Maipu Confidential & Proprietary Information Page 1 of 57 MP1800-3 Router Installation Manual Maipu Communication Technology Co., Ltd No. 16, Jiuxing Avenue Hi-Tech Park Chengdu, Sichuan Province P. R. China 610041 Tel: (86) 28-85148850, 85148041 Fax: (86) 28-85148948, 85148139 URL: http:// www.maipu.com Mail: [email protected]

Upload: habibtariq

Post on 18-Nov-2014

128 views

Category:

Documents


5 download

TRANSCRIPT

Page 1: MP1800-3 Install Manual

Maipu Confidential & Proprietary Information Page 1 of 57

MP1800-3 Router Installation Manual

Maipu Communication Technology Co., Ltd No. 16, Jiuxing Avenue Hi-Tech Park Chengdu, Sichuan Province P. R. China 610041 Tel: (86) 28-85148850, 85148041 Fax: (86) 28-85148948, 85148139 URL: http:// www.maipu.com Mail: [email protected]

Page 2: MP1800-3 Install Manual

Maipu Confidential & Proprietary Information Page 2 of 57

All rights reserved. Printed in the People’s Republic of China. No part of this document may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual or otherwise without the prior written consent of Maipu Communication Technology Co., Ltd. Maipu makes no representations or warranties with respect to this document contents and specifically disclaims any implied warranties of merchantability or fitness for any specific purpose. Further, Maipu reserves the right to revise this document and to make changes from time to time in its content without being obligated to notify any person of such revisions or changes. Maipu values and appreciates comments you may have concerning our products or this document. address comments to: Maipu Communication Technology Co., Ltd No. 16, Jiuxing Avenue, Hi-Tech Park Chengdu, Sichuan Province P. R. China 610041 Tel: (86) 28-85148850, 85148041 Fax: (86) 28-85148948, 85148139 URL: http:// www.maipu.com Mail: [email protected] All other products or services mentioned herein may be registered trademarks, trademarks, or service marks of their respective manufacturers, companies, or organizations.

Document History

Date Revision No. Description

19/11/2007 R1.0 The MP1800-3 Router Installation Manual provides technical information about installation issues of the router designed and developed by Maipu Communication Technology Co., Ltd

Page 3: MP1800-3 Install Manual

Maipu Confidential & Proprietary Information Page 3 of 57

Maipu Feedback Form Your opinion helps us improve the quality of our product documentation and offer better services. Fax your comments and suggestions to (86) 28-85148948, 85148139 or email to [email protected].

Document Title MP1800-3 ROUTER INSTALLATION MANUAL

Product Version

Document Revision Number

1.0

Presentation: (Introductions, procedures, illustrations, completeness, arrangement, appearance)

Good Fair Average Poor

Accessibility: (Contents, index, headings, numbering)

Good Fair Average Poor

Evaluate this document

Editorial: (Language, vocabulary, readability, clarity, technical accuracy, content)

Good Fair Average Poor

Your suggestions to improve the document

check suggestions to improve this document: Improve introduction Make more concise Improve Contents Add more step-by-step procedures/tutorials Improve arrangement Add more technical information Include images Make it less technical Add more detail Improve index

If you wish to be contacted, complete the following:

Name Company

Postcode Address

Telephone E-mail

Page 4: MP1800-3 Install Manual

Maipu Confidential & Proprietary Information Page 4 of 57

Contents

About Installation Manual .........................................................................6 Purpose .................................................................................................................6 How to Get in Touch ...............................................................................................6

Customer Support...................................................................................................................6 Documentation Support...........................................................................................................6

Overview.....................................................................................................7 Key Features..........................................................................................................8 Hardware.............................................................................................................10

Appearance...........................................................................................................................10 MP1800-3 Router Back Panel Interface...................................................................................13 MP1800-3 Router Front Panel Interface..................................................................................13

Product Functions .................................................................................................15

Modules.................................................................................................... 17 Sync/Async Serial Interface Module (SAE) Series.....................................................18

1-port High-speed V.24/V.35 Serial Module (1SAE).................................................................18 Channelized E1 Module (CE1) Series ......................................................................20

1-port Channelized E1 Module (1CE1) ....................................................................................20 Non-channelized E1 Module (E1) Series..................................................................21

1-port Non-channelized E1 Module (1E1)................................................................................21 Frequency-band MODEM M336 Series ....................................................................23

1-port 33.6K Frequency-band MODEM (1M336) .....................................................................23 Base-band MODEM (M128) Series..........................................................................25

1-port 128K Base-band MODEM (1M128)...............................................................................25 ISDN S/T Module (STA) Series...............................................................................27

1-port ISDN S/T Module (1 STA)............................................................................................27 ISDN (U) Series....................................................................................................28

1-port ISDN U Module (1U)....................................................................................................28 IP Module (VOP/VOS) Series..................................................................................30

1-port IP Phone Module (1VOP) .............................................................................................30 2-port IP Phone Module (2VOP) .............................................................................................31 1-port Switch IP Phone Module (1VOS) ..................................................................................32 1 1VOS Module & Indicator....................................................................................................32 2-port Switch IP Phone Module (2VOS) ..................................................................................34

Asynchronous Serial Port Module (A) Series ............................................................35

Page 5: MP1800-3 Install Manual

Maipu Confidential & Proprietary Information Page 5 of 57

8-port Asynchronous Serial port Module (8AX)........................................................................35

System Installation................................................................................. 37 Precautions ..........................................................................................................37

Environment Requirements....................................................................................................37 Check Routers & Accessories .................................................................................................40

Chassis Installation ...............................................................................................41 Tools & Equipment ................................................................................................................41 Machine Installation...............................................................................................................42 Connecting Power Supply ......................................................................................................46 Grounding Requirements.......................................................................................................47 Connecting Main Control Board Cable.....................................................................................47 Grounding Wire Connection ...................................................................................................48

Module Installation................................................................................................48 Connecting Back Panel ..........................................................................................................49 Hardware Installation ............................................................................................................49

