation: Zero tracks are allocated for DD types 3, 4, or 6.DD types 3 or 4 must have one or more tracks allocated forMPSTSAE.

Solution: None required.

������ ������������������������������������ ���������

Explanation: Either the type 3, 4, or 6 data set does not exist orthe format 1 data set control block (DSCB) for the data set isinvalid.

Solution: None required.

������ ���� ������������������������������������

Explanation: The volume mounted on the test device musthave a valid VTOC to locate a DD type 3, 4, or 6 data set.

Solution: None required.

MSAE410 MSAE412

305 Chapter 22. MSAE

������� ���������������� �����

Explanation: The CKD DASD volume being configured doesnot have any unallocated tracks. If the volume has a valid labeland VTOC, only DD types 0, 1, 3, 4, and 6 are allowed. If thevolume does not contain a valid label or VTOC, DD types 0, 1,2, 3, 4, and 6 are allowed.

Solution: None required.

������� ������������������������������������������������� ����������

Explanation: If DD type 2 is used, the reply to this messagedetermines the type and amount of space allocated byMPSTSAE to the test data set.

Solution: Reply to the message, enter one of the following:

� ���to allocate one or more full cylinders of space.

� ����to allocate one or more tracks of space.

� ������to allocate one or more specific tracks.

� � ���to have MPSTSAE display a list of the free spaceavailable.

� �����to cancel the device definition in progress.

������� ������������������ �����������

Explanation: This message is issued in response to a���

reply to message��������.

Solution: Enter either the number of cylinders to allocate (� to�����) or����. If there is no VTOC and the reply is����, theentire volume is allocated.

MSAE413 MSAE416

306 MPST Messages and Codes Manual – Version 2.04

������� ��������� ������������

Explanation: This message is issued in response to a���� or�����reply to message�������.

Solution: Enter the number of tracks to allocate (� to ).

������� ���������������������������������

Explanation: This message follows message��������if thereply to message��������was�����.

Solution: Enter the starting cylinder and head number for thespace requested.

������� ��������������������� ���� ��

Explanation: The requested DASD space is not available.

� If the volume mounted on the test device has a validVTOC, message��������is repeated.

� If the volume mounted on the test device does not have avalid VTOC, message��������is issued.

Solution: None required.

������ �����������������������������"�#$����������������������������������������������������������������������"�����"���������������������!���������������������� ��������������"!������������� ���������������"�������"�������������������������������������������������������������������

Explanation: This message requires a response.

Solution: Reply to the message, enter one of the following:

� Enter�"�to force the allocation of the space requested.

� Enter���to cancel the test device definition in progress.

MSAE417 MSAE421

307 Chapter 22. MSAE

������ ������� ����������������� �

Explanation: This message follows message���������if thereply to message���������was�� �and the reply to message��������was��.

Solution: Enter the starting cylinder and head number in hexfor the space requested.

������ ������� ����������� �������

Explanation: This message follows message���������if thereply to message���������was�����and the reply to message��������was��.

Solution: Enter the starting cylinder number in hex for thespace requested.

������� ������������������ ��������������� !��

Explanation: This message is issued in response to a����

reply to message��������.

Solution: Reply to the message, enter one of the following:

� Enter���to list the next 14 extents of free space.

� Enter���to reissue message��������.

������� ����������������������������������������� !��� !�

Explanation: An I/O error occurred when MPSTSAEattempted to read the volume label of a tape test device. Thevolume label, for either IBM or ASCII, is the first record on astandard labeled (SL) tape. The message preceding this one(�������) describes the error.

Solution: Refer to message ������� and reply to �������:

� Enter���to ignore the error and continue.

� Enter���to retry the I/O operation.

� Enter� �to cancel the test device definition in progress.

MSAE422 MSAE425

308 MPST Messages and Codes Manual – Version 2.04

������� ������ ������������������������������

Explanation: Customer data on the test device may bedestroyed. This message precedes message��������.

Solution: Refer to message��������.

������� ����������������������������

Explanation: This message follows message���������andrequires a response.

Solution: Refer to message���������and reply to��������:

� To write on the test device, enter “oktowrite”.

� Any reply other than “oktowrite” cancels the test devicedefinition in progress.

