mt plus multi-turn electric actuator manual · meter waterhead. for a deeper immersion, the three...
TRANSCRIPT
Indice de protection
IP68 Enclosure protection
25Nm
Facteur de marche
50% Duty cycle
Anticondesation intégrée
Anticondesation Heater
Positionnement
POSI Positioning
BLUETOOTH®
®�
5 250
Actionneur électrique Electric actuator
Elektrische Stellantrieb Actuador eléctrico
MT�
ENCOMBREMENTS
19
Safety instructions .......................................................................... 20
Actuator description ........................................................................ 21
Dimensions ..................................................................................................... 22
Valve connection ................................................................................. 23
Position indicator ............................................................................... 24
Electric wiring .......................................................................................... 25 Recommendations ..................................................................................................................... 25
Multipin connector ...................................................................................................................... 26
Electronic boards .............................................................................. 27
Operating modes ................................................................................. 28 Wired mode (permanent and pulse signal .................................................................................. 29
Positioning mode ........................................................................................................................ 30
Bluetooth® mode (local control and weekly programming) ......................................................... 32
Technical specifications ........................................................ 33
Codification .................................................................................................. 34
Français ......................................................................... 3
English ........................................................................ 19
Deutsch ................................................................. 35
Español ...................................................................... 51
45
678
9
11
1817161413
12
910
20
DESCRIPTION These electric actuators have been designed to perform the control of a linear valve or a reductor. Please consult us for any different application. We cannot be held responsible if the mentioned actuators are used for any other purpose.
TRANSPORT AND STORAGE The forwarding agents being held as responsible for damages and delays of the delivered goods, the consignees are obliged to express if applicable their reserves, prior to accept the goods. The goods delivered directly ex works are sub-ject to the same conditions. The transport to the place of destination is carried out by using rigid packing material. The products must be stored in clean, dry, and ventilated places, preferably on appropriate palettes or shelves. Actuators should not be stored upside down.
MAINTENANCE Maintenance is ensured by our factory. If the supplied product does not work, please check the wiring according to the electric diagram as well as the power supply of the electric actuator in question. For any question, please contact our after-sales service. To clean the outside of the actuator, use a lint and soapy water. DO NOT USE ANY CLEANING PRODUCT WITH SOL-VENT OR ALCOHOL.
WARRANTY 100% of the actuators are fully tested and pre-set in our factory. These products have a 3-year warranty from the delivery date or 3 times what the EN 15714-2 standard imposes (therefore 3 x 10 000 open-close operations of 25 turns) against all types of manufacturing and material faults (operating time and model class according to standard IEC34).
RETURN OF GOODS When the actuator receives his actuator, he must check its conformity according to its definition. The acceptance of the goods by the purchaser disclaims the supplier of all responsibility if the purchaser discovers any non-conformity after the date of acceptance. In such case, the repair cost will be borne by the purchaser who will also exclusively bear all financial consequences of any resulting damages. Returned goods will only be accepted if our prior agreement has been given to this procedure : the goods must be sent free of all cost and being shipped solely and in their original packing. The returned goods will be credited to the purchaser with a reduction of 40% on the unit’s price charged in accordance with the original invoice of the returned goods.
SAFETY INSTRUCTIONS (To be read prior to the installation of the product) The electric power supply must be switched-off before any intervention on the electric actuator (i.e. prior demounting its cover or manipulating the manual override knob). Any intervention must only be carried out by a qualified electrician or persons instructed in accordance with the regulations of electric engineering, safety, and all other applicable directives. Strictly observe the wiring and operation instructions as described in the manual: otherwise, the proper working of the actuator can not be guaranteed anymore. Verify that the indications given on the identification label of the actuator fully correspond to the characteristics of the electric supply. Any other use than that described by the manufacturer jeopardizes the protection provided by this apparatus.
MOUNTING INSTRUCTIONS (To be read prior to the installation of the product) Do not mount the actuator less than 30 cm from an electromagnetic disturbance source. Do not position the equipment so that it is difficult to operate the disconnecting device. Respect all safety rules during fitting, dismantling and porting of this apparatus.
4
21
ACTUATOR DESCRIPTION
8
1 Aluminium cover + transparent porthole
2 Position indicator
3 Detection switches • Motor + feedback
4 Control and power supply electronic board
5 Housing
6 Valve stem bore + capsule
7 Multipin connector
8 Manual override
9 Drive bush for threaded valve Stem A form (option)
10 Output for keyed bore Ø20 max. (B3)
11 Drive bush for keyed bore Ø42 max. (B1) (option)
12 Brushless motor
9 10 11 12
7 6 5 4 3 2 1
5
22 6
23
VALVE CONNECTION
C FORM
A FORM B1 FORM
B3 FORM
Form Description Form Description
A Drive bush for threaded valve stem (Ø25mm max.) Connection with four M10 threaded holes (depth 20mm) or four M8 threaded holes (depth 15mm)
B1
Drive bush for large keyed bore (Ø42mm & height 48mm max.) Connection with four M10 threaded holes (depth 20mm) or four M8 threaded holes (depth 15mm)
B3 Small keyed bore (Ø20mm max.). Connection with four (0° or 45°for F10) M10 threaded holes (depth 20mm) or four M8 threaded holes (depth 15mm)
C Shaft with tenons (Ø43mm). Connection with four (0° or 45° for F10) M10 threaded holes (depth 20mm) or four M8 threaded holes (depth 15mm)
7
24
The indicator consist of two adjustable transparent discs. The lower disc indicates the closed
position and the upper disc indicates the open position.