Module Interface Cable Connection ........................................................................50 1SAE Module Interface Cable Connection................................................................................50 Connecting 1CE1/1E1 Module Cable.......................................................................................52 1M336 Module Cable Connection............................................................................................53 1M128 Module Cable Connection............................................................................................53 Connecting 1STA Module Cable..............................................................................................53 1U Module Cable Connection..................................................................................................53 Connecting 1VOP/2VOP Module Cable....................................................................................53 Connecting 1VOS/2VOS Module Cable....................................................................................54 Connecting 8AX Module Cable................................................................................................54

Interface Cable Signal............................................................................. 54

Ethernet Cable .....................................................................................................54 Console Port Cable................................................................................................56 RM2-1E1 & RM2-1CE1 Using RJ45-RJ45 Crossing Twisted-pair .................................57

Page 6: MP1800-3 Install Manual

MP1800-3 Router Installation Manual Version 1.3

Maipu Confidential & Proprietary Information Page 6 of 57

About Installation Manual

Purpose The MP1800-3 Router Installation Manual explains installation and other technical topics. The manual aims to help technicians and network managers install the product and get going with it quickly.

How to Get in Touch The following sections provide information on how to obtain support for the Maipu English documentation and Maipu products.

Customer Support If you have problems or questions regarding your product, contact us by e-mail at [email protected]. You can also call our Overseas Business Division over +86–28-85148850, 85148041, 85148050, 85148750, and 85148997.

Documentation Support Maipu Communication Technology Co., Ltd welcomes comments and suggestions on the document usefulness. For further queries or suggestions, contact us by e-mail [email protected] or fax comments to +86-28-85148948 or 85148139. You can visit our website at http://www.maipu.com, which comprises interesting subjects such as product knowledge base, sales & support, and the Maipu news.

Page 7: MP1800-3 Install Manual

Page 7 of 57

Overview

MP1800-3-8FE router integrates routing, switching, security, VoIP and

transmission functions improving businesses in terms of Multi-service

Edge-Intelligent Network (MeIN). It adopts fixed and modular structure,

and provides broadband-narrowband, multi-service and intelligent

solutions.

The router extends 64-byte 100Kpps packet-forwarding capability and

100M line rate switching capability from LAN-to-WAN. It can be used to

access multi-Ethernet nodes such as network ends, PC and video monitor

in finance, stocks, insurance and public sector industries.

MP1800-3-8FE router provides software features such as VoIP, VPN, MPLS,

multicast, MAC address binding, and access control and bandwidth

restriction. It provides backup schemes and QoS features. It can be widely

applied to multiple services such as data, video and voice.

MP1800-3-8FE router, combined with other Maipu routers, provides

complete WAN network solutions for operator, finance, public sector,

energy, transport, education and defense, and large and medium-scale

organizations.

Page 8: MP1800-3 Install Manual

Page 8 of 57

Key Features The router integrates routing, switching, security, voice, transmission, local

storage and wireless to realize intelligent network. The inbuilt intelligent switch,

firewall, VPN (including MPLS VPN, IPsec VPN and L2TP VPN), VoIP and

transmission service modules provide a powerful intelligent platform for

different service applications. The router extends Multi-service Edge-Intelligent

Network (MeIN) to improve business efficiency.

The router is cost-effective and supports expansion of WAN line bandwidth to

100M. MP1800-3-8FE router adopts the fast-forwarding engine technology. The

LAN-to-WAN 64-byte forwarding performance reaches 100Kpps (for more than

256 bytes, the line rate reaches 100M); the switching performance from LAN-

to-WAN reaches 100M line rate. It supports expanding the WAN line bandwidth

to 100M.

The router has high expansibility. It facilitates expansion of WAN interfaces

and VoIP to realize narrowband access. MP1800-3-8FE router integrates the

features of previous narrowband routers and provides two high-speed MIMs

and one VoIP slot to realize the expansion of private leased line, dialing backup

and VoIP.

The router provides multi-Ethernet access for expansion of broadband. It

realizes the high-bandwidth access of multi-Ethernet nodes such as network

ends, PC and video monitor so that users do not need to purchase Ethernet

switches. The network investments are saved, faults reduced, and 100M optic

fiber broadband access of carrier MSTP realized.

Ethernet interfaces adopt L3 technology for intelligent service control. WAN line

backup ensures that the services are not interrupted. MP1800-3-8FE router

realizes the WAN line backup of narrowband-to-narrowband, broadband-to-

broadband, narrowband-to-broadband as well as wire-to-wire in the future. It

is not required that the upper active/standby aggregation devices are one

device, which meets the redundant backup requirement of upper aggregation

devices and solves the problem that the switches with high-bandwidth

expanding capability cannot realize WAN backup.

Page 9: MP1800-3 Install Manual

Page 9 of 57

The router realizes load balance of multiple WAN lines. The access

nodes/network devices provide two or more routes to reach the same server at

the upper layer. The lower-level MP1800-3-8FE router can distribute traffic

among multiple routes for load balancing. When some route fails, the traffic

can be re-distributed on the remaining routes.

The router provides intelligent NMS for automatically diagnosing router faults

to realize zero-spot service. Inbuilt dial-up modem/console port is connected to

an external dial-up modem for remote login. Switch to remote configuration

mode via button. Then users and manufacturers can maintain devices

anywhere via telephone line dial-up to realize “zero-spot service”. MP1800-3-

8FE router supports Maipu intelligent NMS for diagnosing and fixing router

faults, automatically generating a record for users to query. It reduces

management and maintenance work of users.

The router has a variety software functions and supports MPLS protocols. It

supports L2TP and IPsec. The router adopts technologies to deploy different

VPN networks from L2 to L3. The router is inbuilt with firewall and provides

advanced security features such as ACL packet-filtering, NAT, authentication

audit, route verification, callback, and refusing service protection. It provides

integrated services and distinguished services, and supports ACR, FIFO, PQ,

CQ, FQ, CBWFQ, and LLQ to ensure differentiation of key services. It supports

the centralized network management modes of SHELL and SNMP (SNMP V3).

