INSTALLATION INSTRUCTIONS Instrucciones de instalación Installationsanleitung Instruções de Instalação Istruzioni di installazione Installatie-instructies Instructions d´installation FUSION PORTRAIT MEDIUM TILT MOUNT Spanish Product Description German Product Description Portuguese Product Description Italian Product Description Dutch Product Description French Product Description MTAPU

Upload: others

Post on 26-Feb-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: MTAPU INSTALLATION INSTRUCTIONSThe MTAP has been designed to be mounted directly onto either a 16 inch on center wood stud wall or concrete wall. The MTAP has brackets which allow

I N S T A L L A T I O N I N S T R U C T I O N S

Instrucciones de instalaciónInstallationsanleitungInstruções de Instalação

Istruzioni di installazioneInstallatie-instructiesInstructions d´installation

FUSION PORTRAIT MEDIUM TILT MOUNTSpanish Product DescriptionGerman Product Description

Portuguese Product Description Italian Product DescriptionDutch Product Description

French Product Description

MTAPU

Page 2: MTAPU INSTALLATION INSTRUCTIONSThe MTAP has been designed to be mounted directly onto either a 16 inch on center wood stud wall or concrete wall. The MTAP has brackets which allow

MTAPU Installation Instructions

2

DISCLAIMERMilestone AV Technologies, and its affiliated corporations andsubsidiaries (collectively "Milestone"), intend to make thismanual accurate and complete. However, Milestone makes noclaim that the information contained herein covers all details,conditions or variations, nor does it provide for every possiblecontingency in connection with the installation or use of thisproduct. The information contained in this document is subjectto change without notice or obligation of any kind. Milestonemakes no representation of warranty, expressed or implied,regarding the information contained herein. Milestone assumesno responsibility for accuracy, completeness or sufficiency ofthe information contained in this document.

Chief® is a registered trademark of Milestone AV Technologies.All rights reserved.

IMPORTANT WARNINGS ANDCAUTIONS!

WARNING: A WARNING alerts you to the possibility ofserious injury or death if you do not follow the instructions.

CAUTION: A CAUTION alerts you to the possibility ofdamage or destruction of equipment if you do not follow thecorresponding instructions.

WARNING: Failure to read, thoroughly understand, andfollow all instructions can result in serious personal injury,damage to equipment, or voiding of factory warranty! It is theinstaller’s responsibility to make sure all components areproperly assembled and installed using the instructionsprovided.

WARNING: Failure to provide adequate structural strengthfor this component can result in serious personal injury ordamage to equipment! It is the installer’s responsibility tomake sure the structure to which this component is attachedcan support five times the combined weight of all equipment.Reinforce the structure as required before installing thecomponent. The wall to which the mount is being attachedmay have a maximum drywall thickness of 5/8" (1.6cm).

WARNING: Exceeding the weight capacity can result inserious personal injury or damage to equipment! It is theinstaller’s responsibility to make sure the combined weight ofall components located between the MTAPU up to (andincluding) the display does not exceed 125 lbs (56.7 kg).

DIMENSIONS

18.75 476.2

12.00 304.8

1.50 38.1

.34 8.6

1.25 31.8

11.00 279.4

9.58 243.4

.81 20.6

11.00 279.4

16.00 406.4

1.37 34.9 .75 19.1

6.00 152.4

1255.41 137.55.91 1506.40 162.56.89 1757.38 187.57.87 2008.37 212.58.86 2259.35 237.59.84 25010.33 262.510.83 27511.32 287.511.81 300

1.97

NOTES:MINIMUM HORIZONTAL MOUNTING PATTERN 3.937"[100mm].1.MAXIMUM HORIZONTAL MOUNTING PATTERN, WITHOUT SWITCHING KNOB, 15.75"[400mm].2.MAX HORIZONTAL MOUNTING PATTERN, WITH SWITCHING KNOB, 18.10"[460mm].3.FOR RECESSED APPLICATIONS, MINIMUM VERTICAL LIFT FOR HOOK ENGAGEMENT IS .58"[14.7mm].4.OVERALL MOUNT DEPTH AT 0° OF TILT IS 2.40"[61mm].