������� �����������������������������������

Explanation: The VTOC of the CKD DASD volume beingconfigured contains errors. DD type 2 is not allowed if theVTOC cannot be read without errors.

Solution: None required.

������� ����������������������������������

Explanation: The VTOC of the CKD DASD volume beingconfigured has indicated that there are no unallocated tracks. Atype 2 DD card is not allowed unless there is at least oneunallocated track.

Solution: None required.

MSAE426 MSAE441

309 Chapter 22. MSAE

������� ���� �������� ������������� �����

Explanation: The VTOC of the CKD DASD volume beingconfigured is being scanned to determine the location andquantity of free space (unallocated tracks) on the volume. Theamount of time the scanning takes is determined by the size ofthe VTOC.

Solution: None required.

������ ���������������������������������������������������

Explanation: The reply to message� �������was incorrect.Message� �������is repeated

Solution: Respond to message� ������.

������� ��������� �� ���� ������� �����������������

Explanation: During configuration a��������������������������command is issued to the device beingconfigured. Either the command failed or the characteristics arelisted.

Solution: If the command failed, check the device.

������� �����������������������������������������������������������or���������������������������� ����� �������������������������

Explanation: MPSTSAE requires the data set name, of apreviously allocated data set, to test.

Solution: Reply to the message, enter one of the following:

� For DD type 3, enter the data set name (which must beginwith ��������������) or �����to accept the default.

� For a DD type 4, enter the data set name (which mustbegin with ���������������� or �����to accept thedefault.

MSAE442 MSAE446

310 MPST Messages and Codes Manual – Version 2.04

�� ��� ���� ������ ������ ����������������

Explanation: This message requires a response.

Solution: Reply to the message, enter one of the following:

� ��to ignore the error and continue.

� ��to retry reading the label.

� ��to cancel the operation in progress.

�� ��� ������������� �������� �����������

Explanation: This message requires a response.

Solution: Reply to the message, enter one of the following:

� ��if the volume does not have a label.

� ��if the volume does have a label.

�� ��� ������������� ���������������������

Explanation: This message requires a response.

Solution: Reply to the message, enter one of the following:

� ��if the volume does not have a VTOC.

� ��if the volume does have a VTOC.

�� ��� ������������������

Explanation: Start and end block numbers are invalid.

Solution: Re-enter start and end numbers.

�� ��� ������������������������� ���� �����

Explanation: The VTOC has an invalid format 5 DSCB (dataset control block) and no free space can be found.

Solution: Use a different DASD device.

MSAE447 MSAE451

311 Chapter 22. MSAE

������ �� � �������������������������

Explanation: A DSN (data set name) was entered and no tracksare allocated.

Solution: Use a different DSN.

������ ������������� ������������ ���������

Explanation: A DSN (data set name) was entered and it waseither not found or bad.

Solution: Use a different DSN.

����� ���������������������������� �����

Explanation: A DD type of 3 or 4 was entered and the DASDdevice does not have a label or a VTOC.

Solution: Use a different DASD device.

������ ���������������������������

Explanation: The free space on a pack is listed for first, last,and number of entries.

Solution: None required.

������ ������ ��������

Explanation: DD type 6 has been allocated. Only read accessis allowed.

Solution: Enter the full data set name of any previouslyallocated data set.

MSAE452 MSAE456

312 MPST Messages and Codes Manual – Version 2.04

������� ������������� ������������������������

Explanation: This message requires a response.

Solution: Reply to the message, enter one of the following:

� The number of blocks.

� ����to specify all available blocks.

� �����to display message�������.

������� ����������������������������������

Explanation: An I/O error occurred when MPSTSAEattempted to read a data set control block (DSCB) on the volumemounted on an FBA DASD test device.

Solution: Reply to the message, enter one of the following:

� ��to ignore the error and continue.

� ��to retry the I/O operation.

� �to cancel the test device definition in progress.

������� ���������������������������

Explanation: The space requested is not available. If there isany space available, message��������will be displayed.

Solution: None required.

������� ��������������� ���������������

Explanation: The space requested is not available and there isno free space.

Solution: Reply to the message, enter one of the following:

� ��to force space allocation.