The router adopts English graphical Maipu Masterplan to realize cross-platform

and modular network management.

MP1800-3-8FE router is compatible with routers of other manufacturers. It

provides easy-to-use configuration interfaces and styles. The router complies

with RFC standards and recognized industry standards. The routers can be

inter-connected and communicate with network devices of other manufacturers.

MP1800-3-8FE has stable structure. It adopts 19” standard chassis (1U high),

which can be installed on standard rack. The router withstands earthquake,

high temperatures, and electromagnetic radiation. It is easy to install or

uninstall.

Page 10: MP1800-3 Install Manual

Page 10 of 57

Hardware Appearance

MP1800 series router appearance

Page 11: MP1800-3 Install Manual

Page 11 of 57

Indicators:

SYS & PWR & FAN (system, power supply and fan indicators):

SYS - System status indicator

Shining: Program loading

Shining slowly: Loading successfully

PWR - System power supply indicator

On - After power on

FAN – Fan indicator

On: Normal working

Off: Malfunction

SLOT2 (Slot 2 status indicator)

ACT: Data receiving/sending indicator

RDY: On - on line

SLOT1 (Slot 1 status indicator)

ACT: Data receiving/sending indicator

RDY: On: on line

SLOT 0 (Slot 0 status indicator)

ACT: Data receiving/sending indicator

RDY - on: on line

CONSOLE (console port)

TXD - console port data sending indicator

RXD - console port data receiving indicator

Page 12: MP1800-3 Install Manual

Page 12 of 57

FETH1 (WAN Ethernet 1)

100M - 10/100M Ethernet interface data rate indicator

On: 100M

Off: 10M

ACT - Ethernet interface data receiving/sending indicator

FETH0 (WAN Ethernet 0)

100M - 10/100M Ethernet interface data rate indicator

On: 100M

Off: 10M

ACT - Ethernet interface data receiving/sending indicator

Page 13: MP1800-3 Install Manual

Page 13 of 57

MP1800-3 Router Back Panel Interface

MP1800-3 router back panel interface configuration

MP1800-3 router back panel interface:

Interface Interface form Description Slot

ON/OFF Power supply switch - right OFF & left ON

INPUT AC 100-240V 1A input DC -40~-57V, 27W

SLOT2 (special) Bus slot VOP/VOS VoIP module

SLOT1 Decided by interface module

Bus slot MIM module

SLOT0 Decided by interface module

Bus slot MIM module

SLOT2 is VoIP module slot. It has inset VOP/VOS series VoIP card module.

SLOT1 and SLOT0 are MIM slots with modular design.

MP1800-3 Router Front Panel Interface

Page 14: MP1800-3 Install Manual

Page 14 of 57

MP1800-3 Router System

Item Description

Console port One (RJ45). Async DTE working mode

Ethernet interface Two 10/100M fast Ethernet interfaces (RJ45)

MIM slot Two MIM slots

Special slot One VOP/VOS slot

Processor High-speed RISC processor

FLASH 32Mbyte (MP1800)

SDRAM 128Mbyte (MP1800)

Dimension (W×D×H)

444mm × 318mm × 44.5mm

Weight 4.5 Kg

Power supply input voltage

DC, -40~-57V

Environment temperature

0~40℃

Environment humidity 10~90%. Non-condensing

Maximum power 27W±10% (MP1800)

Page 15: MP1800-3 Install Manual

Page 15 of 57

Product Functions Protocol & Service Description

Network protocol WAN supports: PPP PPP compression SLIP CSLIP protocol Frame relay Frame relay switching X.25 X.25 switching HDLC LAPB ISDN LAN is Ethernet supporting two kinds of link layer frame: Ethernet-II Ethernet-SNAP

Dialup network MODEM dialup (calling/callout) CALLBACK Dial-on-demand Dialup backup

Routing protocol Static routing Dynamic routing: RIPv1 RIPv2 OSPF BGP IRMP (compatible with CISCO EIGRP) SNSP (compatible with CISCO ODR) Dial-on-demand (DDR) Policy routing Multicast: IGMP PIM-SM PIM-DM DVMRP Hot backup: VRRP VBRP (compatible with CISCO HSRP)

Network service ARP Proxy ARP L2TP Configuration command level protection IP packet filter firewall IP UNNUMBERED IP policy routing

Page 16: MP1800-3 Install Manual

Page 16 of 57

DHCP relay PAP/CHAP check EASY IP NAT network conceal RADIUS check IPsec data encryption IKE GRE Load balance MPLS

QoS service PQ CQ WFQ CBWFQ LLQ WRED CAR

Network management SNMPv1, SNMPv2, SNMPv3 Supporting standard network management (compatible with CISCO) Local configuration via console port Local or remote login via local Telnet Configuration command security isolation function Chinese/English prompt and help information Detailed debugging information, for network malfunction elimination Login and manage other products by Telnet Download and upload configuration file and application program via FTP Download and upload configuration file and application program via TFTP Colorful debugging information support Support log function

Security IP packet filter firewall, PAP/CHAP, MD5, NAT, RADIUS, TACACS, IPsec data encryption

Page 17: MP1800-3 Install Manual

MP1800-3 Router Installation Manual

Page 17 of 57

Modules

MP1800-3 router is a modular router with three slots. The current

interface module provides:

1SAE

1CE1

1E1

1M336

1M128

1U

1VOP

2VOP

1VOS

2VOS

1ETE

1STA

Page 18: MP1800-3 Install Manual

MP1800-3 Router Installation Manual

Page 18 of 57

Sync/Async Serial Interface Module (SAE) Series 1-port High-speed V.24/V.35 Serial Module (1SAE) 1SAE module is used for MP1800-3 router. Its main function is to complete

data flow receiving and sending.