MEASUREMENTS IN: [MILLIMETERS] INCHES

Page 3: MTAPU INSTALLATION INSTRUCTIONSThe MTAP has been designed to be mounted directly onto either a 16 inch on center wood stud wall or concrete wall. The MTAP has brackets which allow

Installation Instructions MTAPU

3

LEGEND

TOOLS REQUIRED FOR INSTALLATION

Tighten Fastener

Apretar elemento de fijación

Befestigungsteil festziehen

Apertar fixador

Serrare il fissaggio

Bevestiging vastdraaien

Serrez les fixations

Loosen Fastener

Aflojar elemento de fijación

Befestigungsteil lösen

Desapertar fixador

Allentare il fissaggio

Bevestiging losdraaien

Desserrez les fixations

Hex-Head Wrench

Llave de cabeza hexagonal

Sechskantschlüssel

Chave de cabeça sextavada

Chiave esagonale

Zeskantsleutel

Clé à tête hexagonale

Pencil Mark

Marcar con lápiz

Stiftmarkierung

Marcar com lápis

Segno a matita

Potloodmerkteken

Marquage au crayon

Drill Hole

Perforar

Bohrloch

Fazer furo

Praticare un foro

Gat boren

Percez un trou

By Hand

A mano

Von Hand

Com a mão

A mano

Met de hand

À la main

#27/32" (5.5mm) Wood Stud 5/16" (7.9mm) Concrete

Page 4: MTAPU INSTALLATION INSTRUCTIONSThe MTAP has been designed to be mounted directly onto either a 16 inch on center wood stud wall or concrete wall. The MTAP has brackets which allow

MTAPU Installation Instructions

4

PARTS

INSTALLATIONThe MTAP has been designed to be mounted directly ontoeither a 16 inch on center wood stud wall or concrete wall. TheMTAP has brackets which allow the TV to be tilted.

Locate Mounting Site

WARNING: IMPROPER INSTALLATION CAN LEAD TOMOUNT FALLING CAUSING SEVERE PERSONAL INJURYOR DAMAGE TO EQUIPMENT! It is the installersresponsibility to make certain the structure to which themount is being attached is capable of supporting five timesthe weight of the MTAP not to exceed 125 lbs (56.7 kg).

NOTE: Proceed to either the Installing to a Wood Stud Wallsection or the Installing to a Concrete Wall section.

Installing to a Wood Stud Wall

1. Determine the center of the TV screen, and where it shouldbe located on the wall.

2. Locate the closest stud to the left and right of the selectedlocation.

NOTE: If the screen area lies over a stud, use that stud and thestud to either the left or right of it.

3. Line up the notches on mount with center of screen markingto determine vertical center. (See Figure 1)

4. Measure up 6" from the center point to mark location of theupper mounting slots.

CustomMTAPXXXHardware

[Included only withMTAPXXX Models]

F3 (6)

F5 (6)

A (1)

B (1)

F1 (8)M4x16mm

F2 (6)M4x20mm M4x25mm

F4 (6)M5x16mm M5x20mm

F6 (6)M5x25mm

F7 (6)M6x16mm

F8 (6)M6x25mm

F15 (1) M5

F9 (6) M8x20mm

F10 (6) M8x30mm

F11 (4) M8x50mm

F13 (8).750x.323x.250

F14 (8).750x.344x.500

F12 (8)

D1 (4) 5/16"

D3 (4) 5/16"

D2 (4)5/16" x 2-1/2"

F (1)

E (1)

E1 (8) 5/16"

E2 (8)5/16" x 1/2"

E3 (1) 3/16"

[Wall Mount]

[Right Upright]

C (1)[Left Upright]

[UniversalWasher]

D (1)

Page 5: MTAPU INSTALLATION INSTRUCTIONSThe MTAP has been designed to be mounted directly onto either a 16 inch on center wood stud wall or concrete wall. The MTAP has brackets which allow

Installation Instructions MTAPU

5

Figure 1

5. Using a level, mark the wall on each stud to attach themount through the upper mounting slots. (See Figure 2)

Figure 2

WARNING: ELECTRICAL SHOCK HAZARD! CUTTINGOR DRILLING INTO ELECTRICAL CORDS OR CABLESCAN CAUSE DEATH OR SERIOUS PERSONAL INJURY!ALWAYS make certain area behind mounting surface is freeof electrical wires and cables before drilling or installingfasteners.