Opening
Closing
Indicator adjustment Operate the actuator into closed position and rotate the lower disc until the mark and the connecting flange are in the opposite direction.
Operate the actuator into open position and rotate the upper disc until the mark and the connecting flange are in the opposite direction.
8
25
ELECTRIC WIRING Recommendations
As stipulated in the applicable regulation, the connection to earth contact is compul-
sory for devices with working voltages exceeding 42 V.
The actuator is being always under power, it must be connected to a disconnection
system (switch, circuit breaker) to ensure the actuator’s power cut. The latter must
be closed to the actuator, easy to reach and marked as being the disconnecting
device for the equipment.
The temperature of the terminal can reach 90°C.
In case of long cables, please note the induction current shall not exceed 1mA.
To optimize the installation security, please connect the failure feedback signal.
The actuator can tolerate temporary overvoltage of the electrical grid up to ± 10 %
of its nominal system operating voltage.
It is necessary to connect all actuators to an electrical cabinet. The power supply
cables must have the RATED diameter for the maximum current supported by the
actuator and comply with IEC 60227 or IEC 60245 standards.
Our cable glands are designed for cables with a diameter between 7mm and
12mm. The white caps delivered with the actuator ensure a maximum tightness of 1
meter waterhead. For a deeper immersion, the three cable glands must be wired. A
cable gland is tight when it has been tighten by one turn ahead of contact between
rubber seal and nut.
The auxiliary limit switches must be connected with rigid wires. If the applied voltage
is higher than 42V, the user must foresee a fuse in the power supply line.
The feedback switches must be powered with the same voltage. The reinforced in-
sulation of the motor control allows voltages up to 250V AC/DC.
9
26
4 x CHC M6x30 inox A2 screws
Connector cover
3 x ISO M20 x 1,5 cable glands
Male connector
4 x M3x10 screws
Seal
To wire the actuator, unscrew the 4 CHC M6x30 screws, and the 4 M3x10 screws. The wiring can be realized without tool, just raising the strips in front of each pin. For the reassembly, make sure that the seal is correctly positionned in its groove to ensure tightness.
10
27
ELECTRONIC BOARDS
POWER 100V to 240V AC 50/60Hz and 100V to 300V DC
24V to 48V AC 50/60Hz and 24V to 72V DC
TP/PE
6
5
4 3
2 1
1 Power supply terminal 4 Feedback signal (positioning mode)
2 Failure report (24V 3A max.) 5 Learning mode panel (positioning mode)
3 Setpoint signal (positioning mode) 6 Functioning mode selection panel
FUSES SNBA050000 : 3 x T 5A, 250V Littlefuse SNBA051000 : 3 x 20A, 72V DC Shurter
TP/PE Protection earth
11
28
Op
era
ting
mo
des
Mode selection
Selection confirmation
Local control (Bluetooth®)
Weekly scheduler (Bluetooth®)
Wired (permanent & pulse signal)
Positioning (learning mode)
Positioning
Keyboard local control (available soon)
Functioning mode selection The « Next Mode » button scrolls the functionning modes in the following order:
Bluetooth® (local control) �
Bluetooth® (schedule) �
Wire control �
Learning mode (positioning) �
positioning
When the mode is selected, press « OK Mode » to confirm.
Description Wireless local control (Bluetooth®) : allows the use of the actuator from 20m maximum (in open field). This mode requires a smartphone or a tablet with the AXMART® software.
Weekly scheduler (Bluetooth®) : thanks to AXMART®, you can assign up to 20 repeatable tasks to each actuator. This mode requires a smartphone or a tablet with the AXMART® software.
Wire control: electric control - permanent (on-off or 3-modulating point) or pulse.
Positioning (learning mode) : this mode is needed for storing limit positions of the actuator.
Positioning : allows the control of the actuator with a 0-10V or 4-20mA setpoint signal.
12
29
OPERATING MODE Wired
Permanent wiring 3-modulating points
Permanent wiring ON/OFF
Wiring - MT models with pulse control
At least
500ms Between two impulssions
1 2 3
13 14 15 16 17 18
TP
PE
Open Close
Neutral Phase AC 50/60Hz
- + DC
1 2 3
13 14 15 16 17 18
TP
PE
Neutral Phase AC 50/60Hz
- + DC
Open
Neutral Phase AC 50/60Hz
- + DC
13 14 15 16 17 18
TP
PE
1 2 3 4
13
30
+ + - -
Setpoint signal
Feedback signal
4-20
mA
0-10
V
Learning mode - open position
Learning mode - storage
Learning mode - closed position
Led de validation (pos. 2) Validation led (pos.1)
Learning mode Put the power on
With the « Next Mode » and « Ok Mode » buttons, select the learning mode (the APPR led is on)
Press « APPR Close » button to drive the valve up to its closed position and keep both « APPR Close » and « APPR Mem » buttons pressed during 2 seconds.
