msl975019a apply complex instrumental techniques

Upload: chaerulanwar554

Post on 07-Jul-2018

218 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/19/2019 MSL975019A Apply Complex Instrumental Techniques

    1/36

    MSL975019A Apply complex instrumental techniques

    Modification History Not applicable.

    Unit escriptor

    Unit escriptorThis unit of competency covers the ability to analyse samples using specialisedanalytical instruments that require highly developed technical skills to operateeffectively. Competency includes the ability to establish client needs forroutine and non-routine samples, optimising enterprise procedures andinstruments for specific samples, obtaining valid and reliable data andreporting test results. Personnel are required to recognise atypical testdata/results and troubleshoot common analytical procedure and equipment

    problems.

    Application of the Unit

    Application ofthe Unit This unit of competency is applicable to technical officers orking in all

    industry sectors, government agencies and research laboratories. !ll operations

    and analytical methods must comply ith relevant standards, appropriate procedures and/or enterprise requirements. !lthough a supervisor may notal ays be present, the technical officer ill follo standard operating

    procedures "#$Ps% that clearly describe the scope of permitted practiceincluding varying enterprise/test procedures and communicating results to

    people outside the laboratory.

    &ndustry representatives have provided case studies to illustrate the practicalapplication of this unit of competency and to sho its relevance in a orkplacesetting, at the end of this unit of competency under the section 'Thiscompetency in practice'.

    Licensing/Regulatory Information Not applicable.

  • 8/19/2019 MSL975019A Apply Complex Instrumental Techniques

    2/36

    MSL975019A Menerapkan teknik analisis instrumen

    Sejarah perubahan Tidak berlaku

    Deskripsi unit

    Deskripsi

    unit

    Unit kompetensi ini mencakup kemampuan untuk menganalisacontoh menggunakan instrumen analitik khusus yangmemerlukan keterampilan teknis yang benar-benar

    dikembangkan agar d apat beroperasi secara efektif. Kompetensimencakup kemampuan untuk menetapkan kebutuhanpelanggan untuk contoh rutin dan non-rutin, mengoptimalkanprosedur dan instrumen perusahaan untuk contoh tertentu,termasuk memperoleh data dan pelaporan hasil uji yang validdan andal. Personil diperlukan untuk mengenali data uji /hasil yang tidak sesuai dan memecahkan masalah proseduranalisis umum dan masalah peralatan.

    Penerapan unit

    Penerapan

    unit

    Unit kompetensi ini berlaku untuk petugas teknis yan g bekerjadi semua sektor industri, instansi pemerintah dan laboratoriumpenelitian. Semua operasional dan metode analisis h arus sesu aidengan standar yang terkait, prosedur yang tepat dan / ataupersyaratan perusahaan. Meskipun penyelia mungkin tidakselalu hadir, petugas teknis akan mengikuti proseduroperasional standar (SOP) yang secara jelas menggambarkanruang lingkup praktek yang diijinkan termasuk berbagaiprosedur perusahaan / pengujian dan memberitahukan hasiluji kepada personel di luar laboratorium.Perwakilan industri telah menyediakan studi kasus untukmenggambarkan aplikasi praktis dari unit kompetensi ini danmenunjukkan keterkaitannya dalam pengaturan tempat kerja.Studi kasus d apat di lihat di bagian akhir u nit kompetensi pada

    bagian ‘Praktek Kompetensi’.

    Informasi lisensi/peraturan

    Tidak berlaku.

  • 8/19/2019 MSL975019A Apply Complex Instrumental Techniques

    3/36

    !re"#equisites

    !rerequisite units

    MSL975009A Apply routine chromatographic techniques

    OR

    OR

    MSL975020A Apply routine spectrometric techniques AND

    AND

    MSL974003A Perform chemical tests !

    OR

    MSL974004A Perform foo" tests !

    OR

    MSL97400#A Perform $iological proce"ures

    MSL973007A Perform microscopic e%amination& an"

    MSL973004A Perform aseptic techniques

    AND

    MSL973002A Prepare 'or(ing solutions

    OR

    MSL97400)A Prepare , stan"ar"ise an" use solutions

    $mploya%ility S&ills 'nformation

    $mploya%ility S&ills This unit contains employability skills.

  • 8/19/2019 MSL975019A Apply Complex Instrumental Techniques

    4/36

    Pra-syarat

    unit pra-syarat

    MSL975009A Menerapkan teknik kromatograrutin ATAU

    ATAU

    MSL975020A Menerapkan teknik spektrometrirutin DAN

    DAN

    MSL974003A Melakukan pengujian dan prosedurkimia ATAU

    ATAUMSL974004A Melakukan Pengujian makanan

    ATAU

    ATAU

    MSL974006A Melakukan prosedur biologi

    MSL973007A Melakukan pemeriksaanmikroskopik, dan

    MSL973004A Melakukan teknik aseptik

    DAN

    MSL973002A Menyiapkan larutan kerja

    ATAU

    MSL974001A Menyiapakan, menstandarisasi danmenggunakan larutan.

  • 8/19/2019 MSL975019A Apply Complex Instrumental Techniques

    5/36

    Kelayakan kerja Unit ini berisi kelayakan kerja .

    Informasi kelayakan kerja$lements and !erformance (riteria !re"(ontent

    $lements descri%e theessential outcomes of aunit of competency)

    Performance criteria describe the performance needed todemonstrate achievement of the element. (here bold italicised te)tis used, further information is detailed in the required skills andkno ledge section and the range statement. !ssessment of

    performance is to be consistent ith the evidence guide.

  • 8/19/2019 MSL975019A Apply Complex Instrumental Techniques

    6/36

    Uraian awal elemen kompetensi dan kriteria unjuk kerjaElemen yangmenjelaskan

    manfaat dari unitkompetensi

    Kriteria unjuk kerja menjelaskan kinerja yangdibutuhkan untuk menunjukkan capaian elemen.

    Apabila digunakan tulisan cetak tebal dengan hurufmiring, maka informasi lebih lanjut diuraikan dalam

    bagian keterampilan dan pengetahuan yangdiperlukan serta dalam batasan variable. Penilaiankinerja harus konsisten dengan panduan penilaian.