WARNING: EXPLOSION AND FIRE HAZARD! CUTTINGOR DRILLING INTO GAS PLUMBING CAN CAUSE DEATHOR SERIOUS PERSONAL INJURY! ALWAYS make certainarea behind mounting surface is free of gas, water, waste, orany other plumbing before cutting, drilling, or installingfasteners.

Figure 3

6. Drill one 7/32" pilot hole in each stud.

7. Use two 5/16 x 2-1/2" lag bolts (D2) and two 5/16" flatwashers (D3) to attach top of mount to wall. (See Figure 3)

8. Mark the attachment points for the lower mounting slots,making sure the attachment points are located on the studs.(See Figure 3)

9. Drill 7/32" pilot holes at markings for lower mounting holes.(See Figure 3)

10. Use two 5/16 x 2-1/2" lag bolts (D2) and two 5/16" flatwashers (D3) to attach the mount to the wall through thelower mounting holes. (See Figure 3)

11. Slide rails to approximate center of screen location.

Installing to a Concrete Wall

1. Determine the center of the TV screen, and where it shouldbe located on the wall.

2. Line up the notches on mount with center of screen markingto determine vertical center. (See Figure 1)

3. Measure up 6" from the center point to mark location of theupper mounting slots. (See Figure 1)

4. Using a level, mark the wall through both upper mountingslots. (See Figure 4)

WARNING: ELECTRICAL SHOCK HAZARD! CUTTINGOR DRILLING INTO ELECTRICAL CORDS OR CABLESCAN CAUSE DEATH OR SERIOUS PERSONAL INJURY!ALWAYS make certain area behind mounting surface is freeof electrical wires and cables before drilling or installingfasteners.

WARNING: EXPLOSION AND FIRE HAZARD! CUTTINGOR DRILLING INTO GAS PLUMBING CAN CAUSE DEATHOR SERIOUS PERSONAL INJURY! ALWAYS make certainarea behind mounting surface is free of gas, water, waste, orany other plumbing before cutting, drilling, or installingfasteners.

Center of screen

6"

Vertical centerof mount

5 x 2

(D3) x 4

710 (D2) x 4

6 x 4

8

9

Page 6: MTAPU INSTALLATION INSTRUCTIONSThe MTAP has been designed to be mounted directly onto either a 16 inch on center wood stud wall or concrete wall. The MTAP has brackets which allow

MTAPU Installation Instructions

6

Figure 4

5. Drill one 5/16" pilot hole at each marking.

6. Install an anchor (D1) into each pilot hole using a hammer.

7. Use two 5/16 x 2-1/2" lag bolts (D2) and two 5/16" flatwashers (D3) to attach top of mount to anchors in wall.

8. Mark the attachment points for the lower mounting slots.(See Figure 4)

9. Drill one pilot hole at each marking for lower mountingholes. (See Figure 4)

10. Install an anchor (D1) into each pilot hole using a hammer.

11. Use two 5/16 x 2-1/2" lag bolts (D2) and two 5/16" flatwashers (D3) to attach the mount to the wall through thelower mounting holes. (See Figure 4)

12. Slide rails to approximate center of screen location.

Attaching Upright Brackets to Display

1. Vertically align the center of the uprights (B and C) withcenter of screen. (See Figure 5)

NOTE: The diamond-shape opening in the uprights (B and C)corresponds to the vertical center of the upright.

WARNING: IMPROPER INSTALLATION CAN LEAD TODISPLAY FALLING CAUSING SERIOUS PERSONALINJURY OR DAMAGE TO EQUIPMENT! Using screws ofimproper size may damage your display. Properly sizedscrews will easily and completely thread into displaymounting holes. If spacers are required, be sure to use longerscrews of the same diameter.

2. Select correct screws, spacers (if necessary) and washersfrom the hardware bag (F) and attach brackets to back ofdisplay. (See Figure 5)

Figure 5

Switching Upright Brackets (Optional)

If an installation situation makes adjusting the location ofupright brackets necessary, there are several options.

