mtlbe report. pueblo jad

Upload: john-alfrey-dondiego-pueblo

Post on 05-Apr-2018

224 views

Category:

Documents


0 download

TRANSCRIPT

  • 7/31/2019 MTLBE Report. Pueblo JAD

    1/49

    REPORTERS:Artuz, Jonesa Jay

    Pueblo, John Alfrey D.Sael, Chellamae A.Saleh, Shahina S.

    Quijano, Quinee T.

  • 7/31/2019 MTLBE Report. Pueblo JAD

    2/49

    BEFORE AFTER

  • 7/31/2019 MTLBE Report. Pueblo JAD

    3/49

    ObjectiveIntroduction

    ContentsRequirements for the accredition of water analysislaboratoriesMinimum equipments for each service.Minimun required refference for laboratory.SynthesisEvaluation

  • 7/31/2019 MTLBE Report. Pueblo JAD

    4/49

    After completion of this lesson our classmateswill be able to:

    explain the importance of water testinglaboratories.identify the standard laboratory proceduresin the examination of drinking water.enumerate the requirements foraccreditation of water analysis laboratories.

  • 7/31/2019 MTLBE Report. Pueblo JAD

    5/49

    -PD 866 (Code of sanitation of Philippines)

    -Examination of drinking water ---Department of Health.

  • 7/31/2019 MTLBE Report. Pueblo JAD

    6/49

    January 1968 (Ministry of HumanSettlements and Ecology)

    -published a three- volume PhilippineStandards Methods for Air and WaterAnalysis September 1978 (Ministry of Health)-issued a revised National Standards forDrinking Water

  • 7/31/2019 MTLBE Report. Pueblo JAD

    7/49

    -assurance that accepted procedures

    available for determination of STANDARD

    -adherence to the procedures allowscomparability of results of analysis within asingle laboratory and between laboratories.

  • 7/31/2019 MTLBE Report. Pueblo JAD

    8/49

    Water analysis laboratories maybeaccredited for separate services like:

    BacteriologicalChemicalRadiologicalBiological

  • 7/31/2019 MTLBE Report. Pueblo JAD

    9/49

    Name, citizenship and domicile of the head of the laboratoryMunicipality and where it is establishedName of establishmentName, citizenship and domicile of ownerScope and nature of work, specifying procedures

    Statement that applicant has complied with allbusiness requirements

    Tax clearance for proceeding year

  • 7/31/2019 MTLBE Report. Pueblo JAD

    10/49

    sanitary engineer .In areas where there may not be a licensed

    sanitary engineer,licensed chemistmedical technologist

    pharmacist

  • 7/31/2019 MTLBE Report. Pueblo JAD

    11/49

    headmanageor supervise up to 3 waterlaboratories

  • 7/31/2019 MTLBE Report. Pueblo JAD

    12/49

    technical aspect:physical bacteriological,

    chemical,biological and radiological examinations of water ,

    should be a registered: pharmacist,medical technologist,or chemist.

  • 7/31/2019 MTLBE Report. Pueblo JAD

    13/49

    must have been trained and musthave at least 1 year experience.

    may supervise not more than two

    skilled workers .

  • 7/31/2019 MTLBE Report. Pueblo JAD

    14/49

    Laboratory support personnelsuch as;laboratory aides - are needed to clean glassware's, assist in thepreparation of media.

    Each service must therefore be operated by at least oneregistered professional, one laboratory aide .

    Bacteriological service-----handle at most 30 samples/day

    Chemical service -----5 samples for routine chemistry .

  • 7/31/2019 MTLBE Report. Pueblo JAD

    15/49

    Work rooms must be:house in a permanent buildingWell-ventilated

    correlate with the volume and type of workA bench height of 90 cm providesconvenience for workers

    adequate running water.Adequate physical provisions for the safetyof the laboratory personnel must beprovided.

  • 7/31/2019 MTLBE Report. Pueblo JAD

    16/49

  • 7/31/2019 MTLBE Report. Pueblo JAD

    17/49

    Quality -to meet the levels of sensitivity,reliability and should only need

    minimum service repair.Increased workloadEfficiency and effectively.Highest grade of quality media andreagent are to be used