For sync port, 2.048Mbps in DCE mode and 8 Mbps in DTE mode. For

async port 115.2Kbps. The working mode by default is in sync mode. In

DTE mode, it uses clock from external DCE equipment such as external

sync modem. But in DCE mode, router provides clock.

1SAE Interface Module

1SAE interface module:

1-port high speed V.24/V.35 serial module (1SAE)

1SAE Module Connected Cable

1SAE module connected cable is V35 DTE and V24 DTE.

1SAE Interface Attr ibutes

1SAE module interface attributes is as table 2-1: Table 2-1 1-port high

speed V.24/V.35 serial module (1SAE) interface attributes

Description Attributes

Sync Async

Tie-in DB25-DB25 DB25-DB25

Interface standard & working V.24 V.35 EIA/TIA-232

Page 19: MP1800-3 Install Manual

MP1800-3 Router Installation Manual

Page 19 of 57

mode DTE DCE

DTE DCE

Minimum BR (bps) 1200 1200 300

Maximum BR (bps) 128K 8M 115.2K

Dialup Backup

Protocol & Service X25 HDLC PPP SLIP FR LAPB

HDLC PPP SLIP

Page 20: MP1800-3 Install Manual

MP1800-3 Router Installation Manual

Page 20 of 57

Channelized E1 Module (CE1) Series 1-port Channelized E1 Module (1CE1) The 1-port channelized E1 module provides multi-timeslot data flow port

with total bus transmission rate 1984K. When used as CE1 interface, it can

be divided into 1-31 timeslots, and each group works an interface after

binding.

1CE1 Interface Module & Indicator

1CE1 interface module:

1-port channelized E1 module (1CE1)

1-port channelized E1 module (1CE1) indicator:

LOS Lost indicator On: Cannot check sync signal Off: After sync

1CE1 Module Connected Cable

1CE1: BNC pin coaxial line and RJ45-RJ45 connected twisted-pair.

Page 21: MP1800-3 Install Manual

MP1800-3 Router Installation Manual

Page 21 of 57

1CE1 Module Interface Attr ibutes

Attributes Description

Interface BNC, RJ45 (can not be used at the same time)

Interface No. One group for each

Interface standard

G.703

Protocol PPP X.25 HDLC FR

Non-channelized E1 Module (E1) Series 1-port Non-channelized E1 Module (1E1) The 1-port non-channelized E1 module provides 2.048Mbit/s data

transmission port. E1 is same as CE1 interface, which can be divided into

32 timeslots physically.

The timeslot 0 of E1 can be used for data transmission in unframed mode

for 2M transparent transmissions.

Page 22: MP1800-3 Install Manual

MP1800-3 Router Installation Manual

Page 22 of 57

1E1 Module & Indicator

1E1 module:

1-port non-channelized E1 module (1E1)

1-port non-channelized E1 module (1E1) indicator:

LOS On: Transparent 2M transmission On: Non-transparent and cannot check frame sync signal Off: After sync

1E1 Interface Connected Cable

1E1 and BNC pin coaxial cable and RJ45-RJ45 connected twisted-pair.

1E1 Interface Attr ibutes

1-port non-channelized E1 (1E1) attributes:

Attributes Description

Interface BNC, RJ45 (cannot be used together)

Interface number 1 group

Interface standard G.703

Supported service

X.25 FR

Supported protocol

PPP HDLC

Page 23: MP1800-3 Install Manual

MP1800-3 Router Installation Manual

Page 23 of 57

Frequency-band MODEM M336 Series 1-port 33.6K Frequency-band MODEM (1M336) The 1-port 33.6K frequency-band MODEM works in sync or async mode.

1M336 Interface & Dialup DIP

1M336 interface module:

1-port 33.6K frequency-band MODEM (1M336)

1-port 33.6K frequency-band MODEM (1M336) DIP:

DIP switch configuration

Mode

1 2

Description

Frequency-band MODEM mode

OFF OFF LINE port is used as inbuilt frequency-band MODEM interface

Console port mode ON OFF LINE port is used as CONSOLE port Configure router via dialup remote login

Page 24: MP1800-3 Install Manual

MP1800-3 Router Installation Manual

Page 24 of 57

1M336 Interface Module Connected Cable

1M336 module connected cable is RJ45 (4, 5 signal wire) or RJ11

telephone line.

1M336 Interface Attr ibutes

1M336 interface attributes:

1-port 33.6K frequency-band MODEM (1M336) attributes:

Attributes Description

Tie-in RJ45

Interface number 1

Supported link protocol

PPP Frame relay X.25 HDLC

Supported network protocol

IP

Page 25: MP1800-3 Install Manual

MP1800-3 Router Installation Manual

Page 25 of 57

Base-band MODEM (M128) Series 1-port 128K Base-band MODEM (1M128)

1M128 Module, Indicator & DIP Switch

1M128 interface module:

1-port 128K base-band MODEM (1M128)

Indicators:

1-port 128K base-band MODEM (1M128) indicator:

ACT On: Link established

B1 B1 channel indicator Light on: When using channel B1, and rate is 64K

B2 B2 channel indicator Light on: When using channel B2, and the rate is 128K

DIP switch description is as table 2-9:

1-port 128K base-band MODEM (1M128) DIP:

DIP switch configuration Mode

1 2

Description

Loopback ON Reservation

Page 26: MP1800-3 Install Manual

MP1800-3 Router Installation Manual

Page 26 of 57

1M128 Module Connected Cable

1M128 module connected cable is RJ45 (4, 5 signal cable) or RJ11 line.

1M128 Interface Attr ibutes

1M128 interface attributes:

1-port 128K base-band MODEM (1M128) interface:

Attributes Description

Tie-in RJ45

Interface number 1

Supported link protocol

PPP Frame relay X.25 HDLC

Supported network protocol

IP

Page 27: MP1800-3 Install Manual

MP1800-3 Router Installation Manual

Page 27 of 57

ISDN S/T Module (STA) Series 1-port ISDN S/T Module (1 STA) 1-port ISDN S/T module provides 64K or 128K high-speed access and

backup.