� ��to not force space allocation. If you enter��, the devicewill not be allocated; choose a different device.

MSAE457 MSAE491

313 Chapter 22. MSAE

������ �� ������� ��������!����

Explanation: An FBA device is being allocated.

Solution: Enter the first block number to allocate.

������ �������������������� ��������"��!������$�%&�����������������������������������������������������������! ��� ����� ��������������� ����������"����������� ������!� ������!��� �� ��������!������� ���������������������������������������������������������

Explanation: If�������and�������are the same volume, thesame space on the same disk volume has been allocated fromtwo different paths and causes overlapping space allocations.

Solution: Reply to the message, enter one of the following:

� $�to not accept the device definition.

� ��to accept the device definition.

������ �"���������������������� ���

Explanation: The same space on the same disk volume hasbeen allocated from two different paths and the device definitionis not accepted.

Solution: Refer to message�������.

������� #������������� $������������������!���� �� � ����"���� �����!�����!� ������������ ������� ����$� ��������"�� !�����������

Explanation: Test device definitions using DD types 0, 2, and5 require the test device to be online only to the system (orVM/370 virtual machine) MPSTSAE is executing on. If the testdevice is online to more than one system, customer data can bedestroyed. Multiple systems could attempt to write/read data atthe same time to the same DASD cylinder and head location orthe same tape volume.

Solution: Reply to message�������.

MSAE492 MSAE492

314 MPST Messages and Codes Manual – Version 2.04

�� ��� ���������� �� ��� ���������� ������������������������������������������������������������������������������ ������������ ��������������� �� ����� ��� ��������� ���������� ������ �������� ��� ������������� ��� ������������� �������� ��� ����� ������������������������������������������������������

Explanation: This message requires a response.

Solution: Reply to the message, enter one of the following:

� ��if the test device being defined is known to be offline toall other systems.

� ��if the test device being defined is known to be online toother systems.

MSAE493 MSAE494

315 Chapter 22. MSAE

������ ������������������������������������������� ���������������������������

Explanation: An I/O error has occurred during MPSTSAE testdevice definition.

� ��������—The device address.

� �����—The ECB completion code.

� �����—The SIO condition code.

� ���������—The CSW unit and channel status andresidual byte count.

� � ����������������—The cylinder and headaddress and the record number (if DASD).

� �������—The sense data (if unit check is � in theunit status)

Solution: None required.

������ ���������������������������������

Explanation: An I/O error occurred when MPSTSAEattempted to read a data set control block (DSCB) on the volumemounted on a CKD DASD test device. The message precedingthis one (������) describes the error.

Solution: Refer to message��������and reply to�������:

� Enter���to ignore the error and continue.

� Enter���to retry the I/O operation.

� Enter���to cancel the test device definition in progress.

MSAE495 MSAE498

316 MPST Messages and Codes Manual – Version 2.04

������ �������������������� ���������������

Explanation: An I/O error occurred when MPSTSAEattempted to do a� � ���command on the test device. Themessage preceding this one (� ����) describes the error.

Solution: Refer to message�� �����and reply to�� ����:

� Enter���to ignore the error and continue.

� Enter���to retry the I/O operation.

� Enter���to cancel the test device definition in progress.

������ �������������������������������

Explanation: An I/O error occurred when MPSTSAEattempted to do a NOP command to the test device. Themessage preceding this one (� ����) describes the error.

Solution: Refer to message�� �����and reply to�� ����:

� Enter���to ignore the error and continue.

� Enter���to retry the I/O operation.

� Enter���to cancel the test device definition in progress.

������ �������������������������������������������

Explanation: This message displays the volser and the VTOClocation.

� ������—The volume serial number.

� ������������—The location (cylinder, head and record)of the volume table of contents for the configured testdevice.

Solution: None required.

MSAE499 MSAE803

317 Chapter 22. MSAE

�� ��� � �� �������������������������������������or� �� ��������������

Explanation: A����������command (XE4) is issued to eachMPSTSAE test device during test device definition. The datareturned by this command is displayed in this message.

� ������—The control unit type.

� �����—The control unit model.

� �������—The device type.

� ������—The device model.

Solution: None required.

�� ��� �������������� ���

Explanation: This message indicates a program error inMPSTSAE or MPST.