  • 8/19/2019 MSL975019A Apply Complex Instrumental Techniques

    7/36

    $lements and !erformance (riteria

    $L$M$*+ !$#,-#MA*($ (#'+$#'A

    *. +stablish client needs

    and schedule analysis

    *.*. iaise ith client or sample provider to determine client needs

    and sample history*. . ecord sample description, compare ith specification and

    record and report discrepancies*. . &dentify non-routine samples and the possible need to vary

    enterprise procedures*.0. #eek advice from supervisor about any proposed variations and

    document all approved changes.*.1. #chedule analysis using enterprise procedures

    . Prepare samples andstandards

    .*. $btain a representative analytical portion of the laboratorysample

    . . Prepare sample in accordance ith testing requirements

    . . Prepare validation checks and/or calibration standards foranalytical portions

    .0. 2se specialised procedures for ultra-trace sample and standard preparation as required

    . #etup, optimiseinstrument and sub-systems

    .*. Perform pre-use and safety checks using enterprise procedures

    . . !ssemble appropriate instrument sub-systems to construct therequired analytical path

    . . #tart up and condition the instrument using enterprise procedures

    .0. Check and optimise each instrument sub-system

    .1. $ptimise instrumental parameters to suit sample and test

    requirements.3. Check calibration status of instrument and perform calibration

    using specified standards and procedures, if applicable0. Perform analysis 0.*. 4easure analyte response for standards, validation checks and

    samples0. . Conduct sufficient measurements to obtain reliable data0. . eturn instruments to standby or shutdo n condition as

    required1. Process and analyse data 1.*. Confirm data is the result of valid measurements

    1. . Perform required calculations and ensure results are consistentith standards or estimations and e)pectations

  • 8/19/2019 MSL975019A Apply Complex Instrumental Techniques

    8/36

    Elemen kompetensi dan kriteria unjuk kerja

    ELEMEN KOMPETENSI KRITERIA UNJUK KERJA

    1.Menetapkankebutuhan pelanggandan menganalisis

    jadwal

    1.1 Pelanggan atau penyedia contoh dikoordinasikanuntuk menentukan keperluan pelanggan danriwayat contoh.

    1.2 Deskripsi contoh dicatat, dibandingkan denganspesikasi dan dilaporkan perbedaannya.

    1.3 Contoh non-rutin dan kemungkinan mengubahprosedur perusahaan diidentikasi.

    1.4 Saran dari atasan diminta terkait perbedaan yang diusulkan dan semua perubahan dokumen yang disetujui.

    1.5 Jadwal dianalisis sesuai dengan prosedur

    perusahaan.2. Menyiapkan contoh

    dan standar2.1 Contoh laboratorium yang representatif diambil

    untuk keperluan analisis.2.2 Contoh disiapkan sesuai dengan persyaratan

    pengujian.2.3 Pengujian validasi dilakukan sebagai bagian dari

    pekerjaan analisis.2.4 Prosedur khusus digunakan untuk contoh ultra-

    renik dan preparasi standar, seperti yangdipersyaratkan.

    3. Mengatur,optimisasiinstrumen dan sub-sistem

    3.1 Pra penggunaan dan pemeriksaan keamanandilakukan sesuai dengan SOP.

    3.2 Komponen komponen instrumen dipasang sesuaidengan jalur analitis yan g diperlukan.

    3.3 Instrumen dihidupkan dan dikondisikan sesua idengan SOP.

    3.4 Tiap komponen istrumen diperiksa dan d ioptimalkan.3.5 Parameter instrumen dioptimalkan terhadap contoh

    sesuai dengan persyaratan pengujian.3.6 Status kalibrasi instrumen diperiksa dan jika perlu

    dikalibrasi menggunakan standar dan prosedur yangditetapkan.

    4. Melakukan Analisis 4.1 Respon analit diukur untuk standar, pemeriksaan validasi dan contoh.

    4.2 Pengukuran dilakukan untuk memperoleh data yangandal.

    4.3 Instrumen dikembalikan ke kondisi awal ataudimatikan, jika d iperlukan.

    4.4 Jika diperlukan, contoh laboratorium yang tidakterpakai/yang sudah dipreparasi disimpan untukacuan di kemudian hari.

    5. Proses dan analisisdata

    5.1 Data dikonrmasi sebagai hasil dari pengukuran yang valid.

    5.2 Perhitungan dilakukan dan hasilnya dipastikankonsisten dengan standar atau estimasi danekspektasi.

    5.3 Hasil dicatat dengan akurasi, presisi, ketidakpastian

  • 8/19/2019 MSL975019A Apply Complex Instrumental Techniques

    9/36

    dan satuan yang tepat.5.4 Kecenderungan data dan/atau hasil dianalisis dan

    dilaporkan kepada personel yang tepat apabiladitemukan data yan g tidak lazim.

    5.5 Masalah terkait prosedur dan peralatan yangmenyebabkan data tidak lazim ditemukan dandiatasi.

    $L$M$*+ !$#,-#MA*($ (#'+$#'A

    1. . ecord results ith the appropriate accuracy, precision,uncertainty and units

    1.0. !nalyse trends in data and/or results and report out ofspecification or atypical results promptly to appropriate

    personnel1.1. Troubleshoot analytical procedure or equipment problems hich

    have led to atypical data or results3. 4aintain a safe ork

    environment

    3.*. &dentify risks, ha5ards, safety equipment and control measures

    associated ith sample handling, preparation and analyticalmethod3. . 2se personal protective equipment and safety procedures

    specified for test method and materials to be tested3. . 4inimise the generation of astes and environmental impacts3.0. +nsure the safe disposal of laboratory astes3.1. Clean, care for and store equipment and consumables in

    accordance ith enterprise procedures6. 4aintain laboratory records 6.*. +nter approved data and results into laboratory information

    management system " &4#%6. . 4aintain equipment logs in accordance ith enterprise

    procedures6. . 4aintain security, integrity and traceability of samples and

    documentation6.0. Communicate results to appropriate personnel

  • 8/19/2019 MSL975019A Apply Complex Instrumental Techniques

    10/36

    ELEMEN KOMPETENSI KRITERIA UNJUK KERJA

    6. Menjaga lingkungankerja yang am an

    6.1.Risiko, bahaya, peralatan keselamatan dantindakan pengendalian diidentikasi terkait

    dengan penanganan contoh, penyiapan danmetode a nalisis.