  • 7/31/2019 MTLBE Report. Pueblo JAD

    18/49

    A. bacteriological Analysis Service

    B. biological Analysis Service

    C. Physical and Chemical Analysis Services

    D. Radiologic Analysis Service

  • 7/31/2019 MTLBE Report. Pueblo JAD

    19/49

  • 7/31/2019 MTLBE Report. Pueblo JAD

    20/49

    Multiple-tube fermentation technique

  • 7/31/2019 MTLBE Report. Pueblo JAD

    21/49

    IMVIC test Standard plate count

  • 7/31/2019 MTLBE Report. Pueblo JAD

    22/49

    Fecal coliform test Optional-test for fecal streptococcal group

  • 7/31/2019 MTLBE Report. Pueblo JAD

    23/49

  • 7/31/2019 MTLBE Report. Pueblo JAD

    24/49

  • 7/31/2019 MTLBE Report. Pueblo JAD

    25/49

  • 7/31/2019 MTLBE Report. Pueblo JAD

    26/49

  • 7/31/2019 MTLBE Report. Pueblo JAD

    27/49

    ColorOdorPh valueSpecific conductanceTasteTemperatureTurbidityTotal solidsHardness

    AcidityAlkalinityAluminumArsenicBariumCadmiumCalcium free CO2ChlorideChlorine (residual)

    TEST FOR

  • 7/31/2019 MTLBE Report. Pueblo JAD

    28/49

    Chromium(hezavalent)CopperCyanideFluorideIronLeadMagnesiumManganeseMercury

    Nitrogen, ammoniaNitrogen nitrateOil and greaseTotal organic carbonOxygen, dissolvedOxygen, demand,biochem.PesticidesPhenolsPhospahate

  • 7/31/2019 MTLBE Report. Pueblo JAD

    29/49

    PotassiumResidueSeleniumSilica, dissolvedSilver

    SodiumSulfateSulfideSulfiteSurfactantzinc

  • 7/31/2019 MTLBE Report. Pueblo JAD

    30/49

  • 7/31/2019 MTLBE Report. Pueblo JAD

    31/49

  • 7/31/2019 MTLBE Report. Pueblo JAD

    32/49

    Total radioactive strontium in H2O

    Strontium --- 90 in H2OTotal Radium (Precipitation Technique)Radium ---- 266 by Radon (Soluble, suspendedand Total)

  • 7/31/2019 MTLBE Report. Pueblo JAD

    33/49

  • 7/31/2019 MTLBE Report. Pueblo JAD

    34/49

    IncubatorWaterbath, 37C45C 0.5(Escherichia coli test is to be performed)

    AutoclavepH meterAnalytical balanceColony counter

    MicroscopeHot plate/stoveBunsen burnerRefrigerator

  • 7/31/2019 MTLBE Report. Pueblo JAD

    35/49

    Incubator

    Waterbath

  • 7/31/2019 MTLBE Report. Pueblo JAD

    36/49

    Autoclave

    pH meter

  • 7/31/2019 MTLBE Report. Pueblo JAD

    37/49

    Analytical balance

    Hot plate/stove

  • 7/31/2019 MTLBE Report. Pueblo JAD

    38/49

  • 7/31/2019 MTLBE Report. Pueblo JAD

    39/49

    Bunsen burner

    Refrigerator

  • 7/31/2019 MTLBE Report. Pueblo JAD

    40/49

    pH meterOven sterilizingCandle turbidimeter

    Pipette washerSpectrophotometer, spectronic 20, or AAMagnetic stirrerWaterbathRefrigeratorGas chromatographerVacuum filter

  • 7/31/2019 MTLBE Report. Pueblo JAD

    41/49

    Oven sterilizing

    Candle turbidimeter

  • 7/31/2019 MTLBE Report. Pueblo JAD

    42/49

    Pipette washer

    Spectrophotometer

    Magnetic stirrer

  • 7/31/2019 MTLBE Report. Pueblo JAD

    43/49

    Gas chromatographer Vacuum filter

  • 7/31/2019 MTLBE Report. Pueblo JAD

    44/49

    1. Water sampler, any of the following:a. Van dornb. Kemmerrerc. Wansend. Buttnere. Improvised Neyer or LLDAs Modifier

    Sampler2. Water pump with graduated intake3. Bottom drodge4. Inverted microscope5. Compound microscope

  • 7/31/2019 MTLBE Report. Pueblo JAD

    45/49

    Bottom dredge

    Inverted microscope

  • 7/31/2019 MTLBE Report. Pueblo JAD

    46/49

  • 7/31/2019 MTLBE Report. Pueblo JAD

    47/49

    a. Philippine Standard Methods for Air andWater Analysis, vol.1 and vol.2, HumanSettlements Commission, January 1978Standard Methods for the Examination of Water and Wastewater: APHA, AWWA,WFCF, 14th edition.

    National Standards for Drinking Water,Bureau of Research and Laboratories,Ministry of Health, 1978.

  • 7/31/2019 MTLBE Report. Pueblo JAD

    48/49

  • 7/31/2019 MTLBE Report. Pueblo JAD

    49/49

    In every glass of water we drink, some of the water has already passed through fishes, trees, bacteria,

    worms in the soil, and many other organisms,including people...Living systems cleanse water and

    make it fit, among other things, for humanconsumption.

    ELLIOT A. NORSE