Solution: Contact CS Software Support.

�� ��� ��������������� ���

Explanation: This message indicates a program error inMPSTSAE or MPST.

Solution: Contact CS Software Support.

�� ��� ������������� � ��

Explanation: This message indicates a program error inMPSTSAE or MPST.

Solution: Contact CS Software Support.

MSAE804 MSAE807

318 MPST Messages and Codes Manual – Version 2.04

�� ��� � ��� ��������������� ����������

Explanation: MPSTSAE or MPST is attempting to use thedevice at address������and the device is not online.

Solution: Correct the problem and enter on of the following

� ��to retry MPSTSAE or MPST operation.

� ��to cancel MPSTSAE or MPST operation.

�� ��� � ���������������� ����� �

Explanation: There is insufficient storage available to do anI/O to a device.

Solution: Increase the amount of main storage available toMPSTSAE or run MPSTSAE on a larger system.

�� ��� ��������� ���� ���� �

Explanation: An MPSTSAE or MPST function is attemptingto access a tape device. The file number specified is invalid.

Solution: If the tape file number was obtained from anMPSTSAE reply message or an MPST function control card,re-execute the function and specify a valid tape file number.(Normally, tape file numbers range from 1 to 99.)

�� ��� ���� ��������������������

Explanation: An I/O error occurred on UCB��������duringprint configuration.

Solution: The message preceding this one (�������) describesthe error.

Solution: Reply to the message, and enter one of the following:

� ��for retry.

� ��for cancel.

MSAE808 MSAE809

319 Chapter 22. MSAE

������ ��������� ���������

Explanation: A permanent I/O error has occurred and theMPSTSAE or MPST function using the failing device iscancelled. The message preceding this one (������) describesthe error.

Solution: None required.

������ ���������������� ���������������������������������������������������������������

Explanation: An I/O error has occurred.

� ����� �—The CPU number.

� �������—The device address.

� �����—The ECB completion code.

� �����—The SIO condition code.

� �������������—The CSW unit and channel status andresidual byte count.

� ����������������—The cylinder and headaddress and the record number (if DASD).

� ��������—The sense data (if unit check is � in theunit status).

Solution: None required.

MSAE810 MSAE902

320 MPST Messages and Codes Manual – Version 2.04

������� ������������������

Explanation: This message indicates a program error inMPSTSAE or MPST.

Solution: Contact CS Software Support.

������� ����� ��������� � ���

Explanation: This message indicates a program error inMPSTSAE or MPST.

Solution: Contact CS Software Support.

������� ��������� ��������������������������� ���������

Explanation: An incorrect PA or PF key; other than PA1, PA2,PF1, and PF2; was used. The message appears on the input lineof a 3277, 3278, or 3279 console device.

Solution: Use the correct PA or PF key or type an MPSTSAEcommand over this message.

������� ��������� ���������������

Explanation: The screen is full and there are one or moremessages waiting to be displayed. The message appears on theinput line of a 3277, 3278, or 3279 console device.

Solution: Press the PA1/PF1 or the PA2/PF2 key:

� If the PA2 or the PF2 key is used, MPSTSAE clears thescreen and leaves the console in FRAME mode.

� If the PA1 or the PF1 key is used, MPSTSAE clears thescreen, places the console in ROLL mode, and continues.

MSAE903 MSAE905

321 Chapter 22. MSAE

�� ��� � ������������� �������������������

Explanation: The first non-blank character of the lastMPSTSAE command entered was����, and that reply number isnot currently outstanding.

Solution: Enter the����������command to display thecurrent, outstanding reply number.

�� ��� ����������������� �������������� � �����

Explanation: The first non-blank character (����) of the lastMPSTSAE command entered was ignored because theMPSTSAE internal command buffer is full.

Solution: Reissue the rejected command after MPSTSAE hasprocessed the queued commands in the internal buffer.

�� ��� ������������ ���������� �

Explanation: The data entered was more than the maximumline length of 72 bytes.

Solution: Re-enter the data or accept a truncated line.