1 STA Module & Indicator

1 STA module:

1-port ISDN S/T module (1 STA)

1-port ISDN S/T module (1 STA) indicator

ACT Activated indicator and it is on when operates normally

B1 B1 channel indicator, and it is on when using channel B1, with the rate of B1=64K or B1+B2=128K.

B2 B2 channel indicator, and it is on when using channel B2, with the rate of B2=64K or B1+B2=128K.

1 STA Module Connected Cable

1 STA cable is RJ45 connected Ethernet cable.

1 STA Module Interface Attr ibutes

1-port ISDN S/T module (1 STA) interface attributes:

Attributes Description

Plug RJ45

Plug number 1

Supported protocol

PPP

Page 28: MP1800-3 Install Manual

MP1800-3 Router Installation Manual

Page 28 of 57

ISDN (U) Series 1-port ISDN U Module (1U) 1-port ISDN U module connects DDN network and ISDN network. It will

not connect modem.

1U Module & Indicator

1U module:

1-port ISDN U module (1U)

Page 29: MP1800-3 Install Manual

MP1800-3 Router Installation Manual

Page 29 of 57

1-port ISDN U module (1U) indicator:

ACT The light shines after link establishes

B1 B1 channel indicator Light on: When using channel B1 and rate is 64K

B2 B2 channel indicator Light on: When using channel B2 and the rate is 128K

1-port ISDN U module (1U) DIP switch:

DIP switch configuration Mode

1 2

Description

Loopback ON Reservation

1U Module Connected Cable

1U module connected cable RJ45 (4, 5 signal cable) or RJ11 line.

1U Interface Attr ibutes

1-port ISDN U module (1U) interface attributes:

Attributes Description

Tie-in RJ45

Interface number 1

Supported link protocol PPP

Supported network protocol IP

Page 30: MP1800-3 Install Manual

MP1800-3 Router Installation Manual

Page 30 of 57

IP Module (VOP/VOS) Series 1-port IP Phone Module (1VOP) The 1-port IP phone module accesses any telephone via IP network. You

can easily make a free phone call via IP network.

1VOP Module Indicator

1VOP interface module:

1-port IP phone module (1VOP) indicator:

V1 IP phone module indicator. The light is on during the call.

V2 1VOP module may not have this light. If it has, the light will be not on.

1VOP Module Connected Cable

1VOP module connected cable is RJ45 (4, 5 signal cable) and RJ11 line.

Page 31: MP1800-3 Install Manual

MP1800-3 Router Installation Manual

Page 31 of 57

1VOP Interface Attr ibutes

1-port IP phone module (1VOP) interface attributes:

Attributes Description

Interface RJ45 jack

Interface No. 1

Supported protocol

H.225 H.245 RTP RTCP G.711 G.723 G.729

2-port IP Phone Module (2VOP) The 2-port IP phone module accesses any call in IP network via dialup.

You can make free phone call via IP network.

2VOP Module & Indicator

2VOP module:

2-port IP phone module (2VOP)

2-port IP phone module (2VOP) indicator:

V1 IP phone module indicator Light on: After pickup, during the call

V2 IP phone module indicator Light on: After pickup, during the call

Page 32: MP1800-3 Install Manual

MP1800-3 Router Installation Manual

Page 32 of 57

2VOP Module Connected Cable

2VOP module connected cable is RJ45 external cable.

2VOP Module Interface Attr ibutes

2-port IP phone module (2VOP) interface attributes:

Attributes Description

Interface RJ45 jack (two RJ11 plugs)

Interface No 2 (RJ11)

Supported protocol

H.225 H.245 RTP RTCP G.711 G.723 G.729

1-port Switch IP Phone Module (1VOS) The 1-port switch IP phone module accesses any phone in IP network via

dialup or second dialup. You can easily make free phone calls via IP

network.

1 1VOS Module & Indicator

1-port switch IP phone module (1VOS)

Page 33: MP1800-3 Install Manual

MP1800-3 Router Installation Manual

Page 33 of 57

The indicator description is as table 2-18: Table 2-18 1-port switch IP

phone module (1VOS) indicator

V1 IP phone module indicator. Light on: during the phone call.

V2 1VOS module may not have this lamp. Otherwise, the lamp will never be on.

1VOS Module Connected Cable

1VOS module connected cable is RJ45 (4, 5 signal cable) and RJ11 line.

1VOS Interface Attr ibutes

1-port switch IP phone module (1VOS) interface attributes:

Attributes Description

Interface RJ45 jack

Interface No. 1

Supported protocol

H.225 H.245 RTP RTCP G.711 G.723 G.729

Page 34: MP1800-3 Install Manual

MP1800-3 Router Installation Manual

Page 34 of 57

2-port Switch IP Phone Module (2VOS) The 2-port switch IP phone module accesses any phone in IP network via

dialup or second dialup. You can easily make free phone call via IP

network.

2VOS Module & Indicator

2VOS module:

2-port switch IP phone module (2VOS)

2-port switch IP phone module (2VOS) indicator: V1 IP phone module indicator.

Lamp on: During the phone call V2 IP phone module indicator.

Lamp on: During the phone call

2VOS Module Connected Cable

2VOS module connected is RJ45.

2VOS Module Interface Attr ibutes

2-port switch IP phone module (2VOS) interface attributes: Attributes Description

Interface RJ45 jack

Interface number 2 (RJ11)

Supported protocols H.225 H.245 RTP RTCP G.711 G.723 G.729

Page 35: MP1800-3 Install Manual

MP1800-3 Router Installation Manual

Page 35 of 57

Asynchronous Serial Port Module (A) Series 8-port Asynchronous Serial port Module (8AX) 8-port asynchronous serial port module is to receive and send the data

flow of 8-port synchronous interface. It can only run in the asynchronous

mode and the maximum rate reaches 115.2K.