The APPR1 led blinks and lights up. The closed position is correctly recorded
Press « APPR Open » button to drive the valve up to its open position and keep both « APPR Open » and « APPR Mem » buttons pressed during 2 seconds.
The APPR2 led blinks and lights up. The open position is correctly recorded Both open and closed positions are recorded. Select positioning (POSI) mode and press « OK Mode » to confirm.
Setpoint signal
Feedback According to its position, the actuator will provide a proportional voltage signal (0-10V) or a current signal (4-20mA). It’s possible to modify the feedback signal using the AXMART® software, but it requires changing the wiring.
14
31
OPERATING MODES Positioning
TP PE
13 14 15 16 17 18
1 2
Neutral Phase AC 50/60Hz
- + DC
Setpoint signal -
Setpoint signal +
feedback + (
feedback + (
feedback -
9 10 11
24
12
The 0-10V and 4-20mA feedback signals are not available at the same time.
15
32
Wireless local control AXMART® software allows the actuator control with maximum range of 20m (in open field).
Weekly scheduling Thanks to AXMART® software, the actuator can be programmed to schedule up to 20 tasks weekly repeatable. The ac-tuator will become a stand-alone unit. For any further information, refer to the operation manual (reference DSBA3302)
16
33
TECHNICAL SPECIFICATIONS
1) The actuator tolerates voltage fluctuation of the electrical grid up to ± 10 % of its nominal system operating voltage 2) The actuator tolerates temporary overvoltages of the electrical grid
MT25 MT50 MT75
Installation � � �
Materials Housing: Aluminium + EPOXY coating
Drive: Steel + Zn treatment Shafts and screws : Stainless steel
Sealing IP68
Environment Both inside and outside (wet environments possible)
Operating temperature -20°C to +70°C
Operating altitude Altitude up to 2000m
Hygrometry maximum relative humidity 80% for temperatures up to 31°C decreasing line-arly to 50% relative humidity at 40°C
Pollution degree Applicable POLLUTION DEGREE of the intended environment is 2 (in most cases).
Weight 19kg
Mechanical specifications
Maximum torque 25Nm 50Nm 75Nm
Number of rotations / minute 22 13 9
Angular range 5 to 250 turns
Duty cycle 50%
Valve connection (ISO 5210) F07/F10
Drive (according ISO5210)
keyed bore Ø20mm (B3) as standard keyed bore Ø42mm & 48mm height (B1) with drive bush (option)
treaded valve stem Ø25mm (A) shaft with tenons Ø43mm (C)
Drive bush F07/F10 stem Ø25 max | Maximum height 185mm (500mm or 1000mm with optional stem cover)
Manual control Secured handwheel without clutching system
Electric connection 3 x ISO M20 and specific multipin connector
Technology of motors Brushless
Voltages1) 100V to 240V AC 50/60Hz and 100V to 300V DC 24V to 48V AC 50/60Hz and 24V to 72V DC
Overvoltage category2) TRANSIENT OVERVOLTAGES up to the levels of OVERVOLTAGE CATEGO-RY ll
Power 300W
Rated current 10 to 12A
Torque limiter Electronic
Number of feedback switches 2 (4 in option)
Limit switches maximum voltage 4 to 250V AC/DC (Overvoltage category II)
Limit switches maximum current 1mA to 5A max.
Anticondensation heaters 3 x 10W
Electrical specifications
Noise level 63db
17
34
Actuato
r type
Torque (N
m)
Mounting and
drive
Voltage
Valve stem cover
Wheel m
ultiplier
Feed
back red
uction
Duty cycle
Version
Op
tion g
roup
1
MT 75 . 4 A 1 1 1 . G 00 . XXX
A Display
B Local control keyboard
C LED board indicator
D Mechanical torque limiter
H Extra anticondensation heater
L Application with vibrations
T Counter clockwise closing
M Marine coating
00 3-modulating points + ON-OFF mode
11 4-wire control
F3 3-position
S2 Battery security system - normally closed
S3 Battery security system & 3-position NC
S5 Battery security system & 3-position NO
S4 Battery security system - normally open
PS Positioning and Battery security system
1 2 to 12 rotations
2 12 to 25 rotations
3 25 to 130 rotations
4 130 to 250 rotations
0 Without
1 500mm
2 1000mm
3 1500mm
1 Tenons 14 F07/F10
2 B3 Form F07/F10
(solid bush with Ø20 maximum bore)
3 B1 Form F07/F10
(solid bush with Ø42 maximum bore)
4
G 50%
H 80%
M 30%
A 100V to 240V 50Hz/ 60Hz
and 100V to 300V DC
B 24V to 48V 50Hz / 60HZ
and 24V to 72V DC
0 Without
1 with
18
DSBA3500 • Rév. 14/11/2017 68