    6.2.Alat pelindung diri dan prosedur keselamatan yang ditetapkan digunakan untuk metode

    pengujian dan bahan yang akan diuji.6.3.Limbah yang dihasilkan dan dampak terhadap

    lingkungan diminimalkan.6.4.Pemusnahan limbah laboratorium dipastikan

    keamanannya.6.5.Peralatan dan bahan habis pakai dibersihkan,

    dirawat dan disimpan sesuai dengan prosedurperusahaan.

    7. Memelihara catatanlaboratorium

    7.1 Data dan hasil yang disetujui dimasukkan dalamsistem manajemen informasi laboratorium.

    7.2 Catatan peralatan dipelihara sesuai denganprosedur perusahaan.

    7.3 Contoh dan dokumen dipastikan keamanan,integritas da n ketertelusuranny.

    7.4 Hasil analisis dikomunikasikan kepada personil

    yang tepat.

  • 8/19/2019 MSL975019A Apply Complex Instrumental Techniques

    11/36

    #equired S&ills and .no/led e

    #$ U'#$ S.'LLS A* .*-2L$ 3$

    This section describes the skills and kno ledge required for this unit.

    #equired s&ills

    equired skills include78 establishing client needs for routine and non-routine samples8 interpreting client request, test methods and procedures accurately8 preparing samples and standards optimise procedures and equipment to suit sample/test

    requirements8 safely setting up, starting up and shutting do n equipment8 obtaining valid and reliable data8 troubleshooting common analytical procedure and equipment problems8 assembling checks and optimising instrument sub-systems8 checking the calibration/qualification status of equipment8 operating equipment to obtain valid and reliable data8 calculating analyte concentrations ith appropriate accuracy, precision, uncertainty and

    units8 recognising atypical data/results8 applying theoretical kno ledge to interpret data and make relevant conclusions8 recording and reporting data/results using enterprise procedures8 maintaining security, integrity and traceability of samples and documentation8 follo ing occupational health and safety "$9#% procedures and principles of good

    laboratory practice ": P%

    #equired &no/led e

    equired kno ledge includes78 principles and concepts related to instrument operation, material preparation and testing,

    such as78 mechanisms for absorption/emission8 distinction bet een selective ion monitoring "#&4% and total ion current "T&C% mode in gaschromatographic mass spectroscopy ":C-4#%

    8 sequence of steps required for successful anode stripping voltameter "!#;%8 function of key components and sub-system of the instrument8 handling of ha5ardous chemicals and samples and/or the fragile/labile nature of biological

    material8 sample preparation procedures8 effects on outputs and results of modifying instrumental variables8 procedures for optimising instrument performance8 basic procedure and equipment troubleshooting techniques

  • 8/19/2019 MSL975019A Apply Complex Instrumental Techniques

    12/36

    Keterampilan dan pengetahuan yang diperlukan

    KETERAMPILAN DAN PENGETAHUAN YANG DIPERLUKAN

    Bagian ini menjelaskan keterampilan dan pengetahuan yang diperlukan untukunit ini.

    Keterampilan yang diperlukan

    Keterampilan yang diperlukan termasuk:8 Menetapkan kebutuhan pelanggan untuk contoh rutin dan non-rutin8 Menafsirkan permintaan pelanggan, metode u ji dan prosedur secara a kurat8 Menyiapkan contoh dan standar utuk mengoptimalkan prosedur dan

    peralatan yang sesuai dengan contoh / persyaratan pengujian8 Mengatur, menghidupkan dan mematikan peralatan secara aman8 Memperoleh data yang valid dan dapat diandalkan8 Memecahkan masalah prosedur analisis umum dan masalah peralatan8 Mengecek pemasangan dan pengoptimisasian sub-sistem instrumen8 Memeriksa st atus k alibrasi / kualikasi peralatan8 Mengoperasikan peralatan untuk mendapatkan data yang valid dan dapat

    diandalkan8 Menghitung konsentrasi analit dengan akurasi, presisi, ketidakpastian dan

    satuan yang tepat8 Mengenali data/hasil yang tidak sesuai

    8 menerapkan pengetahuan teoritis untuk menginterpretasikan data danmembuat kesimpulan yang sesuai

    8 Merekam dan melaporkan data / hasil menggunakan prosedur perusahaan8 Menjaga keamanan, integritas dan ketertelusuran contoh dan dokumen• Mengikuti prosedur kesehatan dan keselamatan kerja (K3) dan prinsip-

    prinsip good laboratory practice (GLP)Pengetahuan yang diperlukan

    Pengetahuan yang diperlukan termasuk:8 Prinsip dan konsep yang berkaitan dengan pengoperasian instrumen,

    persiapan bahan dan pengujian, seperti:8 mekanisme penyerapan / emisi8 perbedaan antara mode selective ion monitoring (SIM) dan total i on

    current (TIC) pada kromatogra gas spektroskopi massa (KG-SM)8 Urutan langkah yang diperlukan untuk anode st ripping voltameter (ASV)8 Fungsi dari komponen kunci dan sub-sistem instrumen8 Penanganan bahan kimia dan contoh berbahaya dan / atau bahan biologis

    yang bersifat sifat rapuh / tidak stabil8 Prosedur persiapan contoh8 Efek pada output dan hasil dari modikasi variable instrumen8 Prosedur untuk optimisasi kinerja instrumen• Prosedur dasar dan Teknik troubleshooting peralatan

  • 8/19/2019 MSL975019A Apply Complex Instrumental Techniques

    13/36

    #$ U'#$ S.'LLS A* .*-2L$ 3$

  • 8/19/2019 MSL975019A Apply Complex Instrumental Techniques

    14/36

    KETERAMPILAN DAN PENGETAHUAN YANG DIPERLUKAN

    Keterampilan dan pengetahuan yang diperlukan termasuk:8 Penyusunan dan penggunaan kurva dan / at au standar kalibrasi

    8 Langkah-langkah perhitungan untuk memberikan hasil dalam satuan danpresisi yang tepat

    8 Prosedur dasar pemeliharaan peralatan8 Persyaratan perusahaan dan / at au ketertelusuran hukum• Persyaratan kesehatan, keselamatan dan lingkungan yang relevan

  • 8/19/2019 MSL975019A Apply Complex Instrumental Techniques

    15/36

    $4idence 3uide

    $ ' $*($ 3U' $

    The +vidence :uide provides advice on assessment and must be read in con=unction ith the performance criteria, required skills and kno ledge, range statement and the !ssessment:uidelines for the Training Package.

