multi parameter monitor with transmitter ds-7001 · 2014. 7. 23. · defibrillator protection...
TRANSCRIPT
Waveforms and measured values are shown on the color LCDWaveforms and measured values are shown on the color LCDDigital transmission of ECG 1ch, Respiration and SpO2
DC operation with optional built-in batteryWaveforms can be stored into an optional CF card for reviewingCompact and lightweight design for transport monitoring
Multi Parameter Monitor with Transmitter
Integrating Telemetry Transmitter into the compact monitor enables multi-parameter monitoring throughout the wireless network.
Integrating Telemetry Transmitter into the compact monitor enables multi-parameter monitoring throughout the wireless network.
DS-7001
FeatureFeature
DS-7001 Specifications
±
Parameters ECG, RESP, SpO2 and NIBPDisplay Size 3.5 inch TFT color LCD Waveform ECG, RESP, PULSE Measurement NIBP(SYS/DIA/MEAN), HR, RR, SpO2, PRAlarm Limits HR, RR, APNEA, NIBP, SpO2, PRECG Lead II Input impedance 5 M or more Max. input range 5mV Pacemaker detection ProvidedRespiration� Measuring method Impedance Measuring electrodes RA & LFDefibrillator protection ProvidedSpO2 Module Nellcor SpO2 technology Measuring method 2 Wavelength Pulsation Measuring range 1 ~ 100 % Measuring accuracy 2% (70~100%)NIBP Measuring method Oscillometric Measuring range Adult: 10~280mmHg Child: 10~180mmHg Neonate: 10~120mmHgTelemetry Modulation mode Digital, Frequency shift keying Transmission frequency 400MHz band Transmitted Waveform ECG 1ch, SpO2, Resp Transmitted Value Measured Value, Alarm Flag Status FlagTrending up to 120 NIBP measurements with HR and SpO2
Recording Method CF recording or Telemetry remote recording CF recording Storage media:Compact Flash Card Parameter: 2 waveforms and measured values Length: 12 or 24 sec. File format: Bitmap file (Windows) Telemetry remote recording: Depends on the receiver setting
GeneralPower requirements 115~240V AC 10% 12V DC (optional battery)Power consumption 40VA maximumBattery operation Approx. 60min.Weight Approx. 3Kg (incl. Battery)Dimensions 110 (W) x 280 (H) x 200 (D) mm
Ω
Associated Equipment
Standard AccessoriesAC power cable: CS-18Operation Manual
Optional Accessories
ECGRelay cable: CI-161Patient cable: CM-61(Electrosurgical knife protection)
Relay cable: CI-164Patient cable: #3382.0654.11(IEC)
SpO2
Relay cable: DOC-10
Sensors:Nellcor Oxi-Max/Oxisensor III series
NIBPCuff: CUF-7101 Large size
CUF-7102A Standard
CUF-7103 Small size
CUF-7104 Child
CUF-7105 Infant
Air hose: OA-7109A 1.5m
OA-7109B 3.5m
Extension hose:OA-7110A 1.5m
OA-7110B 3.5m
OthersBattery (DC12V, Ni-MH): T10HR-AAC-4781Memory card: FCF-128 CF card
Mount kit: OA-445
LX-5120 TransmitterDual-lead ECG, RESP
LX-5230 TransmitterDual-lead ECG, RESP, SpO2
LW-5500NTelemetry Receiver
DS-46002/4-patient Telemetry Central Station
DS-570016-patient Central Station