1. The wall bracket may be adjusted side to side at the pointsof attachment. (See Figure 6)

2. The location of the left and right upright brackets may beswitched, with the knobs on the MTAP upright bracketsfacing the inside of the mount. (See Figure 6)

7 11

(D2) x 4 (D3) x 4

8

56

4

9x4(D1) x 410

2

Center of Upright

(C)

(B)

(F13 or F14)

(F1 - F11) x 4

(F12) x 4

Page 7: MTAPU INSTALLATION INSTRUCTIONSThe MTAP has been designed to be mounted directly onto either a 16 inch on center wood stud wall or concrete wall. The MTAP has brackets which allow

Installation Instructions MTAPU

7

Figure 6

3. If necessary, the tilt upright bracket knobs may be switchedto allow the brackets to be reversed. (See Figure 7)

a. Remove display from mount.b. Remove brackets from display.c. Hold the right upright bracket horizontally, tightly gripping

it so that spacers do not move.d. Remove the knob, washer and screw.e. Replace the knob, washer and screw in the opposite

order, with the knob on the inside of the bracket.f. Switch the right upright bracket to the left side of the wall

mount.g. Repeat Steps 3c through 3f with the left upright bracket.

Figure 7

Attaching Display to Wall Mount

1. Push upright brackets tabs all the way down so that thelower mounting slot is blocked. (See Figure 8)

2. Hang the top hook of upright brackets onto the top bar of themount. The bottom of the display will be away from the wall.

3. Route cables between wall and bars.

CAUTION: PINCH POINTS! Keep fingers, hands andcables out of pinch point areas.

1

2

Knobs

3d

3e

Knobs to outside of brackets

Page 8: MTAPU INSTALLATION INSTRUCTIONSThe MTAP has been designed to be mounted directly onto either a 16 inch on center wood stud wall or concrete wall. The MTAP has brackets which allow

MTAPU Installation Instructions

8

Figure 8

4. Move screen towards the wall by pulling display bottomaway from wall and pushing the upright brackets tabs upone notch to the detent which you will be able to feel(approximately half way up). (See Figure 8)

5. Push bottom of display toward the wall bracket so that lowerlatch on upright brackets surrounds lower bar of wall mount.

6. Raise upright brackets tabs all the way to secure thebrackets onto the wall mount. (See Figure 8)

Locking Mount (Optional)

Add padlock (not included) to interface bracket tab to lock theMTAP mount. (See Figure 9)

Figure 9

41 6

Latchopen

Latchclosed

Upright bracket tabMounting Slot Blocked

Add padlock (Optional)

Page 9: MTAPU INSTALLATION INSTRUCTIONSThe MTAP has been designed to be mounted directly onto either a 16 inch on center wood stud wall or concrete wall. The MTAP has brackets which allow

Installation Instructions MTAPU

9

Page 10: MTAPU INSTALLATION INSTRUCTIONSThe MTAP has been designed to be mounted directly onto either a 16 inch on center wood stud wall or concrete wall. The MTAP has brackets which allow

MTAPU Installation Instructions

10

Page 11: MTAPU INSTALLATION INSTRUCTIONSThe MTAP has been designed to be mounted directly onto either a 16 inch on center wood stud wall or concrete wall. The MTAP has brackets which allow

Installation Instructions MTAPU

11

Page 12: MTAPU INSTALLATION INSTRUCTIONSThe MTAP has been designed to be mounted directly onto either a 16 inch on center wood stud wall or concrete wall. The MTAP has brackets which allow

MTAPU Installation Instructions

USA/International A 8401 Eagle Creek Parkway, Savage, MN 55378P 800.582.6480 / 952.894.6280F 877.894.6918 / 952.894.6918

Europe A Fellenoord 130 5611 ZB EINDHOVEN, The NetherlandsP +31 (0)40 2668620F +31 (0)40 2668615

Asia Pacific A Room 24F, Block D, Lily YinDu International BuildingLuoGang, BuJi Town, Shenzhen, CHINA.

P +86-755-8996 9226F +86-755-8996 9217

Chief Manufacturing, a products divisionof Milestone AV Technologies

8800-002030 Rev012011 Milestone AV Technologies, a

Duchossois Group Companywww.chiefmfg.com01/11