    -4er4ie/ of assessment

    (ritical aspects for assessmentand e4idence required todemonstrate competency in thisunit)

    !ssessors should ensure that candidates can78 interpret client request, test methods and procedures

    accurately8 safely set up, start up and shut do n equipment using

    enterprise procedures

    8 assemble checks and optimise instrument sub-systems8 check calibration/qualification status of equipment8 prepare samples and standards appropriately8 optimise procedures and equipment to suit sample/test

    requirements8 operate equipment to obtain valid and reliable data8 calculate analyte concentrations ith appropriate

    accuracy, precision and units8 recognise atypical data/results8 troubleshoot common analytical procedure and

    equipment problems

    8 apply theoretical kno ledge to interpret data andmake relevant conclusions8 record and report data/results using enterprise

    procedures8 maintain security, integrity and traceability of

    samples and documentation8 follo $9# procedures and principles of : P.

    (ontext of and specific resourcesfor assessment

    This unit of competency is to be assessed in the orkplaceor simulated orkplace environment.

    This unit of competency may be assessed ith7

    8 4# > 1??* !nalyse data and report results.esources may include7

    8 standard laboratory ith specialised analyticalinstruments

    8 laboratory reagents and equipment8 #$Ps and test methods.

  • 8/19/2019 MSL975019A Apply Complex Instrumental Techniques

    16/36

    Panduan penilaian

    PANDUAN PENILAIAN

    Panduan penilaian memberikan petunjuk tentang asesmen dan harus dibacadalam kaitannya dengan kriteria unjuk kerja, keterampilan dan pengetahuan

    yang diperlukan, batasan variabel dan pedoman asesmen untuk paketpelatihan.

    Tinjauan asesmen

    Aspek penting dalamasesmen dan bukti yangdiperlukan untukmenunjukkan kompetensi

    pada unit ini.

    Asesor harus memastikan bahwa kandidatdapat:8 menafsirkan permintaan pelanggan, metode

    uji dan prosedur s ecara akurat;

    8 mengatur, menghidupkan dan mematikanperalatan menggunakan prosedurperusahaan secara aman;

    8 mengecek pemasangan danpengoptimisasian sub-sistem instrument;

    8 mengecek status kalibrasi/kualikasiperalatan;

    8 mempersiapkan contoh dan standar secaratepat;

    8 mengoptimalkan prosedur dan peralatan yang sesuai dengan contoh/persyaratan

    pengujian;8 mengoperasikan peralatan untuk

    mendapatkan data yang valid dan dapatdiandalkan;

    8 menghitung konsentrasi analit denganakurasi, presisi dan satuan yang tepat;

    8 mengenali d ata/hasil yang tidak sesuai;8 menyelesaikan masalah prosedur analisis

    umum dan masalah peralatan;8 menerapkan pengetahuan teoritis untukmenginterpretasikan data dan membuatkesimpulan yang relevan;

    8 merekam dan melaporkan data/hasildengan menggunakan prosedurperusahaan;

    8 menjaga keamanan, integritas danketertelusuran contoh dan dokumen;

    8 mengikuti prosedur K3 dan prinsip-prinsipGLP.

  • 8/19/2019 MSL975019A Apply Complex Instrumental Techniques

    17/36

    Konteks dan sumber dayaspesik untuk asesmen

    Unit kompetensi ini harus dinilai di t empatkerja atau simulasi lingkungan tempat kerja.Unit kompetensi ini dapat dinilai menggunakan:8 Data MSL925001 Mengnalisis data dan

    melaporkan hasil.

    Sumber daya dapat mencakup:8 laboratorium standar dengan instrumen

    analitis k husus8 pereaksi laboratorium dan peralatan8 SOP dan metode uji.

  • 8/19/2019 MSL975019A Apply Complex Instrumental Techniques

    18/36

    $ ' $*($ 3U' $

    Method of assessment The follo ing assessment methods are suggested78 revie of test data/results obtained by the candidate

    over time to ensure accuracy, consistency andtimeliness of results

    8 inspection of test records and enterprisedocumentation completed by the candidate

    8 observation of candidate using specialisedinstruments to measure analytes

    8 feedback from clients, peers and supervisors8 oral or ritten questioning of relevant chemical

    principles, concepts, analytical techniques andenterprise procedures.

    &n all cases, practical assessment should be supported byquestions to assess underpinning kno ledge and those

    aspects of competency hich are difficult to assess directly.(here applicable, reasonable ad=ustment must be made toork environments and training situations to accommodate

    ethnicity, age, gender, demographics and disability.!ccess must be provided to appropriate learning and/orassessment support hen required.The language, literacy and numeracy demands ofassessment should not be greater than those required toundertake the unit of competency in a ork likeenvironment.

    +his competency in practice &ndustry representatives have provided the case studies belo to illustrate the practical application of this unit ofcompetency and to sho its relevance in a orkplacesetting. $n4ironmental 61&f oysters and other shellfish accumulate significant levelsof heavy metals, they can represent a public health risk

    hen consumed by humans. !nalysis of heavy metalresidues requires digestion of the sample in a concentratedacid, typically nitric. The digest is diluted in ultra pure

    ater and analysed by standard addition and electrothermal

    atomic absorption spectroscopy "!!#% using a phosphatemodifier to reduce lead volatility. The technician must paycareful attention to the digestion process and to the idelyvarying absorbances that ill result from oysters of havingaccumulated different concentrations of residue.