8AX Interface Module

8AX interface module:

8AX Interface Module Connected Cable

The cables of 8AX module adopt 8-port asynchronous serial port cable.

8AX Module Interface Attr ibutes

8AX module interface attributes is as follows:

Attributes Description

Tie-in DB60

Interface standard RS-232

Minimum Baud rate (bps) 300

Maximum Baud rate (bps) 115.2K

Supported services

Connect to terminals (with the function of fixing terminal numbers) Connect to ATM Connect to PC working stations Connect to routers Connect to frequency-base or baseband modems Access PC or router dialing Other serial devices

Supported protocol X.25 HDLC

Page 36: MP1800-3 Install Manual

MP1800-3 Router Installation Manual

Page 36 of 57

PPP SLIP

Page 37: MP1800-3 Install Manual

MP1800-3 Router Installation Manual

Page 37 of 57

System Installation

Precautions

Read this manual

Place MP1800-3 on flat surface

Do not put heavy material on MP1800-3

Note that cable doesn’t support hot-swap

Use UPS

Ensure proper grounding

Environment Requirements

Operat ion Environment

To guarantee stable use of router, maintain stable temperature and

humidity in the equipment room. MP1800-3 router must be used indoor.

The requirements for the indoor environment are as follows:

Environment temperature: 0~40°C

Humidity: 10~90%, non-condensing

MP1800-3 router is configured with the cooling fan. The cooling theory is:

With the effect of the fan, the cold air enters the device from the right of

the chassis and drawn out from the left. In this way, the forced convection

is formed and the heat generated during device running is drawn out.

Page 38: MP1800-3 Install Manual

MP1800-3 Router Installation Manual

Page 38 of 57

Around the device, there must be 10cm space to ensure enough cooling

space. It is recommended to install MP1800-3 router on the 19” standard

cabinet. If there is no cabinet, the device also can be placed on the clean

plane horizontally. In the areas with hot summer, it is recommended to

install the air-conditioner.

Temperature & Humidi ty

To ensure the service quality and life of MP1800-3 router, it is

recommended to maintain a certain temperature and humidity in the

computer lab. If the humidity in the computer lab is high for long time, it

causes the poor insulation and even electricity leak of insulation materials

easily.

Sometimes, the mechanical performances of materials change and the

metal parts are corroded easily, too. If the relative humidity is too low,

insulation pads shrink, which causes the fastened screws loose. Meanwhile,

in dry environment, static electricity appears easily, which harms the

circuits on the router.

If the temperature is too high, the reliability of the router reduces greatly.

The long-time high temperature affects the life and speeds up the aging of

insulation materials.

The recommended temperature and humidity in equipment room: Temperature Relevant humidity Long-term Short-term Long-term Short-term

15℃-30℃ 0℃-40℃ 40%-65% 10%-90%

Measuring points of the working temperature and humidity of MP1800-3

router in the equipment room mean the values measured from the floor

above 1.5 m and 0.4 m from the front of the rack when there are no

protection boards.

The short-term working condition means less than 48h continuously and

less than 15 days for the annual total.

Extreme adverse working environment means the environment

temperature and humidity when the air-conditioning system in the

computer room fails. Each time the normal work should be recovered

within less than 5h

Page 39: MP1800-3 Install Manual

MP1800-3 Router Installation Manual

Page 39 of 57

Dust- f ree Environment

Dust is harmful for MP1800-3 router operation. Dust causes static

absorption, which makes the poor contact of metal pieces. Static

absorption appears especially when the temperature and humidity are

lower, which affects the device life and causes communication fault.

Anti-stat ic

MP1800-3 router takes lots of measures in anti-static, but when the static

exceeds a certain volume, the circuits even the whole monitor are

damaged.

For router communication, static electricity originates from external

electric field of high-pressure like electricity cables and thunders, and

internal system such as floor material and chassis structure. To prevent

the damage caused by the static, do as follows:

• Ensure proper equipment grounding

• Maintain dustproof room

• Keep suitable temperature & humidity

• Wear anti-static equipment

• Place the disassembled circuit board on the anti static workstation

and keep the face upturned or in the anti static bag

When viewing or removing the disassembled circuit board, touch the edge

of circuit board and avoid touching the components on the circuit board.

Anti- interference

The various interference sources no matter from the exterior of devices or

application systems or from the interior affect the devices through

capacitance coupling, inductance coupling, electromagnetic radiation,

public impedance (including grounding system) and lead (such as power

lines, signal lines and output lines).

Therefore, pay attention to the following:

Page 40: MP1800-3 Install Manual

MP1800-3 Router Installation Manual

Page 40 of 57

• Take anti-electric network interference for power system.

• The router working place had better not be used with the grounding

settings of power devices or anti-thunder grounding settings and

the distance between them had better be as long as possible.

• Be away from the strong power radio transmitters, radar

transmitter, and high frequency high-current equipments.

• Take electromagnetic shielding methods when necessary

Check Routers & Accessories After ensuring the installation environment requirements are met, you can

open the package. However, before installation, check whether the router

and the accessories are complete according to the purchase order.

If some goods are lost or damaged, please contact the dealer or salesman

at once.

During the check, place the device and accessories in the safe place to

prevent the device from falling down or impact; keep the device far from

the liquid and dust to prevent the device from being damaged.

When checking or moving the device, wear gloves to prevent the metal

parts from eroded by the sweat. Reserve the packing materials for future

packing and transporting.