MSAE940 MSAE940

322 MPST Messages and Codes Manual – Version 2.04

������ ��������������������������������� ��������������������� �������� �������������� ���������� ������������ ������� ���������� ������������ ���������������

������ ���������� ������������ ��������������������������������������

Explanation: A���������command has been specified andthis message displays on an SIO, SIOF, or SSCH.

� � —The device being traced.

� �����—The processor and device address.

� ������—The channel address word (370 mode), or thechannel program address (XA mode).

� ������ �—The address in main storage.

� �� ��—The SIO condition code.

� ���—The channel status word, if condition code 1 wasposted on start.

� ������—The CCW chain and up to 48 bytes of data perCCW.

� ������ �—Any hex data.

� ���������� ������—There were more than 48 bytesof data and only the first 48 bytes are displayed.

Note: Under XA the entire ORB is also displayed.

Solution: None required.

xxxxxxxx

MSAE941 MSAE941

323 Chapter 22. MSAE

������ ����� ��������������������������������������������� �������������������������� �����������������������������������

���

���� �����������������������������������

��������� �����

Explanation: A����������command has been specified. Thismessage is printed because an interrupt has occurred. Under XAthe entire IRB is also displayed.

� ���—The device being traced.

� ������—The processor and device address.

� ���—The channel status word, if condition code 1 wasposted on start.

� ��������—Any hex data.

� ������—The CCW chain and up to 48 bytes of data perCCW.

� ���� ��—The address in main storage.

� Possible��� ��� �are:

� �������������� ���� � �� —The suppressincorrect length (SLI) flag was�� �in this CCW.Since this was not the last CCW in the chain that wasexecuted, it is impossible to determine exactly howmuch data has been transferred.

� ������� ����� �����—There are more than 48bytes of data. Only the first 48 bytes are displayed.

� �������� ���������������—The suppress transfer(skip) flag was�� �in this CCW. No data has beentransferred.

� ���������� �������—Because the residual bytecount (RBC) in the CSW is the same as the bytecount in the CCW no data has been transferred.

Solution: None required.

MSAE942 MSAE952

324 MPST Messages and Codes Manual – Version 2.04

������ �������������������

Explanation: Message��������indicated a unit checkcondition and MPSTSAE issued a sense command to theaddressed device. This ������� displays the sense information.

Solution: None required.

����� ��������������������������������������

Explanation: The print queue is full and at least one messagehas been lost, but no MPST output is lost.

Solution: The probable cause of this problem is the printer. Ifpossible, correct the problem.

����� ������������������� �

Explanation: An invalid device type is configured as theprinter device.

Solution: Contact CS Software Support.

����� ������������ ���� ������ ������� ����� ���� �����������������������

Explanation: An I/O error has occurred on the printer device.

� ���� �—The CPU number.

� ���� �����—The printer device address.

� � ����—The ECB completion code.

� ���—The SIO condition code.

� ������������—The CSW unit and channel status andresidual byte count.

� ����������—The sense data (if unit check is �� in theunit status).

Solution: None required.

MSAE953 MSAE954

325 Chapter 22. MSAE

������� ����������������������������� ��������������������������������������

Explanation: An unrecoverable I/O error has occurred on theMPSTSAE printer output device. The MPSTSAE print task hasturned����parallel print to route all output messages to theconsole device. The message preceding this one ( �����)describes the error.

Solution: To restart hard copy printing, correct the problemwith the printer output device or use another printer.

Note: The printer output device cannot be varied on more thanonce. Vary the printer output device offline and then vary theprinter (back) online.

������� ����� � ������������������������������������

������������������������

�������������������������

Explanation: A��������command was issued. This messageprints the UCS loaded (���) and tests the ability of the printeroutput device to skip to the top of the form and to space properlyfor single, double, and triple space.

Solution: None required.

xxxxxxxx

MSAE955 MSAE956

326 MPST Messages and Codes Manual – Version 2.04

�� ��� ������������������ � ������������ ������������ ��� �������������

Explanation: A��������command was processed.

� For 1403 printers, the UCS name loaded replaces�����

and the third line is not printed.

� For 3211/3203 printers, this message is issued in responseto either:

� �������with no parameters (used to display currentbuffer contents), or

� �������loading the values displayed into thebuffers.

Solution: None required.