  • 8/19/2019 MSL975019A Apply Complex Instrumental Techniques

    19/36

    PANDUAN PENILAIAN

    Metode asesmen Metode ases men berikut ini disarankan:8 mengkaji data uji / hasil yang d iperoleh oleh

    kandidat dari waktu ke waktu untukmemastikan akurasi, konsistensi danketepatan waktu hasil

    8 pemeriksaan rekaman pengujian dandokumen perusahaan yang diselesaikankandidat

    8 pengamatan terhadap kandidat yangmenggunakan instrumen khusus untukmengukur analit

    8 umpan balik dari pelanggan, rekan-rekandan penyelia

    8 pertanyaan lisan atau tertulis dari prinsip-prinsip kimia, ko nsep, t eknik analisis danprosedur perusahaan yang sesuai

    Dalam semua kasus, asesmen terhadap praktekharus didukung oleh pertanyaan untuk menilaipengetahuan dasar dan aspek-aspek darikompetensi yang su lit dinilai secara langsung.

    Jika memungkinkan, penyesuaian harus dibuat

    untuk situasi lingkungan kerja dan pelatihanagar mengakomodasi suku, umur, jeniskelamin, demogra dan disabilitas.

    Apabila diperlukan, akses harus tersedia untukdukungan pembelajaran dan/atau asesmen

    yang tepat. Tuntutan bahasa, membaca dan menghitung

    dari suatu asesmen tidak boleh lebih besar dari yang dibutuhkan untuk melakukan unit

    kompetensi di dalam lingkungan kerja.

  • 8/19/2019 MSL975019A Apply Complex Instrumental Techniques

    20/36

    Praktek kompetensi Perwakilan industri telah memberikan studikasus di bawah ini untuk menggambarkanaplikasi p raktis dari unit kompetensi ini danmenunjukkan keterkaitannya dalam pengaturantempat kerja.

    Lingkungan (1) Apabila tiram dan kerang lainnyamengakumulasi secara signikan kadar logam

    berat, maka mereka dapat mewakili risikokesehatan bila dikonsumsi oleh manusia.

    Analisis residu logam berat memerlukan asampekat dalam proses digest contoh, biasanyadigunakan nitrat. Digest dilakukan denganpengenceran dalam air sangat murni dandianalisis dengan penambahan standarmenggunakan spektroskopi serapan atomelectrothermal (SSA) dengan menggunakanfosfat modier untuk mengurangi volatilitas.

    Teknisi harus memperhatikan secara hati-hatiterhadap proses digest dan absorbansi yangsangat beragam yang akan dihasilkan daritiram yang memiliki akumulasi residukonsentrasi yang berbeda.

    $ ' $*($ 3U' $

    Manufacturin "1%+lectrothermal atomic absorption "!!% spectrophotometers are oneof the more common instruments for the analysis of microgram/litrelevels of metals. #etting up the instrument requires more skill andcare than a normal flame !!# instrument. @irstly, the technicianmust check the graphite tube for ear, replace it if necessary, andre-align it. The auto sampler delivery tube must also be checked for its alignment so that delivery of the micro-litre aliquots of solutionis accurate and precise. The technician must also make thestandards ith great attention to avoid contamination fromglass are and reagents.

    Manufacturin 68The physical and mechanical properties of metal alloys arecrucially dependent on their composition. Therefore, thecomposition of alloys must be checked carefully. (hile aciddissolution and analysis by flame !!# or &CP emissionspectroscopy is possible, one of the most common techniques usedis A-ray fluorescence "A @% because it does not have the samedemanding sample preparation requirements. A @ samples, after

    polishing to remove any surface defects, can be analysed directlyagainst reference standards of the same alloy. Control of instrument

    variables is critical in obtaining accurate results. This requires thetechnician to carefully optimise a number of components ithin theoverall instrument before conducting the analysis.

  • 8/19/2019 MSL975019A Apply Complex Instrumental Techniques

    21/36

    PANDUAN PENILAIAN

    Manufaktur (1)Spectrometer serapan atom Electrothermal (SSA)

    merupakan salah satu instrumen yang umumuntuk menganalisis kadar logam dalam satuanmikrogram/liter. Pengaturan instrumenmembutuhkan keterampilan dan perawatanlebih dibanding instrumen ame SSA biasa.Pertama, teknisi harus memeriksa tabung gratuntuk dipakai, ganti jika perlu, dan sesuaikankembali. Auto sampler delivery tube juga harusdiperiksa kesesuaiannya sehingga pengirimanmikro-liter larutan aliquot bisa akurat dantepat. Teknisi juga harus membuat standardengan dengan sangat hati-hati untukmenghindari kontaminasi dari gelas dan reagen.

    Manufaktur (2)Sifat sik dan mekanik dari campuran logamtergantung pada komposisinya. Oleh karena itu,komposisi logam harus diperiksa dengan cermat.Sementara pelarutan asam dan analisis oleh

    ame SSA atau ICP spektroskopi emisimemungkinkan, salah satu teknik paling umum

    yang digunakan adalah X-ray uorescence(XRF)karena tidak mempersyaratkan persiapan contohsama. Contoh XRF, setelah diasah untukmenghilangkan cacat permukaan, contoh dapatdianalisis secara l angsung terhadap standar d aricampuran yang sama. Pengendalian variabelinstrumen penting dalam memperoleh hasil yang

    akurat. Hal ini memerlukan teknisi agar secar ahati-hati mengoptimisasi jumlah komponendalam instrumen secara keseluruhan sebelummelakukan analisis .

  • 8/19/2019 MSL975019A Apply Complex Instrumental Techniques

    22/36

    $ ' $*($ 3U' $

    $n4ironmental 68!n insurance company contracted a consulting laboratory toconduct tests on an accelerant residue that may have beenused in a recent arson attack on a local school building. Theresidue as run through a column chromatograph andcompared ith reference standards "such as petrol,kerosene, 1?B mi)tures, evaporated petrol% to establish theidentity of the sample. Confirmation of these results asobtained by using a :C-4# instrument to establish theidentity of the sample beyond reasonable doubt along ithadditional tests for heavy metals such as lead.