Page 41: MP1800-3 Install Manual

MP1800-3 Router Installation Manual

Page 41 of 57

Router Basic Conf igurat ion & Accessor ies

The configured MP1800-3 router includes the following configuration and

accessories:

Title No Remarks

MP1800-3 1 Router chassis Power supply cable 1 DC/AC

Console port cable 1 RJ45-DB9 crossing cable Ethernet cable 2 Straight-through network cable Technical documents 1 Installation manual and configuration manual

(CD) Installation accessories 1 A pair of brackets and a set of screws

Product packaging 1 Including foam anti-shocking material and external packing box, plastic bag etc

Chassis Installation Tools & Equipment Tools

Screwdriver

Anti-static wear

Glove

Connected cable

Console port cable

Ethernet cable (MP1800-3 Ethernet cable is configured according to the

number of Ethernet modules)

Modular interface cable

Equipment

Ethernet 10 BASE-T HUB

Configuring terminal (can be PC)

Equipment for optional module

Page 42: MP1800-3 Install Manual

MP1800-3 Router Installation Manual

Page 42 of 57

Machine Installation MP1800-3 dimensions:

444mm × 318mm × 44.5mm (W×D×H)

Check the rack. Give enough empty slot space for equipment before

installation.

Use ruler or tapeline to measure space between installation hole center

distance and horizontal direction.

Page 43: MP1800-3 Install Manual

MP1800-3 Router Installation Manual

Page 43 of 57

Check the splint, bracket, float nut, fixed nut and empty baffle

Install equipment on rank splint and bracket. Install splint and bracket

in rank.

Splint or bracket installation

Check whether floating nut is installed. If not, inset it into hole.

Note: One device should be put on one splint or bracket. Do not keep

several devices together.

Page 44: MP1800-3 Install Manual

MP1800-3 Router Installation Manual

Page 44 of 57

Installing equipment on bracket

MP1800-3 installing to bracket

Wear gloves and ensure proper grounding

Put device on flat surface and aim at bracket installation hole to the

side hole and then use bolt to fix

Check whether the bracket is fixed and straight

Page 45: MP1800-3 Install Manual

MP1800-3 Router Installation Manual

Page 45 of 57

Installing MP1800-3 to rack

Installing MP1800-3 router to rack

Wear anti-static gloves and ensure proper grounding

Put device on flat surface and aim at bracket installation hole to the

side hole and then use bolt to fix

Operator should face the equipment to keep the device level with both

hands. Push device inside with hands.

Use fixed bolt to install device on the rack

Check whether device is fixed and straight

Check the space between installed devices, choose rack baffle to put

among the devices, and then use bolt to fix

To guarantee the radiation space among devices, leave 1U height

Page 46: MP1800-3 Install Manual

MP1800-3 Router Installation Manual

Page 46 of 57

Connecting Power Supply MP1800-3 router adopts stable switch power supply system and different

areas have different requirements for power supply.

DC Input power supply: -40~-57V

AC Input power supply: 100-240V 50/60Hz

Maximum power consumption:

27W±10% (MP1800)

Use the following power supply jack or multi-functional PC power supply.

The following is the suggested power supply jack.

Ground wire

Live wireNaught wire

Connecting power supply:

Switch off MP1800 and connect one side of power supply cable to the entry of

back panel of router, and another side to power supply jack.

Switch power supply on

Check whether power supply indicator of front panel is on, if not, repeat step

1 and step 2.

Page 47: MP1800-3 Install Manual

MP1800-3 Router Installation Manual

Page 47 of 57

Grounding Requirements

Grounding mode should be in accordance with the united grounding

requirement of working place, protection place and anti-thunder

grounding.

Grounding cable section area: grounding cable (section area is

according to maximum current load) should adopt (copper) lead, but

not nakedness lead. The united grounding resistance should be <5Ω.

Good power supply grounding

Connecting Main Control Board Cable This section explains the method of connecting MP1800-3 router control

board cable to network including connecting router console port.

Connect ing Console Port

MP1800-3 provides one EIA/TIA-232 async serial console port. The user

configures router via this port by adopting RS-232 serial character

terminal (normally it is a PC).

Step 1: Find a character terminal, and it can be standard terminal with

RS-232 serial or normal PC.

Step 2: After confirming either router or terminal is out of power

supply, connect RS-232 serial and console port via cables.

Page 48: MP1800-3 Install Manual

MP1800-3 Router Installation Manual

Page 48 of 57

Grounding Wire Connection Power supply yawp filter is configured at the input end of router power

supply and the center is connected with chassis. For external network

connection such as E1 interface, the grounding cable protects PSTN.

Connect this point and ground it by a thick cable with resistance not more

than 4Ω. If the router is installed on 19-inch standard rack, ground the

rack.

Module Installation The router adopts modular system structure and different kinds of

interface configuration.

Module installation:

Choose the module and interface

Inset module to slot. The module circuit board should inset to interface

card slot.

Push in the module close to back panel

Tighten the screw

Page 49: MP1800-3 Install Manual

MP1800-3 Router Installation Manual

Page 49 of 57

bolt module bolt hole MP1800-3 series router module installation

Connecting Back Panel Back panel wire connection includes Ethernet interface cable, WAN

sync/async cable connection.

Hardware Installation Switch OFF power supply

Connect one side of AC power supply cable to entry of router power

supply and another side to power supply jack

Configure the router via console port after first power on

Inset one side of configuration cable to console port and another side

to PC or terminal serial

Inset one side of Ethernet cable to LAN interface and another side to

LAN. Connect sync/async communication cable to router WAN Interface.

MP1800-3 sync/async interface works in the mode of V.24/V.35 and these

two modes are completed by V.24/V.35 button.

In V.24 mode, interface adopts standard RS232 cable connection.

Page 50: MP1800-3 Install Manual

MP1800-3 Router Installation Manual

Page 50 of 57

In V.35 mode, interface adopts special V.35DTE cable connection.

V.24/V.35 DTE cable

After cable connection, open the power supply switch for router

configuration.

Module Interface Cable Connection 1SAE Module Interface Cable Connection This section explains important points in 1SAE module and cable

connection.

Before connecting sync/async serial, ensure the type of equipment

connecting sync/async serial - which is sync/async, DTE/DCE. Access the

equipment required signal standard, baud rate and sync clock.

DTE, DCE

Sync/async serial usually accesses external Modem or TA (terminal

adapter) as dialup interface. Sync serial has two modes - DTE and DCE.

Router is used as DTE equipment.

