multi parameter monitor with transmitter ds-7001 · 2014. 7. 23. · defibrillator protection...

2
Waveforms and measured values are shown on the color LCD Waveforms and measured values are shown on the color LCD Digital transmission of ECG 1ch, Respiration and SpO 2 DC operation with optional built-in battery Waveforms can be stored into an optional CF card for reviewing Compact and lightweight design for transport monitoring Multi Parameter Monitor with Transmitter Integrating Telemetry Transmitter into the compact monitor enables multi-parameter monitoring throughout the wireless network. Integrating Telemetry Transmitter into the compact monitor enables multi-parameter monitoring throughout the wireless network. DS - 7001 Feature Feature

Upload: others

Post on 05-Dec-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Multi Parameter Monitor with Transmitter DS-7001 · 2014. 7. 23. · Defibrillator protection Provided SpO2 Module Nellcor SpO2 technology Measuring method 2 Wavelength Pulsation

Waveforms and measured values are shown on the color LCDWaveforms and measured values are shown on the color LCDDigital transmission of ECG 1ch, Respiration and SpO2

DC operation with optional built-in batteryWaveforms can be stored into an optional CF card for reviewingCompact and lightweight design for transport monitoring

Multi Parameter Monitor with Transmitter

Integrating Telemetry Transmitter into the compact monitor enables multi-parameter monitoring throughout the wireless network.

Integrating Telemetry Transmitter into the compact monitor enables multi-parameter monitoring throughout the wireless network.

DS-7001

FeatureFeature

Page 2: Multi Parameter Monitor with Transmitter DS-7001 · 2014. 7. 23. · Defibrillator protection Provided SpO2 Module Nellcor SpO2 technology Measuring method 2 Wavelength Pulsation

DS-7001 Specifications

±

Parameters ECG, RESP, SpO2 and NIBPDisplay Size 3.5 inch TFT color LCD Waveform ECG, RESP, PULSE Measurement NIBP(SYS/DIA/MEAN), HR, RR, SpO2, PRAlarm Limits HR, RR, APNEA, NIBP, SpO2, PRECG Lead II Input impedance 5 M  or more Max. input range 5mV Pacemaker detection ProvidedRespiration� Measuring method Impedance Measuring electrodes RA & LFDefibrillator protection ProvidedSpO2 Module Nellcor SpO2 technology Measuring method 2 Wavelength Pulsation Measuring range 1 ~ 100 % Measuring accuracy  2% (70~100%)NIBP Measuring method Oscillometric Measuring range Adult: 10~280mmHg Child: 10~180mmHg Neonate: 10~120mmHgTelemetry Modulation mode Digital, Frequency shift keying Transmission frequency 400MHz band Transmitted Waveform ECG 1ch, SpO2, Resp Transmitted Value Measured Value, Alarm Flag Status FlagTrending up to 120 NIBP measurements with HR and SpO2

Recording Method CF recording or Telemetry remote recording CF recording Storage media:Compact Flash Card Parameter: 2 waveforms and measured values Length: 12 or 24 sec. File format: Bitmap file (Windows) Telemetry remote recording: Depends on the receiver setting

GeneralPower requirements 115~240V AC 10% 12V DC (optional battery)Power consumption 40VA maximumBattery operation Approx. 60min.Weight Approx. 3Kg (incl. Battery)Dimensions 110 (W) x 280 (H) x 200 (D) mm

Ω

Associated Equipment

Standard AccessoriesAC power cable: CS-18Operation Manual

Optional Accessories

ECGRelay cable: CI-161Patient cable: CM-61(Electrosurgical knife protection)

Relay cable: CI-164Patient cable: #3382.0654.11(IEC)

SpO2

Relay cable: DOC-10

Sensors:Nellcor Oxi-Max/Oxisensor III series

NIBPCuff: CUF-7101 Large size

CUF-7102A Standard

CUF-7103 Small size

CUF-7104 Child

CUF-7105 Infant

Air hose: OA-7109A 1.5m

OA-7109B 3.5m

Extension hose:OA-7110A 1.5m

OA-7110B 3.5m

OthersBattery (DC12V, Ni-MH): T10HR-AAC-4781Memory card: FCF-128 CF card

Mount kit: OA-445

LX-5120 TransmitterDual-lead ECG, RESP

LX-5230 TransmitterDual-lead ECG, RESP, SpO2

LW-5500NTelemetry Receiver

DS-46002/4-patient Telemetry Central Station

DS-570016-patient Central Station