  • 8/19/2019 MSL975019A Apply Complex Instrumental Techniques

    23/36

    PANDUAN PENILAIAN

    Lingkungan (2)Sebuah perusahaan asuransi telah mengontrak

    konsultan laboratorium untuk melakukanpengujian pada residu accelerant yang mungkindigunakan pada serangan pembakaran

    bangunan sekolah setempat. Residu tersebutdiukur melalui kolom kromatogra dandibandingkan dengan standar acuan (seperti

    bensin, minyak tanah, 50% campuran, bensin yang diuapkan) untuk menentukan identitas

    contoh. Konrmasi hasil ini diperoleh denganmenggunakan instrumen KG-SM untukmenentukan identitas contoh bersama denganpengujian tambahan untuk logam berat sepertitimbal.

  • 8/19/2019 MSL975019A Apply Complex Instrumental Techniques

    24/36

    #an e Statement

    #A*3$ S+A+$M$*+

    The range statement relates to the unit of competency as a hole. &t allo s for different orkenvironments and situations that may affect performance. old italicised ording, if used in the performance criteria, is detailed belo . +ssential operating conditions that may be present ithtraining and assessment "depending on the ork situation, needs of the candidate, accessibility ofthe item, and local industry and regional conte)ts% may also be included.

    (odes of practice(here reference is made to industry codes of practice,and/or !ustralian/international standards, it is e)pected thelatest version ill be used

    Standards , codes , proceduresand /or enterprise requirements

    #tandards, codes, procedures and/or enterpriserequirements may include78 !ustralian and international standards, such as78 !# 1 iological safety cabinets8 !# $ *6? 1- ??1 :eneral requirements for the

    competence of testing and calibration laboratories8 !#/ND# 0 #et7 ??3 #afety in laboratories set8 !#/ND# >E .*7*>>6 aboratory design and

    construction-:eneral requirements8 !#/ND# $ *0??? #et7 ??1 +nvironmental

    management standards set

    8 !#/ND# $ >??? #et7 ??E Fuality managementsystems set8 !# E ?.* :ood laboratory practice - Chemical

    analysis8 !# *3 .* :eneral - ;olumetric glass are8 !# * 0.* @lame atomic absorption spectroscopy8 $/&+C :uide >E- 7 ??E 2ncertainty of

    measurement - Part :uide to the e)pression of uncertainty in measurement ":24%

    8 +urachem/C&T!C :uide C:0 Fuantifyinguncertainty in analytical measurement

    8 !ustralian code of good manufacturing practice for medicinal products ":4P%8 calibration and maintenance schedules8 cleaning, hygiene and personal hygiene

  • 8/19/2019 MSL975019A Apply Complex Instrumental Techniques

    25/36

    Batasan variabel

    BATASAN VARIABEL

    Batasan variabel berhubungan dengan unit kompetensi secara keseluruhan.Hal ini memungkinkan untuk lingkungan kerja dan situasi yang berbeda yangdapat mempengaruhi unjuk kerja. Tulisan bercetak tebal dengan huruf miring,

    jika digunakan dalam kriteria unjuk kerja diuraikan dibawah ini. Kondisipenting operasi yang mungkin ada pada pelatihan dan asesmen (tergantungdari situasi kerja, kebutuhan kandidat, aksesibilitas item , dan industri lokaldan konteks regional) juga dapat dimasukkan.

    Code of Pract ice Apabila referensi dibuat untuk Code of Practiceindustri, dan/atau standarnasional/internasional diharapkan

    menggunakan versi terbaru.Standar, norma, prosedur,dan/atau persyaratanperusahaan

    Standar, norma, prosedur dan/ataupersyaratan perusahaan dapat mencakup:8 standar nasional dan internasional, seperti:

    8 AS 2252 Biological safety cabinets8 SNI IEC 17025-2005 Persyaratan umum

    kompetensi untuk laboratorium pengujiandan kalibrasi

    8 WHO Third Edition 2004 Laboratorybiosafety manual

    8 AS / NZS 2982,1: 1997 Laboratorydesign and construction-Generalrequirements

    8 SNI 19-14001-2005 Sistem manajemenlingkungan- Persyaratan dan panduanpenggunaan

    • SNI ISO 9001:2008 Sistem manajemenmutu dan Persyaratan

    • SNI ISO 9000:2008 Sistem manajemen

    mutu - Dasar-dasar dan kosa kata• SNI ISO 9004:2009 Pengelolaan

    organisasi u ntuk sukses berkelanjutan-Pendekatan manajemen mutu

    8 SNI ISO 19011:2012 Panduan auditsistem manajemen (ISO 19011:2011, IDT )

    8 AS 2830.1 Good laboratory practice -Chemical analysis

    8 AS 2162.1 General - Volumetric glassware8 AS 2134.1 Flame atomic absorption

    spectroscopy8 ISO/IEC Guide 98-3:2008 Uncertainty of

    measurement - Part 3 Guide to theexpression of uncertainty in measurement(GUM)

    8 eurachem/CITAC Guide CG4 Quantifyinguncertainty in analytical measurement

  • 8/19/2019 MSL975019A Apply Complex Instrumental Techniques

    26/36

    8 pedoman Cara Pembuatan Obat yang Baik(CPOB)BPOM 2012

    8 jadwal kalibrasi dan pemeliharaan• persyaratan membersihkan, kebersihan dan

    kebersihan pribadi

  • 8/19/2019 MSL975019A Apply Complex Instrumental Techniques

    27/36

    #A*3$ S+A+$M$*+

    requirements8 data quality procedures8 enterprise procedures, #$Ps and operating manuals8 enterprise recording and reporting procedures8 equipment startup, operation and shutdo n procedures8 incident and accident/in=ury reports8 material safety data sheets "4#G#%8 material, production and product specifications8 national measurement regulations and guidelines8 principles of : P8 production and laboratory schedules8 quality manuals, equipment and procedure manuals8 quality system and continued improvement processes8 safety requirements for equipment, materials or

    products8 sampling procedures "labelling, preparation, storage,

    transport and disposal%8 schematics, ork flo s and laboratory layouts8 statutory and enterprise $9# requirements8 stock records and inventory8 test procedures "validated and authorised%8 training program contents8 aste minimisation, containment, processing and

    disposal procedures

    Specialised analytical instruments #pecialised analytical instruments may include7 8 spectrometric instruments such as7