�� ��� ������� ������������ � ����

Explanation: A��������command was processed for a 6100printer output device. The command sequence����

� ��� ������������ ��� �was issued and completedsuccessfully. The default WCGM and translate table have beenloaded. A default FCB has been loaded matching the paperlength setting on the operator’s panel.

Solution: None required.

327 Index

Index

AABEND Codes, 2

Abnormal End Codes, 2

Attention Interrupt, 61

CCCWtrace, 15

Channel Command Word Trace, 15

CKDMAP, 19

Control Card Editor, 5

Count–Key–Data Map, 19

DDEFINE, 47

GGenerate Stand–Alone Programs, 53

GENSAPGM, 53

LLIBLOOK, 109

LIBMOUNT, 91

Library Look, 109

Library Mount Function, 91

Library Storage Module Exerciser, 63

LSMEXER, 63

MMPST Main Processing, 117

MPST Stand–alone Executive, 263

MPSTCCE messages, 5

MPSTCCW messages, 15

MPSTCKM messages, 19

MPSTCPY messages, 25

MPSTDEF messages, 47

MPSTGSA messages, 53

MPSTINT messages, 61

MPSTLEX messages, 63

MPSTLIB messages, 91

MPSTLOC messages, 109

MPSTMAIN, 117

328 MPST Messages and Codes Manual – Version 2.04

MPSTMAN messages, 117

MPSTRLB messages, 129

MPSTSAE, 263

MPSTTIP Messages, 151

MPSTTMC messages, 171

MPSTTRK messages, 157

MPSTTSC messages, 177

MPSTVSC messages, 201

MPSTVTM messages, 219

MPSTWRC messages, 223

MPSTWRD messages, 251

MSAE messages, 263

RRandom Locate Block, 129

Return Codes, 1

RLB, 129

SStand–alone Executive, 263

TTape Copy, 25

Tape Independent Protocol Set, 151

Tape Monitor and Control , 171

Tape Scan, 177

TAPESCAN, 177

Terminal Control Unit Verification, 219

TIPS, 151

TMC , 171

Track Dump, 157

TRKDUMP, 157

VVOLSCAN, 201

Volume Scan, 201

VTERM, 219

WWRCART, 223

WRDISK, 251

Write–Read Cartridge, 223

Write–Read Disk, 251

Reader’s Comment Form

Manual Name: MPST Messages & Codes Manual, Version 2.04 PN: 112151207

Please check or fill in the items: adding explanations/comments in the space provided.

Which of the following terms best describes your job?

� Field Engineer � Manager � Programmer � Systems Analyst

� Engineer � Mathematician � Sales Rep. � Systems Engineer

� Instructor � Operator � Student/Trainee � Other (explain below)

How did you use this publication?

� Introductory text � Reference Manual � Student/Trainee � Instructor text

� Other (explain)

Did you find the material easy to read and understand? � Yes � No (explain below)

Did you find the material organized for convenient use? � Yes � No (explain below)

Specific criticisms (explain below):

Clarifications on pages

Additions on pages

Deletions of pages

Errors on pages

Explanations and other comments:

Note: Staples can cause problems with automated mail sorting equipment. Please use pressure sensitive orother gummed tape to seal this form. If you would like a reply, please supply your name and address on thereverse side of this form.

Thank you for your cooperation. No postage stamp is necessary if mailed in the U.S.A.

FOLD HERE AND TAPE DO NOT STAPLE FOLD HERE AND TAPE

NO POSTAGENECESSARY

IF MAILEDIN THE

UNITED STATES

FIRST CLASS MAIL PERMIT NO. 2 LOUISVILLE, CO

BUSINESS REPLY MAIL

POSTAGE WILL BE PAID BY ADDRESSEE

MANAGER, WWCS STRATEGIC TOOLSSTORAGE TECHNOLOGY CORPORATION

ONE STORAGETEK DRIVELOUISVILLE CO 80027–9984

If you would like a reply, please print:

Your Name:

Company Name:

Street Address:

Department:

TO COMPLY WITH POSTAL REGULATIONS, FOLD EXACTLY ON DOTTED LINES AND TAPE (DO NOT STAPLE)

MS 4361

CU

T A

LON

G T

HIS

LIN

EC

UT

ALO

NG

TH

IS L

INE