Page 51: MP1800-3 Install Manual

MP1800-3 Router Installation Manual

Page 51 of 57

DTE and DCE equipment

Equipment type Interface type Typical equipment

DTE Pin type PC Router

DCE Hole type MODEM Multiplexer CSU/DU

Rate and transmission distance:

Sync/async serial supports different signal standards and baud rate in

different working modes. Choose cables according to prevailing conditions.

V.24 cable rate and transmission distance:

BR (bps) Maximum transmission distance (m)

2400 60

4800 60

9600 30

19200 30

38400 20

64000 20

115200 10

V.35 cable rate and transmission distance:

BR (bps) Maximum transmission distance (m)

2400 1250

4800 625

9600 312

19200 156

38400 78

56000 60

64000 50

2048000 30

When adopting EIA/TIA-232 cable, BR rate cannot be over 64Kbps.

Page 52: MP1800-3 Install Manual

MP1800-3 Router Installation Manual

Page 52 of 57

Connect ing 1SAE Module Cable

Inset one side of DB-25 to 1SAE module DB-25 interface and then screw down

fixed knob.

Connect another DB25 interface to V.24-V.35 (DB-25, M-34) cable and then

connect to the following equipment:

If WAN is DDN line, connect (V.35 cable) to digital Modem V.35

interface. If WAN is dialup line, connect (V.24 cable) to analog Modem

serial.

Connecting 1CE1/1E1 Module Cable

Connect one side of BNC plug to BNC interface of 1CE1/E1 module.

Connect another side to relevant equipment.

TX should be connected with the RX equipment, and RX should be

connected with TX line.

Switch power on and check LOS status of 1CE1/E1 module. If lamp is

on, there is malfunction and signal loses sync, so check the line.

If using RJ45 interface, connect with RJ45-RJ45 twisted-pair. BNC and

RJ45 cannot be used together.

Page 53: MP1800-3 Install Manual

MP1800-3 Router Installation Manual

Page 53 of 57

1M336 Module Cable Connection Inset RJ11 plug of 1M336 module cable to LINE jack.

1M128 Module Cable Connection Inset RJ11 plug of 1M336 module cable to LINE jack, and another side

with external wire.

After power on, check ACT status of 1M128 module, and if indicator is

not on, check the circuit.

Connecting 1STA Module Cable

Inset RJ45 plug of 1STA module cable to RJ45 jack

Connect another side of RJ45 plug to equipment wire

1U Module Cable Connection Inset RJ11 plug of 1U module cable to LINE jack, and another side with

external wire

After power on, check ACT status of 1U module, and if indicator is not

on, check the circuit.

Connecting 1VOP/2VOP Module Cable

Inset telephone line to RJ11/RJ45 interface of 1VOP/2VOP, and another

side to telephone.

When having the phone call, pay attention to the indicator of

1VOP/2VOP card back panel. The indicator and Active light should be

on.

Page 54: MP1800-3 Install Manual

MP1800-3 Router Installation Manual

Page 54 of 57

Connecting 1VOS/2VOS Module Cable

Inset telephone line to RJ11/RJ45 interface of 1VOS/2VOS and another

side to small switch or external junction box.

When having the phone call, pay attention to the indicator of

1VOS/2VOS card back panel. The indicator and Active light should be

on.

Connecting 8AX Module Cable

Inset the DB60 plug of 8AX module cable to the socket. Pay attention

to the positive and negative directions. Screw down the cable fixing

button to fix the cable on the 8AX module socket.

Connect another RJ45 interface of the cable to relevant equipment wire.

Interface Cable Signal

Ethernet Cable MP1800-3 Ethernet interface cable is 8-core non-screen twisted-pair.

Port1/2 is sending end and port 3/6 is receiving end.

RJ45 connected cable (type-5 twisted-pair) connection relation:

RJ45 Signal Direction RJ45 Description Length

1 TX+ —> 1

2 TX- —> 2

Twisted-pair 1

2m

Page 55: MP1800-3 Install Manual

MP1800-3 Router Installation Manual

Page 55 of 57

3 RX+ <— 3

6 RX- <— 6

Twisted-pair 2

4 --- --- 4

5 --- --- 5

Twisted-pair 3

7 --- --- 7

8 --- --- 8

Twisted-pair 4

Table A-2 RJ45 crossing cable (type-5 twisted-pair) connection relation

RJ45 Signal Direction RJ45 Description Length

1 TX+ —> 3

2 TX- —> 6 Twisted-pair 1

3 RX+ <— 1

6 RX- <— 2 Twisted-pair 2

4 --- --- 7

5 --- --- 8 Twisted-pair 3

7 --- --- 4

8 --- --- 5 Twisted-pair 4

2m

Page 56: MP1800-3 Install Manual

MP1800-3 Router Installation Manual

Page 56 of 57

Console Port Cable

MP1800-3 console port cable is connected with PC 9-core serial jack, and it

is 8-core non-screen cable. One side is RJ45 plug and another is DB9

(hole).

RJ45 jack Standard DB9 interface

Console port cable connection relation:

RJ45 Signal Direction DB9 Length

1 CTS —> 8

2 DSR —> 6

3 RXD —> 2

4 GND --- 5

5 --- --- ---

6 TXD <— 3

7 DTR <— 4

8 RTS <— 7

--- --- 1

--- --- 9

3m

4 3 2 1 8 7 6 5

Page 57: MP1800-3 Install Manual

MP1800-3 Router Installation Manual

Page 57 of 57

RM2-1E1 & RM2-1CE1 Using RJ45-RJ45 Crossing Twisted-pair

When using E1 card RJ45 interface, use RJ45-RJ45 crossing twisted-pair.

E1 and CE1 using RJ45-RJ45 crossing twisted-pair: RJ45 Signal Direction RJ45 1 RX+ <— 4 2 RX- <— 5 3 --- --- 7 6 --- --- 8 4 TX+ —> 1 5 TX- —> 2 7 --- --- 3 8 --- --- 6