    8 electrothermal "!!#%8 vapour generation "!!#%8 A-ray fluorescence "A @% and diffraction "A G%8 nuclear magnetic resonance "N4 %, magnetic

    resonance imaging "4 &%8 mass spectrometry "4#%8 neutron activation analysis "N!!%8 inductively coupled plasma mass

  • 8/19/2019 MSL975019A Apply Complex Instrumental Techniques

    28/36

    BATASAN VARIABEL

    8 prosedur kualitas d ata8 prosedur perusahaan, SOP dan manual

    operasional8 prosedur pencatatan dan pelaporan

    perusahaan8 prosedur menghidupkan, mengoperasikan

    dan mematikan alat8 laporan insiden dan kecelakaan / cedera8 lembar data keamanan bahan (MSDS)8 spesikasi bahan, produksi dan produk8 pedoman dan peraturan pengukuran

    nasional8 prinsip-prinsip GLP8 jadwal produksi dan laboratorium8 panduan mutu, manual peralatan dan

    prosedur8 sistem manajemen mutu dan proses

    peningkatan secara berkesinambungan8 persyaratan keselamatan untuk peralatan,

    bahan atau produk8 prosedur pengambilan contoh (pelabelan,

    persiapan, penyimpanan, transportasi danpembuangan)

    8 skema, alur kerja dan layout laboratorium8 hukum dan persyaratan K3 perusahaan8 catatan stok dan persediaan8 prosedur pen gujian (divalidasi dan disahkan)8 isi program pelatihan8 minimalisasi limbah, penampungan,

    prosedur pengolahan dan pembuangan

    Instrumen analitik Khusus Instrumen analitis kh usus da pat meliputi: 8 instrumen spektrometri seperti:

    8 electrothermal (AAS)8 vapour generation (AAS)8 X-ray uorescence (XRF) dan difraksi (XRD)8 nuclear magnetic resonance (NMR), magnetic

    resonance imaging (MRI)8 spektrometri massa (MS)

    8 neutron activation analysis (NAA)• inductively coupled plasma mass

  • 8/19/2019 MSL975019A Apply Complex Instrumental Techniques

    29/36

    #A*3$ S+A+$M$*+

    spectrometry "&CP-4#%8 chromatographic instruments such as7

    8 :C-4#8 :C sampling devices "e.g. headspace and thermal

    desorption%8 specialised :C detection devices "e.g. electron

    capture detector "+CG%, flame photometricdetector "@PG% and nitrogen phosphorousdetection "NPG%%

    8 specialised :C detection devices "e.g. fluorescent,diode array and electrochemical%

    8 liquid chromatography mass spectroscopy " C-4#%, electro-spray 4#

    8 gas chromatography fourier transform infra red":C-@T& %

    8 electrometric instruments, such as anodic strippingvoltammetry

    8 flo in=ection analytical equipment+ests requirin specialisedinstruments Tests requiring specialised instruments may include7

    8 trace analysis8 non-destructive testing8 multi-analyte determination8 analysis involving high sample throughput

    'nstrument su%"systems&nstrument sub-systems may include7

    8 sample introduction units and auto samplingequipment

    8 detectors and signal conditioning units8 temperature control devices such as cryostats, ovens,

    and thermostat baths8 soft are control/interface

    Sample preparation #ample preparation may include78 identification of any ha5ards associated ith the

    samples and/or analytical chemicals8 grinding, mulling, preparation of disks, digestion,

    dissolving, ashing, reflu)ing, e)traction, filtration,evaporation, flocculation, precipitation, ashing,drying and centrifugation

  • 8/19/2019 MSL975019A Apply Complex Instrumental Techniques

    30/36

    BATASAN VARIABEL

    spektrometri (ICP-MS)8 instrumen kromatogra seperti:

    8 KG-SM8 perangkat sampling KG (misalnya

    headspace dan desorpsi termal )8 Detektor KG khusus (misalnya elektron

    capture detector (ECD), detektor f otometrinyala (FPD) dan deteksi fosfor nitrogen(NPD))

    8 Detektor KG khusus (misalnya neon, diodaarray dan elektrokimia)

    8spektroskopi massa krom atogra cair (KC-SM), electro-spray MS

    8 gas ch romatography fourier transform infrared (GC-FTIR)

    8 instrumen electrometrik, seperti anodikstripping vo ltametri

    • peralatan analisis ow injectionPengujian yangmembutuhkan instrumenkhusus

    Pengujian yang membutuhkan instrumenkhusus dapat termasuk:

    8 analisis ren ik8 pengujian non-destruktif8 penentuan multi-analit8 analisis yang mencakup high sample

    throughputSub-sistem instrumen Sub-sistem instrumen dapat termasuk:

    8 unit pengenalan contoh dan peralatan autosampling

    8 unit detektor da n signal conditioning8 perangkat kontrol suhu seperti cryostats ,oven, dan thermostat baths

    8 kontrol perangkat l unak / interfacePersiapan contoh Persiapan contoh dapat termasuk:

    8 identikasi setiap bahaya yang terkaitdengan contoh dan / at au bahan kimiaanalitik

    8 penggilingan, mulling , persiapan disk , digesi,pelarutan, pengabuan, reuks, ekstraksi,penyaringan, penguapan, okulasi,pengendapan, pencucian, pengeringan dansentrifugasi

  • 8/19/2019 MSL975019A Apply Complex Instrumental Techniques

    31/36

    #A*3$ S+A+$M$*+

    8 solid-phase micro-e)traction8 determination of, and if appropriate, removal of any

    contaminants or impurities8 ultra-trace procedures requiring high purity solvents,

    clean rooms, ultra clean glass are and specialisedglass are

    (ommon analytical procedureand equipment pro%lems

    Common analytical procedure and equipment problemsmay include78 sample introduction blockages8 incomplete atomisation of analyte8 poor resolution of peaks8 poor sensitivity

    Ha ards 9a5ards may include7

    8 electric shock 8 bioha5ards7

    8 microbiological organisms and agents associatedith soil, air, ater, blood and blood products, and

    human or animal tissue and fluids8 mycoto)ins

    8 chemicals78 acids "e.g. sulphuric, perchloric and hydrofluoric%8 heavy metals and pesticides8 anions "e.g. fluoride%8 hydrocarbons "e.g. mono-aromatics%

    8 radiation "alpha, beta, gamma, A-ray and neutron%8 sharps and broken glass are8 aerosols from broken centrifuge tubes and pipetting8 flammable liquids and gases8 cryogenics such as dry ice and liquid nitrogen8 fluids under pressure such as hydrogen in gas liquid

    chromatography and acetylene in atomic absorptionspectrometry

    8 sources of ignition8 high temperature ashing processes8 disturbance or interruption of services

  • 8/19/2019 MSL975019A Apply Complex Instrumental Techniques

    32/36

    BATASAN VARIABEL

    8 solid-phase micro-extraction8 penentuan, dan jika sesu ai, penghilangan

    pengotor atau kemurnian8 Prosedur ultra-trace yang membutuhkan

    pelarut dengan kemurniannya tinggi,ruangan yang bersih, peralatan gelas yan gsangat bersih dan khusus

    Prosedur analisis umumdan masalah peralatan

    Prosedur analisis umum dan masalah peralatandapat mencakup:

    8 penyumbatan sample i ntroduction8 atomisasi dari analit yang tidak sempurna8 resolusi puncak yg rendah8 sensitivitas ya ng rendah

    Bahaya Bahaya dapat termasuk:

    8 sengatan listrik8 biohazards:

    8 organisme m ikrobiologi dan zat yangterkandung di tanah, udara, air, darahdan produk darah, dan jaringan manusia

    atau hewan dan cairan8 mikotoksin

    8 bahan kimia:8 Asam (misalnya sulfat, perklorat dan

    hidrouorida)8 logam berat dan pestisida8 anion (misalnya uoride)8 hidrokarbon (misalnya mono-aromatik)

    8 radiasi (alpha, beta, gamma, sinar-X dan

    neutron)8 benda tajam dan pecahan gelas8 aerosol dari tabung cen trifuge yan g pecah

    dan pemipetan8 cairan dan gas mudah terbakar8 cryogenics sep erti es k ering dan nitrogen

    cair8 cairan di bawah tekanan seperti hidrogen

    dalam kromatogra cair gas dan asetilenadalam spektrometri serapan atom

    8 sumber nyala api8 proses pengabuan dengan suhu tinggi8 gangguan dan terhentinya layanan

  • 8/19/2019 MSL975019A Apply Complex Instrumental Techniques

    33/36

    #A*3$ S+A+$M$*+

    Addressin ha ards !ddressing ha5ards may include78 use of 4#G#8 labelling of samples, reagents, aliquoted samples and

    ha5ardous materials8 personal protective equipment such as gloves, safety

    glasses, and coveralls8 use of fumehoods, direct e)traction of vapours, gases8 use of appropriate equipment such as bioha5ard

    containers, laminar flo cabinets, Class &, && and &&& bioha5ard cabinets

    8 handling and storage of all ha5ardous materials andequipment in accordance ith labelling, 4#G# andmanufacturer's instructions

    8 minimising e)posure to radiation ionising such as lasers,

    electromagnetic and ultraviolet "2;% radiation-ccupational health and safety"-HS %and en4ironmentalmana ement requirements

    $9# and environmental management requirements78 all operations must comply ith enterprise $9# and

    environmental management requirements, hich may beimposed through state/territory or federal legislation -these requirements must not be compromised at any time

    8 all operations assume the potentially ha5ardous nature ofsamples and require standard precautions to be applied

    8 here relevant, users should access and apply currentindustry understanding of infection control issued by the

    National 9ealth and 4edical esearch Council

    "N94 C% and #tate and Territory Gepartments of 9ealth

    Unit Sector6s

    Unit Sector Testing

  • 8/19/2019 MSL975019A Apply Complex Instrumental Techniques

    34/36

    BATASAN VARIABEL

    Mengatasi bahaya Mengatasi bahaya bisa termasuk:

    8 penggunaan MSDS8 pelabelan contoh, reagen, contoh aliquot

    dan bahan berbahaya8 alat pelindung diri seperti sarung tangan,

    kacamata pelindung, dan pakaianpelindung

    8 penggunaan lemari asam, uap ekstraksilangsung, gas

    8 penggunaan peralatan yang sesu ai sepertikontainer Biohazard , lemari alir l aminar,Kelas I , II dan III lemari Biohazard

    8 penanganan dan penyimpanan semua bahan berbahaya dan peralatan sesuai

    dengan label, MSDS dan instruksi pabrik• meminimalkan paparan radiasi pengion

    seperti laser, elektromagnetik dan radiasiultraviolet (UV)

    Persyaratan manajemenkesehatan dan keselamatankerja (K3) dan lingkungan

    Persyaratan manajemen K3 dan lingkungan:

    8 semua kegiatan harus memenuhipersyaratan manajemen K3 dan lingkungan

    yang dapat diberlakukan sesuai denganperaturan perundangan negara/wilayah,persyaratan ini tidak boleh dikompromikan8 semua kegiatan dianggap berpotensi

    bahaya alami dari contoh dan memerlukanstandar pencegahan yang akan diterapkan8 bila relevan, pengguna sebaiknyamengakses dan menerapkan pemahamanindustri yang mutakhir d alam pengendalianinfeksi yang dikeluarkan oleh National Healthand Medical Research Council

    NHMRC dankementrian kesehatan dan dinas kesehatan

    Sektor unit

    Sektor unit Pengujian

  • 8/19/2019 MSL975019A Apply Complex Instrumental Techniques

    35/36

    (ompetency field

    (ompetency field

    (o"requisite units

    (o"requisite units

  • 8/19/2019 MSL975019A Apply Complex Instrumental Techniques

    36/36

    Bidang kompetensi

    Bidang kompetensi

    Unit t erkait

    Unit t erkait